All the vulnerabilites related to siemens - cp100_firmware
cve-2018-11452
Vulnerability from cvelistv5
Published
2018-07-23 21:00
Modified
2024-08-05 08:10
Severity ?
Summary
A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module (All versions < V4.33), Firmware variant PROFINET IO for EN100 Ethernet module (All versions), Firmware variant Modbus TCP for EN100 Ethernet module (All versions), Firmware variant DNP3 TCP for EN100 Ethernet module (All versions), Firmware variant IEC104 for EN100 Ethernet module (All versions < V1.22). Specially crafted packets to port 102/tcp could cause a denial-of-service condition in the EN100 communication module if oscillographs are running. A manual restart is required to recover the EN100 module functionality. Successful exploitation requires an attacker with network access to send multiple packets to the EN100 module. As a precondition the IEC 61850-MMS communication needs to be activated on the affected EN100 modules. No user interaction or privileges are required to exploit the security vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the network functionality of the device, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T08:10:14.304Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-635129.pdf"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-325546.pdf"
          },
          {
            "name": "106221",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "https://www.securityfocus.com/bid/106221"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Firmware variant IEC 61850 for EN100 Ethernet module",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.33"
            }
          ]
        },
        {
          "product": "Firmware variant PROFINET IO for EN100 Ethernet module",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "Firmware variant Modbus TCP for EN100 Ethernet module",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "Firmware variant DNP3 TCP for EN100 Ethernet module",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "Firmware variant IEC104 for EN100 Ethernet module",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.22"
            }
          ]
        }
      ],
      "datePublic": "2018-07-11T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module (All versions \u003c V4.33), Firmware variant PROFINET IO for EN100 Ethernet module (All versions), Firmware variant Modbus TCP for EN100 Ethernet module (All versions), Firmware variant DNP3 TCP for EN100 Ethernet module (All versions), Firmware variant IEC104 for EN100 Ethernet module (All versions \u003c V1.22). Specially crafted packets to port 102/tcp could cause a denial-of-service condition in the EN100 communication module if oscillographs are running. A manual restart is required to recover the EN100 module functionality. Successful exploitation requires an attacker with network access to send multiple packets to the EN100 module. As a precondition the IEC 61850-MMS communication needs to be activated on the affected EN100 modules. No user interaction or privileges are required to exploit the security vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the network functionality of the device, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Other",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-03-22T16:55:20",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-635129.pdf"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-325546.pdf"
        },
        {
          "name": "106221",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "https://www.securityfocus.com/bid/106221"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2018-11452",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Firmware variant IEC 61850 for EN100 Ethernet module",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.33"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Firmware variant PROFINET IO for EN100 Ethernet module",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Firmware variant Modbus TCP for EN100 Ethernet module",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Firmware variant DNP3 TCP for EN100 Ethernet module",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Firmware variant IEC104 for EN100 Ethernet module",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V1.22"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module (All versions \u003c V4.33), Firmware variant PROFINET IO for EN100 Ethernet module (All versions), Firmware variant Modbus TCP for EN100 Ethernet module (All versions), Firmware variant DNP3 TCP for EN100 Ethernet module (All versions), Firmware variant IEC104 for EN100 Ethernet module (All versions \u003c V1.22). Specially crafted packets to port 102/tcp could cause a denial-of-service condition in the EN100 communication module if oscillographs are running. A manual restart is required to recover the EN100 module functionality. Successful exploitation requires an attacker with network access to send multiple packets to the EN100 module. As a precondition the IEC 61850-MMS communication needs to be activated on the affected EN100 modules. No user interaction or privileges are required to exploit the security vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the network functionality of the device, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Other"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-635129.pdf",
              "refsource": "CONFIRM",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-635129.pdf"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-325546.pdf",
              "refsource": "CONFIRM",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-325546.pdf"
            },
            {
              "name": "106221",
              "refsource": "BID",
              "url": "https://www.securityfocus.com/bid/106221"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2018-11452",
    "datePublished": "2018-07-23T21:00:00",
    "dateReserved": "2018-05-25T00:00:00",
    "dateUpdated": "2024-08-05T08:10:14.304Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2018-11451
Vulnerability from cvelistv5
Published
2018-07-23 21:00
Modified
2024-08-05 08:10
Severity ?
Summary
A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module (All versions < V4.33), Firmware variant PROFINET IO for EN100 Ethernet module (All versions), Firmware variant Modbus TCP for EN100 Ethernet module (All versions), Firmware variant DNP3 TCP for EN100 Ethernet module (All versions), Firmware variant IEC104 for EN100 Ethernet module (All versions < V1.22), SIPROTEC 5 relays with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions < V7.80), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions < V7.58). Specially crafted packets to port 102/tcp could cause a denial-of-service condition in the affected products. A manual restart is required to recover the EN100 module functionality of the affected devices. Successful exploitation requires an attacker with network access to send multiple packets to the affected products or modules. As a precondition the IEC 61850-MMS communication needs to be activated on the affected products or modules. No user interaction or privileges are required to exploit the vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the network functionality of the device, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T08:10:14.145Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-635129.pdf"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-325546.pdf"
          },
          {
            "name": "106221",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "https://www.securityfocus.com/bid/106221"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Firmware variant IEC 61850 for EN100 Ethernet module",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.33"
            }
          ]
        },
        {
          "product": "Firmware variant PROFINET IO for EN100 Ethernet module",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "Firmware variant Modbus TCP for EN100 Ethernet module",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "Firmware variant DNP3 TCP for EN100 Ethernet module",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "Firmware variant IEC104 for EN100 Ethernet module",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.22"
            }
          ]
        },
        {
          "product": "SIPROTEC 5 relays with CPU variants CP300 and CP100 and the respective Ethernet communication modules",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.80"
            }
          ]
        },
        {
          "product": "SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.58"
            }
          ]
        }
      ],
      "datePublic": "2018-07-11T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module (All versions \u003c V4.33), Firmware variant PROFINET IO for EN100 Ethernet module (All versions), Firmware variant Modbus TCP for EN100 Ethernet module (All versions), Firmware variant DNP3 TCP for EN100 Ethernet module (All versions), Firmware variant IEC104 for EN100 Ethernet module (All versions \u003c V1.22), SIPROTEC 5 relays with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions \u003c V7.80), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions \u003c V7.58). Specially crafted packets to port 102/tcp could cause a denial-of-service condition in the affected products. A manual restart is required to recover the EN100 module functionality of the affected devices. Successful exploitation requires an attacker with network access to send multiple packets to the affected products or modules. As a precondition the IEC 61850-MMS communication needs to be activated on the affected products or modules. No user interaction or privileges are required to exploit the vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the network functionality of the device, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Other",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-03-22T16:52:40",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-635129.pdf"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-325546.pdf"
        },
        {
          "name": "106221",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "https://www.securityfocus.com/bid/106221"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2018-11451",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Firmware variant IEC 61850 for EN100 Ethernet module",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.33"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Firmware variant PROFINET IO for EN100 Ethernet module",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Firmware variant Modbus TCP for EN100 Ethernet module",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Firmware variant DNP3 TCP for EN100 Ethernet module",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Firmware variant IEC104 for EN100 Ethernet module",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V1.22"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIPROTEC 5 relays with CPU variants CP300 and CP100 and the respective Ethernet communication modules",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.80"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.58"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module (All versions \u003c V4.33), Firmware variant PROFINET IO for EN100 Ethernet module (All versions), Firmware variant Modbus TCP for EN100 Ethernet module (All versions), Firmware variant DNP3 TCP for EN100 Ethernet module (All versions), Firmware variant IEC104 for EN100 Ethernet module (All versions \u003c V1.22), SIPROTEC 5 relays with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions \u003c V7.80), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions \u003c V7.58). Specially crafted packets to port 102/tcp could cause a denial-of-service condition in the affected products. A manual restart is required to recover the EN100 module functionality of the affected devices. Successful exploitation requires an attacker with network access to send multiple packets to the affected products or modules. As a precondition the IEC 61850-MMS communication needs to be activated on the affected products or modules. No user interaction or privileges are required to exploit the vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the network functionality of the device, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Other"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-635129.pdf",
              "refsource": "CONFIRM",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-635129.pdf"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-325546.pdf",
              "refsource": "CONFIRM",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-325546.pdf"
            },
            {
              "name": "106221",
              "refsource": "BID",
              "url": "https://www.securityfocus.com/bid/106221"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2018-11451",
    "datePublished": "2018-07-23T21:00:00",
    "dateReserved": "2018-05-25T00:00:00",
    "dateUpdated": "2024-08-05T08:10:14.145Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Vulnerability from fkie_nvd
Published
2018-07-23 21:29
Modified
2024-11-21 03:43
Summary
A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module (All versions < V4.33), Firmware variant PROFINET IO for EN100 Ethernet module (All versions), Firmware variant Modbus TCP for EN100 Ethernet module (All versions), Firmware variant DNP3 TCP for EN100 Ethernet module (All versions), Firmware variant IEC104 for EN100 Ethernet module (All versions < V1.22). Specially crafted packets to port 102/tcp could cause a denial-of-service condition in the EN100 communication module if oscillographs are running. A manual restart is required to recover the EN100 module functionality. Successful exploitation requires an attacker with network access to send multiple packets to the EN100 module. As a precondition the IEC 61850-MMS communication needs to be activated on the affected EN100 modules. No user interaction or privileges are required to exploit the security vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the network functionality of the device, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:dnp3_tcp_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "04A7E6F4-0372-408E-AE77-39B37D1E00DA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:iec_61850_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2A7D24E4-0AF5-499C-A775-8187BC106EC6",
              "versionEndExcluding": "4.33",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:iec104_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CEE03CFB-8608-4311-AB1F-E6D8422EA15E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:modbus_tcp_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD50B51F-7279-4C2E-8A8A-26DE222D6FEA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:profinet_io_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "58CF55F4-5089-40DF-ACE2-21A310047F75",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:en100:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "699BE849-E0F2-4DF3-9536-E5E632719C61",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cp100_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "65B58535-D1E1-4EF7-AB73-B832D914154A",
              "versionEndExcluding": "7.80",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:cp200_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C47D53A6-C320-4AC2-93D8-09191C522D0A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:cp300_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A845921A-F712-4AC5-A8FA-32D09345F001",
              "versionEndExcluding": "7.80",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6md85:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "23076116-128D-4366-B5BC-B965001FE356",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:6md86:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3457758B-A04D-4544-B0FA-DF87AA11D8FE",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7ke85:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "751F0BFE-216F-4620-BD5A-451B5F49C09C",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7sa82:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AF247CA0-37E1-40DF-96F5-9F00128EA250",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7sa86:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EDD3C99B-CDD8-4919-BE72-73814C2642A4",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7sa87:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DBE6CCA9-A246-4EB2-A57B-FE6823A9E3FD",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7sd82:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E11B4A68-F533-4AC0-80A9-7374FDFE2DEA",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7sd86:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "73F8D692-F268-45A4-9348-C67890A58881",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7sd87:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3C5A3FFD-17AD-4820-97D3-2F093BD5F322",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7sj82:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5739872A-E271-48BB-ABB5-17608E81AE7A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7sj85:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "ECC6417D-2C81-4654-B7FF-6C3E1B709962",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7sj86:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C52A6630-46F3-4113-B5E8-F5BAB7801CB0",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7sk82:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "088AC7F2-4FF3-4EF9-A111-D47DB859ECA1",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7sk85:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "73DD95AC-9B8F-43CD-9483-2BB9C4E86376",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7sl82:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8A9F05D9-C1DF-4D73-8634-239ABFE526DB",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7sl86:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C6662F7-5E3D-43A8-9984-EF1540BC917B",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7sl87:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E122323B-A42B-4DAB-A071-ACF76DC45E28",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7ss85:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5877387C-E05B-4231-9016-01FE7B197589",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7um85:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AAA9E810-2C00-4721-B3A6-E7CD7184BA24",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7ut82:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2E959A8E-21D1-4950-974B-A89693C14DC9",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7ut85:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DA075D19-21BF-4A7C-87B8-6A9D99799826",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7ut86:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7AC0D445-9A9B-4799-8B83-8B15821A6CC1",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7ut87:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D2A73860-76C5-435B-8150-1EABF644ADA0",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7vk87:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5D9FD3B7-C7F7-41C1-9290-411F9D912D00",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module (All versions \u003c V4.33), Firmware variant PROFINET IO for EN100 Ethernet module (All versions), Firmware variant Modbus TCP for EN100 Ethernet module (All versions), Firmware variant DNP3 TCP for EN100 Ethernet module (All versions), Firmware variant IEC104 for EN100 Ethernet module (All versions \u003c V1.22). Specially crafted packets to port 102/tcp could cause a denial-of-service condition in the EN100 communication module if oscillographs are running. A manual restart is required to recover the EN100 module functionality. Successful exploitation requires an attacker with network access to send multiple packets to the EN100 module. As a precondition the IEC 61850-MMS communication needs to be activated on the affected EN100 modules. No user interaction or privileges are required to exploit the security vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the network functionality of the device, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en la variante de firmware IEC 61850 para el m\u00f3dulo de Ethernet EN100 (todas las versiones anteriores a la V4.33), la variante de firmware PROFINET IO para el m\u00f3dulo de Ethernet EN100 (todas las versiones), la variante de firmware Modbus TCP para el m\u00f3dulo de Ethernet EN100 (todas las versiones), la variante de firmware DNP3 TCP para el m\u00f3dulo de Ethernet EN100 (todas las versiones) y la variante de firmware IEC104 para el m\u00f3dulo de Ethernet EN100 (todas las versiones anteriores a la V1.22). Los paquetes especialmente manipulados enviados al puerto 102/tcp podr\u00edan provocar una denegaci\u00f3n de servicio (DoS) en el m\u00f3dulo de comunicaciones EN100 si los osciloscopios se est\u00e1n ejecutando. Se necesita un reinicio manual para recuperar la funcionalidad del m\u00f3dulo EN100. Su explotaci\u00f3n con \u00e9xito requiere que un atacante con acceso de red env\u00ede m\u00faltiples paquetes al m\u00f3dulo EN100. Como prerrequisito, la comunicaci\u00f3n IEC 61850-MMS necesita activarse en los m\u00f3dulos EN100 afectados. No se requiere interacci\u00f3n o privilegios del usuario para explotar esta vulnerabilidad de seguridad. La vulnerabilidad podr\u00eda permitir una denegaci\u00f3n de servicio (DoS) en la funcionalidad de red del dispositivo, comprometiendo la disponibilidad del sistema. En el momento de la publicaci\u00f3n del advisory, no se conoce ninguna explotaci\u00f3n p\u00fablica de la vulnerabilidad de seguridad."
    }
  ],
  "id": "CVE-2018-11452",
  "lastModified": "2024-11-21T03:43:23.857",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 7.8,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2018-07-23T21:29:00.283",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Mitigation",
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-325546.pdf"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Mitigation",
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-635129.pdf"
    },
    {
      "source": "productcert@siemens.com",
      "url": "https://www.securityfocus.com/bid/106221"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mitigation",
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-325546.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mitigation",
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-635129.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://www.securityfocus.com/bid/106221"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-20"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2018-07-23 21:29
Modified
2024-11-21 03:43
Summary
A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module (All versions < V4.33), Firmware variant PROFINET IO for EN100 Ethernet module (All versions), Firmware variant Modbus TCP for EN100 Ethernet module (All versions), Firmware variant DNP3 TCP for EN100 Ethernet module (All versions), Firmware variant IEC104 for EN100 Ethernet module (All versions < V1.22), SIPROTEC 5 relays with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions < V7.80), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions < V7.58). Specially crafted packets to port 102/tcp could cause a denial-of-service condition in the affected products. A manual restart is required to recover the EN100 module functionality of the affected devices. Successful exploitation requires an attacker with network access to send multiple packets to the affected products or modules. As a precondition the IEC 61850-MMS communication needs to be activated on the affected products or modules. No user interaction or privileges are required to exploit the vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the network functionality of the device, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:dnp3_tcp_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "04A7E6F4-0372-408E-AE77-39B37D1E00DA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:iec_61850_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2A7D24E4-0AF5-499C-A775-8187BC106EC6",
              "versionEndExcluding": "4.33",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:iec104_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CEE03CFB-8608-4311-AB1F-E6D8422EA15E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:modbus_tcp_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD50B51F-7279-4C2E-8A8A-26DE222D6FEA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:profinet_io_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "58CF55F4-5089-40DF-ACE2-21A310047F75",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:en100:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "699BE849-E0F2-4DF3-9536-E5E632719C61",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cp100_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "65B58535-D1E1-4EF7-AB73-B832D914154A",
              "versionEndExcluding": "7.80",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:cp200_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C47D53A6-C320-4AC2-93D8-09191C522D0A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:cp300_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A845921A-F712-4AC5-A8FA-32D09345F001",
              "versionEndExcluding": "7.80",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6md85:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "23076116-128D-4366-B5BC-B965001FE356",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:6md86:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3457758B-A04D-4544-B0FA-DF87AA11D8FE",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7ke85:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "751F0BFE-216F-4620-BD5A-451B5F49C09C",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7sa82:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AF247CA0-37E1-40DF-96F5-9F00128EA250",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7sa86:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EDD3C99B-CDD8-4919-BE72-73814C2642A4",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7sa87:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DBE6CCA9-A246-4EB2-A57B-FE6823A9E3FD",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7sd82:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E11B4A68-F533-4AC0-80A9-7374FDFE2DEA",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7sd86:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "73F8D692-F268-45A4-9348-C67890A58881",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7sd87:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3C5A3FFD-17AD-4820-97D3-2F093BD5F322",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7sj82:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5739872A-E271-48BB-ABB5-17608E81AE7A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7sj85:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "ECC6417D-2C81-4654-B7FF-6C3E1B709962",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7sj86:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C52A6630-46F3-4113-B5E8-F5BAB7801CB0",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7sk82:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "088AC7F2-4FF3-4EF9-A111-D47DB859ECA1",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7sk85:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "73DD95AC-9B8F-43CD-9483-2BB9C4E86376",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7sl82:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8A9F05D9-C1DF-4D73-8634-239ABFE526DB",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7sl86:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C6662F7-5E3D-43A8-9984-EF1540BC917B",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7sl87:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E122323B-A42B-4DAB-A071-ACF76DC45E28",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7ss85:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5877387C-E05B-4231-9016-01FE7B197589",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7um85:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AAA9E810-2C00-4721-B3A6-E7CD7184BA24",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7ut82:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2E959A8E-21D1-4950-974B-A89693C14DC9",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7ut85:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DA075D19-21BF-4A7C-87B8-6A9D99799826",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7ut86:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7AC0D445-9A9B-4799-8B83-8B15821A6CC1",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7ut87:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D2A73860-76C5-435B-8150-1EABF644ADA0",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7vk87:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5D9FD3B7-C7F7-41C1-9290-411F9D912D00",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module (All versions \u003c V4.33), Firmware variant PROFINET IO for EN100 Ethernet module (All versions), Firmware variant Modbus TCP for EN100 Ethernet module (All versions), Firmware variant DNP3 TCP for EN100 Ethernet module (All versions), Firmware variant IEC104 for EN100 Ethernet module (All versions \u003c V1.22), SIPROTEC 5 relays with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions \u003c V7.80), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions \u003c V7.58). Specially crafted packets to port 102/tcp could cause a denial-of-service condition in the affected products. A manual restart is required to recover the EN100 module functionality of the affected devices. Successful exploitation requires an attacker with network access to send multiple packets to the affected products or modules. As a precondition the IEC 61850-MMS communication needs to be activated on the affected products or modules. No user interaction or privileges are required to exploit the vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the network functionality of the device, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en la variante de firmware IEC 61850 para el m\u00f3dulo de Ethernet EN100 (todas las versiones anteriores a la V4.33), la variante de firmware PROFINET IO para el m\u00f3dulo de Ethernet EN100 (todas las versiones), la variante de firmware Modbus TCP para el m\u00f3dulo de Ethernet EN100 (todas las versiones), la variante de firmware DNP3 TCP para el m\u00f3dulo de Ethernet EN100 (todas las versiones), la variante de firmware IEC104b para el m\u00f3dulo de Ethernet EN100 (todas las versiones anteriores a la V7.80), los relays SIPROTEC 5 con las variantes de CPU CP300 y CP100 y los respectivos m\u00f3dulos de comunicaci\u00f3n Ethernet (todas las versiones anteriores a la V7.80) y los relays SIPROTEC 5 con las variantes de CPU CP200 y los respectivos m\u00f3dulos de comunicaci\u00f3n Ethernet (todas las versiones anteriores a la V7.58). Los paquetes especialmente manipulados enviados al puerto 102/tcp podr\u00edan provocar una denegaci\u00f3n de servicio (DoS) en los productos afectados. Se necesita un reinicio manual para recuperar la funcionalidad del m\u00f3dulo EN100 de los dispositivos afectados. Su explotaci\u00f3n con \u00e9xito requiere que un atacante con acceso de red env\u00ede m\u00faltiples paquetes a los productos o m\u00f3dulos afectados. Como prerrequisito, la comunicaci\u00f3n IEC 61850-MMS necesita activarse en los productos o m\u00f3dulos afectados. No se requiere interacci\u00f3n o privilegios del usuario para explotar esta vulnerabilidad. La vulnerabilidad podr\u00eda permitir una denegaci\u00f3n de servicio (DoS) en la funcionalidad de red del dispositivo, comprometiendo la disponibilidad del sistema. En el momento de la publicaci\u00f3n del advisory, no se conoce ninguna explotaci\u00f3n p\u00fablica de la vulnerabilidad de seguridad."
    }
  ],
  "id": "CVE-2018-11451",
  "lastModified": "2024-11-21T03:43:23.707",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 7.8,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2018-07-23T21:29:00.237",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Mitigation",
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-325546.pdf"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Mitigation",
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-635129.pdf"
    },
    {
      "source": "productcert@siemens.com",
      "url": "https://www.securityfocus.com/bid/106221"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mitigation",
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-325546.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mitigation",
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-635129.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://www.securityfocus.com/bid/106221"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-20"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}