Search criteria

3 vulnerabilities found for epg5000_firmware by engeniustech

FKIE_CVE-2025-34035

Vulnerability from fkie_nvd - Published: 2025-06-24 01:15 - Updated: 2025-11-20 22:15
Severity ?
Summary
An OS command injection vulnerability exists in EnGenius EnShare Cloud Service version 1.4.11 and earlier. The usbinteract.cgi script fails to properly sanitize user input passed to the path parameter, allowing unauthenticated remote attackers to inject arbitrary shell commands. The injected commands are executed with root privileges, leading to full system compromise. Exploitation evidence was observed by the Shadowserver Foundation on 2024-12-05 UTC.
Impacted products
Vendor Product Version
engeniustech esr300_firmware 1.1.0.28
engeniustech esr300_firmware 1.3.1.42
engeniustech esr300_firmware 1.4.0
engeniustech esr300_firmware 1.4.1.28
engeniustech esr300_firmware 1.4.2
engeniustech esr300_firmware 1.4.7
engeniustech esr300_firmware 1.4.9
engeniustech esr300 -
engeniustech esr350_firmware 1.1.0.29
engeniustech esr350_firmware 1.3.1.41
engeniustech esr350_firmware 1.4.0
engeniustech esr350_firmware 1.4.2
engeniustech esr350_firmware 1.4.5
engeniustech esr350_firmware 1.4.9
engeniustech esr350_firmware 1.4.11
engeniustech esr350 -
engeniustech esr600_firmware 1.1.0.50
engeniustech esr600_firmware 1.2.1.46
engeniustech esr600_firmware 1.3.1.63
engeniustech esr600_firmware 1.4.0.23
engeniustech esr600_firmware 1.4.1
engeniustech esr600_firmware 1.4.2
engeniustech esr600_firmware 1.4.3
engeniustech esr600_firmware 1.4.5
engeniustech esr600_firmware 1.4.9
engeniustech esr600_firmware 1.4.11
engeniustech esr600 -
engeniustech esr900_firmware 1.1.0
engeniustech esr900_firmware 1.2.2.23
engeniustech esr900_firmware 1.3.0
engeniustech esr900_firmware 1.3.1.26
engeniustech esr900_firmware 1.3.5.18
engeniustech esr900_firmware 1.4.0
engeniustech esr900_firmware 1.4.3
engeniustech esr900_firmware 1.4.5
engeniustech esr900 -
engeniustech esr1200_firmware 1.1.0
engeniustech esr1200_firmware 1.3.1.34
engeniustech esr1200_firmware 1.4.1
engeniustech esr1200_firmware 1.4.3
engeniustech esr1200_firmware 1.4.5
engeniustech esr1200 -
engeniustech esr1750_firmware 1.1.0
engeniustech esr1750_firmware 1.2.2.27
engeniustech esr1750_firmware 1.3.0
engeniustech esr1750_firmware 1.3.1.34
engeniustech esr1750_firmware 1.4.0
engeniustech esr1750_firmware 1.4.1
engeniustech esr1750_firmware 1.4.3
engeniustech esr1750_firmware 1.4.5
engeniustech esr1750 -
engeniustech epg5000_firmware 1.2.0
engeniustech epg5000_firmware 1.3.0
engeniustech epg5000_firmware 1.3.2
engeniustech epg5000_firmware 1.3.3
engeniustech epg5000_firmware 1.3.3.17
engeniustech epg5000_firmware 1.3.7.20
engeniustech epg5000_firmware 1.3.9.21
engeniustech epg5000 -

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:engeniustech:esr300_firmware:1.1.0.28:*:*:*:*:*:*:*",
              "matchCriteriaId": "01334F44-2F36-4809-9087-21B9459FD71E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:engeniustech:esr300_firmware:1.3.1.42:*:*:*:*:*:*:*",
              "matchCriteriaId": "915E0D9B-A924-4AE8-B837-57CB4F4ACB22",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:engeniustech:esr300_firmware:1.4.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "B9C44CC9-6F20-4B99-AE68-C1E526233DF9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:engeniustech:esr300_firmware:1.4.1.28:*:*:*:*:*:*:*",
              "matchCriteriaId": "521FF3A0-8FA4-4A59-B00C-F0DEC4A4E778",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:engeniustech:esr300_firmware:1.4.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "FC3398A7-2BBD-4FDC-AA00-196563220F81",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:engeniustech:esr300_firmware:1.4.7:*:*:*:*:*:*:*",
              "matchCriteriaId": "FA1E3718-B4C2-49F4-83BA-4CB05BB5108C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:engeniustech:esr300_firmware:1.4.9:*:*:*:*:*:*:*",
              "matchCriteriaId": "FEF34250-F996-403E-9CFC-AC2F9496B9D3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:engeniustech:esr300:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D2FFE521-B6A9-4070-A91B-FDB1BD0FBD46",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:engeniustech:esr350_firmware:1.1.0.29:*:*:*:*:*:*:*",
              "matchCriteriaId": "38901E90-6040-48B9-B4BC-B0367DAD2C88",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:engeniustech:esr350_firmware:1.3.1.41:*:*:*:*:*:*:*",
              "matchCriteriaId": "19636B66-7BC4-4BED-B9B0-56B30E196A79",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:engeniustech:esr350_firmware:1.4.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "BDEE977B-876B-4870-9F95-58117BB77617",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:engeniustech:esr350_firmware:1.4.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "E9EAE034-F08E-4B1D-A57F-071870F47C10",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:engeniustech:esr350_firmware:1.4.5:*:*:*:*:*:*:*",
              "matchCriteriaId": "DB0400F1-CD4B-4256-BCEB-202495D48F4E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:engeniustech:esr350_firmware:1.4.9:*:*:*:*:*:*:*",
              "matchCriteriaId": "F9ED2DCF-59BE-4390-9804-AE8BA333BA7F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:engeniustech:esr350_firmware:1.4.11:*:*:*:*:*:*:*",
              "matchCriteriaId": "C1D7124D-153D-4DC5-8B74-567A998B6590",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:engeniustech:esr350:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "641FE70C-9DE5-436F-A23F-72A38DB4A282",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:engeniustech:esr600_firmware:1.1.0.50:*:*:*:*:*:*:*",
              "matchCriteriaId": "E540691D-3D97-49B8-8E20-C962093946CE",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:engeniustech:esr600_firmware:1.2.1.46:*:*:*:*:*:*:*",
              "matchCriteriaId": "9EA691B6-BAC5-4D6A-9AEB-29D9B2539DD1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:engeniustech:esr600_firmware:1.3.1.63:*:*:*:*:*:*:*",
              "matchCriteriaId": "90661049-6B4F-4867-A319-AC72B1725B70",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:engeniustech:esr600_firmware:1.4.0.23:*:*:*:*:*:*:*",
              "matchCriteriaId": "107428B5-06A6-4F4E-B351-4B465D1B83AF",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:engeniustech:esr600_firmware:1.4.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "7ACF9999-3B5D-47BB-8C7F-EE8374F202A7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:engeniustech:esr600_firmware:1.4.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "56D33DE8-4679-4FF1-90B1-FDCE26760347",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:engeniustech:esr600_firmware:1.4.3:*:*:*:*:*:*:*",
              "matchCriteriaId": "D65AB145-B93F-4432-9123-78C5A910023C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:engeniustech:esr600_firmware:1.4.5:*:*:*:*:*:*:*",
              "matchCriteriaId": "E783F09C-5698-4CA2-88B6-1BA08D854E6B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:engeniustech:esr600_firmware:1.4.9:*:*:*:*:*:*:*",
              "matchCriteriaId": "968F3619-0904-4866-A3BA-DC8973CC3342",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:engeniustech:esr600_firmware:1.4.11:*:*:*:*:*:*:*",
              "matchCriteriaId": "A64D257F-E3C0-40EB-993B-411779EFC161",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:engeniustech:esr600:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D6FD4A2C-A954-42E1-AA5F-1079DF273FE2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:engeniustech:esr900_firmware:1.1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE33B9D9-C987-4ED4-9074-CB9309428005",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:engeniustech:esr900_firmware:1.2.2.23:*:*:*:*:*:*:*",
              "matchCriteriaId": "95869E44-9D11-4DD8-A73D-2A1BEEA491C9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:engeniustech:esr900_firmware:1.3.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "6CD2F563-3CF7-4389-814F-0252EE15BA26",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:engeniustech:esr900_firmware:1.3.1.26:*:*:*:*:*:*:*",
              "matchCriteriaId": "F78A7329-9DAA-4DCF-AF4A-3CC463B2BC39",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:engeniustech:esr900_firmware:1.3.5.18:*:*:*:*:*:*:*",
              "matchCriteriaId": "12AD6D11-7D52-4A3B-8DA5-C1DB68C38760",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:engeniustech:esr900_firmware:1.4.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "537C5026-73D5-4BAC-A373-FC05F2A4A2EA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:engeniustech:esr900_firmware:1.4.3:*:*:*:*:*:*:*",
              "matchCriteriaId": "99F37AD1-9A0F-439B-9D37-EA94346A5A20",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:engeniustech:esr900_firmware:1.4.5:*:*:*:*:*:*:*",
              "matchCriteriaId": "EEAE5096-DF1D-40EB-B1BB-ECFEBF40E130",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:engeniustech:esr900:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2A260CFC-3B18-4541-806E-94EE562395E2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:engeniustech:esr1200_firmware:1.1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "A0EA408E-F053-4246-92B5-B020CCB15413",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:engeniustech:esr1200_firmware:1.3.1.34:*:*:*:*:*:*:*",
              "matchCriteriaId": "451C1304-51D1-4203-A0B9-48B9D4C74B0A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:engeniustech:esr1200_firmware:1.4.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "6424BADD-EC23-4A33-89CE-8AF72CB18E28",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:engeniustech:esr1200_firmware:1.4.3:*:*:*:*:*:*:*",
              "matchCriteriaId": "92865DE7-A769-4E39-9EE0-AA7F2D46534E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:engeniustech:esr1200_firmware:1.4.5:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9F8C66F-0E8D-404C-BCA9-F026F95BD7FF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:engeniustech:esr1200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5CE751B7-2530-4CBE-A00A-1F8C13F84834",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:engeniustech:esr1750_firmware:1.1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "D44C246A-DFBB-484D-ABA3-CCA289C6978D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:engeniustech:esr1750_firmware:1.2.2.27:*:*:*:*:*:*:*",
              "matchCriteriaId": "E33B9DF5-9719-48C1-BE50-FDED6F8FF566",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:engeniustech:esr1750_firmware:1.3.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "7E1D4CFD-DE05-45B7-ACF7-00C10EF178BD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:engeniustech:esr1750_firmware:1.3.1.34:*:*:*:*:*:*:*",
              "matchCriteriaId": "F44CDC69-8350-45B3-9769-1C0A284E8FB1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:engeniustech:esr1750_firmware:1.4.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "C18597C4-9AEE-4FAC-9249-CD68AC7C84C9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:engeniustech:esr1750_firmware:1.4.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "EF84C882-9982-4334-8C05-1CA80420E700",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:engeniustech:esr1750_firmware:1.4.3:*:*:*:*:*:*:*",
              "matchCriteriaId": "66B26B28-E5C4-4F74-84CD-3C8B620997BE",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:engeniustech:esr1750_firmware:1.4.5:*:*:*:*:*:*:*",
              "matchCriteriaId": "3E0113B2-E5DA-493A-8CBF-08CC7C1A34E0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:engeniustech:esr1750:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5CC87617-AB00-416A-BC73-ABBDD4A95AA9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:engeniustech:epg5000_firmware:1.2.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "C5E0C5F9-8859-483A-A7F5-55809BA3F4AE",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:engeniustech:epg5000_firmware:1.3.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "40601E1E-3C80-4BCF-B92A-ACD058097CEB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:engeniustech:epg5000_firmware:1.3.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "40402302-F6EE-4EA1-9925-991437978547",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:engeniustech:epg5000_firmware:1.3.3:*:*:*:*:*:*:*",
              "matchCriteriaId": "A29F0E0C-17AF-4664-B0D5-EB3FD8DF6F1F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:engeniustech:epg5000_firmware:1.3.3.17:*:*:*:*:*:*:*",
              "matchCriteriaId": "FF9D19CA-343D-4825-903C-7FD013492613",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:engeniustech:epg5000_firmware:1.3.7.20:*:*:*:*:*:*:*",
              "matchCriteriaId": "C5461F8A-9A98-4D99-AF72-FE52CDEE7FF2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:engeniustech:epg5000_firmware:1.3.9.21:*:*:*:*:*:*:*",
              "matchCriteriaId": "CF1E429B-4ED5-497F-926B-F8A876FC6D0D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:engeniustech:epg5000:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5D2D55FB-BF65-4201-9583-07B7C514664D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An OS command injection vulnerability exists in EnGenius EnShare Cloud Service version 1.4.11 and earlier. The usbinteract.cgi script fails to properly sanitize user input passed to the path parameter, allowing unauthenticated remote attackers to inject arbitrary shell commands. The injected commands are executed with root privileges, leading to full system compromise.\u00a0Exploitation evidence was observed by the Shadowserver Foundation on 2024-12-05 UTC."
    },
    {
      "lang": "es",
      "value": "Existe una vulnerabilidad de inyecci\u00f3n de comandos del sistema operativo en EnGenius EnShare Cloud Service versi\u00f3n 1.4.11 y anteriores. El script usbinteract.cgi no depura correctamente la entrada del usuario enviada al par\u00e1metro path, lo que permite a atacantes remotos no autenticados inyectar comandos de shell arbitrarios. Los comandos inyectados se ejecutan con privilegios de root, lo que compromete por completo el sistema."
    }
  ],
  "id": "CVE-2025-34035",
  "lastModified": "2025-11-20T22:15:56.183",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 10.0,
          "baseSeverity": "CRITICAL",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "NONE",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "HIGH",
          "subConfidentialityImpact": "HIGH",
          "subIntegrityImpact": "HIGH",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "disclosure@vulncheck.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-06-24T01:15:24.763",
  "references": [
    {
      "source": "disclosure@vulncheck.com",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://cxsecurity.com/issue/WLB-2017060050"
    },
    {
      "source": "disclosure@vulncheck.com",
      "tags": [
        "Broken Link"
      ],
      "url": "https://packetstormsecurity.com/files/142792"
    },
    {
      "source": "disclosure@vulncheck.com",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://vulncheck.com/advisories/engenius-enshare-iot-gigabit-cloud-service"
    },
    {
      "source": "disclosure@vulncheck.com",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://www.exploit-db.com/exploits/42114"
    },
    {
      "source": "disclosure@vulncheck.com",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://www.zeroscience.mk/en/vulnerabilities/ZSL-2017-5413.php"
    },
    {
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://www.zeroscience.mk/en/vulnerabilities/ZSL-2017-5413.php"
    }
  ],
  "sourceIdentifier": "disclosure@vulncheck.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-78"
        }
      ],
      "source": "disclosure@vulncheck.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-78"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

CVE-2025-34035 (GCVE-0-2025-34035)

Vulnerability from cvelistv5 – Published: 2025-06-24 01:00 – Updated: 2025-11-20 21:15 X_Known Exploited Vulnerability
VLAI?
Title
EnGenius EnShare IoT Gigabit Cloud Service Command Injection
Summary
An OS command injection vulnerability exists in EnGenius EnShare Cloud Service version 1.4.11 and earlier. The usbinteract.cgi script fails to properly sanitize user input passed to the path parameter, allowing unauthenticated remote attackers to inject arbitrary shell commands. The injected commands are executed with root privileges, leading to full system compromise. Exploitation evidence was observed by the Shadowserver Foundation on 2024-12-05 UTC.
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
Vendor Product Version
EnGenius EnShare IoT Gigabit Cloud Service Affected: 0 , ≤ 1.4.11 (semver)
Create a notification for this product.
Credits
Gjoko Krstic
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-34035",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-06-24T13:30:44.337841Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-24T13:30:48.459Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://www.zeroscience.mk/en/vulnerabilities/ZSL-2017-5413.php"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web Management Interface (usbinteract.cgi)"
          ],
          "product": "EnShare IoT Gigabit Cloud Service",
          "vendor": "EnGenius",
          "versions": [
            {
              "lessThanOrEqual": "1.4.11",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Gjoko Krstic"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An OS command injection vulnerability exists in EnGenius EnShare Cloud Service version 1.4.11 and earlier. The usbinteract.cgi script fails to properly sanitize user input passed to the path parameter, allowing unauthenticated remote attackers to inject arbitrary shell commands. The injected commands are executed with root privileges, leading to full system compromise.\u0026nbsp;Exploitation evidence was observed by the Shadowserver Foundation on 2024-12-05 UTC."
            }
          ],
          "value": "An OS command injection vulnerability exists in EnGenius EnShare Cloud Service version 1.4.11 and earlier. The usbinteract.cgi script fails to properly sanitize user input passed to the path parameter, allowing unauthenticated remote attackers to inject arbitrary shell commands. The injected commands are executed with root privileges, leading to full system compromise.\u00a0Exploitation evidence was observed by the Shadowserver Foundation on 2024-12-05 UTC."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-88",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-88 OS Command Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 10,
            "baseSeverity": "CRITICAL",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "HIGH",
            "subIntegrityImpact": "HIGH",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-20T21:15:28.292Z",
        "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "shortName": "VulnCheck"
      },
      "references": [
        {
          "tags": [
            "third-party-advisory",
            "exploit"
          ],
          "url": "https://www.zeroscience.mk/en/vulnerabilities/ZSL-2017-5413.php"
        },
        {
          "tags": [
            "third-party-advisory",
            "exploit"
          ],
          "url": "https://www.exploit-db.com/exploits/42114"
        },
        {
          "tags": [
            "third-party-advisory",
            "exploit"
          ],
          "url": "https://packetstormsecurity.com/files/142792"
        },
        {
          "tags": [
            "third-party-advisory",
            "exploit"
          ],
          "url": "https://cxsecurity.com/issue/WLB-2017060050"
        },
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vulncheck.com/advisories/engenius-enshare-iot-gigabit-cloud-service"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "tags": [
        "x_known-exploited-vulnerability"
      ],
      "title": "EnGenius EnShare IoT Gigabit Cloud Service Command Injection",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
    "assignerShortName": "VulnCheck",
    "cveId": "CVE-2025-34035",
    "datePublished": "2025-06-24T01:00:23.862Z",
    "dateReserved": "2025-04-15T19:15:22.546Z",
    "dateUpdated": "2025-11-20T21:15:28.292Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-34035 (GCVE-0-2025-34035)

Vulnerability from nvd – Published: 2025-06-24 01:00 – Updated: 2025-11-20 21:15 X_Known Exploited Vulnerability
VLAI?
Title
EnGenius EnShare IoT Gigabit Cloud Service Command Injection
Summary
An OS command injection vulnerability exists in EnGenius EnShare Cloud Service version 1.4.11 and earlier. The usbinteract.cgi script fails to properly sanitize user input passed to the path parameter, allowing unauthenticated remote attackers to inject arbitrary shell commands. The injected commands are executed with root privileges, leading to full system compromise. Exploitation evidence was observed by the Shadowserver Foundation on 2024-12-05 UTC.
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
Vendor Product Version
EnGenius EnShare IoT Gigabit Cloud Service Affected: 0 , ≤ 1.4.11 (semver)
Create a notification for this product.
Credits
Gjoko Krstic
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-34035",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-06-24T13:30:44.337841Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-24T13:30:48.459Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://www.zeroscience.mk/en/vulnerabilities/ZSL-2017-5413.php"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Web Management Interface (usbinteract.cgi)"
          ],
          "product": "EnShare IoT Gigabit Cloud Service",
          "vendor": "EnGenius",
          "versions": [
            {
              "lessThanOrEqual": "1.4.11",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Gjoko Krstic"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An OS command injection vulnerability exists in EnGenius EnShare Cloud Service version 1.4.11 and earlier. The usbinteract.cgi script fails to properly sanitize user input passed to the path parameter, allowing unauthenticated remote attackers to inject arbitrary shell commands. The injected commands are executed with root privileges, leading to full system compromise.\u0026nbsp;Exploitation evidence was observed by the Shadowserver Foundation on 2024-12-05 UTC."
            }
          ],
          "value": "An OS command injection vulnerability exists in EnGenius EnShare Cloud Service version 1.4.11 and earlier. The usbinteract.cgi script fails to properly sanitize user input passed to the path parameter, allowing unauthenticated remote attackers to inject arbitrary shell commands. The injected commands are executed with root privileges, leading to full system compromise.\u00a0Exploitation evidence was observed by the Shadowserver Foundation on 2024-12-05 UTC."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-88",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-88 OS Command Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 10,
            "baseSeverity": "CRITICAL",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "HIGH",
            "subIntegrityImpact": "HIGH",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-20T21:15:28.292Z",
        "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "shortName": "VulnCheck"
      },
      "references": [
        {
          "tags": [
            "third-party-advisory",
            "exploit"
          ],
          "url": "https://www.zeroscience.mk/en/vulnerabilities/ZSL-2017-5413.php"
        },
        {
          "tags": [
            "third-party-advisory",
            "exploit"
          ],
          "url": "https://www.exploit-db.com/exploits/42114"
        },
        {
          "tags": [
            "third-party-advisory",
            "exploit"
          ],
          "url": "https://packetstormsecurity.com/files/142792"
        },
        {
          "tags": [
            "third-party-advisory",
            "exploit"
          ],
          "url": "https://cxsecurity.com/issue/WLB-2017060050"
        },
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vulncheck.com/advisories/engenius-enshare-iot-gigabit-cloud-service"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "tags": [
        "x_known-exploited-vulnerability"
      ],
      "title": "EnGenius EnShare IoT Gigabit Cloud Service Command Injection",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
    "assignerShortName": "VulnCheck",
    "cveId": "CVE-2025-34035",
    "datePublished": "2025-06-24T01:00:23.862Z",
    "dateReserved": "2025-04-15T19:15:22.546Z",
    "dateUpdated": "2025-11-20T21:15:28.292Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}