Search criteria
2 vulnerabilities found for VideoEdge by Sensormatic Electronics, a subsidiary of Johnson Controls, Inc.
CVE-2023-3749 (GCVE-0-2023-3749)
Vulnerability from cvelistv5 – Published: 2023-08-03 19:40 – Updated: 2024-10-09 20:11
VLAI?
Title
VideoEdge config
Summary
A local user could edit the VideoEdge configuration file and interfere with VideoEdge operation.
Severity ?
7.1 (High)
CWE
- CWE-349 - Acceptance of Extraneous Untrusted Data With Trusted Data
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Sensormatic Electronics, a subsidiary of Johnson Controls, Inc. | VideoEdge |
Affected:
0 , < 6.1.1
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T07:01:57.633Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.johnsoncontrols.com/cyber-solutions/security-advisories"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-215-04"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-3749",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-09T19:35:44.210466Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-09T20:11:19.294Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "VideoEdge",
"vendor": "Sensormatic Electronics, a subsidiary of Johnson Controls, Inc.",
"versions": [
{
"lessThan": "6.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"datePublic": "2023-08-03T19:33:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A local user could edit the VideoEdge configuration file and interfere with VideoEdge operation."
}
],
"value": "A local user could edit the VideoEdge configuration file and interfere with VideoEdge operation."
}
],
"impacts": [
{
"capecId": "CAPEC-153",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-153 Input Data Manipulation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-349",
"description": "CWE-349 Acceptance of Extraneous Untrusted Data With Trusted Data",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T19:40:05.497Z",
"orgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
"shortName": "jci"
},
"references": [
{
"url": "https://www.johnsoncontrols.com/cyber-solutions/security-advisories"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-215-04"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update VideoEdge to version 6.1.1.\u003cbr\u003eThe update can be downloaded from \u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://www.americandynamics.net\"\u003ewww.americandynamics.net\u003c/a\u003e under Support/Software Downloads/Network Video Recorders.\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "Update VideoEdge to version 6.1.1.\nThe update can be downloaded from www.americandynamics.net http://www.americandynamics.net under Support/Software Downloads/Network Video Recorders.\n\n"
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "VideoEdge config",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
"assignerShortName": "jci",
"cveId": "CVE-2023-3749",
"datePublished": "2023-08-03T19:40:05.497Z",
"dateReserved": "2023-07-18T14:49:50.889Z",
"dateUpdated": "2024-10-09T20:11:19.294Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-3749 (GCVE-0-2023-3749)
Vulnerability from nvd – Published: 2023-08-03 19:40 – Updated: 2024-10-09 20:11
VLAI?
Title
VideoEdge config
Summary
A local user could edit the VideoEdge configuration file and interfere with VideoEdge operation.
Severity ?
7.1 (High)
CWE
- CWE-349 - Acceptance of Extraneous Untrusted Data With Trusted Data
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Sensormatic Electronics, a subsidiary of Johnson Controls, Inc. | VideoEdge |
Affected:
0 , < 6.1.1
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T07:01:57.633Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.johnsoncontrols.com/cyber-solutions/security-advisories"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-215-04"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-3749",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-09T19:35:44.210466Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-09T20:11:19.294Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "VideoEdge",
"vendor": "Sensormatic Electronics, a subsidiary of Johnson Controls, Inc.",
"versions": [
{
"lessThan": "6.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"datePublic": "2023-08-03T19:33:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A local user could edit the VideoEdge configuration file and interfere with VideoEdge operation."
}
],
"value": "A local user could edit the VideoEdge configuration file and interfere with VideoEdge operation."
}
],
"impacts": [
{
"capecId": "CAPEC-153",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-153 Input Data Manipulation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-349",
"description": "CWE-349 Acceptance of Extraneous Untrusted Data With Trusted Data",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T19:40:05.497Z",
"orgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
"shortName": "jci"
},
"references": [
{
"url": "https://www.johnsoncontrols.com/cyber-solutions/security-advisories"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-215-04"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update VideoEdge to version 6.1.1.\u003cbr\u003eThe update can be downloaded from \u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://www.americandynamics.net\"\u003ewww.americandynamics.net\u003c/a\u003e under Support/Software Downloads/Network Video Recorders.\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "Update VideoEdge to version 6.1.1.\nThe update can be downloaded from www.americandynamics.net http://www.americandynamics.net under Support/Software Downloads/Network Video Recorders.\n\n"
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "VideoEdge config",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
"assignerShortName": "jci",
"cveId": "CVE-2023-3749",
"datePublished": "2023-08-03T19:40:05.497Z",
"dateReserved": "2023-07-18T14:49:50.889Z",
"dateUpdated": "2024-10-09T20:11:19.294Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}