Type a vendor name or a vulnerability id.



All the vulnerabilites related to Siemens AG - SIMATIC WinCC (TIA Portal) V13
cve-2019-10917
Vulnerability from cvelistv5
Published
2019-05-14 19:54
Modified
2024-08-04 22:40
Severity
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions < V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions < V7.5 Upd 3). An attacker with local access to the project file could cause a Denial-of-Service condition on the affected product while the project file is loaded. Successful exploitation requires access to the project file. An attacker could use the vulnerability to compromise availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T22:40:15.224Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-08"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SIMATIC PCS 7 V8.0 and earlier",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC PCS 7 V8.1",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.1 with WinCC V7.3 Upd 19"
            }
          ]
        },
        {
          "product": "SIMATIC PCS 7 V8.2",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd11"
            }
          ]
        },
        {
          "product": "SIMATIC PCS 7 V9.0",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC (TIA Portal) V13",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC (TIA Portal) V14",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14 SP1 Upd 9"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC (TIA Portal) V15",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1 Upd 3"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Runtime Professional V13",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Runtime Professional V14",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.1 Upd 8"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Runtime Professional V15",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1 Upd 3"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.2 and earlier",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.3",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.3 Upd 19"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.4",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.4 SP1 Upd 11"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.5",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.5 Upd 3"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions \u003c V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions \u003c V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions \u003c V7.5 Upd 3). An attacker with local access to the project file could cause a Denial-of-Service condition on the affected product while the project file is loaded. Successful exploitation requires access to the project file. An attacker could use the vulnerability to compromise availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-248",
              "description": "CWE-248: Uncaught Exception",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-10-23T19:28:02",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-08"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2019-10917",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC PCS 7 V8.0 and earlier",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC PCS 7 V8.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V8.1 with WinCC V7.3 Upd 19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC PCS 7 V8.2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd11"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC PCS 7 V9.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC (TIA Portal) V13",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC (TIA Portal) V14",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V14 SP1 Upd 9"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC (TIA Portal) V15",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V15.1 Upd 3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC Runtime Professional V13",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC Runtime Professional V14",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V14.1 Upd 8"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC Runtime Professional V15",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V15.1 Upd 3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC V7.2 and earlier",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC V7.3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.3 Upd 19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC V7.4",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.4 SP1 Upd 11"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC V7.5",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.5 Upd 3"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions \u003c V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions \u003c V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions \u003c V7.5 Upd 3). An attacker with local access to the project file could cause a Denial-of-Service condition on the affected product while the project file is loaded. Successful exploitation requires access to the project file. An attacker could use the vulnerability to compromise availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-248: Uncaught Exception"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf",
              "refsource": "CONFIRM",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf"
            },
            {
              "name": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-08",
              "refsource": "MISC",
              "url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-08"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2019-10917",
    "datePublished": "2019-05-14T19:54:48",
    "dateReserved": "2019-04-08T00:00:00",
    "dateUpdated": "2024-08-04T22:40:15.224Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2017-6865
Vulnerability from cvelistv5
Published
2017-05-11 10:00
Modified
2024-08-05 15:41
Severity
Summary
A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC Automation Tool (All versions < V3.0), SIMATIC NET PC-Software (All versions < V14 SP1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1), SIMATIC STEP 7 V5.X (All versions < V5.6), SIMATIC WinAC RTX 2010 SP2 (All versions), SIMATIC WinAC RTX F 2010 SP2 (All versions), SIMATIC WinCC (TIA Portal) V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1), SIMATIC WinCC V7.2 and prior (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Update 15), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd1), SIMATIC WinCC flexible 2008 (All versions < flexible 2008 SP5), SINAUT ST7CC (All versions installed in conjunction with SIMATIC WinCC < V7.3 Update 15), SINEMA Server (All versions < V14), SINUMERIK 808D Programming Tool (All versions < V4.7 SP4 HF2), SMART PC Access (All versions < V2.3), STEP 7 - Micro/WIN SMART (All versions < V2.3), Security Configuration Tool (SCT) (All versions < V5.0). Specially crafted PROFINET DCP broadcast packets sent to the affected products on a local Ethernet segment (Layer 2) could cause a Denial-of-Service condition of some services. The services require manual restart to recover.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T15:41:17.697Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-275839.pdf"
          },
          {
            "name": "98366",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "https://www.securityfocus.com/bid/98366"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Primary Setup Tool (PST)",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.2 HF1"
            }
          ]
        },
        {
          "product": "SIMATIC Automation Tool",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "product": "SIMATIC NET PC-Software",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14 SP1"
            }
          ]
        },
        {
          "product": "SIMATIC PCS 7 V8.1",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC PCS 7 V8.2",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.2 SP1"
            }
          ]
        },
        {
          "product": "SIMATIC STEP 7 (TIA Portal) V13",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13 SP2"
            }
          ]
        },
        {
          "product": "SIMATIC STEP 7 (TIA Portal) V14",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14 SP1"
            }
          ]
        },
        {
          "product": "SIMATIC STEP 7 V5.X",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.6"
            }
          ]
        },
        {
          "product": "SIMATIC WinAC RTX 2010 SP2",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC WinAC RTX F 2010 SP2",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC (TIA Portal) V13",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13 SP2"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC (TIA Portal) V14",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14 SP1"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.2 and prior",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.3",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.3 Update 15"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.4",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.4 SP1 Upd1"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC flexible 2008",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c flexible 2008 SP5"
            }
          ]
        },
        {
          "product": "SINAUT ST7CC",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions installed in conjunction with SIMATIC WinCC \u003c V7.3 Update 15"
            }
          ]
        },
        {
          "product": "SINEMA Server",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14"
            }
          ]
        },
        {
          "product": "SINUMERIK 808D Programming Tool",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 SP4 HF2"
            }
          ]
        },
        {
          "product": "SMART PC Access",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3"
            }
          ]
        },
        {
          "product": "STEP 7 - Micro/WIN SMART",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3"
            }
          ]
        },
        {
          "product": "Security Configuration Tool (SCT)",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.0"
            }
          ]
        },
        {
          "product": "Security Configuration Tool (SCT)",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.0"
            }
          ]
        }
      ],
      "datePublic": "2017-05-10T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Primary Setup Tool (PST) (All versions \u003c V4.2 HF1), SIMATIC Automation Tool (All versions \u003c V3.0), SIMATIC NET PC-Software (All versions \u003c V14 SP1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions \u003c V13 SP2), SIMATIC STEP 7 (TIA Portal) V14 (All versions \u003c V14 SP1), SIMATIC STEP 7 V5.X (All versions \u003c V5.6), SIMATIC WinAC RTX 2010 SP2 (All versions), SIMATIC WinAC RTX F 2010 SP2 (All versions), SIMATIC WinCC (TIA Portal) V13 (All versions \u003c V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions \u003c V14 SP1), SIMATIC WinCC V7.2 and prior (All versions), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Update 15), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Upd1), SIMATIC WinCC flexible 2008 (All versions \u003c flexible 2008 SP5), SINAUT ST7CC (All versions installed in conjunction with SIMATIC WinCC \u003c V7.3 Update 15), SINEMA Server (All versions \u003c V14), SINUMERIK 808D Programming Tool (All versions \u003c V4.7 SP4 HF2), SMART PC Access (All versions \u003c V2.3), STEP 7 - Micro/WIN SMART (All versions \u003c V2.3), Security Configuration Tool (SCT) (All versions \u003c V5.0). Specially crafted PROFINET DCP broadcast packets sent to the affected products on a local Ethernet segment (Layer 2) could cause a Denial-of-Service condition of some services. The services require manual restart to recover."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Other",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-03-21T15:44:20",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-275839.pdf"
        },
        {
          "name": "98366",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "https://www.securityfocus.com/bid/98366"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2017-6865",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Primary Setup Tool (PST)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.2 HF1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC Automation Tool",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC NET PC-Software",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V14 SP1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC PCS 7 V8.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC PCS 7 V8.2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V8.2 SP1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC STEP 7 (TIA Portal) V13",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V13 SP2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC STEP 7 (TIA Portal) V14",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V14 SP1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC STEP 7 V5.X",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V5.6"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC WinAC RTX 2010 SP2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC WinAC RTX F 2010 SP2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC WinCC (TIA Portal) V13",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V13 SP2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC WinCC (TIA Portal) V14",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V14 SP1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC WinCC V7.2 and prior",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC WinCC V7.3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.3 Update 15"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC WinCC V7.4",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.4 SP1 Upd1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC WinCC flexible 2008",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c flexible 2008 SP5"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SINAUT ST7CC",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions installed in conjunction with SIMATIC WinCC \u003c V7.3 Update 15"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SINEMA Server",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V14"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SINUMERIK 808D Programming Tool",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.7 SP4 HF2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SMART PC Access",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.3"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "STEP 7 - Micro/WIN SMART",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.3"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Security Configuration Tool (SCT)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V5.