Search criteria
2 vulnerabilities found for SIMATIC WinCC OA Operator iOS App by Siemens AG
CVE-2018-4847 (GCVE-0-2018-4847)
Vulnerability from cvelistv5 – Published: 2018-04-23 16:00 – Updated: 2024-09-17 02:57
VLAI?
Summary
A vulnerability has been identified in SIMATIC WinCC OA Operator iOS App (All versions < V1.4). Insufficient protection of sensitive information (e.g. session key for accessing server) in Siemens WinCC OA Operator iOS app could allow an attacker with physical access to the mobile device to read unencrypted data from the app's directory. Siemens provides mitigations to resolve the security issue.
Severity ?
No CVSS data available.
CWE
- CWE-538 - File and Directory Information Exposure
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Siemens AG | SIMATIC WinCC OA Operator iOS App |
Affected:
All versions < V1.4
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T05:18:26.463Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "103941",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/103941"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-597741.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SIMATIC WinCC OA Operator iOS App",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.4"
}
]
}
],
"datePublic": "2018-04-18T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC WinCC OA Operator iOS App (All versions \u003c V1.4). Insufficient protection of sensitive information (e.g. session key for accessing server) in Siemens WinCC OA Operator iOS app could allow an attacker with physical access to the mobile device to read unencrypted data from the app\u0027s directory. Siemens provides mitigations to resolve the security issue."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-538",
"description": "CWE-538: File and Directory Information Exposure",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-10-10T16:57:01",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"name": "103941",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/103941"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-597741.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"DATE_PUBLIC": "2018-04-18T00:00:00",
"ID": "CVE-2018-4847",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIMATIC WinCC OA Operator iOS App",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V1.4"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC WinCC OA Operator iOS App (All versions \u003c V1.4). Insufficient protection of sensitive information (e.g. session key for accessing server) in Siemens WinCC OA Operator iOS app could allow an attacker with physical access to the mobile device to read unencrypted data from the app\u0027s directory. Siemens provides mitigations to resolve the security issue."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-538: File and Directory Information Exposure"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "103941",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/103941"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-597741.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-597741.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2018-4847",
"datePublished": "2018-04-23T16:00:00Z",
"dateReserved": "2018-01-02T00:00:00",
"dateUpdated": "2024-09-17T02:57:39.805Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-4847 (GCVE-0-2018-4847)
Vulnerability from nvd – Published: 2018-04-23 16:00 – Updated: 2024-09-17 02:57
VLAI?
Summary
A vulnerability has been identified in SIMATIC WinCC OA Operator iOS App (All versions < V1.4). Insufficient protection of sensitive information (e.g. session key for accessing server) in Siemens WinCC OA Operator iOS app could allow an attacker with physical access to the mobile device to read unencrypted data from the app's directory. Siemens provides mitigations to resolve the security issue.
Severity ?
No CVSS data available.
CWE
- CWE-538 - File and Directory Information Exposure
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Siemens AG | SIMATIC WinCC OA Operator iOS App |
Affected:
All versions < V1.4
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T05:18:26.463Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "103941",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/103941"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-597741.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SIMATIC WinCC OA Operator iOS App",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.4"
}
]
}
],
"datePublic": "2018-04-18T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC WinCC OA Operator iOS App (All versions \u003c V1.4). Insufficient protection of sensitive information (e.g. session key for accessing server) in Siemens WinCC OA Operator iOS app could allow an attacker with physical access to the mobile device to read unencrypted data from the app\u0027s directory. Siemens provides mitigations to resolve the security issue."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-538",
"description": "CWE-538: File and Directory Information Exposure",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-10-10T16:57:01",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"name": "103941",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/103941"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-597741.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"DATE_PUBLIC": "2018-04-18T00:00:00",
"ID": "CVE-2018-4847",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIMATIC WinCC OA Operator iOS App",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V1.4"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC WinCC OA Operator iOS App (All versions \u003c V1.4). Insufficient protection of sensitive information (e.g. session key for accessing server) in Siemens WinCC OA Operator iOS app could allow an attacker with physical access to the mobile device to read unencrypted data from the app\u0027s directory. Siemens provides mitigations to resolve the security issue."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-538: File and Directory Information Exposure"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "103941",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/103941"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-597741.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-597741.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2018-4847",
"datePublished": "2018-04-23T16:00:00Z",
"dateReserved": "2018-01-02T00:00:00",
"dateUpdated": "2024-09-17T02:57:39.805Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}