All the vulnerabilites related to Siemens - TIA Project-Server V16
cve-2022-35868
Vulnerability from cvelistv5
Published
2023-02-14 10:36
Modified
2024-08-13 07:50
Summary
A vulnerability has been identified in TIA Multiuser Server V14 (All versions), TIA Multiuser Server V15 (All versions < V15.1 Update 8), TIA Project-Server (All versions < V1.1), TIA Project-Server V16 (All versions), TIA Project-Server V17 (All versions < V17 Update 6). Affected applications contain an untrusted search path vulnerability that could allow an attacker to escalate privileges, when tricking a legitimate user to start the service from an attacker controlled path.
Impacted products
Vendor Product Version
Siemens TIA Multiuser Server V15 Version: All versions < V15.1 Update 8
Siemens TIA Project-Server Version: All versions < V1.1
Siemens TIA Project-Server V16 Version: 0   < *
Siemens TIA Project-Server V17 Version: All versions < V17 Update 6
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T09:44:22.098Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-640968.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TIA Multiuser Server V14",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TIA Multiuser Server V15",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1 Update 8"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TIA Project-Server",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TIA Project-Server V16",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TIA Project-Server V17",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V17 Update 6"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TIA Multiuser Server V14 (All versions), TIA Multiuser Server V15 (All versions \u003c V15.1 Update 8), TIA Project-Server (All versions \u003c V1.1), TIA Project-Server V16 (All versions), TIA Project-Server V17 (All versions \u003c V17 Update 6). Affected applications contain an untrusted search path vulnerability that could allow an attacker to escalate privileges, when tricking a legitimate user to start the service from an attacker controlled path."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.7,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-426",
              "description": "CWE-426: Untrusted Search Path",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-13T07:50:22.699Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-640968.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-640968.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-35868",
    "datePublished": "2023-02-14T10:36:08.964Z",
    "dateReserved": "2022-07-14T16:20:28.861Z",
    "dateUpdated": "2024-08-13T07:50:22.699Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}