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Security Configuration Tool (SCT)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V5.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Primary Setup Tool (PST) (All versions \u003c V4.2 HF1), SIMATIC Automation Tool (All versions \u003c V3.0), SIMATIC NET PC-Software (All versions \u003c V14 SP1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions \u003c V13 SP2), SIMATIC STEP 7 (TIA Portal) V14 (All versions \u003c V14 SP1), SIMATIC STEP 7 V5.X (All versions \u003c V5.6), SIMATIC WinAC RTX 2010 SP2 (All versions), SIMATIC WinAC RTX F 2010 SP2 (All versions), SIMATIC WinCC (TIA Portal) V13 (All versions \u003c V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions \u003c V14 SP1), SIMATIC WinCC V7.2 and prior (All versions), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Update 15), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Upd1), SIMATIC WinCC flexible 2008 (All versions \u003c flexible 2008 SP5), SINAUT ST7CC (All versions installed in conjunction with SIMATIC WinCC \u003c V7.3 Update 15), SINEMA Server (All versions \u003c V14), SINUMERIK 808D Programming Tool (All versions \u003c V4.7 SP4 HF2), SMART PC Access (All versions \u003c V2.3), STEP 7 - Micro/WIN SMART (All versions \u003c V2.3), Security Configuration Tool (SCT) (All versions \u003c V5.0). Specially crafted PROFINET DCP broadcast packets sent to the affected products on a local Ethernet segment (Layer 2) could cause a Denial-of-Service condition of some services. The services require manual restart to recover."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Other"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-275839.pdf",
              "refsource": "CONFIRM",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-275839.pdf"
            },
            {
              "name": "98366",
              "refsource": "BID",
              "url": "https://www.securityfocus.com/bid/98366"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2017-6865",
    "datePublished": "2017-05-11T10:00:00",
    "dateReserved": "2017-03-13T00:00:00",
    "dateUpdated": "2024-08-05T15:41:17.697Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2019-10916
Vulnerability from cvelistv5
Published
2019-05-14 19:54
Modified
2024-08-04 22:40
Severity
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions < V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions < V7.5 Upd 3). An attacker with access to the project file could run arbitrary system commands with the privileges of the local database server. The vulnerability could be exploited by an attacker with access to the project file. The vulnerability does impact the confidentiality, integrity, and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T22:40:15.179Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-08"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SIMATIC PCS 7 V8.0 and earlier",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC PCS 7 V8.1",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.1 with WinCC V7.3 Upd 19"
            }
          ]
        },
        {
          "product": "SIMATIC PCS 7 V8.2",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd11"
            }
          ]
        },
        {
          "product": "SIMATIC PCS 7 V9.0",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC (TIA Portal) V13",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC (TIA Portal) V14",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14 SP1 Upd 9"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC (TIA Portal) V15",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1 Upd 3"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Runtime Professional V13",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Runtime Professional V14",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.1 Upd 8"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Runtime Professional V15",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1 Upd 3"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.2 and earlier",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.3",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.3 Upd 19"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.4",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.4 SP1 Upd 11"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.5",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.5 Upd 3"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions \u003c V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions \u003c V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions \u003c V7.5 Upd 3). An attacker with access to the project file could run arbitrary system commands with the privileges of the local database server. The vulnerability could be exploited by an attacker with access to the project file. The vulnerability does impact the confidentiality, integrity, and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-10-23T19:27:04",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-08"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2019-10916",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC PCS 7 V8.0 and earlier",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC PCS 7 V8.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V8.1 with WinCC V7.3 Upd 19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC PCS 7 V8.2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd11"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC PCS 7 V9.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC (TIA Portal) V13",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC (TIA Portal) V14",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V14 SP1 Upd 9"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC (TIA Portal) V15",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V15.1 Upd 3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC Runtime Professional V13",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC Runtime Professional V14",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V14.1 Upd 8"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC Runtime Professional V15",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V15.1 Upd 3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC V7.2 and earlier",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC V7.3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.3 Upd 19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC V7.4",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.4 SP1 Upd 11"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC V7.5",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.5 Upd 3"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions \u003c V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions \u003c V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions \u003c V7.5 Upd 3). An attacker with access to the project file could run arbitrary system commands with the privileges of the local database server. The vulnerability could be exploited by an attacker with access to the project file. The vulnerability does impact the confidentiality, integrity, and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf",
              "refsource": "CONFIRM",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf"
            },
            {
              "name": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-08",
              "refsource": "MISC",
              "url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-08"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2019-10916",
    "datePublished": "2019-05-14T19:54:48",
    "dateReserved": "2019-04-08T00:00:00",
    "dateUpdated": "2024-08-04T22:40:15.179Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2019-10918
Vulnerability from cvelistv5
Published
2019-05-14 19:54
Modified
2024-08-04 22:40
Severity
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions < V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions < V7.5 Upd 3). An authenticatd attacker with network access to the DCOM interface could execute arbitrary commands with SYSTEM privileges. The vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires authentication with a low-privileged user account and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T22:40:15.144Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-08"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SIMATIC PCS 7 V8.0 and earlier",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC PCS 7 V8.1",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.1 with WinCC V7.3 Upd 19"
            }
          ]
        },
        {
          "product": "SIMATIC PCS 7 V8.2",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd11"
            }
          ]
        },
        {
          "product": "SIMATIC PCS 7 V9.0",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC (TIA Portal) V13",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC (TIA Portal) V14",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14 SP1 Upd 9"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC (TIA Portal) V15",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1 Upd 3"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Runtime Professional V13",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Runtime Professional V14",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.1 Upd 8"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Runtime Professional V15",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1 Upd 3"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.2 and earlier",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.3",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.3 Upd 19"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.4",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.4 SP1 Upd 11"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.5",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.5 Upd 3"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions \u003c V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions \u003c V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions \u003c V7.5 Upd 3). An authenticatd attacker with network access to the DCOM interface could execute arbitrary commands with SYSTEM privileges. The vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires authentication with a low-privileged user account and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-749",
              "description": "CWE-749: Exposed Dangerous Method or Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-10-23T19:28:42",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-08"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2019-10918",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC PCS 7 V8.0 and earlier",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC PCS 7 V8.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V8.1 with WinCC V7.3 Upd 19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC PCS 7 V8.2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd11"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC PCS 7 V9.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC (TIA Portal) V13",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC (TIA Portal) V14",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V14 SP1 Upd 9"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC (TIA Portal) V15",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V15.1 Upd 3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC Runtime Professional V13",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC Runtime Professional V14",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V14.1 Upd 8"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC Runtime Professional V15",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V15.1 Upd 3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC V7.2 and earlier",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC V7.3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.3 Upd 19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC V7.4",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.4 SP1 Upd 11"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC V7.5",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.5 Upd 3"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions \u003c V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions \u003c V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions \u003c V7.5 Upd 3). An authenticatd attacker with network access to the DCOM interface could execute arbitrary commands with SYSTEM privileges. The vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires authentication with a low-privileged user account and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-749: Exposed Dangerous Method or Function"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf",
              "refsource": "CONFIRM",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf"
            },
            {
              "name": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-08",
              "refsource": "MISC",
              "url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-08"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2019-10918",
    "datePublished": "2019-05-14T19:54:48",
    "dateReserved": "2019-04-08T00:00:00",
    "dateUpdated": "2024-08-04T22:40:15.144Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}