Search criteria

3 vulnerabilities found for Wemo Insight Smart Plug by Belkin

VAR-201808-1010

Vulnerability from variot - Updated: 2023-12-18 13:18

Stack-based Buffer Overflow vulnerability in libUPnPHndlr.so in Belkin Wemo Insight Smart Plug allows remote attackers to bypass local security protection via a crafted HTTP post packet. Belkin Wemo Insight Smart Plug Contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. BelkinWemoInsightSmartPlug is a smart plug device from Belkin, USA. A stack buffer overflow vulnerability exists in the libUPnPHndlr.so file in BelkinWemoInsightSmartPlug

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201808-1010",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "wemo insight smart plug",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "belkin",
        "version": null
      },
      {
        "model": "wemo insight smart plug",
        "scope": null,
        "trust": 1.4,
        "vendor": "belkin",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-16502"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009336"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-6692"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201808-653"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:belkin:wemo_insight_smart_plug_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:belkin:wemo_insight_smart_plug:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-6692"
      }
    ]
  },
  "cve": "CVE-2018-6692",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "HIGH",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Complete",
            "baseScore": 10.0,
            "confidentialityImpact": "Complete",
            "exploitabilityScore": null,
            "id": "CVE-2018-6692",
            "impactScore": null,
            "integrityImpact": "Complete",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.9,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2018-16502",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "VHN-136724",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 10.0,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "impactScore": 6.0,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "author": "trellixpsirt@trellix.com",
            "availabilityImpact": "NONE",
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 2.2,
            "impactScore": 3.6,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N",
            "version": "3.0"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 10.0,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2018-6692",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Changed",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2018-6692",
            "trust": 1.8,
            "value": "CRITICAL"
          },
          {
            "author": "trellixpsirt@trellix.com",
            "id": "CVE-2018-6692",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2018-16502",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201808-653",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "VULHUB",
            "id": "VHN-136724",
            "trust": 0.1,
            "value": "HIGH"
          },
          {
            "author": "VULMON",
            "id": "CVE-2018-6692",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-16502"
      },
      {
        "db": "VULHUB",
        "id": "VHN-136724"
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-6692"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009336"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-6692"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-6692"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201808-653"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Stack-based Buffer Overflow vulnerability in libUPnPHndlr.so in Belkin Wemo Insight Smart Plug allows remote attackers to bypass local security protection via a crafted HTTP post packet. Belkin Wemo Insight Smart Plug Contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. BelkinWemoInsightSmartPlug is a smart plug device from Belkin, USA. A stack buffer overflow vulnerability exists in the libUPnPHndlr.so file in BelkinWemoInsightSmartPlug",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-6692"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009336"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-16502"
      },
      {
        "db": "VULHUB",
        "id": "VHN-136724"
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-6692"
      }
    ],
    "trust": 2.34
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-6692",
        "trust": 3.2
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009336",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201808-653",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-16502",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-136724",
        "trust": 0.1
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-6692",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-16502"
      },
      {
        "db": "VULHUB",
        "id": "VHN-136724"
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-6692"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009336"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-6692"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201808-653"
      }
    ]
  },
  "id": "VAR-201808-1010",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-16502"
      },
      {
        "db": "VULHUB",
        "id": "VHN-136724"
      }
    ],
    "trust": 1.325
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-16502"
      }
    ]
  },
  "last_update_date": "2023-12-18T13:18:59.748000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Wemo Insight Smart Plug",
        "trust": 0.8,
        "url": "https://www.belkin.com/us/p/p-f7c029/"
      },
      {
        "title": "The Register",
        "trust": 0.2,
        "url": "https://www.theregister.co.uk/2018/08/21/mcafee_flaws_smartplugs/"
      },
      {
        "title": "",
        "trust": 0.1,
        "url": "https://github.com/live-hack-cve/cve-2018-6692 "
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2018-6692"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009336"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.1
      },
      {
        "problemtype": "CWE-119",
        "trust": 0.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-136724"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009336"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-6692"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.6,
        "url": "https://securingtomorrow.mcafee.com/mcafee-labs/insight-into-home-automation-reveals-vulnerability-in-simple-iot-product"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-6692"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-6692"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/787.html"
      },
      {
        "trust": 0.1,
        "url": "https://github.com/live-hack-cve/cve-2018-6692"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      },
      {
        "trust": 0.1,
        "url": "https://www.theregister.co.uk/2018/08/21/mcafee_flaws_smartplugs/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-16502"
      },
      {
        "db": "VULHUB",
        "id": "VHN-136724"
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-6692"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009336"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-6692"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201808-653"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-16502"
      },
      {
        "db": "VULHUB",
        "id": "VHN-136724"
      },
      {
        "db": "VULMON",
        "id": "CVE-2018-6692"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009336"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-6692"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201808-653"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-08-28T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-16502"
      },
      {
        "date": "2018-08-21T00:00:00",
        "db": "VULHUB",
        "id": "VHN-136724"
      },
      {
        "date": "2018-08-21T00:00:00",
        "db": "VULMON",
        "id": "CVE-2018-6692"
      },
      {
        "date": "2018-11-15T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-009336"
      },
      {
        "date": "2018-08-21T14:29:01.750000",
        "db": "NVD",
        "id": "CVE-2018-6692"
      },
      {
        "date": "2018-08-22T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201808-653"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-08-28T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-16502"
      },
      {
        "date": "2023-01-27T00:00:00",
        "db": "VULHUB",
        "id": "VHN-136724"
      },
      {
        "date": "2023-11-07T00:00:00",
        "db": "VULMON",
        "id": "CVE-2018-6692"
      },
      {
        "date": "2018-11-15T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-009336"
      },
      {
        "date": "2023-11-07T03:00:24.990000",
        "db": "NVD",
        "id": "CVE-2018-6692"
      },
      {
        "date": "2020-08-25T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201808-653"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201808-653"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Belkin Wemo Insight Smart Plug Buffer error vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009336"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201808-653"
      }
    ],
    "trust": 1.4
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201808-653"
      }
    ],
    "trust": 0.6
  }
}

CVE-2018-6692 (GCVE-0-2018-6692)

Vulnerability from cvelistv5 – Published: 2018-08-21 14:00 – Updated: 2024-08-05 06:10
VLAI?
Title
Wemo Insight Smart Plug - Remote Code Execution vulnerability
Summary
Stack-based Buffer Overflow vulnerability in libUPnPHndlr.so in Belkin Wemo Insight Smart Plug allows remote attackers to bypass local security protection via a crafted HTTP post packet.
CWE
  • Stack-based Buffer Overflow vulnerability
Assigner
References
Impacted products
Vendor Product Version
Belkin Wemo Insight Smart Plug Affected: WeMo_WW_2.00.11054.PVT-OWRT-Insight , ≤ 2.00.11054 (custom)
Create a notification for this product.
Credits
Doug McKee and the McAfee Advanced Threat Research team.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T06:10:11.342Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://securingtomorrow.mcafee.com/mcafee-labs/insight-into-home-automation-reveals-vulnerability-in-simple-iot-product"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "platforms": [
            "MIPS"
          ],
          "product": "Wemo Insight Smart Plug ",
          "vendor": "Belkin",
          "versions": [
            {
              "lessThanOrEqual": "2.00.11054",
              "status": "affected",
              "version": "WeMo_WW_2.00.11054.PVT-OWRT-Insight",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Doug McKee and the McAfee Advanced Threat Research team."
        }
      ],
      "datePublic": "2018-08-20T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Stack-based Buffer Overflow vulnerability in libUPnPHndlr.so in Belkin Wemo Insight Smart Plug allows remote attackers to bypass local security protection via a crafted HTTP post packet."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Stack-based Buffer Overflow vulnerability",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-08-21T13:57:01",
        "orgId": "01626437-bf8f-4d1c-912a-893b5eb04808",
        "shortName": "trellix"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://securingtomorrow.mcafee.com/mcafee-labs/insight-into-home-automation-reveals-vulnerability-in-simple-iot-product"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Wemo Insight Smart Plug  - Remote Code Execution vulnerability",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@mcafee.com",
          "ID": "CVE-2018-6692",
          "STATE": "PUBLIC",
          "TITLE": "Wemo Insight Smart Plug  - Remote Code Execution vulnerability"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Wemo Insight Smart Plug ",
                      "version": {
                        "version_data": [
                          {
                            "affected": "\u003c=",
                            "platform": "MIPS",
                            "version_affected": "\u003c=",
                            "version_name": "WeMo_WW_2.00.11054.PVT-OWRT-Insight",
                            "version_value": "2.00.11054"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Belkin"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Doug McKee and the McAfee Advanced Threat Research team."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Stack-based Buffer Overflow vulnerability in libUPnPHndlr.so in Belkin Wemo Insight Smart Plug allows remote attackers to bypass local security protection via a crafted HTTP post packet."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Stack-based Buffer Overflow vulnerability"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://securingtomorrow.mcafee.com/mcafee-labs/insight-into-home-automation-reveals-vulnerability-in-simple-iot-product",
              "refsource": "CONFIRM",
              "url": "https://securingtomorrow.mcafee.com/mcafee-labs/insight-into-home-automation-reveals-vulnerability-in-simple-iot-product"
            }
          ]
        },
        "source": {
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "01626437-bf8f-4d1c-912a-893b5eb04808",
    "assignerShortName": "trellix",
    "cveId": "CVE-2018-6692",
    "datePublished": "2018-08-21T14:00:00",
    "dateReserved": "2018-02-06T00:00:00",
    "dateUpdated": "2024-08-05T06:10:11.342Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-6692 (GCVE-0-2018-6692)

Vulnerability from nvd – Published: 2018-08-21 14:00 – Updated: 2024-08-05 06:10
VLAI?
Title
Wemo Insight Smart Plug - Remote Code Execution vulnerability
Summary
Stack-based Buffer Overflow vulnerability in libUPnPHndlr.so in Belkin Wemo Insight Smart Plug allows remote attackers to bypass local security protection via a crafted HTTP post packet.
CWE
  • Stack-based Buffer Overflow vulnerability
Assigner
References
Impacted products
Vendor Product Version
Belkin Wemo Insight Smart Plug Affected: WeMo_WW_2.00.11054.PVT-OWRT-Insight , ≤ 2.00.11054 (custom)
Create a notification for this product.
Credits
Doug McKee and the McAfee Advanced Threat Research team.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T06:10:11.342Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://securingtomorrow.mcafee.com/mcafee-labs/insight-into-home-automation-reveals-vulnerability-in-simple-iot-product"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "platforms": [
            "MIPS"
          ],
          "product": "Wemo Insight Smart Plug ",
          "vendor": "Belkin",
          "versions": [
            {
              "lessThanOrEqual": "2.00.11054",
              "status": "affected",
              "version": "WeMo_WW_2.00.11054.PVT-OWRT-Insight",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Doug McKee and the McAfee Advanced Threat Research team."
        }
      ],
      "datePublic": "2018-08-20T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Stack-based Buffer Overflow vulnerability in libUPnPHndlr.so in Belkin Wemo Insight Smart Plug allows remote attackers to bypass local security protection via a crafted HTTP post packet."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Stack-based Buffer Overflow vulnerability",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-08-21T13:57:01",
        "orgId": "01626437-bf8f-4d1c-912a-893b5eb04808",
        "shortName": "trellix"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://securingtomorrow.mcafee.com/mcafee-labs/insight-into-home-automation-reveals-vulnerability-in-simple-iot-product"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Wemo Insight Smart Plug  - Remote Code Execution vulnerability",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@mcafee.com",
          "ID": "CVE-2018-6692",
          "STATE": "PUBLIC",
          "TITLE": "Wemo Insight Smart Plug  - Remote Code Execution vulnerability"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Wemo Insight Smart Plug ",
                      "version": {
                        "version_data": [
                          {
                            "affected": "\u003c=",
                            "platform": "MIPS",
                            "version_affected": "\u003c=",
                            "version_name": "WeMo_WW_2.00.11054.PVT-OWRT-Insight",
                            "version_value": "2.00.11054"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Belkin"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Doug McKee and the McAfee Advanced Threat Research team."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Stack-based Buffer Overflow vulnerability in libUPnPHndlr.so in Belkin Wemo Insight Smart Plug allows remote attackers to bypass local security protection via a crafted HTTP post packet."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Stack-based Buffer Overflow vulnerability"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://securingtomorrow.mcafee.com/mcafee-labs/insight-into-home-automation-reveals-vulnerability-in-simple-iot-product",
              "refsource": "CONFIRM",
              "url": "https://securingtomorrow.mcafee.com/mcafee-labs/insight-into-home-automation-reveals-vulnerability-in-simple-iot-product"
            }
          ]
        },
        "source": {
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "01626437-bf8f-4d1c-912a-893b5eb04808",
    "assignerShortName": "trellix",
    "cveId": "CVE-2018-6692",
    "datePublished": "2018-08-21T14:00:00",
    "dateReserved": "2018-02-06T00:00:00",
    "dateUpdated": "2024-08-05T06:10:11.342Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}