Search criteria

4 vulnerabilities found for TRO600 by Hitachi Energy

CVE-2024-41156 (GCVE-0-2024-41156)

Vulnerability from cvelistv5 – Published: 2024-10-29 12:44 – Updated: 2025-01-09 17:15
VLAI?
Summary
Profile files from TRO600 series radios are extracted in plain-text and encrypted file formats. Profile files provide potential attackers valuable configuration information about the Tropos network. Profiles can only be exported by authenticated users with higher privilege of write access.
CWE
  • CWE-212 - Improper Removal of Sensitive Information Before Storage or Transfer
Assigner
References
Impacted products
Vendor Product Version
Hitachi Energy TRO600 Affected: 9.0.1.0 , ≤ 9.2.0.0 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-41156",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-29T13:50:37.518941Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-09T17:15:38.962Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "TRO600",
          "vendor": "Hitachi Energy",
          "versions": [
            {
              "lessThanOrEqual": "9.2.0.0",
              "status": "affected",
              "version": "9.0.1.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Profile files from TRO600 series radios are extracted in plain-text\nand encrypted file formats. Profile files provide potential attackers\nvaluable configuration information about the Tropos network. Profiles\ncan only be exported by authenticated users with higher privilege of write access.\n\n\n\u003cbr\u003e"
            }
          ],
          "value": "Profile files from TRO600 series radios are extracted in plain-text\nand encrypted file formats. Profile files provide potential attackers\nvaluable configuration information about the Tropos network. Profiles\ncan only be exported by authenticated users with higher privilege of write access."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-37",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-37 Retrieve Embedded Sensitive Data"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 2.7,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-212",
              "description": "CWE-212 Improper Removal of Sensitive Information Before Storage or Transfer",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-12-04T10:43:00.903Z",
        "orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
        "shortName": "Hitachi Energy"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000147\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=launch"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
    "assignerShortName": "Hitachi Energy",
    "cveId": "CVE-2024-41156",
    "datePublished": "2024-10-29T12:44:58.707Z",
    "dateReserved": "2024-07-16T16:02:30.296Z",
    "dateUpdated": "2025-01-09T17:15:38.962Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-41153 (GCVE-0-2024-41153)

Vulnerability from cvelistv5 – Published: 2024-10-29 12:30 – Updated: 2025-11-04 16:00
VLAI?
Summary
Command injection vulnerability in the Edge Computing UI for the TRO600 series radios that allows for the execution of arbitrary system commands. If exploited, an attacker with write access to the web UI can execute commands on the device with root privileges, far more extensive than what the write privilege intends.
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
Vendor Product Version
Hitachi Energy TRO600 Affected: 9.1.0.0 , ≤ 9.2.0.0 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:hitachi_energy:tro600:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "tro600",
            "vendor": "hitachi_energy",
            "versions": [
              {
                "lessThanOrEqual": "9.2.0.0",
                "status": "affected",
                "version": "9.1.0.0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-41153",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-29T13:54:05.290769Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-04T16:00:52.178Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "TRO600",
          "vendor": "Hitachi Energy",
          "versions": [
            {
              "lessThanOrEqual": "9.2.0.0",
              "status": "affected",
              "version": "9.1.0.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Command injection vulnerability in the Edge Computing UI for the\nTRO600 series radios that allows for the execution of arbitrary system commands. If exploited, an attacker with write access to the\nweb UI can execute commands on the device with root privileges,\nfar more extensive than what the write privilege intends.\n\n\u003cbr\u003e"
            }
          ],
          "value": "Command injection vulnerability in the Edge Computing UI for the\nTRO600 series radios that allows for the execution of arbitrary system commands. If exploited, an attacker with write access to the\nweb UI can execute commands on the device with root privileges,\nfar more extensive than what the write privilege intends."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-248",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-248 Command Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-24T08:38:07.234Z",
        "orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
        "shortName": "Hitachi Energy"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000147\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=launch"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
    "assignerShortName": "Hitachi Energy",
    "cveId": "CVE-2024-41153",
    "datePublished": "2024-10-29T12:30:31.402Z",
    "dateReserved": "2024-07-16T16:02:30.295Z",
    "dateUpdated": "2025-11-04T16:00:52.178Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2024-41156 (GCVE-0-2024-41156)

Vulnerability from nvd – Published: 2024-10-29 12:44 – Updated: 2025-01-09 17:15
VLAI?
Summary
Profile files from TRO600 series radios are extracted in plain-text and encrypted file formats. Profile files provide potential attackers valuable configuration information about the Tropos network. Profiles can only be exported by authenticated users with higher privilege of write access.
CWE
  • CWE-212 - Improper Removal of Sensitive Information Before Storage or Transfer
Assigner
References
Impacted products
Vendor Product Version
Hitachi Energy TRO600 Affected: 9.0.1.0 , ≤ 9.2.0.0 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-41156",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-29T13:50:37.518941Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-09T17:15:38.962Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "TRO600",
          "vendor": "Hitachi Energy",
          "versions": [
            {
              "lessThanOrEqual": "9.2.0.0",
              "status": "affected",
              "version": "9.0.1.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Profile files from TRO600 series radios are extracted in plain-text\nand encrypted file formats. Profile files provide potential attackers\nvaluable configuration information about the Tropos network. Profiles\ncan only be exported by authenticated users with higher privilege of write access.\n\n\n\u003cbr\u003e"
            }
          ],
          "value": "Profile files from TRO600 series radios are extracted in plain-text\nand encrypted file formats. Profile files provide potential attackers\nvaluable configuration information about the Tropos network. Profiles\ncan only be exported by authenticated users with higher privilege of write access."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-37",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-37 Retrieve Embedded Sensitive Data"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 2.7,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-212",
              "description": "CWE-212 Improper Removal of Sensitive Information Before Storage or Transfer",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-12-04T10:43:00.903Z",
        "orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
        "shortName": "Hitachi Energy"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000147\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=launch"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
    "assignerShortName": "Hitachi Energy",
    "cveId": "CVE-2024-41156",
    "datePublished": "2024-10-29T12:44:58.707Z",
    "dateReserved": "2024-07-16T16:02:30.296Z",
    "dateUpdated": "2025-01-09T17:15:38.962Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-41153 (GCVE-0-2024-41153)

Vulnerability from nvd – Published: 2024-10-29 12:30 – Updated: 2025-11-04 16:00
VLAI?
Summary
Command injection vulnerability in the Edge Computing UI for the TRO600 series radios that allows for the execution of arbitrary system commands. If exploited, an attacker with write access to the web UI can execute commands on the device with root privileges, far more extensive than what the write privilege intends.
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
Vendor Product Version
Hitachi Energy TRO600 Affected: 9.1.0.0 , ≤ 9.2.0.0 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:hitachi_energy:tro600:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "tro600",
            "vendor": "hitachi_energy",
            "versions": [
              {
                "lessThanOrEqual": "9.2.0.0",
                "status": "affected",
                "version": "9.1.0.0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-41153",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-29T13:54:05.290769Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-04T16:00:52.178Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "TRO600",
          "vendor": "Hitachi Energy",
          "versions": [
            {
              "lessThanOrEqual": "9.2.0.0",
              "status": "affected",
              "version": "9.1.0.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Command injection vulnerability in the Edge Computing UI for the\nTRO600 series radios that allows for the execution of arbitrary system commands. If exploited, an attacker with write access to the\nweb UI can execute commands on the device with root privileges,\nfar more extensive than what the write privilege intends.\n\n\u003cbr\u003e"
            }
          ],
          "value": "Command injection vulnerability in the Edge Computing UI for the\nTRO600 series radios that allows for the execution of arbitrary system commands. If exploited, an attacker with write access to the\nweb UI can execute commands on the device with root privileges,\nfar more extensive than what the write privilege intends."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-248",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-248 Command Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-24T08:38:07.234Z",
        "orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
        "shortName": "Hitachi Energy"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000147\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=launch"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
    "assignerShortName": "Hitachi Energy",
    "cveId": "CVE-2024-41153",
    "datePublished": "2024-10-29T12:30:31.402Z",
    "dateReserved": "2024-07-16T16:02:30.295Z",
    "dateUpdated": "2025-11-04T16:00:52.178Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}