All the vulnerabilites related to Mitsubishi Electric - Setting/monitoring tools for the C Controller module
cve-2020-14496
Vulnerability from cvelistv5
Published
2022-05-19 17:24
Modified
2024-08-04 12:46
Severity ?
EPSS score ?
Summary
Successful exploitation of this vulnerability for multiple Mitsubishi Electric Factory Automation Engineering Software Products of various versions could allow an attacker to escalate privilege and execute malicious programs, which could cause a denial-of-service condition, and allow information to be disclosed, tampered with, and/or destroyed.
References
▼ | URL | Tags |
---|---|---|
https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-02 | x_refsource_MISC |
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T12:46:34.676Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-02" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "CPU Module Logging Configuration Tool", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "1.100E", "status": "affected", "version": "All", "versionType": "custom" } ] }, { "product": "CW Configurator", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "1.010L", "status": "affected", "version": "All", "versionType": "custom" } ] }, { "product": "Data Transfer", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "3.40S", "status": "affected", "version": "All", "versionType": "custom" } ] }, { "product": "EZSocket", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "4.5", "status": "affected", "version": "All", "versionType": "custom" } ] }, { "product": "FR Configurator2", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "1.22Y", "status": "affected", "version": "All", "versionType": "custom" } ] }, { "product": "GT Designer3 Version1 (GOT2000)", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "1.235V", "status": "affected", "version": "All", "versionType": "custom" } ] }, { "product": "GT SoftGOT1000 Version3", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "3.200J", "status": "affected", "version": "All", "versionType": "custom" } ] }, { "product": "GT SoftGOT1000 Version3", "vendor": "Mitsubishi Electric", "versions": [ { "status": "affected", "version": "All" } ] }, { "product": "GT SoftGOT2000 Version1", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "1.235V", "status": "affected", "version": "All", "versionType": "custom" } ] }, { "product": "GX LogViewer", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "1.100E", "status": "affected", "version": "All", "versionType": "custom" } ] }, { "product": "GX Works2", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "1.592S", "status": "affected", "version": "All", "versionType": "custom" } ] }, { "product": "GX Works3", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "1.063R", "status": "affected", "version": "All", "versionType": "custom" } ] }, { "product": "M_CommDTM-HART", "vendor": "Mitsubishi Electric", "versions": [ { "status": "affected", "version": "All 1.00A" } ] }, { "product": "M_CommDTM-IO-Link", "vendor": "Mitsubishi Electric", "versions": [ { "status": "affected", "version": "All" } ] }, { "product": "MELFA-Works", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "4.3", "status": "affected", "version": "All", "versionType": "custom" } ] }, { "product": "MELSEC WinCPU Setting Utility", "vendor": "Mitsubishi Electric", "versions": [ { "status": "affected", "version": "All" } ] }, { "product": "MELSOFT EM Software Development Kit (EM Configurator)", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "1.010L", "status": "affected", "version": "All", "versionType": "custom" } ] }, { "product": "MELSOFT FieldDeviceConfigurator", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "1.03D", "status": "affected", "version": "All", "versionType": "custom" } ] }, { "product": "MELSOFT Navigator", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "2.62Q", "status": "affected", "version": "All", "versionType": "custom" } ] }, { "product": "MH11 SettingTool Version2", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "2.002C", "status": "affected", "version": "All", "versionType": "custom" } ] }, { "product": "MI Configurator", "vendor": "Mitsubishi Electric", "versions": [ { "status": "affected", "version": "All" } ] }, { "product": "Motorizer", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "1.005F", "status": "affected", "version": "All", "versionType": "custom" } ] }, { "product": "MR Configurator2", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "1.105K", "status": "affected", "version": "All", "versionType": "custom" } ] }, { "product": "MT Works2", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "1.156N", "status": "affected", "version": "All", "versionType": "custom" } ] }, { "product": "MX Component", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "4.19V", "status": "affected", "version": "All", "versionType": "custom" } ] }, { "product": "Network Interface Board CC IE Control utility", "vendor": "Mitsubishi Electric", "versions": [ { "status": "affected", "version": "All" } ] }, { "product": "Network Interface Board CC IE Field Utility", "vendor": "Mitsubishi Electric", "versions": [ { "status": "affected", "version": "All" } ] }, { "product": "Network Interface Board CC-Link Ver.2 Utility", "vendor": "Mitsubishi Electric", "versions": [ { "status": "affected", "version": "All" } ] }, { "product": "Network Interface Board MNETH utility", "vendor": "Mitsubishi Electric", "versions": [ { "status": "affected", "version": "All" } ] }, { "product": "PX Developer", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "1.52E", "status": "affected", "version": "All", "versionType": "custom" } ] }, { "product": "RT ToolBox2", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "3.72A", "status": "affected", "version": "All", "versionType": "custom" } ] }, { "product": "RT ToolBox3", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "1.70Y", "status": "affected", "version": "All", "versionType": "custom" } ] }, { "product": "Setting/monitoring tools for the C Controller module", "vendor": "Mitsubishi Electric", "versions": [ { "status": "affected", "version": "All" } ] } ], "descriptions": [ { "lang": "en", "value": "Successful exploitation of this vulnerability for multiple Mitsubishi Electric Factory Automation Engineering Software Products of various versions could allow an attacker to escalate privilege and execute malicious programs, which could cause a denial-of-service condition, and allow information to be disclosed, tampered with, and/or destroyed." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.3, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-275", "description": "CWE-275 Permission Issues", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-05-19T17:24:43", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-02" } ], "source": { "advisory": "ICSA-20-212-02", "discovery": "UNKNOWN" }, "title": "Mitsubishi Electric Multiple Factory Automation Engineering Software Products (Update A) - Permission Issues", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2020-14496", "STATE": "PUBLIC", "TITLE": "Mitsubishi Electric Multiple Factory Automation Engineering Software Products (Update A) - Permission Issues" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "CPU Module Logging Configuration Tool", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "All", "version_value": "1.100E" } ] } }, { "product_name": "CW Configurator", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "All", "version_value": "1.010L" } ] } }, { "product_name": "Data Transfer", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "All", "version_value": "3.40S" } ] } }, { "product_name": "EZSocket", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "All", "version_value": "4.5" } ] } }, { "product_name": "FR Configurator2", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "All", "version_value": "1.22Y" } ] } }, { "product_name": "GT Designer3 Version1 (GOT2000)", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "All", "version_value": "1.235V" } ] } }, { "product_name": "GT SoftGOT1000 Version3", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "All", "version_value": "3.200J" } ] } }, { "product_name": "GT SoftGOT1000 Version3", "version": { "version_data": [ { "version_affected": "=", "version_name": "All", "version_value": "All" } ] } }, { "product_name": "GT SoftGOT2000 Version1", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "All", "version_value": "1.235V" } ] } }, { "product_name": "GX LogViewer", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "All", "version_value": "1.100E" } ] } }, { "product_name": "GX Works2", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "All", "version_value": "1.592S" } ] } }, { "product_name": "GX Works3", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "All", "version_value": "1.063R" } ] } }, { "product_name": "M_CommDTM-HART", "version": { "version_data": [ { "version_affected": "=", "version_name": "All", "version_value": "1.00A" } ] } }, { "product_name": "M_CommDTM-IO-Link", "version": { "version_data": [ { "version_affected": "=", "version_name": "All", "version_value": "All" } ] } }, { "product_name": "MELFA-Works", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "All", "version_value": "4.3" } ] } }, { "product_name": "MELSEC WinCPU Setting Utility", "version": { "version_data": [ { "version_affected": "=", "version_name": "All", "version_value": "All" } ] } }, { "product_name": "MELSOFT EM Software Development Kit (EM Configurator)", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "All", "version_value": "1.010L" } ] } }, { "product_name": "MELSOFT FieldDeviceConfigurator", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "All", "version_value": "1.03D" } ] } }, { "product_name": "MELSOFT Navigator", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "All", "version_value": "2.62Q" } ] } }, { "product_name": "MH11 SettingTool Version2", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "All", "version_value": "2.002C" } ] } }, { "product_name": "MI Configurator", "version": { "version_data": [ { "version_affected": "=", "version_name": "All", "version_value": "All" } ] } }, { "product_name": "Motorizer", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "All", "version_value": "1.005F" } ] } }, { "product_name": "MR Configurator2", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "All", "version_value": "1.105K" } ] } }, { "product_name": "MT Works2", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "All", "version_value": "1.156N" } ] } }, { "product_name": "MX Component", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "All", "version_value": "4.19V" } ] } }, { "product_name": "Network Interface Board CC IE Control utility", "version": { "version_data": [ { "version_affected": "=", "version_name": "All", "version_value": "All" } ] } }, { "product_name": "Network Interface Board CC IE Field Utility", "version": { "version_data": [ { "version_affected": "=", "version_name": "All", "version_value": "All" } ] } }, { "product_name": "Network Interface Board CC-Link Ver.2 Utility", "version": { "version_data": [ { "version_affected": "=", "version_name": "All", "version_value": "All" } ] } }, { "product_name": "Network Interface Board MNETH utility", "version": { "version_data": [ { "version_affected": "=", "version_name": "All", "version_value": "All" } ] } }, { "product_name": "PX Developer", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "All", "version_value": "1.52E" } ] } }, { "product_name": "RT ToolBox2", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "All", "version_value": "3.72A" } ] } }, { "product_name": "RT ToolBox3", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "All", "version_value": "1.70Y" } ] } }, { "product_name": "Setting/monitoring tools for the C Controller module", "version": { "version_data": [ { "version_affected": "=", "version_name": "All", "version_value": "All" } ] } } ] }, "vendor_name": "Mitsubishi Electric" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Successful exploitation of this vulnerability for multiple Mitsubishi Electric Factory Automation Engineering Software Products of various versions could allow an attacker to escalate privilege and execute malicious programs, which could cause a denial-of-service condition, and allow information to be disclosed, tampered with, and/or destroyed." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.3, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-275 Permission Issues" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-02", "refsource": "MISC", "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-02" } ] }, "source": { "advisory": "ICSA-20-212-02", "discovery": "UNKNOWN" } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2020-14496", "datePublished": "2022-05-19T17:24:43", "dateReserved": "2020-06-19T00:00:00", "dateUpdated": "2024-08-04T12:46:34.676Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-14521
Vulnerability from cvelistv5
Published
2022-02-11 17:40
Modified
2024-09-16 23:45
Severity ?
EPSS score ?
Summary
Multiple Mitsubishi Electric Factory Automation engineering software products have a malicious code execution vulnerability. A malicious attacker could use this vulnerability to obtain information, modify information, and cause a denial-of-service condition.
References
▼ | URL | Tags |
---|---|---|
https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-04 | government-resource | |
https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-007_en.pdf | vendor-advisory |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Mitsubishi Electric | C Controller Interface Module Utility |
Version: unspecified < |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T12:46:34.835Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "government-resource", "x_transferred" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-04" }, { "tags": [ "vendor-advisory", "x_transferred" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-007_en.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "C Controller Interface Module Utility", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 2.00", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "CC-Link IE Control Network Data Collector", "vendor": "Mitsubishi Electric", "versions": [ { "status": "affected", "version": "Version 1.00A" } ] }, { "defaultStatus": "unaffected", "product": "CC-Link IE Field Network Data Collector", "vendor": "Mitsubishi Electric", "versions": [ { "status": "affected", "version": "Version 1.00A" } ] }, { "defaultStatus": "unaffected", "product": "CC-Link IE TSN Data Collector", "vendor": "Mitsubishi Electric", "versions": [ { "status": "affected", "version": "Version 1.00A" } ] }, { "defaultStatus": "unaffected", "product": "CPU Module Logging Configuration Tool", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.100E", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "CW Configurator", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.010L", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Data Transfer", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 3.42U", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "EZSocket", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 5.1", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "FR Configurator SW3", "vendor": "Mitsubishi Electric", "versions": [ { "status": "affected", "version": "All Versions" } ] }, { "defaultStatus": "unaffected", "product": "FR Configurator2", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.26C", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "GT Designer2 Classic", "vendor": "Mitsubishi Electric", "versions": [ { "status": "affected", "version": "All Versions" } ] }, { "defaultStatus": "unaffected", "product": "GT Designer3 Version1 (GOT1000)", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.241B", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "GT Designer3 Version1 (GOT2000)", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.241B", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "GT SoftGOT1000 Version3", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 3.200J", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "GT SoftGOT2000 Version1", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.241B", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "GX Developer", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 8.504A", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "GX LogViewer", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.100E", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "GX Works2", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.601B", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "GX Works3", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.063R", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "M_CommDTM-IO-Link", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.03D", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "MELFA-Works", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 4.4", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "MELSEC WinCPU Setting Utility", "vendor": "Mitsubishi Electric", "versions": [ { "status": "affected", "version": "All Versions" } ] }, { "defaultStatus": "unaffected", "product": "MELSOFT Complete Clean Up Tool", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.06G", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "MELSOFT EM Software Development Kit", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.015R", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "MELSOFT iQ AppPortal", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.17T", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "MELSOFT Navigator", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 2.74C", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "MI Configurator", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.004E", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Motion Control Setting", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.005F", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Motorizer", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.005F", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "MR Configurator2", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.125F", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "MT Works2", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.167Z", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "MTConnect Data Collector", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.1.4.0", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "MX Component", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 4.20W", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "MX MESInterface", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.21X", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "MX MESInterface-R", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.12N", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "MX Sheet", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 2.15R", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Network Interface Board CC IE Control Utility", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.29F", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Network Interface Board CC IE Field Utility", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Versions 1.16S", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Network Interface Board CC-Link Ver.2 Utility", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.23Z", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Network Interface Board MNETH Utility", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 34L", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Position Board utility 2", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 3.20", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "PX Developer", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.53F", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "RT ToolBox2", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 3.73B", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "RT ToolBox3", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.82L", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Setting/Monitoring tools for the C Controller module", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "SW3PVC-CCPU Version 3.13P", "status": "affected", "version": "unspecified", "versionType": "custom" }, { "lessThanOrEqual": "SW4PVC-CCPU Version 4.12N", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "SLMP Data Collector", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.04E", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "user": "00000000-0000-4000-9000-000000000000", "value": "Mashav Sapir of Claroty reported this vulnerability to CISA" } ], "datePublic": "2020-07-30T06:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Multiple Mitsubishi Electric Factory Automation engineering software products have a malicious code execution vulnerability. A malicious attacker could use this vulnerability to obtain information, modify information, and cause a denial-of-service condition.\n\n\u003cp\u003e\u003c/p\u003e" } ], "value": "Multiple Mitsubishi Electric Factory Automation engineering software products have a malicious code execution vulnerability. A malicious attacker could use this vulnerability to obtain information, modify information, and cause a denial-of-service condition." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.3, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-428", "description": "CWE-428 Unquoted Search Path or Element", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-03-07T21:29:25.280Z", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "government-resource" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-04" }, { "tags": [ "vendor-advisory" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-007_en.pdf" } ], "source": { "advisory": "ICSA-20-212-04", "discovery": "UNKNOWN" }, "title": "Mitsubishi Electric Factory Automation Engineering Products Unquoted Search Path or Element", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "DATE_PUBLIC": "2020-07-30T16:50:00.000Z", "ID": "CVE-2020-14521", "STATE": "PUBLIC", "TITLE": "Mitsubishi Electric Factory Automation Engineering Products Unquoted Search Path or Element" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "C Controller Interface Module Utility", "version": { "version_data": [ { "version_affected": "=", "version_value": "All Versions" } ] } }, { "product_name": "C Controller Module Setting and Monitoring Tool", "version": { "version_data": [ { "version_affected": "=", "version_value": "All Versions" } ] } }, { "product_name": "CC-Link IE Control Network Data Collector", "version": { "version_data": [ { "version_affected": "=", "version_value": "Version 1.00A" } ] } }, { "product_name": "CC-Link IE Field Network Data Collector", "version": { "version_data": [ { "version_affected": "=", "version_value": "Version 1.00A" } ] } }, { "product_name": "CC-Link IE TSN Data Collector", "version": { "version_data": [ { "version_affected": "=", "version_value": "Version 1.00A" } ] } }, { "product_name": "CPU Module Logging Configuration Tool", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 1.100E" } ] } }, { "product_name": "CW Configurator", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 1.010L" } ] } }, { "product_name": "Data Transfer", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 3.42U and prior" } ] } }, { "product_name": "EZSocket", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 5.1" } ] } }, { "product_name": "FR Configurator SW3", "version": { "version_data": [ { "version_affected": "=", "version_value": "All Versions" } ] } }, { "product_name": "FR Configurator2", "version": { "version_data": [ { "version_affected": "=", "version_value": "All Versions" } ] } }, { "product_name": "GT Designer2 Classic", "version": { "version_data": [ { "version_affected": "=", "version_value": "All Versions" } ] } }, { "product_name": "GT Designer3 Version1 (GOT1000)", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 1.241B" } ] } }, { "product_name": "GT Designer3 Version1 (GOT2000)", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 1.241B" } ] } }, { "product_name": "GT SoftGOT1000 Version3", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 3.200J" } ] } }, { "product_name": "GT SoftGOT2000 Version1", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 1.241B" } ] } }, { "product_name": "GX Developer", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 8.504A" } ] } }, { "product_name": "GX LogViewer", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 1.100E" } ] } }, { "product_name": "GX Works2", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 1.601B" } ] } }, { "product_name": "GX Works3", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 1.063R" } ] } }, { "product_name": "M_CommDTM-IO-Link", "version": { "version_data": [ { "version_affected": "=", "version_value": "All Versions" } ] } }, { "product_name": "MELFA-Works", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 4.4" } ] } }, { "product_name": "MELSEC WinCPU Setting Utility", "version": { "version_data": [ { "version_affected": "=", "version_value": "All Versions" } ] } }, { "product_name": "MELSOFT Complete Clean Up Tool", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 1.06G" } ] } }, { "product_name": "MELSOFT EM Software Development Kit", "version": { "version_data": [ { "version_affected": "=", "version_value": "All Versions" } ] } }, { "product_name": "MELSOFT iQ AppPortal", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 1.17T" } ] } }, { "product_name": "MELSOFT Navigator", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 2.74C" } ] } }, { "product_name": "MI Configurator", "version": { "version_data": [ { "version_affected": "=", "version_value": "All Versions" } ] } }, { "product_name": "Motion Control Setting", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 1.005F" } ] } }, { "product_name": "Motorizer", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 1.005F" } ] } }, { "product_name": "MR Configurator2", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 1.125F" } ] } }, { "product_name": "MT Works2", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 1.167Z" } ] } }, { "product_name": "MTConnect Data Collector", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 1.1.4.0" } ] } }, { "product_name": "MX Component", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 4.20W" } ] } }, { "product_name": "MX MESInterface", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 1.21X" } ] } }, { "product_name": "MX MESInterface-R", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 1.12N" } ] } }, { "product_name": "MX Sheet", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 2.15R" } ] } }, { "product_name": "Network Interface Board CC IE Control Utility", "version": { "version_data": [ { "version_affected": "=", "version_value": "All Versions" } ] } }, { "product_name": "Network Interface Board CC IE Field Utility", "version": { "version_data": [ { "version_affected": "=", "version_value": "All Versions" } ] } }, { "product_name": "Network Interface Board CC-Link Ver.2 Utility", "version": { "version_data": [ { "version_affected": "=", "version_value": "All Versions" } ] } }, { "product_name": "Network Interface Board MNETH Utility", "version": { "version_data": [ { "version_affected": "=", "version_value": "All Versions" } ] } }, { "product_name": "Position Board utility 2", "version": { "version_data": [ { "version_affected": "=", "version_value": "All Versions" } ] } }, { "product_name": "PX Developer", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "version 1.53F" } ] } }, { "product_name": "RT ToolBox2", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 3.73B" } ] } }, { "product_name": "RT ToolBox3", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 1.82L" } ] } }, { "product_name": "Setting/monitoring tools for the C Controller module", "version": { "version_data": [ { "version_affected": "=", "version_value": "All Versions" } ] } }, { "product_name": "SLMP Data Collector", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 1.04E" } ] } } ] }, "vendor_name": "Mitsubishi Electric" } ] } }, "credit": [ { "lang": "eng", "value": "Mashav Sapir of Claroty reported this vulnerability to CISA" } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Multiple Mitsubishi Electric Factory Automation engineering software products have a malicious code execution vulnerability. A malicious attacker could use this vulnerability to obtain information, modify information, and cause a denial-of-service condition." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.3, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-428 Unquoted Search Path or Element" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-04", "refsource": "MISC", "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-04" }, { "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-007_en.pdf", "refsource": "MISC", "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-007_en.pdf" } ] }, "solution": [ { "lang": "en" } ], "source": { "advisory": "ICSA-20-212-04", "discovery": "UNKNOWN" } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2020-14521", "datePublished": "2022-02-11T17:40:28.403703Z", "dateReserved": "2020-06-19T00:00:00", "dateUpdated": "2024-09-16T23:45:38.115Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }