Search criteria
5 vulnerabilities found for Video Recording Manager by Bosch
CVE-2023-32230 (GCVE-0-2023-32230)
Vulnerability from cvelistv5 – Published: 2023-12-18 12:58 – Updated: 2024-08-02 15:10- CWE-703 - Improper Check or Handling of Exceptional Conditions
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Bosch | Video Recording Manager |
Affected:
0 , ≤ 04.10.0079
(custom)
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T15:10:24.221Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-092656-BT.html",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-092656-BT.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Video Recording Manager",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "04.10.0079",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"product": "Video Streaming Gateway",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "8.1.2.2",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThanOrEqual": "9.0.0.178",
"status": "affected",
"version": "9.0.0",
"versionType": "custom"
}
]
},
{
"product": "Monitorwall",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "10.00.0164",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"product": "VJD-7513",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "10.40.0055",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"product": "VJD-7523",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "10.40.0055",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An improper handling of a malformed API request to an API server in Bosch BT software products can allow an unauthenticated attacker to cause a Denial of Service (DoS) situation."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-703",
"description": "CWE-703 Improper Check or Handling of Exceptional Conditions",
"lang": "en-US"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-18T12:58:08.690Z",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-092656-BT.html",
"tags": [
"vendor-advisory"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-092656-BT.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2023-32230",
"datePublished": "2023-12-18T12:58:08.690Z",
"dateReserved": "2023-05-04T21:01:16.508Z",
"dateUpdated": "2024-08-02T15:10:24.221Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-6786 (GCVE-0-2020-6786)
Vulnerability from cvelistv5 – Published: 2021-03-25 15:51 – Updated: 2024-09-16 17:38- CWE-427 - Uncontrolled Search Path Element
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Bosch | Video Recording Manager |
Affected:
3.71 and older all
Affected: 3.82 , ≤ 3.82.0055 (custom) Affected: 3.81 , ≤ 3.81.0064 (custom) |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:11:05.029Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://psirt.bosch.com/security-advisories/bosch-sa-835563-bt.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Video Recording Manager",
"vendor": "Bosch",
"versions": [
{
"status": "affected",
"version": "3.71 and older all"
},
{
"lessThanOrEqual": "3.82.0055",
"status": "affected",
"version": "3.82",
"versionType": "custom"
},
{
"lessThanOrEqual": "3.81.0064",
"status": "affected",
"version": "3.81",
"versionType": "custom"
}
]
}
],
"datePublic": "2021-03-24T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Loading a DLL through an Uncontrolled Search Path Element in the Bosch Video Recording Manager installer up to and including version 3.82.0055 for 3.82, up to and including version 3.81.0064 for 3.81 and 3.71 and older potentially allows an attacker to execute arbitrary code on a victim\u0027s system. A prerequisite is that the victim is tricked into placing a malicious DLL in the same directory where the installer is started from."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-427",
"description": "CWE-427 Uncontrolled Search Path Element",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-03-25T15:51:06",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://psirt.bosch.com/security-advisories/bosch-sa-835563-bt.html"
}
],
"source": {
"advisory": "BOSCH-SA-835563-BT",
"discovery": "INTERNAL"
},
"title": "Uncontrolled Search Path Element in Bosch Video Recording Manager Installer",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@bosch.com",
"DATE_PUBLIC": "2021-03-24",
"ID": "CVE-2020-6786",
"STATE": "PUBLIC",
"TITLE": "Uncontrolled Search Path Element in Bosch Video Recording Manager Installer"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Video Recording Manager",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "3.82",
"version_value": "3.82.0055"
},
{
"version_affected": "\u003c=",
"version_name": "3.81",
"version_value": "3.81.0064"
},
{
"version_affected": "=",
"version_name": "3.71 and older",
"version_value": "all"
}
]
}
}
]
},
"vendor_name": "Bosch"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Loading a DLL through an Uncontrolled Search Path Element in the Bosch Video Recording Manager installer up to and including version 3.82.0055 for 3.82, up to and including version 3.81.0064 for 3.81 and 3.71 and older potentially allows an attacker to execute arbitrary code on a victim\u0027s system. A prerequisite is that the victim is tricked into placing a malicious DLL in the same directory where the installer is started from."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-427 Uncontrolled Search Path Element"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://psirt.bosch.com/security-advisories/bosch-sa-835563-bt.html",
"refsource": "CONFIRM",
"url": "https://psirt.bosch.com/security-advisories/bosch-sa-835563-bt.html"
}
]
},
"source": {
"advisory": "BOSCH-SA-835563-BT",
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2020-6786",
"datePublished": "2021-03-25T15:51:06.153501Z",
"dateReserved": "2020-01-10T00:00:00",
"dateUpdated": "2024-09-16T17:38:51.758Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-32230 (GCVE-0-2023-32230)
Vulnerability from nvd – Published: 2023-12-18 12:58 – Updated: 2024-08-02 15:10- CWE-703 - Improper Check or Handling of Exceptional Conditions
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Bosch | Video Recording Manager |
Affected:
0 , ≤ 04.10.0079
(custom)
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T15:10:24.221Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-092656-BT.html",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-092656-BT.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Video Recording Manager",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "04.10.0079",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"product": "Video Streaming Gateway",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "8.1.2.2",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThanOrEqual": "9.0.0.178",
"status": "affected",
"version": "9.0.0",
"versionType": "custom"
}
]
},
{
"product": "Monitorwall",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "10.00.0164",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"product": "VJD-7513",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "10.40.0055",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"product": "VJD-7523",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "10.40.0055",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An improper handling of a malformed API request to an API server in Bosch BT software products can allow an unauthenticated attacker to cause a Denial of Service (DoS) situation."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-703",
"description": "CWE-703 Improper Check or Handling of Exceptional Conditions",
"lang": "en-US"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-18T12:58:08.690Z",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-092656-BT.html",
"tags": [
"vendor-advisory"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-092656-BT.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2023-32230",
"datePublished": "2023-12-18T12:58:08.690Z",
"dateReserved": "2023-05-04T21:01:16.508Z",
"dateUpdated": "2024-08-02T15:10:24.221Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-6786 (GCVE-0-2020-6786)
Vulnerability from nvd – Published: 2021-03-25 15:51 – Updated: 2024-09-16 17:38- CWE-427 - Uncontrolled Search Path Element
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Bosch | Video Recording Manager |
Affected:
3.71 and older all
Affected: 3.82 , ≤ 3.82.0055 (custom) Affected: 3.81 , ≤ 3.81.0064 (custom) |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:11:05.029Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://psirt.bosch.com/security-advisories/bosch-sa-835563-bt.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Video Recording Manager",
"vendor": "Bosch",
"versions": [
{
"status": "affected",
"version": "3.71 and older all"
},
{
"lessThanOrEqual": "3.82.0055",
"status": "affected",
"version": "3.82",
"versionType": "custom"
},
{
"lessThanOrEqual": "3.81.0064",
"status": "affected",
"version": "3.81",
"versionType": "custom"
}
]
}
],
"datePublic": "2021-03-24T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Loading a DLL through an Uncontrolled Search Path Element in the Bosch Video Recording Manager installer up to and including version 3.82.0055 for 3.82, up to and including version 3.81.0064 for 3.81 and 3.71 and older potentially allows an attacker to execute arbitrary code on a victim\u0027s system. A prerequisite is that the victim is tricked into placing a malicious DLL in the same directory where the installer is started from."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-427",
"description": "CWE-427 Uncontrolled Search Path Element",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-03-25T15:51:06",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://psirt.bosch.com/security-advisories/bosch-sa-835563-bt.html"
}
],
"source": {
"advisory": "BOSCH-SA-835563-BT",
"discovery": "INTERNAL"
},
"title": "Uncontrolled Search Path Element in Bosch Video Recording Manager Installer",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@bosch.com",
"DATE_PUBLIC": "2021-03-24",
"ID": "CVE-2020-6786",
"STATE": "PUBLIC",
"TITLE": "Uncontrolled Search Path Element in Bosch Video Recording Manager Installer"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Video Recording Manager",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "3.82",
"version_value": "3.82.0055"
},
{
"version_affected": "\u003c=",
"version_name": "3.81",
"version_value": "3.81.0064"
},
{
"version_affected": "=",
"version_name": "3.71 and older",
"version_value": "all"
}
]
}
}
]
},
"vendor_name": "Bosch"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Loading a DLL through an Uncontrolled Search Path Element in the Bosch Video Recording Manager installer up to and including version 3.82.0055 for 3.82, up to and including version 3.81.0064 for 3.81 and 3.71 and older potentially allows an attacker to execute arbitrary code on a victim\u0027s system. A prerequisite is that the victim is tricked into placing a malicious DLL in the same directory where the installer is started from."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-427 Uncontrolled Search Path Element"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://psirt.bosch.com/security-advisories/bosch-sa-835563-bt.html",
"refsource": "CONFIRM",
"url": "https://psirt.bosch.com/security-advisories/bosch-sa-835563-bt.html"
}
]
},
"source": {
"advisory": "BOSCH-SA-835563-BT",
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2020-6786",
"datePublished": "2021-03-25T15:51:06.153501Z",
"dateReserved": "2020-01-10T00:00:00",
"dateUpdated": "2024-09-16T17:38:51.758Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
VAR-201905-0314
Vulnerability from variot - Updated: 2023-12-18 12:18A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Video Recording Manager (VRM), Video Streaming Gateway (VSG), Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The vulnerability potentially allows the unauthorized execution of code in the system via the network interface. plural Bosch The product contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Bosch DIVAR IP 2000 and so on are all products of Bosch Company in Germany. Bosch DIVAR IP 2000 is a 2000 series video recorder. Video Recording Manager (VRM) is a video recording manager. Bosch DIVAR IP 3000 is a 3000 series video recorder. A buffer overflow vulnerability exists in several Bosch products. This vulnerability stems from the incorrect verification of data boundaries when the network system or product performs operations on the memory, resulting in incorrect read and write operations to other associated memory locations. Attackers can exploit this vulnerability to cause buffer overflow or heap overflow, etc
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201905-0314",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "building integration system",
"scope": "gte",
"trust": 1.0,
"vendor": "bosch",
"version": "2.2"
},
{
"model": "building integration system",
"scope": "eq",
"trust": 1.0,
"vendor": "bosch",
"version": "4.6"
},
{
"model": "building integration system",
"scope": "lte",
"trust": 1.0,
"vendor": "bosch",
"version": "4.4"
},
{
"model": "building integration system",
"scope": "eq",
"trust": 1.0,
"vendor": "bosch",
"version": "4.6.1"
},
{
"model": "video streaming gateway",
"scope": "gte",
"trust": 1.0,
"vendor": "bosch",
"version": "6.45"
},
{
"model": "video streaming gateway",
"scope": "lt",
"trust": 1.0,
"vendor": "bosch",
"version": "6.43.0023"
},
{
"model": "access easy controller",
"scope": "eq",
"trust": 1.0,
"vendor": "bosch",
"version": "2.1.8.5"
},
{
"model": "access easy controller",
"scope": "eq",
"trust": 1.0,
"vendor": "bosch",
"version": "2.1.9.1"
},
{
"model": "access easy controller",
"scope": "eq",
"trust": 1.0,
"vendor": "bosch",
"version": "2.1.9.0"
},
{
"model": "video recording manager",
"scope": "lt",
"trust": 1.0,
"vendor": "bosch",
"version": "3.81.0048"
},
{
"model": "access professional edition",
"scope": "gte",
"trust": 1.0,
"vendor": "bosch",
"version": "3.0"
},
{
"model": "access professional edition",
"scope": "lte",
"trust": 1.0,
"vendor": "bosch",
"version": "3.7"
},
{
"model": "access easy controller",
"scope": "eq",
"trust": 1.0,
"vendor": "bosch",
"version": "2.1.9.3"
},
{
"model": "video recording manager",
"scope": "gte",
"trust": 1.0,
"vendor": "bosch",
"version": "3.81"
},
{
"model": "video client",
"scope": "lt",
"trust": 1.0,
"vendor": "bosch",
"version": "1.7.6.079"
},
{
"model": "dip 5000",
"scope": "lt",
"trust": 1.0,
"vendor": "bosch",
"version": "038.037"
},
{
"model": "video management system",
"scope": "lte",
"trust": 1.0,
"vendor": "bosch",
"version": "9.0"
},
{
"model": "dip 2000",
"scope": "lt",
"trust": 1.0,
"vendor": "bosch",
"version": "0380.037"
},
{
"model": "video recording manager",
"scope": "lt",
"trust": 1.0,
"vendor": "bosch",
"version": "3.71.0032"
},
{
"model": "dip 7000",
"scope": "eq",
"trust": 1.0,
"vendor": "bosch",
"version": null
},
{
"model": "dip 3000",
"scope": "eq",
"trust": 1.0,
"vendor": "bosch",
"version": null
},
{
"model": "video sdk",
"scope": "lt",
"trust": 1.0,
"vendor": "bosch",
"version": "6.32.0099"
},
{
"model": "configuration manager",
"scope": "lt",
"trust": 1.0,
"vendor": "bosch",
"version": "6.10"
},
{
"model": "video streaming gateway",
"scope": "lt",
"trust": 1.0,
"vendor": "bosch",
"version": "6.45.0008"
},
{
"model": "building integration system",
"scope": "eq",
"trust": 1.0,
"vendor": "bosch",
"version": "4.5"
},
{
"model": "access easy controller",
"scope": null,
"trust": 0.8,
"vendor": "robert bosch",
"version": null
},
{
"model": "access professional edition",
"scope": null,
"trust": 0.8,
"vendor": "robert bosch",
"version": null
},
{
"model": "video client",
"scope": null,
"trust": 0.8,
"vendor": "robert bosch",
"version": null
},
{
"model": "video management system",
"scope": null,
"trust": 0.8,
"vendor": "robert bosch",
"version": null
},
{
"model": "building integration system",
"scope": null,
"trust": 0.8,
"vendor": "robert bosch",
"version": null
},
{
"model": "configuration manager",
"scope": null,
"trust": 0.8,
"vendor": "robert bosch",
"version": null
},
{
"model": "divar ip 3000",
"scope": null,
"trust": 0.8,
"vendor": "robert bosch",
"version": null
},
{
"model": "divar ip 7000",
"scope": null,
"trust": 0.8,
"vendor": "robert bosch",
"version": null
},
{
"model": "video sdk",
"scope": null,
"trust": 0.8,
"vendor": "robert bosch",
"version": null
},
{
"model": "video streaming gateway",
"scope": null,
"trust": 0.8,
"vendor": "robert bosch",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-004953"
},
{
"db": "NVD",
"id": "CVE-2019-6957"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:bosch:video_recording_manager:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "3.71.0032",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:bosch:bosch_video_management_system:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "9.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:bosch:access_professional_edition:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "3.7",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:bosch:building_integration_system:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "4.4",
"versionStartIncluding": "2.2",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:bosch:building_integration_system:4.5:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:bosch:building_integration_system:4.6:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:bosch:building_integration_system:4.6.1:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:bosch:bosch_video_client:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.7.6.079",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:bosch:video_sdk:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "6.32.0099",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:bosch:configuration_manager:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "6.10",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:bosch:video_streaming_gateway:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "6.43.0023",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:bosch:video_streaming_gateway:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "6.45.0008",
"versionStartIncluding": "6.45",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:bosch:video_recording_manager:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "3.81.0048",
"versionStartIncluding": "3.81",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:bosch:dip_2000_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "0380.037",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:bosch:dip_2000:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:bosch:dip_3000_firmware:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:bosch:dip_3000:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:bosch:dip_5000_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "038.037",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:bosch:dip_5000:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:bosch:dip_7000_firmware:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:bosch:dip_7000:gen1:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:bosch:dip_7000:gen2:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:bosch:access_easy_controller_firmware:2.1.8.5:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:bosch:access_easy_controller_firmware:2.1.9.3:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:bosch:access_easy_controller_firmware:2.1.9.1:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:bosch:access_easy_controller_firmware:2.1.9.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:bosch:access_easy_controller:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2019-6957"
}
]
},
"cve": "CVE-2019-6957",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 7.5,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2019-6957",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.9,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "VHN-158392",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "cve@mitre.org",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2019-6957",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2019-6957",
"trust": 1.8,
"value": "CRITICAL"
},
{
"author": "cve@mitre.org",
"id": "CVE-2019-6957",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "CNNVD",
"id": "CNNVD-201905-1062",
"trust": 0.6,
"value": "CRITICAL"
},
{
"author": "VULHUB",
"id": "VHN-158392",
"trust": 0.1,
"value": "HIGH"
},
{
"author": "VULMON",
"id": "CVE-2019-6957",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-158392"
},
{
"db": "VULMON",
"id": "CVE-2019-6957"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-004953"
},
{
"db": "NVD",
"id": "CVE-2019-6957"
},
{
"db": "NVD",
"id": "CVE-2019-6957"
},
{
"db": "CNNVD",
"id": "CNNVD-201905-1062"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Video Recording Manager (VRM), Video Streaming Gateway (VSG), Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The vulnerability potentially allows the unauthorized execution of code in the system via the network interface. plural Bosch The product contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Bosch DIVAR IP 2000 and so on are all products of Bosch Company in Germany. Bosch DIVAR IP 2000 is a 2000 series video recorder. Video Recording Manager (VRM) is a video recording manager. Bosch DIVAR IP 3000 is a 3000 series video recorder. A buffer overflow vulnerability exists in several Bosch products. This vulnerability stems from the incorrect verification of data boundaries when the network system or product performs operations on the memory, resulting in incorrect read and write operations to other associated memory locations. Attackers can exploit this vulnerability to cause buffer overflow or heap overflow, etc",
"sources": [
{
"db": "NVD",
"id": "CVE-2019-6957"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-004953"
},
{
"db": "VULHUB",
"id": "VHN-158392"
},
{
"db": "VULMON",
"id": "CVE-2019-6957"
}
],
"trust": 1.8
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2019-6957",
"trust": 2.6
},
{
"db": "JVNDB",
"id": "JVNDB-2019-004953",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201905-1062",
"trust": 0.7
},
{
"db": "VULHUB",
"id": "VHN-158392",
"trust": 0.1
},
{
"db": "VULMON",
"id": "CVE-2019-6957",
"trust": 0.1
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-158392"
},
{
"db": "VULMON",
"id": "CVE-2019-6957"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-004953"
},
{
"db": "NVD",
"id": "CVE-2019-6957"
},
{
"db": "CNNVD",
"id": "CNNVD-201905-1062"
}
]
},
"id": "VAR-201905-0314",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VULHUB",
"id": "VHN-158392"
}
],
"trust": 0.01
},
"last_update_date": "2023-12-18T12:18:04.045000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "BOSCH-2019-0403-BT",
"trust": 0.8,
"url": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0403bt-cve-2019-6957_security_advisory_software_buffer_overflow.pdf"
},
{
"title": "Multiple Bosch Product Buffer Error Vulnerability Fix",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=93015"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-004953"
},
{
"db": "CNNVD",
"id": "CNNVD-201905-1062"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.1
},
{
"problemtype": "CWE-119",
"trust": 0.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-158392"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-004953"
},
{
"db": "NVD",
"id": "CVE-2019-6957"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0403bt-cve-2019-6957_security_advisory_software_buffer_overflow.pdf"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2019-6957"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-6957"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/787.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-158392"
},
{
"db": "VULMON",
"id": "CVE-2019-6957"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-004953"
},
{
"db": "NVD",
"id": "CVE-2019-6957"
},
{
"db": "CNNVD",
"id": "CNNVD-201905-1062"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULHUB",
"id": "VHN-158392"
},
{
"db": "VULMON",
"id": "CVE-2019-6957"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-004953"
},
{
"db": "NVD",
"id": "CVE-2019-6957"
},
{
"db": "CNNVD",
"id": "CNNVD-201905-1062"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-05-29T00:00:00",
"db": "VULHUB",
"id": "VHN-158392"
},
{
"date": "2019-05-29T00:00:00",
"db": "VULMON",
"id": "CVE-2019-6957"
},
{
"date": "2019-06-12T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-004953"
},
{
"date": "2019-05-29T19:29:00.657000",
"db": "NVD",
"id": "CVE-2019-6957"
},
{
"date": "2019-05-29T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201905-1062"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-11-30T00:00:00",
"db": "VULHUB",
"id": "VHN-158392"
},
{
"date": "2022-11-30T00:00:00",
"db": "VULMON",
"id": "CVE-2019-6957"
},
{
"date": "2019-06-12T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-004953"
},
{
"date": "2022-11-30T21:46:59.810000",
"db": "NVD",
"id": "CVE-2019-6957"
},
{
"date": "2020-08-25T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201905-1062"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201905-1062"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural Bosch Product buffer error vulnerability",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-004953"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201905-1062"
}
],
"trust": 0.6
}
}