All the vulnerabilites related to GE - UR family
cve-2021-27420
Vulnerability from cvelistv5
Published
2022-03-23 19:46
Modified
2024-08-03 20:48
Severity ?
EPSS score ?
Summary
GE UR family input validation
References
▼ | URL | Tags |
---|---|---|
https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02 | x_refsource_CONFIRM | |
https://www.gegridsolutions.com/Passport/Login.aspx | x_refsource_CONFIRM |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T20:48:17.154Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://www.gegridsolutions.com/Passport/Login.aspx" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "UR family", "vendor": "GE", "versions": [ { "lessThan": "8.1x", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "value": "SCADA-X, DOE\u2019s Cyber Testing for Resilient Industrial Control Systems (CyTRICS) program, Verve Industrial, and VuMetric reported these vulnerabilities to GE." } ], "descriptions": [ { "lang": "en", "value": "GE UR firmware versions prior to version 8.1x web server task does not properly handle receipt of unsupported HTTP verbs, resulting in the web server becoming temporarily unresponsive after receiving a series of unsupported HTTP requests. When unresponsive, the web server is inaccessible. By itself, this is not particularly significant as the relay remains effective in all other functionality and communication channels." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-20", "description": "CWE-20 Improper Input Validation", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-03-23T19:46:24", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://www.gegridsolutions.com/Passport/Login.aspx" } ], "solutions": [ { "lang": "en", "value": "GE strongly recommends users with impacted firmware versions update their UR devices to UR firmware Version 8.10, or greater to resolve these vulnerabilities. GE provides additional mitigations and information about these vulnerabilities in GE Publication Number: GES-2021-004 (login required)." } ], "source": { "discovery": "EXTERNAL" }, "title": "GE UR family input validation", "workarounds": [ { "lang": "en", "value": "GE recommends protecting UR IED by using network defense-in-depth practices. This includes, but is not limited to, placing UR IED inside the control system network security perimeter, and having access controls, monitoring (such as an Intrusion Detection System), and other mitigating technologies in place. \n\nGE recommends users refer to the UR Deployment guide for secure configuration of UR IED and system." } ], "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2021-27420", "STATE": "PUBLIC", "TITLE": "GE UR family input validation" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "UR family", "version": { "version_data": [ { "version_affected": "\u003c", "version_value": "8.1x" } ] } } ] }, "vendor_name": "GE" } ] } }, "credit": [ { "lang": "eng", "value": "SCADA-X, DOE\u2019s Cyber Testing for Resilient Industrial Control Systems (CyTRICS) program, Verve Industrial, and VuMetric reported these vulnerabilities to GE." } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "GE UR firmware versions prior to version 8.1x web server task does not properly handle receipt of unsupported HTTP verbs, resulting in the web server becoming temporarily unresponsive after receiving a series of unsupported HTTP requests. When unresponsive, the web server is inaccessible. By itself, this is not particularly significant as the relay remains effective in all other functionality and communication channels." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-20 Improper Input Validation" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02", "refsource": "CONFIRM", "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02" }, { "name": "https://www.gegridsolutions.com/Passport/Login.aspx", "refsource": "CONFIRM", "url": "https://www.gegridsolutions.com/Passport/Login.aspx" } ] }, "solution": [ { "lang": "en", "value": "GE strongly recommends users with impacted firmware versions update their UR devices to UR firmware Version 8.10, or greater to resolve these vulnerabilities. GE provides additional mitigations and information about these vulnerabilities in GE Publication Number: GES-2021-004 (login required)." } ], "source": { "discovery": "EXTERNAL" }, "work_around": [ { "lang": "en", "value": "GE recommends protecting UR IED by using network defense-in-depth practices. This includes, but is not limited to, placing UR IED inside the control system network security perimeter, and having access controls, monitoring (such as an Intrusion Detection System), and other mitigating technologies in place. \n\nGE recommends users refer to the UR Deployment guide for secure configuration of UR IED and system." } ] } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2021-27420", "datePublished": "2022-03-23T19:46:24", "dateReserved": "2021-02-19T00:00:00", "dateUpdated": "2024-08-03T20:48:17.154Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-27418
Vulnerability from cvelistv5
Published
2022-03-23 19:46
Modified
2024-08-03 20:48
Severity ?
EPSS score ?
Summary
GE UR family input validation
References
▼ | URL | Tags |
---|---|---|
https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02 | x_refsource_CONFIRM | |
https://www.gegridsolutions.com/Passport/Login.aspx | x_refsource_CONFIRM |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T20:48:17.146Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://www.gegridsolutions.com/Passport/Login.aspx" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "UR family", "vendor": "GE", "versions": [ { "lessThan": "8.1x", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "value": "SCADA-X, DOE\u2019s Cyber Testing for Resilient Industrial Control Systems (CyTRICS) program, Verve Industrial, and VuMetric reported these vulnerabilities to GE." } ], "descriptions": [ { "lang": "en", "value": "GE UR firmware versions prior to version 8.1x supports web interface with read-only access. The device fails to properly validate user input, making it possible to perform cross-site scripting attacks, which may be used to send a malicious script. Also, UR Firmware web server does not perform HTML encoding of user-supplied strings." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-20", "description": "CWE-20 Improper Input Validation", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-03-23T19:46:23", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://www.gegridsolutions.com/Passport/Login.aspx" } ], "solutions": [ { "lang": "en", "value": "GE strongly recommends users with impacted firmware versions update their UR devices to UR firmware Version 8.10, or greater to resolve these vulnerabilities. GE provides additional mitigations and information about these vulnerabilities in GE Publication Number: GES-2021-004 (login required)." } ], "source": { "discovery": "EXTERNAL" }, "title": "GE UR family input validation", "workarounds": [ { "lang": "en", "value": "GE recommends protecting UR IED by using network defense-in-depth practices. This includes, but is not limited to, placing UR IED inside the control system network security perimeter, and having access controls, monitoring (such as an Intrusion Detection System), and other mitigating technologies in place. \n\nGE recommends users refer to the UR Deployment guide for secure configuration of UR IED and system." } ], "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2021-27418", "STATE": "PUBLIC", "TITLE": "GE UR family input validation" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "UR family", "version": { "version_data": [ { "version_affected": "\u003c", "version_value": "8.1x" } ] } } ] }, "vendor_name": "GE" } ] } }, "credit": [ { "lang": "eng", "value": "SCADA-X, DOE\u2019s Cyber Testing for Resilient Industrial Control Systems (CyTRICS) program, Verve Industrial, and VuMetric reported these vulnerabilities to GE." } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "GE UR firmware versions prior to version 8.1x supports web interface with read-only access. The device fails to properly validate user input, making it possible to perform cross-site scripting attacks, which may be used to send a malicious script. Also, UR Firmware web server does not perform HTML encoding of user-supplied strings." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-20 Improper Input Validation" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02", "refsource": "CONFIRM", "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02" }, { "name": "https://www.gegridsolutions.com/Passport/Login.aspx", "refsource": "CONFIRM", "url": "https://www.gegridsolutions.com/Passport/Login.aspx" } ] }, "solution": [ { "lang": "en", "value": "GE strongly recommends users with impacted firmware versions update their UR devices to UR firmware Version 8.10, or greater to resolve these vulnerabilities. GE provides additional mitigations and information about these vulnerabilities in GE Publication Number: GES-2021-004 (login required)." } ], "source": { "discovery": "EXTERNAL" }, "work_around": [ { "lang": "en", "value": "GE recommends protecting UR IED by using network defense-in-depth practices. This includes, but is not limited to, placing UR IED inside the control system network security perimeter, and having access controls, monitoring (such as an Intrusion Detection System), and other mitigating technologies in place. \n\nGE recommends users refer to the UR Deployment guide for secure configuration of UR IED and system." } ] } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2021-27418", "datePublished": "2022-03-23T19:46:23", "dateReserved": "2021-02-19T00:00:00", "dateUpdated": "2024-08-03T20:48:17.146Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-27422
Vulnerability from cvelistv5
Published
2022-03-23 19:46
Modified
2024-08-03 20:48
Severity ?
EPSS score ?
Summary
GE UR family exposure of sensitive information to an unauthorized actor
References
▼ | URL | Tags |
---|---|---|
https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02 | x_refsource_CONFIRM | |
https://www.gegridsolutions.com/Passport/Login.aspx | x_refsource_CONFIRM |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T20:48:17.116Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://www.gegridsolutions.com/Passport/Login.aspx" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "UR family", "vendor": "GE", "versions": [ { "lessThan": "8.1x", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "value": "SCADA-X, DOE\u2019s Cyber Testing for Resilient Industrial Control Systems (CyTRICS) program, Verve Industrial, and VuMetric reported these vulnerabilities to GE." } ], "descriptions": [ { "lang": "en", "value": "GE UR firmware versions prior to version 8.1x web server interface is supported on UR over HTTP protocol. It allows sensitive information exposure without authentication." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-200", "description": "CWE-200 Information Exposure", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-03-23T19:46:28", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://www.gegridsolutions.com/Passport/Login.aspx" } ], "solutions": [ { "lang": "en", "value": "GE strongly recommends users with impacted firmware versions update their UR devices to UR firmware Version 8.10, or greater to resolve these vulnerabilities. GE provides additional mitigations and information about these vulnerabilities in GE Publication Number: GES-2021-004 (login required)." } ], "source": { "discovery": "EXTERNAL" }, "title": "GE UR family exposure of sensitive information to an unauthorized actor", "workarounds": [ { "lang": "en", "value": "GE recommends protecting UR IED by using network defense-in-depth practices. This includes, but is not limited to, placing UR IED inside the control system network security perimeter, and having access controls, monitoring (such as an Intrusion Detection System), and other mitigating technologies in place. \n\nGE recommends users refer to the UR Deployment guide for secure configuration of UR IED and system." } ], "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2021-27422", "STATE": "PUBLIC", "TITLE": "GE UR family exposure of sensitive information to an unauthorized actor" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "UR family", "version": { "version_data": [ { "version_affected": "\u003c", "version_value": "8.1x" } ] } } ] }, "vendor_name": "GE" } ] } }, "credit": [ { "lang": "eng", "value": "SCADA-X, DOE\u2019s Cyber Testing for Resilient Industrial Control Systems (CyTRICS) program, Verve Industrial, and VuMetric reported these vulnerabilities to GE." } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "GE UR firmware versions prior to version 8.1x web server interface is supported on UR over HTTP protocol. It allows sensitive information exposure without authentication." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-200 Information Exposure" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02", "refsource": "CONFIRM", "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02" }, { "name": "https://www.gegridsolutions.com/Passport/Login.aspx", "refsource": "CONFIRM", "url": "https://www.gegridsolutions.com/Passport/Login.aspx" } ] }, "solution": [ { "lang": "en", "value": "GE strongly recommends users with impacted firmware versions update their UR devices to UR firmware Version 8.10, or greater to resolve these vulnerabilities. GE provides additional mitigations and information about these vulnerabilities in GE Publication Number: GES-2021-004 (login required)." } ], "source": { "discovery": "EXTERNAL" }, "work_around": [ { "lang": "en", "value": "GE recommends protecting UR IED by using network defense-in-depth practices. This includes, but is not limited to, placing UR IED inside the control system network security perimeter, and having access controls, monitoring (such as an Intrusion Detection System), and other mitigating technologies in place. \n\nGE recommends users refer to the UR Deployment guide for secure configuration of UR IED and system." } ] } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2021-27422", "datePublished": "2022-03-23T19:46:28", "dateReserved": "2021-02-19T00:00:00", "dateUpdated": "2024-08-03T20:48:17.116Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-27428
Vulnerability from cvelistv5
Published
2022-03-23 19:46
Modified
2024-08-03 20:48
Severity ?
EPSS score ?
Summary
GE UR family Unrestricted Upload of File with Dangerous Type
References
▼ | URL | Tags |
---|---|---|
https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02 | x_refsource_CONFIRM | |
https://www.gegridsolutions.com/Passport/Login.aspx | x_refsource_CONFIRM |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T20:48:17.217Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://www.gegridsolutions.com/Passport/Login.aspx" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "UR family", "vendor": "GE", "versions": [ { "lessThan": "8.1x", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "value": "SCADA-X, DOE\u2019s Cyber Testing for Resilient Industrial Control Systems (CyTRICS) program, Verve Industrial, and VuMetric reported these vulnerabilities to GE." } ], "descriptions": [ { "lang": "en", "value": "GE UR IED firmware versions prior to version 8.1x supports upgrading firmware using UR Setup configuration tool \u2013 Enervista UR Setup. This UR Setup tool validates the authenticity and integrity of firmware file before uploading the UR IED. An illegitimate user could upgrade firmware without appropriate privileges. The weakness is assessed, and mitigation is implemented in firmware Version 8.10." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-434", "description": "CWE-434 Unrestricted Upload of File with Dangerous Type", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-03-23T19:46:25", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://www.gegridsolutions.com/Passport/Login.aspx" } ], "solutions": [ { "lang": "en", "value": "GE strongly recommends users with impacted firmware versions update their UR devices to UR firmware Version 8.10, or greater to resolve these vulnerabilities. GE provides additional mitigations and information about these vulnerabilities in GE Publication Number: GES-2021-004 (login required)." } ], "source": { "discovery": "EXTERNAL" }, "title": "GE UR family Unrestricted Upload of File with Dangerous Type", "workarounds": [ { "lang": "en", "value": "GE recommends protecting UR IED by using network defense-in-depth practices. This includes, but is not limited to, placing UR IED inside the control system network security perimeter, and having access controls, monitoring (such as an Intrusion Detection System), and other mitigating technologies in place. \n\nGE recommends users refer to the UR Deployment guide for secure configuration of UR IED and system." } ], "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2021-27428", "STATE": "PUBLIC", "TITLE": "GE UR family Unrestricted Upload of File with Dangerous Type" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "UR family", "version": { "version_data": [ { "version_affected": "\u003c", "version_value": "8.1x" } ] } } ] }, "vendor_name": "GE" } ] } }, "credit": [ { "lang": "eng", "value": "SCADA-X, DOE\u2019s Cyber Testing for Resilient Industrial Control Systems (CyTRICS) program, Verve Industrial, and VuMetric reported these vulnerabilities to GE." } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "GE UR IED firmware versions prior to version 8.1x supports upgrading firmware using UR Setup configuration tool \u2013 Enervista UR Setup. This UR Setup tool validates the authenticity and integrity of firmware file before uploading the UR IED. An illegitimate user could upgrade firmware without appropriate privileges. The weakness is assessed, and mitigation is implemented in firmware Version 8.10." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-434 Unrestricted Upload of File with Dangerous Type" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02", "refsource": "CONFIRM", "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02" }, { "name": "https://www.gegridsolutions.com/Passport/Login.aspx", "refsource": "CONFIRM", "url": "https://www.gegridsolutions.com/Passport/Login.aspx" } ] }, "solution": [ { "lang": "en", "value": "GE strongly recommends users with impacted firmware versions update their UR devices to UR firmware Version 8.10, or greater to resolve these vulnerabilities. GE provides additional mitigations and information about these vulnerabilities in GE Publication Number: GES-2021-004 (login required)." } ], "source": { "discovery": "EXTERNAL" }, "work_around": [ { "lang": "en", "value": "GE recommends protecting UR IED by using network defense-in-depth practices. This includes, but is not limited to, placing UR IED inside the control system network security perimeter, and having access controls, monitoring (such as an Intrusion Detection System), and other mitigating technologies in place. \n\nGE recommends users refer to the UR Deployment guide for secure configuration of UR IED and system." } ] } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2021-27428", "datePublished": "2022-03-23T19:46:25", "dateReserved": "2021-02-19T00:00:00", "dateUpdated": "2024-08-03T20:48:17.217Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-27424
Vulnerability from cvelistv5
Published
2022-03-23 19:46
Modified
2024-08-03 20:48
Severity ?
EPSS score ?
Summary
GE UR family exposure of sensitive information to an unauthorized actor
References
▼ | URL | Tags |
---|---|---|
https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02 | x_refsource_CONFIRM | |
https://www.gegridsolutions.com/Passport/Login.aspx | x_refsource_CONFIRM |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T20:48:17.121Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://www.gegridsolutions.com/Passport/Login.aspx" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "UR family", "vendor": "GE", "versions": [ { "lessThan": "8.1x", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "value": "SCADA-X, DOE\u2019s Cyber Testing for Resilient Industrial Control Systems (CyTRICS) program, Verve Industrial, and VuMetric reported these vulnerabilities to GE." } ], "descriptions": [ { "lang": "en", "value": "GE UR firmware versions prior to version 8.1x shares MODBUS memory map as part of the communications guide. GE was made aware a \u201cLast-key pressed\u201d MODBUS register can be used to gain unauthorized information." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-200", "description": "CWE-200 Information Exposure", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-03-23T19:46:25", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://www.gegridsolutions.com/Passport/Login.aspx" } ], "solutions": [ { "lang": "en", "value": "GE strongly recommends users with impacted firmware versions update their UR devices to UR firmware Version 8.10, or greater to resolve these vulnerabilities. GE provides additional mitigations and information about these vulnerabilities in GE Publication Number: GES-2021-004 (login required)." } ], "source": { "discovery": "EXTERNAL" }, "title": "GE UR family exposure of sensitive information to an unauthorized actor", "workarounds": [ { "lang": "en", "value": "GE recommends protecting UR IED by using network defense-in-depth practices. This includes, but is not limited to, placing UR IED inside the control system network security perimeter, and having access controls, monitoring (such as an Intrusion Detection System), and other mitigating technologies in place. \n\nGE recommends users refer to the UR Deployment guide for secure configuration of UR IED and system." } ], "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2021-27424", "STATE": "PUBLIC", "TITLE": "GE UR family exposure of sensitive information to an unauthorized actor" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "UR family", "version": { "version_data": [ { "version_affected": "\u003c", "version_value": "8.1x" } ] } } ] }, "vendor_name": "GE" } ] } }, "credit": [ { "lang": "eng", "value": "SCADA-X, DOE\u2019s Cyber Testing for Resilient Industrial Control Systems (CyTRICS) program, Verve Industrial, and VuMetric reported these vulnerabilities to GE." } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "GE UR firmware versions prior to version 8.1x shares MODBUS memory map as part of the communications guide. GE was made aware a \u201cLast-key pressed\u201d MODBUS register can be used to gain unauthorized information." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-200 Information Exposure" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02", "refsource": "CONFIRM", "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02" }, { "name": "https://www.gegridsolutions.com/Passport/Login.aspx", "refsource": "CONFIRM", "url": "https://www.gegridsolutions.com/Passport/Login.aspx" } ] }, "solution": [ { "lang": "en", "value": "GE strongly recommends users with impacted firmware versions update their UR devices to UR firmware Version 8.10, or greater to resolve these vulnerabilities. GE provides additional mitigations and information about these vulnerabilities in GE Publication Number: GES-2021-004 (login required)." } ], "source": { "discovery": "EXTERNAL" }, "work_around": [ { "lang": "en", "value": "GE recommends protecting UR IED by using network defense-in-depth practices. This includes, but is not limited to, placing UR IED inside the control system network security perimeter, and having access controls, monitoring (such as an Intrusion Detection System), and other mitigating technologies in place. \n\nGE recommends users refer to the UR Deployment guide for secure configuration of UR IED and system." } ] } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2021-27424", "datePublished": "2022-03-23T19:46:25", "dateReserved": "2021-02-19T00:00:00", "dateUpdated": "2024-08-03T20:48:17.121Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-27426
Vulnerability from cvelistv5
Published
2022-03-23 19:46
Modified
2024-08-03 20:48
Severity ?
EPSS score ?
Summary
GE UR family insecure default variable initialization
References
▼ | URL | Tags |
---|---|---|
https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02 | x_refsource_CONFIRM | |
https://www.gegridsolutions.com/Passport/Login.aspx | x_refsource_CONFIRM |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T20:48:17.118Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://www.gegridsolutions.com/Passport/Login.aspx" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "UR family", "vendor": "GE", "versions": [ { "lessThan": "8.1x", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "value": "SCADA-X, DOE\u2019s Cyber Testing for Resilient Industrial Control Systems (CyTRICS) program, Verve Industrial, and VuMetric reported these vulnerabilities to GE." } ], "descriptions": [ { "lang": "en", "value": "GE UR IED firmware versions prior to version 8.1x with \u201cBasic\u201d security variant does not allow the disabling of the \u201cFactory Mode,\u201d which is used for servicing the IED by a \u201cFactory\u201d user." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-453", "description": "CWE-453 Insecure Default Variable Initialization", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-03-23T19:46:27", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://www.gegridsolutions.com/Passport/Login.aspx" } ], "solutions": [ { "lang": "en", "value": "GE strongly recommends users with impacted firmware versions update their UR devices to UR firmware Version 8.10, or greater to resolve these vulnerabilities. GE provides additional mitigations and information about these vulnerabilities in GE Publication Number: GES-2021-004 (login required)." } ], "source": { "discovery": "EXTERNAL" }, "title": "GE UR family insecure default variable initialization", "workarounds": [ { "lang": "en", "value": "GE recommends protecting UR IED by using network defense-in-depth practices. This includes, but is not limited to, placing UR IED inside the control system network security perimeter, and having access controls, monitoring (such as an Intrusion Detection System), and other mitigating technologies in place. \n\nGE recommends users refer to the UR Deployment guide for secure configuration of UR IED and system." } ], "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2021-27426", "STATE": "PUBLIC", "TITLE": "GE UR family insecure default variable initialization" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "UR family", "version": { "version_data": [ { "version_affected": "\u003c", "version_value": "8.1x" } ] } } ] }, "vendor_name": "GE" } ] } }, "credit": [ { "lang": "eng", "value": "SCADA-X, DOE\u2019s Cyber Testing for Resilient Industrial Control Systems (CyTRICS) program, Verve Industrial, and VuMetric reported these vulnerabilities to GE." } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "GE UR IED firmware versions prior to version 8.1x with \u201cBasic\u201d security variant does not allow the disabling of the \u201cFactory Mode,\u201d which is used for servicing the IED by a \u201cFactory\u201d user." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-453 Insecure Default Variable Initialization" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02", "refsource": "CONFIRM", "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02" }, { "name": "https://www.gegridsolutions.com/Passport/Login.aspx", "refsource": "CONFIRM", "url": "https://www.gegridsolutions.com/Passport/Login.aspx" } ] }, "solution": [ { "lang": "en", "value": "GE strongly recommends users with impacted firmware versions update their UR devices to UR firmware Version 8.10, or greater to resolve these vulnerabilities. GE provides additional mitigations and information about these vulnerabilities in GE Publication Number: GES-2021-004 (login required)." } ], "source": { "discovery": "EXTERNAL" }, "work_around": [ { "lang": "en", "value": "GE recommends protecting UR IED by using network defense-in-depth practices. This includes, but is not limited to, placing UR IED inside the control system network security perimeter, and having access controls, monitoring (such as an Intrusion Detection System), and other mitigating technologies in place. \n\nGE recommends users refer to the UR Deployment guide for secure configuration of UR IED and system." } ] } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2021-27426", "datePublished": "2022-03-23T19:46:27", "dateReserved": "2021-02-19T00:00:00", "dateUpdated": "2024-08-03T20:48:17.118Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }