Search criteria
3 vulnerabilities found for Wemo Insight Smart Plug by Belkin
VAR-201808-1010
Vulnerability from variot - Updated: 2023-12-18 13:18Stack-based Buffer Overflow vulnerability in libUPnPHndlr.so in Belkin Wemo Insight Smart Plug allows remote attackers to bypass local security protection via a crafted HTTP post packet. Belkin Wemo Insight Smart Plug Contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. BelkinWemoInsightSmartPlug is a smart plug device from Belkin, USA. A stack buffer overflow vulnerability exists in the libUPnPHndlr.so file in BelkinWemoInsightSmartPlug
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201808-1010",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "wemo insight smart plug",
"scope": "eq",
"trust": 1.6,
"vendor": "belkin",
"version": null
},
{
"model": "wemo insight smart plug",
"scope": null,
"trust": 1.4,
"vendor": "belkin",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-16502"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-009336"
},
{
"db": "NVD",
"id": "CVE-2018-6692"
},
{
"db": "CNNVD",
"id": "CNNVD-201808-653"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:belkin:wemo_insight_smart_plug_firmware:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:belkin:wemo_insight_smart_plug:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2018-6692"
}
]
},
"cve": "CVE-2018-6692",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Complete",
"baseScore": 10.0,
"confidentialityImpact": "Complete",
"exploitabilityScore": null,
"id": "CVE-2018-6692",
"impactScore": null,
"integrityImpact": "Complete",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.9,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CNVD-2018-16502",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "VHN-136724",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 10.0,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 6.0,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"author": "trellixpsirt@trellix.com",
"availabilityImpact": "NONE",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"exploitabilityScore": 2.2,
"impactScore": 3.6,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 10.0,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2018-6692",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Changed",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2018-6692",
"trust": 1.8,
"value": "CRITICAL"
},
{
"author": "trellixpsirt@trellix.com",
"id": "CVE-2018-6692",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "CNVD",
"id": "CNVD-2018-16502",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201808-653",
"trust": 0.6,
"value": "CRITICAL"
},
{
"author": "VULHUB",
"id": "VHN-136724",
"trust": 0.1,
"value": "HIGH"
},
{
"author": "VULMON",
"id": "CVE-2018-6692",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-16502"
},
{
"db": "VULHUB",
"id": "VHN-136724"
},
{
"db": "VULMON",
"id": "CVE-2018-6692"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-009336"
},
{
"db": "NVD",
"id": "CVE-2018-6692"
},
{
"db": "NVD",
"id": "CVE-2018-6692"
},
{
"db": "CNNVD",
"id": "CNNVD-201808-653"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Stack-based Buffer Overflow vulnerability in libUPnPHndlr.so in Belkin Wemo Insight Smart Plug allows remote attackers to bypass local security protection via a crafted HTTP post packet. Belkin Wemo Insight Smart Plug Contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. BelkinWemoInsightSmartPlug is a smart plug device from Belkin, USA. A stack buffer overflow vulnerability exists in the libUPnPHndlr.so file in BelkinWemoInsightSmartPlug",
"sources": [
{
"db": "NVD",
"id": "CVE-2018-6692"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-009336"
},
{
"db": "CNVD",
"id": "CNVD-2018-16502"
},
{
"db": "VULHUB",
"id": "VHN-136724"
},
{
"db": "VULMON",
"id": "CVE-2018-6692"
}
],
"trust": 2.34
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2018-6692",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2018-009336",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201808-653",
"trust": 0.7
},
{
"db": "CNVD",
"id": "CNVD-2018-16502",
"trust": 0.6
},
{
"db": "VULHUB",
"id": "VHN-136724",
"trust": 0.1
},
{
"db": "VULMON",
"id": "CVE-2018-6692",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-16502"
},
{
"db": "VULHUB",
"id": "VHN-136724"
},
{
"db": "VULMON",
"id": "CVE-2018-6692"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-009336"
},
{
"db": "NVD",
"id": "CVE-2018-6692"
},
{
"db": "CNNVD",
"id": "CNNVD-201808-653"
}
]
},
"id": "VAR-201808-1010",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-16502"
},
{
"db": "VULHUB",
"id": "VHN-136724"
}
],
"trust": 1.325
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-16502"
}
]
},
"last_update_date": "2023-12-18T13:18:59.748000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Wemo Insight Smart Plug",
"trust": 0.8,
"url": "https://www.belkin.com/us/p/p-f7c029/"
},
{
"title": "The Register",
"trust": 0.2,
"url": "https://www.theregister.co.uk/2018/08/21/mcafee_flaws_smartplugs/"
},
{
"title": "",
"trust": 0.1,
"url": "https://github.com/live-hack-cve/cve-2018-6692 "
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2018-6692"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-009336"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.1
},
{
"problemtype": "CWE-119",
"trust": 0.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-136724"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-009336"
},
{
"db": "NVD",
"id": "CVE-2018-6692"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.6,
"url": "https://securingtomorrow.mcafee.com/mcafee-labs/insight-into-home-automation-reveals-vulnerability-in-simple-iot-product"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2018-6692"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-6692"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/787.html"
},
{
"trust": 0.1,
"url": "https://github.com/live-hack-cve/cve-2018-6692"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
},
{
"trust": 0.1,
"url": "https://www.theregister.co.uk/2018/08/21/mcafee_flaws_smartplugs/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-16502"
},
{
"db": "VULHUB",
"id": "VHN-136724"
},
{
"db": "VULMON",
"id": "CVE-2018-6692"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-009336"
},
{
"db": "NVD",
"id": "CVE-2018-6692"
},
{
"db": "CNNVD",
"id": "CNNVD-201808-653"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2018-16502"
},
{
"db": "VULHUB",
"id": "VHN-136724"
},
{
"db": "VULMON",
"id": "CVE-2018-6692"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-009336"
},
{
"db": "NVD",
"id": "CVE-2018-6692"
},
{
"db": "CNNVD",
"id": "CNNVD-201808-653"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2018-08-28T00:00:00",
"db": "CNVD",
"id": "CNVD-2018-16502"
},
{
"date": "2018-08-21T00:00:00",
"db": "VULHUB",
"id": "VHN-136724"
},
{
"date": "2018-08-21T00:00:00",
"db": "VULMON",
"id": "CVE-2018-6692"
},
{
"date": "2018-11-15T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-009336"
},
{
"date": "2018-08-21T14:29:01.750000",
"db": "NVD",
"id": "CVE-2018-6692"
},
{
"date": "2018-08-22T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201808-653"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2018-08-28T00:00:00",
"db": "CNVD",
"id": "CNVD-2018-16502"
},
{
"date": "2023-01-27T00:00:00",
"db": "VULHUB",
"id": "VHN-136724"
},
{
"date": "2023-11-07T00:00:00",
"db": "VULMON",
"id": "CVE-2018-6692"
},
{
"date": "2018-11-15T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-009336"
},
{
"date": "2023-11-07T03:00:24.990000",
"db": "NVD",
"id": "CVE-2018-6692"
},
{
"date": "2020-08-25T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201808-653"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201808-653"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Belkin Wemo Insight Smart Plug Buffer error vulnerability",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-009336"
},
{
"db": "CNNVD",
"id": "CNNVD-201808-653"
}
],
"trust": 1.4
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201808-653"
}
],
"trust": 0.6
}
}
CVE-2018-6692 (GCVE-0-2018-6692)
Vulnerability from cvelistv5 – Published: 2018-08-21 14:00 – Updated: 2024-08-05 06:10
VLAI?
Title
Wemo Insight Smart Plug - Remote Code Execution vulnerability
Summary
Stack-based Buffer Overflow vulnerability in libUPnPHndlr.so in Belkin Wemo Insight Smart Plug allows remote attackers to bypass local security protection via a crafted HTTP post packet.
Severity ?
5.9 (Medium)
CWE
- Stack-based Buffer Overflow vulnerability
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Belkin | Wemo Insight Smart Plug |
Affected:
WeMo_WW_2.00.11054.PVT-OWRT-Insight , ≤ 2.00.11054
(custom)
|
Credits
Doug McKee and the McAfee Advanced Threat Research team.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:10:11.342Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://securingtomorrow.mcafee.com/mcafee-labs/insight-into-home-automation-reveals-vulnerability-in-simple-iot-product"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"platforms": [
"MIPS"
],
"product": "Wemo Insight Smart Plug ",
"vendor": "Belkin",
"versions": [
{
"lessThanOrEqual": "2.00.11054",
"status": "affected",
"version": "WeMo_WW_2.00.11054.PVT-OWRT-Insight",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Doug McKee and the McAfee Advanced Threat Research team."
}
],
"datePublic": "2018-08-20T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Stack-based Buffer Overflow vulnerability in libUPnPHndlr.so in Belkin Wemo Insight Smart Plug allows remote attackers to bypass local security protection via a crafted HTTP post packet."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Stack-based Buffer Overflow vulnerability",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-08-21T13:57:01",
"orgId": "01626437-bf8f-4d1c-912a-893b5eb04808",
"shortName": "trellix"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://securingtomorrow.mcafee.com/mcafee-labs/insight-into-home-automation-reveals-vulnerability-in-simple-iot-product"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Wemo Insight Smart Plug - Remote Code Execution vulnerability",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@mcafee.com",
"ID": "CVE-2018-6692",
"STATE": "PUBLIC",
"TITLE": "Wemo Insight Smart Plug - Remote Code Execution vulnerability"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Wemo Insight Smart Plug ",
"version": {
"version_data": [
{
"affected": "\u003c=",
"platform": "MIPS",
"version_affected": "\u003c=",
"version_name": "WeMo_WW_2.00.11054.PVT-OWRT-Insight",
"version_value": "2.00.11054"
}
]
}
}
]
},
"vendor_name": "Belkin"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Doug McKee and the McAfee Advanced Threat Research team."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Stack-based Buffer Overflow vulnerability in libUPnPHndlr.so in Belkin Wemo Insight Smart Plug allows remote attackers to bypass local security protection via a crafted HTTP post packet."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Stack-based Buffer Overflow vulnerability"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://securingtomorrow.mcafee.com/mcafee-labs/insight-into-home-automation-reveals-vulnerability-in-simple-iot-product",
"refsource": "CONFIRM",
"url": "https://securingtomorrow.mcafee.com/mcafee-labs/insight-into-home-automation-reveals-vulnerability-in-simple-iot-product"
}
]
},
"source": {
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "01626437-bf8f-4d1c-912a-893b5eb04808",
"assignerShortName": "trellix",
"cveId": "CVE-2018-6692",
"datePublished": "2018-08-21T14:00:00",
"dateReserved": "2018-02-06T00:00:00",
"dateUpdated": "2024-08-05T06:10:11.342Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-6692 (GCVE-0-2018-6692)
Vulnerability from nvd – Published: 2018-08-21 14:00 – Updated: 2024-08-05 06:10
VLAI?
Title
Wemo Insight Smart Plug - Remote Code Execution vulnerability
Summary
Stack-based Buffer Overflow vulnerability in libUPnPHndlr.so in Belkin Wemo Insight Smart Plug allows remote attackers to bypass local security protection via a crafted HTTP post packet.
Severity ?
5.9 (Medium)
CWE
- Stack-based Buffer Overflow vulnerability
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Belkin | Wemo Insight Smart Plug |
Affected:
WeMo_WW_2.00.11054.PVT-OWRT-Insight , ≤ 2.00.11054
(custom)
|
Credits
Doug McKee and the McAfee Advanced Threat Research team.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:10:11.342Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://securingtomorrow.mcafee.com/mcafee-labs/insight-into-home-automation-reveals-vulnerability-in-simple-iot-product"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"platforms": [
"MIPS"
],
"product": "Wemo Insight Smart Plug ",
"vendor": "Belkin",
"versions": [
{
"lessThanOrEqual": "2.00.11054",
"status": "affected",
"version": "WeMo_WW_2.00.11054.PVT-OWRT-Insight",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Doug McKee and the McAfee Advanced Threat Research team."
}
],
"datePublic": "2018-08-20T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Stack-based Buffer Overflow vulnerability in libUPnPHndlr.so in Belkin Wemo Insight Smart Plug allows remote attackers to bypass local security protection via a crafted HTTP post packet."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Stack-based Buffer Overflow vulnerability",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-08-21T13:57:01",
"orgId": "01626437-bf8f-4d1c-912a-893b5eb04808",
"shortName": "trellix"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://securingtomorrow.mcafee.com/mcafee-labs/insight-into-home-automation-reveals-vulnerability-in-simple-iot-product"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Wemo Insight Smart Plug - Remote Code Execution vulnerability",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@mcafee.com",
"ID": "CVE-2018-6692",
"STATE": "PUBLIC",
"TITLE": "Wemo Insight Smart Plug - Remote Code Execution vulnerability"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Wemo Insight Smart Plug ",
"version": {
"version_data": [
{
"affected": "\u003c=",
"platform": "MIPS",
"version_affected": "\u003c=",
"version_name": "WeMo_WW_2.00.11054.PVT-OWRT-Insight",
"version_value": "2.00.11054"
}
]
}
}
]
},
"vendor_name": "Belkin"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Doug McKee and the McAfee Advanced Threat Research team."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Stack-based Buffer Overflow vulnerability in libUPnPHndlr.so in Belkin Wemo Insight Smart Plug allows remote attackers to bypass local security protection via a crafted HTTP post packet."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Stack-based Buffer Overflow vulnerability"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://securingtomorrow.mcafee.com/mcafee-labs/insight-into-home-automation-reveals-vulnerability-in-simple-iot-product",
"refsource": "CONFIRM",
"url": "https://securingtomorrow.mcafee.com/mcafee-labs/insight-into-home-automation-reveals-vulnerability-in-simple-iot-product"
}
]
},
"source": {
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "01626437-bf8f-4d1c-912a-893b5eb04808",
"assignerShortName": "trellix",
"cveId": "CVE-2018-6692",
"datePublished": "2018-08-21T14:00:00",
"dateReserved": "2018-02-06T00:00:00",
"dateUpdated": "2024-08-05T06:10:11.342Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",