All the vulnerabilites related to Siemens AG - SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)
cve-2019-19281
Vulnerability from cvelistv5
Published
2020-03-10 19:16
Modified
2024-08-05 02:09
Severity ?
Summary
A vulnerability has been identified in SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V2.5 and < V20.8), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.5 and < V2.8), SIMATIC S7-1500 Software Controller (All versions >= V2.5 and < V20.8). Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a Denial-of-Service condition. The vulnerability can be triggered if specially crafted UDP packets are sent to the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise the device availability.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T02:09:39.528Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-750824.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-11"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.5 and \u003c V20.8"
            }
          ]
        },
        {
          "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.5 and \u003c V2.8"
            }
          ]
        },
        {
          "product": "SIMATIC S7-1500 Software Controller",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.5 and \u003c V20.8"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003e= V2.5 and \u003c V20.8), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e= V2.5 and \u003c V2.8), SIMATIC S7-1500 Software Controller (All versions \u003e= V2.5 and \u003c V20.8). Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a Denial-of-Service condition. The vulnerability can be triggered if specially crafted UDP packets are sent to the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise the device availability."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-400",
              "description": "CWE-400: Uncontrolled Resource Consumption (\u0027Resource Exhaustion\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-04-02T21:49:46",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-750824.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-11"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2019-19281",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.5 and \u003c V20.8"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.5 and \u003c V2.8"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC S7-1500 Software Controller",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.5 and \u003c V20.8"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003e= V2.5 and \u003c V20.8), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e= V2.5 and \u003c V2.8), SIMATIC S7-1500 Software Controller (All versions \u003e= V2.5 and \u003c V20.8). Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a Denial-of-Service condition. The vulnerability can be triggered if specially crafted UDP packets are sent to the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise the device availability."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-400: Uncontrolled Resource Consumption (\u0027Resource Exhaustion\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-750824.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-750824.pdf"
            },
            {
              "name": "https://www.us-cert.gov/ics/advisories/icsa-20-042-11",
              "refsource": "MISC",
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-11"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2019-19281",
    "datePublished": "2020-03-10T19:16:17",
    "dateReserved": "2019-11-26T00:00:00",
    "dateUpdated": "2024-08-05T02:09:39.528Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}