FKIE_CVE-2019-7666
Vulnerability from fkie_nvd - Published: 2019-07-01 19:15 - Updated: 2024-11-21 04:48
Severity ?
Summary
Prima Systems FlexAir, Versions 2.3.38 and prior. The application allows improper authentication using the MD5 hash value of the password, which may allow an attacker with access to the database to login as admin without decrypting the password.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | http://packetstormsecurity.com/files/155262/Prima-FlexAir-Access-Control-2.3.35-Database-Backup-Predictable-Name.html | Exploit, Third Party Advisory, VDB Entry | |
| cve@mitre.org | https://applied-risk.com/labs/advisories | Third Party Advisory | |
| cve@mitre.org | https://www.applied-risk.com/resources/ar-2019-007 | Third Party Advisory | |
| cve@mitre.org | https://www.us-cert.gov/ics/advisories/icsa-19-211-02 | Third Party Advisory, US Government Resource | |
| af854a3a-2127-422b-91ae-364da2661108 | http://packetstormsecurity.com/files/155262/Prima-FlexAir-Access-Control-2.3.35-Database-Backup-Predictable-Name.html | Exploit, Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://applied-risk.com/labs/advisories | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.applied-risk.com/resources/ar-2019-007 | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.us-cert.gov/ics/advisories/icsa-19-211-02 | Third Party Advisory, US Government Resource |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| primasystems | flexair | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:primasystems:flexair:*:*:*:*:*:*:*:*",
"matchCriteriaId": "175CBF56-BD66-48B3-A3AC-25B4FCD4F601",
"versionEndIncluding": "2.3.38",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Prima Systems FlexAir, Versions 2.3.38 and prior. The application allows improper authentication using the MD5 hash value of the password, which may allow an attacker with access to the database to login as admin without decrypting the password."
},
{
"lang": "es",
"value": "Prima Systems FlexAir, versiones 2.3.38 y anteriores. La aplicaci\u00f3n permite una autenticaci\u00f3n incorrecta utilizando el valor hash MD5 de la contrase\u00f1a, lo que puede permitir que un atacante con acceso a la base de datos inicie sesi\u00f3n como administrador sin descifrar la contrase\u00f1a."
}
],
"id": "CVE-2019-7666",
"lastModified": "2024-11-21T04:48:29.777",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "PARTIAL",
"baseScore": 6.5,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2019-07-01T19:15:11.477",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory",
"VDB Entry"
],
"url": "http://packetstormsecurity.com/files/155262/Prima-FlexAir-Access-Control-2.3.35-Database-Backup-Predictable-Name.html"
},
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
],
"url": "https://www.applied-risk.com/resources/ar-2019-007"
},
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory",
"VDB Entry"
],
"url": "http://packetstormsecurity.com/files/155262/Prima-FlexAir-Access-Control-2.3.35-Database-Backup-Predictable-Name.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://www.applied-risk.com/resources/ar-2019-007"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-287"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2019-7669
Vulnerability from fkie_nvd - Published: 2019-07-01 19:15 - Updated: 2024-11-21 04:48
Severity ?
Summary
Prima Systems FlexAir, Versions 2.3.38 and prior. Improper validation of file extensions when uploading files could allow a remote authenticated attacker to upload and execute malicious applications within the application’s web root with root privileges.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | http://packetstormsecurity.com/files/155270/FlexAir-Access-Control-2.3.38-Command-Injection.html | Exploit, Third Party Advisory, VDB Entry | |
| cve@mitre.org | https://applied-risk.com/labs/advisories | Third Party Advisory | |
| cve@mitre.org | https://www.applied-risk.com/resources/ar-2019-007 | Third Party Advisory | |
| cve@mitre.org | https://www.us-cert.gov/ics/advisories/icsa-19-211-02 | Third Party Advisory, US Government Resource | |
| af854a3a-2127-422b-91ae-364da2661108 | http://packetstormsecurity.com/files/155270/FlexAir-Access-Control-2.3.38-Command-Injection.html | Exploit, Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://applied-risk.com/labs/advisories | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.applied-risk.com/resources/ar-2019-007 | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.us-cert.gov/ics/advisories/icsa-19-211-02 | Third Party Advisory, US Government Resource |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| primasystems | flexair | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:primasystems:flexair:*:*:*:*:*:*:*:*",
"matchCriteriaId": "175CBF56-BD66-48B3-A3AC-25B4FCD4F601",
"versionEndIncluding": "2.3.38",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Prima Systems FlexAir, Versions 2.3.38 and prior. Improper validation of file extensions when uploading files could allow a remote authenticated attacker to upload and execute malicious applications within the application\u2019s web root with root privileges."
},
{
"lang": "es",
"value": "Prima Systems FlexAir, versiones 2.3.38 y anteriores. La validaci\u00f3n incorrecta de las extensiones de archivo al cargar archivos podr\u00eda permitir que un atacante autenticado remoto cargue y ejecute aplicaciones maliciosas dentro de la ra\u00edz web de la aplicaci\u00f3n con privilegios de root."
}
],
"id": "CVE-2019-7669",
"lastModified": "2024-11-21T04:48:30.223",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2019-07-01T19:15:11.697",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory",
"VDB Entry"
],
"url": "http://packetstormsecurity.com/files/155270/FlexAir-Access-Control-2.3.38-Command-Injection.html"
},
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
],
"url": "https://www.applied-risk.com/resources/ar-2019-007"
},
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory",
"VDB Entry"
],
"url": "http://packetstormsecurity.com/files/155270/FlexAir-Access-Control-2.3.38-Command-Injection.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://www.applied-risk.com/resources/ar-2019-007"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-434"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2019-7668
Vulnerability from fkie_nvd - Published: 2019-07-01 19:15 - Updated: 2024-11-21 04:48
Severity ?
Summary
Prima Systems FlexAir devices have Default Credentials.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://applied-risk.com/labs/advisories | Third Party Advisory | |
| cve@mitre.org | https://www.applied-risk.com/resources/ar-2019-007 | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://applied-risk.com/labs/advisories | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.applied-risk.com/resources/ar-2019-007 | Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| primasystems | flexair | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:primasystems:flexair:*:*:*:*:*:*:*:*",
"matchCriteriaId": "175CBF56-BD66-48B3-A3AC-25B4FCD4F601",
"versionEndIncluding": "2.3.38",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Prima Systems FlexAir devices have Default Credentials."
},
{
"lang": "es",
"value": "Los dispositivos Prima Systems FlexAir tienen credenciales predeterminadas."
}
],
"id": "CVE-2019-7668",
"lastModified": "2024-11-21T04:48:30.083",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2019-07-01T19:15:11.633",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
],
"url": "https://www.applied-risk.com/resources/ar-2019-007"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://www.applied-risk.com/resources/ar-2019-007"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-1188"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2019-7281
Vulnerability from fkie_nvd - Published: 2019-07-01 19:15 - Updated: 2024-11-21 04:47
Severity ?
