All the vulnerabilites related to Siemens AG - SINUMERIK 840D sl
cve-2019-18336
Vulnerability from cvelistv5
Published
2020-03-10 19:16
Modified
2024-08-05 01:54
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V3.X.17), SIMATIC TDC CP51M1 (All versions < V1.1.8), SIMATIC TDC CPU555 (All versions < V1.1.1), SINUMERIK 840D sl (All versions < V4.8.6), SINUMERIK 840D sl (All versions < V4.94). Specially crafted packets sent to port 102/tcp (Profinet) could cause the affected device to go into defect mode. A restart is required in order to recover the system. Successful exploitation requires an attacker to have network access to port 102/tcp, with no authentication. No user interation is required. At the time of advisory publication no public exploitation of this security vulnerability was known.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-508982.pdf | x_refsource_MISC |
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T01:54:14.382Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-508982.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V3.X.17" } ] }, { "product": "SIMATIC TDC CP51M1", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V1.1.8" } ] }, { "product": "SIMATIC TDC CPU555", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V1.1.1" } ] }, { "product": "SINUMERIK 840D sl", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8.6" } ] }, { "product": "SINUMERIK 840D sl", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V4.94" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V3.X.17), SIMATIC TDC CP51M1 (All versions \u003c V1.1.8), SIMATIC TDC CPU555 (All versions \u003c V1.1.1), SINUMERIK 840D sl (All versions \u003c V4.8.6), SINUMERIK 840D sl (All versions \u003c V4.94). Specially crafted packets sent to port 102/tcp (Profinet) could cause the affected device to go into defect mode. A restart is required in order to recover the system. Successful exploitation requires an attacker to have network access to port 102/tcp, with no authentication. No user interation is required. At the time of advisory publication no public exploitation of this security vulnerability was known." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400: Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-07-14T13:18:04", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-508982.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2019-18336", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V3.X.17" } ] } }, { "product_name": "SIMATIC TDC CP51M1", "version": { "version_data": [ { "version_value": "All versions \u003c V1.1.8" } ] } }, { "product_name": "SIMATIC TDC CPU555", "version": { "version_data": [ { "version_value": "All versions \u003c V1.1.1" } ] } }, { "product_name": "SINUMERIK 840D sl", "version": { "version_data": [ { "version_value": "All versions \u003c V4.8.6" } ] } }, { "product_name": "SINUMERIK 840D sl", "version": { "version_data": [ { "version_value": "All versions \u003c V4.94" } ] } } ] }, "vendor_name": "Siemens AG" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V3.X.17), SIMATIC TDC CP51M1 (All versions \u003c V1.1.8), SIMATIC TDC CPU555 (All versions \u003c V1.1.1), SINUMERIK 840D sl (All versions \u003c V4.8.6), SINUMERIK 840D sl (All versions \u003c V4.94). Specially crafted packets sent to port 102/tcp (Profinet) could cause the affected device to go into defect mode. A restart is required in order to recover the system. Successful exploitation requires an attacker to have network access to port 102/tcp, with no authentication. No user interation is required. At the time of advisory publication no public exploitation of this security vulnerability was known." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-400: Uncontrolled Resource Consumption" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-508982.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-508982.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2019-18336", "datePublished": "2020-03-10T19:16:17", "dateReserved": "2019-10-23T00:00:00", "dateUpdated": "2024-08-05T01:54:14.382Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }