All the vulnerabilites related to PTC - ThingWorx Kepware Server
cve-2023-5908
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://www.cisa.gov/news-events/ics-advisories/icsa-23-334-03 | government-resource |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T08:14:24.586Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "government-resource", "x_transferred" ], "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-334-03" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "KEPServerEX", "vendor": "PTC", "versions": [ { "lessThanOrEqual": "6.14.263.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "ThingWorx Kepware Server", "vendor": "PTC", "versions": [ { "lessThanOrEqual": "6.14.263.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "ThingWorx Industrial Connectivity", "vendor": "PTC", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unaffected", "product": "OPC-Aggregator", "vendor": "PTC", "versions": [ { "lessThanOrEqual": "6.14", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "ThingWorx Kepware Edge", "vendor": "PTC", "versions": [ { "lessThanOrEqual": "1.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "KEPServer Enterprise", "vendor": "Rockwell Automation ", "versions": [ { "lessThanOrEqual": "6.14.263.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Industrial Gateway Server", "vendor": "GE Gigital", "versions": [ { "lessThanOrEqual": "7.614", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "TOP Server", "vendor": "Software Toolbox", "versions": [ { "lessThanOrEqual": "6.14.263.0", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "user": "00000000-0000-4000-9000-000000000000", "value": "Shawn Hoffman" } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\u003cp\u003e\u003c/p\u003e\n\n\u003cp\u003eKEPServerEX is vulnerable to a buffer overflow which may allow an attacker to crash the product being accessed or leak information.\u003c/p\u003e\u003cbr\u003e\n\n" } ], "value": "\n\n\n\n\nKEPServerEX is vulnerable to a buffer overflow which may allow an attacker to crash the product being accessed or leak information.\n\n\n\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.1, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-122", "description": "CWE-122 Heap-Based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-11-30T22:03:58.098Z", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "government-resource" ], "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-334-03" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\u003cp\u003ePTC has released and recommends users to update to the following versions:\u003c/p\u003e\u003cul\u003e\u003cli\u003eKEPServerEX should upgrade to v6.15 or later\u003c/li\u003e\u003cli\u003eThingWorx Kepware Server should upgrade to v6.15 or later\u003c/li\u003e\u003cli\u003eThingWorx Industrial Connectivity should upgrade to ThingWorx Kepware Server v6.15 or later\u003c/li\u003e\u003cli\u003eOPC-Aggregator should upgrade to v6.15 or later\u003c/li\u003e\u003cli\u003eThingWorx Kepware Edge: Upgrade to v1.8 or later\u003c/li\u003e\u003c/ul\u003e\u003cp\u003eRefer to secure configuration guide \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.ptc.com/en/support/refdoc/ThingWorx_Kepware_Server/6.15/ThingWorx%20Kepware%20Server%20Secure%20Deployment%20Guide\"\u003ehere\u003c/a\u003e\u003c/p\u003e\u003cp\u003eIf additional questions remain, please contact \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.ptc.com/apps/case_logger_viewer/cs/auth/ssl/log?\"\u003ePTC Technical Support\u003c/a\u003e\u003c/p\u003e\u003cp\u003eFor more information, see PTC\u0027s \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.ptc.com/en/support/article/CS405439\"\u003eadvisory\u003c/a\u003e.\u003c/p\u003e\n\n\u003cbr\u003e" } ], "value": "\nPTC has released and recommends users to update to the following versions:\n\n * KEPServerEX should upgrade to v6.15 or later\n * ThingWorx Kepware Server should upgrade to v6.15 or later\n * ThingWorx Industrial Connectivity should upgrade to ThingWorx Kepware Server v6.15 or later\n * OPC-Aggregator should upgrade to v6.15 or later\n * ThingWorx Kepware Edge: Upgrade to v1.8 or later\n\n\nRefer to secure configuration guide here https://www.ptc.com/en/support/refdoc/ThingWorx_Kepware_Server/6.15/ThingWorx%20Kepware%20Server%20Secure%20Deployment%20Guide \n\nIf additional questions remain, please contact PTC Technical Support https://support.ptc.com/apps/case_logger_viewer/cs/auth/ssl/log \n\nFor more information, see PTC\u0027s advisory https://www.ptc.com/en/support/article/CS405439 .\n\n\n\n\n" } ], "source": { "discovery": "UNKNOWN" }, "title": "Heap Based Buffer Overflow in PTC KEPServerEx", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2023-5908", "datePublished": "2023-11-30T22:03:58.098Z", "dateReserved": "2023-11-01T16:18:42.353Z", "dateUpdated": "2024-08-02T08:14:24.586Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-29446
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://www.cisa.gov/news-events/ics-advisories/icsa-23-243-03 | government-resource | |
https://www.ptc.com/en/support/article/cs399528 | vendor-advisory | |
https://www.dragos.com/advisory/ptcs-kepserverex-vulnerabilities/ |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T14:07:46.304Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "government-resource", "x_transferred" ], "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-243-03" }, { "tags": [ "vendor-advisory", "x_transferred" ], "url": "https://www.ptc.com/en/support/article/cs399528" }, { "tags": [ "x_transferred" ], "url": "https://www.dragos.com/advisory/ptcs-kepserverex-vulnerabilities/" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-29446", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-11-14T17:23:25.379414Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-11-14T17:23:37.514Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "platforms": [ "Windows" ], "product": "Kepware KEPServerEX", "vendor": "PTC", "versions": [ { "lessThanOrEqual": "6.14.263.0", "status": "affected", "version": "0", "versionType": "0" } ] }, { "defaultStatus": "unaffected", "platforms": [ "Windows" ], "product": "ThingWorx Kepware Server", "vendor": "PTC", "versions": [ { "lessThanOrEqual": "6.14.263.0", "status": "affected", "version": "0", "versionType": "0" } ] }, { "defaultStatus": "unaffected", "platforms": [ "Windows" ], "product": "ThingWorx Industrial Connectivity", "vendor": "PTC", "versions": [ { "lessThanOrEqual": "8.5", "status": "affected", "version": "8.0", "versionType": "0" } ] } ], "credits": [ { "lang": "en", "type": "finder", "user": "00000000-0000-4000-9000-000000000000", "value": "Sam Hanson of Dragos" } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "An improper input validation vulnerability has been discovered that could allow an adversary to inject a UNC path via a malicious project file. This allows an adversary to capture NLTMv2 hashes and potentially crack them offline.\u0026nbsp;" } ], "value": "An improper input validation vulnerability has been discovered that could allow an adversary to inject a UNC path via a malicious project file. This allows an adversary to capture NLTMv2 hashes and potentially crack them offline." } ], "impacts": [ { "capecId": "CAPEC-644", "descriptions": [ { "lang": "en", "value": "CAPEC-644 Use of Captured Hashes (Pass The Hash)" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 4.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:R/S:U/C:H/I:N/A:N", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-40", "description": "CWE-40: Path Traversal: \u0027\\\\UNC\\share\\name\\\u0027 (Windows UNC Share)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-10-08T15:13:16.725Z", "orgId": "12bdf821-1545-4a87-aac5-61670cc6fcef", "shortName": "Dragos" }, "references": [ { "tags": [ "government-resource" ], "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-243-03" }, { "tags": [ "vendor-advisory" ], "url": "https://www.ptc.com/en/support/article/cs399528" }, { "url": "https://www.dragos.com/advisory/ptcs-kepserverex-vulnerabilities/" } ], "source": { "discovery": "EXTERNAL" }, "title": "Improper Input Validation in PTC\u0027s Kepware KEPServerEX", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "12bdf821-1545-4a87-aac5-61670cc6fcef", "assignerShortName": "Dragos", "cveId": "CVE-2023-29446", "datePublished": "2024-01-10T20:21:51.434Z", "dateReserved": "2023-04-06T17:45:40.441Z", "dateUpdated": "2024-11-14T17:23:37.514Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-5909
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://www.cisa.gov/news-events/ics-advisories/icsa-23-334-03 | government-resource |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T08:14:24.693Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "government-resource", "x_transferred" ], "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-334-03" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "KEPServerEX", "vendor": "PTC", "versions": [ { "lessThanOrEqual": "6.14.263.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "ThingWorx Kepware Server", "vendor": "PTC", "versions": [ { "lessThanOrEqual": "6.14.263.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "ThingWorx Industrial Connectivity", "vendor": "PTC", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unaffected", "product": "OPC-Aggregator", "vendor": "PTC", "versions": [ { "lessThanOrEqual": "6.14", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "ThingWorx Kepware Edge", "vendor": "PTC", "versions": [ { "lessThanOrEqual": "1.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "KEPServer Enterprise", "vendor": "Rockwell Automation ", "versions": [ { "lessThanOrEqual": "6.14.263.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Industrial Gateway Server", "vendor": "GE Gigital", "versions": [ { "lessThanOrEqual": "7.614", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "TOP Server", "vendor": "Software Toolbox", "versions": [ { "lessThanOrEqual": "6.14.263.0", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "user": "00000000-0000-4000-9000-000000000000", "value": "Shawn Hoffman" } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\u003cp\u003e\u003c/p\u003e\n\n\u003cp\u003e\u003c/p\u003e\n\n\u003cp\u003eKEPServerEX does not properly validate certificates from clients which may allow unauthenticated users to connect.\u003c/p\u003e\u003cbr\u003e\n\n\u003cbr\u003e\n\n" } ], "value": "\n\n\n\n\n\n\n\n\nKEPServerEX does not properly validate certificates from clients which may allow unauthenticated users to connect.\n\n\n\n\n\n\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-297", "description": "CWE-297 Improper Validation of Certificate with Host Mismatch", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-11-30T22:05:59.595Z", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "government-resource" ], "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-334-03" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\u003cp\u003ePTC has released and recommends users to update to the following versions:\u003c/p\u003e\u003cul\u003e\u003cli\u003eKEPServerEX should upgrade to v6.15 or later\u003c/li\u003e\u003cli\u003eThingWorx Kepware Server should upgrade to v6.15 or later\u003c/li\u003e\u003cli\u003eThingWorx Industrial Connectivity should upgrade to ThingWorx Kepware Server v6.15 or later\u003c/li\u003e\u003cli\u003eOPC-Aggregator should upgrade to v6.15 or later\u003c/li\u003e\u003cli\u003eThingWorx Kepware Edge: Upgrade to v1.8 or later\u003c/li\u003e\u003c/ul\u003e\u003cp\u003eRefer to secure configuration guide \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.ptc.com/en/support/refdoc/ThingWorx_Kepware_Server/6.15/ThingWorx%20Kepware%20Server%20Secure%20Deployment%20Guide\"\u003ehere\u003c/a\u003e\u003c/p\u003e\u003cp\u003eIf additional questions remain, please contact \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.ptc.com/apps/case_logger_viewer/cs/auth/ssl/log?\"\u003ePTC Technical Support\u003c/a\u003e\u003c/p\u003e\u003cp\u003eFor more information, see PTC\u0027s \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.ptc.com/en/support/article/CS405439\"\u003eadvisory\u003c/a\u003e.\u003c/p\u003e\n\n\u003cbr\u003e" } ], "value": "\nPTC has released and recommends users to update to the following versions:\n\n * KEPServerEX should upgrade to v6.15 or later\n * ThingWorx Kepware Server should upgrade to v6.15 or later\n * ThingWorx Industrial Connectivity should upgrade to ThingWorx Kepware Server v6.15 or later\n * OPC-Aggregator should upgrade to v6.15 or later\n * ThingWorx Kepware Edge: Upgrade to v1.8 or later\n\n\nRefer to secure configuration guide here https://www.ptc.com/en/support/refdoc/ThingWorx_Kepware_Server/6.15/ThingWorx%20Kepware%20Server%20Secure%20Deployment%20Guide \n\nIf additional questions remain, please contact PTC Technical Support https://support.ptc.com/apps/case_logger_viewer/cs/auth/ssl/log \n\nFor more information, see PTC\u0027s advisory https://www.ptc.com/en/support/article/CS405439 .\n\n\n\n\n" } ], "source": { "discovery": "UNKNOWN" }, "title": "Improper Validation of Certificate with Host Mismatch in PTC KEPServerEx", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2023-5909", "datePublished": "2023-11-30T22:05:59.595Z", "dateReserved": "2023-11-01T16:18:45.060Z", "dateUpdated": "2024-08-02T08:14:24.693Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-0754
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T05:24:34.053Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-054-01" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "ThingWorx Edge C-SDK", "vendor": "PTC", "versions": [ { "lessThanOrEqual": "v2.2.12.1052 ", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": ".NET-SDK", "vendor": "Microsoft", "versions": [ { "lessThanOrEqual": "v5.8.4.971 ", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "ThingWorx Edge MicroServer (EMS)", "vendor": "PTC", "versions": [ { "lessThanOrEqual": "v5.4.10.0 ", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Kepware KEPServerEX", "vendor": "PTC", "versions": [ { "lessThanOrEqual": "v6.12 ", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "ThingWorx Kepware Server ", "vendor": "PTC", "versions": [ { "lessThanOrEqual": "v6.12 ", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "ThingWorx Industrial Connectivity", "vendor": "PTC", "versions": [ { "status": "affected", "version": "All Versions " } ] }, { "defaultStatus": "unaffected", "product": "ThingWorx Kepware Edge", "vendor": "PTC", "versions": [ { "lessThanOrEqual": "v1.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "KEPServer Enterprise ", "vendor": "Rockwell Automation ", "versions": [ { "lessThanOrEqual": "v6.12", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Digital Industrial Gateway Server ", "vendor": "General Electric ", "versions": [ { "lessThanOrEqual": "v7.612", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "user": "00000000-0000-4000-9000-000000000000", "value": "Chris Anastasio and Steven Seeley of Incite Team reported these vulnerabilities to CISA." } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cp\u003e\u003c/p\u003e\u003cp\u003eThe affected products are vulnerable to an integer\noverflow or wraparound, which could \u0026nbsp;allow an attacker to crash the server and remotely\nexecute arbitrary code.\u003c/p\u003e\n\n\n\n\n\n\u003cp\u003e\u003c/p\u003e\n\n\n\n\n\n" } ], "value": "\nThe affected products are vulnerable to an integer\noverflow or wraparound, which could \u00a0allow an attacker to crash the server and remotely\nexecute arbitrary code.\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-190", "description": "CWE-190 Integer Overflow or Wraparound", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-02-23T21:27:09.964Z", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-054-01" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cp\u003ePTC has released the following resolutions:\u003c/p\u003e\n\n\u003cp\u003eUpdate the impacted product to the latest version:\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nThingWorx Edge C-SDK: 3.0.0 or later.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nThingWorx Edge MicroServer (EMS): v5.4.11 or\nlater.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\n.NET-SDK: v5.8.5 or later.\u003c/p\u003e\n\n\u003cp\u003eFor Kepware products, the vulnerability is mitigated if the\nThingWorx Interface is \u003cb\u003enot\u003c/b\u003e enabled. To use the ThingWorx Interface\nwithout the vulnerability, update to the latest version of the product:\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nKepware KEPServerEX: v6.13 or later.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nThingWorx Kepware Server (formerly ThingWorx\nIndustrial Connectivity): v6.13 or later.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nThingWorx Kepware Edge: v1.6 or later.\u003c/p\u003e\n\n\u003cp\u003eThe following products should be upgraded as indicated or in\naccordance with the applicable organization\u2019s recommendations if the ThingWorx\nInterface is in use: \u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nRockwell Automation KEPServer Enterprise: v6.13\nor later.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nGE Digital Industrial Gateway Server: v7.613 or\nlater.\u003c/p\u003e\n\n\u003cp\u003eFor\nmore information see PTC\u2019s \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.ptc.com/en/support/article/CS385715\"\u003eCustomer Support Article\n\u003c/a\u003e.\u003c/p\u003e\n\n\n\n\n\n\u003cbr\u003e" } ], "value": "PTC has released the following resolutions:\n\n\n\nUpdate the impacted product to the latest version:\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nThingWorx Edge C-SDK: 3.0.0 or later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nThingWorx Edge MicroServer (EMS): v5.4.11 or\nlater.