Search criteria

9 vulnerabilities found for TX9 by Tenda

VAR-202404-0214

Vulnerability from variot - Updated: 2024-05-25 01:42

A vulnerability classified as critical was found in Tenda TX9 22.03.02.10. This vulnerability affects the function sub_42D4DC of the file /goform/SetSysTimeCfg. The manipulation of the argument time leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261856. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda TX9 is a dual-band Wi-Fi 6 router from China's Tenda company. No detailed vulnerability details are currently provided

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202404-0214",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "tx9",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "22.03.02.10"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-23318"
      }
    ]
  },
  "cve": "CVE-2024-4113",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "cna@vuldb.com",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.0,
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "HIGH",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.0,
            "id": "CNVD-2024-23318",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "cna@vuldb.com",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "cna@vuldb.com",
            "id": "CVE-2024-4113",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2024-23318",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-23318"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-4113"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability classified as critical was found in Tenda TX9 22.03.02.10. This vulnerability affects the function sub_42D4DC of the file /goform/SetSysTimeCfg. The manipulation of the argument time leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261856. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda TX9 is a dual-band Wi-Fi 6 router from China\u0027s Tenda company. No detailed vulnerability details are currently provided",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-4113"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-23318"
      }
    ],
    "trust": 1.44
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2024-4113",
        "trust": 1.6
      },
      {
        "db": "VULDB",
        "id": "261856",
        "trust": 1.0
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-23318",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-23318"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-4113"
      }
    ]
  },
  "id": "VAR-202404-0214",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-23318"
      }
    ],
    "trust": 0.06
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-23318"
      }
    ]
  },
  "last_update_date": "2024-05-25T01:42:29.301000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Tenda TX9 has an unspecified vulnerability (CNVD-2024-23318)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchinfo/show/546941"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-23318"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-121",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-4113"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.0,
        "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/tx9/fromsetsystime.md"
      },
      {
        "trust": 1.0,
        "url": "https://vuldb.com/?ctiid.261856"
      },
      {
        "trust": 1.0,
        "url": "https://vuldb.com/?id.261856"
      },
      {
        "trust": 1.0,
        "url": "https://vuldb.com/?submit.317217"
      },
      {
        "trust": 0.6,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2024-4113"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-23318"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-4113"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-23318"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-4113"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-05-17T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-23318"
      },
      {
        "date": "2024-04-24T15:15:48.890000",
        "db": "NVD",
        "id": "CVE-2024-4113"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-05-20T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-23318"
      },
      {
        "date": "2024-05-17T02:40:15.830000",
        "db": "NVD",
        "id": "CVE-2024-4113"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda TX9 has an unspecified vulnerability (CNVD-2024-23318)",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-23318"
      }
    ],
    "trust": 0.6
  }
}

CVE-2024-4114 (GCVE-0-2024-4114)

Vulnerability from cvelistv5 – Published: 2024-04-24 15:00 – Updated: 2024-08-01 20:33
VLAI?
Title
Tenda TX9 PowerSaveSet sub_42C014 stack-based overflow
Summary
A vulnerability, which was classified as critical, has been found in Tenda TX9 22.03.02.10. This issue affects the function sub_42C014 of the file /goform/PowerSaveSet. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261857 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Tenda TX9 Affected: 22.03.02.10
Create a notification for this product.
Credits
wxhwxhwxh_tutu (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:tx9_pro_firmware:22.03.02.10:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "tx9_pro_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "22.03.02.10"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4114",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-03T17:12:21.959356Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-03T21:02:13.048Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:33:52.409Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-261857 | Tenda TX9 PowerSaveSet sub_42C014 stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.261857"
          },
          {
            "name": "VDB-261857 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.261857"
          },
          {
            "name": "Submit #317218 | Tenda TX9 Pro V22.03.02.10 buffer overflow",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.317218"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/TX9/setSmartPowerManagement.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "TX9",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "22.03.02.10"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "wxhwxhwxh_tutu (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability, which was classified as critical, has been found in Tenda TX9 22.03.02.10. This issue affects the function sub_42C014 of the file /goform/PowerSaveSet. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261857 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in Tenda TX9 22.03.02.10 entdeckt. Sie wurde als kritisch eingestuft. Dies betrifft die Funktion sub_42C014 der Datei /goform/PowerSaveSet. Mit der Manipulation des Arguments time mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-24T15:00:08.450Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-261857 | Tenda TX9 PowerSaveSet sub_42C014 stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.261857"
        },
        {
          "name": "VDB-261857 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.261857"
        },
        {
          "name": "Submit #317218 | Tenda TX9 Pro V22.03.02.10 buffer overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.317218"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/TX9/setSmartPowerManagement.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-04-24T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-04-24T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-04-24T10:24:43.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda TX9 PowerSaveSet sub_42C014 stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-4114",
    "datePublished": "2024-04-24T15:00:08.450Z",
    "dateReserved": "2024-04-24T08:18:53.835Z",
    "dateUpdated": "2024-08-01T20:33:52.409Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-4113 (GCVE-0-2024-4113)

Vulnerability from cvelistv5 – Published: 2024-04-24 15:00 – Updated: 2024-08-01 20:33
VLAI?
Title
Tenda TX9 SetSysTimeCfg sub_42D4DC stack-based overflow
Summary
A vulnerability classified as critical was found in Tenda TX9 22.03.02.10. This vulnerability affects the function sub_42D4DC of the file /goform/SetSysTimeCfg. The manipulation of the argument time leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261856. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Tenda TX9 Affected: 22.03.02.10
Create a notification for this product.
Credits
wxhwxhwxh_tutu (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:tx9_pro_firmware:22.03.02.10:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "tx9_pro_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "22.03.02.10"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4113",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-03T17:15:47.958452Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-03T21:02:35.914Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:33:52.536Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-261856 | Tenda TX9 SetSysTimeCfg sub_42D4DC stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.261856"
          },
          {
            "name": "VDB-261856 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.261856"
          },
          {
            "name": "Submit #317217 | Tenda TX9 Pro V22.03.02.10 buffer overflow",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.317217"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/TX9/fromSetSysTime.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "TX9",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "22.03.02.10"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "wxhwxhwxh_tutu (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability classified as critical was found in Tenda TX9 22.03.02.10. This vulnerability affects the function sub_42D4DC of the file /goform/SetSysTimeCfg. The manipulation of the argument time leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261856. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "In Tenda TX9 22.03.02.10 wurde eine Schwachstelle entdeckt. Sie wurde als kritisch eingestuft. Das betrifft die Funktion sub_42D4DC der Datei /goform/SetSysTimeCfg. Dank Manipulation des Arguments time mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-24T15:00:06.772Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-261856 | Tenda TX9 SetSysTimeCfg sub_42D4DC stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.261856"
        },
        {
          "name": "VDB-261856 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.261856"
        },
        {
          "name": "Submit #317217 | Tenda TX9 Pro V22.03.02.10 buffer overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.317217"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/TX9/fromSetSysTime.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-04-24T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-04-24T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-04-24T10:24:41.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda TX9 SetSysTimeCfg sub_42D4DC stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-4113",
    "datePublished": "2024-04-24T15:00:06.772Z",
    "dateReserved": "2024-04-24T08:18:51.119Z",
    "dateUpdated": "2024-08-01T20:33:52.536Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-4112 (GCVE-0-2024-4112)

