All the vulnerabilites related to Siemens - Softnet PROFINET IO for PC-based Windows systems
cve-2018-4843
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T05:18:26.626Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-592007.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": " SIMATIC S7-400 CPU 414-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.0.3" } ] }, { "defaultStatus": "unknown", "product": " SIMATIC S7-400 CPU 414F-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.0.3" } ] }, { "defaultStatus": "unknown", "product": " SIMATIC S7-400 CPU 416-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.0.3" } ] }, { "defaultStatus": "unknown", "product": " SIMATIC S7-400 CPU 416F-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.0.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 343-1 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 343-1 Advanced (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 443-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 443-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 443-1 Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM154-8 PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM154-8F PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM154-8FX PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200S IM151-8 PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200S IM151-8F PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.7.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 Software Controller", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.7.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 314C-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 315-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 315F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 315T-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317T-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317TF-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 319-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 319F-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 CPU 412-2 PN V7", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.0.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.0.9" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.0.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-410 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V8.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinAC RTX 2010", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2010 SP3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinAC RTX F 2010", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2010 SP3" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK 828D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP6 HF1" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200S IM151-8 PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200S IM151-8F PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET CP 443-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET CP 443-1 Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 314C-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3.16" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 315-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 315F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 317-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 317F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-400 CPU 414-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.0.3" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-400 CPU 416-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.0.3" } ] }, { "defaultStatus": "unknown", "product": "Softnet PROFINET IO for PC-based Windows systems", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions \u003c V7.0.3), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions \u003c V7.0.3), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions \u003c V7.0.3), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions \u003c V7.0.3), SIMATIC CP 343-1 (incl. SIPLUS variants) (All versions), SIMATIC CP 343-1 Advanced (incl. SIPLUS variants) (All versions), SIMATIC CP 443-1 (All versions \u003c V3.3), SIMATIC CP 443-1 (All versions \u003c V3.3), SIMATIC CP 443-1 Advanced (All versions \u003c V3.3), SIMATIC ET 200pro IM154-8 PN/DP CPU (All versions \u003c V3.2.16), SIMATIC ET 200pro IM154-8F PN/DP CPU (All versions \u003c V3.2.16), SIMATIC ET 200pro IM154-8FX PN/DP CPU (All versions \u003c V3.2.16), SIMATIC ET 200S IM151-8 PN/DP CPU (All versions \u003c V3.2.16), SIMATIC ET 200S IM151-8F PN/DP CPU (All versions \u003c V3.2.16), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V1.7.0), SIMATIC S7-1500 Software Controller (All versions \u003c V1.7.0), SIMATIC S7-300 CPU 314C-2 PN/DP (All versions \u003c V3.3.16), SIMATIC S7-300 CPU 315-2 PN/DP (All versions \u003c V3.2.16), SIMATIC S7-300 CPU 315F-2 PN/DP (All versions \u003c V3.2.16), SIMATIC S7-300 CPU 315T-3 PN/DP (All versions \u003c V3.2.16), SIMATIC S7-300 CPU 317-2 PN/DP (All versions \u003c V3.2.16), SIMATIC S7-300 CPU 317F-2 PN/DP (All versions \u003c V3.2.16), SIMATIC S7-300 CPU 317T-3 PN/DP (All versions \u003c V3.2.16), SIMATIC S7-300 CPU 317TF-3 PN/DP (All versions \u003c V3.2.16), SIMATIC S7-300 CPU 319-3 PN/DP (All versions \u003c V3.2.16), SIMATIC S7-300 CPU 319F-3 PN/DP (All versions \u003c V3.2.16), SIMATIC S7-400 CPU 412-2 PN V7 (All versions \u003c V7.0.3), SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) (All versions \u003c V6.0.9), SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants) (All versions \u003c V6.0.7), SIMATIC S7-410 CPU family (incl. SIPLUS variants) (All versions \u003c V8.1), SIMATIC WinAC RTX 2010 (All versions \u003c V2010 SP3), SIMATIC WinAC RTX F 2010 (All versions \u003c V2010 SP3), SINUMERIK 828D (All versions \u003c V4.7 SP6 HF1), SIPLUS ET 200S IM151-8 PN/DP CPU (All versions \u003c V3.2.16), SIPLUS ET 200S IM151-8F PN/DP CPU (All versions \u003c V3.2.16), SIPLUS NET CP 443-1 (All versions \u003c V3.3), SIPLUS NET CP 443-1 Advanced (All versions \u003c V3.3), SIPLUS S7-300 CPU 314C-2 PN/DP (All versions \u003c V3.3.16), SIPLUS S7-300 CPU 315-2 PN/DP (All versions \u003c V3.2.16), SIPLUS S7-300 CPU 315F-2 PN/DP (All versions \u003c V3.2.16), SIPLUS S7-300 CPU 317-2 PN/DP (All versions \u003c V3.2.16), SIPLUS S7-300 CPU 317F-2 PN/DP (All versions \u003c V3.2.16), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions \u003c V7.0.3), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions \u003c V7.0.3), Softnet PROFINET IO for PC-based Windows systems (All versions). Responding to a PROFINET DCP request with a specially crafted PROFINET DCP packet could cause a denial of service condition of the requesting system.\r\n\r\nThe security vulnerability could be exploited by an attacker located on the same Ethernet segment (OSI Layer 2) as the targeted device. A manual restart is required to recover the system." } ], "metrics": [ { "cvssV3_1": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-20", "description": "CWE-20: Improper Input Validation", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-05-09T11:50:59.460Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-592007.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2018-4843", "datePublished": "2018-03-20T14:00:00", "dateReserved": "2018-01-02T00:00:00", "dateUpdated": "2024-08-05T05:18:26.626Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2017-2680
Vulnerability from cvelistv5
7.1 (High) - CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N
▼ | URL | Tags |
---|---|---|
http://www.securitytracker.com/id/1038463 | vdb-entry, x_refsource_SECTRACK | |
http://www.securityfocus.com/bid/98369 | vdb-entry, x_refsource_BID | |
https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf | x_refsource_CONFIRM | |
https://ics-cert.us-cert.gov/advisories/ICSA-18-023-02 | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf | x_refsource_CONFIRM | |
https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdf | x_refsource_CONFIRM | |
https://cert-portal.siemens.com/productcert/pdf/ssa-284673.pdf | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/html/ssa-293562.html | ||
https://cert-portal.siemens.com/productcert/html/ssa-284673.html | ||
https://cert-portal.siemens.com/productcert/html/ssa-546832.html |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2017-2680", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-07-09T13:26:04.237652Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-07-09T13:26:15.327Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-05T14:02:07.270Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "1038463", "tags": [ "vdb-entry", "x_refsource_SECTRACK", "x_transferred" ], "url": "http://www.securitytracker.com/id/1038463" }, { "name": "98369", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/98369" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-023-02" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-284673.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-284673.html" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-546832.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.1 Patch04" } ] }, { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.2.1 Patch03" } ] }, { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4.0 Patch01" } ] }, { "defaultStatus": "unknown", "product": "Extension Unit 12\" PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V01.01.01" } ] }, { "defaultStatus": "unknown", "product": "Extension Unit 15\" PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V01.01.01" } ] }, { "defaultStatus": "unknown", "product": "Extension Unit 19\" PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V01.01.01" } ] }, { "defaultStatus": "unknown", "product": "Extension Unit 22\" PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V01.01.01" } ] }, { "defaultStatus": "unknown", "product": "IE/AS-i Link PN IO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "IE/PB-Link (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M-800 family (incl. S615, MUM-800 and RM1224)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.03" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W-700 IEEE 802.11n family", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.1" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X-200 family (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X-200IRT family (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.4.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X-300 family (incl. X408 and SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X408 family", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X414", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.10.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM-400 family", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.1" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR-500 family", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CM 1542-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CM 1542SP-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.0.15" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1242-7 V2 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1.82" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-1 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1.82" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-7 LTE US", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1.82" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-8 IRC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1.82" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-8 IRC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1.82" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1542SP-1 IRC (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.0.15" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1543-1 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1543SP-1 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.0.15" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1604", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1616", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1626", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 343-1 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.1.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 343-1 Advanced (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 343-1 Lean (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.1.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 443-1 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 443-1 Advanced (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 443-1 OPC UA", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC DK-16xx PN IO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200AL IM 157-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V1.0.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200M (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN BA", "vendor": "Siemens", "versions": [ { "lessThan": "V4.0.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-3 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-4 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN BA", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN HS", "vendor": "Siemens", "versions": [ { "lessThan": "V4.0.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN ST BA", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 4AO U/I 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN: IO-Link Master", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200S (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC HMI Comfort Panels, HMI Multi Panels, HMI Mobile Panels (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV420 SR-B", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV420 SR-B Body", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV420 SR-P", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV420 SR-P Body", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV440 HR", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV440 SR", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV440 UR", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PN/PN Coupler (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF650R", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF680R", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF685R", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.2.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 Software Controller", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-200 SMART", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V3.X.14", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.0.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-410 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V8.2" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC TDC CP51M1", "vendor": "Siemens", "versions": [ { "lessThan": "V1.1.8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC TDC CPU555", "vendor": "Siemens", "versions": [ { "lessThan": "V1.1.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Teleservice Adapter IE Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Teleservice Adapter IE Basic", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Teleservice Adapter IE Standard", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinAC RTX 2010", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2010 SP3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinAC RTX F 2010", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2010 SP3" } ] }, { "defaultStatus": "unknown", "product": "SIMOCODE pro V PROFINET (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0.0" } ] }, { "defaultStatus": "unknown", "product": "SIMOTION", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.5 HF1" } ] }, { "defaultStatus": "unknown", "product": "SIMOTION D4xx V4.4 for SINAMICS SM150i-2 w. PROFINET (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4 HF26" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS DCM w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.4 SP1 HF5" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS DCP w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.2 HF1" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G110M w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP6 HF3" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP6 HF3" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G130 V4.7 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF27" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G130 V4.8 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G150 V4.7 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "V4.7: All versions \u003c V4.7 HF27" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G150 V4.8 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GH150 V4.7 w. PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP5 HF7" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GL150 V4.7 w. PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP2" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GM150 V4.7 w. PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF31" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S110 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4 SP3 HF5" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V4.7 w. PN (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF27" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V4.8 w. PN (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S150 V4.7 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF27" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S150 V4.8 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SL150 V4.7.0 w. PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF30" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SL150 V4.7.4 w. PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP2" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SL150 V4.7.5 w. PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP2" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SM120 V4.7 w. PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP2" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS V90 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.01" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK 828D V4.5 and prior", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.5 SP6 HF2" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK 828D V4.7", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP4 HF1" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK 840D sl V4.5 and prior", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.5 SP6 HF2" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK 840D sl V4.7", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP4 HF1" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN ST TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST BA", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIRIUS ACT 3SU1 interface module PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.1.0" } ] }, { "defaultStatus": "unknown", "product": "SIRIUS Motor Starter M200D PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIRIUS Soft Starter 3RW44 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SITOP PSU8600 PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.2.0" } ] }, { "defaultStatus": "unknown", "product": "SITOP UPS1600 PROFINET (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.2.0" } ] }, { "defaultStatus": "unknown", "product": "Softnet PROFINET IO for PC-based Windows systems", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V14 SP1" } ] } ], "descriptions": [ { "lang": "en", "value": "Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected." } ], "metrics": [ { "cvssV3_1": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400: Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-09-10T09:33:18.492Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "name": "1038463", "tags": [ "vdb-entry", "x_refsource_SECTRACK" ], "url": "http://www.securitytracker.com/id/1038463" }, { "name": "98369", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/98369" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-023-02" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-284673.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-284673.html" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-546832.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2017-2680", "datePublished": "2017-05-11T01:00:00", "dateReserved": "2016-12-01T00:00:00", "dateUpdated": "2024-09-10T09:33:18.492Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2017-2681
Vulnerability from cvelistv5
7.1 (High) - CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N
▼ | URL | Tags |
---|---|---|
http://www.securitytracker.com/id/1038463 | vdb-entry, x_refsource_SECTRACK | |
http://www.securityfocus.com/bid/98369 | vdb-entry, x_refsource_BID | |
https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf | x_refsource_CONFIRM | |
https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/html/ssa-293562.html |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2017-2681", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-07-23T20:22:19.045364Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-07-23T20:22:26.181Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-05T14:02:07.386Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "1038463", "tags": [ "vdb-entry", "x_refsource_SECTRACK", "x_transferred" ], "url": "http://www.securitytracker.com/id/1038463" }, { "name": "98369", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/98369" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.1 Patch04" } ] }, { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.2.1 Patch03" } ] }, { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4.0 Patch01" } ] }, { "defaultStatus": "unknown", "product": "IE/AS-i Link PN IO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "IE/PB-Link (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M-800 family (incl. S615, MUM-800 and RM1224)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.03" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W-700 IEEE 802.11n family", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.1" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X-200 family (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X-200IRT family (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.4.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X-300 family (incl. X408 and SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X408 family", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X414", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.10.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM-400 family", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.1" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR-500 family", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CM 1542-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CM 1542SP-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.0.15" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-1 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1.82" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-8 IRC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1.82" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1542SP-1 IRC (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.0.15" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1543-1 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1543SP-1 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.0.15" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1604", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1616", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 343-1 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.1.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 343-1 Advanced (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 343-1 Lean (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.1.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 443-1 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 443-1 Advanced (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 443-1 OPC UA", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC DK-16xx PN IO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200AL IM 157-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V1.0.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200M (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN BA", "vendor": "Siemens", "versions": [ { "lessThan": "V4.0.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-3 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-4 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN BA", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN HS", "vendor": "Siemens", "versions": [ { "lessThan": "V4.0.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN ST BA", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 4AO U/I 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN: IO-Link Master", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200S (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC HMI Comfort Panels, HMI Multi Panels, HMI Mobile Panels (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV420 SR-B", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV420 SR-B Body", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV420 SR-P", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV420 SR-P Body", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV440 HR", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV440 SR", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV440 UR", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PN/PN Coupler (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF650R", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF680R", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF685R", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.2.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 Software Controller", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-200 SMART", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V3.X.14", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.0.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-410 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V8.2" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC TDC CP51M1", "vendor": "Siemens", "versions": [ { "lessThan": "V1.1.8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC TDC CPU555", "vendor": "Siemens", "versions": [ { "lessThan": "V1.1.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Teleservice Adapter IE Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Teleservice Adapter IE Basic", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Teleservice Adapter IE Standard", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinAC RTX 2010", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2010 SP3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinAC RTX F 2010", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2010 SP3" } ] }, { "defaultStatus": "unknown", "product": "SIMOCODE pro V PROFINET (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0.0" } ] }, { "defaultStatus": "unknown", "product": "SIMOTION", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.5 HF1" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS DCM w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.4 SP1 HF5" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS DCP w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.2 HF1" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G110M w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP6 HF3" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP6 HF3" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G130 V4.7 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF27" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G130 V4.8 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G150 V4.7 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "V4.7: All versions \u003c V4.7 HF27" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G150 V4.8 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S110 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4 SP3 HF5" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V4.7 w. PN (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF27" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V4.8 w. PN (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S150 V4.7 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF27" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S150 V4.8 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS V90 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.01" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK 828D V4.5 and prior", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.5 SP6 HF2" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK 828D V4.7", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP4 HF1" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK 840D sl V4.5 and prior", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.5 SP6 HF2" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK 840D sl V4.7", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP4 HF1" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN ST TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST BA", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIRIUS ACT 3SU1 interface module PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.1.0" } ] }, { "defaultStatus": "unknown", "product": "SIRIUS Motor Starter M200D PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIRIUS Soft Starter 3RW44 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SITOP PSU8600 PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.2.0" } ] }, { "defaultStatus": "unknown", "product": "SITOP UPS1600 PROFINET (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.2.0" } ] }, { "defaultStatus": "unknown", "product": "Softnet PROFINET IO for PC-based Windows systems", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V14 SP1" } ] } ], "descriptions": [ { "lang": "en", "value": "Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected." } ], "metrics": [ { "cvssV3_1": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400: Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-09-10T09:33:20.658Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "name": "1038463", "tags": [ "vdb-entry", "x_refsource_SECTRACK" ], "url": "http://www.securitytracker.com/id/1038463" }, { "name": "98369", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/98369" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2017-2681", "datePublished": "2017-05-11T10:00:00", "dateReserved": "2016-12-01T00:00:00", "dateUpdated": "2024-09-10T09:33:20.658Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
var-201803-2159
Vulnerability from variot
A vulnerability has been identified in SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC CP 343-1 (incl. SIPLUS variants) (All versions), SIMATIC CP 343-1 Advanced (incl. SIPLUS variants) (All versions), SIMATIC CP 443-1 (All versions < V3.3), SIMATIC CP 443-1 (All versions < V3.3), SIMATIC CP 443-1 Advanced (All versions < V3.3), SIMATIC ET 200pro IM154-8 PN/DP CPU (All versions < V3.2.16), SIMATIC ET 200pro IM154-8F PN/DP CPU (All versions < V3.2.16), SIMATIC ET 200pro IM154-8FX PN/DP CPU (All versions < V3.2.16), SIMATIC ET 200S IM151-8 PN/DP CPU (All versions < V3.2.16), SIMATIC ET 200S IM151-8F PN/DP CPU (All versions < V3.2.16), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V1.7.0), SIMATIC S7-1500 Software Controller (All versions < V1.7.0), SIMATIC S7-300 CPU 314C-2 PN/DP (All versions < V3.3.16), SIMATIC S7-300 CPU 315-2 PN/DP (All versions < V3.2.16), SIMATIC S7-300 CPU 315F-2 PN/DP (All versions < V3.2.16), SIMATIC S7-300 CPU 315T-3 PN/DP (All versions < V3.2.16), SIMATIC S7-300 CPU 317-2 PN/DP (All versions < V3.2.16), SIMATIC S7-300 CPU 317F-2 PN/DP (All versions < V3.2.16), SIMATIC S7-300 CPU 317T-3 PN/DP (All versions < V3.2.16), SIMATIC S7-300 CPU 317TF-3 PN/DP (All versions < V3.2.16), SIMATIC S7-300 CPU 319-3 PN/DP (All versions < V3.2.16), SIMATIC S7-300 CPU 319F-3 PN/DP (All versions < V3.2.16), SIMATIC S7-400 CPU 412-2 PN V7 (All versions < V7.0.3), SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) (All versions < V6.0.9), SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants) (All versions < V6.0.7), SIMATIC S7-410 CPU family (incl. SIPLUS variants) (All versions < V8.1), SIMATIC WinAC RTX 2010 (All versions < V2010 SP3), SIMATIC WinAC RTX F 2010 (All versions < V2010 SP3), SINUMERIK 828D (All versions < V4.7 SP6 HF1), SIPLUS ET 200S IM151-8 PN/DP CPU (All versions < V3.2.16), SIPLUS ET 200S IM151-8F PN/DP CPU (All versions < V3.2.16), SIPLUS NET CP 443-1 (All versions < V3.3), SIPLUS NET CP 443-1 Advanced (All versions < V3.3), SIPLUS S7-300 CPU 314C-2 PN/DP (All versions < V3.3.16), SIPLUS S7-300 CPU 315-2 PN/DP (All versions < V3.2.16), SIPLUS S7-300 CPU 315F-2 PN/DP (All versions < V3.2.16), SIPLUS S7-300 CPU 317-2 PN/DP (All versions < V3.2.16), SIPLUS S7-300 CPU 317F-2 PN/DP (All versions < V3.2.16), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions < V7.0.3), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions < V7.0.3), Softnet PROFINET IO for PC-based Windows systems (All versions). Responding to a PROFINET DCP request with a specially crafted PROFINET DCP packet could cause a denial of service condition of the requesting system.
The security vulnerability could be exploited by an attacker located on the same Ethernet segment (OSI Layer 2) as the targeted device. A manual restart is required to recover the system. plural Siemens The product contains an input validation vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. Siemens SIMATIC CP 343-1 Advanced is an Ethernet communication module for supporting PROFINET, a new generation of automation bus standard based on Industrial Ethernet technology. SIMATIC S7-1500 is a programmable logic controller.
A denial of service vulnerability exists in several Siemens products. Siemens SIMATIC/SINUMERIK/PROFINET IO are prone to a denial-of-service vulnerability. Successful exploitation requires no user interaction or privileges and impacts the availability of core functionality of the affected device. At the time of advisory publication no public exploitation of this security vulnerability is known. Siemens provides mitigations to resolve the security issue. PROFIBUS interfaces are not affected. F; SINUMERIK 828D; SINUMERIK 840D sl; Softnet PROFINET IO for PC-based Windows systems
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201803-2159", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic s7-410", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "8.1" }, { "model": "simatic cp 343-1", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": null }, { "model": "simatic winac rtx 2010", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": null }, { "model": "simatic cp 443-1", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": null }, { "model": "simatic s7-300", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": null }, { "model": "simatic s7-400 pn\\/dp v7", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": null }, { "model": "sinumerik 828d", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": null }, { "model": "softnet pn-io linux", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": null }, { "model": "simatic s7-400 h v6", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": null }, { "model": "sinumerik 828d", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "simatic s7-400 pn\\/dp v6", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "6.0.7" }, { "model": "simatic s7-1500", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.7.0" }, { "model": "simatic cp 343-1", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic cp 443-1", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic s7-300", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic s7-400 pn/dp v6", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic s7-400 pn/dp v7", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic s7-400h v6", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic s7-410", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic winac rtx 2010", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "softnet profinet io", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "for pc-based windows systems firmware" }, { "model": "simatic cp advanced", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "343-1" }, { "model": "simatic cp standard", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "343-1" }, { "model": "simatic cp standard", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "443-1" }, { "model": "simatic s7-1500 software controller incl. f", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "1.7.0" }, { "model": "simatic s7-1500 incl. f", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "1.7.0" }, { "model": "simatic s7-300 incl. f and t", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic s7-400 h", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v6" }, { "model": "simatic s7-400 pn/dp incl. f", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v6\u003c6.0.7" }, { "model": "simatic s7-400 pn/dp incl. f", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v7" }, { "model": "simatic winac rtx incl. f", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "2010" }, { "model": "sinumerik 840d sl", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "softnet profinet io for pc-based windows systems", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": null, "scope": "eq", "trust": 0.4, "vendor": "simatic cp 343 1", "version": null }, { "model": null, "scope": "eq", "trust": 0.4, "vendor": "simatic cp 443 1", "version": null }, { "model": "softnet profinet io", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "sinumerik 840d sl", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "sinumerik 840d", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "sinumerik 828d", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic winac rtx", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "20100" }, { "model": "simatic s7-410", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "8" }, { "model": "simatic s7-400 pn/dp", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "7" }, { "model": "simatic s7-400 pn/dp", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "6" }, { "model": "simatic s7-400 h", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "v60" }, { "model": "simatic s7-300", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic s7-1500 software