Search criteria
3 vulnerabilities found for Wireless 1420 Gateway by Emerson
VAR-202109-0005
Vulnerability from variot - Updated: 2024-02-13 01:59There is a flaw in the code used to configure the internal gateway firewall when the gateway's VLAN feature is enabled. If a user enables the VLAN setting, the internal gateway firewall becomes disabled resulting in exposure of all ports used by the gateway. Emerson Provides Emerson WirelessHART Gateway Contains improper access control vulnerabilities. Emerson WirelessHART Gateway Is Emerson It is an industrial wireless gateway device provided by
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202109-0005",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "wireless 1410 gateway",
"scope": "gte",
"trust": 1.0,
"vendor": "emerson",
"version": "4.6.43"
},
{
"model": "wireless 1552wu gateway",
"scope": "lte",
"trust": 1.0,
"vendor": "emerson",
"version": "4.7.84"
},
{
"model": "wireless 1420 gateway",
"scope": "lte",
"trust": 1.0,
"vendor": "emerson",
"version": "4.7.84"
},
{
"model": "wireless 1552wu gateway",
"scope": "gte",
"trust": 1.0,
"vendor": "emerson",
"version": "4.6.43"
},
{
"model": "wireless 1410 gateway",
"scope": "lte",
"trust": 1.0,
"vendor": "emerson",
"version": "4.7.84"
},
{
"model": "wireless 1420 gateway",
"scope": "gte",
"trust": 1.0,
"vendor": "emerson",
"version": "4.6.43"
},
{
"model": "wireless 1410 gateway",
"scope": "eq",
"trust": 0.8,
"vendor": "emerson",
"version": "revision 4.6.43 \u304b\u3089 4.7.84"
},
{
"model": "wireless 1420 gateway",
"scope": "eq",
"trust": 0.8,
"vendor": "emerson",
"version": "revision 4.6.43 \u304b\u3089 4.7.84"
},
{
"model": "wireless 1552wu gateway",
"scope": "eq",
"trust": 0.8,
"vendor": "emerson",
"version": "4.6.43 \u304b\u3089 4.7.84"
},
{
"model": "electric wireless gateway",
"scope": "eq",
"trust": 0.6,
"vendor": "emerson",
"version": "1410\u003e=4.6.43,\u003c=4.7.84"
},
{
"model": "electric wireless gateway",
"scope": "eq",
"trust": 0.6,
"vendor": "emerson",
"version": "1420\u003e=4.6.43,\u003c=4.7.84"
},
{
"model": "electric wireless 1552wu gateway",
"scope": "gte",
"trust": 0.6,
"vendor": "emerson",
"version": "4.6.43,\u003c=4.7.84"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-36949"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-004483"
},
{
"db": "NVD",
"id": "CVE-2020-12030"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:emerson:wireless_1410_gateway_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "4.7.84",
"versionStartIncluding": "4.6.43",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:emerson:wireless_1410_gateway:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:emerson:wireless_1420_gateway_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "4.7.84",
"versionStartIncluding": "4.6.43",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:emerson:wireless_1420_gateway:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:emerson:wireless_1552wu_gateway_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "4.7.84",
"versionStartIncluding": "4.6.43",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:emerson:wireless_1552wu_gateway:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2020-12030"
}
]
},
"cve": "CVE-2020-12030",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.6,
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2020-36949",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULMON",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.6,
"id": "CVE-2020-12030",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "MEDIUM",
"trust": 0.1,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 10.0,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 6.0,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "IPA score",
"availabilityImpact": "High",
"baseScore": 10,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2020-004483",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Changed",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2020-12030",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "ics-cert@hq.dhs.gov",
"id": "CVE-2020-12030",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "IPA",
"id": "JVNDB-2020-004483",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2020-36949",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202005-800",
"trust": 0.6,
"value": "CRITICAL"
},
{
"author": "VULMON",
"id": "CVE-2020-12030",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-36949"
},
{
"db": "VULMON",
"id": "CVE-2020-12030"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-004483"
},
{
"db": "CNNVD",
"id": "CNNVD-202005-800"
},
{
"db": "NVD",
"id": "CVE-2020-12030"
},
{
"db": "NVD",
"id": "CVE-2020-12030"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "There is a flaw in the code used to configure the internal gateway firewall when the gateway\u0027s VLAN feature is enabled. If a user enables the VLAN setting, the internal gateway firewall becomes disabled resulting in exposure of all ports used by the gateway. Emerson Provides Emerson WirelessHART Gateway Contains improper access control vulnerabilities. Emerson WirelessHART Gateway Is Emerson It is an industrial wireless gateway device provided by",
"sources": [
{
"db": "NVD",
"id": "CVE-2020-12030"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-004483"
},
{
"db": "CNVD",
"id": "CNVD-2020-36949"
},
{
"db": "VULMON",
"id": "CVE-2020-12030"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "ICS CERT",
"id": "ICSA-20-135-02",
"trust": 3.1
},
{
"db": "NVD",
"id": "CVE-2020-12030",
"trust": 3.1
},
{
"db": "JVN",
"id": "JVNVU94025006",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2020-004483",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2020-36949",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202005-800",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2020-12030",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-36949"
},
{
"db": "VULMON",
"id": "CVE-2020-12030"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-004483"
},
{
"db": "CNNVD",
"id": "CNNVD-202005-800"
},
{
"db": "NVD",
"id": "CVE-2020-12030"
}
]
},
"id": "VAR-202109-0005",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-36949"
}
],
"trust": 1.4333333499999998
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS",
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-36949"
}
]
},
"last_update_date": "2024-02-13T01:59:48.514000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "emerson Wireless 1410 Gateway",
"trust": 0.8,
"url": "https://www.emerson.com/en-br/catalog/emerson-sku-1410-wireless-gateway"
},
{
"title": "Patch for Multiple Emerson Electric products access control error vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/225029"
},
{
"title": "Multiple Emerson Electric Product access control error vulnerability fixes",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=118753"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-36949"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-004483"
},
{
"db": "CNNVD",
"id": "CNNVD-202005-800"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "NVD-CWE-Other",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2020-12030"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.0,
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-135-02"
},
{
"trust": 1.7,
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-135-02"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-12030"
},
{
"trust": 0.8,
"url": "http://jvn.jp/cert/jvnvu94025006"
},
{
"trust": 0.6,
"url": "https://nvd.nist.gov/vuln/detail/cve-2020-12030"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-36949"
},
{
"db": "VULMON",
"id": "CVE-2020-12030"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-004483"
},
{
"db": "CNNVD",
"id": "CNNVD-202005-800"
},
{
"db": "NVD",
"id": "CVE-2020-12030"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2020-36949"
},
{
"db": "VULMON",
"id": "CVE-2020-12030"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-004483"
},
{
"db": "CNNVD",
"id": "CNNVD-202005-800"
},
{
"db": "NVD",
"id": "CVE-2020-12030"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-07-09T00:00:00",
"db": "CNVD",
"id": "CNVD-2020-36949"
},
{
"date": "2021-09-29T00:00:00",
"db": "VULMON",
"id": "CVE-2020-12030"
},
{
"date": "2020-05-18T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2020-004483"
},
{
"date": "2020-05-14T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202005-800"
},
{
"date": "2021-09-29T20:15:07.870000",
"db": "NVD",
"id": "CVE-2020-12030"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-07-09T00:00:00",
"db": "CNVD",
"id": "CNVD-2020-36949"
},
{
"date": "2022-07-08T00:00:00",
"db": "VULMON",
"id": "CVE-2020-12030"
},
{
"date": "2020-05-18T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2020-004483"
},
{
"date": "2022-07-11T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202005-800"
},
{
"date": "2022-07-08T18:20:47.457000",
"db": "NVD",
"id": "CVE-2020-12030"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202005-800"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Emerson WirelessHART Gateway Improper access control vulnerabilities",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-004483"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "other",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202005-800"
}
],
"trust": 0.6
}
}
CVE-2020-12030 (GCVE-0-2020-12030)
Vulnerability from cvelistv5 – Published: 2021-09-29 19:36 – Updated: 2024-08-04 11:48
VLAI?
Summary
There is a flaw in the code used to configure the internal gateway firewall when the gateway's VLAN feature is enabled. If a user enables the VLAN setting, the internal gateway firewall becomes disabled resulting in exposure of all ports used by the gateway.
Severity ?
10 (Critical)
CWE
- CWE-284 - IMPROPER ACCESS CONTROL CWE-284
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Emerson | Wireless 1410 Gateway |
Affected:
4.6.43 , ≤ 4.7.84
(custom)
|
||||||||||||
|
||||||||||||||
Credits
Emerson discovered this vulnerability and reported it to CISA once there was a solution.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T11:48:57.679Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-135-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Wireless 1410 Gateway",
"vendor": "Emerson",
"versions": [
{
"lessThanOrEqual": "4.7.84",
"status": "affected",
"version": "4.6.43",
"versionType": "custom"
}
]
},
{
"product": "Wireless 1420 Gateway",
"vendor": "Emerson",
"versions": [
{
"lessThanOrEqual": "4.7.84",
"status": "affected",
"version": "4.6.43",
"versionType": "custom"
}
]
},
{
"product": "Wireless 1552WU Gateway",
"vendor": "Emerson",
"versions": [
{
"lessThanOrEqual": "4.7.84",
"status": "affected",
"version": "4.6.43",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Emerson discovered this vulnerability and reported it to CISA once there was a solution."
}
],
"descriptions": [
{
"lang": "en",
"value": "There is a flaw in the code used to configure the internal gateway firewall when the gateway\u0027s VLAN feature is enabled. If a user enables the VLAN setting, the internal gateway firewall becomes disabled resulting in exposure of all ports used by the gateway."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": " IMPROPER ACCESS CONTROL CWE-284",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-09-29T19:36:38",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-135-02"
}
],
"solutions": [
{
"lang": "en",
"value": "Emerson recommends end users update the firmware on VLAN-enabled Version 4 gateways as soon as possible.\n\nIf the VLAN feature is not enabled, no immediate action is necessary.\nPlease see Emerson\u2019s cybersecurity notification alert number EMR.RMT20001-1 for more information."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Emerson WirelessHART Gateway",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-12030",
"STATE": "PUBLIC",
"TITLE": "Emerson WirelessHART Gateway"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Wireless 1410 Gateway",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "4.6.43",
"version_value": "4.7.84"
}
]
}
},
{
"product_name": "Wireless 1420 Gateway",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "4.6.43",
"version_value": "4.7.84"
}
]
}
},
{
"product_name": "Wireless 1552WU Gateway",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "4.6.43",
"version_value": "4.7.84"
}
]
}
}
]
},
"vendor_name": "Emerson"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Emerson discovered this vulnerability and reported it to CISA once there was a solution."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "There is a flaw in the code used to configure the internal gateway firewall when the gateway\u0027s VLAN feature is enabled. If a user enables the VLAN setting, the internal gateway firewall becomes disabled resulting in exposure of all ports used by the gateway."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": " IMPROPER ACCESS CONTROL CWE-284"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-135-02",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-135-02"
}
]
},
"solution": [
{
"lang": "en",
"value": "Emerson recommends end users update the firmware on VLAN-enabled Version 4 gateways as soon as possible.\n\nIf the VLAN feature is not enabled, no immediate action is necessary.\nPlease see Emerson\u2019s cybersecurity notification alert number EMR.RMT20001-1 for more information."
}
],
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-12030",
"datePublished": "2021-09-29T19:36:38",
"dateReserved": "2020-04-21T00:00:00",
"dateUpdated": "2024-08-04T11:48:57.679Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-12030 (GCVE-0-2020-12030)
Vulnerability from nvd – Published: 2021-09-29 19:36 – Updated: 2024-08-04 11:48
VLAI?
Summary
There is a flaw in the code used to configure the internal gateway firewall when the gateway's VLAN feature is enabled. If a user enables the VLAN setting, the internal gateway firewall becomes disabled resulting in exposure of all ports used by the gateway.
Severity ?
10 (Critical)
CWE
- CWE-284 - IMPROPER ACCESS CONTROL CWE-284
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Emerson | Wireless 1410 Gateway |
Affected:
4.6.43 , ≤ 4.7.84
(custom)
|
||||||||||||
|
||||||||||||||
Credits
Emerson discovered this vulnerability and reported it to CISA once there was a solution.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T11:48:57.679Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-135-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Wireless 1410 Gateway",
"vendor": "Emerson",
"versions": [
{
"lessThanOrEqual": "4.7.84",
"status": "affected",
"version": "4.6.43",
"versionType": "custom"
}
]
},
{
"product": "Wireless 1420 Gateway",
"vendor": "Emerson",
"versions": [
{
"lessThanOrEqual": "4.7.84",
"status": "affected",
"version": "4.6.43",
"versionType": "custom"
}
]
},
{
"product": "Wireless 1552WU Gateway",
"vendor": "Emerson",
"versions": [
{
"lessThanOrEqual": "4.7.84",
"status": "affected",
"version": "4.6.43",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Emerson discovered this vulnerability and reported it to CISA once there was a solution."
}
],
"descriptions": [
{
"lang": "en",
"value": "There is a flaw in the code used to configure the internal gateway firewall when the gateway\u0027s VLAN feature is enabled. If a user enables the VLAN setting, the internal gateway firewall becomes disabled resulting in exposure of all ports used by the gateway."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": " IMPROPER ACCESS CONTROL CWE-284",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-09-29T19:36:38",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-135-02"
}
],
"solutions": [
{
"lang": "en",
"value": "Emerson recommends end users update the firmware on VLAN-enabled Version 4 gateways as soon as possible.\n\nIf the VLAN feature is not enabled, no immediate action is necessary.\nPlease see Emerson\u2019s cybersecurity notification alert number EMR.RMT20001-1 for more information."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Emerson WirelessHART Gateway",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-12030",
"STATE": "PUBLIC",
"TITLE": "Emerson WirelessHART Gateway"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Wireless 1410 Gateway",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "4.6.43",
"version_value": "4.7.84"
}
]
}
},
{
"product_name": "Wireless 1420 Gateway",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "4.6.43",
"version_value": "4.7.84"
}
]
}
},
{
"product_name": "Wireless 1552WU Gateway",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "4.6.43",
"version_value": "4.7.84"
}
]
}
}
]
},
"vendor_name": "Emerson"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Emerson discovered this vulnerability and reported it to CISA once there was a solution."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "There is a flaw in the code used to configure the internal gateway firewall when the gateway\u0027s VLAN feature is enabled. If a user enables the VLAN setting, the internal gateway firewall becomes disabled resulting in exposure of all ports used by the gateway."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": " IMPROPER ACCESS CONTROL CWE-284"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-135-02",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-135-02"
}
]
},
"solution": [
{
"lang": "en",
"value": "Emerson recommends end users update the firmware on VLAN-enabled Version 4 gateways as soon as possible.\n\nIf the VLAN feature is not enabled, no immediate action is necessary.\nPlease see Emerson\u2019s cybersecurity notification alert number EMR.RMT20001-1 for more information."
}
],
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-12030",
"datePublished": "2021-09-29T19:36:38",
"dateReserved": "2020-04-21T00:00:00",
"dateUpdated": "2024-08-04T11:48:57.679Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",