Vulnerability from cvelistv5 – Published: 2024-04-24 14:31 – Updated: 2024-08-21 21:12
VLAI?
Title
Tenda TX9 SetVirtualServerCfg sub_42CB94 stack-based overflow
Summary
A vulnerability classified as critical has been found in Tenda TX9 22.03.02.10. This affects the function sub_42CB94 of the file /goform/SetVirtualServerCfg. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261855. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Tenda TX9 Affected: 22.03.02.10
Create a notification for this product.
Credits
yhryhryhr_tu (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:33:52.383Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-261855 | Tenda TX9 SetVirtualServerCfg sub_42CB94 stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.261855"
          },
          {
            "name": "VDB-261855 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.261855"
          },
          {
            "name": "Submit #317206 | Tenda TX9 Pro V22.03.02.10 buffer overflow",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.317206"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/TX9/formSetVirtualSer.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:tx9_pro_firmware:22.03.02.10:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "tx9_pro_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "22.03.02.10"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4112",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-17T13:20:41.483117Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-21T21:12:18.068Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "TX9",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "22.03.02.10"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "yhryhryhr_tu (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability classified as critical has been found in Tenda TX9 22.03.02.10. This affects the function sub_42CB94 of the file /goform/SetVirtualServerCfg. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261855. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Es wurde eine Schwachstelle in Tenda TX9 22.03.02.10 entdeckt. Sie wurde als kritisch eingestuft. Es betrifft die Funktion sub_42CB94 der Datei /goform/SetVirtualServerCfg. Dank der Manipulation des Arguments list mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-24T14:31:04.752Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-261855 | Tenda TX9 SetVirtualServerCfg sub_42CB94 stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.261855"
        },
        {
          "name": "VDB-261855 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.261855"
        },
        {
          "name": "Submit #317206 | Tenda TX9 Pro V22.03.02.10 buffer overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.317206"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/TX9/formSetVirtualSer.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-04-24T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-04-24T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-04-24T10:24:40.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda TX9 SetVirtualServerCfg sub_42CB94 stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-4112",
    "datePublished": "2024-04-24T14:31:04.752Z",
    "dateReserved": "2024-04-24T08:18:48.406Z",
    "dateUpdated": "2024-08-21T21:12:18.068Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-4111 (GCVE-0-2024-4111)

Vulnerability from cvelistv5 – Published: 2024-04-24 14:00 – Updated: 2024-08-01 20:33
VLAI?
Title
Tenda TX9 SetLEDCfg sub_42BD7C stack-based overflow
Summary
A vulnerability was found in Tenda TX9 22.03.02.10. It has been rated as critical. Affected by this issue is the function sub_42BD7C of the file /goform/SetLEDCfg. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261854 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Tenda TX9 Affected: 22.03.02.10
Create a notification for this product.
Credits
yhryhryhr_tu (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4111",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-29T18:30:42.968664Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:53:46.885Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:33:52.366Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-261854 | Tenda TX9 SetLEDCfg sub_42BD7C stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.261854"
          },
          {
            "name": "VDB-261854 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.261854"
          },
          {
            "name": "Submit #317205 | Tenda TX9 Pro V22.03.02.10 buffer overflow",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.317205"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/TX9/SetLEDCfg.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "TX9",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "22.03.02.10"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "yhryhryhr_tu (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda TX9 22.03.02.10. It has been rated as critical. Affected by this issue is the function sub_42BD7C of the file /goform/SetLEDCfg. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261854 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Eine kritische Schwachstelle wurde in Tenda TX9 22.03.02.10 ausgemacht. Hierbei geht es um die Funktion sub_42BD7C der Datei /goform/SetLEDCfg. Durch Beeinflussen des Arguments time mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-24T14:00:05.565Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-261854 | Tenda TX9 SetLEDCfg sub_42BD7C stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.261854"
        },
        {
          "name": "VDB-261854 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.261854"
        },
        {
          "name": "Submit #317205 | Tenda TX9 Pro V22.03.02.10 buffer overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.317205"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/TX9/SetLEDCfg.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-04-24T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-04-24T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-04-24T10:24:37.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda TX9 SetLEDCfg sub_42BD7C stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-4111",
    "datePublished": "2024-04-24T14:00:05.565Z",
    "dateReserved": "2024-04-24T08:18:46.209Z",
    "dateUpdated": "2024-08-01T20:33:52.366Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-4114 (GCVE-0-2024-4114)

Vulnerability from nvd – Published: 2024-04-24 15:00 – Updated: 2024-08-01 20:33
VLAI?
Title
Tenda TX9 PowerSaveSet sub_42C014 stack-based overflow
Summary
A vulnerability, which was classified as critical, has been found in Tenda TX9 22.03.02.10. This issue affects the function sub_42C014 of the file /goform/PowerSaveSet. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261857 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Tenda TX9 Affected: 22.03.02.10
Create a notification for this product.
Credits
wxhwxhwxh_tutu (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:tx9_pro_firmware:22.03.02.10:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "tx9_pro_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "22.03.02.10"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4114",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-03T17:12:21.959356Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-03T21:02:13.048Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:33:52.409Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-261857 | Tenda TX9 PowerSaveSet sub_42C014 stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.261857"
          },
          {
            "name": "VDB-261857 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.261857"
          },
          {
            "name": "Submit #317218 | Tenda TX9 Pro V22.03.02.10 buffer overflow",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.317218"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/TX9/setSmartPowerManagement.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "TX9",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "22.03.02.10"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "wxhwxhwxh_tutu (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability, which was classified as critical, has been found in Tenda TX9 22.03.02.10. This issue affects the function sub_42C014 of the file /goform/PowerSaveSet. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261857 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in Tenda TX9 22.03.02.10 entdeckt. Sie wurde als kritisch eingestuft. Dies betrifft die Funktion sub_42C014 der Datei /goform/PowerSaveSet. Mit der Manipulation des Arguments time mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-24T15:00:08.450Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-261857 | Tenda TX9 PowerSaveSet sub_42C014 stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.261857"
        },
        {
          "name": "VDB-261857 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.261857"
        },
        {
          "name": "Submit #317218 | Tenda TX9 Pro V22.03.02.10 buffer overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.317218"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/TX9/setSmartPowerManagement.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-04-24T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-04-24T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-04-24T10:24:43.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda TX9 PowerSaveSet sub_42C014 stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-4114",
    "datePublished": "2024-04-24T15:00:08.450Z",
    "dateReserved": "2024-04-24T08:18:53.835Z",
    "dateUpdated": "2024-08-01T20:33:52.409Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-4113 (GCVE-0-2024-4113)

Vulnerability from nvd – Published: 2024-04-24 15:00 – Updated: 2024-08-01 20:33
VLAI?
Title
Tenda TX9 SetSysTimeCfg sub_42D4DC stack-based overflow
Summary
A vulnerability classified as critical was found in Tenda TX9 22.03.02.10. This vulnerability affects the function sub_42D4DC of the file /goform/SetSysTimeCfg. The manipulation of the argument time leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261856. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Tenda TX9 Affected: 22.03.02.10
Create a notification for this product.
Credits
wxhwxhwxh_tutu (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:tx9_pro_firmware:22.03.02.10:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "tx9_pro_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "22.03.02.10"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4113",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-03T17:15:47.958452Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-03T21:02:35.914Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:33:52.536Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-261856 | Tenda TX9 SetSysTimeCfg sub_42D4DC stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.261856"
          },
          {
            "name": "VDB-261856 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.261856"
          },
          {
            "name": "Submit #317217 | Tenda TX9 Pro V22.03.02.10 buffer overflow",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.317217"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/TX9/fromSetSysTime.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "TX9",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "22.03.02.10"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "wxhwxhwxh_tutu (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability classified as critical was found in Tenda TX9 22.03.02.10. This vulnerability affects the function sub_42D4DC of the file /goform/SetSysTimeCfg. The manipulation of the argument time leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261856. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "In Tenda TX9 22.03.02.10 wurde eine Schwachstelle entdeckt. Sie wurde als kritisch eingestuft. Das betrifft die Funktion sub_42D4DC der Datei /goform/SetSysTimeCfg. Dank Manipulation des Arguments time mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-24T15:00:06.772Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-261856 | Tenda TX9 SetSysTimeCfg sub_42D4DC stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.261856"
        },
        {
          "name": "VDB-261856 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.261856"
        },
        {
          "name": "Submit #317217 | Tenda TX9 Pro V22.03.02.10 buffer overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.317217"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/TX9/fromSetSysTime.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-04-24T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-04-24T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-04-24T10:24:41.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda TX9 SetSysTimeCfg sub_42D4DC stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-4113",
    "datePublished": "2024-04-24T15:00:06.772Z",
    "dateReserved": "2024-04-24T08:18:51.119Z",
    "dateUpdated": "2024-08-01T20:33:52.536Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-4112 (GCVE-0-2024-4112)

Vulnerability from nvd – Published: 2024-04-24 14:31 – Updated: 2024-08-21 21:12
VLAI?
Title
Tenda TX9 SetVirtualServerCfg sub_42CB94 stack-based overflow
Summary
A vulnerability classified as critical has been found in Tenda TX9 22.03.02.10. This affects the function sub_42CB94 of the file /goform/SetVirtualServerCfg. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261855. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Tenda TX9 Affected: 22.03.02.10
Create a notification for this product.
Credits
yhryhryhr_tu (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:33:52.383Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-261855 | Tenda TX9 SetVirtualServerCfg sub_42CB94 stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.261855"
          },
          {
            "name": "VDB-261855 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.261855"
          },
          {
            "name": "Submit #317206 | Tenda TX9 Pro V22.03.02.10 buffer overflow",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.317206"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/TX9/formSetVirtualSer.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:tx9_pro_firmware:22.03.02.10:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "tx9_pro_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "22.03.02.10"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4112",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-17T13:20:41.483117Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-21T21:12:18.068Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "TX9",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "22.03.02.10"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "yhryhryhr_tu (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability classified as critical has been found in Tenda TX9 22.03.02.10. This affects the function sub_42CB94 of the file /goform/SetVirtualServerCfg. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261855. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Es wurde eine Schwachstelle in Tenda TX9 22.03.02.10 entdeckt. Sie wurde als kritisch eingestuft. Es betrifft die Funktion sub_42CB94 der Datei /goform/SetVirtualServerCfg. Dank der Manipulation des Arguments list mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-24T14:31:04.752Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-261855 | Tenda TX9 SetVirtualServerCfg sub_42CB94 stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.261855"
        },
        {
          "name": "VDB-261855 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.261855"
        },
        {
          "name": "Submit #317206 | Tenda TX9 Pro V22.03.02.10 buffer overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.317206"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/TX9/formSetVirtualSer.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-04-24T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-04-24T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-04-24T10:24:40.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda TX9 SetVirtualServerCfg sub_42CB94 stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-4112",
    "datePublished": "2024-04-24T14:31:04.752Z",
    "dateReserved": "2024-04-24T08:18:48.406Z",
    "dateUpdated": "2024-08-21T21:12:18.068Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-4111 (GCVE-0-2024-4111)

Vulnerability from nvd – Published: 2024-04-24 14:00 – Updated: 2024-08-01 20:33
VLAI?
Title
Tenda TX9 SetLEDCfg sub_42BD7C stack-based overflow
Summary
A vulnerability was found in Tenda TX9 22.03.02.10. It has been rated as critical. Affected by this issue is the function sub_42BD7C of the file /goform/SetLEDCfg. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261854 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Tenda TX9 Affected: 22.03.02.10
Create a notification for this product.
Credits
yhryhryhr_tu (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4111",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-29T18:30:42.968664Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:53:46.885Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:33:52.366Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-261854 | Tenda TX9 SetLEDCfg sub_42BD7C stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.261854"
          },
          {
            "name": "VDB-261854 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.261854"
          },
          {
            "name": "Submit #317205 | Tenda TX9 Pro V22.03.02.10 buffer overflow",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.317205"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/TX9/SetLEDCfg.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "TX9",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "22.03.02.10"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "yhryhryhr_tu (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda TX9 22.03.02.10. It has been rated as critical. Affected by this issue is the function sub_42BD7C of the file /goform/SetLEDCfg. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261854 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Eine kritische Schwachstelle wurde in Tenda TX9 22.03.02.10 ausgemacht. Hierbei geht es um die Funktion sub_42BD7C der Datei /goform/SetLEDCfg. Durch Beeinflussen des Arguments time mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-24T14:00:05.565Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-261854 | Tenda TX9 SetLEDCfg sub_42BD7C stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.261854"
        },
        {
          "name": "VDB-261854 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.261854"
        },
        {
          "name": "Submit #317205 | Tenda TX9 Pro V22.03.02.10 buffer overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.317205"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/TX9/SetLEDCfg.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-04-24T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-04-24T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-04-24T10:24:37.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda TX9 SetLEDCfg sub_42BD7C stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-4111",
    "datePublished": "2024-04-24T14:00:05.565Z",
    "dateReserved": "2024-04-24T08:18:46.209Z",
    "dateUpdated": "2024-08-01T20:33:52.366Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}