    CVE-2012-2515 (GCVE-0-2012-2515)

    Vulnerability from nvd – Published: 2012-07-05 01:00 – Updated: 2024-09-16 17:37
    VLAI
    Summary
    Multiple stack-based buffer overflows in the KeyHelp.KeyCtrl.1 ActiveX control in KeyHelp.ocx 1.2.312 in KeyWorks KeyHelp Module (aka the HTML Help component), as used in EMC Documentum ApplicationXtender Desktop 5.4; EMC Captiva Quickscan Pro 4.6 SP1; GE Intelligent Platforms Proficy Historian 3.1, 3.5, 4.0, and 4.5; GE Intelligent Platforms Proficy HMI/SCADA iFIX 5.0 and 5.1; GE Intelligent Platforms Proficy Pulse 1.0; GE Intelligent Platforms Proficy Batch Execution 5.6; GE Intelligent Platforms SI7 I/O Driver 7.20 through 7.42; and other products, allow remote attackers to execute arbitrary code via a long string in the second argument to the (1) JumpMappedID or (2) JumpURL method.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T19:34:25.874Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "ADV-2009-2795",
                "tags": [
                  "vdb-entry",
                  "x_refsource_VUPEN",
                  "x_transferred"
                ],
                "url": "http://www.vupen.com/english/advisories/2009/2795"
              },
              {
                "name": "ADV-2009-2793",
                "tags": [
                  "vdb-entry",
                  "x_refsource_VUPEN",
                  "x_transferred"
                ],
                "url": "http://www.vupen.com/english/advisories/2009/2793"
              },
              {
                "name": "36546",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/36546"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://support.ge-ip.com/support/resources/sites/GE_FANUC_SUPPORT/content/live/KB/14000/KB14863/en_US/GEIP12-04%20Security%20Advisory%20-%20Proficy%20HTML%20Help.pdf"
              },
              {
                "name": "36914",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_SECUNIA",
                  "x_transferred"
                ],
                "url": "http://secunia.com/advisories/36914"
              },
              {
                "name": "36905",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_SECUNIA",
                  "x_transferred"
                ],
                "url": "http://secunia.com/advisories/36905"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-131-02.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://retrogod.altervista.org/9sg_emc_keyhelp.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Multiple stack-based buffer overflows in the KeyHelp.KeyCtrl.1 ActiveX control in KeyHelp.ocx 1.2.312 in KeyWorks KeyHelp Module (aka the HTML Help component), as used in EMC Documentum ApplicationXtender Desktop 5.4; EMC Captiva Quickscan Pro 4.6 SP1; GE Intelligent Platforms Proficy Historian 3.1, 3.5, 4.0, and 4.5; GE Intelligent Platforms Proficy HMI/SCADA iFIX 5.0 and 5.1; GE Intelligent Platforms Proficy Pulse 1.0; GE Intelligent Platforms Proficy Batch Execution 5.6; GE Intelligent Platforms SI7 I/O Driver 7.20 through 7.42; and other products, allow remote attackers to execute arbitrary code via a long string in the second argument to the (1) JumpMappedID or (2) JumpURL method."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2012-07-05T01:00:00.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "name": "ADV-2009-2795",
              "tags": [
                "vdb-entry",
                "x_refsource_VUPEN"
              ],
              "url": "http://www.vupen.com/english/advisories/2009/2795"
            },
            {
              "name": "ADV-2009-2793",
              "tags": [
                "vdb-entry",
                "x_refsource_VUPEN"
              ],
              "url": "http://www.vupen.com/english/advisories/2009/2793"
            },
            {
              "name": "36546",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/36546"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://support.ge-ip.com/support/resources/sites/GE_FANUC_SUPPORT/content/live/KB/14000/KB14863/en_US/GEIP12-04%20Security%20Advisory%20-%20Proficy%20HTML%20Help.pdf"
            },
            {
              "name": "36914",
              "tags": [
                "third-party-advisory",
                "x_refsource_SECUNIA"
              ],
              "url": "http://secunia.com/advisories/36914"
            },
            {
              "name": "36905",
              "tags": [
                "third-party-advisory",
                "x_refsource_SECUNIA"
              ],
              "url": "http://secunia.com/advisories/36905"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-131-02.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://retrogod.altervista.org/9sg_emc_keyhelp.html"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2012-2515",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Multiple stack-based buffer overflows in the KeyHelp.KeyCtrl.1 ActiveX control in KeyHelp.ocx 1.2.312 in KeyWorks KeyHelp Module (aka the HTML Help component), as used in EMC Documentum ApplicationXtender Desktop 5.4; EMC Captiva Quickscan Pro 4.6 SP1; GE Intelligent Platforms Proficy Historian 3.1, 3.5, 4.0, and 4.5; GE Intelligent Platforms Proficy HMI/SCADA iFIX 5.0 and 5.1; GE Intelligent Platforms Proficy Pulse 1.0; GE Intelligent Platforms Proficy Batch Execution 5.6; GE Intelligent Platforms SI7 I/O Driver 7.20 through 7.42; and other products, allow remote attackers to execute arbitrary code via a long string in the second argument to the (1) JumpMappedID or (2) JumpURL method."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "ADV-2009-2795",
                  "refsource": "VUPEN",
                  "url": "http://www.vupen.com/english/advisories/2009/2795"
                },
                {
                  "name": "ADV-2009-2793",
                  "refsource": "VUPEN",
                  "url": "http://www.vupen.com/english/advisories/2009/2793"
                },
                {
                  "name": "36546",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/36546"
                },
                {
                  "name": "http://support.ge-ip.com/support/resources/sites/GE_FANUC_SUPPORT/content/live/KB/14000/KB14863/en_US/GEIP12-04%20Security%20Advisory%20-%20Proficy%20HTML%20Help.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://support.ge-ip.com/support/resources/sites/GE_FANUC_SUPPORT/content/live/KB/14000/KB14863/en_US/GEIP12-04%20Security%20Advisory%20-%20Proficy%20HTML%20Help.pdf"
                },
                {
                  "name": "36914",
                  "refsource": "SECUNIA",
                  "url": "http://secunia.com/advisories/36914"
                },
                {
                  "name": "36905",
                  "refsource": "SECUNIA",
                  "url": "http://secunia.com/advisories/36905"
                },
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-131-02.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-131-02.pdf"
                },
                {
                  "name": "http://retrogod.altervista.org/9sg_emc_keyhelp.html",
                  "refsource": "MISC",
                  "url": "http://retrogod.altervista.org/9sg_emc_keyhelp.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2012-2515",
        "datePublished": "2012-07-05T01:00:00.000Z",
        "dateReserved": "2012-05-07T00:00:00.000Z",
        "dateUpdated": "2024-09-16T17:37:55.554Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2012-2515 (GCVE-0-2012-2515)

    Vulnerability from cvelistv5 – Published: 2012-07-05 01:00 – Updated: 2024-09-16 17:37
    VLAI
    Summary
    Multiple stack-based buffer overflows in the KeyHelp.KeyCtrl.1 ActiveX control in KeyHelp.ocx 1.2.312 in KeyWorks KeyHelp Module (aka the HTML Help component), as used in EMC Documentum ApplicationXtender Desktop 5.4; EMC Captiva Quickscan Pro 4.6 SP1; GE Intelligent Platforms Proficy Historian 3.1, 3.5, 4.0, and 4.5; GE Intelligent Platforms Proficy HMI/SCADA iFIX 5.0 and 5.1; GE Intelligent Platforms Proficy Pulse 1.0; GE Intelligent Platforms Proficy Batch Execution 5.6; GE Intelligent Platforms SI7 I/O Driver 7.20 through 7.42; and other products, allow remote attackers to execute arbitrary code via a long string in the second argument to the (1) JumpMappedID or (2) JumpURL method.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T19:34:25.874Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "ADV-2009-2795",
                "tags": [
                  "vdb-entry",
                  "x_refsource_VUPEN",
                  "x_transferred"
                ],
                "url": "http://www.vupen.com/english/advisories/2009/2795"
              },
              {
                "name": "ADV-2009-2793",
                "tags": [
                  "vdb-entry",
                  "x_refsource_VUPEN",
                  "x_transferred"
                ],
                "url": "http://www.vupen.com/english/advisories/2009/2793"
              },
              {
                "name": "36546",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/36546"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://support.ge-ip.com/support/resources/sites/GE_FANUC_SUPPORT/content/live/KB/14000/KB14863/en_US/GEIP12-04%20Security%20Advisory%20-%20Proficy%20HTML%20Help.pdf"
              },
              {
                "name": "36914",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_SECUNIA",
                  "x_transferred"
                ],
                "url": "http://secunia.com/advisories/36914"
              },
              {
                "name": "36905",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_SECUNIA",
                  "x_transferred"
                ],
                "url": "http://secunia.com/advisories/36905"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-131-02.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://retrogod.altervista.org/9sg_emc_keyhelp.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Multiple stack-based buffer overflows in the KeyHelp.KeyCtrl.1 ActiveX control in KeyHelp.ocx 1.2.312 in KeyWorks KeyHelp Module (aka the HTML Help component), as used in EMC Documentum ApplicationXtender Desktop 5.4; EMC Captiva Quickscan Pro 4.6 SP1; GE Intelligent Platforms Proficy Historian 3.1, 3.5, 4.0, and 4.5; GE Intelligent Platforms Proficy HMI/SCADA iFIX 5.0 and 5.1; GE Intelligent Platforms Proficy Pulse 1.0; GE Intelligent Platforms Proficy Batch Execution 5.6; GE Intelligent Platforms SI7 I/O Driver 7.20 through 7.42; and other products, allow remote attackers to execute arbitrary code via a long string in the second argument to the (1) JumpMappedID or (2) JumpURL method."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2012-07-05T01:00:00.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "name": "ADV-2009-2795",
              "tags": [
                "vdb-entry",
                "x_refsource_VUPEN"
              ],
              "url": "http://www.vupen.com/english/advisories/2009/2795"
            },
            {
              "name": "ADV-2009-2793",
              "tags": [
                "vdb-entry",
                "x_refsource_VUPEN"
              ],
              "url": "http://www.vupen.com/english/advisories/2009/2793"
            },
            {
              "name": "36546",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/36546"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://support.ge-ip.com/support/resources/sites/GE_FANUC_SUPPORT/content/live/KB/14000/KB14863/en_US/GEIP12-04%20Security%20Advisory%20-%20Proficy%20HTML%20Help.pdf"
            },
            {
              "name": "36914",
              "tags": [
                "third-party-advisory",
                "x_refsource_SECUNIA"
              ],
              "url": "http://secunia.com/advisories/36914"
            },
            {
              "name": "36905",
              "tags": [
                "third-party-advisory",
                "x_refsource_SECUNIA"
              ],
              "url": "http://secunia.com/advisories/36905"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-131-02.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://retrogod.altervista.org/9sg_emc_keyhelp.html"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2012-2515",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Multiple stack-based buffer overflows in the KeyHelp.KeyCtrl.1 ActiveX control in KeyHelp.ocx 1.2.312 in KeyWorks KeyHelp Module (aka the HTML Help component), as used in EMC Documentum ApplicationXtender Desktop 5.4; EMC Captiva Quickscan Pro 4.6 SP1; GE Intelligent Platforms Proficy Historian 3.1, 3.5, 4.0, and 4.5; GE Intelligent Platforms Proficy HMI/SCADA iFIX 5.0 and 5.1; GE Intelligent Platforms Proficy Pulse 1.0; GE Intelligent Platforms Proficy Batch Execution 5.6; GE Intelligent Platforms SI7 I/O Driver 7.20 through 7.42; and other products, allow remote attackers to execute arbitrary code via a long string in the second argument to the (1) JumpMappedID or (2) JumpURL method."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "ADV-2009-2795",
                  "refsource": "VUPEN",
                  "url": "http://www.vupen.com/english/advisories/2009/2795"
                },
                {
                  "name": "ADV-2009-2793",
                  "refsource": "VUPEN",
                  "url": "http://www.vupen.com/english/advisories/2009/2793"
                },
                {
                  "name": "36546",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/36546"
                },
                {
                  "name": "http://support.ge-ip.com/support/resources/sites/GE_FANUC_SUPPORT/content/live/KB/14000/KB14863/en_US/GEIP12-04%20Security%20Advisory%20-%20Proficy%20HTML%20Help.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://support.ge-ip.com/support/resources/sites/GE_FANUC_SUPPORT/content/live/KB/14000/KB14863/en_US/GEIP12-04%20Security%20Advisory%20-%20Proficy%20HTML%20Help.pdf"
                },
                {
                  "name": "36914",
                  "refsource": "SECUNIA",
                  "url": "http://secunia.com/advisories/36914"
                },
                {
                  "name": "36905",
                  "refsource": "SECUNIA",
                  "url": "http://secunia.com/advisories/36905"
                },
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-131-02.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-131-02.pdf"
                },
                {
                  "name": "http://retrogod.altervista.org/9sg_emc_keyhelp.html",
                  "refsource": "MISC",
                  "url": "http://retrogod.altervista.org/9sg_emc_keyhelp.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2012-2515",
        "datePublished": "2012-07-05T01:00:00.000Z",
        "dateReserved": "2012-05-07T00:00:00.000Z",
        "dateUpdated": "2024-09-16T17:37:55.554Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }