Search criteria
6 vulnerabilities found for WC9500 by NETGEAR
VAR-202010-0588
Vulnerability from variot - Updated: 2023-12-18 14:04Certain NETGEAR devices are affected by command injection by an authenticated user. This affects WC7500 before 6.5.5.24, WC7600 before 6.5.5.24, WC7600v2 before 6.5.5.24, and WC9500 before 6.5.5.24. plural NETGEAR The product contains a command injection vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202010-0588",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "wc9500",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "6.5.5.24"
},
{
"model": "wc7500",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "6.5.5.24"
},
{
"model": "wc7600v2",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "6.5.5.24"
},
{
"model": "wc7600",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "6.5.5.24"
},
{
"model": "wc7500",
"scope": null,
"trust": 0.8,
"vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
"version": null
},
{
"model": "wc7600v2",
"scope": null,
"trust": 0.8,
"vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
"version": null
},
{
"model": "wc7600",
"scope": null,
"trust": 0.8,
"vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
"version": null
},
{
"model": "wc9500",
"scope": null,
"trust": 0.8,
"vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-012118"
},
{
"db": "NVD",
"id": "CVE-2020-26922"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:netgear:wc7500_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "6.5.5.24",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:netgear:wc7500:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:netgear:wc7600_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "6.5.5.24",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:netgear:wc7600:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:netgear:wc7600v2_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "6.5.5.24",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:netgear:wc7600v2:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:netgear:wc9500_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "6.5.5.24",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:netgear:wc9500:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2020-26922"
}
]
},
"cve": "CVE-2020-26922",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 4.6,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 3.9,
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Local",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 4.6,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2020-26922",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 0.8,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"author": "cve@mitre.org",
"availabilityImpact": "HIGH",
"baseScore": 6.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 0.5,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Local",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 6.7,
"baseSeverity": "Medium",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2020-26922",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "High",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2020-26922",
"trust": 1.8,
"value": "MEDIUM"
},
{
"author": "cve@mitre.org",
"id": "CVE-2020-26922",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-202010-354",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-012118"
},
{
"db": "NVD",
"id": "CVE-2020-26922"
},
{
"db": "NVD",
"id": "CVE-2020-26922"
},
{
"db": "CNNVD",
"id": "CNNVD-202010-354"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects WC7500 before 6.5.5.24, WC7600 before 6.5.5.24, WC7600v2 before 6.5.5.24, and WC9500 before 6.5.5.24. plural NETGEAR The product contains a command injection vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2020-26922"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-012118"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2020-26922",
"trust": 2.4
},
{
"db": "JVNDB",
"id": "JVNDB-2020-012118",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-202010-354",
"trust": 0.6
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-012118"
},
{
"db": "NVD",
"id": "CVE-2020-26922"
},
{
"db": "CNNVD",
"id": "CNNVD-202010-354"
}
]
},
"id": "VAR-202010-0588",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.29270833
},
"last_update_date": "2023-12-18T14:04:34.013000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0Wireless\u00a0Controllers,\u00a0PSV-2020-0139",
"trust": 0.8,
"url": "https://kb.netgear.com/000062330/security-advisory-for-post-authentication-command-injection-on-some-wireless-controllers-psv-2020-0139"
},
{
"title": "Multiple NETGEAR Fixes for device command injection vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=131140"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-012118"
},
{
"db": "CNNVD",
"id": "CNNVD-202010-354"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-77",
"trust": 1.0
},
{
"problemtype": "Command injection (CWE-77) [NVD Evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-012118"
},
{
"db": "NVD",
"id": "CVE-2020-26922"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.6,
"url": "https://kb.netgear.com/000062330/security-advisory-for-post-authentication-command-injection-on-some-wireless-controllers-psv-2020-0139"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2020-26922"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-012118"
},
{
"db": "NVD",
"id": "CVE-2020-26922"
},
{
"db": "CNNVD",
"id": "CNNVD-202010-354"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2020-012118"
},
{
"db": "NVD",
"id": "CVE-2020-26922"
},
{
"db": "CNNVD",
"id": "CNNVD-202010-354"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-04-26T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2020-012118"
},
{
"date": "2020-10-09T07:15:17.857000",
"db": "NVD",
"id": "CVE-2020-26922"
},
{
"date": "2020-10-09T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202010-354"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-04-26T03:13:00",
"db": "JVNDB",
"id": "JVNDB-2020-012118"
},
{
"date": "2020-10-15T20:02:42.890000",
"db": "NVD",
"id": "CVE-2020-26922"
},
{
"date": "2020-10-21T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202010-354"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "local",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202010-354"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerabilities in the product",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-012118"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "command injection",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202010-354"
}
],
"trust": 0.6
}
}
VAR-202004-1520
Vulnerability from variot - Updated: 2023-12-18 13:56NETGEAR has released fixes for a pre-authentication command injection in request_handler.php security vulnerability on the following product models: WC7500, running firmware versions prior to 6.5.3.5; WC7520, running firmware versions prior to 2.5.0.46; WC7600v1, running firmware versions prior to 6.5.3.5; WC7600v2, running firmware versions prior to 6.5.3.5; and WC9500, running firmware versions prior to 6.5.3.5. plural NETGEAR The product contains an injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR WC7500 is a wireless LAN controller of NETGEAR.
There are injection holes in the request_handler.php file in many NETGEAR products. A remote attacker can use the vulnerability to execute arbitrary commands by sending a specially crafted request
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202004-1520",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "wc7520",
"scope": "lt",
"trust": 1.6,
"vendor": "netgear",
"version": "2.5.0.46"
},
{
"model": "wc9500",
"scope": "lt",
"trust": 1.6,
"vendor": "netgear",
"version": "6.5.3.5"
},
{
"model": "wc7600v2",
"scope": "lt",
"trust": 1.6,
"vendor": "netgear",
"version": "6.5.3.5"
},
{
"model": "wc7600v1",
"scope": "lt",
"trust": 1.6,
"vendor": "netgear",
"version": "6.5.3.5"
},
{
"model": "wc7500",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "6.5.3.5"
},
{
"model": "wc7500",
"scope": "eq",
"trust": 0.8,
"vendor": "netgear",
"version": "6.5.3.5"
},
{
"model": "wc7520",
"scope": "eq",
"trust": 0.8,
"vendor": "netgear",
"version": "2.5.0.46"
},
{
"model": "wc7600v1",
"scope": "eq",
"trust": 0.8,
"vendor": "netgear",
"version": "6.5.3.5"
},
{
"model": "wc7600v2",
"scope": "eq",
"trust": 0.8,
"vendor": "netgear",
"version": "6.5.3.5"
},
{
"model": "wc9500",
"scope": "eq",
"trust": 0.8,
"vendor": "netgear",
"version": "6.5.3.5"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-35517"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-016279"
},
{
"db": "NVD",
"id": "CVE-2018-11106"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:netgear:wc7500_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "6.5.3.5",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:netgear:wc7500:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:netgear:wc7520_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "2.5.0.46",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:netgear:wc7520:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:netgear:wc7600v1_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "6.5.3.5",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:netgear:wc7600v1:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:netgear:wc7600v2_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "6.5.3.5",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:netgear:wc7600v2:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:netgear:wc9500_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "6.5.3.5",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:netgear:wc9500:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2018-11106"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Alexander Oleinik (alxndr on Bugcrowd) , Steven So , Muhammad Anas Imtiaz , Daniel Finn , Manuel Egele",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202004-019"
}
],
"trust": 0.6
},
"cve": "CVE-2018-11106",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Complete",
"baseScore": 10.0,
"confidentialityImpact": "Complete",
"exploitabilityScore": null,
"id": "JVNDB-2018-016279",
"impactScore": null,
"integrityImpact": "Complete",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2020-35517",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2018-016279",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2018-11106",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "JVNDB-2018-016279",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2020-35517",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202004-019",
"trust": 0.6,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-35517"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-016279"
},
{
"db": "NVD",
"id": "CVE-2018-11106"
},
{
"db": "CNNVD",
"id": "CNNVD-202004-019"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "NETGEAR has released fixes for a pre-authentication command injection in request_handler.php security vulnerability on the following product models: WC7500, running firmware versions prior to 6.5.3.5; WC7520, running firmware versions prior to 2.5.0.46; WC7600v1, running firmware versions prior to 6.5.3.5; WC7600v2, running firmware versions prior to 6.5.3.5; and WC9500, running firmware versions prior to 6.5.3.5. plural NETGEAR The product contains an injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR WC7500 is a wireless LAN controller of NETGEAR. \n\r\n\r\nThere are injection holes in the request_handler.php file in many NETGEAR products. A remote attacker can use the vulnerability to execute arbitrary commands by sending a specially crafted request",
"sources": [
{
"db": "NVD",
"id": "CVE-2018-11106"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-016279"
},
{
"db": "CNVD",
"id": "CNVD-2020-35517"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2018-11106",
"trust": 3.0
},
{
"db": "JVNDB",
"id": "JVNDB-2018-016279",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2020-35517",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202004-019",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-35517"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-016279"
},
{
"db": "NVD",
"id": "CVE-2018-11106"
},
{
"db": "CNNVD",
"id": "CNNVD-202004-019"
}
]
},
"id": "VAR-202004-1520",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-35517"
}
],
"trust": 1.070357144
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-35517"
}
]
},
"last_update_date": "2023-12-18T13:56:18.854000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Security Advisory for Pre-Authentication Command Injection in request_handler.php on Some Wireless Controllers, PSV-2018-0051",
"trust": 0.8,
"url": "https://kb.netgear.com/000058243/security-advisory-for-pre-authentication-command-injection-in-request-handler-php-on-some-wireless-controllers-psv-2018-0051"
},
{
"title": "Patch for Multiple NETGEAR product command injection vulnerabilities (CNVD-2020-35517)",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/224055"
},
{
"title": "Multiple NETGEAR Fixing measures for product injection vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=117072"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-35517"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-016279"
},
{
"db": "CNNVD",
"id": "CNNVD-202004-019"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-77",
"trust": 1.0
},
{
"problemtype": "CWE-74",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-016279"
},
{
"db": "NVD",
"id": "CVE-2018-11106"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.0,
"url": "https://nvd.nist.gov/vuln/detail/cve-2018-11106"
},
{
"trust": 1.6,
"url": "https://kb.netgear.com/000058243/security-advisory-for-pre-authentication-command-injection-in-request-handler-php-on-some-wireless-controllers-psv-2018-0051"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-11106"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-35517"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-016279"
},
{
"db": "NVD",
"id": "CVE-2018-11106"
},
{
"db": "CNNVD",
"id": "CNNVD-202004-019"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2020-35517"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-016279"
},
{
"db": "NVD",
"id": "CVE-2018-11106"
},
{
"db": "CNNVD",
"id": "CNNVD-202004-019"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-07-01T00:00:00",
"db": "CNVD",
"id": "CNVD-2020-35517"
},
{
"date": "2020-04-30T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-016279"
},
{
"date": "2020-04-01T17:15:14.737000",
"db": "NVD",
"id": "CVE-2018-11106"
},
{
"date": "2020-04-01T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202004-019"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-07-01T00:00:00",
"db": "CNVD",
"id": "CNVD-2020-35517"
},
{
"date": "2020-04-30T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-016279"
},
{
"date": "2023-11-07T02:51:37.613000",
"db": "NVD",
"id": "CVE-2018-11106"
},
{
"date": "2022-03-18T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202004-019"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202004-019"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural NETGEAR Product injection vulnerabilities",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-016279"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "command injection",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202004-019"
}
],
"trust": 0.6
}
}
VAR-202010-0921
Vulnerability from variot - Updated: 2023-12-18 13:37Certain NETGEAR devices are affected by disclosure of sensitive information. This affects WC7500 before 6.5.5.24, WC7600 before 6.5.5.24, WC7600v2 before 6.5.5.24, and WC9500 before 6.5.5.24
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202010-0921",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "wc9500",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "6.5.5.24"
},
{
"model": "wc7500",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "6.5.5.24"
},
{
"model": "wc7600",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "6.5.5.24"
},
{
"model": "wc7500",
"scope": null,
"trust": 0.8,
"vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
"version": null
},
{
"model": "wc7600",
"scope": null,
"trust": 0.8,
"vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
"version": null
},
{
"model": "wc9500",
"scope": null,
"trust": 0.8,
"vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-012208"
},
{
"db": "NVD",
"id": "CVE-2020-26931"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:netgear:wc7500_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "6.5.5.24",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:netgear:wc7500:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:netgear:wc7600_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "6.5.5.24",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:netgear:wc7600:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:netgear:wc7600_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "6.5.5.24",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:netgear:wc7600:v2:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:netgear:wc9500_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "6.5.5.24",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:netgear:wc9500:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2020-26931"
}
]
},
"cve": "CVE-2020-26931",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 3.3,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 6.5,
"impactScore": 2.9,
"integrityImpact": "NONE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "LOW",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Adjacent Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 3.3,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2020-26931",
"impactScore": null,
"integrityImpact": "None",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Low",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
{
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"author": "cve@mitre.org",
"availabilityImpact": "NONE",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.6,
"impactScore": 4.2,
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:L/A:N",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Adjacent Network",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 6.5,
"baseSeverity": "Medium",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2020-26931",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2020-26931",
"trust": 1.8,
"value": "MEDIUM"
},
{
"author": "cve@mitre.org",
"id": "CVE-2020-26931",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-202010-363",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-012208"
},
{
"db": "NVD",
"id": "CVE-2020-26931"
},
{
"db": "NVD",
"id": "CVE-2020-26931"
},
{
"db": "CNNVD",
"id": "CNNVD-202010-363"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Certain NETGEAR devices are affected by disclosure of sensitive information. This affects WC7500 before 6.5.5.24, WC7600 before 6.5.5.24, WC7600v2 before 6.5.5.24, and WC9500 before 6.5.5.24",
"sources": [
{
"db": "NVD",
"id": "CVE-2020-26931"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-012208"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2020-26931",
"trust": 2.4
},
{
"db": "JVNDB",
"id": "JVNDB-2020-012208",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-202010-363",
"trust": 0.6
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-012208"
},
{
"db": "NVD",
"id": "CVE-2020-26931"
},
{
"db": "CNNVD",
"id": "CNNVD-202010-363"
}
]
},
"id": "VAR-202010-0921",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.2513888866666667
},
"last_update_date": "2023-12-18T13:37:39.076000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Security\u00a0Advisory\u00a0for\u00a0Sensitive\u00a0Information\u00a0Disclosure\u00a0on\u00a0Some\u00a0Wireless\u00a0Controllers,\u00a0PSV-2020-0268",
"trust": 0.8,
"url": "https://kb.netgear.com/000062321/security-advisory-for-sensitive-information-disclosure-on-some-wireless-controllers-psv-2020-0268"
},
{
"title": "Multiple NETGEAR Repair measures for device information disclosure vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=131147"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-012208"
},
{
"db": "CNNVD",
"id": "CNNVD-202010-363"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "NVD-CWE-noinfo",
"trust": 1.0
},
{
"problemtype": "information leak (CWE-200) [NVD Evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-012208"
},
{
"db": "NVD",
"id": "CVE-2020-26931"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.6,
"url": "https://kb.netgear.com/000062321/security-advisory-for-sensitive-information-disclosure-on-some-wireless-controllers-psv-2020-0268"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2020-26931"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-012208"
},
{
"db": "NVD",
"id": "CVE-2020-26931"
},
{
"db": "CNNVD",
"id": "CNNVD-202010-363"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2020-012208"
},
{
"db": "NVD",
"id": "CVE-2020-26931"
},
{
"db": "CNNVD",
"id": "CNNVD-202010-363"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-04-27T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2020-012208"
},
{
"date": "2020-10-09T07:15:18.653000",
"db": "NVD",
"id": "CVE-2020-26931"
},
{
"date": "2020-10-09T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202010-363"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-04-27T05:37:00",
"db": "JVNDB",
"id": "JVNDB-2020-012208"
},
{
"date": "2021-07-21T11:39:23.747000",
"db": "NVD",
"id": "CVE-2020-26931"
},
{
"date": "2020-10-21T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202010-363"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote or local",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202010-363"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural \u00a0NETGEAR\u00a0 Information leakage vulnerabilities in devices",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-012208"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "information disclosure",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202010-363"
}
],
"trust": 0.6
}
}
VAR-202010-0589
Vulnerability from variot - Updated: 2023-12-18 12:55Certain NETGEAR devices are affected by stored XSS. This affects WC7500 before 6.5.5.24, WC7600 before 6.5.5.24, WC7600v2 before 6.5.5.24, and WC9500 before 6.5.5.24. plural NETGEAR The product contains a cross-site scripting vulnerability.Information may be obtained and information may be tampered with
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202010-0589",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "wc9500",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "6.5.5.24"
},
{
"model": "wc7500",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "6.5.5.24"
},
{
"model": "wc7600v2",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "6.5.5.24"
},
{
"model": "wc7600",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "6.5.5.24"
},
{
"model": "wc7500",
"scope": null,
"trust": 0.8,
"vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
"version": null
},
{
"model": "wc7600v2",
"scope": null,
"trust": 0.8,
"vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
"version": null
},
{
"model": "wc7600",
"scope": null,
"trust": 0.8,
"vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
"version": null
},
{
"model": "wc9500",
"scope": null,
"trust": 0.8,
"vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-012119"
},
{
"db": "NVD",
"id": "CVE-2020-26923"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:netgear:wc7500_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "6.5.5.24",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:netgear:wc7500:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:netgear:wc7600_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "6.5.5.24",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:netgear:wc7600:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:netgear:wc7600v2_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "6.5.5.24",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:netgear:wc7600v2:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:netgear:wc9500_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "6.5.5.24",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:netgear:wc9500:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2020-26923"
}
]
},
"cve": "CVE-2020-26923",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 3.5,
"confidentialityImpact": "NONE",
"exploitabilityScore": 6.8,
"impactScore": 2.9,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "LOW",
"trust": 1.0,
"userInteractionRequired": true,
"vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Medium",
"accessVector": "Network",
"authentication": "Single",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 3.5,
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2020-26923",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Low",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"exploitabilityScore": 1.7,
"impactScore": 2.7,
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"trust": 1.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"author": "cve@mitre.org",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"exploitabilityScore": 1.2,
"impactScore": 2.7,
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"trust": 1.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 4.8,
"baseSeverity": "Medium",
"confidentialityImpact": "Low",
"exploitabilityScore": null,
"id": "CVE-2020-26923",
"impactScore": null,
"integrityImpact": "Low",
"privilegesRequired": "High",
"scope": "Changed",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2020-26923",
"trust": 1.8,
"value": "MEDIUM"
},
{
"author": "cve@mitre.org",
"id": "CVE-2020-26923",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-202010-355",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-012119"
},
{
"db": "NVD",
"id": "CVE-2020-26923"
},
{
"db": "NVD",
"id": "CVE-2020-26923"
},
{
"db": "CNNVD",
"id": "CNNVD-202010-355"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Certain NETGEAR devices are affected by stored XSS. This affects WC7500 before 6.5.5.24, WC7600 before 6.5.5.24, WC7600v2 before 6.5.5.24, and WC9500 before 6.5.5.24. plural NETGEAR The product contains a cross-site scripting vulnerability.Information may be obtained and information may be tampered with",
"sources": [
{
"db": "NVD",
"id": "CVE-2020-26923"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-012119"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2020-26923",
"trust": 2.4
},
{
"db": "JVNDB",
"id": "JVNDB-2020-012119",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-202010-355",
"trust": 0.6
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-012119"
},
{
"db": "NVD",
"id": "CVE-2020-26923"
},
{
"db": "CNNVD",
"id": "CNNVD-202010-355"
}
]
},
"id": "VAR-202010-0589",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.29270833
},
"last_update_date": "2023-12-18T12:55:52.287000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Security\u00a0Advisory\u00a0for\u00a0Stored\u00a0Cross\u00a0Site\u00a0Scripting\u00a0on\u00a0Some\u00a0Wireless\u00a0Controllers,\u00a0PSV-2020-0180",
"trust": 0.8,
"url": "https://kb.netgear.com/000062329/security-advisory-for-stored-cross-site-scripting-on-some-wireless-controllers-psv-2020-0180"
},
{
"title": "Multiple NETGEAR Fixes for device cross-site scripting vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=131141"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-012119"
},
{
"db": "CNNVD",
"id": "CNNVD-202010-355"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-79",
"trust": 1.0
},
{
"problemtype": "Cross-site scripting (CWE-79) [NVD Evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-012119"
},
{
"db": "NVD",
"id": "CVE-2020-26923"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.6,
"url": "https://kb.netgear.com/000062329/security-advisory-for-stored-cross-site-scripting-on-some-wireless-controllers-psv-2020-0180"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2020-26923"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-012119"
},
{
"db": "NVD",
"id": "CVE-2020-26923"
},
{
"db": "CNNVD",
"id": "CNNVD-202010-355"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2020-012119"
},
{
"db": "NVD",
"id": "CVE-2020-26923"
},
{
"db": "CNNVD",
"id": "CNNVD-202010-355"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-04-26T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2020-012119"
},
{
"date": "2020-10-09T07:15:17.950000",
"db": "NVD",
"id": "CVE-2020-26923"
},
{
"date": "2020-10-09T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202010-355"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-04-26T03:13:00",
"db": "JVNDB",
"id": "JVNDB-2020-012119"
},
{
"date": "2020-10-15T19:44:34.223000",
"db": "NVD",
"id": "CVE-2020-26923"
},
{
"date": "2020-10-21T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202010-355"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202010-355"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural \u00a0NETGEAR\u00a0 Cross-site scripting vulnerabilities in products",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-012119"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "XSS",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202010-355"
}
],
"trust": 0.6
}
}
CVE-2018-11106 (GCVE-0-2018-11106)
Vulnerability from cvelistv5 – Published: 2020-04-01 16:31 – Updated: 2024-08-05 07:54- Other
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T07:54:36.460Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://kb.netgear.com/000058243/Security-Advisory-for-Pre-Authentication-Command-Injection-in-request-handler-php-on-Some-Wireless-Controllers-PSV-2018-0051"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "WC7500",
"vendor": "NETGEAR",
"versions": [
{
"status": "affected",
"version": "firmware versions prior to 6.5.3.5"
}
]
},
{
"product": "WC7520",
"vendor": "NETGEAR",
"versions": [
{
"status": "affected",
"version": "firmware versions prior to 2.5.0.46"
}
]
},
{
"product": "WC7600v1",
"vendor": "NETGEAR",
"versions": [
{
"status": "affected",
"version": "firmware versions prior to 6.5.3.5"
}
]
},
{
"product": "WC7600v2",
"vendor": "NETGEAR",
"versions": [
{
"status": "affected",
"version": "firmware versions prior to 6.5.3.5"
}
]
},
{
"product": "WC9500",
"vendor": "NETGEAR",
"versions": [
{
"status": "affected",
"version": "firmware versions prior to 6.5.3.5"
}
]
}
],
"datePublic": "2018-05-10T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "NETGEAR has released fixes for a pre-authentication command injection in request_handler.php security vulnerability on the following product models: WC7500, running firmware versions prior to 6.5.3.5; WC7520, running firmware versions prior to 2.5.0.46; WC7600v1, running firmware versions prior to 6.5.3.5; WC7600v2, running firmware versions prior to 6.5.3.5; and WC9500, running firmware versions prior to 6.5.3.5."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Other",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-04-01T16:31:45",
"orgId": "a2826606-91e7-4eb6-899e-8484bd4575d5",
"shortName": "netgear"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://kb.netgear.com/000058243/Security-Advisory-for-Pre-Authentication-Command-Injection-in-request-handler-php-on-Some-Wireless-Controllers-PSV-2018-0051"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security@netgear.com",
"ID": "CVE-2018-11106",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "WC7500",
"version": {
"version_data": [
{
"version_value": "firmware versions prior to 6.5.3.5"
}
]
}
},
{
"product_name": "WC7520",
"version": {
"version_data": [
{
"version_value": "firmware versions prior to 2.5.0.46"
}
]
}
},
{
"product_name": "WC7600v1",
"version": {
"version_data": [
{
"version_value": "firmware versions prior to 6.5.3.5"
}
]
}
},
{
"product_name": "WC7600v2",
"version": {
"version_data": [
{
"version_value": "firmware versions prior to 6.5.3.5"
}
]
}
},
{
"product_name": "WC9500",
"version": {
"version_data": [
{
"version_value": "firmware versions prior to 6.5.3.5"
}
]
}
}
]
},
"vendor_name": "NETGEAR"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "NETGEAR has released fixes for a pre-authentication command injection in request_handler.php security vulnerability on the following product models: WC7500, running firmware versions prior to 6.5.3.5; WC7520, running firmware versions prior to 2.5.0.46; WC7600v1, running firmware versions prior to 6.5.3.5; WC7600v2, running firmware versions prior to 6.5.3.5; and WC9500, running firmware versions prior to 6.5.3.5."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Other"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://kb.netgear.com/000058243/Security-Advisory-for-Pre-Authentication-Command-Injection-in-request-handler-php-on-Some-Wireless-Controllers-PSV-2018-0051",
"refsource": "CONFIRM",
"url": "https://kb.netgear.com/000058243/Security-Advisory-for-Pre-Authentication-Command-Injection-in-request-handler-php-on-Some-Wireless-Controllers-PSV-2018-0051"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "a2826606-91e7-4eb6-899e-8484bd4575d5",
"assignerShortName": "netgear",
"cveId": "CVE-2018-11106",
"datePublished": "2020-04-01T16:31:45",
"dateReserved": "2018-05-15T00:00:00",
"dateUpdated": "2024-08-05T07:54:36.460Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-11106 (GCVE-0-2018-11106)
Vulnerability from nvd – Published: 2020-04-01 16:31 – Updated: 2024-08-05 07:54- Other
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T07:54:36.460Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://kb.netgear.com/000058243/Security-Advisory-for-Pre-Authentication-Command-Injection-in-request-handler-php-on-Some-Wireless-Controllers-PSV-2018-0051"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "WC7500",
"vendor": "NETGEAR",
"versions": [
{
"status": "affected",
"version": "firmware versions prior to 6.5.3.5"
}
]
},
{
"product": "WC7520",
"vendor": "NETGEAR",
"versions": [
{
"status": "affected",
"version": "firmware versions prior to 2.5.0.46"
}
]
},
{
"product": "WC7600v1",
"vendor": "NETGEAR",
"versions": [
{
"status": "affected",
"version": "firmware versions prior to 6.5.3.5"
}
]
},
{
"product": "WC7600v2",
"vendor": "NETGEAR",
"versions": [
{
"status": "affected",
"version": "firmware versions prior to 6.5.3.5"
}
]
},
{
"product": "WC9500",
"vendor": "NETGEAR",
"versions": [
{
"status": "affected",
"version": "firmware versions prior to 6.5.3.5"
}
]
}
],
"datePublic": "2018-05-10T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "NETGEAR has released fixes for a pre-authentication command injection in request_handler.php security vulnerability on the following product models: WC7500, running firmware versions prior to 6.5.3.5; WC7520, running firmware versions prior to 2.5.0.46; WC7600v1, running firmware versions prior to 6.5.3.5; WC7600v2, running firmware versions prior to 6.5.3.5; and WC9500, running firmware versions prior to 6.5.3.5."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Other",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-04-01T16:31:45",
"orgId": "a2826606-91e7-4eb6-899e-8484bd4575d5",
"shortName": "netgear"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://kb.netgear.com/000058243/Security-Advisory-for-Pre-Authentication-Command-Injection-in-request-handler-php-on-Some-Wireless-Controllers-PSV-2018-0051"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security@netgear.com",
"ID": "CVE-2018-11106",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "WC7500",
"version": {
"version_data": [
{
"version_value": "firmware versions prior to 6.5.3.5"
}
]
}
},
{
"product_name": "WC7520",
"version": {
"version_data": [
{
"version_value": "firmware versions prior to 2.5.0.46"
}
]
}
},
{
"product_name": "WC7600v1",
"version": {
"version_data": [
{
"version_value": "firmware versions prior to 6.5.3.5"
}
]
}
},
{
"product_name": "WC7600v2",
"version": {
"version_data": [
{
"version_value": "firmware versions prior to 6.5.3.5"
}
]
}
},
{
"product_name": "WC9500",
"version": {
"version_data": [
{
"version_value": "firmware versions prior to 6.5.3.5"
}
]
}
}
]
},
"vendor_name": "NETGEAR"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "NETGEAR has released fixes for a pre-authentication command injection in request_handler.php security vulnerability on the following product models: WC7500, running firmware versions prior to 6.5.3.5; WC7520, running firmware versions prior to 2.5.0.46; WC7600v1, running firmware versions prior to 6.5.3.5; WC7600v2, running firmware versions prior to 6.5.3.5; and WC9500, running firmware versions prior to 6.5.3.5."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Other"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://kb.netgear.com/000058243/Security-Advisory-for-Pre-Authentication-Command-Injection-in-request-handler-php-on-Some-Wireless-Controllers-PSV-2018-0051",
"refsource": "CONFIRM",
"url": "https://kb.netgear.com/000058243/Security-Advisory-for-Pre-Authentication-Command-Injection-in-request-handler-php-on-Some-Wireless-Controllers-PSV-2018-0051"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "a2826606-91e7-4eb6-899e-8484bd4575d5",
"assignerShortName": "netgear",
"cveId": "CVE-2018-11106",
"datePublished": "2020-04-01T16:31:45",
"dateReserved": "2018-05-15T00:00:00",
"dateUpdated": "2024-08-05T07:54:36.460Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}