Search criteria

18 vulnerabilities found for ex300_v2_firmware by totolink

FKIE_CVE-2022-32449

Vulnerability from fkie_nvd - Published: 2022-07-07 19:15 - Updated: 2024-11-21 07:06
Severity ?
Summary
TOTOLINK EX300_V2 V4.0.3c.7484 was discovered to contain a command injection vulnerability via the langType parameter in the setLanguageCfg function. This vulnerability is exploitable via a crafted MQTT data packet.
Impacted products
Vendor Product Version
totolink ex300_v2_firmware 4.0.3c.7484
totolink ex300_v2 -

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:totolink:ex300_v2_firmware:4.0.3c.7484:*:*:*:*:*:*:*",
              "matchCriteriaId": "803527FC-A921-40EB-BE58-2AAE37BEA697",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:totolink:ex300_v2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2C7D15BE-D0FA-48C4-9752-F11255ABA2BA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "TOTOLINK EX300_V2 V4.0.3c.7484 was discovered to contain a command injection vulnerability via the langType parameter in the setLanguageCfg function. This vulnerability is exploitable via a crafted MQTT data packet."
    },
    {
      "lang": "es",
      "value": "Se ha detectado que TOTOLINK EX300_V2 versi\u00f3n V4.0.3c.7484, contiene una vulnerabilidad de inyecci\u00f3n de comandos por medio del par\u00e1metro langType en la funci\u00f3n setLanguageCfg. Esta vulnerabilidad es explotable por medio de un paquete de datos MQTT dise\u00f1ado"
    }
  ],
  "id": "CVE-2022-32449",
  "lastModified": "2024-11-21T07:06:22.550",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 10.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-07-07T19:15:08.350",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/winmt/CVE/blob/main/TOTOLINK%20EX300_V2/README.md"
    },
    {
      "source": "cve@mitre.org",
      "url": "https://github.com/winmt/my-vuls/tree/main/TOTOLINK%20EX300_V2"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/winmt/CVE/blob/main/TOTOLINK%20EX300_V2/README.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://github.com/winmt/my-vuls/tree/main/TOTOLINK%20EX300_V2"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-77"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2021-43663

Vulnerability from fkie_nvd - Published: 2022-03-31 00:15 - Updated: 2024-11-21 06:29
Summary
totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a command injection vulnerability via the component cloudupdate_check.
Impacted products
Vendor Product Version
totolink ex300_v2_firmware 4.0.3c.140_b20210429
totolink ex300_v2 -

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:totolink:ex300_v2_firmware:4.0.3c.140_b20210429:*:*:*:*:*:*:*",
              "matchCriteriaId": "BD7185B4-C0DA-4EC1-B32E-6D4385A28BA4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:totolink:ex300_v2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2C7D15BE-D0FA-48C4-9752-F11255ABA2BA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a command injection vulnerability via the component cloudupdate_check."
    },
    {
      "lang": "es",
      "value": "Se ha detectado que totolink EX300_v2 versi\u00f3n V4.0.3c.140_B20210429, contiene una vulnerabilidad de inyecci\u00f3n de comandos por medio del componente cloudupdate_check"
    }
  ],
  "id": "CVE-2021-43663",
  "lastModified": "2024-11-21T06:29:34.317",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "ADJACENT_NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 7.9,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:A/AC:M/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 5.5,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.6,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-03-31T00:15:08.033",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/command-injection1.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/command-injection1.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-77"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2021-43661

Vulnerability from fkie_nvd - Published: 2022-03-31 00:15 - Updated: 2024-11-21 06:29
Summary
totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a reflected cross-site scripting (XSS) vulnerability via the component /home.asp.
Impacted products
Vendor Product Version
totolink ex300_v2_firmware 4.0.3c.140_b20210429
totolink ex300_v2 -

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:totolink:ex300_v2_firmware:4.0.3c.140_b20210429:*:*:*:*:*:*:*",
              "matchCriteriaId": "BD7185B4-C0DA-4EC1-B32E-6D4385A28BA4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:totolink:ex300_v2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2C7D15BE-D0FA-48C4-9752-F11255ABA2BA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a reflected cross-site scripting (XSS) vulnerability via the component /home.asp."
    },
    {
      "lang": "es",
      "value": "Se ha detectado que totolink EX300_v2 versi\u00f3n V4.0.3c.140_B20210429, contiene una vulnerabilidad de tipo cross-site scripting (XSS) reflejada por medio del componente /home.asp"
    }
  ],
  "id": "CVE-2021-43661",
  "lastModified": "2024-11-21T06:29:34.000",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 4.3,
          "confidentialityImpact": "NONE",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 6.1,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 2.7,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-03-31T00:15:07.947",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/xss-vulnerability.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/xss-vulnerability.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2021-43662

Vulnerability from fkie_nvd - Published: 2022-03-31 00:15 - Updated: 2024-11-21 06:29
Summary
totolink EX300_v2, ver V4.0.3c.140_B20210429 and A720R ,ver V4.1.5cu.470_B20200911 have an issue which causes uncontrolled resource consumption.
Impacted products
Vendor Product Version
totolink ex300_v2_firmware 4.0.3c.140_b20210429
totolink ex300_v2 -
totolink a720r_firmware 4.1.5cu.470_b20200911
totolink a720r -

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:totolink:ex300_v2_firmware:4.0.3c.140_b20210429:*:*:*:*:*:*:*",
              "matchCriteriaId": "BD7185B4-C0DA-4EC1-B32E-6D4385A28BA4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:totolink:ex300_v2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2C7D15BE-D0FA-48C4-9752-F11255ABA2BA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:totolink:a720r_firmware:4.1.5cu.470_b20200911:*:*:*:*:*:*:*",
              "matchCriteriaId": "C7B3C9D3-E762-4AEE-9E03-B2A1819785A4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:totolink:a720r:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A1DE5168-B787-462C-B024-2B8F73759034",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "totolink EX300_v2, ver V4.0.3c.140_B20210429 and A720R ,ver V4.1.5cu.470_B20200911 have an issue which causes uncontrolled resource consumption."
    },
    {
      "lang": "es",
      "value": "totolink EX300_v2, versi\u00f3n V4.0.3c.140_B20210429 y A720R ,versi\u00f3n V4.1.5cu.470_B20200911, presentan un problema que causa un consumo no controlado de recursos"
    }
  ],
  "id": "CVE-2021-43662",
  "lastModified": "2024-11-21T06:29:34.157",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "LOW",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "ADJACENT_NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 3.3,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 6.5,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-03-31T00:15:07.987",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/dos.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/dos.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-770"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2022-25008

Vulnerability from fkie_nvd - Published: 2022-03-30 23:15 - Updated: 2024-11-21 06:51
Summary
totolink EX300_v2 V4.0.3c.140_B20210429 and EX1200T V4.1.2cu.5230_B20210706 does not contain an authentication mechanism.
Impacted products
Vendor Product Version
totolink ex300_v2_firmware 4.0.3c.140_b20210429
totolink ex300_v2 -
totolink ex1200t_firmware 4.1.2cu.5230_b20210706
totolink ex1200t -

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:totolink:ex300_v2_firmware:4.0.3c.140_b20210429:*:*:*:*:*:*:*",
              "matchCriteriaId": "BD7185B4-C0DA-4EC1-B32E-6D4385A28BA4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:totolink:ex300_v2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2C7D15BE-D0FA-48C4-9752-F11255ABA2BA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:totolink:ex1200t_firmware:4.1.2cu.5230_b20210706:*:*:*:*:*:*:*",
              "matchCriteriaId": "B0FD1F54-D54F-4038-AA4E-09F203FA7396",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:totolink:ex1200t:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F262644E-2558-423E-A19E-7C86A1756FBF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "totolink EX300_v2 V4.0.3c.140_B20210429 and EX1200T V4.1.2cu.5230_B20210706 does not contain an authentication mechanism."
    },
    {
      "lang": "es",
      "value": "Totolink EX300_v2 versi\u00f3n V4.0.3c.140_B20210429 y EX1200T versi\u00f3n V4.1.2cu.5230_B20210706, no contienen un mecanismo de autenticaci\u00f3n"
    }
  ],
  "id": "CVE-2022-25008",
  "lastModified": "2024-11-21T06:51:32.073",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "ADJACENT_NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 5.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 6.5,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-03-30T23:15:08.093",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/missing-authentication.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/missing-authentication.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-306"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2021-43664

Vulnerability from fkie_nvd - Published: 2022-03-30 23:15 - Updated: 2024-11-21 06:29
Summary
totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a command injection vulnerability via the component process forceugpo.
Impacted products
Vendor Product Version
totolink ex300_v2_firmware 4.0.3c.140_b20210429
totolink ex300_v2 -

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:totolink:ex300_v2_firmware:4.0.3c.140_b20210429:*:*:*:*:*:*:*",
              "matchCriteriaId": "BD7185B4-C0DA-4EC1-B32E-6D4385A28BA4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:totolink:ex300_v2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2C7D15BE-D0FA-48C4-9752-F11255ABA2BA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a command injection vulnerability via the component process\u0026nbsp;forceugpo."
    },
    {
      "lang": "es",
      "value": "Se ha detectado que totolink EX300_v2 versi\u00f3n V4.0.3c.140_B20210429, contiene una vulnerabilidad de inyecci\u00f3n de comandos por medio del componente process\u0026#xa0;forceugpo"
    }
  ],
  "id": "CVE-2021-43664",
  "lastModified": "2024-11-21T06:29:34.470",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 9.3,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.1,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.2,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-03-30T23:15:07.737",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/command-injection2.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/command-injection2.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-77"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

CVE-2022-32449 (GCVE-0-2022-32449)

Vulnerability from cvelistv5 – Published: 2022-07-07 00:00 – Updated: 2024-08-03 07:39
VLAI?
Summary
TOTOLINK EX300_V2 V4.0.3c.7484 was discovered to contain a command injection vulnerability via the langType parameter in the setLanguageCfg function. This vulnerability is exploitable via a crafted MQTT data packet.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T07:39:51.043Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/winmt/CVE/blob/main/TOTOLINK%20EX300_V2/README.md"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/winmt/my-vuls/tree/main/TOTOLINK%20EX300_V2"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "TOTOLINK EX300_V2 V4.0.3c.7484 was discovered to contain a command injection vulnerability via the langType parameter in the setLanguageCfg function. This vulnerability is exploitable via a crafted MQTT data packet."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-01T00:00:00",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/winmt/CVE/blob/main/TOTOLINK%20EX300_V2/README.md"
        },
        {
          "url": "https://github.com/winmt/my-vuls/tree/main/TOTOLINK%20EX300_V2"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-32449",
    "datePublished": "2022-07-07T00:00:00",
    "dateReserved": "2022-06-05T00:00:00",
    "dateUpdated": "2024-08-03T07:39:51.043Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-43663 (GCVE-0-2021-43663)

Vulnerability from cvelistv5 – Published: 2022-03-30 23:40 – Updated: 2024-08-04 04:03
VLAI?
Summary
totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a command injection vulnerability via the component cloudupdate_check.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:03:08.611Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/command-injection1.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a command injection vulnerability via the component cloudupdate_check."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-30T23:40:13",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/command-injection1.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-43663",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a command injection vulnerability via the component cloudupdate_check."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/command-injection1.md",
              "refsource": "MISC",
              "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/command-injection1.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-43663",
    "datePublished": "2022-03-30T23:40:13",
    "dateReserved": "2021-11-15T00:00:00",
    "dateUpdated": "2024-08-04T04:03:08.611Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-43662 (GCVE-0-2021-43662)

Vulnerability from cvelistv5 – Published: 2022-03-30 23:26 – Updated: 2024-08-04 04:03
VLAI?
Summary
totolink EX300_v2, ver V4.0.3c.140_B20210429 and A720R ,ver V4.1.5cu.470_B20200911 have an issue which causes uncontrolled resource consumption.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:03:08.137Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/dos.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "totolink EX300_v2, ver V4.0.3c.140_B20210429 and A720R ,ver V4.1.5cu.470_B20200911 have an issue which causes uncontrolled resource consumption."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-30T23:26:03",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/dos.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-43662",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "totolink EX300_v2, ver V4.0.3c.140_B20210429 and A720R ,ver V4.1.5cu.470_B20200911 have an issue which causes uncontrolled resource consumption."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/dos.md",
              "refsource": "MISC",
              "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/dos.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-43662",
    "datePublished": "2022-03-30T23:26:03",
    "dateReserved": "2021-11-15T00:00:00",
    "dateUpdated": "2024-08-04T04:03:08.137Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-43661 (GCVE-0-2021-43661)

Vulnerability from cvelistv5 – Published: 2022-03-30 23:19 – Updated: 2024-08-04 04:03
VLAI?
Summary
totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a reflected cross-site scripting (XSS) vulnerability via the component /home.asp.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:03:08.303Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/xss-vulnerability.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a reflected cross-site scripting (XSS) vulnerability via the component /home.asp."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-30T23:19:19",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/xss-vulnerability.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-43661",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a reflected cross-site scripting (XSS) vulnerability via the component /home.asp."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/xss-vulnerability.md",
              "refsource": "MISC",
              "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/xss-vulnerability.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-43661",
    "datePublished": "2022-03-30T23:19:19",
    "dateReserved": "2021-11-15T00:00:00",
    "dateUpdated": "2024-08-04T04:03:08.303Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-43664 (GCVE-0-2021-43664)

Vulnerability from cvelistv5 – Published: 2022-03-30 22:53 – Updated: 2024-08-04 04:03
VLAI?
Summary
totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a command injection vulnerability via the component process forceugpo.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:03:08.641Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/command-injection2.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a command injection vulnerability via the component process\u0026nbsp;forceugpo."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-30T22:53:59",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/command-injection2.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-43664",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a command injection vulnerability via the component process\u0026nbsp;forceugpo."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/command-injection2.md",
              "refsource": "MISC",
              "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/command-injection2.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-43664",
    "datePublished": "2022-03-30T22:53:59",
    "dateReserved": "2021-11-15T00:00:00",
    "dateUpdated": "2024-08-04T04:03:08.641Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-25008 (GCVE-0-2022-25008)

Vulnerability from cvelistv5 – Published: 2022-03-30 22:27 – Updated: 2024-08-03 04:29
VLAI?
Summary
totolink EX300_v2 V4.0.3c.140_B20210429 and EX1200T V4.1.2cu.5230_B20210706 does not contain an authentication mechanism.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:29:01.604Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/missing-authentication.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "totolink EX300_v2 V4.0.3c.140_B20210429 and EX1200T V4.1.2cu.5230_B20210706 does not contain an authentication mechanism."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-30T22:27:00",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/missing-authentication.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-25008",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "totolink EX300_v2 V4.0.3c.140_B20210429 and EX1200T V4.1.2cu.5230_B20210706 does not contain an authentication mechanism."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/missing-authentication.md",
              "refsource": "MISC",
              "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/missing-authentication.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-25008",
    "datePublished": "2022-03-30T22:27:00",
    "dateReserved": "2022-02-14T00:00:00",
    "dateUpdated": "2024-08-03T04:29:01.604Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-32449 (GCVE-0-2022-32449)

Vulnerability from nvd – Published: 2022-07-07 00:00 – Updated: 2024-08-03 07:39
VLAI?
Summary
TOTOLINK EX300_V2 V4.0.3c.7484 was discovered to contain a command injection vulnerability via the langType parameter in the setLanguageCfg function. This vulnerability is exploitable via a crafted MQTT data packet.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T07:39:51.043Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/winmt/CVE/blob/main/TOTOLINK%20EX300_V2/README.md"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/winmt/my-vuls/tree/main/TOTOLINK%20EX300_V2"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "TOTOLINK EX300_V2 V4.0.3c.7484 was discovered to contain a command injection vulnerability via the langType parameter in the setLanguageCfg function. This vulnerability is exploitable via a crafted MQTT data packet."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-01T00:00:00",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/winmt/CVE/blob/main/TOTOLINK%20EX300_V2/README.md"
        },
        {
          "url": "https://github.com/winmt/my-vuls/tree/main/TOTOLINK%20EX300_V2"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-32449",
    "datePublished": "2022-07-07T00:00:00",
    "dateReserved": "2022-06-05T00:00:00",
    "dateUpdated": "2024-08-03T07:39:51.043Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-43663 (GCVE-0-2021-43663)

Vulnerability from nvd – Published: 2022-03-30 23:40 – Updated: 2024-08-04 04:03
VLAI?
Summary
totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a command injection vulnerability via the component cloudupdate_check.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:03:08.611Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/command-injection1.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a command injection vulnerability via the component cloudupdate_check."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-30T23:40:13",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/command-injection1.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-43663",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a command injection vulnerability via the component cloudupdate_check."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/command-injection1.md",
              "refsource": "MISC",
              "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/command-injection1.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-43663",
    "datePublished": "2022-03-30T23:40:13",
    "dateReserved": "2021-11-15T00:00:00",
    "dateUpdated": "2024-08-04T04:03:08.611Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-43662 (GCVE-0-2021-43662)

Vulnerability from nvd – Published: 2022-03-30 23:26 – Updated: 2024-08-04 04:03
VLAI?
Summary
totolink EX300_v2, ver V4.0.3c.140_B20210429 and A720R ,ver V4.1.5cu.470_B20200911 have an issue which causes uncontrolled resource consumption.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:03:08.137Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/dos.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "totolink EX300_v2, ver V4.0.3c.140_B20210429 and A720R ,ver V4.1.5cu.470_B20200911 have an issue which causes uncontrolled resource consumption."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-30T23:26:03",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/dos.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-43662",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "totolink EX300_v2, ver V4.0.3c.140_B20210429 and A720R ,ver V4.1.5cu.470_B20200911 have an issue which causes uncontrolled resource consumption."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/dos.md",
              "refsource": "MISC",
              "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/dos.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-43662",
    "datePublished": "2022-03-30T23:26:03",
    "dateReserved": "2021-11-15T00:00:00",
    "dateUpdated": "2024-08-04T04:03:08.137Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-43661 (GCVE-0-2021-43661)

Vulnerability from nvd – Published: 2022-03-30 23:19 – Updated: 2024-08-04 04:03
VLAI?
Summary
totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a reflected cross-site scripting (XSS) vulnerability via the component /home.asp.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:03:08.303Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/xss-vulnerability.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a reflected cross-site scripting (XSS) vulnerability via the component /home.asp."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-30T23:19:19",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/xss-vulnerability.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-43661",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a reflected cross-site scripting (XSS) vulnerability via the component /home.asp."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/xss-vulnerability.md",
              "refsource": "MISC",
              "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/xss-vulnerability.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-43661",
    "datePublished": "2022-03-30T23:19:19",
    "dateReserved": "2021-11-15T00:00:00",
    "dateUpdated": "2024-08-04T04:03:08.303Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-43664 (GCVE-0-2021-43664)

Vulnerability from nvd – Published: 2022-03-30 22:53 – Updated: 2024-08-04 04:03
VLAI?
Summary
totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a command injection vulnerability via the component process forceugpo.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:03:08.641Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/command-injection2.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a command injection vulnerability via the component process\u0026nbsp;forceugpo."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-30T22:53:59",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/command-injection2.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-43664",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "totolink EX300_v2 V4.0.3c.140_B20210429 was discovered to contain a command injection vulnerability via the component process\u0026nbsp;forceugpo."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/command-injection2.md",
              "refsource": "MISC",
              "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/command-injection2.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-43664",
    "datePublished": "2022-03-30T22:53:59",
    "dateReserved": "2021-11-15T00:00:00",
    "dateUpdated": "2024-08-04T04:03:08.641Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-25008 (GCVE-0-2022-25008)

Vulnerability from nvd – Published: 2022-03-30 22:27 – Updated: 2024-08-03 04:29
VLAI?
Summary
totolink EX300_v2 V4.0.3c.140_B20210429 and EX1200T V4.1.2cu.5230_B20210706 does not contain an authentication mechanism.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:29:01.604Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/missing-authentication.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "totolink EX300_v2 V4.0.3c.140_B20210429 and EX1200T V4.1.2cu.5230_B20210706 does not contain an authentication mechanism."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-30T22:27:00",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/missing-authentication.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-25008",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "totolink EX300_v2 V4.0.3c.140_B20210429 and EX1200T V4.1.2cu.5230_B20210706 does not contain an authentication mechanism."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/missing-authentication.md",
              "refsource": "MISC",
              "url": "https://github.com/chibataiki/iot-vuls/blob/main/totolink/missing-authentication.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-25008",
    "datePublished": "2022-03-30T22:27:00",
    "dateReserved": "2022-02-14T00:00:00",
    "dateUpdated": "2024-08-03T04:29:01.604Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}