VAR-201803-1000
Vulnerability from variot - Updated: 2023-12-18 13:38Ubiquiti Networks EdgeOS version 1.9.1.1 and prior suffer from an Improper Privilege Management vulnerability due to the lack of validation on the input of the Feature functionality. An attacker with access to an operator (read-only) account and ssh connection to the devices could escalate privileges to admin (root) access in the system. Ubiquiti Networks EdgeOS Contains vulnerabilities related to authorization, permissions, and access control.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Ubiquiti Networks EdgeOS is an operating system of Ubiquiti Networks that runs on Ubiquiti products. A security vulnerability exists in Ubiquiti Networks EdgeOS 1.9.1.1 and earlier versions. The vulnerability is caused by the program not validating the input to the security function. An attacker could exploit this vulnerability to elevate privileges to administrator (root) privileges
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201803-1000",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "edgeos",
"scope": "lte",
"trust": 1.0,
"vendor": "ubnt",
"version": "1.9.1.1"
},
{
"model": "edgeos",
"scope": "lte",
"trust": 0.8,
"vendor": "ubiquiti",
"version": "1.9.1.1"
},
{
"model": "edgeos",
"scope": "eq",
"trust": 0.6,
"vendor": "ubnt",
"version": "1.9.1.1"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-012986"
},
{
"db": "NVD",
"id": "CVE-2017-0932"
},
{
"db": "CNNVD",
"id": "CNNVD-201803-806"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:ubnt:edgeos:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "1.9.1.1",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2017-0932"
}
]
},
"cve": "CVE-2017-0932",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": true,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "NVD",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "Single",
"author": "NVD",
"availabilityImpact": "Complete",
"baseScore": 9.0,
"confidentialityImpact": "Complete",
"exploitabilityScore": null,
"id": "CVE-2017-0932",
"impactScore": null,
"integrityImpact": "Complete",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "VULHUB",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"id": "VHN-99751",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:S/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 8.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2017-0932",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2017-0932",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201803-806",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULHUB",
"id": "VHN-99751",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-99751"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-012986"
},
{
"db": "NVD",
"id": "CVE-2017-0932"
},
{
"db": "CNNVD",
"id": "CNNVD-201803-806"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Ubiquiti Networks EdgeOS version 1.9.1.1 and prior suffer from an Improper Privilege Management vulnerability due to the lack of validation on the input of the Feature functionality. An attacker with access to an operator (read-only) account and ssh connection to the devices could escalate privileges to admin (root) access in the system. Ubiquiti Networks EdgeOS Contains vulnerabilities related to authorization, permissions, and access control.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Ubiquiti Networks EdgeOS is an operating system of Ubiquiti Networks that runs on Ubiquiti products. A security vulnerability exists in Ubiquiti Networks EdgeOS 1.9.1.1 and earlier versions. The vulnerability is caused by the program not validating the input to the security function. An attacker could exploit this vulnerability to elevate privileges to administrator (root) privileges",
"sources": [
{
"db": "NVD",
"id": "CVE-2017-0932"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-012986"
},
{
"db": "VULHUB",
"id": "VHN-99751"
}
],
"trust": 1.71
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2017-0932",
"trust": 2.5
},
{
"db": "HACKERONE",
"id": "239719",
"trust": 1.7
},
{
"db": "JVNDB",
"id": "JVNDB-2017-012986",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201803-806",
"trust": 0.7
},
{
"db": "VULHUB",
"id": "VHN-99751",
"trust": 0.1
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-99751"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-012986"
},
{
"db": "NVD",
"id": "CVE-2017-0932"
},
{
"db": "CNNVD",
"id": "CNNVD-201803-806"
}
]
},
"id": "VAR-201803-1000",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VULHUB",
"id": "VHN-99751"
}
],
"trust": 0.01
},
"last_update_date": "2023-12-18T13:38:43.084000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "EdgeMAX EdgeRouter software security release v1.9.7+hotfix.3",
"trust": 0.8,
"url": "https://community.ubnt.com/t5/edgemax-updates-blog/edgemax-edgerouter-software-security-release-v1-9-7-hotfix-3/ba-p/2054117"
},
{
"title": "Ubiquiti Networks EdgeOS Security vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=79367"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-012986"
},
{
"db": "CNNVD",
"id": "CNNVD-201803-806"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-269",
"trust": 1.1
},
{
"problemtype": "CWE-264",
"trust": 0.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-99751"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-012986"
},
{
"db": "NVD",
"id": "CVE-2017-0932"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.7,
"url": "https://community.ubnt.com/t5/edgemax-updates-blog/edgemax-edgerouter-software-security-release-v1-9-7-hotfix-3/ba-p/2054117"
},
{
"trust": 1.7,
"url": "https://hackerone.com/reports/239719"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-0932"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2017-0932"
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-99751"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-012986"
},
{
"db": "NVD",
"id": "CVE-2017-0932"
},
{
"db": "CNNVD",
"id": "CNNVD-201803-806"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULHUB",
"id": "VHN-99751"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-012986"
},
{
"db": "NVD",
"id": "CVE-2017-0932"
},
{
"db": "CNNVD",
"id": "CNNVD-201803-806"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2018-03-22T00:00:00",
"db": "VULHUB",
"id": "VHN-99751"
},
{
"date": "2018-05-15T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-012986"
},
{
"date": "2018-03-22T14:29:00.223000",
"db": "NVD",
"id": "CVE-2017-0932"
},
{
"date": "2018-03-23T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201803-806"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-10-09T00:00:00",
"db": "VULHUB",
"id": "VHN-99751"
},
{
"date": "2018-05-15T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-012986"
},
{
"date": "2019-10-09T23:21:14.057000",
"db": "NVD",
"id": "CVE-2017-0932"
},
{
"date": "2019-10-17T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201803-806"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201803-806"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Ubiquiti Networks EdgeOS Vulnerabilities related to authorization, permissions, and access control",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-012986"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "permissions and access control issues",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201803-806"
}
],
"trust": 0.6
}
}
VAR-201803-1003
Vulnerability from variot - Updated: 2023-12-18 13:28Ubiquiti Networks EdgeOS version 1.9.1.1 and prior suffer from an Improper Privilege Management vulnerability due to the lack of protection of the file system leading to sensitive information being exposed. An attacker with access to an operator (read-only) account could escalate privileges to admin (root) access in the system. Ubiquiti Networks EdgeOS Contains vulnerabilities related to authorization, permissions, and access control.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Ubiquiti Networks EdgeOS is an operating system of Ubiquiti Networks that runs on Ubiquiti products. A security vulnerability exists in Ubiquiti Networks EdgeOS 1.9.1.1 and earlier versions. The vulnerability stems from the program's lack of protection for the file system. An attacker could exploit this vulnerability to obtain sensitive information and elevate to administrator privileges
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201803-1003",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "edgeos",
"scope": "lte",
"trust": 1.0,
"vendor": "ui",
"version": "1.9.1.1"
},
{
"model": "edgeos",
"scope": "lte",
"trust": 0.8,
"vendor": "ubiquiti",
"version": "1.9.1.1"
},
{
"model": "edgeos",
"scope": "eq",
"trust": 0.6,
"vendor": "ubnt",
"version": "1.9.1.1"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-012989"
},
{
"db": "NVD",
"id": "CVE-2017-0935"
},
{
"db": "CNNVD",
"id": "CNNVD-201803-803"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:ui:edgeos:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "1.9.1.1",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2017-0935"
}
]
},
"cve": "CVE-2017-0935",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": true,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "NVD",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "Single",
"author": "NVD",
"availabilityImpact": "Complete",
"baseScore": 9.0,
"confidentialityImpact": "Complete",
"exploitabilityScore": null,
"id": "CVE-2017-0935",
"impactScore": null,
"integrityImpact": "Complete",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.9,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "VULHUB",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"id": "VHN-99754",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:S/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 8.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2017-0935",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2017-0935",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201803-803",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULHUB",
"id": "VHN-99754",
"trust": 0.1,
"value": "HIGH"
},
{
"author": "VULMON",
"id": "CVE-2017-0935",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-99754"
},
{
"db": "VULMON",
"id": "CVE-2017-0935"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-012989"
},
{
"db": "NVD",
"id": "CVE-2017-0935"
},
{
"db": "CNNVD",
"id": "CNNVD-201803-803"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Ubiquiti Networks EdgeOS version 1.9.1.1 and prior suffer from an Improper Privilege Management vulnerability due to the lack of protection of the file system leading to sensitive information being exposed. An attacker with access to an operator (read-only) account could escalate privileges to admin (root) access in the system. Ubiquiti Networks EdgeOS Contains vulnerabilities related to authorization, permissions, and access control.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Ubiquiti Networks EdgeOS is an operating system of Ubiquiti Networks that runs on Ubiquiti products. A security vulnerability exists in Ubiquiti Networks EdgeOS 1.9.1.1 and earlier versions. The vulnerability stems from the program\u0027s lack of protection for the file system. An attacker could exploit this vulnerability to obtain sensitive information and elevate to administrator privileges",
"sources": [
{
"db": "NVD",
"id": "CVE-2017-0935"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-012989"
},
{
"db": "VULHUB",
"id": "VHN-99754"
},
{
"db": "VULMON",
"id": "CVE-2017-0935"
}
],
"trust": 1.8
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2017-0935",
"trust": 2.6
},
{
"db": "HACKERONE",
"id": "242407",
"trust": 1.8
},
{
"db": "JVNDB",
"id": "JVNDB-2017-012989",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201803-803",
"trust": 0.6
},
{
"db": "VULHUB",
"id": "VHN-99754",
"trust": 0.1
},
{
"db": "VULMON",
"id": "CVE-2017-0935",
"trust": 0.1
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-99754"
},
{
"db": "VULMON",
"id": "CVE-2017-0935"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-012989"
},
{
"db": "NVD",
"id": "CVE-2017-0935"
},
{
"db": "CNNVD",
"id": "CNNVD-201803-803"
}
]
},
"id": "VAR-201803-1003",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VULHUB",
"id": "VHN-99754"
}
],
"trust": 0.01
},
"last_update_date": "2023-12-18T13:28:59.638000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "EdgeMAX EdgeRouter software security release v1.9.7+hotfix.3",
"trust": 0.8,
"url": "https://community.ubnt.com/t5/edgemax-updates-blog/edgemax-edgerouter-software-security-release-v1-9-7-hotfix-3/ba-p/2054117"
},
{
"title": "Ubiquiti Networks EdgeOS Security vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=79364"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-012989"
},
{
"db": "CNNVD",
"id": "CNNVD-201803-803"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-269",
"trust": 1.1
},
{
"problemtype": "CWE-264",
"trust": 0.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-99754"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-012989"
},
{
"db": "NVD",
"id": "CVE-2017-0935"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://community.ubnt.com/t5/edgemax-updates-blog/edgemax-edgerouter-software-security-release-v1-9-7-hotfix-3/ba-p/2054117"
},
{
"trust": 1.8,
"url": "https://hackerone.com/reports/242407"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-0935"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2017-0935"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/269.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-99754"
},
{
"db": "VULMON",
"id": "CVE-2017-0935"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-012989"
},
{
"db": "NVD",
"id": "CVE-2017-0935"
},
{
"db": "CNNVD",
"id": "CNNVD-201803-803"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULHUB",
"id": "VHN-99754"
},
{
"db": "VULMON",
"id": "CVE-2017-0935"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-012989"
},
{
"db": "NVD",
"id": "CVE-2017-0935"
},
{
"db": "CNNVD",
"id": "CNNVD-201803-803"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2018-03-22T00:00:00",
"db": "VULHUB",
"id": "VHN-99754"
},
{
"date": "2018-03-22T00:00:00",
"db": "VULMON",
"id": "CVE-2017-0935"
},
{
"date": "2018-05-15T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-012989"
},
{
"date": "2018-03-22T14:29:00.427000",
"db": "NVD",
"id": "CVE-2017-0935"
},
{
"date": "2018-03-23T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201803-803"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-02-12T00:00:00",
"db": "VULHUB",
"id": "VHN-99754"
},
{
"date": "2020-02-12T00:00:00",
"db": "VULMON",
"id": "CVE-2017-0935"
},
{
"date": "2018-05-15T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-012989"
},
{
"date": "2020-02-12T21:34:38.093000",
"db": "NVD",
"id": "CVE-2017-0935"
},
{
"date": "2019-10-17T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201803-803"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201803-803"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Ubiquiti Networks EdgeOS Vulnerabilities related to authorization, permissions, and access control",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-012989"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "permissions and access control issues",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201803-803"
}
],
"trust": 0.6
}
}
VAR-201803-1001
Vulnerability from variot - Updated: 2023-12-18 12:36Ubiquiti Networks EdgeOS version 1.9.1 and prior suffer from a Cross-Site Request Forgery (CSRF) vulnerability. An attacker with access to an operator (read-only) account could lure an admin (root) user to access the attacker-controlled page, allowing the attacker to gain admin privileges in the system. Ubiquiti Networks EdgeOS Contains a cross-site request forgery vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Ubiquiti Networks EdgeOS is an operating system of Ubiquiti Networks that runs on Ubiquiti products
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201803-1001",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "edgeos",
"scope": "lte",
"trust": 1.0,
"vendor": "ubnt",
"version": "1.9.1"
},
{
"model": "edgeos",
"scope": "lte",
"trust": 0.8,
"vendor": "ubiquiti",
"version": "1.9.1"
},
{
"model": "edgeos",
"scope": "eq",
"trust": 0.6,
"vendor": "ubnt",
"version": "1.9.1"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-012987"
},
{
"db": "NVD",
"id": "CVE-2017-0933"
},
{
"db": "CNNVD",
"id": "CNNVD-201803-805"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:ubnt:edgeos:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "1.9.1",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2017-0933"
}
]
},
"cve": "CVE-2017-0933",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "NVD",
"availabilityImpact": "COMPLETE",
"baseScore": 8.5,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 6.8,
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": true,
"vectorString": "AV:N/AC:M/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Medium",
"accessVector": "Network",
"authentication": "Single",
"author": "NVD",
"availabilityImpact": "Complete",
"baseScore": 8.5,
"confidentialityImpact": "Complete",
"exploitabilityScore": null,
"id": "CVE-2017-0933",
"impactScore": null,
"integrityImpact": "Complete",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:M/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "VULHUB",
"availabilityImpact": "COMPLETE",
"baseScore": 8.5,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 6.8,
"id": "VHN-99752",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.1,
"vectorString": "AV:N/AC:M/AU:S/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 8.0,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.1,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 8.0,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2017-0933",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2017-0933",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201803-805",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULHUB",
"id": "VHN-99752",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-99752"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-012987"
},
{
"db": "NVD",
"id": "CVE-2017-0933"
},
{
"db": "CNNVD",
"id": "CNNVD-201803-805"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Ubiquiti Networks EdgeOS version 1.9.1 and prior suffer from a Cross-Site Request Forgery (CSRF) vulnerability. An attacker with access to an operator (read-only) account could lure an admin (root) user to access the attacker-controlled page, allowing the attacker to gain admin privileges in the system. Ubiquiti Networks EdgeOS Contains a cross-site request forgery vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Ubiquiti Networks EdgeOS is an operating system of Ubiquiti Networks that runs on Ubiquiti products",
"sources": [
{
"db": "NVD",
"id": "CVE-2017-0933"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-012987"
},
{
"db": "VULHUB",
"id": "VHN-99752"
}
],
"trust": 1.71
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2017-0933",
"trust": 2.5
},
{
"db": "HACKERONE",
"id": "240098",
"trust": 1.7
},
{
"db": "JVNDB",
"id": "JVNDB-2017-012987",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201803-805",
"trust": 0.6
},
{
"db": "VULHUB",
"id": "VHN-99752",
"trust": 0.1
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-99752"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-012987"
},
{
"db": "NVD",
"id": "CVE-2017-0933"
},
{
"db": "CNNVD",
"id": "CNNVD-201803-805"
}
]
},
"id": "VAR-201803-1001",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VULHUB",
"id": "VHN-99752"
}
],
"trust": 0.01
},
"last_update_date": "2023-12-18T12:36:55.459000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "EdgeMAX EdgeRouter software release v1.9.1.1",
"trust": 0.8,
"url": "https://community.ubnt.com/t5/edgemax-updates-blog/edgemax-edgerouter-software-release-v1-9-1-1/ba-p/1910524"
},
{
"title": "Ubiquiti Networks EdgeOS Fixes for cross-site request forgery vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=79366"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-012987"
},
{
"db": "CNNVD",
"id": "CNNVD-201803-805"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-352",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-99752"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-012987"
},
{
"db": "NVD",
"id": "CVE-2017-0933"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.7,
"url": "https://community.ubnt.com/t5/edgemax-updates-blog/edgemax-edgerouter-software-release-v1-9-1-1/ba-p/1910524"
},
{
"trust": 1.7,
"url": "https://hackerone.com/reports/240098"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-0933"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2017-0933"
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-99752"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-012987"
},
{
"db": "NVD",
"id": "CVE-2017-0933"
},
{
"db": "CNNVD",
"id": "CNNVD-201803-805"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULHUB",
"id": "VHN-99752"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-012987"
},
{
"db": "NVD",
"id": "CVE-2017-0933"
},
{
"db": "CNNVD",
"id": "CNNVD-201803-805"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2018-03-22T00:00:00",
"db": "VULHUB",
"id": "VHN-99752"
},
{
"date": "2018-05-15T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-012987"
},
{
"date": "2018-03-22T14:29:00.287000",
"db": "NVD",
"id": "CVE-2017-0933"
},
{
"date": "2018-03-23T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201803-805"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-10-09T00:00:00",
"db": "VULHUB",
"id": "VHN-99752"
},
{
"date": "2018-05-15T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-012987"
},
{
"date": "2019-10-09T23:21:14.197000",
"db": "NVD",
"id": "CVE-2017-0933"
},
{
"date": "2019-10-17T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201803-805"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201803-805"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Ubiquiti Networks EdgeOS Vulnerable to cross-site request forgery",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-012987"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "cross-site request forgery",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201803-805"
}
],
"trust": 0.6
}
}
VAR-201803-1002
Vulnerability from variot - Updated: 2023-12-18 12:29Ubiquiti Networks EdgeOS version 1.9.1 and prior suffer from an Improper Privilege Management vulnerability due to the lack of protection of the file system leading to sensitive information being exposed. An attacker with access to an operator (read-only) account could escalate privileges to admin (root) access in the system. Ubiquiti Networks EdgeOS Contains vulnerabilities related to authorization, permissions, and access control.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Ubiquiti Networks EdgeOS is an operating system of Ubiquiti Networks that runs on Ubiquiti products. A security vulnerability exists in Ubiquiti Networks EdgeOS 1.9.1 and earlier versions. The vulnerability stems from the program's lack of protection for the file system. An attacker could exploit this vulnerability to obtain sensitive information and elevate to administrator privileges
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201803-1002",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "edgeos",
"scope": "lte",
"trust": 1.0,
"vendor": "ubnt",
"version": "1.9.1"
},
{
"model": "edgeos",
"scope": "lte",
"trust": 0.8,
"vendor": "ubiquiti",
"version": "1.9.1"
},
{
"model": "edgeos",
"scope": "eq",
"trust": 0.6,
"vendor": "ubnt",
"version": "1.9.1"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-012988"
},
{
"db": "NVD",
"id": "CVE-2017-0934"
},
{
"db": "CNNVD",
"id": "CNNVD-201803-804"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:ubnt:edgeos:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "1.9.1",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2017-0934"
}
]
},
"cve": "CVE-2017-0934",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": true,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "NVD",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "Single",
"author": "NVD",
"availabilityImpact": "Complete",
"baseScore": 9.0,
"confidentialityImpact": "Complete",
"exploitabilityScore": null,
"id": "CVE-2017-0934",
"impactScore": null,
"integrityImpact": "Complete",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "VULHUB",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"id": "VHN-99753",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:S/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 8.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2017-0934",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2017-0934",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201803-804",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULHUB",
"id": "VHN-99753",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-99753"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-012988"
},
{
"db": "NVD",
"id": "CVE-2017-0934"
},
{
"db": "CNNVD",
"id": "CNNVD-201803-804"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Ubiquiti Networks EdgeOS version 1.9.1 and prior suffer from an Improper Privilege Management vulnerability due to the lack of protection of the file system leading to sensitive information being exposed. An attacker with access to an operator (read-only) account could escalate privileges to admin (root) access in the system. Ubiquiti Networks EdgeOS Contains vulnerabilities related to authorization, permissions, and access control.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Ubiquiti Networks EdgeOS is an operating system of Ubiquiti Networks that runs on Ubiquiti products. A security vulnerability exists in Ubiquiti Networks EdgeOS 1.9.1 and earlier versions. The vulnerability stems from the program\u0027s lack of protection for the file system. An attacker could exploit this vulnerability to obtain sensitive information and elevate to administrator privileges",
"sources": [
{
"db": "NVD",
"id": "CVE-2017-0934"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-012988"
},
{
"db": "VULHUB",
"id": "VHN-99753"
}
],
"trust": 1.71
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2017-0934",
"trust": 2.5
},
{
"db": "HACKERONE",
"id": "241044",
"trust": 1.7
},
{
"db": "JVNDB",
"id": "JVNDB-2017-012988",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201803-804",
"trust": 0.6
},
{
"db": "VULHUB",
"id": "VHN-99753",
"trust": 0.1
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-99753"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-012988"
},
{
"db": "NVD",
"id": "CVE-2017-0934"
},
{
"db": "CNNVD",
"id": "CNNVD-201803-804"
}
]
},
"id": "VAR-201803-1002",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VULHUB",
"id": "VHN-99753"
}
],
"trust": 0.01
},
"last_update_date": "2023-12-18T12:29:05.977000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "EdgeMAX EdgeRouter software release v1.9.1.1",
"trust": 0.8,
"url": "https://community.ubnt.com/t5/edgemax-updates-blog/edgemax-edgerouter-software-release-v1-9-1-1/ba-p/1910524"
},
{
"title": "Ubiquiti Networks EdgeOS Security vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=79365"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-012988"
},
{
"db": "CNNVD",
"id": "CNNVD-201803-804"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-269",
"trust": 1.1
},
{
"problemtype": "CWE-264",
"trust": 0.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-99753"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-012988"
},
{
"db": "NVD",
"id": "CVE-2017-0934"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.7,
"url": "https://community.ubnt.com/t5/edgemax-updates-blog/edgemax-edgerouter-software-release-v1-9-1-1/ba-p/1910524"
},
{
"trust": 1.7,
"url": "https://hackerone.com/reports/241044"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-0934"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2017-0934"
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-99753"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-012988"
},
{
"db": "NVD",
"id": "CVE-2017-0934"
},
{
"db": "CNNVD",
"id": "CNNVD-201803-804"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULHUB",
"id": "VHN-99753"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-012988"
},
{
"db": "NVD",
"id": "CVE-2017-0934"
},
{
"db": "CNNVD",
"id": "CNNVD-201803-804"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2018-03-22T00:00:00",
"db": "VULHUB",
"id": "VHN-99753"
},
{
"date": "2018-05-15T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-012988"
},
{
"date": "2018-03-22T14:29:00.347000",
"db": "NVD",
"id": "CVE-2017-0934"
},
{
"date": "2018-03-23T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201803-804"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-10-09T00:00:00",
"db": "VULHUB",
"id": "VHN-99753"
},
{
"date": "2018-05-15T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-012988"
},
{
"date": "2019-10-09T23:21:14.307000",
"db": "NVD",
"id": "CVE-2017-0934"
},
{
"date": "2019-10-17T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201803-804"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201803-804"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Ubiquiti Networks EdgeOS Vulnerabilities related to authorization, permissions, and access control",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-012988"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "permissions and access control issues",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201803-804"
}
],
"trust": 0.6
}
}
FKIE_CVE-2017-0934
Vulnerability from fkie_nvd - Published: 2018-03-22 14:29 - Updated: 2024-11-21 03:03{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ubnt:edgeos:*:*:*:*:*:*:*:*",
"matchCriteriaId": "242ADBE9-D81C-46F9-A4EB-905A0FED5354",
"versionEndIncluding": "1.9.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Ubiquiti Networks EdgeOS version 1.9.1 and prior suffer from an Improper Privilege Management vulnerability due to the lack of protection of the file system leading to sensitive information being exposed. An attacker with access to an operator (read-only) account could escalate privileges to admin (root) access in the system."
},
{
"lang": "es",
"value": "Ubiquiti Networks EdgeOS, en versiones 1.9.1 y anteriores, sufre de una vulnerabilidad de gesti\u00f3n incorrecta de privilegios debido a la falta de protecci\u00f3n del sistema de archivos. Esto provoca que se exponga informaci\u00f3n sensible. Un atacante con acceso a una cuenta operator (solo lectura) podr\u00eda escalar sus privilegios a acceso admin (root) en el sistema."
}
],
"id": "CVE-2017-0934",
"lastModified": "2024-11-21T03:03:55.690",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": true,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2018-03-22T14:29:00.347",
"references": [
{
"source": "support@hackerone.com",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://community.ubnt.com/t5/EdgeMAX-Updates-Blog/EdgeMAX-EdgeRouter-software-release-v1-9-1-1/ba-p/1910524"
},
{
"source": "support@hackerone.com",
"tags": [
"Third Party Advisory"
],
"url": "https://hackerone.com/reports/241044"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://community.ubnt.com/t5/EdgeMAX-Updates-Blog/EdgeMAX-EdgeRouter-software-release-v1-9-1-1/ba-p/1910524"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://hackerone.com/reports/241044"
}
],
"sourceIdentifier": "support@hackerone.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-269"
}
],
"source": "support@hackerone.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-269"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2017-0932
Vulnerability from fkie_nvd - Published: 2018-03-22 14:29 - Updated: 2024-11-21 03:03{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ubnt:edgeos:*:*:*:*:*:*:*:*",
"matchCriteriaId": "916CDC26-434C-45EE-AB34-1AE7BE8C45AE",
"versionEndIncluding": "1.9.1.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Ubiquiti Networks EdgeOS version 1.9.1.1 and prior suffer from an Improper Privilege Management vulnerability due to the lack of validation on the input of the Feature functionality. An attacker with access to an operator (read-only) account and ssh connection to the devices could escalate privileges to admin (root) access in the system."
},
{
"lang": "es",
"value": "Ubiquiti Networks EdgeOS, en versiones 1.9.1.1 y anteriores, sufre de una vulnerabilidad de gesti\u00f3n incorrecta de privilegios debido a la falta de validaci\u00f3n de las entradas de la funcionalidad Feature. Un atacante con acceso a una cuenta operator (solo lectura) y conexi\u00f3n SSH a los dispositivos podr\u00eda escalar sus privilegios a acceso admin (root) en el sistema."
}
],
"id": "CVE-2017-0932",
"lastModified": "2024-11-21T03:03:55.460",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": true,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2018-03-22T14:29:00.223",
"references": [
{
"source": "support@hackerone.com",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://community.ubnt.com/t5/EdgeMAX-Updates-Blog/EdgeMAX-EdgeRouter-software-security-release-v1-9-7-hotfix-3/ba-p/2054117"
},
{
"source": "support@hackerone.com",
"tags": [
"Third Party Advisory"
],
"url": "https://hackerone.com/reports/239719"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://community.ubnt.com/t5/EdgeMAX-Updates-Blog/EdgeMAX-EdgeRouter-software-security-release-v1-9-7-hotfix-3/ba-p/2054117"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://hackerone.com/reports/239719"
}
],
"sourceIdentifier": "support@hackerone.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-269"
}
],
"source": "support@hackerone.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-269"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2017-0933
Vulnerability from fkie_nvd - Published: 2018-03-22 14:29 - Updated: 2024-11-21 03:03{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ubnt:edgeos:*:*:*:*:*:*:*:*",
"matchCriteriaId": "242ADBE9-D81C-46F9-A4EB-905A0FED5354",
"versionEndIncluding": "1.9.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Ubiquiti Networks EdgeOS version 1.9.1 and prior suffer from a Cross-Site Request Forgery (CSRF) vulnerability. An attacker with access to an operator (read-only) account could lure an admin (root) user to access the attacker-controlled page, allowing the attacker to gain admin privileges in the system."
},
{
"lang": "es",
"value": "Ubiquiti Networks EdgeOS, en versiones 1.9.1 y anteriores, sufre de una vulnerabilidad Cross-Site Request Forgery (CSRF). Un atacante con acceso a una cuenta operator (solo lectura) podr\u00eda enga\u00f1ar a un usuario admin (root) para que acceda a la p\u00e1gina controlada por el atacante, lo que le permitir\u00eda obtener privilegios en el sistema."
}
],
"id": "CVE-2017-0933",
"lastModified": "2024-11-21T03:03:55.573",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "COMPLETE",
"baseScore": 8.5,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:M/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 6.8,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.0,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 2.1,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2018-03-22T14:29:00.287",
"references": [
{
"source": "support@hackerone.com",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://community.ubnt.com/t5/EdgeMAX-Updates-Blog/EdgeMAX-EdgeRouter-software-release-v1-9-1-1/ba-p/1910524"
},
{
"source": "support@hackerone.com",
"tags": [
"Third Party Advisory"
],
"url": "https://hackerone.com/reports/240098"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://community.ubnt.com/t5/EdgeMAX-Updates-Blog/EdgeMAX-EdgeRouter-software-release-v1-9-1-1/ba-p/1910524"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://hackerone.com/reports/240098"
}
],
"sourceIdentifier": "support@hackerone.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-352"
}
],
"source": "support@hackerone.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-352"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
CVE-2017-0932 (GCVE-0-2017-0932)
Vulnerability from cvelistv5 – Published: 2018-03-22 14:00 – Updated: 2024-09-17 02:27- CWE-269 - Improper Privilege Management (CWE-269)
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Ubiquiti Networks | EdgeRouter X |
Affected:
EdgeOS v1.9.1.1 and prior
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T13:25:17.095Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://hackerone.com/reports/239719"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://community.ubnt.com/t5/EdgeMAX-Updates-Blog/EdgeMAX-EdgeRouter-software-security-release-v1-9-7-hotfix-3/ba-p/2054117"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "EdgeRouter X",
"vendor": "Ubiquiti Networks",
"versions": [
{
"status": "affected",
"version": "EdgeOS v1.9.1.1 and prior"
}
]
}
],
"datePublic": "2017-09-06T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Ubiquiti Networks EdgeOS version 1.9.1.1 and prior suffer from an Improper Privilege Management vulnerability due to the lack of validation on the input of the Feature functionality. An attacker with access to an operator (read-only) account and ssh connection to the devices could escalate privileges to admin (root) access in the system."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-269",
"description": "Improper Privilege Management (CWE-269)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-03-22T13:57:01",
"orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"shortName": "hackerone"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://hackerone.com/reports/239719"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://community.ubnt.com/t5/EdgeMAX-Updates-Blog/EdgeMAX-EdgeRouter-software-security-release-v1-9-7-hotfix-3/ba-p/2054117"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "support@hackerone.com",
"DATE_PUBLIC": "2017-09-06T00:00:00",
"ID": "CVE-2017-0932",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "EdgeRouter X",
"version": {
"version_data": [
{
"version_value": "EdgeOS v1.9.1.1 and prior"
}
]
}
}
]
},
"vendor_name": "Ubiquiti Networks"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Ubiquiti Networks EdgeOS version 1.9.1.1 and prior suffer from an Improper Privilege Management vulnerability due to the lack of validation on the input of the Feature functionality. An attacker with access to an operator (read-only) account and ssh connection to the devices could escalate privileges to admin (root) access in the system."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Improper Privilege Management (CWE-269)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://hackerone.com/reports/239719",
"refsource": "MISC",
"url": "https://hackerone.com/reports/239719"
},
{
"name": "https://community.ubnt.com/t5/EdgeMAX-Updates-Blog/EdgeMAX-EdgeRouter-software-security-release-v1-9-7-hotfix-3/ba-p/2054117",
"refsource": "CONFIRM",
"url": "https://community.ubnt.com/t5/EdgeMAX-Updates-Blog/EdgeMAX-EdgeRouter-software-security-release-v1-9-7-hotfix-3/ba-p/2054117"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"assignerShortName": "hackerone",
"cveId": "CVE-2017-0932",
"datePublished": "2018-03-22T14:00:00Z",
"dateReserved": "2016-11-30T00:00:00",
"dateUpdated": "2024-09-17T02:27:44.980Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-0933 (GCVE-0-2017-0933)
Vulnerability from cvelistv5 – Published: 2018-03-22 14:00 – Updated: 2024-09-16 19:41- CWE-352 - Cross-Site Request Forgery (CWE-352)
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Ubiquiti Networks | EdgeRouter X |
Affected:
EdgeOS v1.9.1 and prior
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T13:25:16.864Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://community.ubnt.com/t5/EdgeMAX-Updates-Blog/EdgeMAX-EdgeRouter-software-release-v1-9-1-1/ba-p/1910524"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://hackerone.com/reports/240098"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "EdgeRouter X",
"vendor": "Ubiquiti Networks",
"versions": [
{
"status": "affected",
"version": "EdgeOS v1.9.1 and prior"
}
]
}
],
"datePublic": "2017-05-01T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Ubiquiti Networks EdgeOS version 1.9.1 and prior suffer from a Cross-Site Request Forgery (CSRF) vulnerability. An attacker with access to an operator (read-only) account could lure an admin (root) user to access the attacker-controlled page, allowing the attacker to gain admin privileges in the system."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-352",
"description": "Cross-Site Request Forgery (CWE-352)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-03-22T13:57:01",
"orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"shortName": "hackerone"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://community.ubnt.com/t5/EdgeMAX-Updates-Blog/EdgeMAX-EdgeRouter-software-release-v1-9-1-1/ba-p/1910524"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://hackerone.com/reports/240098"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "support@hackerone.com",
"DATE_PUBLIC": "2017-05-01T00:00:00",
"ID": "CVE-2017-0933",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "EdgeRouter X",
"version": {
"version_data": [
{
"version_value": "EdgeOS v1.9.1 and prior"
}
]
}
}
]
},
"vendor_name": "Ubiquiti Networks"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Ubiquiti Networks EdgeOS version 1.9.1 and prior suffer from a Cross-Site Request Forgery (CSRF) vulnerability. An attacker with access to an operator (read-only) account could lure an admin (root) user to access the attacker-controlled page, allowing the attacker to gain admin privileges in the system."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Cross-Site Request Forgery (CWE-352)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://community.ubnt.com/t5/EdgeMAX-Updates-Blog/EdgeMAX-EdgeRouter-software-release-v1-9-1-1/ba-p/1910524",
"refsource": "CONFIRM",
"url": "https://community.ubnt.com/t5/EdgeMAX-Updates-Blog/EdgeMAX-EdgeRouter-software-release-v1-9-1-1/ba-p/1910524"
},
{
"name": "https://hackerone.com/reports/240098",
"refsource": "MISC",
"url": "https://hackerone.com/reports/240098"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"assignerShortName": "hackerone",
"cveId": "CVE-2017-0933",
"datePublished": "2018-03-22T14:00:00Z",
"dateReserved": "2016-11-30T00:00:00",
"dateUpdated": "2024-09-16T19:41:56.531Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-0934 (GCVE-0-2017-0934)
Vulnerability from cvelistv5 – Published: 2018-03-22 14:00 – Updated: 2024-09-17 04:23- CWE-269 - Improper Privilege Management (CWE-269)
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Ubiquiti Networks | EdgeRouter X |
Affected:
EdgeOS v1.9.1 and prior
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T13:25:17.084Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://hackerone.com/reports/241044"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://community.ubnt.com/t5/EdgeMAX-Updates-Blog/EdgeMAX-EdgeRouter-software-release-v1-9-1-1/ba-p/1910524"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "EdgeRouter X",
"vendor": "Ubiquiti Networks",
"versions": [
{
"status": "affected",
"version": "EdgeOS v1.9.1 and prior"
}
]
}
],
"datePublic": "2017-05-01T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Ubiquiti Networks EdgeOS version 1.9.1 and prior suffer from an Improper Privilege Management vulnerability due to the lack of protection of the file system leading to sensitive information being exposed. An attacker with access to an operator (read-only) account could escalate privileges to admin (root) access in the system."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-269",
"description": "Improper Privilege Management (CWE-269)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-03-22T13:57:01",
"orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"shortName": "hackerone"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://hackerone.com/reports/241044"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://community.ubnt.com/t5/EdgeMAX-Updates-Blog/EdgeMAX-EdgeRouter-software-release-v1-9-1-1/ba-p/1910524"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "support@hackerone.com",
"DATE_PUBLIC": "2017-05-01T00:00:00",
"ID": "CVE-2017-0934",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "EdgeRouter X",
"version": {
"version_data": [
{
"version_value": "EdgeOS v1.9.1 and prior"
}
]
}
}
]
},
"vendor_name": "Ubiquiti Networks"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Ubiquiti Networks EdgeOS version 1.9.1 and prior suffer from an Improper Privilege Management vulnerability due to the lack of protection of the file system leading to sensitive information being exposed. An attacker with access to an operator (read-only) account could escalate privileges to admin (root) access in the system."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Improper Privilege Management (CWE-269)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://hackerone.com/reports/241044",
"refsource": "MISC",
"url": "https://hackerone.com/reports/241044"
},
{
"name": "https://community.ubnt.com/t5/EdgeMAX-Updates-Blog/EdgeMAX-EdgeRouter-software-release-v1-9-1-1/ba-p/1910524",
"refsource": "CONFIRM",
"url": "https://community.ubnt.com/t5/EdgeMAX-Updates-Blog/EdgeMAX-EdgeRouter-software-release-v1-9-1-1/ba-p/1910524"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"assignerShortName": "hackerone",
"cveId": "CVE-2017-0934",
"datePublished": "2018-03-22T14:00:00Z",
"dateReserved": "2016-11-30T00:00:00",
"dateUpdated": "2024-09-17T04:23:56.390Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-0932 (GCVE-0-2017-0932)
Vulnerability from nvd – Published: 2018-03-22 14:00 – Updated: 2024-09-17 02:27- CWE-269 - Improper Privilege Management (CWE-269)
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Ubiquiti Networks | EdgeRouter X |
Affected:
EdgeOS v1.9.1.1 and prior
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T13:25:17.095Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://hackerone.com/reports/239719"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://community.ubnt.com/t5/EdgeMAX-Updates-Blog/EdgeMAX-EdgeRouter-software-security-release-v1-9-7-hotfix-3/ba-p/2054117"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "EdgeRouter X",
"vendor": "Ubiquiti Networks",
"versions": [
{
"status": "affected",
"version": "EdgeOS v1.9.1.1 and prior"
}
]
}
],
"datePublic": "2017-09-06T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Ubiquiti Networks EdgeOS version 1.9.1.1 and prior suffer from an Improper Privilege Management vulnerability due to the lack of validation on the input of the Feature functionality. An attacker with access to an operator (read-only) account and ssh connection to the devices could escalate privileges to admin (root) access in the system."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-269",
"description": "Improper Privilege Management (CWE-269)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-03-22T13:57:01",
"orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"shortName": "hackerone"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://hackerone.com/reports/239719"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://community.ubnt.com/t5/EdgeMAX-Updates-Blog/EdgeMAX-EdgeRouter-software-security-release-v1-9-7-hotfix-3/ba-p/2054117"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "support@hackerone.com",
"DATE_PUBLIC": "2017-09-06T00:00:00",
"ID": "CVE-2017-0932",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "EdgeRouter X",
"version": {
"version_data": [
{
"version_value": "EdgeOS v1.9.1.1 and prior"
}
]
}
}
]
},
"vendor_name": "Ubiquiti Networks"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Ubiquiti Networks EdgeOS version 1.9.1.1 and prior suffer from an Improper Privilege Management vulnerability due to the lack of validation on the input of the Feature functionality. An attacker with access to an operator (read-only) account and ssh connection to the devices could escalate privileges to admin (root) access in the system."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Improper Privilege Management (CWE-269)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://hackerone.com/reports/239719",
"refsource": "MISC",
"url": "https://hackerone.com/reports/239719"
},
{
"name": "https://community.ubnt.com/t5/EdgeMAX-Updates-Blog/EdgeMAX-EdgeRouter-software-security-release-v1-9-7-hotfix-3/ba-p/2054117",
"refsource": "CONFIRM",
"url": "https://community.ubnt.com/t5/EdgeMAX-Updates-Blog/EdgeMAX-EdgeRouter-software-security-release-v1-9-7-hotfix-3/ba-p/2054117"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"assignerShortName": "hackerone",
"cveId": "CVE-2017-0932",
"datePublished": "2018-03-22T14:00:00Z",
"dateReserved": "2016-11-30T00:00:00",
"dateUpdated": "2024-09-17T02:27:44.980Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-0933 (GCVE-0-2017-0933)
Vulnerability from nvd – Published: 2018-03-22 14:00 – Updated: 2024-09-16 19:41- CWE-352 - Cross-Site Request Forgery (CWE-352)
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Ubiquiti Networks | EdgeRouter X |
Affected:
EdgeOS v1.9.1 and prior
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T13:25:16.864Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://community.ubnt.com/t5/EdgeMAX-Updates-Blog/EdgeMAX-EdgeRouter-software-release-v1-9-1-1/ba-p/1910524"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://hackerone.com/reports/240098"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "EdgeRouter X",
"vendor": "Ubiquiti Networks",
"versions": [
{
"status": "affected",
"version": "EdgeOS v1.9.1 and prior"
}
]
}
],
"datePublic": "2017-05-01T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Ubiquiti Networks EdgeOS version 1.9.1 and prior suffer from a Cross-Site Request Forgery (CSRF) vulnerability. An attacker with access to an operator (read-only) account could lure an admin (root) user to access the attacker-controlled page, allowing the attacker to gain admin privileges in the system."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-352",
"description": "Cross-Site Request Forgery (CWE-352)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-03-22T13:57:01",
"orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"shortName": "hackerone"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://community.ubnt.com/t5/EdgeMAX-Updates-Blog/EdgeMAX-EdgeRouter-software-release-v1-9-1-1/ba-p/1910524"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://hackerone.com/reports/240098"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "support@hackerone.com",
"DATE_PUBLIC": "2017-05-01T00:00:00",
"ID": "CVE-2017-0933",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "EdgeRouter X",
"version": {
"version_data": [
{
"version_value": "EdgeOS v1.9.1 and prior"
}
]
}
}
]
},
"vendor_name": "Ubiquiti Networks"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Ubiquiti Networks EdgeOS version 1.9.1 and prior suffer from a Cross-Site Request Forgery (CSRF) vulnerability. An attacker with access to an operator (read-only) account could lure an admin (root) user to access the attacker-controlled page, allowing the attacker to gain admin privileges in the system."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Cross-Site Request Forgery (CWE-352)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://community.ubnt.com/t5/EdgeMAX-Updates-Blog/EdgeMAX-EdgeRouter-software-release-v1-9-1-1/ba-p/1910524",
"refsource": "CONFIRM",
"url": "https://community.ubnt.com/t5/EdgeMAX-Updates-Blog/EdgeMAX-EdgeRouter-software-release-v1-9-1-1/ba-p/1910524"
},
{
"name": "https://hackerone.com/reports/240098",
"refsource": "MISC",
"url": "https://hackerone.com/reports/240098"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"assignerShortName": "hackerone",
"cveId": "CVE-2017-0933",
"datePublished": "2018-03-22T14:00:00Z",
"dateReserved": "2016-11-30T00:00:00",
"dateUpdated": "2024-09-16T19:41:56.531Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-0934 (GCVE-0-2017-0934)
Vulnerability from nvd – Published: 2018-03-22 14:00 – Updated: 2024-09-17 04:23- CWE-269 - Improper Privilege Management (CWE-269)
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Ubiquiti Networks | EdgeRouter X |
Affected:
EdgeOS v1.9.1 and prior
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T13:25:17.084Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://hackerone.com/reports/241044"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://community.ubnt.com/t5/EdgeMAX-Updates-Blog/EdgeMAX-EdgeRouter-software-release-v1-9-1-1/ba-p/1910524"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "EdgeRouter X",
"vendor": "Ubiquiti Networks",
"versions": [
{
"status": "affected",
"version": "EdgeOS v1.9.1 and prior"
}
]
}
],
"datePublic": "2017-05-01T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Ubiquiti Networks EdgeOS version 1.9.1 and prior suffer from an Improper Privilege Management vulnerability due to the lack of protection of the file system leading to sensitive information being exposed. An attacker with access to an operator (read-only) account could escalate privileges to admin (root) access in the system."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-269",
"description": "Improper Privilege Management (CWE-269)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-03-22T13:57:01",
"orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"shortName": "hackerone"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://hackerone.com/reports/241044"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://community.ubnt.com/t5/EdgeMAX-Updates-Blog/EdgeMAX-EdgeRouter-software-release-v1-9-1-1/ba-p/1910524"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "support@hackerone.com",
"DATE_PUBLIC": "2017-05-01T00:00:00",
"ID": "CVE-2017-0934",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "EdgeRouter X",
"version": {
"version_data": [
{
"version_value": "EdgeOS v1.9.1 and prior"
}
]
}
}
]
},
"vendor_name": "Ubiquiti Networks"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Ubiquiti Networks EdgeOS version 1.9.1 and prior suffer from an Improper Privilege Management vulnerability due to the lack of protection of the file system leading to sensitive information being exposed. An attacker with access to an operator (read-only) account could escalate privileges to admin (root) access in the system."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Improper Privilege Management (CWE-269)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://hackerone.com/reports/241044",
"refsource": "MISC",
"url": "https://hackerone.com/reports/241044"
},
{
"name": "https://community.ubnt.com/t5/EdgeMAX-Updates-Blog/EdgeMAX-EdgeRouter-software-release-v1-9-1-1/ba-p/1910524",
"refsource": "CONFIRM",
"url": "https://community.ubnt.com/t5/EdgeMAX-Updates-Blog/EdgeMAX-EdgeRouter-software-release-v1-9-1-1/ba-p/1910524"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"assignerShortName": "hackerone",
"cveId": "CVE-2017-0934",
"datePublished": "2018-03-22T14:00:00Z",
"dateReserved": "2016-11-30T00:00:00",
"dateUpdated": "2024-09-17T04:23:56.390Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",