Summary
Prima Systems FlexAir, Versions 2.3.38 and prior. An unauthenticated user can send unverified HTTP requests, which may allow the attacker to perform certain actions with administrative privileges if a logged-in user visits a malicious website.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://applied-risk.com/labs/advisories | Not Applicable, Third Party Advisory | |
| cve@mitre.org | https://www.applied-risk.com/resources/ar-2019-007 | Third Party Advisory | |
| cve@mitre.org | https://www.us-cert.gov/ics/advisories/icsa-19-211-02 | Third Party Advisory, US Government Resource | |
| af854a3a-2127-422b-91ae-364da2661108 | https://applied-risk.com/labs/advisories | Not Applicable, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.applied-risk.com/resources/ar-2019-007 | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.us-cert.gov/ics/advisories/icsa-19-211-02 | Third Party Advisory, US Government Resource |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| primasystems | flexair | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:primasystems:flexair:*:*:*:*:*:*:*:*",
"matchCriteriaId": "175CBF56-BD66-48B3-A3AC-25B4FCD4F601",
"versionEndIncluding": "2.3.38",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Prima Systems FlexAir, Versions 2.3.38 and prior. An unauthenticated user can send unverified HTTP requests, which may allow the attacker to perform certain actions with administrative privileges if a logged-in user visits a malicious website."
},
{
"lang": "es",
"value": "Prima Systems FlexAir, en la versi\u00f3n 2.3.38 y anteriores. Un usuario no autenticado puede enviar solicitudes HTTP no verificadas, lo que puede permitir al atacante realizar ciertas acciones con privilegios administrativos si un usuario conectado visita un sitio web malicioso."
}
],
"id": "CVE-2019-7281",
"lastModified": "2024-11-21T04:47:55.067",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2019-07-01T19:15:11.383",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Not Applicable",
"Third Party Advisory"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
],
"url": "https://www.applied-risk.com/resources/ar-2019-007"
},
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Not Applicable",
"Third Party Advisory"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://www.applied-risk.com/resources/ar-2019-007"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-352"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2019-7667
Vulnerability from fkie_nvd - Published: 2019-07-01 19:15 - Updated: 2024-11-21 04:48
Severity ?
Summary
Prima Systems FlexAir, Versions 2.3.38 and prior. The application generates database backup files with a predictable name, and an attacker can use brute force to identify the database backup file name. A malicious actor can exploit this issue to download the database file and disclose login information, which can allow the attacker to bypass authentication and have full access to the system.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | http://packetstormsecurity.com/files/155262/Prima-FlexAir-Access-Control-2.3.35-Database-Backup-Predictable-Name.html | Exploit, Third Party Advisory, VDB Entry | |
| cve@mitre.org | https://applied-risk.com/labs/advisories | Third Party Advisory | |
| cve@mitre.org | https://www.applied-risk.com/resources/ar-2019-007 | Third Party Advisory | |
| cve@mitre.org | https://www.us-cert.gov/ics/advisories/icsa-19-211-02 | Third Party Advisory, US Government Resource | |
| af854a3a-2127-422b-91ae-364da2661108 | http://packetstormsecurity.com/files/155262/Prima-FlexAir-Access-Control-2.3.35-Database-Backup-Predictable-Name.html | Exploit, Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://applied-risk.com/labs/advisories | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.applied-risk.com/resources/ar-2019-007 | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.us-cert.gov/ics/advisories/icsa-19-211-02 | Third Party Advisory, US Government Resource |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| primasystems | flexair | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:primasystems:flexair:*:*:*:*:*:*:*:*",
"matchCriteriaId": "175CBF56-BD66-48B3-A3AC-25B4FCD4F601",
"versionEndIncluding": "2.3.38",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Prima Systems FlexAir, Versions 2.3.38 and prior. The application generates database backup files with a predictable name, and an attacker can use brute force to identify the database backup file name. A malicious actor can exploit this issue to download the database file and disclose login information, which can allow the attacker to bypass authentication and have full access to the system."
},
{
"lang": "es",
"value": "Prima Systems FlexAir, en la version 2.3.38 y anteriores. La aplicaci\u00f3n genera archivos de respaldo de la base de datos con un nombre predecible, y un atacante puede forzar para identificar el nombre del archivo de respaldo de la base de datos. Un actor malintencionado puede explotar este problema para descargar el archivo de la base de datos y divulgar informaci\u00f3n de inicio de sesi\u00f3n, lo que puede permitir al atacante omitir la autenticaci\u00f3n y tener acceso completo al sistema."
}
],
"id": "CVE-2019-7667",
"lastModified": "2024-11-21T04:48:29.923",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 6.4,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 4.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2019-07-01T19:15:11.570",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory",
"VDB Entry"
],
"url": "http://packetstormsecurity.com/files/155262/Prima-FlexAir-Access-Control-2.3.35-Database-Backup-Predictable-Name.html"
},
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
],
"url": "https://www.applied-risk.com/resources/ar-2019-007"
},
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory",
"VDB Entry"
],
"url": "http://packetstormsecurity.com/files/155262/Prima-FlexAir-Access-Control-2.3.35-Database-Backup-Predictable-Name.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://www.applied-risk.com/resources/ar-2019-007"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-330"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2019-7670
Vulnerability from fkie_nvd - Published: 2019-07-01 19:15 - Updated: 2024-11-21 04:48
Severity ?
Summary
Prima Systems FlexAir, Versions 2.3.38 and prior. The application incorrectly neutralizes special elements that could modify the intended OS command when it is sent to a downstream component, which could allow attackers to execute commands directly on the operating system.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | http://packetstormsecurity.com/files/155271/FlexAir-Access-Control-2.3.38-Remote-Root.html | Exploit, Third Party Advisory, VDB Entry | |
| cve@mitre.org | https://applied-risk.com/labs/advisories | Third Party Advisory | |
| cve@mitre.org | https://www.us-cert.gov/ics/advisories/icsa-19-211-02 | Third Party Advisory, US Government Resource | |
| nvd@nist.gov | https://www.applied-risk.com/resources/ar-2019-007 | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | http://packetstormsecurity.com/files/155271/FlexAir-Access-Control-2.3.38-Remote-Root.html | Exploit, Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://applied-risk.com/labs/advisories | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.us-cert.gov/ics/advisories/icsa-19-211-02 | Third Party Advisory, US Government Resource |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| primasystems | flexair | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:primasystems:flexair:*:*:*:*:*:*:*:*",
"matchCriteriaId": "175CBF56-BD66-48B3-A3AC-25B4FCD4F601",
"versionEndIncluding": "2.3.38",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Prima Systems FlexAir, Versions 2.3.38 and prior. The application incorrectly neutralizes special elements that could modify the intended OS command when it is sent to a downstream component, which could allow attackers to execute commands directly on the operating system."
},
{
"lang": "es",
"value": "Los dispositivos Prima Systems FlexAir, versiones 2.3.38 y anteriores. La aplicaci\u00f3n neutraliza incorrectamente elementos especiales que podr\u00edan modificar el comando del sistema operativo deseado cuando se env\u00eda a un componente posterior, lo que podr\u00eda permitir a los atacantes ejecutar comandos directamente en el sistema operativo."
}
],
"id": "CVE-2019-7670",
"lastModified": "2024-11-21T04:48:30.383",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.2,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2019-07-01T19:15:11.790",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory",
"VDB Entry"
],
"url": "http://packetstormsecurity.com/files/155271/FlexAir-Access-Control-2.3.38-Remote-Root.html"
},
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
},
{
"source": "nvd@nist.gov",
"tags": [
"Third Party Advisory"
],
"url": "https://www.applied-risk.com/resources/ar-2019-007"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory",
"VDB Entry"
],
"url": "http://packetstormsecurity.com/files/155271/FlexAir-Access-Control-2.3.38-Remote-Root.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-78"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2019-7280
Vulnerability from fkie_nvd - Published: 2019-07-01 19:15 - Updated: 2024-11-21 04:47
Severity ?
Summary
Prima Systems FlexAir, Versions 2.3.38 and prior. The session-ID is of an insufficient length and can be exploited by brute force, which may allow a remote attacker to obtain a valid session and bypass authentication.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://applied-risk.com/labs/advisories | Not Applicable, Third Party Advisory | |
| cve@mitre.org | https://www.applied-risk.com/resources/ar-2019-007 | Third Party Advisory | |
| cve@mitre.org | https://www.us-cert.gov/ics/advisories/icsa-19-211-02 | Third Party Advisory, US Government Resource | |
| af854a3a-2127-422b-91ae-364da2661108 | https://applied-risk.com/labs/advisories | Not Applicable, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.applied-risk.com/resources/ar-2019-007 | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.us-cert.gov/ics/advisories/icsa-19-211-02 | Third Party Advisory, US Government Resource |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| primasystems | flexair | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:primasystems:flexair:*:*:*:*:*:*:*:*",
"matchCriteriaId": "175CBF56-BD66-48B3-A3AC-25B4FCD4F601",
"versionEndIncluding": "2.3.38",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Prima Systems FlexAir, Versions 2.3.38 and prior. The session-ID is of an insufficient length and can be exploited by brute force, which may allow a remote attacker to obtain a valid session and bypass authentication."
},
{
"lang": "es",
"value": "Prima Systems FlexAir, versiones 2.3.38 y anteriores. El ID de sesi\u00f3n tiene una longitud insuficiente y puede ser explotado por la fuerza bruta, lo que puede permitir que un atacante remoto obtenga una sesi\u00f3n v\u00e1lida y omita la autenticaci\u00f3n."
}
],
"id": "CVE-2019-7280",
"lastModified": "2024-11-21T04:47:54.910",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "NONE",
"baseScore": 4.0,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2019-07-01T19:15:11.290",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Not Applicable",
"Third Party Advisory"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
],
"url": "https://www.applied-risk.com/resources/ar-2019-007"
},
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Not Applicable",
"Third Party Advisory"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://www.applied-risk.com/resources/ar-2019-007"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-613"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2019-7672
Vulnerability from fkie_nvd - Published: 2019-06-05 19:29 - Updated: 2024-11-21 04:48
Severity ?
Summary
Prima Systems FlexAir, Versions 2.3.38 and prior. The flash version of the web interface contains a hard-coded username and password, which may allow an authenticated attacker to escalate privileges.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://applied-risk.com/index.php/download_file/view/199/165 | Broken Link | |
| cve@mitre.org | https://applied-risk.com/labs/advisories | Third Party Advisory | |
| cve@mitre.org | https://applied-risk.com/resources/ar-2019-007 | Exploit, Third Party Advisory | |
| cve@mitre.org | https://www.us-cert.gov/ics/advisories/icsa-19-211-02 | Third Party Advisory, US Government Resource | |
| af854a3a-2127-422b-91ae-364da2661108 | https://applied-risk.com/index.php/download_file/view/199/165 | Broken Link | |
| af854a3a-2127-422b-91ae-364da2661108 | https://applied-risk.com/labs/advisories | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://applied-risk.com/resources/ar-2019-007 | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.us-cert.gov/ics/advisories/icsa-19-211-02 | Third Party Advisory, US Government Resource |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| primasystems | flexair | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:primasystems:flexair:*:*:*:*:*:*:*:*",
"matchCriteriaId": "175CBF56-BD66-48B3-A3AC-25B4FCD4F601",
"versionEndIncluding": "2.3.38",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Prima Systems FlexAir, Versions 2.3.38 and prior. The flash version of the web interface contains a hard-coded username and password, which may allow an authenticated attacker to escalate privileges."
},
{
"lang": "es",
"value": "Los dispositivos Prima Systems FlexAir, versiones 2.3.38 y anteriores. La versi\u00f3n flash de la interfaz web contiene un nombre de usuario y contrase\u00f1a codificados, lo que puede permitir que un atacante autenticado aumente los privilegios."
}
],
"id": "CVE-2019-7672",
"lastModified": "2024-11-21T04:48:30.697",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "PARTIAL",
"baseScore": 6.5,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2019-06-05T19:29:00.420",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Broken Link"
],
"url": "https://applied-risk.com/index.php/download_file/view/199/165"
},
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://applied-risk.com/resources/ar-2019-007"
},
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Broken Link"
],
"url": "https://applied-risk.com/index.php/download_file/view/199/165"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://applied-risk.com/resources/ar-2019-007"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-798"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2019-7671
Vulnerability from fkie_nvd - Published: 2019-06-05 19:29 - Updated: 2024-11-21 04:48
Severity ?
Summary
Prima Systems FlexAir, Versions 2.3.38 and prior. Parameters sent to scripts are not properly sanitized before being returned to the user, which may allow an attacker to execute arbitrary code in a user’s browser session in context of an affected site.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| primasystems | flexair | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:primasystems:flexair:*:*:*:*:*:*:*:*",
"matchCriteriaId": "175CBF56-BD66-48B3-A3AC-25B4FCD4F601",
"versionEndIncluding": "2.3.38",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Prima Systems FlexAir, Versions 2.3.38 and prior. Parameters sent to scripts are not properly sanitized before being returned to the user, which may allow an attacker to execute arbitrary code in a user\u2019s browser session in context of an affected site."
},
{
"lang": "es",
"value": "Prima Systems FlexAir, versiones 2.3.38 y anteriores. Los par\u00e1metros enviados a los scripts no se desinfectan correctamente antes de devolverse al usuario, lo que puede permitir que un atacante ejecute c\u00f3digo arbitrario en la sesi\u00f3n del navegador de un usuario en el contexto de un sitio afectado."
}
],
"id": "CVE-2019-7671",
"lastModified": "2024-11-21T04:48:30.530",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "LOW",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "NONE",
"baseScore": 3.5,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 6.8,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.0,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.3,
"impactScore": 6.0,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2019-06-05T19:29:00.357",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory",
"VDB Entry"
],
"url": "http://packetstormsecurity.com/files/155274/Prima-Access-Control-2.3.35-Cross-Site-Scripting.html"
},
{
"source": "cve@mitre.org",
"tags": [
"Broken Link"
],
"url": "https://applied-risk.com/index.php/download_file/view/199/165"
},
{
"source": "cve@mitre.org",
"tags": [
"Not Applicable",
"Third Party Advisory"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
],
"url": "https://applied-risk.com/resources/ar-2019-007"
},
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory",
"VDB Entry"
],
"url": "http://packetstormsecurity.com/files/155274/Prima-Access-Control-2.3.35-Cross-Site-Scripting.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Broken Link"
],
"url": "https://applied-risk.com/index.php/download_file/view/199/165"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Not Applicable",
"Third Party Advisory"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://applied-risk.com/resources/ar-2019-007"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2019-9189
Vulnerability from fkie_nvd - Published: 2019-06-05 18:29 - Updated: 2024-11-21 04:51
Severity ?
Summary
Prima Systems FlexAir, Versions 2.4.9api3 and prior. The application allows the upload of arbitrary Python scripts when configuring the main central controller. These scripts can be immediately executed because of root code execution, not as a web server user, allowing an authenticated attacker to gain full system access.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| primasystems | flexair | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:primasystems:flexair:*:*:*:*:*:*:*:*",
"matchCriteriaId": "175CBF56-BD66-48B3-A3AC-25B4FCD4F601",
"versionEndIncluding": "2.3.38",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Prima Systems FlexAir, Versions 2.4.9api3 and prior. The application allows the upload of arbitrary Python scripts when configuring the main central controller. These scripts can be immediately executed because of root code execution, not as a web server user, allowing an authenticated attacker to gain full system access."
},
{
"lang": "es",
"value": "En los dispositivos Prima Systems FlexAir, versiones 2.4.9api3 y anteriores. La aplicaci\u00f3n permite la carga de scripts arbitrarios de Python al configurar el controlador central principal. Estos scripts pueden ejecutarse inmediatamente debido a la ejecuci\u00f3n del c\u00f3digo ra\u00edz, no como un usuario del servidor web, lo que permite que un atacante autenticado obtenga acceso completo al sistema."
}
],
"id": "CVE-2019-9189",
"lastModified": "2024-11-21T04:51:10.250",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2019-06-05T18:29:01.217",
"references": [
{
"source": "cve@mitre.org",
"url": "http://packetstormsecurity.com/files/155273/Prima-Access-Control-2.3.35-Script-Upload-Remote-Code-Execution.html"
},
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
],
"url": "https://applied-risk.com/index.php/download_file/view/199/165"
},
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
],
"url": "https://applied-risk.com/resources/ar-2019-007"
},
{
"source": "cve@mitre.org",
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "http://packetstormsecurity.com/files/155273/Prima-Access-Control-2.3.35-Script-Upload-Remote-Code-Execution.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://applied-risk.com/index.php/download_file/view/199/165"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://applied-risk.com/resources/ar-2019-007"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-434"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
CVE-2019-7280 (GCVE-0-2019-7280)
Vulnerability from cvelistv5 – Published: 2019-07-01 18:31 – Updated: 2024-08-04 20:46
VLAI?
Summary
Prima Systems FlexAir, Versions 2.3.38 and prior. The session-ID is of an insufficient length and can be exploited by brute force, which may allow a remote attacker to obtain a valid session and bypass authentication.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:46:46.112Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.applied-risk.com/resources/ar-2019-007"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Prima Systems FlexAir, Versions 2.3.38 and prior. The session-ID is of an insufficient length and can be exploited by brute force, which may allow a remote attacker to obtain a valid session and bypass authentication."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-07-31T15:03:28",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.applied-risk.com/resources/ar-2019-007"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2019-7280",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Prima Systems FlexAir, Versions 2.3.38 and prior. The session-ID is of an insufficient length and can be exploited by brute force, which may allow a remote attacker to obtain a valid session and bypass authentication."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://applied-risk.com/labs/advisories",
"refsource": "MISC",
"url": "https://applied-risk.com/labs/advisories"
},
{
"name": "https://www.applied-risk.com/resources/ar-2019-007",
"refsource": "MISC",
"url": "https://www.applied-risk.com/resources/ar-2019-007"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-7280",
"datePublished": "2019-07-01T18:31:34",
"dateReserved": "2019-01-31T00:00:00",
"dateUpdated": "2024-08-04T20:46:46.112Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-7281 (GCVE-0-2019-7281)
Vulnerability from cvelistv5 – Published: 2019-07-01 18:29 – Updated: 2024-08-04 20:46
VLAI?
Summary
Prima Systems FlexAir, Versions 2.3.38 and prior. An unauthenticated user can send unverified HTTP requests, which may allow the attacker to perform certain actions with administrative privileges if a logged-in user visits a malicious website.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:46:45.825Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.applied-risk.com/resources/ar-2019-007"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Prima Systems FlexAir, Versions 2.3.38 and prior. An unauthenticated user can send unverified HTTP requests, which may allow the attacker to perform certain actions with administrative privileges if a logged-in user visits a malicious website."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-07-31T14:00:59",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.applied-risk.com/resources/ar-2019-007"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2019-7281",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Prima Systems FlexAir, Versions 2.3.38 and prior. An unauthenticated user can send unverified HTTP requests, which may allow the attacker to perform certain actions with administrative privileges if a logged-in user visits a malicious website."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://applied-risk.com/labs/advisories",
"refsource": "MISC",
"url": "https://applied-risk.com/labs/advisories"
},
{
"name": "https://www.applied-risk.com/resources/ar-2019-007",
"refsource": "MISC",
"url": "https://www.applied-risk.com/resources/ar-2019-007"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-7281",
"datePublished": "2019-07-01T18:29:43",
"dateReserved": "2019-01-31T00:00:00",
"dateUpdated": "2024-08-04T20:46:45.825Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-7666 (GCVE-0-2019-7666)
Vulnerability from cvelistv5 – Published: 2019-07-01 18:27 – Updated: 2024-08-04 20:54
VLAI?
Summary
Prima Systems FlexAir, Versions 2.3.38 and prior. The application allows improper authentication using the MD5 hash value of the password, which may allow an attacker with access to the database to login as admin without decrypting the password.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:54:28.425Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.applied-risk.com/resources/ar-2019-007"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/155262/Prima-FlexAir-Access-Control-2.3.35-Database-Backup-Predictable-Name.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Prima Systems FlexAir, Versions 2.3.38 and prior. The application allows improper authentication using the MD5 hash value of the password, which may allow an attacker with access to the database to login as admin without decrypting the password."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-11-12T20:07:01",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.applied-risk.com/resources/ar-2019-007"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://packetstormsecurity.com/files/155262/Prima-FlexAir-Access-Control-2.3.35-Database-Backup-Predictable-Name.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2019-7666",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Prima Systems FlexAir, Versions 2.3.38 and prior. The application allows improper authentication using the MD5 hash value of the password, which may allow an attacker with access to the database to login as admin without decrypting the password."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://applied-risk.com/labs/advisories",
"refsource": "MISC",
"url": "https://applied-risk.com/labs/advisories"
},
{
"name": "https://www.applied-risk.com/resources/ar-2019-007",
"refsource": "MISC",
"url": "https://www.applied-risk.com/resources/ar-2019-007"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
},
{
"name": "http://packetstormsecurity.com/files/155262/Prima-FlexAir-Access-Control-2.3.35-Database-Backup-Predictable-Name.html",
"refsource": "MISC",
"url": "http://packetstormsecurity.com/files/155262/Prima-FlexAir-Access-Control-2.3.35-Database-Backup-Predictable-Name.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-7666",
"datePublished": "2019-07-01T18:27:36",
"dateReserved": "2019-02-09T00:00:00",
"dateUpdated": "2024-08-04T20:54:28.425Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-7667 (GCVE-0-2019-7667)
Vulnerability from cvelistv5 – Published: 2019-07-01 18:22 – Updated: 2024-08-04 20:54
VLAI?
