Search criteria
2 vulnerabilities found for Xpedition Layout Browser by Siemens
CVE-2023-30900 (GCVE-0-2023-30900)
Vulnerability from cvelistv5 – Published: 2023-10-10 10:21 – Updated: 2025-02-27 20:46
VLAI?
Summary
A vulnerability has been identified in Xpedition Layout Browser (All versions < VX.2.14). Affected application contains a stack overflow vulnerability when parsing a PCB file. An attacker can leverage this vulnerability to execute code in the context of the current process.
Severity ?
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Siemens | Xpedition Layout Browser |
Affected:
All versions < VX.2.14
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T14:37:15.530Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-829656.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-30900",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-26T21:50:28.689894Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-27T20:46:14.714Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Xpedition Layout Browser",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c VX.2.14"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Xpedition Layout Browser (All versions \u003c VX.2.14). Affected application contains a stack overflow vulnerability when parsing a PCB file. An attacker can leverage this vulnerability to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121: Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-10T10:21:19.684Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-829656.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-30900",
"datePublished": "2023-10-10T10:21:19.684Z",
"dateReserved": "2023-04-20T12:49:03.481Z",
"dateUpdated": "2025-02-27T20:46:14.714Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-30900 (GCVE-0-2023-30900)
Vulnerability from nvd – Published: 2023-10-10 10:21 – Updated: 2025-02-27 20:46
VLAI?
Summary
A vulnerability has been identified in Xpedition Layout Browser (All versions < VX.2.14). Affected application contains a stack overflow vulnerability when parsing a PCB file. An attacker can leverage this vulnerability to execute code in the context of the current process.
Severity ?
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Siemens | Xpedition Layout Browser |
Affected:
All versions < VX.2.14
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T14:37:15.530Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-829656.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-30900",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-26T21:50:28.689894Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-27T20:46:14.714Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Xpedition Layout Browser",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c VX.2.14"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Xpedition Layout Browser (All versions \u003c VX.2.14). Affected application contains a stack overflow vulnerability when parsing a PCB file. An attacker can leverage this vulnerability to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121: Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-10T10:21:19.684Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-829656.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-30900",
"datePublished": "2023-10-10T10:21:19.684Z",
"dateReserved": "2023-04-20T12:49:03.481Z",
"dateUpdated": "2025-02-27T20:46:14.714Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}