7 vulnerabilities found for edgeos by ui

VAR-201803-1003

Vulnerability from variot - Updated: 2023-12-18 13:28

Ubiquiti Networks EdgeOS version 1.9.1.1 and prior suffer from an Improper Privilege Management vulnerability due to the lack of protection of the file system leading to sensitive information being exposed. An attacker with access to an operator (read-only) account could escalate privileges to admin (root) access in the system. Ubiquiti Networks EdgeOS Contains vulnerabilities related to authorization, permissions, and access control.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Ubiquiti Networks EdgeOS is an operating system of Ubiquiti Networks that runs on Ubiquiti products. A security vulnerability exists in Ubiquiti Networks EdgeOS 1.9.1.1 and earlier versions. The vulnerability stems from the program's lack of protection for the file system. An attacker could exploit this vulnerability to obtain sensitive information and elevate to administrator privileges

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201803-1003",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "edgeos",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "ui",
        "version": "1.9.1.1"
      },
      {
        "model": "edgeos",
        "scope": "lte",
        "trust": 0.8,
        "vendor": "ubiquiti",
        "version": "1.9.1.1"
      },
      {
        "model": "edgeos",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "ubnt",
        "version": "1.9.1.1"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-012989"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-0935"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201803-803"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:o:ui:edgeos:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndIncluding": "1.9.1.1",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2017-0935"
      }
    ]
  },
  "cve": "CVE-2017-0935",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": true,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "NVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.0,
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "HIGH",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "Single",
            "author": "NVD",
            "availabilityImpact": "Complete",
            "baseScore": 9.0,
            "confidentialityImpact": "Complete",
            "exploitabilityScore": null,
            "id": "CVE-2017-0935",
            "impactScore": null,
            "integrityImpact": "Complete",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.9,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.0,
            "id": "VHN-99754",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 8.8,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2017-0935",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "Low",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2017-0935",
            "trust": 1.8,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201803-803",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-99754",
            "trust": 0.1,
            "value": "HIGH"
          },
          {
            "author": "VULMON",
            "id": "CVE-2017-0935",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-99754"
      },
      {
        "db": "VULMON",
        "id": "CVE-2017-0935"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-012989"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-0935"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201803-803"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Ubiquiti Networks EdgeOS version 1.9.1.1 and prior suffer from an Improper Privilege Management vulnerability due to the lack of protection of the file system leading to sensitive information being exposed. An attacker with access to an operator (read-only) account could escalate privileges to admin (root) access in the system. Ubiquiti Networks EdgeOS Contains vulnerabilities related to authorization, permissions, and access control.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Ubiquiti Networks EdgeOS is an operating system of Ubiquiti Networks that runs on Ubiquiti products. A security vulnerability exists in Ubiquiti Networks EdgeOS 1.9.1.1 and earlier versions. The vulnerability stems from the program\u0027s lack of protection for the file system. An attacker could exploit this vulnerability to obtain sensitive information and elevate to administrator privileges",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2017-0935"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-012989"
      },
      {
        "db": "VULHUB",
        "id": "VHN-99754"
      },
      {
        "db": "VULMON",
        "id": "CVE-2017-0935"
      }
    ],
    "trust": 1.8
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2017-0935",
        "trust": 2.6
      },
      {
        "db": "HACKERONE",
        "id": "242407",
        "trust": 1.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-012989",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201803-803",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-99754",
        "trust": 0.1
      },
      {
        "db": "VULMON",
        "id": "CVE-2017-0935",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-99754"
      },
      {
        "db": "VULMON",
        "id": "CVE-2017-0935"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-012989"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-0935"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201803-803"
      }
    ]
  },
  "id": "VAR-201803-1003",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-99754"
      }
    ],
    "trust": 0.01
  },
  "last_update_date": "2023-12-18T13:28:59.638000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "EdgeMAX EdgeRouter software security release v1.9.7+hotfix.3",
        "trust": 0.8,
        "url": "https://community.ubnt.com/t5/edgemax-updates-blog/edgemax-edgerouter-software-security-release-v1-9-7-hotfix-3/ba-p/2054117"
      },
      {
        "title": "Ubiquiti Networks EdgeOS Security vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=79364"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-012989"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201803-803"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-269",
        "trust": 1.1
      },
      {
        "problemtype": "CWE-264",
        "trust": 0.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-99754"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-012989"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-0935"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://community.ubnt.com/t5/edgemax-updates-blog/edgemax-edgerouter-software-security-release-v1-9-7-hotfix-3/ba-p/2054117"
      },
      {
        "trust": 1.8,
        "url": "https://hackerone.com/reports/242407"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-0935"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2017-0935"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/269.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-99754"
      },
      {
        "db": "VULMON",
        "id": "CVE-2017-0935"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-012989"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-0935"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201803-803"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULHUB",
        "id": "VHN-99754"
      },
      {
        "db": "VULMON",
        "id": "CVE-2017-0935"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-012989"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-0935"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201803-803"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-03-22T00:00:00",
        "db": "VULHUB",
        "id": "VHN-99754"
      },
      {
        "date": "2018-03-22T00:00:00",
        "db": "VULMON",
        "id": "CVE-2017-0935"
      },
      {
        "date": "2018-05-15T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2017-012989"
      },
      {
        "date": "2018-03-22T14:29:00.427000",
        "db": "NVD",
        "id": "CVE-2017-0935"
      },
      {
        "date": "2018-03-23T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201803-803"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-02-12T00:00:00",
        "db": "VULHUB",
        "id": "VHN-99754"
      },
      {
        "date": "2020-02-12T00:00:00",
        "db": "VULMON",
        "id": "CVE-2017-0935"
      },
      {
        "date": "2018-05-15T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2017-012989"
      },
      {
        "date": "2020-02-12T21:34:38.093000",
        "db": "NVD",
        "id": "CVE-2017-0935"
      },
      {
        "date": "2019-10-17T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201803-803"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201803-803"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Ubiquiti Networks EdgeOS Vulnerabilities related to authorization, permissions, and access control",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-012989"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "permissions and access control issues",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201803-803"
      }
    ],
    "trust": 0.6
  }
}

FKIE_CVE-2018-5265

Vulnerability from fkie_nvd - Published: 2019-06-07 15:29 - Updated: 2024-11-21 04:08
Summary
Ubiquiti EdgeOS 1.9.1 on EdgeRouter Lite devices allows remote attackers to execute arbitrary code with admin credentials, because /opt/vyatta/share/vyatta-cfg/templates/system/static-host-mapping/host-name/node.def does not sanitize the 'alias' or 'ips' parameter for shell metacharacters.
Impacted products
Vendor Product Version
ui edgeos 1.9.1
ui erlite-3 -

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:ui:edgeos:1.9.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "380A9F0D-CDE6-46BC-A22C-B7619A6DC6E1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:ui:erlite-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0071AC31-76DE-4787-9ED3-A93119B7D4A9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Ubiquiti EdgeOS 1.9.1 on EdgeRouter Lite devices allows remote attackers to execute arbitrary code with admin credentials, because /opt/vyatta/share/vyatta-cfg/templates/system/static-host-mapping/host-name/node.def does not sanitize the \u0027alias\u0027 or \u0027ips\u0027 parameter for shell metacharacters."
    },
    {
      "lang": "es",
      "value": "Ubiquiti EdgeOS versi\u00f3n 1.9.1 en dispositivos EdgeRouter Lite, permite a atacantes remotos ejecutar c\u00f3digo arbitrario con credenciales de administrador, porque /opt/vyatta/share/vyatta-cfg/templates/System/static-host-mapping/host-name/node.def no sanea el par\u00e1metro \u0027alias\u0027 o \u0027ips\u0027 para metacaracteres shell."
    }
  ],
  "id": "CVE-2018-5265",
  "lastModified": "2024-11-21T04:08:27.343",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.5,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.0,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.2,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 1.2,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2019-06-07T15:29:00.683",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://www.red4sec.com/cve/edgerouter_lite.txt"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://www.red4sec.com/cve/edgerouter_lite.txt"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-78"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2017-0935

Vulnerability from fkie_nvd - Published: 2018-03-22 14:29 - Updated: 2024-11-21 03:03
Summary
Ubiquiti Networks EdgeOS version 1.9.1.1 and prior suffer from an Improper Privilege Management vulnerability due to the lack of protection of the file system leading to sensitive information being exposed. An attacker with access to an operator (read-only) account could escalate privileges to admin (root) access in the system.
Impacted products
Vendor Product Version
ui edgeos *

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:ui:edgeos:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1D5CED05-149F-4CA5-A18D-B508E6EF1EBD",
              "versionEndIncluding": "1.9.1.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Ubiquiti Networks EdgeOS version 1.9.1.1 and prior suffer from an Improper Privilege Management vulnerability due to the lack of protection of the file system leading to sensitive information being exposed. An attacker with access to an operator (read-only) account could escalate privileges to admin (root) access in the system."
    },
    {
      "lang": "es",
      "value": "Ubiquiti Networks EdgeOS, en versiones 1.9.1.1 y anteriores, sufre de una vulnerabilidad de gesti\u00f3n incorrecta de privilegios debido a la falta de protecci\u00f3n del sistema de archivos. Esto provoca que se exponga informaci\u00f3n sensible. Un atacante con acceso a una cuenta operator (solo lectura) podr\u00eda escalar sus privilegios a acceso admin (root) en el sistema."
    }
  ],
  "id": "CVE-2017-0935",
  "lastModified": "2024-11-21T03:03:55.797",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": true,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 9.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 8.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2018-03-22T14:29:00.427",
  "references": [
    {
      "source": "support@hackerone.com",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://community.ubnt.com/t5/EdgeMAX-Updates-Blog/EdgeMAX-EdgeRouter-software-security-release-v1-9-7-hotfix-3/ba-p/2054117"
    },
    {
      "source": "support@hackerone.com",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://hackerone.com/reports/242407"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://community.ubnt.com/t5/EdgeMAX-Updates-Blog/EdgeMAX-EdgeRouter-software-security-release-v1-9-7-hotfix-3/ba-p/2054117"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://hackerone.com/reports/242407"
    }
  ],
  "sourceIdentifier": "support@hackerone.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-269"
        }
      ],
      "source": "support@hackerone.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-269"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

CVE-2018-5265 (GCVE-0-2018-5265)

Vulnerability from cvelistv5 – Published: 2019-06-07 14:59 – Updated: 2024-08-05 05:33
VLAI?
Summary
Ubiquiti EdgeOS 1.9.1 on EdgeRouter Lite devices allows remote attackers to execute arbitrary code with admin credentials, because /opt/vyatta/share/vyatta-cfg/templates/system/static-host-mapping/host-name/node.def does not sanitize the 'alias' or 'ips' parameter for shell metacharacters.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T05:33:44.365Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.red4sec.com/cve/edgerouter_lite.txt"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Ubiquiti EdgeOS 1.9.1 on EdgeRouter Lite devices allows remote attackers to execute arbitrary code with admin credentials, because /opt/vyatta/share/vyatta-cfg/templates/system/static-host-mapping/host-name/node.def does not sanitize the \u0027alias\u0027 or \u0027ips\u0027 parameter for shell metacharacters."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-06-07T14:59:43",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.red4sec.com/cve/edgerouter_lite.txt"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2018-5265",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Ubiquiti EdgeOS 1.9.1 on EdgeRouter Lite devices allows remote attackers to execute arbitrary code with admin credentials, because /opt/vyatta/share/vyatta-cfg/templates/system/static-host-mapping/host-name/node.def does not sanitize the \u0027alias\u0027 or \u0027ips\u0027 parameter for shell metacharacters."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.red4sec.com/cve/edgerouter_lite.txt",
              "refsource": "MISC",
              "url": "https://www.red4sec.com/cve/edgerouter_lite.txt"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2018-5265",
    "datePublished": "2019-06-07T14:59:43",
    "dateReserved": "2018-01-07T00:00:00",
    "dateUpdated": "2024-08-05T05:33:44.365Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-0935 (GCVE-0-2017-0935)

Vulnerability from cvelistv5 – Published: 2018-03-22 14:00 – Updated: 2024-09-17 01:11
VLAI?
Summary
Ubiquiti Networks EdgeOS version 1.9.1.1 and prior suffer from an Improper Privilege Management vulnerability due to the lack of protection of the file system leading to sensitive information being exposed. An attacker with access to an operator (read-only) account could escalate privileges to admin (root) access in the system.
Severity ?
No CVSS data available.
CWE
  • CWE-269 - Improper Privilege Management (CWE-269)
Assigner
References
Impacted products
Vendor Product Version
Ubiquiti Networks EdgeRouter X Affected: EdgeOS v1.9.1.1 and prior
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T13:25:17.246Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://hackerone.com/reports/242407"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://community.ubnt.com/t5/EdgeMAX-Updates-Blog/EdgeMAX-EdgeRouter-software-security-release-v1-9-7-hotfix-3/ba-p/2054117"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "EdgeRouter X",
          "vendor": "Ubiquiti Networks",
          "versions": [
            {
              "status": "affected",
              "version": "EdgeOS v1.9.1.1 and prior"
            }
          ]
        }
      ],
      "datePublic": "2017-09-06T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Ubiquiti Networks EdgeOS version 1.9.1.1 and prior suffer from an Improper Privilege Management vulnerability due to the lack of protection of the file system leading to sensitive information being exposed. An attacker with access to an operator (read-only) account could escalate privileges to admin (root) access in the system."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-269",
              "description": "Improper Privilege Management (CWE-269)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-03-22T13:57:01",
        "orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
        "shortName": "hackerone"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://hackerone.com/reports/242407"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://community.ubnt.com/t5/EdgeMAX-Updates-Blog/EdgeMAX-EdgeRouter-software-security-release-v1-9-7-hotfix-3/ba-p/2054117"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "support@hackerone.com",
          "DATE_PUBLIC": "2017-09-06T00:00:00",
          "ID": "CVE-2017-0935",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "EdgeRouter X",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "EdgeOS v1.9.1.1 and prior"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Ubiquiti Networks"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Ubiquiti Networks EdgeOS version 1.9.1.1 and prior suffer from an Improper Privilege Management vulnerability due to the lack of protection of the file system leading to sensitive information being exposed. An attacker with access to an operator (read-only) account could escalate privileges to admin (root) access in the system."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Improper Privilege Management (CWE-269)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://hackerone.com/reports/242407",
              "refsource": "MISC",
              "url": "https://hackerone.com/reports/242407"
            },
            {
              "name": "https://community.ubnt.com/t5/EdgeMAX-Updates-Blog/EdgeMAX-EdgeRouter-software-security-release-v1-9-7-hotfix-3/ba-p/2054117",
              "refsource": "CONFIRM",
              "url": "https://community.ubnt.com/t5/EdgeMAX-Updates-Blog/EdgeMAX-EdgeRouter-software-security-release-v1-9-7-hotfix-3/ba-p/2054117"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
    "assignerShortName": "hackerone",
    "cveId": "CVE-2017-0935",
    "datePublished": "2018-03-22T14:00:00Z",
    "dateReserved": "2016-11-30T00:00:00",
    "dateUpdated": "2024-09-17T01:11:19.422Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-5265 (GCVE-0-2018-5265)

Vulnerability from nvd – Published: 2019-06-07 14:59 – Updated: 2024-08-05 05:33
VLAI?
Summary
Ubiquiti EdgeOS 1.9.1 on EdgeRouter Lite devices allows remote attackers to execute arbitrary code with admin credentials, because /opt/vyatta/share/vyatta-cfg/templates/system/static-host-mapping/host-name/node.def does not sanitize the 'alias' or 'ips' parameter for shell metacharacters.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T05:33:44.365Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.red4sec.com/cve/edgerouter_lite.txt"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Ubiquiti EdgeOS 1.9.1 on EdgeRouter Lite devices allows remote attackers to execute arbitrary code with admin credentials, because /opt/vyatta/share/vyatta-cfg/templates/system/static-host-mapping/host-name/node.def does not sanitize the \u0027alias\u0027 or \u0027ips\u0027 parameter for shell metacharacters."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-06-07T14:59:43",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.red4sec.com/cve/edgerouter_lite.txt"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2018-5265",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Ubiquiti EdgeOS 1.9.1 on EdgeRouter Lite devices allows remote attackers to execute arbitrary code with admin credentials, because /opt/vyatta/share/vyatta-cfg/templates/system/static-host-mapping/host-name/node.def does not sanitize the \u0027alias\u0027 or \u0027ips\u0027 parameter for shell metacharacters."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.red4sec.com/cve/edgerouter_lite.txt",
              "refsource": "MISC",
              "url": "https://www.red4sec.com/cve/edgerouter_lite.txt"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2018-5265",
    "datePublished": "2019-06-07T14:59:43",
    "dateReserved": "2018-01-07T00:00:00",
    "dateUpdated": "2024-08-05T05:33:44.365Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-0935 (GCVE-0-2017-0935)

Vulnerability from nvd – Published: 2018-03-22 14:00 – Updated: 2024-09-17 01:11
VLAI?
Summary
Ubiquiti Networks EdgeOS version 1.9.1.1 and prior suffer from an Improper Privilege Management vulnerability due to the lack of protection of the file system leading to sensitive information being exposed. An attacker with access to an operator (read-only) account could escalate privileges to admin (root) access in the system.
Severity ?
No CVSS data available.
CWE
  • CWE-269 - Improper Privilege Management (CWE-269)
Assigner
References
Impacted products
Vendor Product Version
Ubiquiti Networks EdgeRouter X Affected: EdgeOS v1.9.1.1 and prior
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T13:25:17.246Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://hackerone.com/reports/242407"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://community.ubnt.com/t5/EdgeMAX-Updates-Blog/EdgeMAX-EdgeRouter-software-security-release-v1-9-7-hotfix-3/ba-p/2054117"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "EdgeRouter X",
          "vendor": "Ubiquiti Networks",
          "versions": [
            {
              "status": "affected",
              "version": "EdgeOS v1.9.1.1 and prior"
            }
          ]
        }
      ],
      "datePublic": "2017-09-06T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Ubiquiti Networks EdgeOS version 1.9.1.1 and prior suffer from an Improper Privilege Management vulnerability due to the lack of protection of the file system leading to sensitive information being exposed. An attacker with access to an operator (read-only) account could escalate privileges to admin (root) access in the system."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-269",
              "description": "Improper Privilege Management (CWE-269)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-03-22T13:57:01",
        "orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
        "shortName": "hackerone"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://hackerone.com/reports/242407"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://community.ubnt.com/t5/EdgeMAX-Updates-Blog/EdgeMAX-EdgeRouter-software-security-release-v1-9-7-hotfix-3/ba-p/2054117"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "support@hackerone.com",
          "DATE_PUBLIC": "2017-09-06T00:00:00",
          "ID": "CVE-2017-0935",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "EdgeRouter X",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "EdgeOS v1.9.1.1 and prior"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Ubiquiti Networks"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Ubiquiti Networks EdgeOS version 1.9.1.1 and prior suffer from an Improper Privilege Management vulnerability due to the lack of protection of the file system leading to sensitive information being exposed. An attacker with access to an operator (read-only) account could escalate privileges to admin (root) access in the system."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Improper Privilege Management (CWE-269)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://hackerone.com/reports/242407",
              "refsource": "MISC",
              "url": "https://hackerone.com/reports/242407"
            },
            {
              "name": "https://community.ubnt.com/t5/EdgeMAX-Updates-Blog/EdgeMAX-EdgeRouter-software-security-release-v1-9-7-hotfix-3/ba-p/2054117",
              "refsource": "CONFIRM",
              "url": "https://community.ubnt.com/t5/EdgeMAX-Updates-Blog/EdgeMAX-EdgeRouter-software-security-release-v1-9-7-hotfix-3/ba-p/2054117"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
    "assignerShortName": "hackerone",
    "cveId": "CVE-2017-0935",
    "datePublished": "2018-03-22T14:00:00Z",
    "dateReserved": "2016-11-30T00:00:00",
    "dateUpdated": "2024-09-17T01:11:19.422Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}