VAR-202107-0200
Vulnerability from variot - Updated: 2023-12-18 12:16Incorrect Access Control in Beckhoff Automation GmbH & Co. KG CX9020 with firmware version CX9020_CB3011_WEC7_HPS_v602_TC31_B4016.6 allows remote attackers to bypass authentication via the "CE Remote Display Tool" as it does not close the incoming connection on the Windows CE side if the credentials are incorrect. KG CX9020 There are unspecified vulnerabilities in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202107-0200",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "cx9020",
"scope": "eq",
"trust": 1.0,
"vendor": "beckhoff",
"version": "6.02"
},
{
"model": "cx9020",
"scope": "eq",
"trust": 0.8,
"vendor": "beckhoff automation",
"version": "_cb3011_wec7_hps_v602_tc31_b4016.6"
},
{
"model": "cx9020",
"scope": "eq",
"trust": 0.8,
"vendor": "beckhoff automation",
"version": null
},
{
"model": "cx9020",
"scope": null,
"trust": 0.8,
"vendor": "beckhoff automation",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-016595"
},
{
"db": "NVD",
"id": "CVE-2020-20741"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:beckhoff:cx9020:6.02:build_4016.6:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2020-20741"
}
]
},
"cve": "CVE-2020-20741",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 7.5,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2020-20741",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.9,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2020-20741",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2020-20741",
"trust": 1.8,
"value": "CRITICAL"
},
{
"author": "CNNVD",
"id": "CNNVD-202107-1797",
"trust": 0.6,
"value": "CRITICAL"
},
{
"author": "VULMON",
"id": "CVE-2020-20741",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2020-20741"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-016595"
},
{
"db": "NVD",
"id": "CVE-2020-20741"
},
{
"db": "CNNVD",
"id": "CNNVD-202107-1797"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Incorrect Access Control in Beckhoff Automation GmbH \u0026 Co. KG CX9020 with firmware version CX9020_CB3011_WEC7_HPS_v602_TC31_B4016.6 allows remote attackers to bypass authentication via the \"CE Remote Display Tool\" as it does not close the incoming connection on the Windows CE side if the credentials are incorrect. KG CX9020 There are unspecified vulnerabilities in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2020-20741"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-016595"
},
{
"db": "VULMON",
"id": "CVE-2020-20741"
}
],
"trust": 1.71
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2020-20741",
"trust": 3.3
},
{
"db": "JVNDB",
"id": "JVNDB-2019-016595",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-202107-1797",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2020-20741",
"trust": 0.1
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2020-20741"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-016595"
},
{
"db": "NVD",
"id": "CVE-2020-20741"
},
{
"db": "CNNVD",
"id": "CNNVD-202107-1797"
}
]
},
"id": "VAR-202107-0200",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.5
},
"last_update_date": "2023-12-18T12:16:21.916000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Advisory\u00a02019-06",
"trust": 0.8,
"url": "https://download.beckhoff.com/download/document/product-security/advisories/advisory-2019-006.pdf"
},
{
"title": "Beckhoff Automation GmbH \u0026 Co. KG CX9020 Security vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=159166"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-016595"
},
{
"db": "CNNVD",
"id": "CNNVD-202107-1797"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "NVD-CWE-Other",
"trust": 1.0
},
{
"problemtype": "others (CWE-Other) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-016595"
},
{
"db": "NVD",
"id": "CVE-2020-20741"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.7,
"url": "https://download.beckhoff.com/download/document/product-security/advisories/advisory-2019-006.pdf"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2020-20741"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2020-20741"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-016595"
},
{
"db": "NVD",
"id": "CVE-2020-20741"
},
{
"db": "CNNVD",
"id": "CNNVD-202107-1797"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULMON",
"id": "CVE-2020-20741"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-016595"
},
{
"db": "NVD",
"id": "CVE-2020-20741"
},
{
"db": "CNNVD",
"id": "CNNVD-202107-1797"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-07-23T00:00:00",
"db": "VULMON",
"id": "CVE-2020-20741"
},
{
"date": "2022-08-16T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-016595"
},
{
"date": "2021-07-23T20:15:08.017000",
"db": "NVD",
"id": "CVE-2020-20741"
},
{
"date": "2021-07-23T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202107-1797"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-08-09T00:00:00",
"db": "VULMON",
"id": "CVE-2020-20741"
},
{
"date": "2022-08-16T02:21:00",
"db": "JVNDB",
"id": "JVNDB-2019-016595"
},
{
"date": "2021-08-09T17:43:48.367000",
"db": "NVD",
"id": "CVE-2020-20741"
},
{
"date": "2021-08-17T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202107-1797"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202107-1797"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Beckhoff\u00a0Automation\u00a0GmbH\u00a0\u0026\u00a0Co.\u00a0KG\u00a0CX9020\u00a0 Firmware vulnerabilities",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-016595"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "other",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202107-1797"
}
],
"trust": 0.6
}
}
VAR-202002-1688
Vulnerability from variot - Updated: 2022-05-04 10:21CX9020 is a PLC generated by BeckHoff. Its Webservice is used to remotely configure the PLC service. Through this service, users can configure the PLC with a browser.
BeckHoff CX9020 has a buffer overflow vulnerability that could be exploited by an attacker to crash the service or potentially execute malicious code.
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202002-1688",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "cx9020",
"scope": null,
"trust": 0.6,
"vendor": "beckhoff",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-12846"
}
]
},
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "HIGH",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 2.6,
"confidentialityImpact": "NONE",
"exploitabilityScore": 4.9,
"id": "CNVD-2020-12846",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "LOW",
"trust": 0.6,
"vectorString": "AV:N/AC:H/Au:N/C:N/I:N/A:P",
"version": "2.0"
}
],
"cvssV3": [],
"severity": [
{
"author": "CNVD",
"id": "CNVD-2020-12846",
"trust": 0.6,
"value": "LOW"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-12846"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "CX9020 is a PLC generated by BeckHoff. Its Webservice is used to remotely configure the PLC service. Through this service, users can configure the PLC with a browser.\n\r\n\r\nBeckHoff CX9020 has a buffer overflow vulnerability that could be exploited by an attacker to crash the service or potentially execute malicious code.",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-12846"
}
],
"trust": 0.6
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2020-12846",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-12846"
}
]
},
"id": "VAR-202002-1688",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-12846"
}
],
"trust": 1.1
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-12846"
}
]
},
"last_update_date": "2022-05-04T10:21:45.256000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "BeckHoff CX9020 webservice has buffer overflow vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/196853"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-12846"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2020-12846"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-02-24T00:00:00",
"db": "CNVD",
"id": "CNVD-2020-12846"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-03-17T00:00:00",
"db": "CNVD",
"id": "CNVD-2020-12846"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "BeckHoff CX9020 has a buffer overflow vulnerability",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-12846"
}
],
"trust": 0.6
}
}
FKIE_CVE-2020-20741
Vulnerability from fkie_nvd - Published: 2021-07-23 20:15 - Updated: 2024-11-21 05:12| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://download.beckhoff.com/download/Document/product-security/Advisories/advisory-2019-006.pdf | Mitigation, Patch, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://download.beckhoff.com/download/Document/product-security/Advisories/advisory-2019-006.pdf | Mitigation, Patch, Vendor Advisory |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:beckhoff:cx9020:6.02:build_4016.6:*:*:*:*:*:*",
"matchCriteriaId": "D1A3291C-B38B-4EBC-9D16-1979B5723FF2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Incorrect Access Control in Beckhoff Automation GmbH \u0026 Co. KG CX9020 with firmware version CX9020_CB3011_WEC7_HPS_v602_TC31_B4016.6 allows remote attackers to bypass authentication via the \"CE Remote Display Tool\" as it does not close the incoming connection on the Windows CE side if the credentials are incorrect."
},
{
"lang": "es",
"value": "Un Control de Acceso Incorrecto en Beckhoff Automation GmbH \u0026amp; Co. KG CX9020 con versiones de firmware CX9020_CB3011_WEC7_HPS_v602_TC31_B4016.6, permite a atacantes remotos omitir la autenticaci\u00f3n por medio de \"CE Remote Display Tool\", ya que no cierra la conexi\u00f3n entrante en el lado de Windows CE si las credenciales son incorrectas"
}
],
"id": "CVE-2020-20741",
"lastModified": "2024-11-21T05:12:15.890",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-07-23T20:15:08.017",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Mitigation",
"Patch",
"Vendor Advisory"
],
"url": "https://download.beckhoff.com/download/Document/product-security/Advisories/advisory-2019-006.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Patch",
"Vendor Advisory"
],
"url": "https://download.beckhoff.com/download/Document/product-security/Advisories/advisory-2019-006.pdf"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-Other"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
CVE-2020-20741 (GCVE-0-2020-20741)
Vulnerability from cvelistv5 – Published: 2021-07-23 19:25 – Updated: 2024-08-04 14:22- n/a
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T14:22:25.395Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://download.beckhoff.com/download/Document/product-security/Advisories/advisory-2019-006.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Incorrect Access Control in Beckhoff Automation GmbH \u0026 Co. KG CX9020 with firmware version CX9020_CB3011_WEC7_HPS_v602_TC31_B4016.6 allows remote attackers to bypass authentication via the \"CE Remote Display Tool\" as it does not close the incoming connection on the Windows CE side if the credentials are incorrect."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-07-23T19:25:46",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://download.beckhoff.com/download/Document/product-security/Advisories/advisory-2019-006.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-20741",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Incorrect Access Control in Beckhoff Automation GmbH \u0026 Co. KG CX9020 with firmware version CX9020_CB3011_WEC7_HPS_v602_TC31_B4016.6 allows remote attackers to bypass authentication via the \"CE Remote Display Tool\" as it does not close the incoming connection on the Windows CE side if the credentials are incorrect."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://download.beckhoff.com/download/Document/product-security/Advisories/advisory-2019-006.pdf",
"refsource": "MISC",
"url": "https://download.beckhoff.com/download/Document/product-security/Advisories/advisory-2019-006.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-20741",
"datePublished": "2021-07-23T19:25:46",
"dateReserved": "2020-08-13T00:00:00",
"dateUpdated": "2024-08-04T14:22:25.395Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-20741 (GCVE-0-2020-20741)
Vulnerability from nvd – Published: 2021-07-23 19:25 – Updated: 2024-08-04 14:22- n/a
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T14:22:25.395Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://download.beckhoff.com/download/Document/product-security/Advisories/advisory-2019-006.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Incorrect Access Control in Beckhoff Automation GmbH \u0026 Co. KG CX9020 with firmware version CX9020_CB3011_WEC7_HPS_v602_TC31_B4016.6 allows remote attackers to bypass authentication via the \"CE Remote Display Tool\" as it does not close the incoming connection on the Windows CE side if the credentials are incorrect."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-07-23T19:25:46",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://download.beckhoff.com/download/Document/product-security/Advisories/advisory-2019-006.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-20741",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Incorrect Access Control in Beckhoff Automation GmbH \u0026 Co. KG CX9020 with firmware version CX9020_CB3011_WEC7_HPS_v602_TC31_B4016.6 allows remote attackers to bypass authentication via the \"CE Remote Display Tool\" as it does not close the incoming connection on the Windows CE side if the credentials are incorrect."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://download.beckhoff.com/download/Document/product-security/Advisories/advisory-2019-006.pdf",
"refsource": "MISC",
"url": "https://download.beckhoff.com/download/Document/product-security/Advisories/advisory-2019-006.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-20741",
"datePublished": "2021-07-23T19:25:46",
"dateReserved": "2020-08-13T00:00:00",
"dateUpdated": "2024-08-04T14:22:25.395Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",