Type a vendor name or a vulnerability id.



All the vulnerabilites related to Siemens - SINAMICS S150 V4.7 w. PN
var-201712-0703
Vulnerability from variot

A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, SIMATIC Compact Field Unit, SIMATIC ET200AL, SIMATIC ET200M (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN BA (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN HF (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN ST (incl. SIPLUS variants), SIMATIC ET200S (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN BA (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HA (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HS (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN ST (incl. SIPLUS variants), SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 4AO U/I 4xM12, SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12, SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12, SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN: IO-Link Master, SIMATIC ET200pro, SIMATIC PN/PN Coupler (incl. SIPLUS NET variants), SIMATIC S7-1200 CPU family (incl. SIPLUS variants), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-1500 Software Controller, SIMATIC S7-200 SMART, SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-400 H V6 CPU family and below (incl. SIPLUS variants), SIMATIC S7-400 PN/DP V6 CPU family and below (incl. SIPLUS variants), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants), SIMATIC TDC CP51M1, SIMATIC TDC CPU555, SIMATIC WinAC RTX (F) 2010, SIMOCODE pro V EIP (incl. SIPLUS variants), SIMOCODE pro V PN (incl. SIPLUS variants), SIMOTION C, SIMOTION D (incl. SIPLUS variants), SIMOTION D4xx V4.4 for SINAMICS SM150i-2 w. PROFINET (incl. SIPLUS variants), SIMOTION P V4.4 and V4.5, SIMOTION P V5, SINAMICS DCM w. PN, SINAMICS DCP w. PN, SINAMICS G110M w. PN, SINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants), SINAMICS G130 V4.7 w. PN, SINAMICS G130 V4.8 w. PN, SINAMICS G150 V4.7 w. PN, SINAMICS G150 V4.8 w. PN, SINAMICS GH150 V4.7 w. PROFINET, SINAMICS GL150 V4.7 w. PROFINET, SINAMICS GM150 V4.7 w. PROFINET, SINAMICS S110 w. PN, SINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants), SINAMICS S120 V4.7 w. PN (incl. SIPLUS variants), SINAMICS S120 V4.8 w. PN (incl. SIPLUS variants), SINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants), SINAMICS S150 V4.7 w. PN, SINAMICS S150 V4.8 w. PN, SINAMICS SL150 V4.7.0 w. PROFINET, SINAMICS SL150 V4.7.4 w. PROFINET, SINAMICS SL150 V4.7.5 w. PROFINET, SINAMICS SM120 V4.7 w. PROFINET, SINAMICS V90 w. PN, SINUMERIK 840D sl, SIRIUS Soft Starter 3RW44 PN. Specially crafted packets sent to port 161/udp could cause a Denial-of-Service condition. The affected devices must be restarted manually. plural Siemens The product contains data processing vulnerabilities.Service operation interruption (DoS) There is a possibility of being put into a state. SiemensSIMATICS7-200Smart and others are products of Siemens AG. The Siemens SIMATICS7-200Smart is a programmable logic controller (PLC) for use in small and medium-sized automation systems. SIMATICWinACRTX2010incl is a software controller for automation solutions. A denial of service vulnerability exists in several Siemens products. Attackers can exploit this issue to crash the affected device, denying service to legitimate users. A vulnerability has been identified in SIMATIC S7-200 Smart (All versions < V2.03.01), SIMATIC S7-400 PN V6 (All versions < V6.0.6), SIMATIC S7-400 H V6 (All versions < V6.0.8), SIMATIC S7-400 PN/DP V7 (All versions < V7.0.2), SIMATIC S7-410 V8 (All versions < V8.2.1), SIMATIC S7-300 (All versions < V3.X.16), SIMATIC S7-1200 (All versions < V4.2.3), SIMATIC S7-1500 (All versions < V2.0), SIMATIC S7-1500 Software Controller (All versions < V2.0), SIMATIC WinAC RTX 2010 incl. F (All versions), SIMATIC ET 200AL (All versions), SIMATIC ET 200ecoPN (All versions), SIMATIC ET 200M (All versions), SIMATIC ET 200MP IM155-5 PN BA (All versions < V4.0.2), SIMATIC ET 200MP IM155-5 PN ST (All versions < V4.1), SIMATIC ET 200MP IM155-5 PN HF (All versions < V4.2), SIMATIC ET 200pro (All versions), SIMATIC ET 200S (All versions), SIMATIC ET 200SP IM155-6 PN HF (All versions < V4.2.0), SIMATIC ET 200SP IM155-6 PN HA (All versions < V1.1.0), SIMATIC ET 200SP IM155-6 PN BA (All versions), SIMATIC ET 200SP IM155-6 PN ST (All versions), SIMATIC ET 200SP IM155-6 PN HS (All versions), Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions < V4.1.1 Patch 05), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P (All versions < V4.5), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All versions < V4.5), SIMOTION D (All versions < V5.1 HF1), SIMOTION C (All versions < V5.1 HF1), SIMOTION P V4.4 and V4.5 (All versions < V4.5 HF5), SIMOTION P V5 (All versions < V5.1 HF1), SINAMICS DCM w. PN (All versions < V1.2 HF2), SINAMICS G110M w. PN (All versions < V1.02), SINUMERIK 840D sl (All versions), SIMATIC Compact Field Unit (All versions), SIMATIC PN/PN Coupler (All versions < V4.2.0), SIMOCODE pro V PROFINET (All versions < V2.1.1), SIRIUS Soft Starter 3RW44 PN (All versions), SIMOCODE pro V EIP (All versions < V1.0.2). Siemens SIMATIC S7-1500 CPU, etc. SIMATIC S7-1500 CPU is a CPU (central processing unit) module. SIMATIC S7-1500 is a programmable logic controller. SINUMERIK 840D sl is a set of advanced machine tool numerical control system

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201712-0703",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "sinamics s120",
        "scope": "eq",
        "trust": 1.9,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics s150 v4.8",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sirius soft starter 3rw44pn",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics s110pn",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic compact field unit",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics s150 v4.7",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinumerik 840d sl",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics v90pn",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simocode pro v profinet",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic pn\\/pn coupler",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-300",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-1200",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-1500",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-1500 software controller",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200al",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200ecopn",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200m",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200mp",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200pro",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200s",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics dcm",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics dcp",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200sp",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "dk standard ethernet controller",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics s120",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinumerik 840d sl",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic compact field unit",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic pn/pn coupler",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sirius soft starter 3rw44 pn",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics g150",
        "scope": "eq",
        "trust": 1.3,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics g130",
        "scope": "eq",
        "trust": 1.3,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics dcm",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-1200",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-200",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.03.01"
      },
      {
        "model": "dk standard ethernet controller",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-400h v6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "6.0.8"
      },
      {
        "model": "simatic et 200sp",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200al",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics g110m\\/g120pn",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "simatic s7-1500",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.0"
      },
      {
        "model": "simatic s7-1500 controller",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.0"
      },
      {
        "model": "simatic et 200mp",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-400pn\\/dp v7",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-400pn v6",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "6.0.6"
      },
      {
        "model": "simatic winac rtx f 2010",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200ecopn",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200pro",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "ek-ertec 200pn io",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-300",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simotion p",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.1"
      },
      {
        "model": "simatic et 200m",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics dcp",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-410 v8",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "ek-ertec 200p",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "simatic et 200s",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simotion c",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.1"
      },
      {
        "model": "simotion d",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.1"
      },
      {
        "model": "ek-ertec 200 pn io",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "ek-ertec 200p p",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-200 smart",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-400 pn v6",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-400 pn/dp v7",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-400h v6",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-410 v8",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic winac rtx 2010 incl. f",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simocode pro v profinet",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simotion c",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simotion d",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simotion p",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics g110m",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics g130",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics g150",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics s110 w. pn",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics s150 v4.7 w. pn",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics s150 v4.8 w. pn",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics v90 w. pn",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-200 smart",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v2.03.01"
      },
      {
        "model": "simatic s7-400 pn",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v6\u003cv6.0.6"
      },
      {
        "model": "simatic s7-400 h",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v6"
      },
      {
        "model": "simatic s7-400 pn/dp",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v7"
      },
      {
        "model": "simatic s7-410",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v8"
      },
      {
        "model": "simatic winac rtx incl.f",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "2010"
      },
      {
        "model": "ek-ertec pn io",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "200"
      },
      {
        "model": "simotion d hf1",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v5.1"
      },
      {
        "model": "simotion c hf1",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v5.1"
      },
      {
        "model": "simotion p hf1",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v5.1"
      },
      {
        "model": "sinamics g110m/g120 w.pn sp9 hf1",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v4.7"
      },
      {
        "model": "ek-ertec 200p",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v4.5"
      },
      {
        "model": "sinamics s110 w.pn",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics s150",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v4.7"
      },
      {
        "model": "sinamics s150",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v4.8"
      },
      {
        "model": "sinamics w.pn",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v90"
      },
      {
        "model": "simocode pro profinet",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v"
      },
      {
        "model": "sinamics g130 and g150",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "softnet profinet io",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "sirius soft starter 3rw44 pn",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "sinumerik 840d sl",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinumerik 840d",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "sinamics sm150",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics sm120",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics sl150",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7.5"
      },
      {
        "model": "sinamics sl150",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7.4"
      },
      {
        "model": "sinamics sl150",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics s150",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics s120",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "sinamics gm150",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics gl150",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics gh150",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics g120",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics dcp",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "sinamics dcm",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simotion",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simocode pro eip",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v1.0.1"
      },
      {
        "model": "simocode pro eip",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v1.0"
      },
      {
        "model": "simatic winac rtx",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "20100"
      },
      {
        "model": "simatic winac rtx f sp2",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "2010"
      },
      {
        "model": "simatic winac rtx sp2",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "2010"
      },
      {
        "model": "simatic s7-410",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "8"
      },
      {
        "model": "simatic s7-400 pn",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v60"
      },
      {
        "model": "simatic s7-400 pn",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic s7-400 h",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v60"
      },
      {
        "model": "simatic s7-300",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic s7-200",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic s7-1500",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1.8.3"
      },
      {
        "model": "simatic s7-1500",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1.6"
      },
      {
        "model": "simatic s7-1500",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1.5.0"
      },
      {
        "model": "simatic s7-1500",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic s7-1200",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.1.3"
      },
      {
        "model": "simatic s7-1200",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.0"
      },
      {
        "model": "simatic s7-1200",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "3.0.1"
      },
      {
        "model": "simatic s7-1200",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "3.0.0"
      },
      {
        "model": "simatic s7-1200",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "3.0"
      },
      {
        "model": "simatic s7-1200",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "2.0.3"
      },
      {
        "model": "simatic s7-1200",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "2.0.2"
      },
      {
        "model": "simatic et",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "2000"
      },
      {
        "model": "simatic compact field unit",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "profinet io",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1.4.1"
      },
      {
        "model": "profinet io",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "sinamics sm120 sp2",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "sinamics sl150 sp2",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "sinamics gm150 sp2",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "sinamics gl150 sp2",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "sinamics gh150 sp2",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "sinamics g120p",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics g120d",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics g120c",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics g120 update sp9 hf1",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics g110m",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simotion p hf1",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "5.1"
      },
      {
        "model": "simotion c hf1",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "5.1"
      },
      {
        "model": "simocode pro eip",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v1.0.2"
      },
      {
        "model": "simatic s7-400 pn",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v66.0.6"
      },
      {
        "model": "simatic s7-200 smart",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "2.3.1"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 200",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic winac rtx f 2010",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200al",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200ecopn",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200m",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200mp",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200pro",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200s",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200sp",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dk standard ethernet controller",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "ek ertec 200p",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 400pn v6",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "ek ertec 200pn io",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simotion d",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simotion c",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simotion p",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics dcm",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics dcp",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics g110m g120pn",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics g130",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics g150",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics s110pn",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 400h v6",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics s120",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics s150 v4 7",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics s150 v4 8",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics v90pn",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinumerik 840d sl",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic compact field unit",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic pn pn coupler",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simocode pro v profinet",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sirius soft starter 3rw44pn",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 400pn dp v7",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 410 v8",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 300",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 1200",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 1500",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 1500 controller",
        "version": "2.0"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "e2df32de-39ab-11e9-b092-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-36884"
      },
      {
        "db": "BID",
        "id": "101964"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-011798"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-12741"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201711-1105"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-200_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "2.03.01",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-200:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-400pn_v6_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "6.0.6",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-400pn_v6:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-400h_v6_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "6.0.8",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-400h_v6:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-400pn\\/dp_v7_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-400pn\\/dp_v7:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-410_v8_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-410_v8:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1200_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1200:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1500_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "2.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1500:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1500_controller_firmware:2.0:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1500_controller:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_winac_rtx_f_2010_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_winac_rtx_f_2010:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200al_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200al:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200ecopn_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200ecopn:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200m_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200m:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200mp_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200mp:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200pro_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200pro:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200s_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200s:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200sp_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200sp:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:dk_standard_ethernet_controller:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:ek-ertec_200p_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:ek-ertec_200p:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:ek-ertec_200pn_io_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:ek-ertec_200pn_io:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simotion_d_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndIncluding": "5.1",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simotion_d:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simotion_c_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndIncluding": "5.1",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simotion_c:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simotion_p_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndIncluding": "5.1",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simotion_p:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_dcm_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_dcm:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_dcp_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_dcp:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g110m\\/g120pn_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndIncluding": "4.7",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_g110m\\/g120pn:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g130_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_g130:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g150_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_g150:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_s110pn_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_s110pn:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_s120_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_s150_v4.7_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_s150_v4.7:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_s150_v4.8_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_s150_v4.8:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_v90pn_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_v90pn:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinumerik_840d_sl_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinumerik_840d_sl:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_compact_field_unit_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_compact_field_unit:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_pn\\/pn_coupler_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_pn\\/pn_coupler:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simocode_pro_v_profinet_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simocode_pro_v_profinet:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sirius_soft_starter_3rw44pn_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sirius_soft_starter_3rw44pn:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2017-12741"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Siemens ProductCERT reported this vulnerability to NCCIC.",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201711-1105"
      }
    ],
    "trust": 0.6
  },
  "cve": "CVE-2017-12741",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "HIGH",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Complete",
            "baseScore": 7.8,
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2017-12741",
            "impactScore": null,
            "integrityImpact": "None",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2017-36884",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "e2df32de-39ab-11e9-b092-000c29342cb1",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.2,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "VHN-103294",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 7.5,
            "baseSeverity": "High",
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2017-12741",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2017-12741",
            "trust": 1.8,
            "value": "HIGH"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2017-36884",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201711-1105",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "IVD",
            "id": "e2df32de-39ab-11e9-b092-000c29342cb1",
            "trust": 0.2,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-103294",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "e2df32de-39ab-11e9-b092-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-36884"
      },
      {
        "db": "VULHUB",
        "id": "VHN-103294"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-011798"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-12741"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201711-1105"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, SIMATIC Compact Field Unit, SIMATIC ET200AL, SIMATIC ET200M (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN BA (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN HF (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN ST (incl. SIPLUS variants), SIMATIC ET200S (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN BA (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HA (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HS (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN ST (incl. SIPLUS variants), SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 4AO U/I 4xM12, SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12, SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12, SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN: IO-Link Master, SIMATIC ET200pro, SIMATIC PN/PN Coupler (incl. SIPLUS NET variants), SIMATIC S7-1200 CPU family (incl. SIPLUS variants), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-1500 Software Controller, SIMATIC S7-200 SMART, SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-400 H V6 CPU family and below (incl. SIPLUS variants), SIMATIC S7-400 PN/DP V6 CPU family and below (incl. SIPLUS variants), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants), SIMATIC TDC CP51M1, SIMATIC TDC CPU555, SIMATIC WinAC RTX (F) 2010, SIMOCODE pro V EIP (incl. SIPLUS variants), SIMOCODE pro V PN (incl. SIPLUS variants), SIMOTION C, SIMOTION D (incl. SIPLUS variants), SIMOTION D4xx V4.4 for SINAMICS SM150i-2 w. PROFINET (incl. SIPLUS variants), SIMOTION P V4.4 and V4.5, SIMOTION P V5, SINAMICS DCM w. PN, SINAMICS DCP w. PN, SINAMICS G110M w. PN, SINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants), SINAMICS G130 V4.7 w. PN, SINAMICS G130 V4.8 w. PN, SINAMICS G150 V4.7 w. PN, SINAMICS G150 V4.8 w. PN, SINAMICS GH150 V4.7 w. PROFINET, SINAMICS GL150 V4.7 w. PROFINET, SINAMICS GM150 V4.7 w. PROFINET, SINAMICS S110 w. PN, SINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants), SINAMICS S120 V4.7 w. PN (incl. SIPLUS variants), SINAMICS S120 V4.8 w. PN (incl. SIPLUS variants), SINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants), SINAMICS S150 V4.7 w. PN, SINAMICS S150 V4.8 w. PN, SINAMICS SL150 V4.7.0 w. PROFINET, SINAMICS SL150 V4.7.4 w. PROFINET, SINAMICS SL150 V4.7.5 w. PROFINET, SINAMICS SM120 V4.7 w. PROFINET, SINAMICS V90 w. PN, SINUMERIK 840D sl, SIRIUS Soft Starter 3RW44 PN. Specially crafted packets sent to port 161/udp could cause a Denial-of-Service condition. The affected devices must be restarted manually. plural Siemens The product contains data processing vulnerabilities.Service operation interruption (DoS) There is a possibility of being put into a state. SiemensSIMATICS7-200Smart and others are products of Siemens AG. The Siemens SIMATICS7-200Smart is a programmable logic controller (PLC) for use in small and medium-sized automation systems. SIMATICWinACRTX2010incl is a software controller for automation solutions. A denial of service vulnerability exists in several Siemens products. \nAttackers can exploit this issue to crash the affected device, denying service to legitimate users. A vulnerability has been identified in SIMATIC S7-200 Smart (All versions \u003c V2.03.01), SIMATIC S7-400 PN V6 (All versions \u003c V6.0.6), SIMATIC S7-400 H V6 (All versions \u003c V6.0.8), SIMATIC S7-400 PN/DP V7 (All versions \u003c V7.0.2), SIMATIC S7-410 V8 (All versions \u003c V8.2.1), SIMATIC S7-300 (All versions \u003c V3.X.16), SIMATIC S7-1200 (All versions \u003c V4.2.3), SIMATIC S7-1500 (All versions \u003c V2.0), SIMATIC S7-1500 Software Controller (All versions \u003c V2.0), SIMATIC WinAC RTX 2010 incl. F (All versions), SIMATIC ET 200AL (All versions), SIMATIC ET 200ecoPN (All versions), SIMATIC ET 200M (All versions), SIMATIC ET 200MP IM155-5 PN BA (All versions \u003c V4.0.2), SIMATIC ET 200MP IM155-5 PN ST (All versions \u003c V4.1), SIMATIC ET 200MP IM155-5 PN HF (All versions \u003c V4.2), SIMATIC ET 200pro (All versions), SIMATIC ET 200S (All versions), SIMATIC ET 200SP IM155-6 PN HF (All versions \u003c V4.2.0), SIMATIC ET 200SP IM155-6 PN HA (All versions \u003c V1.1.0), SIMATIC ET 200SP IM155-6 PN BA (All versions), SIMATIC ET 200SP IM155-6 PN ST (All versions), SIMATIC ET 200SP IM155-6 PN HS (All versions), Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions \u003c V4.1.1 Patch 05), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P (All versions \u003c V4.5), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All versions \u003c V4.5), SIMOTION D (All versions \u003c V5.1 HF1), SIMOTION C (All versions \u003c V5.1 HF1), SIMOTION P V4.4 and V4.5 (All versions \u003c V4.5 HF5), SIMOTION P V5 (All versions \u003c V5.1 HF1), SINAMICS DCM w. PN (All versions \u003c V1.2 HF2), SINAMICS G110M w. PN (All versions \u003c V1.02), SINUMERIK 840D sl (All versions), SIMATIC Compact Field Unit (All versions), SIMATIC PN/PN Coupler (All versions \u003c V4.2.0), SIMOCODE pro V PROFINET (All versions \u003c V2.1.1), SIRIUS Soft Starter 3RW44 PN (All versions), SIMOCODE pro V EIP (All versions \u003c V1.0.2). Siemens SIMATIC S7-1500 CPU, etc. SIMATIC S7-1500 CPU is a CPU (central processing unit) module. SIMATIC S7-1500 is a programmable logic controller. SINUMERIK 840D sl is a set of advanced machine tool numerical control system",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2017-12741"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-011798"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-36884"
