All the vulnerabilites related to Siemens AG - SIMATIC WinCC (TIA Portal)
cve-2019-6576
Vulnerability from cvelistv5
Published
2019-05-14 19:54
Modified
2024-08-04 20:23
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). An attacker with network access to affected devices could potentially obtain a TLS session key. If the attacker is able to observe TLS traffic between a legitimate user and the device, then the attacker could decrypt the TLS traffic. The security vulnerability could be exploited by an attacker who has network access to the web interface of the device and who is able to observe TLS traffic between legitimate users and the web interface of the affected device. The vulnerability could impact the confidentiality of the communication between the affected device and a legitimate user. At the time of advisory publication no public exploitation of the security vulnerability was known.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf | x_refsource_MISC | |
http://www.securityfocus.com/bid/108412 | vdb-entry, x_refsource_BID | |
https://www.us-cert.gov/ics/advisories/ICSA-19-134-09 | x_refsource_MISC |
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T20:23:22.141Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf" }, { "name": "108412", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/108412" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-09" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC HMI Comfort Panels 4\" - 22\"", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 1" } ] }, { "product": "SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\"", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 1" } ] }, { "product": "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 1" } ] }, { "product": "SIMATIC WinCC Runtime Advanced", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 1" } ] }, { "product": "SIMATIC WinCC Runtime Professional", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 1" } ] }, { "product": "SIMATIC WinCC (TIA Portal)", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 1" } ] }, { "product": "SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions \u003c V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (All versions \u003c V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions \u003c V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions \u003c V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions \u003c V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions \u003c V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). An attacker with network access to affected devices could potentially obtain a TLS session key. If the attacker is able to observe TLS traffic between a legitimate user and the device, then the attacker could decrypt the TLS traffic. The security vulnerability could be exploited by an attacker who has network access to the web interface of the device and who is able to observe TLS traffic between legitimate users and the web interface of the affected device. The vulnerability could impact the confidentiality of the communication between the affected device and a legitimate user. At the time of advisory publication no public exploitation of the security vulnerability was known." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-310", "description": "CWE-310: Cryptographic Issues", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2019-10-24T15:26:04", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf" }, { "name": "108412", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/108412" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-09" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2019-6576", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC HMI Comfort Panels 4\" - 22\"", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 1" } ] } }, { "product_name": "SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\"", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 1" } ] } }, { "product_name": "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 1" } ] } }, { "product_name": "SIMATIC WinCC Runtime Advanced", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 1" } ] } }, { "product_name": "SIMATIC WinCC Runtime Professional", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 1" } ] } }, { "product_name": "SIMATIC WinCC (TIA Portal)", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 1" } ] } }, { "product_name": "SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)", "version": { "version_data": [ { "version_value": "All versions" } ] } } ] }, "vendor_name": "Siemens AG" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions \u003c V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (All versions \u003c V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions \u003c V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions \u003c V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions \u003c V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions \u003c V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). An attacker with network access to affected devices could potentially obtain a TLS session key. If the attacker is able to observe TLS traffic between a legitimate user and the device, then the attacker could decrypt the TLS traffic. The security vulnerability could be exploited by an attacker who has network access to the web interface of the device and who is able to observe TLS traffic between legitimate users and the web interface of the affected device. The vulnerability could impact the confidentiality of the communication between the affected device and a legitimate user. At the time of advisory publication no public exploitation of the security vulnerability was known." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-310: Cryptographic Issues" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf" }, { "name": "108412", "refsource": "BID", "url": "http://www.securityfocus.com/bid/108412" }, { "name": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-09", "refsource": "MISC", "url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-09" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2019-6576", "datePublished": "2019-05-14T19:54:48", "dateReserved": "2019-01-22T00:00:00", "dateUpdated": "2024-08-04T20:23:22.141Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-6577
Vulnerability from cvelistv5
Published
2019-05-14 19:54
Modified
2024-08-04 20:23
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server could allow Cross-Site Scripting (XSS) attacks if an attacker is able to modify particular parts of the device configuration via SNMP. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires system privileges and user interaction. An attacker could use the vulnerability to compromise confidentiality and the integrity of the affected system. At the stage of publishing this security advisory no public exploitation is known.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf | x_refsource_MISC | |
http://www.securityfocus.com/bid/108412 | vdb-entry, x_refsource_BID | |
https://www.us-cert.gov/ics/advisories/ICSA-19-134-09 | x_refsource_MISC |
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T20:23:22.189Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf" }, { "name": "108412", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/108412" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-09" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC HMI Comfort Panels 4\" - 22\"", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 1" } ] }, { "product": "SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\"", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 1" } ] }, { "product": "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 1" } ] }, { "product": "SIMATIC WinCC Runtime Advanced", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 1" } ] }, { "product": "SIMATIC WinCC Runtime Professional", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 1" } ] }, { "product": "SIMATIC WinCC (TIA Portal)", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 1" } ] }, { "product": "SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions \u003c V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (All versions \u003c V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions \u003c V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions \u003c V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions \u003c V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions \u003c V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server could allow Cross-Site Scripting (XSS) attacks if an attacker is able to modify particular parts of the device configuration via SNMP. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires system privileges and user interaction. An attacker could use the vulnerability to compromise confidentiality and the integrity of the affected system. At the stage of publishing this security advisory no public exploitation is known." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-80", "description": "CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2019-10-24T15:27:02", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf" }, { "name": "108412", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/108412" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-09" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2019-6577", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC HMI Comfort Panels 4\" - 22\"", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 1" } ] } }, { "product_name": "SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\"", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 1" } ] } }, { "product_name": "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 1" } ] } }, { "product_name": "SIMATIC WinCC Runtime Advanced", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 1" } ] } }, { "product_name": "SIMATIC WinCC Runtime Professional", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 1" } ] } }, { "product_name": "SIMATIC WinCC (TIA Portal)", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 1" } ] } }, { "product_name": "SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)", "version": { "version_data": [ { "version_value": "All versions" } ] } } ] }, "vendor_name": "Siemens AG" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions \u003c V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (All versions \u003c V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions \u003c V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions \u003c V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions \u003c V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions \u003c V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server could allow Cross-Site Scripting (XSS) attacks if an attacker is able to modify particular parts of the device configuration via SNMP. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires system privileges and user interaction. An attacker could use the vulnerability to compromise confidentiality and the integrity of the affected system. At the stage of publishing this security advisory no public exploitation is known." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf" }, { "name": "108412", "refsource": "BID", "url": "http://www.securityfocus.com/bid/108412" }, { "name": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-09", "refsource": "MISC", "url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-09" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2019-6577", "datePublished": "2019-05-14T19:54:48", "dateReserved": "2019-01-22T00:00:00", "dateUpdated": "2024-08-04T20:23:22.189Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-6572
Vulnerability from cvelistv5
Published
2019-05-14 19:54
Modified
2024-08-04 20:23
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The affected device offered SNMP read and write capacities with a publicly know hardcoded community string. The security vulnerability could be exploited by an attacker with network access to the affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf | x_refsource_MISC | |
http://www.securityfocus.com/bid/108412 | vdb-entry, x_refsource_BID | |
https://www.us-cert.gov/ics/advisories/ICSA-19-134-09 | x_refsource_MISC |
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T20:23:22.238Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf" }, { "name": "108412", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/108412" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-09" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC HMI Comfort Panels 4\" - 22\"", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 1" } ] }, { "product": "SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\"", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 1" } ] }, { "product": "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 1" } ] }, { "product": "SIMATIC WinCC Runtime Advanced", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 1" } ] }, { "product": "SIMATIC WinCC Runtime Professional", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 1" } ] }, { "product": "SIMATIC WinCC (TIA Portal)", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 1" } ] }, { "product": "SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions \u003c V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (All versions \u003c V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions \u003c V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions \u003c V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions \u003c V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions \u003c V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The affected device offered SNMP read and write capacities with a publicly know hardcoded community string. The security vulnerability could be exploited by an attacker with network access to the affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-200", "description": "CWE-200: Information Exposure", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2019-10-24T15:25:12", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf" }, { "name": "108412", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/108412" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-09" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2019-6572", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC HMI Comfort Panels 4\" - 22\"", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 1" } ] } }, { "product_name": "SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\"", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 1" } ] } }, { "product_name": "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 1" } ] } }, { "product_name": "SIMATIC WinCC Runtime Advanced", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 1" } ] } }, { "product_name": "SIMATIC WinCC Runtime Professional", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 1" } ] } }, { "product_name": "SIMATIC WinCC (TIA Portal)", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 1" } ] } }, { "product_name": "SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)", "version": { "version_data": [ { "version_value": "All versions" } ] } } ] }, "vendor_name": "Siemens AG" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions \u003c V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (All versions \u003c V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions \u003c V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions \u003c V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions \u003c V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions \u003c V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The affected device offered SNMP read and write capacities with a publicly know hardcoded community string. The security vulnerability could be exploited by an attacker with network access to the affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-200: Information Exposure" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf" }, { "name": "108412", "refsource": "BID", "url": "http://www.securityfocus.com/bid/108412" }, { "name": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-09", "refsource": "MISC", "url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-09" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2019-6572", "datePublished": "2019-05-14T19:54:48", "dateReserved": "2019-01-22T00:00:00", "dateUpdated": "2024-08-04T20:23:22.238Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }