All the vulnerabilites related to siemens - en100_ethernet_module_with_firmware_variant_iec_61850
Vulnerability from fkie_nvd
Published
2019-03-21 16:00
Modified
2024-11-21 03:52
Summary
A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module (All versions < V4.35), Firmware variant MODBUS TCP for EN100 Ethernet module (All versions), Firmware variant DNP3 TCP for EN100 Ethernet module (All versions), Firmware variant IEC104 for EN100 Ethernet module (All versions), Firmware variant Profinet IO for EN100 Ethernet module (All versions), SIPROTEC 5 relays with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions < V7.82), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions < V7.58). Specially crafted packets to port 102/tcp could cause a denial-of-service condition in the affected products. A manual restart is required to recover the EN100 module functionality of the affected devices. Successful exploitation requires an attacker with network access to send multiple packets to the affected products or modules. As a precondition the IEC 61850-MMS communication needs to be activated on the affected products or modules. No user interaction or privileges are required to exploit the vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the network functionality of the device, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_with_cpu_variant_cp100:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5702CB4F-7215-4E5D-99DF-457DE13F453E",
              "versionEndExcluding": "7.82",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_with_cpu_variant_cp200:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1D470323-A8F4-4029-93EC-C6FD86344CDD",
              "versionEndExcluding": "7.58",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_5_with_cpu_variant_cp300:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "696274F6-2529-43ED-AD59-EE03B2412920",
              "versionEndExcluding": "7.82",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6md85:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "23076116-128D-4366-B5BC-B965001FE356",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:6md86:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3457758B-A04D-4544-B0FA-DF87AA11D8FE",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7ke85:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "751F0BFE-216F-4620-BD5A-451B5F49C09C",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7sa82:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AF247CA0-37E1-40DF-96F5-9F00128EA250",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7sa86:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EDD3C99B-CDD8-4919-BE72-73814C2642A4",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7sa87:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DBE6CCA9-A246-4EB2-A57B-FE6823A9E3FD",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7sd82:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E11B4A68-F533-4AC0-80A9-7374FDFE2DEA",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7sd86:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "73F8D692-F268-45A4-9348-C67890A58881",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7sd87:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3C5A3FFD-17AD-4820-97D3-2F093BD5F322",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7sj82:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5739872A-E271-48BB-ABB5-17608E81AE7A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7sj85:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "ECC6417D-2C81-4654-B7FF-6C3E1B709962",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7sj86:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C52A6630-46F3-4113-B5E8-F5BAB7801CB0",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7sk82:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "088AC7F2-4FF3-4EF9-A111-D47DB859ECA1",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7sk85:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "73DD95AC-9B8F-43CD-9483-2BB9C4E86376",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7sl82:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8A9F05D9-C1DF-4D73-8634-239ABFE526DB",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7sl86:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C6662F7-5E3D-43A8-9984-EF1540BC917B",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7sl87:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E122323B-A42B-4DAB-A071-ACF76DC45E28",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7ss85:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5877387C-E05B-4231-9016-01FE7B197589",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7um85:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AAA9E810-2C00-4721-B3A6-E7CD7184BA24",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7ut82:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2E959A8E-21D1-4950-974B-A89693C14DC9",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7ut85:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DA075D19-21BF-4A7C-87B8-6A9D99799826",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7ut86:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7AC0D445-9A9B-4799-8B83-8B15821A6CC1",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7ut87:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D2A73860-76C5-435B-8150-1EABF644ADA0",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:7vk87:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5D9FD3B7-C7F7-41C1-9290-411F9D912D00",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:en100_ethernet_module_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "04955058-63F4-41FE-9F38-C90D89795CD4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:en100_ethernet_module_with_firmware_variant_dnp3_tcp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "90D74353-23C1-4FD7-A697-0303C778C2B2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:en100_ethernet_module_with_firmware_variant_iec_61850:4.35:*:*:*:*:*:*:*",
              "matchCriteriaId": "C8A66524-CF2E-4296-8795-DF2A1A2AA7D5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:en100_ethernet_module_with_firmware_variant_iec104:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E7BCD7E1-C8FA-4403-964C-5B255030DE75",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:en100_ethernet_module_with_firmware_variant_modbus_tcp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9C9581F1-DF4A-4DF7-A445-4D943475E50B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:en100_ethernet_module_with_firmware_variant_profinet_io:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "40CEAECA-7A4C-4773-8A1B-9648F6A647B8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:en100_ethernet_module:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DAC429FD-7148-4A68-AA81-8FBADA588F4E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module (All versions \u003c V4.35), Firmware variant MODBUS TCP for EN100 Ethernet module (All versions), Firmware variant DNP3 TCP for EN100 Ethernet module (All versions), Firmware variant IEC104 for EN100 Ethernet module (All versions), Firmware variant Profinet IO for EN100 Ethernet module (All versions), SIPROTEC 5 relays with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions \u003c V7.82), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions \u003c V7.58). Specially crafted packets to port 102/tcp could cause a denial-of-service condition in the affected products. A manual restart is required to recover the EN100 module functionality of the affected devices. Successful exploitation requires an attacker with network access to send multiple packets to the affected products or modules. As a precondition the IEC 61850-MMS communication needs to be activated on the affected products or modules. No user interaction or privileges are required to exploit the vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the network functionality of the device, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en la variante de firmware IEC 61850 para el m\u00f3dulo de Ethernet EN100 (todas las versiones anteriores a la V4.35), la variante de firmware MODBUS TCP para el m\u00f3dulo de Ethernet EN100 (todas las versiones), la variante de firmware DNP3 TCP para el m\u00f3dulo de Ethernet EN100 (todas las versiones), la variante de firmware IEC104 para el m\u00f3dulo de Ethernet EN100 para el m\u00f3dulo de Ethernet (todas las versiones), la variante de firmware Profinet IO para el m\u00f3dulo de Ethernet EN100 para el m\u00f3dulo de Ethernet (todas las versiones), los relays SIPROTEC 5 con las variantes de CPU CP300 y CP100 y los respectivos m\u00f3dulos de comunicaci\u00f3n Ethernet (todas las versiones anteriores a la V7.82) y los relays SIPROTEC 5 con las variantes de CPU CP200 y los respectivos m\u00f3dulos de comunicaci\u00f3n Ethernet (todas las versiones anteriores a la V7.58). Los paquetes especialmente manipulados enviados al puerto 102/tcp podr\u00edan provocar una denegaci\u00f3n de servicio (DoS) en los productos afectados. Se necesita un reinicio manual para recuperar la funcionalidad del m\u00f3dulo EN100 de los dispositivos afectados. Su explotaci\u00f3n con \u00e9xito requiere que un atacante con acceso de red env\u00ede m\u00faltiples paquetes a los productos o m\u00f3dulos afectados. Como prerrequisito, la comunicaci\u00f3n IEC 61850-MMS necesita activarse en los productos o m\u00f3dulos afectados. No se requiere interacci\u00f3n o privilegios del usuario para explotar esta vulnerabilidad. La vulnerabilidad podr\u00eda permitir una denegaci\u00f3n de servicio (DoS) en la funcionalidad de red del dispositivo, comprometiendo la disponibilidad del sistema. En el momento de la publicaci\u00f3n del advisory, no se conoce ninguna explotaci\u00f3n p\u00fablica de la vulnerabilidad de seguridad."
    }
  ],
  "id": "CVE-2018-16563",
  "lastModified": "2024-11-21T03:52:59.153",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 4.3,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 5.9,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 2.2,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2019-03-21T16:00:22.420",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-104088.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-104088.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2019-12-12 19:15
Modified
2024-11-21 04:25
Summary
A vulnerability has been identified in EN100 Ethernet module DNP3 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.37), EN100 Ethernet module IEC104 variant (All versions), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). An unauthorized user could exploit a buffer overflow vulnerability in the webserver. Specially crafted packets sent could cause a Denial-of-Service condition and if certain conditions are met, the affected devices must be restarted manually to fully recover. At the time of advisory publication no public exploitation of this security vulnerability was known.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:en100_ethernet_module_with_firmware_variant_dnp3_tcp:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AF72E8A5-4A16-4CF8-9E61-AFFC03601E6E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:en100_ethernet_module_with_firmware_variant_iec_61850:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5B8072EE-0802-4BDF-AFD7-40903FD1E745",
              "versionEndExcluding": "4.37",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:en100_ethernet_module_with_firmware_variant_iec104:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F4A4DECE-7ECB-4E8B-8617-75FDFE98FCA4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:en100_ethernet_module_with_firmware_variant_modbus_tcp:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1E6BB145-4C7D-4E30-8058-A809DBB65735",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:en100_ethernet_module_with_firmware_variant_profinet_io:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "49004945-B9EA-4AFE-8B95-CC7C8F80FAD6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:en100_ethernet_module:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DAC429FD-7148-4A68-AA81-8FBADA588F4E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in EN100 Ethernet module DNP3 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions \u003c V4.37), EN100 Ethernet module IEC104 variant (All versions), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). An unauthorized user could exploit a buffer overflow vulnerability in the webserver. Specially crafted packets sent could cause a Denial-of-Service condition and if certain conditions are met, the affected devices must be restarted manually to fully recover. At the time of advisory publication no public exploitation of this security vulnerability was known."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en la variante DNP3 del m\u00f3dulo EN100 Ethernet (todas las versiones), la variante IEC 61850 del m\u00f3dulo EN100 Ethernet (todas las versiones anteriores a V4.37), la variante IEC104 del m\u00f3dulo EN100 Ethernet (todas las versiones), la variante Modbus TCP del m\u00f3dulo EN100 Ethernet (todas las versiones), la variante PROFINET IO del m\u00f3dulo EN100 Ethernet (todas las versiones). Un usuario no autorizado podr\u00eda explotar una vulnerabilidad de desbordamiento del b\u00fafer en el servidor web. Los paquetes especialmente dise\u00f1ados enviados podr\u00edan causar una condici\u00f3n de Denegaci\u00f3n de Servicio y, si se cumplen determinadas condiciones, los dispositivos afectados deben ser reiniciados manualmente para recuperarse por completo. Al momento de la publicaci\u00f3n del aviso, no era conocida la explotaci\u00f3n p\u00fablica de esta vulnerabilidad de seguridad."
    }
  ],
  "id": "CVE-2019-13942",
  "lastModified": "2024-11-21T04:25:44.567",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 5.0,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2019-12-12T19:15:14.997",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-418979.pdf"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.us-cert.gov/ics/advisories/icsa-19-344-07"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-418979.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.us-cert.gov/ics/advisories/icsa-19-344-07"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2019-12-12 19:15
Modified
2024-11-21 04:25
Summary
A vulnerability has been identified in EN100 Ethernet module DNP3 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.37), EN100 Ethernet module IEC104 variant (All versions), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). The web interface could allow Cross-Site Scripting (XSS) attacks if an attacker is able to modify content of particular web pages, causing the application to behave in unexpected ways for legitimate users. Successful exploitation does not require for an attacker to be authenticated to the web interface. This could allow the attacker to read or modify contents of the web application. At the time of advisory publication no public exploitation of this security. vulnerability was known.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:en100_ethernet_module_with_firmware_variant_dnp3_tcp:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AF72E8A5-4A16-4CF8-9E61-AFFC03601E6E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:en100_ethernet_module_with_firmware_variant_iec_61850:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5B8072EE-0802-4BDF-AFD7-40903FD1E745",
              "versionEndExcluding": "4.37",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:en100_ethernet_module_with_firmware_variant_iec104:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F4A4DECE-7ECB-4E8B-8617-75FDFE98FCA4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:en100_ethernet_module_with_firmware_variant_modbus_tcp:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1E6BB145-4C7D-4E30-8058-A809DBB65735",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:en100_ethernet_module_with_firmware_variant_profinet_io:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "49004945-B9EA-4AFE-8B95-CC7C8F80FAD6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:en100_ethernet_module:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DAC429FD-7148-4A68-AA81-8FBADA588F4E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in EN100 Ethernet module DNP3 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions \u003c V4.37), EN100 Ethernet module IEC104 variant (All versions), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). The web interface could allow Cross-Site Scripting (XSS) attacks if an attacker is able to modify content of particular web pages, causing the application to behave in unexpected ways for legitimate users. Successful exploitation does not require for an attacker to be authenticated to the web interface. This could allow the attacker to read or modify contents of the web application. At the time of advisory publication no public exploitation of this security. vulnerability was known."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en la variante DNP3 del m\u00f3dulo EN100 Ethernet (todas las versiones), la variante IEC 61850 del m\u00f3dulo EN100 Ethernet (todas las versiones anteriores a V4.37), la variante IEC104 del m\u00f3dulo EN100 Ethernet (todas las versiones), la variante Modbus TCP del m\u00f3dulo EN100 Ethernet (todas las versiones), la variante PROFINET IO del m\u00f3dulo EN100 Ethernet (todas las versiones). La interfaz web podr\u00eda permitir ataques de tipo Cross-Site Scripting (XSS) si un atacante puede modificar el contenido de p\u00e1ginas web particulares, causando que la aplicaci\u00f3n se comporte de manera inesperada para usuarios leg\u00edtimos. Una explotaci\u00f3n con \u00e9xito no requiere que un atacante se autentique en la interfaz web. Esto podr\u00eda permitir al atacante leer o modificar el contenido de la aplicaci\u00f3n web. Al momento de la publicaci\u00f3n del aviso no hay explotaci\u00f3n p\u00fablica de esta seguridad. La vulnerabilidad era conocida."
    }
  ],
  "id": "CVE-2019-13943",
  "lastModified": "2024-11-21T04:25:44.693",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 4.3,
          "confidentialityImpact": "NONE",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 6.1,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 2.7,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2019-12-12T19:15:15.077",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-418979.pdf"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.us-cert.gov/ics/advisories/icsa-19-344-07"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-418979.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.us-cert.gov/ics/advisories/icsa-19-344-07"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2019-12-12 19:15
Modified
2024-11-21 04:25
Summary
A vulnerability has been identified in EN100 Ethernet module DNP3 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.37), EN100 Ethernet module IEC104 variant (All versions), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). A vulnerability in the integrated web server of the affected devices could allow unauthorized attackers to obtain sensitive information about the device, including logs and configurations. At the time of advisory publication no public exploitation of this security vulnerability was known.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:en100_ethernet_module_with_firmware_variant_dnp3_tcp:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AF72E8A5-4A16-4CF8-9E61-AFFC03601E6E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:en100_ethernet_module_with_firmware_variant_iec_61850:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5B8072EE-0802-4BDF-AFD7-40903FD1E745",
              "versionEndExcluding": "4.37",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:en100_ethernet_module_with_firmware_variant_iec104:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F4A4DECE-7ECB-4E8B-8617-75FDFE98FCA4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:en100_ethernet_module_with_firmware_variant_modbus_tcp:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1E6BB145-4C7D-4E30-8058-A809DBB65735",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:en100_ethernet_module_with_firmware_variant_profinet_io:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "49004945-B9EA-4AFE-8B95-CC7C8F80FAD6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:en100_ethernet_module:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DAC429FD-7148-4A68-AA81-8FBADA588F4E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in EN100 Ethernet module DNP3 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions \u003c V4.37), EN100 Ethernet module IEC104 variant (All versions), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). A vulnerability in the integrated web server of the affected devices could allow unauthorized attackers to obtain sensitive information about the device, including logs and configurations. At the time of advisory publication no public exploitation of this security vulnerability was known."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en la variante DNP3 del m\u00f3dulo EN100 Ethernet (todas las versiones), la variante IEC 61850 del m\u00f3dulo EN100 Ethernet (todas las versiones anteriores a V4.37), la variante IEC104 del m\u00f3dulo EN100 Ethernet (todas las versiones), la variante Modbus TCP del m\u00f3dulo EN100 Ethernet (todas las versiones), la variante PROFINET IO del m\u00f3dulo EN100 Ethernet (todas las versiones). Una vulnerabilidad en el servidor web integrado de los dispositivos afectados podr\u00eda permitir a atacantes no autorizados obtener informaci\u00f3n confidencial sobre el dispositivo, incluyendo registros y configuraciones. Al momento de la publicaci\u00f3n del aviso, no era conocida la explotaci\u00f3n p\u00fablica de esta vulnerabilidad de seguridad."
    }
  ],
  "id": "CVE-2019-13944",
  "lastModified": "2024-11-21T04:25:44.813",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 5.0,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 5.3,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 1.4,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2019-12-12T19:15:15.157",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-418979.pdf"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.us-cert.gov/ics/advisories/icsa-19-344-07"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-418979.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.us-cert.gov/ics/advisories/icsa-19-344-07"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-23"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-22"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

cve-2018-16563
Vulnerability from cvelistv5
Published
2019-03-21 14:57
Modified
2024-08-05 10:24
Severity ?
Summary
A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module (All versions < V4.35), Firmware variant MODBUS TCP for EN100 Ethernet module (All versions), Firmware variant DNP3 TCP for EN100 Ethernet module (All versions), Firmware variant IEC104 for EN100 Ethernet module (All versions), Firmware variant Profinet IO for EN100 Ethernet module (All versions), SIPROTEC 5 relays with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions < V7.82), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions < V7.58). Specially crafted packets to port 102/tcp could cause a denial-of-service condition in the affected products. A manual restart is required to recover the EN100 module functionality of the affected devices. Successful exploitation requires an attacker with network access to send multiple packets to the affected products or modules. As a precondition the IEC 61850-MMS communication needs to be activated on the affected products or modules. No user interaction or privileges are required to exploit the vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the network functionality of the device, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.
References
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T10:24:32.996Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-104088.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Firmware variant IEC 61850 for EN100 Ethernet module",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.35"
            }
          ]
        },
        {
          "product": "Firmware variant MODBUS TCP for EN100 Ethernet module",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "Firmware variant DNP3 TCP for EN100 Ethernet module",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "Firmware variant IEC104 for EN100 Ethernet module",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "Firmware variant Profinet IO for EN100 Ethernet module",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIPROTEC 5 relays with CPU variants CP300 and CP100 and the respective Ethernet communication modules",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.82"
            }
          ]
        },
        {
          "product": "SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.58"
            }
          ]
        }
      ],
      "datePublic": "2019-02-12T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module (All versions \u003c V4.35), Firmware variant MODBUS TCP for EN100 Ethernet module (All versions), Firmware variant DNP3 TCP for EN100 Ethernet module (All versions), Firmware variant IEC104 for EN100 Ethernet module (All versions), Firmware variant Profinet IO for EN100 Ethernet module (All versions), SIPROTEC 5 relays with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions \u003c V7.82), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions \u003c V7.58). Specially crafted packets to port 102/tcp could cause a denial-of-service condition in the affected products. A manual restart is required to recover the EN100 module functionality of the affected devices. Successful exploitation requires an attacker with network access to send multiple packets to the affected products or modules. As a precondition the IEC 61850-MMS communication needs to be activated on the affected products or modules. No user interaction or privileges are required to exploit the vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the network functionality of the device, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Other",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-03-21T14:57:36",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-104088.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2018-16563",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Firmware variant IEC 61850 for EN100 Ethernet module",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.35"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Firmware variant MODBUS TCP for EN100 Ethernet module",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Firmware variant DNP3 TCP for EN100 Ethernet module",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Firmware variant IEC104 for EN100 Ethernet module",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Firmware variant Profinet IO for EN100 Ethernet module",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIPROTEC 5 relays with CPU variants CP300 and CP100 and the respective Ethernet communication modules",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.82"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.58"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module (All versions \u003c V4.35), Firmware variant MODBUS TCP for EN100 Ethernet module (All versions), Firmware variant DNP3 TCP for EN100 Ethernet module (All versions), Firmware variant IEC104 for EN100 Ethernet module (All versions), Firmware variant Profinet IO for EN100 Ethernet module (All versions), SIPROTEC 5 relays with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions \u003c V7.82), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions \u003c V7.58). Specially crafted packets to port 102/tcp could cause a denial-of-service condition in the affected products. A manual restart is required to recover the EN100 module functionality of the affected devices. Successful exploitation requires an attacker with network access to send multiple packets to the affected products or modules. As a precondition the IEC 61850-MMS communication needs to be activated on the affected products or modules. No user interaction or privileges are required to exploit the vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the network functionality of the device, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Other"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-104088.pdf",
              "refsource": "CONFIRM",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-104088.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2018-16563",
    "datePublished": "2019-03-21T14:57:36",
    "dateReserved": "2018-09-06T00:00:00",
    "dateUpdated": "2024-08-05T10:24:32.996Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2019-13943
Vulnerability from cvelistv5
Published
2019-12-12 19:08
Modified
2024-08-05 00:05
Severity ?
Summary
A vulnerability has been identified in EN100 Ethernet module DNP3 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.37), EN100 Ethernet module IEC104 variant (All versions), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). The web interface could allow Cross-Site Scripting (XSS) attacks if an attacker is able to modify content of particular web pages, causing the application to behave in unexpected ways for legitimate users. Successful exploitation does not require for an attacker to be authenticated to the web interface. This could allow the attacker to read or modify contents of the web application. At the time of advisory publication no public exploitation of this security. vulnerability was known.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T00:05:44.073Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-418979.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/icsa-19-344-07"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "EN100 Ethernet module DNP3 variant",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "EN100 Ethernet module IEC 61850 variant",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.37"
            }
          ]
        },
        {
          "product": "EN100 Ethernet module IEC104 variant",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "EN100 Ethernet module Modbus TCP variant",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "EN100 Ethernet module PROFINET IO variant",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in EN100 Ethernet module DNP3 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions \u003c V4.37), EN100 Ethernet module IEC104 variant (All versions), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). The web interface could allow Cross-Site Scripting (XSS) attacks if an attacker is able to modify content of particular web pages, causing the application to behave in unexpected ways for legitimate users. Successful exploitation does not require for an attacker to be authenticated to the web interface. This could allow the attacker to read or modify contents of the web application. At the time of advisory publication no public exploitation of this security. vulnerability was known."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-01-16T15:35:24",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-418979.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsa-19-344-07"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2019-13943",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "EN100 Ethernet module DNP3 variant",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "EN100 Ethernet module IEC 61850 variant",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.37"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "EN100 Ethernet module IEC104 variant",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "EN100 Ethernet module Modbus TCP variant",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "EN100 Ethernet module PROFINET IO variant",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in EN100 Ethernet module DNP3 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions \u003c V4.37), EN100 Ethernet module IEC104 variant (All versions), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). The web interface could allow Cross-Site Scripting (XSS) attacks if an attacker is able to modify content of particular web pages, causing the application to behave in unexpected ways for legitimate users. Successful exploitation does not require for an attacker to be authenticated to the web interface. This could allow the attacker to read or modify contents of the web application. At the time of advisory publication no public exploitation of this security. vulnerability was known."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-418979.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-418979.pdf"
            },
            {
              "name": "https://www.us-cert.gov/ics/advisories/icsa-19-344-07",
              "refsource": "MISC",
              "url": "https://www.us-cert.gov/ics/advisories/icsa-19-344-07"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2019-13943",
    "datePublished": "2019-12-12T19:08:46",
    "dateReserved": "2019-07-18T00:00:00",
    "dateUpdated": "2024-08-05T00:05:44.073Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2019-13944
Vulnerability from cvelistv5
Published
2019-12-12 19:08
Modified
2024-08-05 00:05
Severity ?
Summary
A vulnerability has been identified in EN100 Ethernet module DNP3 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.37), EN100 Ethernet module IEC104 variant (All versions), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). A vulnerability in the integrated web server of the affected devices could allow unauthorized attackers to obtain sensitive information about the device, including logs and configurations. At the time of advisory publication no public exploitation of this security vulnerability was known.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T00:05:43.799Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-418979.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/icsa-19-344-07"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "EN100 Ethernet module DNP3 variant",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "EN100 Ethernet module IEC 61850 variant",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.37"
            }
          ]
        },
        {
          "product": "EN100 Ethernet module IEC104 variant",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "EN100 Ethernet module Modbus TCP variant",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "EN100 Ethernet module PROFINET IO variant",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in EN100 Ethernet module DNP3 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions \u003c V4.37), EN100 Ethernet module IEC104 variant (All versions), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). A vulnerability in the integrated web server of the affected devices could allow unauthorized attackers to obtain sensitive information about the device, including logs and configurations. At the time of advisory publication no public exploitation of this security vulnerability was known."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-23",
              "description": "CWE-23: Relative Path Traversal",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-01-16T15:35:24",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-418979.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsa-19-344-07"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2019-13944",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "EN100 Ethernet module DNP3 variant",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "EN100 Ethernet module IEC 61850 variant",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.37"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "EN100 Ethernet module IEC104 variant",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "EN100 Ethernet module Modbus TCP variant",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "EN100 Ethernet module PROFINET IO variant",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in EN100 Ethernet module DNP3 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions \u003c V4.37), EN100 Ethernet module IEC104 variant (All versions), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). A vulnerability in the integrated web server of the affected devices could allow unauthorized attackers to obtain sensitive information about the device, including logs and configurations. At the time of advisory publication no public exploitation of this security vulnerability was known."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-23: Relative Path Traversal"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-418979.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-418979.pdf"
            },
            {
              "name": "https://www.us-cert.gov/ics/advisories/icsa-19-344-07",
              "refsource": "MISC",
              "url": "https://www.us-cert.gov/ics/advisories/icsa-19-344-07"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2019-13944",
    "datePublished": "2019-12-12T19:08:46",
    "dateReserved": "2019-07-18T00:00:00",
    "dateUpdated": "2024-08-05T00:05:43.799Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2019-13942
Vulnerability from cvelistv5
Published
2019-12-12 19:08
Modified
2024-08-05 00:05
Severity ?
Summary
A vulnerability has been identified in EN100 Ethernet module DNP3 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.37), EN100 Ethernet module IEC104 variant (All versions), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). An unauthorized user could exploit a buffer overflow vulnerability in the webserver. Specially crafted packets sent could cause a Denial-of-Service condition and if certain conditions are met, the affected devices must be restarted manually to fully recover. At the time of advisory publication no public exploitation of this security vulnerability was known.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T00:05:44.006Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-418979.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/icsa-19-344-07"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "EN100 Ethernet module DNP3 variant",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "EN100 Ethernet module IEC 61850 variant",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.37"
            }
          ]
        },
        {
          "product": "EN100 Ethernet module IEC104 variant",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "EN100 Ethernet module Modbus TCP variant",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "EN100 Ethernet module PROFINET IO variant",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in EN100 Ethernet module DNP3 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions \u003c V4.37), EN100 Ethernet module IEC104 variant (All versions), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). An unauthorized user could exploit a buffer overflow vulnerability in the webserver. Specially crafted packets sent could cause a Denial-of-Service condition and if certain conditions are met, the affected devices must be restarted manually to fully recover. At the time of advisory publication no public exploitation of this security vulnerability was known."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-01-16T15:35:24",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-418979.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsa-19-344-07"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2019-13942",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "EN100 Ethernet module DNP3 variant",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "EN100 Ethernet module IEC 61850 variant",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.37"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "EN100 Ethernet module IEC104 variant",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "EN100 Ethernet module Modbus TCP variant",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "EN100 Ethernet module PROFINET IO variant",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in EN100 Ethernet module DNP3 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions \u003c V4.37), EN100 Ethernet module IEC104 variant (All versions), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). An unauthorized user could exploit a buffer overflow vulnerability in the webserver. Specially crafted packets sent could cause a Denial-of-Service condition and if certain conditions are met, the affected devices must be restarted manually to fully recover. At the time of advisory publication no public exploitation of this security vulnerability was known."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-418979.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-418979.pdf"
            },
            {
              "name": "https://www.us-cert.gov/ics/advisories/icsa-19-344-07",
              "refsource": "MISC",
              "url": "https://www.us-cert.gov/ics/advisories/icsa-19-344-07"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2019-13942",
    "datePublished": "2019-12-12T19:08:46",
    "dateReserved": "2019-07-18T00:00:00",
    "dateUpdated": "2024-08-05T00:05:44.006Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}