      },
      {
        "db": "BID",
        "id": "101964"
      },
      {
        "db": "IVD",
        "id": "e2df32de-39ab-11e9-b092-000c29342cb1"
      },
      {
        "db": "VULHUB",
        "id": "VHN-103294"
      }
    ],
    "trust": 2.7
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2017-12741",
        "trust": 3.6
      },
      {
        "db": "BID",
        "id": "101964",
        "trust": 2.6
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-17-339-01",
        "trust": 2.3
      },
      {
        "db": "SIEMENS",
        "id": "SSA-346262",
        "trust": 2.0
      },
      {
        "db": "SIEMENS",
        "id": "SSA-546832",
        "trust": 2.0
      },
      {
        "db": "SIEMENS",
        "id": "SSA-141614",
        "trust": 1.7
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-18-128-01",
        "trust": 1.7
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-19-099-01",
        "trust": 1.7
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201711-1105",
        "trust": 0.9
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-36884",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-011798",
        "trust": 0.8
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2019.1206",
        "trust": 0.6
      },
      {
        "db": "IVD",
        "id": "E2DF32DE-39AB-11E9-B092-000C29342CB1",
        "trust": 0.2
      },
      {
        "db": "VULHUB",
        "id": "VHN-103294",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "e2df32de-39ab-11e9-b092-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-36884"
      },
      {
        "db": "VULHUB",
        "id": "VHN-103294"
      },
      {
        "db": "BID",
        "id": "101964"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-011798"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-12741"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201711-1105"
      }
    ]
  },
  "id": "VAR-201712-0703",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "e2df32de-39ab-11e9-b092-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-36884"
      },
      {
        "db": "VULHUB",
        "id": "VHN-103294"
      }
    ],
    "trust": 1.5574432950000001
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS",
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      },
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.2
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "e2df32de-39ab-11e9-b092-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-36884"
      }
    ]
  },
  "last_update_date": "2023-12-18T12:51:14.227000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-346262",
        "trust": 0.8,
        "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-346262.pdf"
      },
      {
        "title": "Patches for multiple Siemens product denial of service vulnerabilities",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchinfo/show/109849"
      },
      {
        "title": "Multiple Siemens Product security vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=76771"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-36884"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-011798"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201711-1105"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-400",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-19",
        "trust": 0.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-103294"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-011798"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-12741"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.9,
        "url": "https://www.securityfocus.com/bid/101964"
      },
      {
        "trust": 2.3,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-17-339-01"
      },
      {
        "trust": 1.7,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-141614.pdf"
      },
      {
        "trust": 1.7,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-346262.pdf"
      },
      {
        "trust": 1.7,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf"
      },
      {
        "trust": 1.7,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-18-128-01"
      },
      {
        "trust": 0.9,
        "url": "http://www.siemens.com/"
      },
      {
        "trust": 0.9,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-19-099-01"
      },
      {
        "trust": 0.9,
        "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-346262.pdf"
      },
      {
        "trust": 0.9,
        "url": "https://cert-portal.siemens.com/productcert/txt/ssa-546832.txt"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-12741"
      },
      {
        "trust": 0.8,
        "url": "https://www.us-cert.gov/ics/advisories/icsa-19-099-01"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2017-12741"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/78750"
      },
      {
        "trust": 0.6,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-17-339-01"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-36884"
      },
      {
        "db": "VULHUB",
        "id": "VHN-103294"
      },
      {
        "db": "BID",
        "id": "101964"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-011798"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-12741"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201711-1105"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "e2df32de-39ab-11e9-b092-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-36884"
      },
      {
        "db": "VULHUB",
        "id": "VHN-103294"
      },
      {
        "db": "BID",
        "id": "101964"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-011798"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-12741"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201711-1105"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2017-12-12T00:00:00",
        "db": "IVD",
        "id": "e2df32de-39ab-11e9-b092-000c29342cb1"
      },
      {
        "date": "2017-12-12T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2017-36884"
      },
      {
        "date": "2017-12-26T00:00:00",
        "db": "VULHUB",
        "id": "VHN-103294"
      },
      {
        "date": "2017-11-23T00:00:00",
        "db": "BID",
        "id": "101964"
      },
      {
        "date": "2018-01-26T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2017-011798"
      },
      {
        "date": "2017-12-26T04:29:13.707000",
        "db": "NVD",
        "id": "CVE-2017-12741"
      },
      {
        "date": "2017-11-28T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201711-1105"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2017-12-12T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2017-36884"
      },
      {
        "date": "2020-08-14T00:00:00",
        "db": "VULHUB",
        "id": "VHN-103294"
      },
      {
        "date": "2019-04-10T07:00:00",
        "db": "BID",
        "id": "101964"
      },
      {
        "date": "2019-07-08T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2017-011798"
      },
      {
        "date": "2022-02-09T16:15:08.687000",
        "db": "NVD",
        "id": "CVE-2017-12741"
      },
      {
        "date": "2022-02-11T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201711-1105"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201711-1105"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Siemens Data processing vulnerabilities in products",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-011798"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "resource management error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201711-1105"
      }
    ],
    "trust": 0.6
  }
}

cve-2017-2680
Vulnerability from cvelistv5
Published
2017-05-11 01:00
Modified
2024-09-10 09:33
Summary
Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected.
Impacted products
VendorProduct
SiemensDevelopment/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller
SiemensDevelopment/Evaluation Kits for PROFINET IO: EK-ERTEC 200
SiemensDevelopment/Evaluation Kits for PROFINET IO: EK-ERTEC 200P
SiemensExtension Unit 12" PROFINET
SiemensExtension Unit 15" PROFINET
SiemensExtension Unit 19" PROFINET
SiemensExtension Unit 22" PROFINET
SiemensIE/AS-i Link PN IO
SiemensIE/PB-Link (incl. SIPLUS NET variants)
SiemensSCALANCE M-800 family (incl. S615, MUM-800 and RM1224)
SiemensSCALANCE W-700 IEEE 802.11n family
SiemensSCALANCE X-200 family (incl. SIPLUS NET variants)
SiemensSCALANCE X-200IRT family (incl. SIPLUS NET variants)
SiemensSCALANCE X-300 family (incl. X408 and SIPLUS NET variants)
SiemensSCALANCE X408 family
SiemensSCALANCE X414
SiemensSCALANCE XM-400 family
SiemensSCALANCE XR-500 family
SiemensSIMATIC CM 1542-1
SiemensSIMATIC CM 1542SP-1
SiemensSIMATIC CP 1242-7 V2 (incl. SIPLUS variants)
SiemensSIMATIC CP 1243-1 (incl. SIPLUS variants)
SiemensSIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)
SiemensSIMATIC CP 1243-1 IEC (incl. SIPLUS variants)
SiemensSIMATIC CP 1243-7 LTE US
SiemensSIMATIC CP 1243-8 IRC
SiemensSIMATIC CP 1243-8 IRC
SiemensSIMATIC CP 1542SP-1 IRC (incl. SIPLUS variants)
SiemensSIMATIC CP 1543-1 (incl. SIPLUS variants)
SiemensSIMATIC CP 1543SP-1 (incl. SIPLUS variants)
SiemensSIMATIC CP 1604
SiemensSIMATIC CP 1616
SiemensSIMATIC CP 1626
SiemensSIMATIC CP 343-1 (incl. SIPLUS variants)
SiemensSIMATIC CP 343-1 Advanced (incl. SIPLUS variants)
SiemensSIMATIC CP 343-1 Lean (incl. SIPLUS variants)
SiemensSIMATIC CP 443-1 (incl. SIPLUS variants)
SiemensSIMATIC CP 443-1 Advanced (incl. SIPLUS variants)
SiemensSIMATIC CP 443-1 OPC UA
SiemensSIMATIC DK-16xx PN IO
SiemensSIMATIC ET 200AL IM 157-1 PN
SiemensSIMATIC ET 200M (incl. SIPLUS variants)
SiemensSIMATIC ET 200MP IM 155-5 PN BA
SiemensSIMATIC ET 200MP IM 155-5 PN HF
SiemensSIMATIC ET 200MP IM 155-5 PN ST
SiemensSIMATIC ET 200pro IM 154-3 PN HF
SiemensSIMATIC ET 200pro IM 154-4 PN HF
SiemensSIMATIC ET 200SP IM 155-6 PN BA
SiemensSIMATIC ET 200SP IM 155-6 PN HF
SiemensSIMATIC ET 200SP IM 155-6 PN HS
SiemensSIMATIC ET 200SP IM 155-6 PN ST
SiemensSIMATIC ET 200SP IM 155-6 PN ST BA
SiemensSIMATIC ET200ecoPN, 16DI, DC24V, 8xM12
SiemensSIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12
SiemensSIMATIC ET200ecoPN, 4AO U/I 4xM12
SiemensSIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12
SiemensSIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12
SiemensSIMATIC ET200ecoPN, 8AI RTD/TC 8xM12
SiemensSIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12
SiemensSIMATIC ET200ecoPN, 8DI, DC24V, 4xM12
SiemensSIMATIC ET200ecoPN, 8DI, DC24V, 8xM12
SiemensSIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12
SiemensSIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12
SiemensSIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12
SiemensSIMATIC ET200ecoPN: IO-Link Master
SiemensSIMATIC ET200S (incl. SIPLUS variants)
SiemensSIMATIC HMI Comfort Panels, HMI Multi Panels, HMI Mobile Panels (incl. SIPLUS variants)
SiemensSIMATIC MV420 SR-B
SiemensSIMATIC MV420 SR-B Body
SiemensSIMATIC MV420 SR-P
SiemensSIMATIC MV420 SR-P Body
SiemensSIMATIC MV440 HR
SiemensSIMATIC MV440 SR
SiemensSIMATIC MV440 UR
SiemensSIMATIC PN/PN Coupler (incl. SIPLUS NET variants)
SiemensSIMATIC RF650R
SiemensSIMATIC RF680R
SiemensSIMATIC RF685R
SiemensSIMATIC S7-1200 CPU family (incl. SIPLUS variants)
SiemensSIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)
SiemensSIMATIC S7-1500 Software Controller
SiemensSIMATIC S7-200 SMART
SiemensSIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)
SiemensSIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)
SiemensSIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants)
SiemensSIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)
SiemensSIMATIC S7-410 CPU family (incl. SIPLUS variants)
SiemensSIMATIC TDC CP51M1
SiemensSIMATIC TDC CPU555
SiemensSIMATIC Teleservice Adapter IE Advanced
SiemensSIMATIC Teleservice Adapter IE Basic
SiemensSIMATIC Teleservice Adapter IE Standard
SiemensSIMATIC WinAC RTX 2010
SiemensSIMATIC WinAC RTX F 2010
SiemensSIMOCODE pro V PROFINET (incl. SIPLUS variants)
SiemensSIMOTION
SiemensSIMOTION D4xx V4.4 for SINAMICS SM150i-2 w. PROFINET (incl. SIPLUS variants)
SiemensSINAMICS DCM w. PN
SiemensSINAMICS DCP w. PN
SiemensSINAMICS G110M w. PN
SiemensSINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants)
SiemensSINAMICS G130 V4.7 w. PN
SiemensSINAMICS G130 V4.8 w. PN
SiemensSINAMICS G150 V4.7 w. PN
SiemensSINAMICS G150 V4.8 w. PN
SiemensSINAMICS GH150 V4.7 w. PROFINET
SiemensSINAMICS GL150 V4.7 w. PROFINET
SiemensSINAMICS GM150 V4.7 w. PROFINET
SiemensSINAMICS S110 w. PN
SiemensSINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants)
SiemensSINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants)
SiemensSINAMICS S120 V4.7 w. PN (incl. SIPLUS variants)
SiemensSINAMICS S120 V4.8 w. PN (incl. SIPLUS variants)
SiemensSINAMICS S150 V4.7 w. PN
SiemensSINAMICS S150 V4.8 w. PN
SiemensSINAMICS SL150 V4.7.0 w. PROFINET
SiemensSINAMICS SL150 V4.7.4 w. PROFINET
SiemensSINAMICS SL150 V4.7.5 w. PROFINET
SiemensSINAMICS SM120 V4.7 w. PROFINET
SiemensSINAMICS V90 w. PN
SiemensSINUMERIK 828D V4.5 and prior
SiemensSINUMERIK 828D V4.7
SiemensSINUMERIK 840D sl V4.5 and prior
SiemensSINUMERIK 840D sl V4.7
SiemensSIPLUS ET 200MP IM 155-5 PN HF
SiemensSIPLUS ET 200MP IM 155-5 PN HF
SiemensSIPLUS ET 200MP IM 155-5 PN HF T1 RAIL
SiemensSIPLUS ET 200MP IM 155-5 PN ST
SiemensSIPLUS ET 200MP IM 155-5 PN ST TX RAIL
SiemensSIPLUS ET 200SP IM 155-6 PN HF
SiemensSIPLUS ET 200SP IM 155-6 PN HF
SiemensSIPLUS ET 200SP IM 155-6 PN HF T1 RAIL
SiemensSIPLUS ET 200SP IM 155-6 PN ST
SiemensSIPLUS ET 200SP IM 155-6 PN ST BA
SiemensSIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL
SiemensSIPLUS ET 200SP IM 155-6 PN ST TX RAIL
SiemensSIRIUS ACT 3SU1 interface module PROFINET
SiemensSIRIUS Motor Starter M200D PROFINET
SiemensSIRIUS Soft Starter 3RW44 PN
SiemensSITOP PSU8600 PROFINET
SiemensSITOP UPS1600 PROFINET (incl. SIPLUS variants)
SiemensSoftnet PROFINET IO for PC-based Windows systems
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2017-2680",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-09T13:26:04.237652Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-09T13:26:15.327Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T14:02:07.270Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "1038463",
            "tags": [
              "vdb-entry",
              "x_refsource_SECTRACK",
              "x_transferred"
            ],
            "url": "http://www.securitytracker.com/id/1038463"
          },
          {
            "name": "98369",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/98369"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-023-02"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-284673.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-284673.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-546832.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.1 Patch04"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.2.1 Patch03"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4.0 Patch01"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Extension Unit 12\" PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V01.01.01"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Extension Unit 15\" PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V01.01.01"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Extension Unit 19\" PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V01.01.01"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Extension Unit 22\" PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V01.01.01"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IE/AS-i Link PN IO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IE/PB-Link (incl. SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M-800 family (incl. S615, MUM-800 and RM1224)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.03"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W-700 IEEE 802.11n family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X-200 family (incl. SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X-200IRT family (incl. SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.4.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X-300 family (incl. X408 and SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X408 family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X414",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.10.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM-400 family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR-500 family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CM 1542-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CM 1542SP-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.0.15"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1242-7 V2 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1.82"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1.82"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-7 LTE US",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1.82"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-8 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1.82"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-8 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1.82"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1542SP-1 IRC (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.0.15"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1543-1 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1543SP-1 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.0.15"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1604",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1616",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1626",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 343-1 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.1.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 343-1 Advanced (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 343-1 Lean (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.1.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1 Advanced (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1 OPC UA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC DK-16xx PN IO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200AL IM 157-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V1.0.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200M (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200MP IM 155-5 PN BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.0.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200MP IM 155-5 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200MP IM 155-5 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM 154-3 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM 154-4 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN HS",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.0.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN ST BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 4AO U/I 4xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN: IO-Link Master",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200S (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC HMI Comfort Panels, HMI Multi Panels, HMI Mobile Panels (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV420 SR-B",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV420 SR-B Body",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV420 SR-P",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV420 SR-P Body",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV440 HR",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV440 SR",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV440 UR",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PN/PN Coupler (incl. SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC RF650R",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC RF680R",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC RF685R",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 Software Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-200 SMART",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.X.14",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0.7",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-410 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC TDC CP51M1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V1.1.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC TDC CPU555",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V1.1.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Teleservice Adapter IE Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Teleservice Adapter IE Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Teleservice Adapter IE Standard",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinAC RTX 2010",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2010 SP3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinAC RTX F 2010",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2010 SP3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOCODE pro V PROFINET (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTION",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.5 HF1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTION D4xx V4.4 for SINAMICS SM150i-2 w. PROFINET (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4 HF26"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS DCM w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.4 SP1 HF5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS DCP w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.2 HF1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G110M w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 SP6 HF3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 SP6 HF3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G130 V4.7 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 HF27"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G130 V4.8 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 HF4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G150 V4.7 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "V4.7: All versions \u003c V4.7 HF27"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G150 V4.8 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 HF4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS GH150 V4.7 w. PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 SP5 HF7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS GL150 V4.7 w. PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 SP2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS GM150 V4.7 w. PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 HF31"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S110 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4 SP3 HF5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 V4.7 w. PN (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 HF27"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 V4.8 w. PN (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 HF4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S150 V4.7 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 HF27"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S150 V4.8 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 HF4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS SL150 V4.7.0 w. PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 HF30"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS SL150 V4.7.4 w. PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 SP2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS SL150 V4.7.5 w. PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 SP2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS SM120 V4.7 w. PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 SP2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS V90 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.01"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINUMERIK 828D V4.5 and prior",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.5 SP6 HF2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINUMERIK 828D V4.7",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 SP4 HF1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINUMERIK 840D sl V4.5 and prior",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.5 SP6 HF2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINUMERIK 840D sl V4.7",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 SP4 HF1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN ST TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIRIUS ACT 3SU1 interface module PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.1.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIRIUS Motor Starter M200D PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIRIUS Soft Starter 3RW44 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SITOP PSU8600 PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SITOP UPS1600 PROFINET (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Softnet PROFINET IO for PC-based Windows systems",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14 SP1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-400",
              "description": "CWE-400: Uncontrolled Resource Consumption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-10T09:33:18.492Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "name": "1038463",
          "tags": [
            "vdb-entry",
            "x_refsource_SECTRACK"
          ],
          "url": "http://www.securitytracker.com/id/1038463"
        },
        {
          "name": "98369",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/98369"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-023-02"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-284673.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-284673.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-546832.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2017-2680",
    "datePublished": "2017-05-11T01:00:00",
    "dateReserved": "2016-12-01T00:00:00",
    "dateUpdated": "2024-09-10T09:33:18.492Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2017-12741
Vulnerability from cvelistv5
Published
2017-12-26 04:00
Modified
2024-08-05 18:51
Summary
Specially crafted packets sent to port 161/udp could cause a denial of service condition. The affected devices must be restarted manually.
Impacted products
VendorProduct
SiemensDevelopment/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller
SiemensDevelopment/Evaluation Kits for PROFINET IO: EK-ERTEC 200
SiemensDevelopment/Evaluation Kits for PROFINET IO: EK-ERTEC 200P
SiemensSIMATIC Compact Field Unit
SiemensSIMATIC ET 200AL IM 157-1 PN
SiemensSIMATIC ET 200M (incl. SIPLUS variants)
SiemensSIMATIC ET 200MP IM 155-5 PN BA
SiemensSIMATIC ET 200MP IM 155-5 PN HF
SiemensSIMATIC ET 200MP IM 155-5 PN ST
SiemensSIMATIC ET 200pro IM 154-3 PN HF
SiemensSIMATIC ET 200pro IM 154-4 PN HF
SiemensSIMATIC ET 200SP IM 155-6 PN BA
SiemensSIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants)
SiemensSIMATIC ET 200SP IM 155-6 PN HF
SiemensSIMATIC ET 200SP IM 155-6 PN HS
SiemensSIMATIC ET 200SP IM 155-6 PN ST
SiemensSIMATIC ET 200SP IM 155-6 PN ST
SiemensSIMATIC ET 200SP IM 155-6 PN ST BA
SiemensSIMATIC ET 200SP IM 155-6 PN ST BA
SiemensSIMATIC ET200ecoPN, 16DI, DC24V, 8xM12
SiemensSIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12
SiemensSIMATIC ET200ecoPN, 4AO U/I 4xM12
SiemensSIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12
SiemensSIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12
SiemensSIMATIC ET200ecoPN, 8AI RTD/TC 8xM12
SiemensSIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12
SiemensSIMATIC ET200ecoPN, 8DI, DC24V, 4xM12
SiemensSIMATIC ET200ecoPN, 8DI, DC24V, 8xM12
SiemensSIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12
SiemensSIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12
SiemensSIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12
SiemensSIMATIC ET200ecoPN: IO-Link Master
SiemensSIMATIC ET200S (incl. SIPLUS variants)
SiemensSIMATIC PN/PN Coupler (incl. SIPLUS NET variants)
SiemensSIMATIC S7-1200 CPU family (incl. SIPLUS variants)
SiemensSIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)
SiemensSIMATIC S7-1500 Software Controller
SiemensSIMATIC S7-200 SMART
SiemensSIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)
SiemensSIMATIC S7-400 H V6 and below CPU family (incl. SIPLUS variants)
SiemensSIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)
SiemensSIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)
SiemensSIMATIC S7-410 V8 CPU family (incl. SIPLUS variants)
SiemensSIMATIC TDC CP51M1
SiemensSIMATIC TDC CPU555
SiemensSIMATIC WinAC RTX 2010
SiemensSIMATIC WinAC RTX F 2010
SiemensSIMOCODE pro V PROFINET (incl. SIPLUS variants)
SiemensSIMOTION C
SiemensSIMOTION D
SiemensSIMOTION D4xx V4.4 for SINAMICS SM150i-2 w. PROFINET (incl. SIPLUS variants)
SiemensSIMOTION P V4.4 and V4.5
SiemensSIMOTION P V5
SiemensSINAMICS DCM w. PN
SiemensSINAMICS DCP w. PN
SiemensSINAMICS G110M w. PN
SiemensSINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants)
SiemensSINAMICS G130 V4.7 w. PN
SiemensSINAMICS G130 V4.8 w. PN
SiemensSINAMICS G150 V4.7 w. PN
SiemensSINAMICS G150 V4.8 w. PN
SiemensSINAMICS GH150 V4.7 w. PROFINET
SiemensSINAMICS GL150 V4.7 w. PROFINET
SiemensSINAMICS GM150 V4.7 w. PROFINET
SiemensSINAMICS S110 w. PN
SiemensSINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants)
SiemensSINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants)
SiemensSINAMICS S120 V4.7 w. PN (incl. SIPLUS variants)
SiemensSINAMICS S120 V4.8 w. PN (incl. SIPLUS variants)
SiemensSINAMICS S150 V4.7 w. PN
SiemensSINAMICS S150 V4.8 w. PN
SiemensSINAMICS SL150 V4.7.0 w. PROFINET
SiemensSINAMICS SL150 V4.7.4 w. PROFINET
SiemensSINAMICS SL150 V4.7.5 w. PROFINET
SiemensSINAMICS SM120 V4.7 w. PROFINET
SiemensSINAMICS V90 w. PN
SiemensSINUMERIK 840D sl
SiemensSIPLUS ET 200MP IM 155-5 PN HF
SiemensSIPLUS ET 200MP IM 155-5 PN HF
SiemensSIPLUS ET 200MP IM 155-5 PN HF T1 RAIL
SiemensSIPLUS ET 200MP IM 155-5 PN ST
SiemensSIPLUS ET 200MP IM 155-5 PN ST TX RAIL
SiemensSIPLUS ET 200SP IM 155-6 PN HF
SiemensSIPLUS ET 200SP IM 155-6 PN HF
SiemensSIPLUS ET 200SP IM 155-6 PN HF T1 RAIL
SiemensSIPLUS ET 200SP IM 155-6 PN ST
SiemensSIPLUS ET 200SP IM 155-6 PN ST
SiemensSIPLUS ET 200SP IM 155-6 PN ST BA
SiemensSIPLUS ET 200SP IM 155-6 PN ST BA
SiemensSIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL
SiemensSIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL
SiemensSIPLUS ET 200SP IM 155-6 PN ST TX RAIL
SiemensSIPLUS ET 200SP IM 155-6 PN ST TX RAIL
SiemensSIRIUS Soft Starter 3RW44 PN
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T18:51:06.315Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "101964",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "https://www.securityfocus.com/bid/101964"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-346262.pdf"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-141614.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-346262.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-546832.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-141614.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.1 Patch 05"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Compact Field Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200AL IM 157-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V1.0.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200M (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200MP IM 155-5 PN BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.0.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200MP IM 155-5 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200MP IM 155-5 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM 154-3 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM 154-4 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.1.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN HS",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.0.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN ST BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN ST BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 4AO U/I 4xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN: IO-Link Master",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200S (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PN/PN Coupler (incl. SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.2.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 Software Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-200 SMART",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.03.01"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.X.16",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 H V6\u00a0and below\u00a0CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC TDC CP51M1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V1.1.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC TDC CPU555",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V1.1.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinAC RTX 2010",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2010 SP3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinAC RTX F 2010",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2010 SP3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOCODE pro V PROFINET (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTION C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.1 HF1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTION D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.1 HF1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTION D4xx V4.4 for SINAMICS SM150i-2 w. PROFINET (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4 HF26"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTION P V4.4 and V4.5",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.5 HF5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTION P V5",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.1 HF1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS DCM w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.4 SP1 HF6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS DCP w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.2 HF2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G110M w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 SP9 HF1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 SP9 HF1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G130 V4.7 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 HF29"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G130 V4.8 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 HF4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G150 V4.7 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 HF29"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G150 V4.8 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 HF4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS GH150 V4.7 w. PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 SP5 HF7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS GL150 V4.7 w. PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 SP2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS GM150 V4.7 w. PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 HF31"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S110 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4 SP3 HF6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 V4.7 w. PN (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 HF29"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 V4.8 w. PN (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 HF5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S150 V4.7 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 HF29"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S150 V4.8 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 HF4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS SL150 V4.7.0 w. PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 HF30"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS SL150 V4.7.4 w. PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 SP2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS SL150 V4.7.5 w. PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 SP2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS SM120 V4.7 w. PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 SP2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS V90 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.02"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINUMERIK 840D sl",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 SP3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN ST TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIRIUS Soft Starter 3RW44 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Specially crafted packets sent to port 161/udp could cause a denial of service condition. The affected devices must be restarted manually."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-400",
              "description": "CWE-400: Uncontrolled Resource Consumption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-09T12:03:53.948Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "name": "101964",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "https://www.securityfocus.com/bid/101964"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-346262.pdf"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-141614.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-346262.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-546832.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-141614.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2017-12741",
    "datePublished": "2017-12-26T04:00:00",
    "dateReserved": "2017-08-09T00:00:00",
    "dateUpdated": "2024-08-05T18:51:06.315Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2017-2681
Vulnerability from cvelistv5
Published
2017-05-11 10:00
Modified
2024-09-10 09:33
Summary
Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected.
Impacted products
VendorProduct
SiemensDevelopment/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller
SiemensDevelopment/Evaluation Kits for PROFINET IO: EK-ERTEC 200
SiemensDevelopment/Evaluation Kits for PROFINET IO: EK-ERTEC 200P
SiemensIE/AS-i Link PN IO
SiemensIE/PB-Link (incl. SIPLUS NET variants)
SiemensSCALANCE M-800 family (incl. S615, MUM-800 and RM1224)
SiemensSCALANCE W-700 IEEE 802.11n family
SiemensSCALANCE X-200 family (incl. SIPLUS NET variants)
SiemensSCALANCE X-200IRT family (incl. SIPLUS NET variants)
SiemensSCALANCE X-300 family (incl. X408 and SIPLUS NET variants)
SiemensSCALANCE X408 family
SiemensSCALANCE X414
SiemensSCALANCE XM-400 family
SiemensSCALANCE XR-500 family
SiemensSIMATIC CM 1542-1
SiemensSIMATIC CM 1542SP-1
SiemensSIMATIC CP 1243-1 (incl. SIPLUS variants)
SiemensSIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)
SiemensSIMATIC CP 1243-1 IEC (incl. SIPLUS variants)
SiemensSIMATIC CP 1243-8 IRC
SiemensSIMATIC CP 1542SP-1 IRC (incl. SIPLUS variants)
SiemensSIMATIC CP 1543-1 (incl. SIPLUS variants)
SiemensSIMATIC CP 1543SP-1 (incl. SIPLUS variants)
SiemensSIMATIC CP 1604
SiemensSIMATIC CP 1616
SiemensSIMATIC CP 343-1 (incl. SIPLUS variants)
SiemensSIMATIC CP 343-1 Advanced (incl. SIPLUS variants)
SiemensSIMATIC CP 343-1 Lean (incl. SIPLUS variants)
SiemensSIMATIC CP 443-1 (incl. SIPLUS variants)
SiemensSIMATIC CP 443-1 Advanced (incl. SIPLUS variants)
SiemensSIMATIC CP 443-1 OPC UA
SiemensSIMATIC DK-16xx PN IO
SiemensSIMATIC ET 200AL IM 157-1 PN
SiemensSIMATIC ET 200M (incl. SIPLUS variants)
SiemensSIMATIC ET 200MP IM 155-5 PN BA
SiemensSIMATIC ET 200MP IM 155-5 PN HF
SiemensSIMATIC ET 200MP IM 155-5 PN ST
SiemensSIMATIC ET 200pro IM 154-3 PN HF
SiemensSIMATIC ET 200pro IM 154-4 PN HF
SiemensSIMATIC ET 200SP IM 155-6 PN BA
SiemensSIMATIC ET 200SP IM 155-6 PN HF
SiemensSIMATIC ET 200SP IM 155-6 PN HS
SiemensSIMATIC ET 200SP IM 155-6 PN ST
SiemensSIMATIC ET 200SP IM 155-6 PN ST BA
SiemensSIMATIC ET200ecoPN, 16DI, DC24V, 8xM12
SiemensSIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12
SiemensSIMATIC ET200ecoPN, 4AO U/I 4xM12
SiemensSIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12
SiemensSIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12
SiemensSIMATIC ET200ecoPN, 8AI RTD/TC 8xM12
SiemensSIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12
SiemensSIMATIC ET200ecoPN, 8DI, DC24V, 4xM12
SiemensSIMATIC ET200ecoPN, 8DI, DC24V, 8xM12
SiemensSIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12
SiemensSIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12
SiemensSIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12
SiemensSIMATIC ET200ecoPN: IO-Link Master
SiemensSIMATIC ET200S (incl. SIPLUS variants)
SiemensSIMATIC HMI Comfort Panels, HMI Multi Panels, HMI Mobile Panels (incl. SIPLUS variants)
SiemensSIMATIC MV420 SR-B
SiemensSIMATIC MV420 SR-B Body
SiemensSIMATIC MV420 SR-P
SiemensSIMATIC MV420 SR-P Body
SiemensSIMATIC MV440 HR
SiemensSIMATIC MV440 SR
SiemensSIMATIC MV440 UR
SiemensSIMATIC PN/PN Coupler (incl. SIPLUS NET variants)
SiemensSIMATIC RF650R
SiemensSIMATIC RF680R
SiemensSIMATIC RF685R
SiemensSIMATIC S7-1200 CPU family (incl. SIPLUS variants)
SiemensSIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)
SiemensSIMATIC S7-1500 Software Controller
SiemensSIMATIC S7-200 SMART
SiemensSIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)
SiemensSIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)
SiemensSIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants)
SiemensSIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)
SiemensSIMATIC S7-410 CPU family (incl. SIPLUS variants)
SiemensSIMATIC TDC CP51M1
SiemensSIMATIC TDC CPU555
SiemensSIMATIC Teleservice Adapter IE Advanced
SiemensSIMATIC Teleservice Adapter IE Basic
SiemensSIMATIC Teleservice Adapter IE Standard
SiemensSIMATIC WinAC RTX 2010
SiemensSIMATIC WinAC RTX F 2010
SiemensSIMOCODE pro V PROFINET (incl. SIPLUS variants)
SiemensSIMOTION
SiemensSINAMICS DCM w. PN
SiemensSINAMICS DCP w. PN
SiemensSINAMICS G110M w. PN
SiemensSINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants)
SiemensSINAMICS G130 V4.7 w. PN
SiemensSINAMICS G130 V4.8 w. PN
SiemensSINAMICS G150 V4.7 w. PN
SiemensSINAMICS G150 V4.8 w. PN
SiemensSINAMICS S110 w. PN
SiemensSINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants)
SiemensSINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants)
SiemensSINAMICS S120 V4.7 w. PN (incl. SIPLUS variants)
SiemensSINAMICS S120 V4.8 w. PN (incl. SIPLUS variants)
SiemensSINAMICS S150 V4.7 w. PN
SiemensSINAMICS S150 V4.8 w. PN
SiemensSINAMICS V90 w. PN
SiemensSINUMERIK 828D V4.5 and prior
SiemensSINUMERIK 828D V4.7
SiemensSINUMERIK 840D sl V4.5 and prior
SiemensSINUMERIK 840D sl V4.7
SiemensSIPLUS ET 200MP IM 155-5 PN HF
SiemensSIPLUS ET 200MP IM 155-5 PN HF
SiemensSIPLUS ET 200MP IM 155-5 PN HF T1 RAIL
SiemensSIPLUS ET 200MP IM 155-5 PN ST
SiemensSIPLUS ET 200MP IM 155-5 PN ST TX RAIL
SiemensSIPLUS ET 200SP IM 155-6 PN HF
SiemensSIPLUS ET 200SP IM 155-6 PN HF
SiemensSIPLUS ET 200SP IM 155-6 PN HF T1 RAIL
SiemensSIPLUS ET 200SP IM 155-6 PN ST
SiemensSIPLUS ET 200SP IM 155-6 PN ST BA
SiemensSIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL
SiemensSIPLUS ET 200SP IM 155-6 PN ST TX RAIL
SiemensSIRIUS ACT 3SU1 interface module PROFINET
SiemensSIRIUS Motor Starter M200D PROFINET
SiemensSIRIUS Soft Starter 3RW44 PN
SiemensSITOP PSU8600 PROFINET
SiemensSITOP UPS1600 PROFINET (incl. SIPLUS variants)
SiemensSoftnet PROFINET IO for PC-based Windows systems
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2017-2681",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-23T20:22:19.045364Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-23T20:22:26.181Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T14:02:07.386Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "1038463",
            "tags": [
              "vdb-entry",
              "x_refsource_SECTRACK",
              "x_transferred"
            ],
            "url": "http://www.securitytracker.com/id/1038463"
          },
          {
            "name": "98369",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/98369"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.1 Patch04"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.2.1 Patch03"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4.0 Patch01"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IE/AS-i Link PN IO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IE/PB-Link (incl. SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M-800 family (incl. S615, MUM-800 and RM1224)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.03"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W-700 IEEE 802.11n family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X-200 family (incl. SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X-200IRT family (incl. SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.4.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X-300 family (incl. X408 and SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X408 family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X414",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.10.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM-400 family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR-500 family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CM 1542-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CM 1542SP-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.0.15"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1.82"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-8 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1.82"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1542SP-1 IRC (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.0.15"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1543-1 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1543SP-1 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.0.15"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1604",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1616",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 343-1 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.1.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 343-1 Advanced (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 343-1 Lean (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.1.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1 Advanced (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1 OPC UA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC DK-16xx PN IO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200AL IM 157-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V1.0.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200M (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200MP IM 155-5 PN BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.0.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200MP IM 155-5 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200MP IM 155-5 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM 154-3 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM 154-4 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN HS",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.0.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN ST BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 4AO U/I 4xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN: IO-Link Master",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200S (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC HMI Comfort Panels, HMI Multi Panels, HMI Mobile Panels (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV420 SR-B",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV420 SR-B Body",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV420 SR-P",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV420 SR-P Body",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV440 HR",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV440 SR",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV440 UR",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PN/PN Coupler (incl. SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC RF650R",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC RF680R",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC RF685R",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 Software Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-200 SMART",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.X.14",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0.7",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-410 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC TDC CP51M1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V1.1.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC TDC CPU555",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V1.1.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Teleservice Adapter IE Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Teleservice Adapter IE Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Teleservice Adapter IE Standard",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinAC RTX 2010",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2010 SP3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinAC RTX F 2010",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2010 SP3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOCODE pro V PROFINET (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTION",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.5 HF1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS DCM w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.4 SP1 HF5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS DCP w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.2 HF1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G110M w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 SP6 HF3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 SP6 HF3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G130 V4.7 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 HF27"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G130 V4.8 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 HF4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G150 V4.7 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "V4.7: All versions \u003c V4.7 HF27"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G150 V4.8 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 HF4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S110 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4 SP3 HF5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 V4.7 w. PN (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 HF27"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 V4.8 w. PN (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 HF4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S150 V4.7 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 HF27"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S150 V4.8 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 HF4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS V90 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.01"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINUMERIK 828D V4.5 and prior",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.5 SP6 HF2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINUMERIK 828D V4.7",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 SP4 HF1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINUMERIK 840D sl V4.5 and prior",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.5 SP6 HF2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINUMERIK 840D sl V4.7",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 SP4 HF1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN ST TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIRIUS ACT 3SU1 interface module PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.1.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIRIUS Motor Starter M200D PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIRIUS Soft Starter 3RW44 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SITOP PSU8600 PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SITOP UPS1600 PROFINET (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Softnet PROFINET IO for PC-based Windows systems",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14 SP1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-400",
              "description": "CWE-400: Uncontrolled Resource Consumption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-10T09:33:20.658Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "name": "1038463",
          "tags": [
            "vdb-entry",
            "x_refsource_SECTRACK"
          ],
          "url": "http://www.securitytracker.com/id/1038463"
        },
        {
          "name": "98369",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/98369"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2017-2681",
    "datePublished": "2017-05-11T10:00:00",
    "dateReserved": "2016-12-01T00:00:00",
    "dateUpdated": "2024-09-10T09:33:20.658Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",