Search criteria
10 vulnerabilities found for bizhub series by KONICA MINOLTA, INC.
CVE-2021-20872 (GCVE-0-2021-20872)
Vulnerability from cvelistv5 – Published: 2022-01-04 03:05 – Updated: 2024-08-03 17:53
VLAI?
Summary
Protection mechanism failure vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, bizhub 4752/4052 GC9-X4 and earlier) allows a physical attacker to bypass the firmware integrity verification and to install malicious firmware.
Severity ?
No CVSS data available.
CWE
- Protection mechanism failure
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| KONICA MINOLTA, INC. | bizhub series |
Affected:
bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C3851FS/C385 ...[truncated*]
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:53:23.090Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "bizhub series",
"vendor": "KONICA MINOLTA, INC.",
"versions": [
{
"status": "affected",
"version": "bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C3851FS/C385 ...[truncated*]"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Protection mechanism failure vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, bizhub 4752/4052 GC9-X4 and earlier) allows a physical attacker to bypass the firmware integrity verification and to install malicious firmware."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Protection mechanism failure",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-01-04T03:05:27",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
],
"x_ConverterErrors": {
"version_name": {
"error": "version_name too long. Use array of versions to record more than one version.",
"message": "Truncated!"
}
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vultures@jpcert.or.jp",
"ID": "CVE-2021-20872",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "bizhub series",
"version": {
"version_data": [
{
"version_value": "bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, bizhub 4752/4052 GC9-X4 and earlier"
}
]
}
}
]
},
"vendor_name": "KONICA MINOLTA, INC."
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Protection mechanism failure vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, bizhub 4752/4052 GC9-X4 and earlier) allows a physical attacker to bypass the firmware integrity verification and to install malicious firmware."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Protection mechanism failure"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html",
"refsource": "MISC",
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"name": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html",
"refsource": "MISC",
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"name": "https://jvn.jp/en/vu/JVNVU95192472/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"name": "https://jvn.jp/vu/JVNVU95192472/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2021-20872",
"datePublished": "2022-01-04T03:05:27",
"dateReserved": "2020-12-17T00:00:00",
"dateUpdated": "2024-08-03T17:53:23.090Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-20871 (GCVE-0-2021-20871)
Vulnerability from cvelistv5 – Published: 2022-01-04 03:05 – Updated: 2024-08-03 17:53
VLAI?
Summary
Exposure of sensitive information to an unauthorized actor vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier) allows an attacker on the adjacent network to obtain the credentials if the destination information including credentials are registered in the address book via a specific SOAP message.
Severity ?
No CVSS data available.
CWE
- Exposure of sensitive information to an unauthorized actor
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| KONICA MINOLTA, INC. | bizhub series |
Affected:
bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350 ...[truncated*]
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:53:22.675Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "bizhub series",
"vendor": "KONICA MINOLTA, INC.",
"versions": [
{
"status": "affected",
"version": "bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350 ...[truncated*]"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Exposure of sensitive information to an unauthorized actor vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier) allows an attacker on the adjacent network to obtain the credentials if the destination information including credentials are registered in the address book via a specific SOAP message."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Exposure of sensitive information to an unauthorized actor",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-01-04T03:05:25",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
],
"x_ConverterErrors": {
"version_name": {
"error": "version_name too long. Use array of versions to record more than one version.",
"message": "Truncated!"
}
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vultures@jpcert.or.jp",
"ID": "CVE-2021-20871",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "bizhub series",
"version": {
"version_data": [
{
"version_value": "bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier"
}
]
}
}
]
},
"vendor_name": "KONICA MINOLTA, INC."
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Exposure of sensitive information to an unauthorized actor vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier) allows an attacker on the adjacent network to obtain the credentials if the destination information including credentials are registered in the address book via a specific SOAP message."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Exposure of sensitive information to an unauthorized actor"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html",
"refsource": "MISC",
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"name": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html",
"refsource": "MISC",
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"name": "https://jvn.jp/en/vu/JVNVU95192472/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"name": "https://jvn.jp/vu/JVNVU95192472/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2021-20871",
"datePublished": "2022-01-04T03:05:25",
"dateReserved": "2020-12-17T00:00:00",
"dateUpdated": "2024-08-03T17:53:22.675Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-20870 (GCVE-0-2021-20870)
Vulnerability from cvelistv5 – Published: 2022-01-04 03:05 – Updated: 2024-08-03 17:53
VLAI?
Summary
Improper handling of exceptional conditions vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, bizhub 4752/4052 GC9-X4 and earlier, bizhub C3850/C3350/3850FS, bizhub 4750/4050, bizhub C3110, bizhub C3100P) allows a physical attacker to obtain unsent scanned image data when scanned data transmission is stopped due to the network error by ejecting a HDD before the scan job times out.
Severity ?
No CVSS data available.
CWE
- Improper handling of exceptional conditions
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| KONICA MINOLTA, INC. | bizhub series |
Affected:
bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350 ...[truncated*]
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:53:23.136Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "bizhub series",
"vendor": "KONICA MINOLTA, INC.",
"versions": [
{
"status": "affected",
"version": "bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350 ...[truncated*]"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper handling of exceptional conditions vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, bizhub 4752/4052 GC9-X4 and earlier, bizhub C3850/C3350/3850FS, bizhub 4750/4050, bizhub C3110, bizhub C3100P) allows a physical attacker to obtain unsent scanned image data when scanned data transmission is stopped due to the network error by ejecting a HDD before the scan job times out."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Improper handling of exceptional conditions",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-01-04T03:05:24",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
],
"x_ConverterErrors": {
"version_name": {
"error": "version_name too long. Use array of versions to record more than one version.",
"message": "Truncated!"
}
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vultures@jpcert.or.jp",
"ID": "CVE-2021-20870",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "bizhub series",
"version": {
"version_data": [
{
"version_value": "bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, bizhub 4752/4052 GC9-X4 and earlier, bizhub C3850/C3350/3850FS, bizhub 4750/4050, bizhub C3110, bizhub C3100P"
}
]
}
}
]
},
"vendor_name": "KONICA MINOLTA, INC."
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Improper handling of exceptional conditions vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, bizhub 4752/4052 GC9-X4 and earlier, bizhub C3850/C3350/3850FS, bizhub 4750/4050, bizhub C3110, bizhub C3100P) allows a physical attacker to obtain unsent scanned image data when scanned data transmission is stopped due to the network error by ejecting a HDD before the scan job times out."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Improper handling of exceptional conditions"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html",
"refsource": "MISC",
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"name": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html",
"refsource": "MISC",
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"name": "https://jvn.jp/en/vu/JVNVU95192472/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"name": "https://jvn.jp/vu/JVNVU95192472/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2021-20870",
"datePublished": "2022-01-04T03:05:24",
"dateReserved": "2020-12-17T00:00:00",
"dateUpdated": "2024-08-03T17:53:23.136Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-20869 (GCVE-0-2021-20869)
Vulnerability from cvelistv5 – Published: 2022-01-04 03:05 – Updated: 2024-08-03 17:53
VLAI?
Summary
Exposure of sensitive information to an unauthorized actor vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier) allows an attacker on the adjacent network to obtain some of user credentials if LDAP server authentication is enabled via a specific SOAP message.
Severity ?
No CVSS data available.
CWE
- Exposure of sensitive information to an unauthorized actor
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| KONICA MINOLTA, INC. | bizhub series |
Affected:
bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350 ...[truncated*]
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:53:22.996Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "bizhub series",
"vendor": "KONICA MINOLTA, INC.",
"versions": [
{
"status": "affected",
"version": "bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350 ...[truncated*]"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Exposure of sensitive information to an unauthorized actor vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier) allows an attacker on the adjacent network to obtain some of user credentials if LDAP server authentication is enabled via a specific SOAP message."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Exposure of sensitive information to an unauthorized actor",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-01-04T03:05:22",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
],
"x_ConverterErrors": {
"version_name": {
"error": "version_name too long. Use array of versions to record more than one version.",
"message": "Truncated!"
}
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vultures@jpcert.or.jp",
"ID": "CVE-2021-20869",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "bizhub series",
"version": {
"version_data": [
{
"version_value": "bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier"
}
]
}
}
]
},
"vendor_name": "KONICA MINOLTA, INC."
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Exposure of sensitive information to an unauthorized actor vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier) allows an attacker on the adjacent network to obtain some of user credentials if LDAP server authentication is enabled via a specific SOAP message."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Exposure of sensitive information to an unauthorized actor"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html",
"refsource": "MISC",
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"name": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html",
"refsource": "MISC",
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"name": "https://jvn.jp/en/vu/JVNVU95192472/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"name": "https://jvn.jp/vu/JVNVU95192472/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2021-20869",
"datePublished": "2022-01-04T03:05:22",
"dateReserved": "2020-12-17T00:00:00",
"dateUpdated": "2024-08-03T17:53:22.996Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-20868 (GCVE-0-2021-20868)
Vulnerability from cvelistv5 – Published: 2022-01-04 03:05 – Updated: 2024-08-03 17:53
VLAI?
Summary
Incorrect authorization vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier) allows an attacker on the adjacent network to obtain user credentials if external server authentication is enabled via a specific SOAP message sent by an administrative user.
Severity ?
No CVSS data available.
CWE
- Incorrect authorization
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| KONICA MINOLTA, INC. | bizhub series |
Affected:
bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350 ...[truncated*]
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:53:23.012Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "bizhub series",
"vendor": "KONICA MINOLTA, INC.",
"versions": [
{
"status": "affected",
"version": "bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350 ...[truncated*]"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Incorrect authorization vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier) allows an attacker on the adjacent network to obtain user credentials if external server authentication is enabled via a specific SOAP message sent by an administrative user."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Incorrect authorization",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-01-04T03:05:20",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
],
"x_ConverterErrors": {
"version_name": {
"error": "version_name too long. Use array of versions to record more than one version.",
"message": "Truncated!"
}
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vultures@jpcert.or.jp",
"ID": "CVE-2021-20868",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "bizhub series",
"version": {
"version_data": [
{
"version_value": "bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier"
}
]
}
}
]
},
"vendor_name": "KONICA MINOLTA, INC."
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Incorrect authorization vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier) allows an attacker on the adjacent network to obtain user credentials if external server authentication is enabled via a specific SOAP message sent by an administrative user."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Incorrect authorization"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html",
"refsource": "MISC",
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"name": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html",
"refsource": "MISC",
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"name": "https://jvn.jp/en/vu/JVNVU95192472/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"name": "https://jvn.jp/vu/JVNVU95192472/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2021-20868",
"datePublished": "2022-01-04T03:05:20",
"dateReserved": "2020-12-17T00:00:00",
"dateUpdated": "2024-08-03T17:53:23.012Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-20872 (GCVE-0-2021-20872)
Vulnerability from nvd – Published: 2022-01-04 03:05 – Updated: 2024-08-03 17:53
VLAI?
Summary
Protection mechanism failure vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, bizhub 4752/4052 GC9-X4 and earlier) allows a physical attacker to bypass the firmware integrity verification and to install malicious firmware.
Severity ?
No CVSS data available.
CWE
- Protection mechanism failure
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| KONICA MINOLTA, INC. | bizhub series |
Affected:
bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C3851FS/C385 ...[truncated*]
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:53:23.090Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "bizhub series",
"vendor": "KONICA MINOLTA, INC.",
"versions": [
{
"status": "affected",
"version": "bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C3851FS/C385 ...[truncated*]"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Protection mechanism failure vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, bizhub 4752/4052 GC9-X4 and earlier) allows a physical attacker to bypass the firmware integrity verification and to install malicious firmware."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Protection mechanism failure",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-01-04T03:05:27",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
],
"x_ConverterErrors": {
"version_name": {
"error": "version_name too long. Use array of versions to record more than one version.",
"message": "Truncated!"
}
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vultures@jpcert.or.jp",
"ID": "CVE-2021-20872",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "bizhub series",
"version": {
"version_data": [
{
"version_value": "bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, bizhub 4752/4052 GC9-X4 and earlier"
}
]
}
}
]
},
"vendor_name": "KONICA MINOLTA, INC."
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Protection mechanism failure vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, bizhub 4752/4052 GC9-X4 and earlier) allows a physical attacker to bypass the firmware integrity verification and to install malicious firmware."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Protection mechanism failure"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html",
"refsource": "MISC",
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"name": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html",
"refsource": "MISC",
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"name": "https://jvn.jp/en/vu/JVNVU95192472/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"name": "https://jvn.jp/vu/JVNVU95192472/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2021-20872",
"datePublished": "2022-01-04T03:05:27",
"dateReserved": "2020-12-17T00:00:00",
"dateUpdated": "2024-08-03T17:53:23.090Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-20871 (GCVE-0-2021-20871)
Vulnerability from nvd – Published: 2022-01-04 03:05 – Updated: 2024-08-03 17:53
VLAI?
Summary
Exposure of sensitive information to an unauthorized actor vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier) allows an attacker on the adjacent network to obtain the credentials if the destination information including credentials are registered in the address book via a specific SOAP message.
Severity ?
No CVSS data available.
CWE
- Exposure of sensitive information to an unauthorized actor
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| KONICA MINOLTA, INC. | bizhub series |
Affected:
bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350 ...[truncated*]
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:53:22.675Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "bizhub series",
"vendor": "KONICA MINOLTA, INC.",
"versions": [
{
"status": "affected",
"version": "bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350 ...[truncated*]"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Exposure of sensitive information to an unauthorized actor vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier) allows an attacker on the adjacent network to obtain the credentials if the destination information including credentials are registered in the address book via a specific SOAP message."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Exposure of sensitive information to an unauthorized actor",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-01-04T03:05:25",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
],
"x_ConverterErrors": {
"version_name": {
"error": "version_name too long. Use array of versions to record more than one version.",
"message": "Truncated!"
}
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vultures@jpcert.or.jp",
"ID": "CVE-2021-20871",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "bizhub series",
"version": {
"version_data": [
{
"version_value": "bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier"
}
]
}
}
]
},
"vendor_name": "KONICA MINOLTA, INC."
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Exposure of sensitive information to an unauthorized actor vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier) allows an attacker on the adjacent network to obtain the credentials if the destination information including credentials are registered in the address book via a specific SOAP message."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Exposure of sensitive information to an unauthorized actor"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html",
"refsource": "MISC",
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"name": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html",
"refsource": "MISC",
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"name": "https://jvn.jp/en/vu/JVNVU95192472/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"name": "https://jvn.jp/vu/JVNVU95192472/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2021-20871",
"datePublished": "2022-01-04T03:05:25",
"dateReserved": "2020-12-17T00:00:00",
"dateUpdated": "2024-08-03T17:53:22.675Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-20870 (GCVE-0-2021-20870)
Vulnerability from nvd – Published: 2022-01-04 03:05 – Updated: 2024-08-03 17:53
VLAI?
Summary
Improper handling of exceptional conditions vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, bizhub 4752/4052 GC9-X4 and earlier, bizhub C3850/C3350/3850FS, bizhub 4750/4050, bizhub C3110, bizhub C3100P) allows a physical attacker to obtain unsent scanned image data when scanned data transmission is stopped due to the network error by ejecting a HDD before the scan job times out.
Severity ?
No CVSS data available.
CWE
- Improper handling of exceptional conditions
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| KONICA MINOLTA, INC. | bizhub series |
Affected:
bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350 ...[truncated*]
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:53:23.136Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "bizhub series",
"vendor": "KONICA MINOLTA, INC.",
"versions": [
{
"status": "affected",
"version": "bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350 ...[truncated*]"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper handling of exceptional conditions vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, bizhub 4752/4052 GC9-X4 and earlier, bizhub C3850/C3350/3850FS, bizhub 4750/4050, bizhub C3110, bizhub C3100P) allows a physical attacker to obtain unsent scanned image data when scanned data transmission is stopped due to the network error by ejecting a HDD before the scan job times out."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Improper handling of exceptional conditions",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-01-04T03:05:24",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
],
"x_ConverterErrors": {
"version_name": {
"error": "version_name too long. Use array of versions to record more than one version.",
"message": "Truncated!"
}
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vultures@jpcert.or.jp",
"ID": "CVE-2021-20870",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "bizhub series",
"version": {
"version_data": [
{
"version_value": "bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, bizhub 4752/4052 GC9-X4 and earlier, bizhub C3850/C3350/3850FS, bizhub 4750/4050, bizhub C3110, bizhub C3100P"
}
]
}
}
]
},
"vendor_name": "KONICA MINOLTA, INC."
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Improper handling of exceptional conditions vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, bizhub 4752/4052 GC9-X4 and earlier, bizhub C3850/C3350/3850FS, bizhub 4750/4050, bizhub C3110, bizhub C3100P) allows a physical attacker to obtain unsent scanned image data when scanned data transmission is stopped due to the network error by ejecting a HDD before the scan job times out."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Improper handling of exceptional conditions"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html",
"refsource": "MISC",
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"name": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html",
"refsource": "MISC",
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"name": "https://jvn.jp/en/vu/JVNVU95192472/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"name": "https://jvn.jp/vu/JVNVU95192472/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2021-20870",
"datePublished": "2022-01-04T03:05:24",
"dateReserved": "2020-12-17T00:00:00",
"dateUpdated": "2024-08-03T17:53:23.136Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-20869 (GCVE-0-2021-20869)
Vulnerability from nvd – Published: 2022-01-04 03:05 – Updated: 2024-08-03 17:53
VLAI?
Summary
Exposure of sensitive information to an unauthorized actor vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier) allows an attacker on the adjacent network to obtain some of user credentials if LDAP server authentication is enabled via a specific SOAP message.
Severity ?
No CVSS data available.
CWE
- Exposure of sensitive information to an unauthorized actor
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| KONICA MINOLTA, INC. | bizhub series |
Affected:
bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350 ...[truncated*]
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:53:22.996Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "bizhub series",
"vendor": "KONICA MINOLTA, INC.",
"versions": [
{
"status": "affected",
"version": "bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350 ...[truncated*]"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Exposure of sensitive information to an unauthorized actor vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier) allows an attacker on the adjacent network to obtain some of user credentials if LDAP server authentication is enabled via a specific SOAP message."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Exposure of sensitive information to an unauthorized actor",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-01-04T03:05:22",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
],
"x_ConverterErrors": {
"version_name": {
"error": "version_name too long. Use array of versions to record more than one version.",
"message": "Truncated!"
}
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vultures@jpcert.or.jp",
"ID": "CVE-2021-20869",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "bizhub series",
"version": {
"version_data": [
{
"version_value": "bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier"
}
]
}
}
]
},
"vendor_name": "KONICA MINOLTA, INC."
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Exposure of sensitive information to an unauthorized actor vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier) allows an attacker on the adjacent network to obtain some of user credentials if LDAP server authentication is enabled via a specific SOAP message."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Exposure of sensitive information to an unauthorized actor"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html",
"refsource": "MISC",
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"name": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html",
"refsource": "MISC",
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"name": "https://jvn.jp/en/vu/JVNVU95192472/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"name": "https://jvn.jp/vu/JVNVU95192472/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2021-20869",
"datePublished": "2022-01-04T03:05:22",
"dateReserved": "2020-12-17T00:00:00",
"dateUpdated": "2024-08-03T17:53:22.996Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-20868 (GCVE-0-2021-20868)
Vulnerability from nvd – Published: 2022-01-04 03:05 – Updated: 2024-08-03 17:53
VLAI?
Summary
Incorrect authorization vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier) allows an attacker on the adjacent network to obtain user credentials if external server authentication is enabled via a specific SOAP message sent by an administrative user.
Severity ?
No CVSS data available.
CWE
- Incorrect authorization
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| KONICA MINOLTA, INC. | bizhub series |
Affected:
bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350 ...[truncated*]
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:53:23.012Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "bizhub series",
"vendor": "KONICA MINOLTA, INC.",
"versions": [
{
"status": "affected",
"version": "bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350 ...[truncated*]"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Incorrect authorization vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier) allows an attacker on the adjacent network to obtain user credentials if external server authentication is enabled via a specific SOAP message sent by an administrative user."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Incorrect authorization",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-01-04T03:05:20",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
],
"x_ConverterErrors": {
"version_name": {
"error": "version_name too long. Use array of versions to record more than one version.",
"message": "Truncated!"
}
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vultures@jpcert.or.jp",
"ID": "CVE-2021-20868",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "bizhub series",
"version": {
"version_data": [
{
"version_value": "bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier"
}
]
}
}
]
},
"vendor_name": "KONICA MINOLTA, INC."
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Incorrect authorization vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier) allows an attacker on the adjacent network to obtain user credentials if external server authentication is enabled via a specific SOAP message sent by an administrative user."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Incorrect authorization"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html",
"refsource": "MISC",
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"name": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html",
"refsource": "MISC",
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"name": "https://jvn.jp/en/vu/JVNVU95192472/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"name": "https://jvn.jp/vu/JVNVU95192472/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2021-20868",
"datePublished": "2022-01-04T03:05:20",
"dateReserved": "2020-12-17T00:00:00",
"dateUpdated": "2024-08-03T17:53:23.012Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",