Summary
A vulnerability has been identified in Teamcenter V12.4 (All versions < V12.4.0.13), Teamcenter V13.0 (All versions < V13.0.0.9), Teamcenter V13.1 (All versions < V13.1.0.9), Teamcenter V13.2 (All versions < V13.2.0.9), Teamcenter V13.3 (All versions < V13.3.0.3), Teamcenter V14.0 (All versions < V14.0.0.2). Java EE Server Manager HTML Adaptor in Teamcenter consists of default hardcoded credentials. Access to the application allows a user to perform a series of actions that could potentially lead to remote code execution with elevated permissions.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T07:26:00.834Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-220589.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Teamcenter V12.4",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V12.4.0.13"
            }
          ]
        },
        {
          "product": "Teamcenter V13.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.0.0.9"
            }
          ]
        },
        {
          "product": "Teamcenter V13.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.1.0.9"
            }
          ]
        },
        {
          "product": "Teamcenter V13.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.2.0.9"
            }
          ]
        },
        {
          "product": "Teamcenter V13.3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.3.0.3"
            }
          ]
        },
        {
          "product": "Teamcenter V14.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.0.0.2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Teamcenter V12.4 (All versions \u003c V12.4.0.13), Teamcenter V13.0 (All versions \u003c V13.0.0.9), Teamcenter V13.1 (All versions \u003c V13.1.0.9), Teamcenter V13.2 (All versions \u003c V13.2.0.9), Teamcenter V13.3 (All versions \u003c V13.3.0.3), Teamcenter V14.0 (All versions \u003c V14.0.0.2). Java EE Server Manager HTML Adaptor in Teamcenter consists of default hardcoded credentials. Access to the application allows a user to perform a series of actions that could potentially lead to remote code execution with elevated permissions."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-798",
              "description": "CWE-798: Use of Hard-coded Credentials",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-10T11:17:45",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-220589.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-31619",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Teamcenter V12.4",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V12.4.0.13"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Teamcenter V13.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V13.0.0.9"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Teamcenter V13.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V13.1.0.9"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Teamcenter V13.2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V13.2.0.9"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Teamcenter V13.3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V13.3.0.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Teamcenter V14.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V14.0.0.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Teamcenter V12.4 (All versions \u003c V12.4.0.13), Teamcenter V13.0 (All versions \u003c V13.0.0.9), Teamcenter V13.1 (All versions \u003c V13.1.0.9), Teamcenter V13.2 (All versions \u003c V13.2.0.9), Teamcenter V13.3 (All versions \u003c V13.3.0.3), Teamcenter V14.0 (All versions \u003c V14.0.0.2). Java EE Server Manager HTML Adaptor in Teamcenter consists of default hardcoded credentials. Access to the application allows a user to perform a series of actions that could potentially lead to remote code execution with elevated permissions."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-798: Use of Hard-coded Credentials"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-220589.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-220589.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-31619",
    "datePublished": "2022-06-14T09:21:57",
    "dateReserved": "2022-05-25T00:00:00",
    "dateUpdated": "2024-08-03T07:26:00.834Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-34660
Vulnerability from cvelistv5
Published
2022-08-10 11:18
Modified
2024-08-03 09:15
Severity ?
Summary
A vulnerability has been identified in Teamcenter V12.4 (All versions < V12.4.0.15), Teamcenter V13.0 (All versions < V13.0.0.10), Teamcenter V13.1 (All versions < V13.1.0.10), Teamcenter V13.2 (All versions < V13.2.0.9), Teamcenter V13.3 (All versions < V13.3.0.5), Teamcenter V14.0 (All versions < V14.0.0.2). File Server Cache service in Teamcenter consist of a functionality that is vulnerable to command injection. This could potentially allow an attacker to perform remote code execution.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T09:15:15.868Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-759952.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Teamcenter V12.4",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V12.4.0.15"
            }
          ]
        },
        {
          "product": "Teamcenter V13.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.0.0.10"
            }
          ]
        },
        {
          "product": "Teamcenter V13.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.1.0.10"
            }
          ]
        },
        {
          "product": "Teamcenter V13.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.2.0.9"
            }
          ]
        },
        {
          "product": "Teamcenter V13.3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.3.0.5"
            }
          ]
        },
        {
          "product": "Teamcenter V14.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.0.0.2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Teamcenter V12.4 (All versions \u003c V12.4.0.15), Teamcenter V13.0 (All versions \u003c V13.0.0.10), Teamcenter V13.1 (All versions \u003c V13.1.0.10), Teamcenter V13.2 (All versions \u003c V13.2.0.9), Teamcenter V13.3 (All versions \u003c V13.3.0.5), Teamcenter V14.0 (All versions \u003c V14.0.0.2). File Server Cache service in Teamcenter consist of a functionality that is vulnerable to command injection. This could potentially allow an attacker to perform remote code execution."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-10T11:18:01",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-759952.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-34660",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Teamcenter V12.4",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V12.4.0.15"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Teamcenter V13.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V13.0.0.10"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Teamcenter V13.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V13.1.0.10"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Teamcenter V13.2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V13.2.0.9"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Teamcenter V13.3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V13.3.0.5"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Teamcenter V14.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V14.0.0.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Teamcenter V12.4 (All versions \u003c V12.4.0.15), Teamcenter V13.0 (All versions \u003c V13.0.0.10), Teamcenter V13.1 (All versions \u003c V13.1.0.10), Teamcenter V13.2 (All versions \u003c V13.2.0.9), Teamcenter V13.3 (All versions \u003c V13.3.0.5), Teamcenter V14.0 (All versions \u003c V14.0.0.2). File Server Cache service in Teamcenter consist of a functionality that is vulnerable to command injection. This could potentially allow an attacker to perform remote code execution."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-759952.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-759952.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-34660",
    "datePublished": "2022-08-10T11:18:01",
    "dateReserved": "2022-06-27T00:00:00",
    "dateUpdated": "2024-08-03T09:15:15.868Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-24290
Vulnerability from cvelistv5
Published
2022-05-10 09:46
Modified
2024-08-03 04:07
Severity ?
Summary
A vulnerability has been identified in Teamcenter V12.4 (All versions < V12.4.0.13), Teamcenter V13.0 (All versions < V13.0.0.9), Teamcenter V13.1 (All versions), Teamcenter V13.2 (All versions < V13.2.0.8), Teamcenter V13.3 (All versions < V13.3.0.3), Teamcenter V14.0 (All versions < V14.0.0.2). The tcserver.exe binary in affected applications is vulnerable to a stack overflow condition during the parsing of user input that may lead the binary to crash.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:07:02.458Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-789162.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Teamcenter V12.4",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V12.4.0.13"
            }
          ]
        },
        {
          "product": "Teamcenter V13.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.0.0.9"
            }
          ]
        },
        {
          "product": "Teamcenter V13.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "Teamcenter V13.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.2.0.8"
            }
          ]
        },
        {
          "product": "Teamcenter V13.3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.3.0.3"
            }
          ]
        },
        {
          "product": "Teamcenter V14.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.0.0.2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Teamcenter V12.4 (All versions \u003c V12.4.0.13), Teamcenter V13.0 (All versions \u003c V13.0.0.9), Teamcenter V13.1 (All versions), Teamcenter V13.2 (All versions \u003c V13.2.0.8), Teamcenter V13.3 (All versions \u003c V13.3.0.3), Teamcenter V14.0 (All versions \u003c V14.0.0.2). The tcserver.exe binary in affected applications is vulnerable to a stack overflow condition during the parsing of user input that may lead the binary to crash."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121: Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-10T11:17:31",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-789162.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-24290",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Teamcenter V12.4",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V12.4.0.13"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Teamcenter V13.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V13.0.0.9"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Teamcenter V13.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Teamcenter V13.2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V13.2.0.8"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Teamcenter V13.3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V13.3.0.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Teamcenter V14.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V14.0.0.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Teamcenter V12.4 (All versions \u003c V12.4.0.13), Teamcenter V13.0 (All versions \u003c V13.0.0.9), Teamcenter V13.1 (All versions), Teamcenter V13.2 (All versions \u003c V13.2.0.8), Teamcenter V13.3 (All versions \u003c V13.3.0.3), Teamcenter V14.0 (All versions \u003c V14.0.0.2). The tcserver.exe binary in affected applications is vulnerable to a stack overflow condition during the parsing of user input that may lead the binary to crash."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-121: Stack-based Buffer Overflow"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-789162.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-789162.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-24290",
    "datePublished": "2022-05-10T09:46:58",
    "dateReserved": "2022-02-01T00:00:00",
    "dateUpdated": "2024-08-03T04:07:02.458Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-34661
Vulnerability from cvelistv5
Published
2022-08-10 11:18
Modified
2024-08-03 09:15
Severity ?
Summary
A vulnerability has been identified in Teamcenter V12.4 (All versions < V12.4.0.15), Teamcenter V13.0 (All versions < V13.0.0.10), Teamcenter V13.1 (All versions < V13.1.0.10), Teamcenter V13.2 (All versions < V13.2.0.9), Teamcenter V13.3 (All versions < V13.3.0.5), Teamcenter V14.0 (All versions < V14.0.0.2). File Server Cache service in Teamcenter is vulnerable to denial of service by entering infinite loops and using up CPU cycles. This could allow an attacker to cause denial of service condition.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T09:15:15.673Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-759952.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Teamcenter V12.4",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V12.4.0.15"
            }
          ]
        },
        {
          "product": "Teamcenter V13.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.0.0.10"
            }
          ]
        },
        {
          "product": "Teamcenter V13.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.1.0.10"
            }
          ]
        },
        {
          "product": "Teamcenter V13.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.2.0.9"
            }
          ]
        },
        {
          "product": "Teamcenter V13.3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.3.0.5"
            }
          ]
        },
        {
          "product": "Teamcenter V14.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.0.0.2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Teamcenter V12.4 (All versions \u003c V12.4.0.15), Teamcenter V13.0 (All versions \u003c V13.0.0.10), Teamcenter V13.1 (All versions \u003c V13.1.0.10), Teamcenter V13.2 (All versions \u003c V13.2.0.9), Teamcenter V13.3 (All versions \u003c V13.3.0.5), Teamcenter V14.0 (All versions \u003c V14.0.0.2). File Server Cache service in Teamcenter is vulnerable to denial of service by entering infinite loops and using up CPU cycles. This could allow an attacker to cause denial of service condition."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-835",
              "description": "CWE-835: Loop with Unreachable Exit Condition (\u0027Infinite Loop\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-10T11:18:07",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-759952.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-34661",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Teamcenter V12.4",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V12.4.0.15"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Teamcenter V13.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V13.0.0.10"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Teamcenter V13.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V13.1.0.10"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Teamcenter V13.2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V13.2.0.9"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Teamcenter V13.3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V13.3.0.5"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Teamcenter V14.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V14.0.0.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Teamcenter V12.4 (All versions \u003c V12.4.0.15), Teamcenter V13.0 (All versions \u003c V13.0.0.10), Teamcenter V13.1 (All versions \u003c V13.1.0.10), Teamcenter V13.2 (All versions \u003c V13.2.0.9), Teamcenter V13.3 (All versions \u003c V13.3.0.5), Teamcenter V14.0 (All versions \u003c V14.0.0.2). File Server Cache service in Teamcenter is vulnerable to denial of service by entering infinite loops and using up CPU cycles. This could allow an attacker to cause denial of service condition."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-835: Loop with Unreachable Exit Condition (\u0027Infinite Loop\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-759952.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-759952.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-34661",
    "datePublished": "2022-08-10T11:18:08",
    "dateReserved": "2022-06-27T00:00:00",
    "dateUpdated": "2024-08-03T09:15:15.673Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}