All the vulnerabilites related to WAGO - Series Touch Panel 600 Marine Line (762-6xxx)
cve-2022-22511
Vulnerability from cvelistv5
Published
2022-03-09 19:38
Modified
2024-09-17 00:16
Summary
WAGO PLCs WBM vulnerable to reflected XSS
References
https://cert.vde.com/en/advisories/VDE-2022-004/x_refsource_CONFIRM
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T03:14:55.300Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert.vde.com/en/advisories/VDE-2022-004/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Compact Controller CC100 (751-9301)",
          "vendor": "WAGO",
          "versions": [
            {
              "lessThan": "FW22",
              "status": "affected",
              "version": "FW16",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Edge Controller (752-8303/8000-002)",
          "vendor": "WAGO",
          "versions": [
            {
              "lessThan": "FW22",
              "status": "affected",
              "version": "FW16",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Series PFC100 (750-81xx/xxx-xxx)",
          "vendor": "WAGO",
          "versions": [
            {
              "lessThan": "FW22",
              "status": "affected",
              "version": "FW16",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Series PFC200 (750-82xx/xxx-xxx)",
          "vendor": "WAGO",
          "versions": [
            {
              "lessThan": "FW22",
              "status": "affected",
              "version": "FW16",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Series Touch Panel 600 Advanced Line (762-5xxx)",
          "vendor": "WAGO",
          "versions": [
            {
              "status": "affected",
              "version": "FW16 FW22"
            }
          ]
        },
        {
          "product": "Series Touch Panel 600 Marine Line (762-6xxx)",
          "vendor": "WAGO",
          "versions": [
            {
              "status": "affected",
              "version": "FW16 FW22"
            }
          ]
        },
        {
          "product": "Series Touch Panel 600 Standard Line (762-4xxx)",
          "vendor": "WAGO",
          "versions": [
            {
              "status": "affected",
              "version": "FW16 FW22"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "These vulnerabilities were reported to WAGO by: Mohamed Magdy Abumuslim, coordination done by CERT@VDE."
        }
      ],
      "datePublic": "2022-03-09T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Various configuration pages of the device are vulnerable to reflected XSS (Cross-Site Scripting) attacks. An authorized attacker with user privileges may use this to gain access to confidential information on a PC that connects to the WBM after it has been compromised."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Cross-site Scripting (XSS)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-09T19:38:43",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2022-004/"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Install FW \u003e=FW22 (FW22 planned for end of Q2/22)"
        }
      ],
      "source": {
        "advisory": "VDE-2022-004",
        "defect": [
          "CERT@VDE#64068"
        ],
        "discovery": "EXTERNAL"
      },
      "title": "WAGO PLCs WBM vulnerable to reflected XSS",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "info@cert.vde.com",
          "DATE_PUBLIC": "2022-03-09T07:00:00.000Z",
          "ID": "CVE-2022-22511",
          "STATE": "PUBLIC",
          "TITLE": "WAGO PLCs WBM vulnerable to reflected XSS"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Compact Controller CC100 (751-9301)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "FW16",
                            "version_value": "FW22"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Edge Controller (752-8303/8000-002)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "FW16",
                            "version_value": "FW22"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Series PFC100 (750-81xx/xxx-xxx)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "FW16",
                            "version_value": "FW22"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Series PFC200 (750-82xx/xxx-xxx)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "FW16",
                            "version_value": "FW22"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Series Touch Panel 600 Advanced Line (762-5xxx)",
                      "version": {
                        "version_data": [
                          {
                            "version_name": "FW16",
                            "version_value": "FW22"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Series Touch Panel 600 Marine Line (762-6xxx)",
                      "version": {
                        "version_data": [
                          {
                            "version_name": "FW16",
                            "version_value": "FW22"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Series Touch Panel 600 Standard Line (762-4xxx)",
                      "version": {
                        "version_data": [
                          {
                            "version_name": "FW16",
                            "version_value": "FW22"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "WAGO"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "These vulnerabilities were reported to WAGO by: Mohamed Magdy Abumuslim, coordination done by CERT@VDE."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Various configuration pages of the device are vulnerable to reflected XSS (Cross-Site Scripting) attacks. An authorized attacker with user privileges may use this to gain access to confidential information on a PC that connects to the WBM after it has been compromised."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-79 Cross-site Scripting (XSS)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert.vde.com/en/advisories/VDE-2022-004/",
              "refsource": "CONFIRM",
              "url": "https://cert.vde.com/en/advisories/VDE-2022-004/"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Install FW \u003e=FW22 (FW22 planned for end of Q2/22)"
          }
        ],
        "source": {
          "advisory": "VDE-2022-004",
          "defect": [
            "CERT@VDE#64068"
          ],
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2022-22511",
    "datePublished": "2022-03-09T19:38:43.516457Z",
    "dateReserved": "2022-01-03T00:00:00",
    "dateUpdated": "2024-09-17T00:16:00.059Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}