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\n.NET-SDK: v5.8.5 or later.\n\n\n\nFor Kepware products, the vulnerability is mitigated if the\nThingWorx Interface is not enabled. To use the ThingWorx Interface\nwithout the vulnerability, update to the latest version of the product:\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nKepware KEPServerEX: v6.13 or later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nThingWorx Kepware Server (formerly ThingWorx\nIndustrial Connectivity): v6.13 or later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nThingWorx Kepware Edge: v1.6 or later.\n\n\n\nThe following products should be upgraded as indicated or in\naccordance with the applicable organization\u2019s recommendations if the ThingWorx\nInterface is in use: \n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nRockwell Automation KEPServer Enterprise: v6.13\nor later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nGE Digital Industrial Gateway Server: v7.613 or\nlater.\n\n\n\nFor\nmore information see PTC\u2019s Customer Support Article\n.\n\n\n\n\n\n\n\n\n" } ], "source": { "discovery": "EXTERNAL" }, "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2023-0754", "datePublished": "2023-02-23T21:27:09.964Z", "dateReserved": "2023-02-08T20:15:58.394Z", "dateUpdated": "2024-08-02T05:24:34.053Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-29447
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://www.cisa.gov/news-events/ics-advisories/icsa-23-243-03 | government-resource | |
https://www.ptc.com/en/support/article/cs399528 | vendor-advisory | |
https://www.dragos.com/advisory/ptcs-kepserverex-vulnerabilities/ |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T14:07:46.417Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "government-resource", "x_transferred" ], "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-243-03" }, { "tags": [ "vendor-advisory", "x_transferred" ], "url": "https://www.ptc.com/en/support/article/cs399528" }, { "tags": [ "x_transferred" ], "url": "https://www.dragos.com/advisory/ptcs-kepserverex-vulnerabilities/" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "platforms": [ "Windows" ], "product": "Kepware KEPServerEX", "vendor": "PTC", "versions": [ { "lessThanOrEqual": "6.14.263.0", "status": "affected", "version": "0", "versionType": "0" } ] }, { "defaultStatus": "unaffected", "platforms": [ "Windows" ], "product": "ThingWorx Kepware Server", "vendor": "PTC", "versions": [ { "lessThanOrEqual": "6.14.263.0", "status": "affected", "version": "0", "versionType": "0" } ] }, { "defaultStatus": "unaffected", "platforms": [ "Windows" ], "product": "ThingWorx Industrial Connectivity", "vendor": "PTC", "versions": [ { "lessThanOrEqual": "8.5", "status": "affected", "version": "8.0", "versionType": "0" } ] } ], "credits": [ { "lang": "en", "type": "finder", "user": "00000000-0000-4000-9000-000000000000", "value": "Sam Hanson of Dragos" } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "An insufficiently protected credentials vulnerability in KEPServerEX could allow an adversary to capture user credentials as the web server uses basic authentication." } ], "value": "An insufficiently protected credentials vulnerability in KEPServerEX could allow an adversary to capture user credentials as the web server uses basic authentication." } ], "impacts": [ { "capecId": "CAPEC-94", "descriptions": [ { "lang": "en", "value": "CAPEC-94 Man in the Middle Attack" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 5.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-522", "description": "CWE-522 Insufficiently Protected Credentials", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-09-11T15:45:53.226Z", "orgId": "12bdf821-1545-4a87-aac5-61670cc6fcef", "shortName": "Dragos" }, "references": [ { "tags": [ "government-resource" ], "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-243-03" }, { "tags": [ "vendor-advisory" ], "url": "https://www.ptc.com/en/support/article/cs399528" }, { "url": "https://www.dragos.com/advisory/ptcs-kepserverex-vulnerabilities/" } ], "source": { "discovery": "EXTERNAL" }, "title": "Insufficiently Protected Credentials in PTC\u0027s Kepware KEPServerEX", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "12bdf821-1545-4a87-aac5-61670cc6fcef", "assignerShortName": "Dragos", "cveId": "CVE-2023-29447", "datePublished": "2024-01-10T20:24:52.983Z", "dateReserved": "2023-04-06T17:45:40.441Z", "dateUpdated": "2024-09-11T15:45:53.226Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-29445
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://www.cisa.gov/news-events/ics-advisories/icsa-23-243-03 | government-resource | |
https://www.ptc.com/en/support/article/cs399528 | vendor-advisory | |
https://www.dragos.com/advisory/ptcs-kepserverex-vulnerabilities/ |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T14:07:46.126Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "government-resource", "x_transferred" ], "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-243-03" }, { "tags": [ "vendor-advisory", "x_transferred" ], "url": "https://www.ptc.com/en/support/article/cs399528" }, { "tags": [ "x_transferred" ], "url": "https://www.dragos.com/advisory/ptcs-kepserverex-vulnerabilities/" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "platforms": [ "Windows" ], "product": "Kepware KEPServerEX", "vendor": "PTC", "versions": [ { "lessThanOrEqual": "6.14.263.0", "status": "affected", "version": "0", "versionType": "0" } ] }, { "defaultStatus": "unaffected", "platforms": [ "Windows" ], "product": "ThingWorx Kepware Server", "vendor": "PTC", "versions": [ { "lessThanOrEqual": "6.14.263.0", "status": "affected", "version": "0", "versionType": "0" } ] }, { "defaultStatus": "unaffected", "platforms": [ "Windows" ], "product": "ThingWorx Industrial Connectivity", "vendor": "PTC", "versions": [ { "lessThanOrEqual": "8.5", "status": "affected", "version": "8.0", "versionType": "0" } ] } ], "credits": [ { "lang": "en", "type": "finder", "user": "00000000-0000-4000-9000-000000000000", "value": "Sam Hanson of Dragos" } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "An uncontrolled search path element vulnerability (DLL hijacking) has been discovered that could allow a locally authenticated adversary to escalate privileges to SYSTEM." } ], "value": "An uncontrolled search path element vulnerability (DLL hijacking) has been discovered that could allow a locally authenticated adversary to escalate privileges to SYSTEM." } ], "impacts": [ { "capecId": "CAPEC-233", "descriptions": [ { "lang": "en", "value": "CAPEC-233 Privilege Escalation" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-427", "description": "CWE-427 Uncontrolled Search Path Element", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-01-10T20:17:12.837Z", "orgId": "12bdf821-1545-4a87-aac5-61670cc6fcef", "shortName": "Dragos" }, "references": [ { "tags": [ "government-resource" ], "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-243-03" }, { "tags": [ "vendor-advisory" ], "url": "https://www.ptc.com/en/support/article/cs399528" }, { "url": "https://www.dragos.com/advisory/ptcs-kepserverex-vulnerabilities/" } ], "source": { "discovery": "EXTERNAL" }, "title": "Uncontrolled Search Path Element in PTC\u0027s Kepware KEPServerEX", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "12bdf821-1545-4a87-aac5-61670cc6fcef", "assignerShortName": "Dragos", "cveId": "CVE-2023-29445", "datePublished": "2024-01-10T20:17:12.837Z", "dateReserved": "2023-04-06T17:45:40.441Z", "dateUpdated": "2024-08-02T14:07:46.126Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-0755
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T05:24:34.155Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-054-01" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "ThingWorx Edge C-SDK", "vendor": "PTC", "versions": [ { "lessThanOrEqual": "v2.2.12.1052 ", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": ".NET-SDK", "vendor": "Microsoft", "versions": [ { "lessThanOrEqual": "v5.8.4.971 ", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "ThingWorx Edge MicroServer (EMS)", "vendor": "PTC", "versions": [ { "lessThanOrEqual": "v5.4.10.0 ", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Kepware KEPServerEX", "vendor": "PTC", "versions": [ { "lessThanOrEqual": "v6.12 ", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "ThingWorx Kepware Server ", "vendor": "PTC", "versions": [ { "lessThanOrEqual": "v6.12 ", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "ThingWorx Industrial Connectivity", "vendor": "PTC", "versions": [ { "status": "affected", "version": "All Versions " } ] }, { "defaultStatus": "unaffected", "product": "ThingWorx Kepware Edge", "vendor": "PTC", "versions": [ { "lessThanOrEqual": "v1.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "KEPServer Enterprise ", "vendor": "Rockwell Automation ", "versions": [ { "lessThanOrEqual": "v6.12", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Digital Industrial Gateway Server ", "vendor": "General Electric ", "versions": [ { "lessThanOrEqual": "v7.612", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "user": "00000000-0000-4000-9000-000000000000", "value": "Chris Anastasio and Steven Seeley of Incite Team reported these vulnerabilities to CISA." } ], "datePublic": "2023-02-23T17:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eThe affected products are vulnerable to an improper validation of array index, which could allow an attacker to crash the server and remotely execute arbitrary code.\u003c/span\u003e\n\n" } ], "value": "\nThe affected products are vulnerable to an improper validation of array index, which could allow an attacker to crash the server and remotely execute arbitrary code.\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-129", "description": "CWE-129 Improper Validation of Array Index", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-02-23T21:23:19.210Z", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-054-01" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cp\u003ePTC has released the following resolutions:\u003c/p\u003e\n\n\u003cp\u003eUpdate the impacted product to the latest version:\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nThingWorx Edge C-SDK: 3.0.0 or later.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nThingWorx Edge MicroServer (EMS): v5.4.11 or\nlater.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\n.NET-SDK: v5.8.5 or later.\u003c/p\u003e\n\n\u003cp\u003eFor Kepware products, the vulnerability is mitigated if the\nThingWorx Interface is \u003cb\u003enot\u003c/b\u003e enabled. To use the ThingWorx Interface\nwithout the vulnerability, update to the latest version of the product:\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nKepware KEPServerEX: v6.13 or later.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nThingWorx Kepware Server (formerly ThingWorx\nIndustrial Connectivity): v6.13 or later.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nThingWorx Kepware Edge: v1.6 or later.\u003c/p\u003e\n\n\u003cp\u003eThe following products should be upgraded as indicated or in\naccordance with the applicable organization\u2019s recommendations if the ThingWorx\nInterface is in use: \u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nRockwell Automation KEPServer Enterprise: v6.13\nor later.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nGE Digital Industrial Gateway Server: v7.613 or\nlater.\u003c/p\u003e\n\n\u003cp\u003eFor\nmore information see PTC\u2019s \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.ptc.com/en/support/article/CS385715\"\u003eCustomer Support Article\n\u003c/a\u003e.\u003c/p\u003e\n\n\n\n\n\n\u003cbr\u003e" } ], "value": "PTC has released the following resolutions:\n\n\n\nUpdate the impacted product to the latest version:\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nThingWorx Edge C-SDK: 3.0.0 or later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nThingWorx Edge MicroServer (EMS): v5.4.11 or\nlater.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\n.NET-SDK: v5.8.5 or later.\n\n\n\nFor Kepware products, the vulnerability is mitigated if the\nThingWorx Interface is not enabled. To use the ThingWorx Interface\nwithout the vulnerability, update to the latest version of the product:\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nKepware KEPServerEX: v6.13 or later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nThingWorx Kepware Server (formerly ThingWorx\nIndustrial Connectivity): v6.13 or later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nThingWorx Kepware Edge: v1.6 or later.\n\n\n\nThe following products should be upgraded as indicated or in\naccordance with the applicable organization\u2019s recommendations if the ThingWorx\nInterface is in use: \n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nRockwell Automation KEPServer Enterprise: v6.13\nor later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nGE Digital Industrial Gateway Server: v7.613 or\nlater.\n\n\n\nFor\nmore information see PTC\u2019s Customer Support Article\n.\n\n\n\n\n\n\n\n\n" } ], "source": { "discovery": "EXTERNAL" }, "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2023-0755", "datePublished": "2023-02-23T21:23:19.210Z", "dateReserved": "2023-02-08T20:21:34.258Z", "dateUpdated": "2024-08-02T05:24:34.155Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-29444
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://www.cisa.gov/news-events/ics-advisories/icsa-23-243-03 | government-resource | |
https://www.ptc.com/en/support/article/cs399528 | vendor-advisory |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T14:07:46.269Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "government-resource", "x_transferred" ], "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-243-03" }, { "tags": [ "vendor-advisory", "x_transferred" ], "url": "https://www.ptc.com/en/support/article/cs399528" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "platforms": [ "Windows" ], "product": "Kepware KEPServerEX", "vendor": "PTC", "versions": [ { "lessThanOrEqual": "6.14.263.0", "status": "affected", "version": "0", "versionType": "0" } ] }, { "defaultStatus": "unaffected", "platforms": [ "Windows" ], "product": "ThingWorx Kepware Server", "vendor": "PTC", "versions": [ { "lessThanOrEqual": "6.14.263.0", "status": "affected", "version": "0", "versionType": "0" } ] }, { "defaultStatus": "unaffected", "platforms": [ "Windows" ], "product": "ThingWorx Industrial Connectivity", "vendor": "PTC", "versions": [ { "lessThanOrEqual": "8.5", "status": "affected", "version": "8.0", "versionType": "0" } ] } ], "credits": [ { "lang": "en", "type": "finder", "user": "00000000-0000-4000-9000-000000000000", "value": "Sam Hanson of Dragos" } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "An uncontrolled search path element vulnerability (DLL hijacking) has been discovered that could allow a locally authenticated adversary to escalate privileges to SYSTEM. Alternatively, they could host a trojanized version of the software and trick victims into downloading and installing their malicious version to gain initial access and code execution." } ], "value": "An uncontrolled search path element vulnerability (DLL hijacking) has been discovered that could allow a locally authenticated adversary to escalate privileges to SYSTEM. Alternatively, they could host a trojanized version of the software and trick victims into downloading and installing their malicious version to gain initial access and code execution." } ], "impacts": [ { "capecId": "CAPEC-233", "descriptions": [ { "lang": "en", "value": "CAPEC-233 Privilege Escalation" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 6.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-427", "description": "CWE-427 Uncontrolled Search Path Element", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-01-10T17:06:35.965Z", "orgId": "12bdf821-1545-4a87-aac5-61670cc6fcef", "shortName": "Dragos" }, "references": [ { "tags": [ "government-resource" ], "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-243-03" }, { "tags": [ "vendor-advisory" ], "url": "https://www.ptc.com/en/support/article/cs399528" } ], "source": { "discovery": "EXTERNAL" }, "title": "Uncontrolled Search Path Element in PTC\u0027s Kepware KEPServerEX", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "12bdf821-1545-4a87-aac5-61670cc6fcef", "assignerShortName": "Dragos", "cveId": "CVE-2023-29444", "datePublished": "2024-01-10T17:06:35.965Z", "dateReserved": "2023-04-06T17:45:40.441Z", "dateUpdated": "2024-08-02T14:07:46.269Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
var-202101-0378
Vulnerability from variot
KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server: All 6.x versions, are vulnerable to a heap-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and potentially leak data. PTC The following vulnerabilities exist in multiple products provided by the company. ‥ * Stack-based buffer overflow (CWE-121) - CVE-2020-27265 ‥ * Heap-based buffer overflow (CWE-122) - CVE-2020-27263 ‥ * Use of freed memory (use-after-free) (CWE-416) - CVE-2020-27267 ‥ * Inappropriate default permissions (CWE-276) - CVE-2020-13535The expected impact depends on each vulnerability, but it may be affected as follows. Kepware Kepserverex is an application software of American Kepware Company that can communicate with a variety of industrial equipment. The software supports more than 150 communication protocols and supports reliable real-time data for enterprises through a single platform
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202101-0378", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "thingworx kepware server", "scope": "eq", "trust": 1.0, "vendor": "ptc", "version": "6.9" }, { "model": "kepware kepserverex", "scope": "eq", "trust": 1.0, "vendor": "ptc", "version": "6.9" }, { "model": "thingworx kepware server", "scope": "eq", "trust": 1.0, "vendor": "ptc", "version": "6.8" }, { "model": "kepserver enterprise", "scope": "eq", "trust": 1.0, "vendor": "rockwellautomation", "version": "6.9.572.0" }, { "model": "industrial gateway server", "scope": "eq", "trust": 1.0, "vendor": "ge", "version": "7.68.804" }, { "model": "kepware kepserverex", "scope": "eq", "trust": 1.0, "vendor": "ptc", "version": "6.0" }, { "model": "opc-aggregator", "scope": "eq", "trust": 1.0, "vendor": "ptc", "version": null }, { "model": "kepserver enterprise", "scope": "eq", "trust": 1.0, "vendor": "rockwellautomation", "version": "6.6.504.0" }, { "model": "top server", "scope": "gte", "trust": 1.0, "vendor": "softwaretoolbox", "version": "6.0" }, { "model": "industrial gateway server", "scope": "eq", "trust": 1.0, "vendor": "ge", "version": "7.66" }, { "model": "top server", "scope": "lte", "trust": 1.0, "vendor": "softwaretoolbox", "version": "6.9" }, { "model": "thingworx industrial connectivity", "scope": "eq", "trust": 1.0, "vendor": "ptc", "version": null }, { "model": "industrial gateway server", "scope": "eq", "trust": 0.8, "vendor": "ge digital", "version": "version 7.68.804 \u304a\u3088\u3073 version 7.66" }, { "model": "kepserverex", "scope": "eq", "trust": 0.8, "vendor": "ptc", "version": "version 6.0 \u304b\u3089 version 6.9" }, { "model": "kepware linkmaster", "scope": "eq", "trust": 0.8, "vendor": "ptc", "version": "version 3.0.94.0" }, { "model": "opc-aggregator", "scope": "eq", "trust": 0.8, "vendor": "ptc", "version": "\u3059\u3079\u3066" }, { "model": "thingworx industrial connectivity", "scope": "eq", "trust": 0.8, "vendor": "ptc", "version": "\u3059\u3079\u3066" }, { "model": "thingworx kepware server", "scope": "eq", "trust": 0.8, "vendor": "ptc", "version": "version 6.8 \u304a\u3088\u3073 version 6.9" }, { "model": "kepserver enterprise", "scope": null, "trust": 0.8, "vendor": "rockwell automation", "version": null }, { "model": "top server", "scope": "eq", "trust": 0.8, "vendor": "toolbox", "version": "6\u7cfb\u306e\u3059\u3079\u3066" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-010092" }, { "db": "NVD", "id": "CVE-2020-27263" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:ge:industrial_gateway_server:7.66:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:ge:industrial_gateway_server:7.68.804:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:ptc:kepware_kepserverex:6.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:ptc:kepware_kepserverex:6.9:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:ptc:opc-aggregator:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:ptc:thingworx_industrial_connectivity:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:ptc:thingworx_kepware_server:6.8:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:ptc:thingworx_kepware_server:6.9:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:rockwellautomation:kepserver_enterprise:6.6.504.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:rockwellautomation:kepserver_enterprise:6.9.572.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:softwaretoolbox:top_server:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "6.9", "versionStartIncluding": "6.0", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2020-27263" } ] }, "cve": "CVE-2020-27263", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 6.4, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "impactScore": 4.9, "integrityImpact": "NONE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "PARTIAL", "baseScore": 6.4, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "VHN-370749", "impactScore": 4.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:N/C:P/I:N/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.1, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "impactScore": 5.2, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "IPA score", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-010092", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "IPA score", "availabilityImpact": "High", "baseScore": 9.1, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-010092", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "IPA score", "availabilityImpact": "High", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2020-010092", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Local", "author": "IPA score", "availabilityImpact": "High", "baseScore": 9.3, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-010092", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Changed", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "IPA", "id": "JVNDB-2020-010092", "trust": 2.4, "value": "Critical" }, { "author": "NVD", "id": "CVE-2020-27263", "trust": 1.0, "value": "CRITICAL" }, { "author": "IPA", "id": "JVNDB-2020-010092", "trust": 0.8, "value": "High" }, { "author": "CNNVD", "id": "CNNVD-202012-1301", "trust": 0.6, "value": "CRITICAL" }, { "author": "VULHUB", "id": "VHN-370749", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULHUB", "id": "VHN-370749" }, { "db": "JVNDB", "id": "JVNDB-2020-010092" }, { "db": "JVNDB", "id": "JVNDB-2020-010092" }, { "db": "JVNDB", "id": "JVNDB-2020-010092" }, { "db": "JVNDB", "id": "JVNDB-2020-010092" }, { "db": "NVD", "id": "CVE-2020-27263" }, { "db": "CNNVD", "id": "CNNVD-202012-1301" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server: All 6.x versions, are vulnerable to a heap-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and potentially leak data. PTC The following vulnerabilities exist in multiple products provided by the company. \u2025 * Stack-based buffer overflow (CWE-121) - CVE-2020-27265 \u2025 * Heap-based buffer overflow (CWE-122) - CVE-2020-27263 \u2025 * Use of freed memory (use-after-free) (CWE-416) - CVE-2020-27267 \u2025 * Inappropriate default permissions (CWE-276) - CVE-2020-13535The expected impact depends on each vulnerability, but it may be affected as follows. Kepware Kepserverex is an application software of American Kepware Company that can communicate with a variety of industrial equipment. The software supports more than 150 communication protocols and supports reliable real-time data for enterprises through a single platform", "sources": [ { "db": "NVD", "id": "CVE-2020-27263" }, { "db": "JVNDB", "id": "JVNDB-2020-010092" }, { "db": "VULHUB", "id": "VHN-370749" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "ICS CERT", "id": "ICSA-20-352-02", "trust": 2.5 }, { "db": "NVD", "id": "CVE-2020-27263", "trust": 2.5 }, { "db": "JVN", "id": "JVNVU98489812", "trust": 0.8 }, { "db": "ICS CERT", "id": "ICSA-20-352-03", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2020-010092", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202012-1301", "trust": 0.7 }, { "db": "AUSCERT", "id": "ESB-2020.4481", "trust": 0.6 }, { "db": "VULHUB", "id": "VHN-370749", "trust": 0.1 } ], "sources": [ { "db": "VULHUB", "id": "VHN-370749" }, { "db": "JVNDB", "id": "JVNDB-2020-010092" }, { "db": "NVD", "id": "CVE-2020-27263" }, { "db": "CNNVD", "id": "CNNVD-202012-1301" } ] }, "id": "VAR-202101-0378", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VULHUB", "id": "VHN-370749" } ], "trust": 0.01 }, "last_update_date": "2023-12-18T13:07:19.688000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Customer Center", "trust": 0.8, "url": "https://digitalsupport.ge.com/communities/cc_login?starturl=%2fen_us%2fdownload%2figs-industrial-gateway-server-v7-xx" }, { "title": "GE Digital Product Security Advisory", "trust": 0.8, "url": "https://digitalsupport.ge.com/communities/servlet/filefield?returl=%2fcommunities%2fapex%2fknowledgedetail%3fid%3dka20h0000000dpqcaa%26lang%3den_us%26type%3darticle__kav\u0026entityid=ka20h00000013uhaaq\u0026field=file_1__body__s" }, { "title": "My Kepware Customer Self-Service Portal", "trust": 0.8, "url": "https://my.kepware.com/s/login/?ec=302\u0026starturl=%2fs%2f" }, { "title": "PTC eSupport", "trust": 0.8, "url": "https://support.ptc.com/appserver/common/login/ssl/login.jsp?dest=%2fappserver%2fcs%2fportal%2f\u0026msg=1" }, { "title": "Kepserver Enterprise", "trust": 0.8, "url": "https://rockwellautomation.custhelp.com/app/products/detail/categoryrecordid/rn_product_611/p/611/~/kepserver-enterprise" }, { "title": "CISA Advisory ICSA-20-352-02 - TOP Server OPC UA Server Interface Vulnerability", "trust": 0.8, "url": "https://support.softwaretoolbox.com/app/answers/detail/a_id/3924" }, { "title": "PTC Kepware KEPServerEX Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=137540" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-010092" }, { "db": "CNNVD", "id": "CNNVD-202012-1301" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.1 }, { "problemtype": "CWE-121", "trust": 0.8 }, { "problemtype": "CWE-122", "trust": 0.8 }, { "problemtype": "CWE-416", "trust": 0.8 }, { "problemtype": "CWE-276", "trust": 0.8 } ], "sources": [ { "db": "VULHUB", "id": "VHN-370749" }, { "db": "JVNDB", "id": "JVNDB-2020-010092" }, { "db": "NVD", "id": "CVE-2020-27263" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-13535" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-27263" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-27265" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-27267" }, { "trust": 0.8, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-03" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu98489812" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2020.4481/" }, { "trust": 0.6, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-27263" } ], "sources": [ { "db": "VULHUB", "id": "VHN-370749" }, { "db": "JVNDB", "id": "JVNDB-2020-010092" }, { "db": "NVD", "id": "CVE-2020-27263" }, { "db": "CNNVD", "id": "CNNVD-202012-1301" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULHUB", "id": "VHN-370749" }, { "db": "JVNDB", "id": "JVNDB-2020-010092" }, { "db": "NVD", "id": "CVE-2020-27263" }, { "db": "CNNVD", "id": "CNNVD-202012-1301" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-01-14T00:00:00", "db": "VULHUB", "id": "VHN-370749" }, { "date": "2020-12-21T09:01:13", "db": "JVNDB", "id": "JVNDB-2020-010092" }, { "date": "2021-01-14T00:15:13.353000", "db": "NVD", "id": "CVE-2020-27263" }, { "date": "2020-12-17T00:00:00", "db": "CNNVD", "id": "CNNVD-202012-1301" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-01-21T00:00:00", "db": "VULHUB", "id": "VHN-370749" }, { "date": "2020-12-21T09:01:13", "db": "JVNDB", "id": "JVNDB-2020-010092" }, { "date": "2021-01-21T16:10:30.217000", "db": "NVD", "id": "CVE-2020-27263" }, { "date": "2021-01-22T00:00:00", "db": "CNNVD", "id": "CNNVD-202012-1301" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202012-1301" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural PTC Product vulnerabilities", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-010092" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202012-1301" } ], "trust": 0.6 } }
var-202101-0382
Vulnerability from variot
KEPServerEX v6.0 to v6.9, ThingWorx Kepware Server v6.8 and v6.9, ThingWorx Industrial Connectivity (all versions), OPC-Aggregator (all versions), Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server v7.68.804 and v7.66, and Software Toolbox TOP Server all 6.x versions, are vulnerable to a heap-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and potentially leak data. PTC The following vulnerabilities exist in multiple products provided by the company. ‥ * Stack-based buffer overflow (CWE-121) - CVE-2020-27265 ‥ * Heap-based buffer overflow (CWE-122) - CVE-2020-27263 ‥ * Use of freed memory (use-after-free) (CWE-416) - CVE-2020-27267 ‥ * Inappropriate default permissions (CWE-276) - CVE-2020-13535The expected impact depends on each vulnerability, but it may be affected as follows. Kepware Kepserverex is an application software of American Kepware Company that can communicate with a variety of industrial equipment. The software supports more than 150 communication protocols and supports reliable real-time data for enterprises through a single platform. A security vulnerability exists in PTC Kepware KEPServerEX that could allow a remote attacker to cause the application to crash
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202101-0382", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "thingworx kepware server", "scope": "eq", "trust": 1.0, "vendor": "ptc", "version": "6.9" }, { "model": "kepware kepserverex", "scope": "eq", "trust": 1.0, "vendor": "ptc", "version": "6.9" }, { "model": "thingworx kepware server", "scope": "eq", "trust": 1.0, "vendor": "ptc", "version": "6.8" }, { "model": "kepserver enterprise", "scope": "eq", "trust": 1.0, "vendor": "rockwellautomation", "version": "6.9.572.0" }, { "model": "industrial gateway server", "scope": "eq", "trust": 1.0, "vendor": "ge", "version": "7.68.804" }, { "model": "kepware kepserverex", "scope": "eq", "trust": 1.0, "vendor": "ptc", "version": "6.0" }, { "model": "opc-aggregator", "scope": "eq", "trust": 1.0, "vendor": "ptc", "version": null }, { "model": "kepserver enterprise", "scope": "eq", "trust": 1.0, "vendor": "rockwellautomation", "version": "6.6.504.0" }, { "model": "top server", "scope": "gte", "trust": 1.0, "vendor": "softwaretoolbox", "version": "6.0" }, { "model": "industrial gateway server", "scope": "eq", "trust": 1.0, "vendor": "ge", "version": "7.66" }, { "model": "top server", "scope": "lte", "trust": 1.0, "vendor": "softwaretoolbox", "version": "6.9" }, { "model": "thingworx industrial connectivity", "scope": "eq", "trust": 1.0, "vendor": "ptc", "version": null }, { "model": "industrial gateway server", "scope": "eq", "trust": 0.8, "vendor": "ge digital", "version": "version 7.68.804 \u304a\u3088\u3073 version 7.66" }, { "model": "kepserverex", "scope": "eq", "trust": 0.8, "vendor": "ptc", "version": "version 6.0 \u304b\u3089 version 6.9" }, { "model": "kepware linkmaster", "scope": "eq", "trust": 0.8, "vendor": "ptc", "version": "version 3.0.94.0" }, { "model": "opc-aggregator", "scope": "eq", "trust": 0.8, "vendor": "ptc", "version": "\u3059\u3079\u3066" }, { "model": "thingworx industrial connectivity", "scope": "eq", "trust": 0.8, "vendor": "ptc", "version": "\u3059\u3079\u3066" }, { "model": "thingworx kepware server", "scope": "eq", "trust": 0.8, "vendor": "ptc", "version": "version 6.8 \u304a\u3088\u3073 version 6.9" }, { "model": "kepserver enterprise", "scope": null, "trust": 0.8, "vendor": "rockwell automation", "version": null }, { "model": "top server", "scope": "eq", "trust": 0.8, "vendor": "toolbox", "version": "6\u7cfb\u306e\u3059\u3079\u3066" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-010092" }, { "db": "NVD", "id": "CVE-2020-27267" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:ge:industrial_gateway_server:7.66:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:ge:industrial_gateway_server:7.68.804:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:ptc:kepware_kepserverex:6.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:ptc:kepware_kepserverex:6.9:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:ptc:opc-aggregator:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:ptc:thingworx_industrial_connectivity:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:ptc:thingworx_kepware_server:6.8:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:ptc:thingworx_kepware_server:6.9:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:rockwellautomation:kepserver_enterprise:6.6.504.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:rockwellautomation:kepserver_enterprise:6.9.572.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:softwaretoolbox:top_server:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "6.9", "versionStartIncluding": "6.0", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2020-27267" } ] }, "cve": "CVE-2020-27267", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 6.4, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "impactScore": 4.9, "integrityImpact": "NONE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "PARTIAL", "baseScore": 6.4, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "VHN-370757", "impactScore": 4.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:N/C:P/I:N/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.1, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "impactScore": 5.2, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "IPA score", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-010092", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "IPA score", "availabilityImpact": "High", "baseScore": 9.1, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-010092", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "IPA score", "availabilityImpact": "High", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2020-010092", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Local", "author": "IPA score", "availabilityImpact": "High", "baseScore": 9.3, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-010092", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Changed", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "IPA", "id": "JVNDB-2020-010092", "trust": 2.4, "value": "Critical" }, { "author": "NVD", "id": "CVE-2020-27267", "trust": 1.0, "value": "CRITICAL" }, { "author": "IPA", "id": "JVNDB-2020-010092", "trust": 0.8, "value": "High" }, { "author": "CNNVD", "id": "CNNVD-202012-1299", "trust": 0.6, "value": "CRITICAL" }, { "author": "VULHUB", "id": "VHN-370757", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULHUB", "id": "VHN-370757" }, { "db": "JVNDB", "id": "JVNDB-2020-010092" }, { "db": "JVNDB", "id": "JVNDB-2020-010092" }, { "db": "JVNDB", "id": "JVNDB-2020-010092" }, { "db": "JVNDB", "id": "JVNDB-2020-010092" }, { "db": "NVD", "id": "CVE-2020-27267" }, { "db": "CNNVD", "id": "CNNVD-202012-1299" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "KEPServerEX v6.0 to v6.9, ThingWorx Kepware Server v6.8 and v6.9, ThingWorx Industrial Connectivity (all versions), OPC-Aggregator (all versions), Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server v7.68.804 and v7.66, and Software Toolbox TOP Server all 6.x versions, are vulnerable to a heap-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and potentially leak data. PTC The following vulnerabilities exist in multiple products provided by the company. \u2025 * Stack-based buffer overflow (CWE-121) - CVE-2020-27265 \u2025 * Heap-based buffer overflow (CWE-122) - CVE-2020-27263 \u2025 * Use of freed memory (use-after-free) (CWE-416) - CVE-2020-27267 \u2025 * Inappropriate default permissions (CWE-276) - CVE-2020-13535The expected impact depends on each vulnerability, but it may be affected as follows. Kepware Kepserverex is an application software of American Kepware Company that can communicate with a variety of industrial equipment. The software supports more than 150 communication protocols and supports reliable real-time data for enterprises through a single platform. A security vulnerability exists in PTC Kepware KEPServerEX that could allow a remote attacker to cause the application to crash", "sources": [ { "db": "NVD", "id": "CVE-2020-27267" }, { "db": "JVNDB", "id": "JVNDB-2020-010092" }, { "db": "VULHUB", "id": "VHN-370757" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-27267", "trust": 2.5 }, { "db": "ICS CERT", "id": "ICSA-20-352-02", "trust": 2.5 }, { "db": "JVN", "id": "JVNVU98489812", "trust": 0.8 }, { "db": "ICS CERT", "id": "ICSA-20-352-03", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2020-010092", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202012-1299", "trust": 0.7 }, { "db": "AUSCERT", "id": "ESB-2020.4481", "trust": 0.6 }, { "db": "VULHUB", "id": "VHN-370757", "trust": 0.1 } ], "sources": [ { "db": "VULHUB", "id": "VHN-370757" }, { "db": "JVNDB", "id": "JVNDB-2020-010092" }, { "db": "NVD", "id": "CVE-2020-27267" }, { "db": "CNNVD", "id": "CNNVD-202012-1299" } ] }, "id": "VAR-202101-0382", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VULHUB", "id": "VHN-370757" } ], "trust": 0.01 }, "last_update_date": "2023-12-18T13:07:19.736000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Customer Center", "trust": 0.8, "url": "https://digitalsupport.ge.com/communities/cc_login?starturl=%2fen_us%2fdownload%2figs-industrial-gateway-server-v7-xx" }, { "title": "GE Digital Product Security Advisory", "trust": 0.8, "url": "https://digitalsupport.ge.com/communities/servlet/filefield?returl=%2fcommunities%2fapex%2fknowledgedetail%3fid%3dka20h0000000dpqcaa%26lang%3den_us%26type%3darticle__kav\u0026entityid=ka20h00000013uhaaq\u0026field=file_1__body__s" }, { "title": "My Kepware Customer Self-Service Portal", "trust": 0.8, "url": "https://my.kepware.com/s/login/?ec=302\u0026starturl=%2fs%2f" }, { "title": "PTC eSupport", "trust": 0.8, "url": "https://support.ptc.com/appserver/common/login/ssl/login.jsp?dest=%2fappserver%2fcs%2fportal%2f\u0026msg=1" }, { "title": "Kepserver Enterprise", "trust": 0.8, "url": "https://rockwellautomation.custhelp.com/app/products/detail/categoryrecordid/rn_product_611/p/611/~/kepserver-enterprise" }, { "title": "CISA Advisory ICSA-20-352-02 - TOP Server OPC UA Server Interface Vulnerability", "trust": 0.8, "url": "https://support.softwaretoolbox.com/app/answers/detail/a_id/3924" }, { "title": "Kepware KEPServerEX Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=137769" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-010092" }, { "db": "CNNVD", "id": "CNNVD-202012-1299" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.1 }, { "problemtype": "CWE-121", "trust": 0.8 }, { "problemtype": "CWE-122", "trust": 0.8 }, { "problemtype": "CWE-416", "trust": 0.8 }, { "problemtype": "CWE-276", "trust": 0.8 } ], "sources": [ { "db": "VULHUB", "id": "VHN-370757" }, { "db": "JVNDB", "id": "JVNDB-2020-010092" }, { "db": "NVD", "id": "CVE-2020-27267" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-13535" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-27263" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-27265" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-27267" }, { "trust": 0.8, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-03" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu98489812" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2020.4481/" }, { "trust": 0.6, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-27267" } ], "sources": [ { "db": "VULHUB", "id": "VHN-370757" }, { "db": "JVNDB", "id": "JVNDB-2020-010092" }, { "db": "NVD", "id": "CVE-2020-27267" }, { "db": "CNNVD", "id": "CNNVD-202012-1299" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULHUB", "id": "VHN-370757" }, { "db": "JVNDB", "id": "JVNDB-2020-010092" }, { "db": "NVD", "id": "CVE-2020-27267" }, { "db": "CNNVD", "id": "CNNVD-202012-1299" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-01-14T00:00:00", "db": "VULHUB", "id": "VHN-370757" }, { "date": "2020-12-21T09:01:13", "db": "JVNDB", "id": "JVNDB-2020-010092" }, { "date": "2021-01-14T00:15:13.510000", "db": "NVD", "id": "CVE-2020-27267" }, { "date": "2020-12-17T00:00:00", "db": "CNNVD", "id": "CNNVD-202012-1299" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-01-21T00:00:00", "db": "VULHUB", "id": "VHN-370757" }, { "date": "2020-12-21T09:01:13", "db": "JVNDB", "id": "JVNDB-2020-010092" }, { "date": "2021-01-21T16:16:31.057000", "db": "NVD", "id": "CVE-2020-27267" }, { "date": "2021-01-22T00:00:00", "db": "CNNVD", "id": "CNNVD-202012-1299" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202012-1299" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural PTC Product vulnerabilities", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-010092" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202012-1299" } ], "trust": 0.6 } }
var-202101-0380
Vulnerability from variot
KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server: All 6.x versions are vulnerable to a stack-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and remotely execute code. PTC The following vulnerabilities exist in multiple products provided by the company. ‥ * Stack-based buffer overflow (CWE-121) - CVE-2020-27265 ‥ * Heap-based buffer overflow (CWE-122) - CVE-2020-27263 ‥ * Use of freed memory (use-after-free) (CWE-416) - CVE-2020-27267 ‥ * Inappropriate default permissions (CWE-276) - CVE-2020-13535The expected impact depends on each vulnerability, but it may be affected as follows. Kepware Kepserverex is an application software of American Kepware Company that can communicate with a variety of industrial equipment. The software supports more than 150 communication protocols and supports reliable real-time data for enterprises through a single platform
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202101-0380", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "thingworx kepware server", "scope": "eq", "trust": 1.0, "vendor": "ptc", "version": "6.9" }, { "model": "kepware kepserverex", "scope": "eq", "trust": 1.0, "vendor": "ptc", "version": "6.9" }, { "model": "thingworx kepware server", "scope": "eq", "trust": 1.0, "vendor": "ptc", "version": "6.8" }, { "model": "kepserver enterprise", "scope": "eq", "trust": 1.0, "vendor": "rockwellautomation", "version": "6.9.572.0" }, { "model": "industrial gateway server", "scope": "eq", "trust": 1.0, "vendor": "ge", "version": "7.68.804" }, { "model": "kepware kepserverex", "scope": "eq", "trust": 1.0, "vendor": "ptc", "version": "6.0" }, { "model": "opc-aggregator", "scope": "eq", "trust": 1.0, "vendor": "ptc", "version": null }, { "model": "kepserver enterprise", "scope": "eq", "trust": 1.0, "vendor": "rockwellautomation", "version": "6.6.504.0" }, { "model": "top server", "scope": "gte", "trust": 1.0, "vendor": "softwaretoolbox", "version": "6.0" }, { "model": "industrial gateway server", "scope": "eq", "trust": 1.0, "vendor": "ge", "version": "7.66" }, { "model": "top server", "scope": "lte", "trust": 1.0, "vendor": "softwaretoolbox", "version": "6.9" }, { "model": "thingworx industrial connectivity", "scope": "eq", "trust": 1.0, "vendor": "ptc", "version": null }, { "model": "industrial gateway server", "scope": "eq", "trust": 0.8, "vendor": "ge digital", "version": "version 7.68.804 \u304a\u3088\u3073 version 7.66" }, { "model": "kepserverex", "scope": "eq", "trust": 0.8, "vendor": "ptc", "version": "version 6.0 \u304b\u3089 version 6.9" }, { "model": "kepware linkmaster", "scope": "eq", "trust": 0.8, "vendor": "ptc", "version": "version 3.0.94.0" }, { "model": "opc-aggregator", "scope": "eq", "trust": 0.8, "vendor": "ptc", "version": "\u3059\u3079\u3066" }, { "model": "thingworx industrial connectivity", "scope": "eq", "trust": 0.8, "vendor": "ptc", "version": "\u3059\u3079\u3066" }, { "model": "thingworx kepware server", "scope": "eq", "trust": 0.8, "vendor": "ptc", "version": "version 6.8 \u304a\u3088\u3073 version 6.9" }, { "model": "kepserver enterprise", "scope": null, "trust": 0.8, "vendor": "rockwell automation", "version": null }, { "model": "top server", "scope": "eq", "trust": 0.8, "vendor": "toolbox", "version": "6\u7cfb\u306e\u3059\u3079\u3066" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-010092" }, { "db": "NVD", "id": "CVE-2020-27265" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:ge:industrial_gateway_server:7.66:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:ge:industrial_gateway_server:7.68.804:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:ptc:kepware_kepserverex:6.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:ptc:kepware_kepserverex:6.9:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:ptc:opc-aggregator:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:ptc:thingworx_industrial_connectivity:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:ptc:thingworx_kepware_server:6.8:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:ptc:thingworx_kepware_server:6.9:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:rockwellautomation:kepserver_enterprise:6.6.504.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:rockwellautomation:kepserver_enterprise:6.9.572.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:softwaretoolbox:top_server:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "6.9", "versionStartIncluding": "6.0", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2020-27265" } ] }, "cve": "CVE-2020-27265", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "VHN-370753", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "HIGH", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "IPA score", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-010092", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "IPA score", "availabilityImpact": "High", "baseScore": 9.1, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-010092", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "IPA score", "availabilityImpact": "High", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2020-010092", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Local", "author": "IPA score", "availabilityImpact": "High", "baseScore": 9.3, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-010092", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Changed", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "IPA", "id": "JVNDB-2020-010092", "trust": 2.4, "value": "Critical" }, { "author": "NVD", "id": "CVE-2020-27265", "trust": 1.0, "value": "CRITICAL" }, { "author": "IPA", "id": "JVNDB-2020-010092", "trust": 0.8, "value": "High" }, { "author": "CNNVD", "id": "CNNVD-202012-1305", "trust": 0.6, "value": "CRITICAL" }, { "author": "VULHUB", "id": "VHN-370753", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "VULHUB", "id": "VHN-370753" }, { "db": "JVNDB", "id": "JVNDB-2020-010092" }, { "db": "JVNDB", "id": "JVNDB-2020-010092" }, { "db": "JVNDB", "id": "JVNDB-2020-010092" }, { "db": "JVNDB", "id": "JVNDB-2020-010092" }, { "db": "NVD", "id": "CVE-2020-27265" }, { "db": "CNNVD", "id": "CNNVD-202012-1305" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server: All 6.x versions are vulnerable to a stack-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and remotely execute code. PTC The following vulnerabilities exist in multiple products provided by the company. \u2025 * Stack-based buffer overflow (CWE-121) - CVE-2020-27265 \u2025 * Heap-based buffer overflow (CWE-122) - CVE-2020-27263 \u2025 * Use of freed memory (use-after-free) (CWE-416) - CVE-2020-27267 \u2025 * Inappropriate default permissions (CWE-276) - CVE-2020-13535The expected impact depends on each vulnerability, but it may be affected as follows. Kepware Kepserverex is an application software of American Kepware Company that can communicate with a variety of industrial equipment. The software supports more than 150 communication protocols and supports reliable real-time data for enterprises through a single platform", "sources": [ { "db": "NVD", "id": "CVE-2020-27265" }, { "db": "JVNDB", "id": "JVNDB-2020-010092" }, { "db": "VULHUB", "id": "VHN-370753" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "ICS CERT", "id": "ICSA-20-352-02", "trust": 2.5 }, { "db": "NVD", "id": "CVE-2020-27265", "trust": 2.5 }, { "db": "JVN", "id": "JVNVU98489812", "trust": 0.8 }, { "db": "ICS CERT", "id": "ICSA-20-352-03", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2020-010092", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202012-1305", "trust": 0.7 }, { "db": "AUSCERT", "id": "ESB-2020.4481", "trust": 0.6 }, { "db": "VULHUB", "id": "VHN-370753", "trust": 0.1 } ], "sources": [ { "db": "VULHUB", "id": "VHN-370753" }, { "db": "JVNDB", "id": "JVNDB-2020-010092" }, { "db": "NVD", "id": "CVE-2020-27265" }, { "db": "CNNVD", "id": "CNNVD-202012-1305" } ] }, "id": "VAR-202101-0380", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VULHUB", "id": "VHN-370753" } ], "trust": 0.01 }, "last_update_date": "2023-12-18T13:07:19.712000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Customer Center", "trust": 0.8, "url": "https://digitalsupport.ge.com/communities/cc_login?starturl=%2fen_us%2fdownload%2figs-industrial-gateway-server-v7-xx" }, { "title": "GE Digital Product Security Advisory", "trust": 0.8, "url": "https://digitalsupport.ge.com/communities/servlet/filefield?returl=%2fcommunities%2fapex%2fknowledgedetail%3fid%3dka20h0000000dpqcaa%26lang%3den_us%26type%3darticle__kav\u0026entityid=ka20h00000013uhaaq\u0026field=file_1__body__s" }, { "title": "My Kepware Customer Self-Service Portal", "trust": 0.8, "url": "https://my.kepware.com/s/login/?ec=302\u0026starturl=%2fs%2f" }, { "title": "PTC eSupport", "trust": 0.8, "url": "https://support.ptc.com/appserver/common/login/ssl/login.jsp?dest=%2fappserver%2fcs%2fportal%2f\u0026msg=1" }, { "title": "Kepserver Enterprise", "trust": 0.8, "url": "https://rockwellautomation.custhelp.com/app/products/detail/categoryrecordid/rn_product_611/p/611/~/kepserver-enterprise" }, { "title": "CISA Advisory ICSA-20-352-02 - TOP Server OPC UA Server Interface Vulnerability", "trust": 0.8, "url": "https://support.softwaretoolbox.com/app/answers/detail/a_id/3924" }, { "title": "Multiple Kepware Product security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=137773" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-010092" }, { "db": "CNNVD", "id": "CNNVD-202012-1305" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.1 }, { "problemtype": "CWE-121", "trust": 0.8 }, { "problemtype": "CWE-122", "trust": 0.8 }, { "problemtype": "CWE-416", "trust": 0.8 }, { "problemtype": "CWE-276", "trust": 0.8 } ], "sources": [ { "db": "VULHUB", "id": "VHN-370753" }, { "db": "JVNDB", "id": "JVNDB-2020-010092" }, { "db": "NVD", "id": "CVE-2020-27265" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-13535" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-27263" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-27265" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-27267" }, { "trust": 0.8, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-352-03" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu98489812" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2020.4481/" }, { "trust": 0.6, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-27265" } ], "sources": [ { "db": "VULHUB", "id": "VHN-370753" }, { "db": "JVNDB", "id": "JVNDB-2020-010092" }, { "db": "NVD", "id": "CVE-2020-27265" }, { "db": "CNNVD", "id": "CNNVD-202012-1305" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULHUB", "id": "VHN-370753" }, { "db": "JVNDB", "id": "JVNDB-2020-010092" }, { "db": "NVD", "id": "CVE-2020-27265" }, { "db": "CNNVD", "id": "CNNVD-202012-1305" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-01-14T00:00:00", "db": "VULHUB", "id": "VHN-370753" }, { "date": "2020-12-21T09:01:13", "db": "JVNDB", "id": "JVNDB-2020-010092" }, { "date": "2021-01-14T00:15:13.417000", "db": "NVD", "id": "CVE-2020-27265" }, { "date": "2020-12-17T00:00:00", "db": "CNNVD", "id": "CNNVD-202012-1305" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-01-21T00:00:00", "db": "VULHUB", "id": "VHN-370753" }, { "date": "2020-12-21T09:01:13", "db": "JVNDB", "id": "JVNDB-2020-010092" }, { "date": "2021-01-21T16:20:52.077000", "db": "NVD", "id": "CVE-2020-27265" }, { "date": "2021-01-22T00:00:00", "db": "CNNVD", "id": "CNNVD-202012-1305" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202012-1305" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural PTC Product vulnerabilities", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-010092" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202012-1305" } ], "trust": 0.6 } }