Search criteria
3 vulnerabilities found for bas920_firmware by basystems
FKIE_CVE-2017-17974
Vulnerability from fkie_nvd - Published: 2017-12-29 21:29 - Updated: 2025-04-20 01:37
Severity ?
Summary
BA SYSTEMS BAS Web on BAS920 devices (with Firmware 01.01.00*, HTTPserv 00002, and Script 02.*) and ISC2000 devices allows remote attackers to obtain sensitive information via a request for isc/get_sid_js.aspx or isc/get_sid.aspx, as demonstrated by obtaining administrative access by subsequently using the credential information for the Supervisor/Administrator account.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | http://misteralfa-hack.blogspot.cl/2017/12/ba-system-improper-access-control.html | Exploit, Third Party Advisory | |
| cve@mitre.org | https://github.com/ezelf/baCK_system | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | http://misteralfa-hack.blogspot.cl/2017/12/ba-system-improper-access-control.html | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://github.com/ezelf/baCK_system | Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| basystems | bas920_firmware | 01.01.00 | |
| basystems | bas920 | - | |
| basystems | isc2000_firmware | 01.01.00 | |
| basystems | isc2000 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:basystems:bas920_firmware:01.01.00:*:*:*:*:*:*:*",
"matchCriteriaId": "01041B98-330D-47BE-8D6C-938A3507E6DF",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:basystems:bas920:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C3ADFDDE-374C-4A3C-AC31-61A73E24AF66",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:basystems:isc2000_firmware:01.01.00:*:*:*:*:*:*:*",
"matchCriteriaId": "D5BBF686-8368-4571-9EBB-866B0A3AD3D6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:basystems:isc2000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6D54BD94-6B60-426F-A48A-215C6043326C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "BA SYSTEMS BAS Web on BAS920 devices (with Firmware 01.01.00*, HTTPserv 00002, and Script 02.*) and ISC2000 devices allows remote attackers to obtain sensitive information via a request for isc/get_sid_js.aspx or isc/get_sid.aspx, as demonstrated by obtaining administrative access by subsequently using the credential information for the Supervisor/Administrator account."
},
{
"lang": "es",
"value": "BA SYSTEMS BAS Web en dispositivos BAS920 (con Firmware 01.01.00*, HTTPserv 00002 y Script 02.*) y ISC2000 permite que atacantes remotos obtengan informaci\u00f3n sensible mediante una petici\u00f3n a isc/get_sid_js.aspx o isc/get_sid.aspx, tal y como se demuestra obteniendo acceso administrativo empleando ulteriormente la informaci\u00f3n de credenciales para la cuenta Supervisor/Administrator."
}
],
"id": "CVE-2017-17974",
"lastModified": "2025-04-20T01:37:25.860",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": true,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2017-12-29T21:29:00.237",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "http://misteralfa-hack.blogspot.cl/2017/12/ba-system-improper-access-control.html"
},
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
],
"url": "https://github.com/ezelf/baCK_system"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "http://misteralfa-hack.blogspot.cl/2017/12/ba-system-improper-access-control.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://github.com/ezelf/baCK_system"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
CVE-2017-17974 (GCVE-0-2017-17974)
Vulnerability from cvelistv5 – Published: 2017-12-29 21:00 – Updated: 2024-09-17 02:27
VLAI?
Summary
BA SYSTEMS BAS Web on BAS920 devices (with Firmware 01.01.00*, HTTPserv 00002, and Script 02.*) and ISC2000 devices allows remote attackers to obtain sensitive information via a request for isc/get_sid_js.aspx or isc/get_sid.aspx, as demonstrated by obtaining administrative access by subsequently using the credential information for the Supervisor/Administrator account.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T21:06:49.959Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://misteralfa-hack.blogspot.cl/2017/12/ba-system-improper-access-control.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://github.com/ezelf/baCK_system"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "BA SYSTEMS BAS Web on BAS920 devices (with Firmware 01.01.00*, HTTPserv 00002, and Script 02.*) and ISC2000 devices allows remote attackers to obtain sensitive information via a request for isc/get_sid_js.aspx or isc/get_sid.aspx, as demonstrated by obtaining administrative access by subsequently using the credential information for the Supervisor/Administrator account."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-12-29T21:00:00Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "http://misteralfa-hack.blogspot.cl/2017/12/ba-system-improper-access-control.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/ezelf/baCK_system"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2017-17974",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "BA SYSTEMS BAS Web on BAS920 devices (with Firmware 01.01.00*, HTTPserv 00002, and Script 02.*) and ISC2000 devices allows remote attackers to obtain sensitive information via a request for isc/get_sid_js.aspx or isc/get_sid.aspx, as demonstrated by obtaining administrative access by subsequently using the credential information for the Supervisor/Administrator account."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://misteralfa-hack.blogspot.cl/2017/12/ba-system-improper-access-control.html",
"refsource": "MISC",
"url": "http://misteralfa-hack.blogspot.cl/2017/12/ba-system-improper-access-control.html"
},
{
"name": "https://github.com/ezelf/baCK_system",
"refsource": "MISC",
"url": "https://github.com/ezelf/baCK_system"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2017-17974",
"datePublished": "2017-12-29T21:00:00Z",
"dateReserved": "2017-12-29T00:00:00Z",
"dateUpdated": "2024-09-17T02:27:43.984Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-17974 (GCVE-0-2017-17974)
Vulnerability from nvd – Published: 2017-12-29 21:00 – Updated: 2024-09-17 02:27
VLAI?
Summary
BA SYSTEMS BAS Web on BAS920 devices (with Firmware 01.01.00*, HTTPserv 00002, and Script 02.*) and ISC2000 devices allows remote attackers to obtain sensitive information via a request for isc/get_sid_js.aspx or isc/get_sid.aspx, as demonstrated by obtaining administrative access by subsequently using the credential information for the Supervisor/Administrator account.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T21:06:49.959Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://misteralfa-hack.blogspot.cl/2017/12/ba-system-improper-access-control.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://github.com/ezelf/baCK_system"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "BA SYSTEMS BAS Web on BAS920 devices (with Firmware 01.01.00*, HTTPserv 00002, and Script 02.*) and ISC2000 devices allows remote attackers to obtain sensitive information via a request for isc/get_sid_js.aspx or isc/get_sid.aspx, as demonstrated by obtaining administrative access by subsequently using the credential information for the Supervisor/Administrator account."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-12-29T21:00:00Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "http://misteralfa-hack.blogspot.cl/2017/12/ba-system-improper-access-control.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/ezelf/baCK_system"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2017-17974",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "BA SYSTEMS BAS Web on BAS920 devices (with Firmware 01.01.00*, HTTPserv 00002, and Script 02.*) and ISC2000 devices allows remote attackers to obtain sensitive information via a request for isc/get_sid_js.aspx or isc/get_sid.aspx, as demonstrated by obtaining administrative access by subsequently using the credential information for the Supervisor/Administrator account."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://misteralfa-hack.blogspot.cl/2017/12/ba-system-improper-access-control.html",
"refsource": "MISC",
"url": "http://misteralfa-hack.blogspot.cl/2017/12/ba-system-improper-access-control.html"
},
{
"name": "https://github.com/ezelf/baCK_system",
"refsource": "MISC",
"url": "https://github.com/ezelf/baCK_system"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2017-17974",
"datePublished": "2017-12-29T21:00:00Z",
"dateReserved": "2017-12-29T00:00:00Z",
"dateUpdated": "2024-09-17T02:27:43.984Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}