cve-2023-29444
Vulnerability from cvelistv5
Published
2024-01-10 17:06
Modified
2024-08-02 14:07
Summary
Uncontrolled Search Path Element in PTC's Kepware KEPServerEX
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:07:46.269Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-243-03"
          },
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.ptc.com/en/support/article/cs399528"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Windows"
          ],
          "product": "Kepware KEPServerEX",
          "vendor": "PTC",
          "versions": [
            {
              "lessThanOrEqual": "6.14.263.0",
              "status": "affected",
              "version": "0",
              "versionType": "0"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Windows"
          ],
          "product": "ThingWorx Kepware Server",
          "vendor": "PTC",
          "versions": [
            {
              "lessThanOrEqual": "6.14.263.0",
              "status": "affected",
              "version": "0",
              "versionType": "0"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Windows"
          ],
          "product": "ThingWorx Industrial Connectivity",
          "vendor": "PTC",
          "versions": [
            {
              "lessThanOrEqual": "8.5",
              "status": "affected",
              "version": "8.0",
              "versionType": "0"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Sam Hanson of Dragos"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An uncontrolled search path element vulnerability (DLL hijacking) has been discovered that could allow a locally authenticated adversary to escalate privileges to SYSTEM. Alternatively, they could host a trojanized version of the software and trick victims into downloading and installing their malicious version to gain initial access and code execution."
            }
          ],
          "value": "An uncontrolled search path element vulnerability (DLL hijacking) has been discovered that could allow a locally authenticated adversary to escalate privileges to SYSTEM. Alternatively, they could host a trojanized version of the software and trick victims into downloading and installing their malicious version to gain initial access and code execution."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-233",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-233 Privilege Escalation"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-427",
              "description": "CWE-427 Uncontrolled Search Path Element",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-01-10T17:06:35.965Z",
        "orgId": "12bdf821-1545-4a87-aac5-61670cc6fcef",
        "shortName": "Dragos"
      },
      "references": [
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-243-03"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.ptc.com/en/support/article/cs399528"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Uncontrolled Search Path Element in PTC\u0027s Kepware KEPServerEX",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "12bdf821-1545-4a87-aac5-61670cc6fcef",
    "assignerShortName": "Dragos",
    "cveId": "CVE-2023-29444",
    "datePublished": "2024-01-10T17:06:35.965Z",
    "dateReserved": "2023-04-06T17:45:40.441Z",
    "dateUpdated": "2024-08-02T14:07:46.269Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2023-29444\",\"sourceIdentifier\":\"ot-cert@dragos.com\",\"published\":\"2024-01-10T17:15:08.493\",\"lastModified\":\"2024-01-19T17:36:09.637\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"An uncontrolled search path element vulnerability (DLL hijacking) has been discovered that could allow a locally authenticated adversary to escalate privileges to SYSTEM. Alternatively, they could host a trojanized version of the software and trick victims into downloading and installing their malicious version to gain initial access and code execution.\"},{\"lang\":\"es\",\"value\":\"Se ha descubierto una vulnerabilidad de elemento de ruta de b\u00fasqueda no controlada (secuestro de DLL) que podr\u00eda permitir a un adversario autenticado localmente escalar privilegios a SYSTEM. Alternativamente, podr\u00edan alojar una versi\u00f3n con troyano del software y enga\u00f1ar a las v\u00edctimas para que descarguen e instalen su versi\u00f3n maliciosa para obtener acceso inicial y ejecuci\u00f3n del c\u00f3digo.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.3,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.3,\"impactScore\":5.9},{\"source\":\"ot-cert@dragos.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:U/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":6.3,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":0.3,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-427\"}]},{\"source\":\"ot-cert@dragos.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-427\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ptc:kepware_kepserverex:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"6.0.2107.0\",\"versionEndIncluding\":\"6.14.263.0\",\"matchCriteriaId\":\"BE266C92-959F-41CE-A8DA-DC3D336BC169\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ptc:thingworx_kepware_server:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"6.8\",\"versionEndIncluding\":\"6.14.263.0\",\"matchCriteriaId\":\"99455409-195C-418C-A227-E9C67E70C2F3\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ptc:thingworx_industrial_connectivity:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"8.0\",\"versionEndIncluding\":\"8.5\",\"matchCriteriaId\":\"10F80877-E2FA-4800-B4EB-BC87E35A9441\"}]}]}],\"references\":[{\"url\":\"https://www.cisa.gov/news-events/ics-advisories/icsa-23-243-03\",\"source\":\"ot-cert@dragos.com\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://www.ptc.com/en/support/article/cs399528\",\"source\":\"ot-cert@dragos.com\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.