All the vulnerabilites related to Siemens - SINAMICS PERFECT HARMONY GH180 Drives
cve-2020-15782
Vulnerability from cvelistv5
Published
2021-05-28 16:10
Modified
2024-08-04 13:22
Severity ?
Summary
A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SINAMICS PERFECT HARMONY GH180 Drives (Drives manufactured before 2021-08-13), SINUMERIK MC (All versions < V6.15), SINUMERIK ONE (All versions < V6.15). Affected devices are vulnerable to a memory protection bypass through a specific operation. A remote unauthenticated attacker with network access to port 102/tcp could potentially write arbitrary data and code to protected memory areas or read sensitive data to launch further attacks.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T13:22:30.758Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434534.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434536.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434535.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SIMATIC Drive Controller family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.2"
            }
          ]
        },
        {
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V21.9"
            }
          ]
        },
        {
          "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.5.0"
            }
          ]
        },
        {
          "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.2"
            }
          ]
        },
        {
          "product": "SIMATIC S7-1500 Software Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V21.9"
            }
          ]
        },
        {
          "product": "SIMATIC S7-PLCSIM Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.0"
            }
          ]
        },
        {
          "product": "SINAMICS PERFECT HARMONY GH180 Drives",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "Drives manufactured before 2021-08-13"
            }
          ]
        },
        {
          "product": "SINUMERIK MC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.15"
            }
          ]
        },
        {
          "product": "SINUMERIK ONE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.15"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC Drive Controller family (All versions \u003c V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V21.9), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003c V4.5.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V2.9.2), SIMATIC S7-1500 Software Controller (All versions \u003c V21.9), SIMATIC S7-PLCSIM Advanced (All versions \u003c V4.0), SINAMICS PERFECT HARMONY GH180 Drives (Drives manufactured before 2021-08-13), SINUMERIK MC (All versions \u003c V6.15), SINUMERIK ONE (All versions \u003c V6.15). Affected devices are vulnerable to a memory protection bypass through a specific operation. A remote unauthenticated attacker with network access to port 102/tcp could potentially write arbitrary data and code to protected memory areas or read sensitive data to launch further attacks."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-09-14T10:47:06",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434534.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434536.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434535.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2020-15782",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC Drive Controller family",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.9.2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V21.9"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.5.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.9.2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC S7-1500 Software Controller",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V21.9"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC S7-PLCSIM Advanced",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SINAMICS PERFECT HARMONY GH180 Drives",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Drives manufactured before 2021-08-13"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SINUMERIK MC",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V6.15"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SINUMERIK ONE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V6.15"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SIMATIC Drive Controller family (All versions \u003c V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V21.9), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003c V4.5.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V2.9.2), SIMATIC S7-1500 Software Controller (All versions \u003c V21.9), SIMATIC S7-PLCSIM Advanced (All versions \u003c V4.0), SINAMICS PERFECT HARMONY GH180 Drives (Drives manufactured before 2021-08-13), SINUMERIK MC (All versions \u003c V6.15), SINUMERIK ONE (All versions \u003c V6.15). Affected devices are vulnerable to a memory protection bypass through a specific operation. A remote unauthenticated attacker with network access to port 102/tcp could potentially write arbitrary data and code to protected memory areas or read sensitive data to launch further attacks."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-434534.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434534.pdf"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-434536.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434536.pdf"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-434535.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434535.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2020-15782",
    "datePublished": "2021-05-28T16:10:10",
    "dateReserved": "2020-07-15T00:00:00",
    "dateUpdated": "2024-08-04T13:22:30.758Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}