controller", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic s7-1500", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic cp standard", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "443-10" }, { "model": "simatic cp advanced", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "443-10" }, { "model": "simatic cp standard", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "343-10" }, { "model": "simatic cp advanced", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "343-10" }, { "model": "simatic s7-410", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "8.1" }, { "model": "simatic s7-400 pn/dp", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "6.0.7" }, { "model": "simatic s7-1500 software controller", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "1.7" }, { "model": "simatic s7-1500", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "1.7" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 410", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic winac rtx 2010", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinumerik 828d", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "softnet pn io linux", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 1500", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 300", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 400 h v6", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 400 pn dp v6", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 400 pn dp v7", "version": null } ], "sources": [ { "db": "IVD", "id": "e2e91df0-39ab-11e9-bef8-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2018-06025" }, { "db": "BID", "id": "103465" }, { "db": "JVNDB", "id": "JVNDB-2018-003479" }, { "db": "NVD", "id": "CVE-2018-4843" }, { "db": "CNNVD", "id": "CNNVD-201803-723" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_343-1_firmware:-:*:*:*:advanced:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_343-1:-:*:*:*:advanced:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_343-1_firmware:-:*:*:*:standard:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_343-1:-:*:*:*:standard:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_443-1_firmware:-:*:*:*:advanced:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_443-1:-:*:*:*:advanced:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_443-1_firmware:-:*:*:*:standard:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_443-1:-:*:*:*:standard:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1500_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.7.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1500:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-400_h_v6_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-400_h_v6:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-400_pn\\/dp_v6_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "6.0.7", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-400_pn\\/dp_v6:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-400_pn\\/dp_v7_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-400_pn\\/dp_v7:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-410_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.1", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-410:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_winac_rtx_2010_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_winac_rtx_2010:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:sinumerik_828d_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:sinumerik_828d:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:softnet_pn-io_linux_firmware:-:*:*:*:*:windows:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:softnet_pn-io_linux:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2018-4843" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens ProductCERT", "sources": [ { "db": "BID", "id": "103465" } ], "trust": 0.3 }, "cve": "CVE-2018-4843", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "COMPLETE", "baseScore": 6.1, "confidentialityImpact": "NONE", "exploitabilityScore": 6.5, "impactScore": 6.9, "integrityImpact": "NONE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Complete", "baseScore": 6.1, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2018-4843", "impactScore": null, "integrityImpact": "None", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "accessComplexity": "HIGH", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 4.6, "confidentialityImpact": "NONE", "exploitabilityScore": 3.2, "id": "CNVD-2018-06025", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:A/AC:H/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "accessComplexity": "HIGH", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "COMPLETE", "baseScore": 4.6, "confidentialityImpact": "NONE", "exploitabilityScore": 3.2, "id": "e2e91df0-39ab-11e9-bef8-000c29342cb1", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.2, "vectorString": "AV:A/AC:H/Au:N/C:N/I:N/A:C", "version": "2.9 [IVD]" }, { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "COMPLETE", "baseScore": 6.1, "confidentialityImpact": "NONE", "exploitabilityScore": 6.5, "id": "VHN-134874", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.1, "vectorString": "AV:A/AC:L/AU:N/C:N/I:N/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "exploitabilityScore": 2.8, "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "productcert@siemens.com", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "exploitabilityScore": 2.8, "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.5, "baseSeverity": "Medium", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2018-4843", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2018-4843", "trust": 1.8, "value": "MEDIUM" }, { "author": "productcert@siemens.com", "id": "CVE-2018-4843", "trust": 1.0, "value": "MEDIUM" }, { "author": "CNVD", "id": "CNVD-2018-06025", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-201803-723", "trust": 0.6, "value": "MEDIUM" }, { "author": "IVD", "id": "e2e91df0-39ab-11e9-bef8-000c29342cb1", "trust": 0.2, "value": "MEDIUM" }, { "author": "VULHUB", "id": "VHN-134874", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "IVD", "id": "e2e91df0-39ab-11e9-bef8-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2018-06025" }, { "db": "VULHUB", "id": "VHN-134874" }, { "db": "JVNDB", "id": "JVNDB-2018-003479" }, { "db": "NVD", "id": "CVE-2018-4843" }, { "db": "NVD", "id": "CVE-2018-4843" }, { "db": "CNNVD", "id": "CNNVD-201803-723" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions \u003c V7.0.3), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions \u003c V7.0.3), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions \u003c V7.0.3), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions \u003c V7.0.3), SIMATIC CP 343-1 (incl. SIPLUS variants) (All versions), SIMATIC CP 343-1 Advanced (incl. SIPLUS variants) (All versions), SIMATIC CP 443-1 (All versions \u003c V3.3), SIMATIC CP 443-1 (All versions \u003c V3.3), SIMATIC CP 443-1 Advanced (All versions \u003c V3.3), SIMATIC ET 200pro IM154-8 PN/DP CPU (All versions \u003c V3.2.16), SIMATIC ET 200pro IM154-8F PN/DP CPU (All versions \u003c V3.2.16), SIMATIC ET 200pro IM154-8FX PN/DP CPU (All versions \u003c V3.2.16), SIMATIC ET 200S IM151-8 PN/DP CPU (All versions \u003c V3.2.16), SIMATIC ET 200S IM151-8F PN/DP CPU (All versions \u003c V3.2.16), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V1.7.0), SIMATIC S7-1500 Software Controller (All versions \u003c V1.7.0), SIMATIC S7-300 CPU 314C-2 PN/DP (All versions \u003c V3.3.16), SIMATIC S7-300 CPU 315-2 PN/DP (All versions \u003c V3.2.16), SIMATIC S7-300 CPU 315F-2 PN/DP (All versions \u003c V3.2.16), SIMATIC S7-300 CPU 315T-3 PN/DP (All versions \u003c V3.2.16), SIMATIC S7-300 CPU 317-2 PN/DP (All versions \u003c V3.2.16), SIMATIC S7-300 CPU 317F-2 PN/DP (All versions \u003c V3.2.16), SIMATIC S7-300 CPU 317T-3 PN/DP (All versions \u003c V3.2.16), SIMATIC S7-300 CPU 317TF-3 PN/DP (All versions \u003c V3.2.16), SIMATIC S7-300 CPU 319-3 PN/DP (All versions \u003c V3.2.16), SIMATIC S7-300 CPU 319F-3 PN/DP (All versions \u003c V3.2.16), SIMATIC S7-400 CPU 412-2 PN V7 (All versions \u003c V7.0.3), SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) (All versions \u003c V6.0.9), SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants) (All versions \u003c V6.0.7), SIMATIC S7-410 CPU family (incl. SIPLUS variants) (All versions \u003c V8.1), SIMATIC WinAC RTX 2010 (All versions \u003c V2010 SP3), SIMATIC WinAC RTX F 2010 (All versions \u003c V2010 SP3), SINUMERIK 828D (All versions \u003c V4.7 SP6 HF1), SIPLUS ET 200S IM151-8 PN/DP CPU (All versions \u003c V3.2.16), SIPLUS ET 200S IM151-8F PN/DP CPU (All versions \u003c V3.2.16), SIPLUS NET CP 443-1 (All versions \u003c V3.3), SIPLUS NET CP 443-1 Advanced (All versions \u003c V3.3), SIPLUS S7-300 CPU 314C-2 PN/DP (All versions \u003c V3.3.16), SIPLUS S7-300 CPU 315-2 PN/DP (All versions \u003c V3.2.16), SIPLUS S7-300 CPU 315F-2 PN/DP (All versions \u003c V3.2.16), SIPLUS S7-300 CPU 317-2 PN/DP (All versions \u003c V3.2.16), SIPLUS S7-300 CPU 317F-2 PN/DP (All versions \u003c V3.2.16), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions \u003c V7.0.3), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions \u003c V7.0.3), Softnet PROFINET IO for PC-based Windows systems (All versions). Responding to a PROFINET DCP request with a specially crafted PROFINET DCP packet could cause a denial of service condition of the requesting system. \r\n\r\nThe security vulnerability could be exploited by an attacker located on the same Ethernet segment (OSI Layer 2) as the targeted device. A manual restart is required to recover the system. plural Siemens The product contains an input validation vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. Siemens SIMATIC CP 343-1 Advanced is an Ethernet communication module for supporting PROFINET, a new generation of automation bus standard based on Industrial Ethernet technology. SIMATIC S7-1500 is a programmable logic controller. \n\nA denial of service vulnerability exists in several Siemens products. Siemens SIMATIC/SINUMERIK/PROFINET IO are prone to a denial-of-service vulnerability. Successful exploitation requires no user interaction or privileges and impacts the availability of core functionality of the affected device. At the time of advisory publication no public exploitation of this security vulnerability is known. Siemens provides mitigations to resolve the security issue. PROFIBUS interfaces are not affected. F; SINUMERIK 828D; SINUMERIK 840D sl; Softnet PROFINET IO for PC-based Windows systems", "sources": [ { "db": "NVD", "id": "CVE-2018-4843" }, { "db": "JVNDB", "id": "JVNDB-2018-003479" }, { "db": "CNVD", "id": "CNVD-2018-06025" }, { "db": "BID", "id": "103465" }, { "db": "IVD", "id": "e2e91df0-39ab-11e9-bef8-000c29342cb1" }, { "db": "VULHUB", "id": "VHN-134874" } ], "trust": 2.7 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2018-4843", "trust": 3.6 }, { "db": "SIEMENS", "id": "SSA-592007", "trust": 2.0 }, { "db": "ICS CERT", "id": "ICSA-18-079-02", "trust": 1.7 }, { "db": "CNVD", "id": "CNVD-2018-06025", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-201803-723", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2018-003479", "trust": 0.8 }, { "db": "BID", "id": "103465", "trust": 0.4 }, { "db": "IVD", "id": "E2E91DF0-39AB-11E9-BEF8-000C29342CB1", "trust": 0.2 }, { "db": "SEEBUG", "id": "SSVID-98995", "trust": 0.1 }, { "db": "VULHUB", "id": "VHN-134874", "trust": 0.1 } ], "sources": [ { "db": "IVD", "id": "e2e91df0-39ab-11e9-bef8-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2018-06025" }, { "db": "VULHUB", "id": "VHN-134874" }, { "db": "BID", "id": "103465" }, { "db": "JVNDB", "id": "JVNDB-2018-003479" }, { "db": "NVD", "id": "CVE-2018-4843" }, { "db": "CNNVD", "id": "CNNVD-201803-723" } ] }, "id": "VAR-201803-2159", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "IVD", "id": "e2e91df0-39ab-11e9-bef8-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2018-06025" }, { "db": "VULHUB", "id": "VHN-134874" } ], "trust": 1.6409676735714287 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.8 } ], "sources": [ { "db": "IVD", "id": "e2e91df0-39ab-11e9-bef8-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2018-06025" } ] }, "last_update_date": "2023-12-18T13:33:56.565000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-592007", "trust": 0.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-592007.pdf" }, { "title": "Patch for Multiple Siemens Product Denial of Service Vulnerabilities (CNVD-2018-06025)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/122865" }, { "title": "Multiple Siemens Product security vulnerabilities", "trust": 0.6, "url": "http://123.124.177.30/web/xxk/bdxqbyid.tag?id=79323" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2018-06025" }, { "db": "JVNDB", "id": "JVNDB-2018-003479" }, { "db": "CNNVD", "id": "CNNVD-201803-723" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-20", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-134874" }, { "db": "JVNDB", "id": "JVNDB-2018-003479" }, { "db": "NVD", "id": "CVE-2018-4843" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.0, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-592007.pdf" }, { "trust": 1.7, "url": "https://ics-cert.us-cert.gov/advisories/icsa-18-079-02" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-4843" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2018-4843" }, { "trust": 0.3, "url": "http://www.siemens.com/" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2018-06025" }, { "db": "VULHUB", "id": "VHN-134874" }, { "db": "BID", "id": "103465" }, { "db": "JVNDB", "id": "JVNDB-2018-003479" }, { "db": "NVD", "id": "CVE-2018-4843" }, { "db": "CNNVD", "id": "CNNVD-201803-723" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "IVD", "id": "e2e91df0-39ab-11e9-bef8-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2018-06025" }, { "db": "VULHUB", "id": "VHN-134874" }, { "db": "BID", "id": "103465" }, { "db": "JVNDB", "id": "JVNDB-2018-003479" }, { "db": "NVD", "id": "CVE-2018-4843" }, { "db": "CNNVD", "id": "CNNVD-201803-723" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2018-03-22T00:00:00", "db": "IVD", "id": "e2e91df0-39ab-11e9-bef8-000c29342cb1" }, { "date": "2018-03-22T00:00:00", "db": "CNVD", "id": "CNVD-2018-06025" }, { "date": "2018-03-20T00:00:00", "db": "VULHUB", "id": "VHN-134874" }, { "date": "2018-03-20T00:00:00", "db": "BID", "id": "103465" }, { "date": "2018-05-24T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-003479" }, { "date": "2018-03-20T14:29:00.413000", "db": "NVD", "id": "CVE-2018-4843" }, { "date": "2018-03-21T00:00:00", "db": "CNNVD", "id": "CNNVD-201803-723" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-08-22T00:00:00", "db": "CNVD", "id": "CNVD-2018-06025" }, { "date": "2023-01-10T00:00:00", "db": "VULHUB", "id": "VHN-134874" }, { "date": "2018-03-20T00:00:00", "db": "BID", "id": "103465" }, { "date": "2018-07-04T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-003479" }, { "date": "2023-05-09T13:15:12.543000", "db": "NVD", "id": "CVE-2018-4843" }, { "date": "2023-05-10T00:00:00", "db": "CNNVD", "id": "CNNVD-201803-723" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-201803-723" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural Siemens Vulnerability related to input validation in products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-003479" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Input validation error", "sources": [ { "db": "IVD", "id": "e2e91df0-39ab-11e9-bef8-000c29342cb1" }, { "db": "BID", "id": "103465" }, { "db": "CNNVD", "id": "CNNVD-201803-723" } ], "trust": 1.1 } }