Summary
Prima Systems FlexAir, Versions 2.3.38 and prior. The application generates database backup files with a predictable name, and an attacker can use brute force to identify the database backup file name. A malicious actor can exploit this issue to download the database file and disclose login information, which can allow the attacker to bypass authentication and have full access to the system.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:54:28.515Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.applied-risk.com/resources/ar-2019-007"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/155262/Prima-FlexAir-Access-Control-2.3.35-Database-Backup-Predictable-Name.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Prima Systems FlexAir, Versions 2.3.38 and prior. The application generates database backup files with a predictable name, and an attacker can use brute force to identify the database backup file name. A malicious actor can exploit this issue to download the database file and disclose login information, which can allow the attacker to bypass authentication and have full access to the system."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-11-12T20:07:01",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.applied-risk.com/resources/ar-2019-007"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://packetstormsecurity.com/files/155262/Prima-FlexAir-Access-Control-2.3.35-Database-Backup-Predictable-Name.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2019-7667",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Prima Systems FlexAir, Versions 2.3.38 and prior. The application generates database backup files with a predictable name, and an attacker can use brute force to identify the database backup file name. A malicious actor can exploit this issue to download the database file and disclose login information, which can allow the attacker to bypass authentication and have full access to the system."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://applied-risk.com/labs/advisories",
"refsource": "MISC",
"url": "https://applied-risk.com/labs/advisories"
},
{
"name": "https://www.applied-risk.com/resources/ar-2019-007",
"refsource": "MISC",
"url": "https://www.applied-risk.com/resources/ar-2019-007"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
},
{
"name": "http://packetstormsecurity.com/files/155262/Prima-FlexAir-Access-Control-2.3.35-Database-Backup-Predictable-Name.html",
"refsource": "MISC",
"url": "http://packetstormsecurity.com/files/155262/Prima-FlexAir-Access-Control-2.3.35-Database-Backup-Predictable-Name.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-7667",
"datePublished": "2019-07-01T18:22:21",
"dateReserved": "2019-02-09T00:00:00",
"dateUpdated": "2024-08-04T20:54:28.515Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-7668 (GCVE-0-2019-7668)
Vulnerability from cvelistv5 – Published: 2019-07-01 18:20 – Updated: 2024-08-04 20:54
VLAI?
Summary
Prima Systems FlexAir devices have Default Credentials.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:54:28.447Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.applied-risk.com/resources/ar-2019-007"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Prima Systems FlexAir devices have Default Credentials."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-07-01T18:20:35",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.applied-risk.com/resources/ar-2019-007"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2019-7668",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Prima Systems FlexAir devices have Default Credentials."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://applied-risk.com/labs/advisories",
"refsource": "MISC",
"url": "https://applied-risk.com/labs/advisories"
},
{
"name": "https://www.applied-risk.com/resources/ar-2019-007",
"refsource": "MISC",
"url": "https://www.applied-risk.com/resources/ar-2019-007"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-7668",
"datePublished": "2019-07-01T18:20:35",
"dateReserved": "2019-02-09T00:00:00",
"dateUpdated": "2024-08-04T20:54:28.447Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-7669 (GCVE-0-2019-7669)
Vulnerability from cvelistv5 – Published: 2019-07-01 18:18 – Updated: 2024-08-04 20:54
VLAI?
Summary
Prima Systems FlexAir, Versions 2.3.38 and prior. Improper validation of file extensions when uploading files could allow a remote authenticated attacker to upload and execute malicious applications within the application’s web root with root privileges.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:54:28.438Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.applied-risk.com/resources/ar-2019-007"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/155270/FlexAir-Access-Control-2.3.38-Command-Injection.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Prima Systems FlexAir, Versions 2.3.38 and prior. Improper validation of file extensions when uploading files could allow a remote authenticated attacker to upload and execute malicious applications within the application\u2019s web root with root privileges."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-11-12T20:07:12",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.applied-risk.com/resources/ar-2019-007"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://packetstormsecurity.com/files/155270/FlexAir-Access-Control-2.3.38-Command-Injection.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2019-7669",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Prima Systems FlexAir, Versions 2.3.38 and prior. Improper validation of file extensions when uploading files could allow a remote authenticated attacker to upload and execute malicious applications within the application\u2019s web root with root privileges."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://applied-risk.com/labs/advisories",
"refsource": "MISC",
"url": "https://applied-risk.com/labs/advisories"
},
{
"name": "https://www.applied-risk.com/resources/ar-2019-007",
"refsource": "MISC",
"url": "https://www.applied-risk.com/resources/ar-2019-007"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
},
{
"name": "http://packetstormsecurity.com/files/155270/FlexAir-Access-Control-2.3.38-Command-Injection.html",
"refsource": "MISC",
"url": "http://packetstormsecurity.com/files/155270/FlexAir-Access-Control-2.3.38-Command-Injection.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-7669",
"datePublished": "2019-07-01T18:18:13",
"dateReserved": "2019-02-09T00:00:00",
"dateUpdated": "2024-08-04T20:54:28.438Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-7670 (GCVE-0-2019-7670)
Vulnerability from cvelistv5 – Published: 2019-07-01 18:12 – Updated: 2024-08-04 20:54
VLAI?
Summary
Prima Systems FlexAir, Versions 2.3.38 and prior. The application incorrectly neutralizes special elements that could modify the intended OS command when it is sent to a downstream component, which could allow attackers to execute commands directly on the operating system.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:54:28.427Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/155271/FlexAir-Access-Control-2.3.38-Remote-Root.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Prima Systems FlexAir, Versions 2.3.38 and prior. The application incorrectly neutralizes special elements that could modify the intended OS command when it is sent to a downstream component, which could allow attackers to execute commands directly on the operating system."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-11-12T20:07:10",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://packetstormsecurity.com/files/155271/FlexAir-Access-Control-2.3.38-Remote-Root.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2019-7670",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Prima Systems FlexAir, Versions 2.3.38 and prior. The application incorrectly neutralizes special elements that could modify the intended OS command when it is sent to a downstream component, which could allow attackers to execute commands directly on the operating system."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://applied-risk.com/labs/advisories",
"refsource": "MISC",
"url": "https://applied-risk.com/labs/advisories"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
},
{
"name": "http://packetstormsecurity.com/files/155271/FlexAir-Access-Control-2.3.38-Remote-Root.html",
"refsource": "MISC",
"url": "http://packetstormsecurity.com/files/155271/FlexAir-Access-Control-2.3.38-Remote-Root.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-7670",
"datePublished": "2019-07-01T18:12:44",
"dateReserved": "2019-02-09T00:00:00",
"dateUpdated": "2024-08-04T20:54:28.427Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-7671 (GCVE-0-2019-7671)
Vulnerability from cvelistv5 – Published: 2019-06-05 18:53 – Updated: 2024-08-04 20:54
VLAI?
Summary
Prima Systems FlexAir, Versions 2.3.38 and prior. Parameters sent to scripts are not properly sanitized before being returned to the user, which may allow an attacker to execute arbitrary code in a user’s browser session in context of an affected site.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:54:28.475Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://applied-risk.com/index.php/download_file/view/199/165"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://applied-risk.com/resources/ar-2019-007"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/155274/Prima-Access-Control-2.3.35-Cross-Site-Scripting.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Prima Systems FlexAir, Versions 2.3.38 and prior. Parameters sent to scripts are not properly sanitized before being returned to the user, which may allow an attacker to execute arbitrary code in a user\u2019s browser session in context of an affected site."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-11-12T20:07:02",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://applied-risk.com/index.php/download_file/view/199/165"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://applied-risk.com/resources/ar-2019-007"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://packetstormsecurity.com/files/155274/Prima-Access-Control-2.3.35-Cross-Site-Scripting.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2019-7671",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Prima Systems FlexAir, Versions 2.3.38 and prior. Parameters sent to scripts are not properly sanitized before being returned to the user, which may allow an attacker to execute arbitrary code in a user\u2019s browser session in context of an affected site."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://applied-risk.com/labs/advisories",
"refsource": "MISC",
"url": "https://applied-risk.com/labs/advisories"
},
{
"name": "https://applied-risk.com/index.php/download_file/view/199/165",
"refsource": "MISC",
"url": "https://applied-risk.com/index.php/download_file/view/199/165"
},
{
"name": "https://applied-risk.com/resources/ar-2019-007",
"refsource": "MISC",
"url": "https://applied-risk.com/resources/ar-2019-007"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
},
{
"name": "http://packetstormsecurity.com/files/155274/Prima-Access-Control-2.3.35-Cross-Site-Scripting.html",
"refsource": "MISC",
"url": "http://packetstormsecurity.com/files/155274/Prima-Access-Control-2.3.35-Cross-Site-Scripting.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-7671",
"datePublished": "2019-06-05T18:53:12",
"dateReserved": "2019-02-09T00:00:00",
"dateUpdated": "2024-08-04T20:54:28.475Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-7672 (GCVE-0-2019-7672)
Vulnerability from cvelistv5 – Published: 2019-06-05 18:49 – Updated: 2024-08-04 20:54
VLAI?
Summary
Prima Systems FlexAir, Versions 2.3.38 and prior. The flash version of the web interface contains a hard-coded username and password, which may allow an authenticated attacker to escalate privileges.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:54:27.995Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://applied-risk.com/index.php/download_file/view/199/165"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://applied-risk.com/resources/ar-2019-007"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Prima Systems FlexAir, Versions 2.3.38 and prior. The flash version of the web interface contains a hard-coded username and password, which may allow an authenticated attacker to escalate privileges."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-07-31T15:06:34",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://applied-risk.com/index.php/download_file/view/199/165"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://applied-risk.com/resources/ar-2019-007"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2019-7672",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Prima Systems FlexAir, Versions 2.3.38 and prior. The flash version of the web interface contains a hard-coded username and password, which may allow an authenticated attacker to escalate privileges."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://applied-risk.com/labs/advisories",
"refsource": "MISC",
"url": "https://applied-risk.com/labs/advisories"
},
{
"name": "https://applied-risk.com/index.php/download_file/view/199/165",
"refsource": "MISC",
"url": "https://applied-risk.com/index.php/download_file/view/199/165"
},
{
"name": "https://applied-risk.com/resources/ar-2019-007",
"refsource": "MISC",
"url": "https://applied-risk.com/resources/ar-2019-007"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-7672",
"datePublished": "2019-06-05T18:49:42",
"dateReserved": "2019-02-09T00:00:00",
"dateUpdated": "2024-08-04T20:54:27.995Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-9189 (GCVE-0-2019-9189)
Vulnerability from cvelistv5 – Published: 2019-06-05 17:20 – Updated: 2024-08-04 21:38
VLAI?
Summary
Prima Systems FlexAir, Versions 2.4.9api3 and prior. The application allows the upload of arbitrary Python scripts when configuring the main central controller. These scripts can be immediately executed because of root code execution, not as a web server user, allowing an authenticated attacker to gain full system access.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T21:38:46.571Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://applied-risk.com/index.php/download_file/view/199/165"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://applied-risk.com/resources/ar-2019-007"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/155273/Prima-Access-Control-2.3.35-Script-Upload-Remote-Code-Execution.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Prima Systems FlexAir, Versions 2.4.9api3 and prior. The application allows the upload of arbitrary Python scripts when configuring the main central controller. These scripts can be immediately executed because of root code execution, not as a web server user, allowing an authenticated attacker to gain full system access."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-11-12T20:07:08",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://applied-risk.com/index.php/download_file/view/199/165"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://applied-risk.com/resources/ar-2019-007"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://packetstormsecurity.com/files/155273/Prima-Access-Control-2.3.35-Script-Upload-Remote-Code-Execution.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2019-9189",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Prima Systems FlexAir, Versions 2.4.9api3 and prior. The application allows the upload of arbitrary Python scripts when configuring the main central controller. These scripts can be immediately executed because of root code execution, not as a web server user, allowing an authenticated attacker to gain full system access."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://applied-risk.com/labs/advisories",
"refsource": "MISC",
"url": "https://applied-risk.com/labs/advisories"
},
{
"name": "https://applied-risk.com/index.php/download_file/view/199/165",
"refsource": "MISC",
"url": "https://applied-risk.com/index.php/download_file/view/199/165"
},
{
"name": "https://applied-risk.com/resources/ar-2019-007",
"refsource": "MISC",
"url": "https://applied-risk.com/resources/ar-2019-007"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
},
{
"name": "http://packetstormsecurity.com/files/155273/Prima-Access-Control-2.3.35-Script-Upload-Remote-Code-Execution.html",
"refsource": "MISC",
"url": "http://packetstormsecurity.com/files/155273/Prima-Access-Control-2.3.35-Script-Upload-Remote-Code-Execution.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-9189",
"datePublished": "2019-06-05T17:20:09",
"dateReserved": "2019-02-26T00:00:00",
"dateUpdated": "2024-08-04T21:38:46.571Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-7280 (GCVE-0-2019-7280)
Vulnerability from nvd – Published: 2019-07-01 18:31 – Updated: 2024-08-04 20:46
VLAI?
Summary
Prima Systems FlexAir, Versions 2.3.38 and prior. The session-ID is of an insufficient length and can be exploited by brute force, which may allow a remote attacker to obtain a valid session and bypass authentication.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:46:46.112Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.applied-risk.com/resources/ar-2019-007"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Prima Systems FlexAir, Versions 2.3.38 and prior. The session-ID is of an insufficient length and can be exploited by brute force, which may allow a remote attacker to obtain a valid session and bypass authentication."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-07-31T15:03:28",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.applied-risk.com/resources/ar-2019-007"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2019-7280",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Prima Systems FlexAir, Versions 2.3.38 and prior. The session-ID is of an insufficient length and can be exploited by brute force, which may allow a remote attacker to obtain a valid session and bypass authentication."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://applied-risk.com/labs/advisories",
"refsource": "MISC",
"url": "https://applied-risk.com/labs/advisories"
},
{
"name": "https://www.applied-risk.com/resources/ar-2019-007",
"refsource": "MISC",
"url": "https://www.applied-risk.com/resources/ar-2019-007"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-7280",
"datePublished": "2019-07-01T18:31:34",
"dateReserved": "2019-01-31T00:00:00",
"dateUpdated": "2024-08-04T20:46:46.112Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-7281 (GCVE-0-2019-7281)
Vulnerability from nvd – Published: 2019-07-01 18:29 – Updated: 2024-08-04 20:46
VLAI?
Summary
Prima Systems FlexAir, Versions 2.3.38 and prior. An unauthenticated user can send unverified HTTP requests, which may allow the attacker to perform certain actions with administrative privileges if a logged-in user visits a malicious website.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:46:45.825Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.applied-risk.com/resources/ar-2019-007"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Prima Systems FlexAir, Versions 2.3.38 and prior. An unauthenticated user can send unverified HTTP requests, which may allow the attacker to perform certain actions with administrative privileges if a logged-in user visits a malicious website."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-07-31T14:00:59",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.applied-risk.com/resources/ar-2019-007"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2019-7281",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Prima Systems FlexAir, Versions 2.3.38 and prior. An unauthenticated user can send unverified HTTP requests, which may allow the attacker to perform certain actions with administrative privileges if a logged-in user visits a malicious website."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://applied-risk.com/labs/advisories",
"refsource": "MISC",
"url": "https://applied-risk.com/labs/advisories"
},
{
"name": "https://www.applied-risk.com/resources/ar-2019-007",
"refsource": "MISC",
"url": "https://www.applied-risk.com/resources/ar-2019-007"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-7281",
"datePublished": "2019-07-01T18:29:43",
"dateReserved": "2019-01-31T00:00:00",
"dateUpdated": "2024-08-04T20:46:45.825Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-7666 (GCVE-0-2019-7666)
Vulnerability from nvd – Published: 2019-07-01 18:27 – Updated: 2024-08-04 20:54
VLAI?
Summary
Prima Systems FlexAir, Versions 2.3.38 and prior. The application allows improper authentication using the MD5 hash value of the password, which may allow an attacker with access to the database to login as admin without decrypting the password.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:54:28.425Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.applied-risk.com/resources/ar-2019-007"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/155262/Prima-FlexAir-Access-Control-2.3.35-Database-Backup-Predictable-Name.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Prima Systems FlexAir, Versions 2.3.38 and prior. The application allows improper authentication using the MD5 hash value of the password, which may allow an attacker with access to the database to login as admin without decrypting the password."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-11-12T20:07:01",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.applied-risk.com/resources/ar-2019-007"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://packetstormsecurity.com/files/155262/Prima-FlexAir-Access-Control-2.3.35-Database-Backup-Predictable-Name.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2019-7666",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Prima Systems FlexAir, Versions 2.3.38 and prior. The application allows improper authentication using the MD5 hash value of the password, which may allow an attacker with access to the database to login as admin without decrypting the password."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://applied-risk.com/labs/advisories",
"refsource": "MISC",
"url": "https://applied-risk.com/labs/advisories"
},
{
"name": "https://www.applied-risk.com/resources/ar-2019-007",
"refsource": "MISC",
"url": "https://www.applied-risk.com/resources/ar-2019-007"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
},
{
"name": "http://packetstormsecurity.com/files/155262/Prima-FlexAir-Access-Control-2.3.35-Database-Backup-Predictable-Name.html",
"refsource": "MISC",
"url": "http://packetstormsecurity.com/files/155262/Prima-FlexAir-Access-Control-2.3.35-Database-Backup-Predictable-Name.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-7666",
"datePublished": "2019-07-01T18:27:36",
"dateReserved": "2019-02-09T00:00:00",
"dateUpdated": "2024-08-04T20:54:28.425Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-7667 (GCVE-0-2019-7667)
Vulnerability from nvd – Published: 2019-07-01 18:22 – Updated: 2024-08-04 20:54
VLAI?
Summary
Prima Systems FlexAir, Versions 2.3.38 and prior. The application generates database backup files with a predictable name, and an attacker can use brute force to identify the database backup file name. A malicious actor can exploit this issue to download the database file and disclose login information, which can allow the attacker to bypass authentication and have full access to the system.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:54:28.515Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.applied-risk.com/resources/ar-2019-007"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/155262/Prima-FlexAir-Access-Control-2.3.35-Database-Backup-Predictable-Name.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Prima Systems FlexAir, Versions 2.3.38 and prior. The application generates database backup files with a predictable name, and an attacker can use brute force to identify the database backup file name. A malicious actor can exploit this issue to download the database file and disclose login information, which can allow the attacker to bypass authentication and have full access to the system."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-11-12T20:07:01",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.applied-risk.com/resources/ar-2019-007"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://packetstormsecurity.com/files/155262/Prima-FlexAir-Access-Control-2.3.35-Database-Backup-Predictable-Name.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2019-7667",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Prima Systems FlexAir, Versions 2.3.38 and prior. The application generates database backup files with a predictable name, and an attacker can use brute force to identify the database backup file name. A malicious actor can exploit this issue to download the database file and disclose login information, which can allow the attacker to bypass authentication and have full access to the system."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://applied-risk.com/labs/advisories",
"refsource": "MISC",
"url": "https://applied-risk.com/labs/advisories"
},
{
"name": "https://www.applied-risk.com/resources/ar-2019-007",
"refsource": "MISC",
"url": "https://www.applied-risk.com/resources/ar-2019-007"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
},
{
"name": "http://packetstormsecurity.com/files/155262/Prima-FlexAir-Access-Control-2.3.35-Database-Backup-Predictable-Name.html",
"refsource": "MISC",
"url": "http://packetstormsecurity.com/files/155262/Prima-FlexAir-Access-Control-2.3.35-Database-Backup-Predictable-Name.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-7667",
"datePublished": "2019-07-01T18:22:21",
"dateReserved": "2019-02-09T00:00:00",
"dateUpdated": "2024-08-04T20:54:28.515Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-7668 (GCVE-0-2019-7668)
Vulnerability from nvd – Published: 2019-07-01 18:20 – Updated: 2024-08-04 20:54
VLAI?
Summary
Prima Systems FlexAir devices have Default Credentials.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:54:28.447Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.applied-risk.com/resources/ar-2019-007"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Prima Systems FlexAir devices have Default Credentials."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-07-01T18:20:35",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.applied-risk.com/resources/ar-2019-007"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2019-7668",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Prima Systems FlexAir devices have Default Credentials."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://applied-risk.com/labs/advisories",
"refsource": "MISC",
"url": "https://applied-risk.com/labs/advisories"
},
{
"name": "https://www.applied-risk.com/resources/ar-2019-007",
"refsource": "MISC",
"url": "https://www.applied-risk.com/resources/ar-2019-007"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-7668",
"datePublished": "2019-07-01T18:20:35",
"dateReserved": "2019-02-09T00:00:00",
"dateUpdated": "2024-08-04T20:54:28.447Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-7669 (GCVE-0-2019-7669)
Vulnerability from nvd – Published: 2019-07-01 18:18 – Updated: 2024-08-04 20:54
VLAI?
Summary
Prima Systems FlexAir, Versions 2.3.38 and prior. Improper validation of file extensions when uploading files could allow a remote authenticated attacker to upload and execute malicious applications within the application’s web root with root privileges.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:54:28.438Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.applied-risk.com/resources/ar-2019-007"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/155270/FlexAir-Access-Control-2.3.38-Command-Injection.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Prima Systems FlexAir, Versions 2.3.38 and prior. Improper validation of file extensions when uploading files could allow a remote authenticated attacker to upload and execute malicious applications within the application\u2019s web root with root privileges."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-11-12T20:07:12",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.applied-risk.com/resources/ar-2019-007"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://packetstormsecurity.com/files/155270/FlexAir-Access-Control-2.3.38-Command-Injection.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2019-7669",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Prima Systems FlexAir, Versions 2.3.38 and prior. Improper validation of file extensions when uploading files could allow a remote authenticated attacker to upload and execute malicious applications within the application\u2019s web root with root privileges."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://applied-risk.com/labs/advisories",
"refsource": "MISC",
"url": "https://applied-risk.com/labs/advisories"
},
{
"name": "https://www.applied-risk.com/resources/ar-2019-007",
"refsource": "MISC",
"url": "https://www.applied-risk.com/resources/ar-2019-007"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
},
{
"name": "http://packetstormsecurity.com/files/155270/FlexAir-Access-Control-2.3.38-Command-Injection.html",
"refsource": "MISC",
"url": "http://packetstormsecurity.com/files/155270/FlexAir-Access-Control-2.3.38-Command-Injection.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-7669",
"datePublished": "2019-07-01T18:18:13",
"dateReserved": "2019-02-09T00:00:00",
"dateUpdated": "2024-08-04T20:54:28.438Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-7670 (GCVE-0-2019-7670)
Vulnerability from nvd – Published: 2019-07-01 18:12 – Updated: 2024-08-04 20:54
VLAI?
Summary
Prima Systems FlexAir, Versions 2.3.38 and prior. The application incorrectly neutralizes special elements that could modify the intended OS command when it is sent to a downstream component, which could allow attackers to execute commands directly on the operating system.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:54:28.427Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/155271/FlexAir-Access-Control-2.3.38-Remote-Root.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Prima Systems FlexAir, Versions 2.3.38 and prior. The application incorrectly neutralizes special elements that could modify the intended OS command when it is sent to a downstream component, which could allow attackers to execute commands directly on the operating system."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-11-12T20:07:10",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://packetstormsecurity.com/files/155271/FlexAir-Access-Control-2.3.38-Remote-Root.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2019-7670",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Prima Systems FlexAir, Versions 2.3.38 and prior. The application incorrectly neutralizes special elements that could modify the intended OS command when it is sent to a downstream component, which could allow attackers to execute commands directly on the operating system."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://applied-risk.com/labs/advisories",
"refsource": "MISC",
"url": "https://applied-risk.com/labs/advisories"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
},
{
"name": "http://packetstormsecurity.com/files/155271/FlexAir-Access-Control-2.3.38-Remote-Root.html",
"refsource": "MISC",
"url": "http://packetstormsecurity.com/files/155271/FlexAir-Access-Control-2.3.38-Remote-Root.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-7670",
"datePublished": "2019-07-01T18:12:44",
"dateReserved": "2019-02-09T00:00:00",
"dateUpdated": "2024-08-04T20:54:28.427Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-7671 (GCVE-0-2019-7671)
Vulnerability from nvd – Published: 2019-06-05 18:53 – Updated: 2024-08-04 20:54
VLAI?
Summary
Prima Systems FlexAir, Versions 2.3.38 and prior. Parameters sent to scripts are not properly sanitized before being returned to the user, which may allow an attacker to execute arbitrary code in a user’s browser session in context of an affected site.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:54:28.475Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://applied-risk.com/index.php/download_file/view/199/165"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://applied-risk.com/resources/ar-2019-007"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/155274/Prima-Access-Control-2.3.35-Cross-Site-Scripting.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Prima Systems FlexAir, Versions 2.3.38 and prior. Parameters sent to scripts are not properly sanitized before being returned to the user, which may allow an attacker to execute arbitrary code in a user\u2019s browser session in context of an affected site."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-11-12T20:07:02",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://applied-risk.com/index.php/download_file/view/199/165"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://applied-risk.com/resources/ar-2019-007"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://packetstormsecurity.com/files/155274/Prima-Access-Control-2.3.35-Cross-Site-Scripting.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2019-7671",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Prima Systems FlexAir, Versions 2.3.38 and prior. Parameters sent to scripts are not properly sanitized before being returned to the user, which may allow an attacker to execute arbitrary code in a user\u2019s browser session in context of an affected site."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://applied-risk.com/labs/advisories",
"refsource": "MISC",
"url": "https://applied-risk.com/labs/advisories"
},
{
"name": "https://applied-risk.com/index.php/download_file/view/199/165",
"refsource": "MISC",
"url": "https://applied-risk.com/index.php/download_file/view/199/165"
},
{
"name": "https://applied-risk.com/resources/ar-2019-007",
"refsource": "MISC",
"url": "https://applied-risk.com/resources/ar-2019-007"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
},
{
"name": "http://packetstormsecurity.com/files/155274/Prima-Access-Control-2.3.35-Cross-Site-Scripting.html",
"refsource": "MISC",
"url": "http://packetstormsecurity.com/files/155274/Prima-Access-Control-2.3.35-Cross-Site-Scripting.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-7671",
"datePublished": "2019-06-05T18:53:12",
"dateReserved": "2019-02-09T00:00:00",
"dateUpdated": "2024-08-04T20:54:28.475Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-7672 (GCVE-0-2019-7672)
Vulnerability from nvd – Published: 2019-06-05 18:49 – Updated: 2024-08-04 20:54
VLAI?
Summary
Prima Systems FlexAir, Versions 2.3.38 and prior. The flash version of the web interface contains a hard-coded username and password, which may allow an authenticated attacker to escalate privileges.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:54:27.995Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://applied-risk.com/index.php/download_file/view/199/165"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://applied-risk.com/resources/ar-2019-007"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Prima Systems FlexAir, Versions 2.3.38 and prior. The flash version of the web interface contains a hard-coded username and password, which may allow an authenticated attacker to escalate privileges."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-07-31T15:06:34",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://applied-risk.com/index.php/download_file/view/199/165"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://applied-risk.com/resources/ar-2019-007"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2019-7672",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Prima Systems FlexAir, Versions 2.3.38 and prior. The flash version of the web interface contains a hard-coded username and password, which may allow an authenticated attacker to escalate privileges."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://applied-risk.com/labs/advisories",
"refsource": "MISC",
"url": "https://applied-risk.com/labs/advisories"
},
{
"name": "https://applied-risk.com/index.php/download_file/view/199/165",
"refsource": "MISC",
"url": "https://applied-risk.com/index.php/download_file/view/199/165"
},
{
"name": "https://applied-risk.com/resources/ar-2019-007",
"refsource": "MISC",
"url": "https://applied-risk.com/resources/ar-2019-007"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-7672",
"datePublished": "2019-06-05T18:49:42",
"dateReserved": "2019-02-09T00:00:00",
"dateUpdated": "2024-08-04T20:54:27.995Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-9189 (GCVE-0-2019-9189)
Vulnerability from nvd – Published: 2019-06-05 17:20 – Updated: 2024-08-04 21:38
VLAI?
Summary
Prima Systems FlexAir, Versions 2.4.9api3 and prior. The application allows the upload of arbitrary Python scripts when configuring the main central controller. These scripts can be immediately executed because of root code execution, not as a web server user, allowing an authenticated attacker to gain full system access.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T21:38:46.571Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://applied-risk.com/index.php/download_file/view/199/165"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://applied-risk.com/resources/ar-2019-007"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/155273/Prima-Access-Control-2.3.35-Script-Upload-Remote-Code-Execution.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Prima Systems FlexAir, Versions 2.4.9api3 and prior. The application allows the upload of arbitrary Python scripts when configuring the main central controller. These scripts can be immediately executed because of root code execution, not as a web server user, allowing an authenticated attacker to gain full system access."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-11-12T20:07:08",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://applied-risk.com/labs/advisories"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://applied-risk.com/index.php/download_file/view/199/165"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://applied-risk.com/resources/ar-2019-007"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://packetstormsecurity.com/files/155273/Prima-Access-Control-2.3.35-Script-Upload-Remote-Code-Execution.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2019-9189",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Prima Systems FlexAir, Versions 2.4.9api3 and prior. The application allows the upload of arbitrary Python scripts when configuring the main central controller. These scripts can be immediately executed because of root code execution, not as a web server user, allowing an authenticated attacker to gain full system access."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://applied-risk.com/labs/advisories",
"refsource": "MISC",
"url": "https://applied-risk.com/labs/advisories"
},
{
"name": "https://applied-risk.com/index.php/download_file/view/199/165",
"refsource": "MISC",
"url": "https://applied-risk.com/index.php/download_file/view/199/165"
},
{
"name": "https://applied-risk.com/resources/ar-2019-007",
"refsource": "MISC",
"url": "https://applied-risk.com/resources/ar-2019-007"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-211-02"
},
{
"name": "http://packetstormsecurity.com/files/155273/Prima-Access-Control-2.3.35-Script-Upload-Remote-Code-Execution.html",
"refsource": "MISC",
"url": "http://packetstormsecurity.com/files/155273/Prima-Access-Control-2.3.35-Script-Upload-Remote-Code-Execution.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-9189",
"datePublished": "2019-06-05T17:20:09",
"dateReserved": "2019-02-26T00:00:00",
"dateUpdated": "2024-08-04T21:38:46.571Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}