All the vulnerabilites related to Siemens - SINUMERIK 828D V4
cve-2024-41171
Vulnerability from cvelistv5
Published
2024-09-10 09:36
Modified
2024-09-10 15:03
Severity ?
8.8 (High) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C
9.3 (Critical) - CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H
9.3 (Critical) - CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H
EPSS score ?
Summary
A vulnerability has been identified in SINUMERIK 828D V4 (All versions), SINUMERIK 828D V5 (All versions < V5.24), SINUMERIK 840D sl V4 (All versions), SINUMERIK ONE (All versions < V6.24). Affected devices do not properly enforce access restrictions to scripts that are regularly executed by the system with elevated privileges. This could allow an authenticated local attacker to escalate their privileges in the underlying system.
References
Impacted products
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:siemens:sinumerik_840d_sl_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinumerik_840d_sl_firmware", "vendor": "siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "4.0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:sinumerik_one_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinumerik_one_firmware", "vendor": "siemens", "versions": [ { "lessThan": "6.24", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:sinumerik_828d_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinumerik_828d_firmware", "vendor": "siemens", "versions": [ { "lessThan": "5.24", "status": "affected", "version": "4.0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-41171", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-09-10T14:54:43.895216Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-09-10T15:03:16.367Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SINUMERIK 828D V4", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK 828D V5", "vendor": "Siemens", "versions": [ { "lessThan": "V5.24", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK 840D sl V4", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK ONE", "vendor": "Siemens", "versions": [ { "lessThan": "V6.24", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SINUMERIK 828D V4 (All versions), SINUMERIK 828D V5 (All versions \u003c V5.24), SINUMERIK 840D sl V4 (All versions), SINUMERIK ONE (All versions \u003c V6.24). Affected devices do not properly enforce access restrictions to scripts that are regularly executed by the system with elevated privileges. This could allow an authenticated local attacker to escalate their privileges in the underlying system." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 9.3, "baseSeverity": "CRITICAL", "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-732", "description": "CWE-732: Incorrect Permission Assignment for Critical Resource", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-09-10T09:36:46.244Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-342438.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2024-41171", "datePublished": "2024-09-10T09:36:46.244Z", "dateReserved": "2024-07-17T13:37:58.435Z", "dateUpdated": "2024-09-10T15:03:16.367Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-43781
Vulnerability from cvelistv5
Published
2024-09-10 09:36
Modified
2024-09-10 14:38
Severity ?
5.5 (Medium) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C
6.8 (Medium) - CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N
6.8 (Medium) - CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N
EPSS score ?
Summary
A vulnerability has been identified in SINUMERIK 828D V4 (All versions < V4.95 SP3), SINUMERIK 840D sl V4 (All versions < V4.95 SP3 in connection with using Create MyConfig (CMC) <= V4.8 SP1 HF6), SINUMERIK ONE (All versions < V6.23 in connection with using Create MyConfig (CMC) <= V6.6), SINUMERIK ONE (All versions < V6.15 SP4 in connection with using Create MyConfig (CMC) <= V6.6). Affected systems, that have been provisioned with Create MyConfig (CMC), contain a Insertion of Sensitive Information into Log File vulnerability. This could allow a local authenticated user with low privileges to read sensitive information and thus circumvent access restrictions.
References
Impacted products
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-43781", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-09-10T14:38:29.713747Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-09-10T14:38:36.778Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SINUMERIK 828D V4", "vendor": "Siemens", "versions": [ { "lessThan": "V4.95 SP3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK 840D sl V4", "vendor": "Siemens", "versions": [ { "lessThan": "V4.95 SP3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK ONE", "vendor": "Siemens", "versions": [ { "lessThan": "V6.23", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK ONE", "vendor": "Siemens", "versions": [ { "lessThan": "V6.15 SP4", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SINUMERIK 828D V4 (All versions \u003c V4.95 SP3), SINUMERIK 840D sl V4 (All versions \u003c V4.95 SP3 in connection with using Create MyConfig (CMC) \u003c= V4.8 SP1 HF6), SINUMERIK ONE (All versions \u003c V6.23 in connection with using Create MyConfig (CMC) \u003c= V6.6), SINUMERIK ONE (All versions \u003c V6.15 SP4 in connection with using Create MyConfig (CMC) \u003c= V6.6). Affected systems, that have been provisioned with Create MyConfig (CMC), contain a Insertion of Sensitive Information into Log File vulnerability. This could allow a local authenticated user with low privileges to read sensitive information and thus circumvent access restrictions." } ], "metrics": [ { "cvssV3_1": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 6.8, "baseSeverity": "MEDIUM", "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-532", "description": "CWE-532: Insertion of Sensitive Information into Log File", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-09-10T09:36:51.143Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-097786.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2024-43781", "datePublished": "2024-09-10T09:36:51.143Z", "dateReserved": "2024-08-16T10:13:58.486Z", "dateUpdated": "2024-09-10T14:38:36.778Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }