VAR-201810-0478
Vulnerability from variot - Updated: 2023-12-18 13:13Carestream Vue RIS, RIS Client Builds: Version 11.2 and prior running on a Windows 8.1 machine with IIS/7.5. When contacting a Carestream server where there is no Oracle TNS listener available, users will trigger an HTTP 500 error, leaking technical information an attacker could use to initiate a more elaborate attack. Carestream Vue RIS Contains an information disclosure vulnerability.Information may be obtained. An attacker could exploit this vulnerability to obtain technical information
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201810-0478",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "vue ris",
"scope": "lte",
"trust": 1.0,
"vendor": "carestream",
"version": "11.2"
},
{
"model": "vue ris",
"scope": "eq",
"trust": 0.9,
"vendor": "carestream",
"version": "11.2"
},
{
"model": "vue ris",
"scope": "lte",
"trust": 0.8,
"vendor": "carestream",
"version": "ris client builds 11.2"
},
{
"model": "vue ris",
"scope": "lte",
"trust": 0.6,
"vendor": "carestream",
"version": "\u003c=11.2"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "carestream vue ris",
"version": "*"
}
],
"sources": [
{
"db": "IVD",
"id": "7d856950-463f-11e9-bb98-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2018-21171"
},
{
"db": "BID",
"id": "105713"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-010568"
},
{
"db": "NVD",
"id": "CVE-2018-17891"
},
{
"db": "CNNVD",
"id": "CNNVD-201810-156"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:carestream:carestream_vue_ris:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "11.2",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:microsoft:windows_8.1:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2018-17891"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Dan Regalado of Zingbox",
"sources": [
{
"db": "BID",
"id": "105713"
}
],
"trust": 0.3
},
"cve": "CVE-2018-17891",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.6,
"impactScore": 2.9,
"integrityImpact": "NONE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Medium",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 4.3,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2018-17891",
"impactScore": null,
"integrityImpact": "None",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"accessComplexity": "HIGH",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "NONE",
"baseScore": 2.6,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 4.9,
"id": "CNVD-2018-21171",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "LOW",
"trust": 0.6,
"vectorString": "AV:N/AC:H/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"accessComplexity": "HIGH",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "NONE",
"baseScore": 2.6,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 4.9,
"id": "7d856950-463f-11e9-bb98-000c29342cb1",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "LOW",
"trust": 0.2,
"vectorString": "AV:N/AC:H/Au:N/C:P/I:N/A:N",
"version": "2.9 [IVD]"
}
],
"cvssV3": [
{
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 3.7,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"exploitabilityScore": 2.2,
"impactScore": 1.4,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.0"
},
{
"attackComplexity": "High",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 3.7,
"baseSeverity": "Low",
"confidentialityImpact": "Low",
"exploitabilityScore": null,
"id": "CVE-2018-17891",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2018-17891",
"trust": 1.8,
"value": "LOW"
},
{
"author": "CNVD",
"id": "CNVD-2018-21171",
"trust": 0.6,
"value": "LOW"
},
{
"author": "CNNVD",
"id": "CNNVD-201810-156",
"trust": 0.6,
"value": "LOW"
},
{
"author": "IVD",
"id": "7d856950-463f-11e9-bb98-000c29342cb1",
"trust": 0.2,
"value": "LOW"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "7d856950-463f-11e9-bb98-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2018-21171"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-010568"
},
{
"db": "NVD",
"id": "CVE-2018-17891"
},
{
"db": "CNNVD",
"id": "CNNVD-201810-156"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Carestream Vue RIS, RIS Client Builds: Version 11.2 and prior running on a Windows 8.1 machine with IIS/7.5. When contacting a Carestream server where there is no Oracle TNS listener available, users will trigger an HTTP 500 error, leaking technical information an attacker could use to initiate a more elaborate attack. Carestream Vue RIS Contains an information disclosure vulnerability.Information may be obtained. An attacker could exploit this vulnerability to obtain technical information",
"sources": [
{
"db": "NVD",
"id": "CVE-2018-17891"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-010568"
},
{
"db": "CNVD",
"id": "CNVD-2018-21171"
},
{
"db": "BID",
"id": "105713"
},
{
"db": "IVD",
"id": "7d856950-463f-11e9-bb98-000c29342cb1"
}
],
"trust": 2.61
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2018-17891",
"trust": 3.5
},
{
"db": "ICS CERT",
"id": "ICSMA-18-277-01",
"trust": 2.7
},
{
"db": "CNVD",
"id": "CNVD-2018-21171",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201810-156",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2018-010568",
"trust": 0.8
},
{
"db": "BID",
"id": "105713",
"trust": 0.3
},
{
"db": "IVD",
"id": "7D856950-463F-11E9-BB98-000C29342CB1",
"trust": 0.2
}
],
"sources": [
{
"db": "IVD",
"id": "7d856950-463f-11e9-bb98-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2018-21171"
},
{
"db": "BID",
"id": "105713"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-010568"
},
{
"db": "NVD",
"id": "CVE-2018-17891"
},
{
"db": "CNNVD",
"id": "CNNVD-201810-156"
}
]
},
"id": "VAR-201810-0478",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "7d856950-463f-11e9-bb98-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2018-21171"
}
],
"trust": 1.4
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.8
}
],
"sources": [
{
"db": "IVD",
"id": "7d856950-463f-11e9-bb98-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2018-21171"
}
]
},
"last_update_date": "2023-12-18T13:13:39.900000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "CARESTREAM Vue RIS",
"trust": 0.8,
"url": "https://www.carestream.com/en/us/medical/products/vue-healthit/radiology/carestream-vue-ris"
},
{
"title": "Patch for Carestream Vue RIS Information Disclosure Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/142569"
},
{
"title": "Carestream Vue RIS Security vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=86164"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-21171"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-010568"
},
{
"db": "CNNVD",
"id": "CNNVD-201810-156"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-200",
"trust": 1.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-010568"
},
{
"db": "NVD",
"id": "CVE-2018-17891"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.7,
"url": "https://ics-cert.us-cert.gov/advisories/icsma-18-277-01"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2018-17891"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-17891"
},
{
"trust": 0.3,
"url": "https://www.carestream.com"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-21171"
},
{
"db": "BID",
"id": "105713"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-010568"
},
{
"db": "NVD",
"id": "CVE-2018-17891"
},
{
"db": "CNNVD",
"id": "CNNVD-201810-156"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "7d856950-463f-11e9-bb98-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2018-21171"
},
{
"db": "BID",
"id": "105713"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-010568"
},
{
"db": "NVD",
"id": "CVE-2018-17891"
},
{
"db": "CNNVD",
"id": "CNNVD-201810-156"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2018-10-18T00:00:00",
"db": "IVD",
"id": "7d856950-463f-11e9-bb98-000c29342cb1"
},
{
"date": "2018-10-17T00:00:00",
"db": "CNVD",
"id": "CNVD-2018-21171"
},
{
"date": "2018-10-04T00:00:00",
"db": "BID",
"id": "105713"
},
{
"date": "2018-12-18T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-010568"
},
{
"date": "2018-10-04T21:29:01.983000",
"db": "NVD",
"id": "CVE-2018-17891"
},
{
"date": "2018-10-08T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201810-156"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-11-01T00:00:00",
"db": "CNVD",
"id": "CNVD-2018-21171"
},
{
"date": "2018-10-04T00:00:00",
"db": "BID",
"id": "105713"
},
{
"date": "2018-12-18T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-010568"
},
{
"date": "2019-10-09T23:37:00.050000",
"db": "NVD",
"id": "CVE-2018-17891"
},
{
"date": "2019-10-17T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201810-156"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201810-156"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Carestream Vue RIS Information Disclosure Vulnerability",
"sources": [
{
"db": "IVD",
"id": "7d856950-463f-11e9-bb98-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2018-21171"
},
{
"db": "CNNVD",
"id": "CNNVD-201810-156"
}
],
"trust": 1.4
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "information disclosure",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201810-156"
}
],
"trust": 0.6
}
}
CVE-2018-17891 (GCVE-0-2018-17891)
Vulnerability from cvelistv5 – Published: 2018-10-04 21:00 – Updated: 2024-09-17 02:32
VLAI?
Summary
Carestream Vue RIS, RIS Client Builds: Version 11.2 and prior running on a Windows 8.1 machine with IIS/7.5. When contacting a Carestream server where there is no Oracle TNS listener available, users will trigger an HTTP 500 error, leaking technical information an attacker could use to initiate a more elaborate attack.
Severity ?
No CVSS data available.
CWE
- CWE-209 - INFORMATION EXPOSURE THROUGH AN ERROR MESSAGE CWE-209
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Carestream | Vue RIS |
Affected:
RIS Client Builds: Version 11.2 and prior running on a Windows 8.1 machine with IIS/7.5
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T11:01:14.459Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-277-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Vue RIS",
"vendor": "Carestream",
"versions": [
{
"status": "affected",
"version": "RIS Client Builds: Version 11.2 and prior running on a Windows 8.1 machine with IIS/7.5"
}
]
}
],
"datePublic": "2018-10-04T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Carestream Vue RIS, RIS Client Builds: Version 11.2 and prior running on a Windows 8.1 machine with IIS/7.5. When contacting a Carestream server where there is no Oracle TNS listener available, users will trigger an HTTP 500 error, leaking technical information an attacker could use to initiate a more elaborate attack."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-209",
"description": "INFORMATION EXPOSURE THROUGH AN ERROR MESSAGE CWE-209",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-10-04T20:57:01",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-277-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2018-10-04T00:00:00",
"ID": "CVE-2018-17891",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Vue RIS",
"version": {
"version_data": [
{
"version_value": "RIS Client Builds: Version 11.2 and prior running on a Windows 8.1 machine with IIS/7.5"
}
]
}
}
]
},
"vendor_name": "Carestream"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Carestream Vue RIS, RIS Client Builds: Version 11.2 and prior running on a Windows 8.1 machine with IIS/7.5. When contacting a Carestream server where there is no Oracle TNS listener available, users will trigger an HTTP 500 error, leaking technical information an attacker could use to initiate a more elaborate attack."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "INFORMATION EXPOSURE THROUGH AN ERROR MESSAGE CWE-209"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-277-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-277-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2018-17891",
"datePublished": "2018-10-04T21:00:00Z",
"dateReserved": "2018-10-02T00:00:00",
"dateUpdated": "2024-09-17T02:32:31.321Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-17891 (GCVE-0-2018-17891)
Vulnerability from nvd – Published: 2018-10-04 21:00 – Updated: 2024-09-17 02:32
VLAI?
Summary
Carestream Vue RIS, RIS Client Builds: Version 11.2 and prior running on a Windows 8.1 machine with IIS/7.5. When contacting a Carestream server where there is no Oracle TNS listener available, users will trigger an HTTP 500 error, leaking technical information an attacker could use to initiate a more elaborate attack.
Severity ?
No CVSS data available.
CWE
- CWE-209 - INFORMATION EXPOSURE THROUGH AN ERROR MESSAGE CWE-209
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Carestream | Vue RIS |
Affected:
RIS Client Builds: Version 11.2 and prior running on a Windows 8.1 machine with IIS/7.5
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T11:01:14.459Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-277-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Vue RIS",
"vendor": "Carestream",
"versions": [
{
"status": "affected",
"version": "RIS Client Builds: Version 11.2 and prior running on a Windows 8.1 machine with IIS/7.5"
}
]
}
],
"datePublic": "2018-10-04T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Carestream Vue RIS, RIS Client Builds: Version 11.2 and prior running on a Windows 8.1 machine with IIS/7.5. When contacting a Carestream server where there is no Oracle TNS listener available, users will trigger an HTTP 500 error, leaking technical information an attacker could use to initiate a more elaborate attack."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-209",
"description": "INFORMATION EXPOSURE THROUGH AN ERROR MESSAGE CWE-209",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-10-04T20:57:01",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-277-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2018-10-04T00:00:00",
"ID": "CVE-2018-17891",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Vue RIS",
"version": {
"version_data": [
{
"version_value": "RIS Client Builds: Version 11.2 and prior running on a Windows 8.1 machine with IIS/7.5"
}
]
}
}
]
},
"vendor_name": "Carestream"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Carestream Vue RIS, RIS Client Builds: Version 11.2 and prior running on a Windows 8.1 machine with IIS/7.5. When contacting a Carestream server where there is no Oracle TNS listener available, users will trigger an HTTP 500 error, leaking technical information an attacker could use to initiate a more elaborate attack."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "INFORMATION EXPOSURE THROUGH AN ERROR MESSAGE CWE-209"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-277-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-277-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2018-17891",
"datePublished": "2018-10-04T21:00:00Z",
"dateReserved": "2018-10-02T00:00:00",
"dateUpdated": "2024-09-17T02:32:31.321Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}