cve-2023-4562
Vulnerability from cvelistv5
Published
2023-10-13 01:26
Modified
2024-08-02 07:31
Severity ?
Summary
Improper Authentication vulnerability in Mitsubishi Electric Corporation MELSEC-F Series main modules allows a remote unauthenticated attacker to obtain sequence programs from the product or write malicious sequence programs or improper data in the product without authentication by sending illegitimate messages.
Impacted products
Vendor Product Version
Mitsubishi Electric Corporation MELSEC-F Series FX3U-32MT/ES Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3U-48MT/ES Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3U-64MT/ES Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3U-80MT/ES Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3U-128MT/ES Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3U-16MR/ES Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3U-32MR/ES Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3U-48MR/ES Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3U-64MR/ES Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3U-80MR/ES Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3U-128MR/ES Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3U-16MT/ESS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3U-32MT/ESS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3U-48MT/ESS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3U-64MT/ESS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3U-80MT/ESS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3U-128MT/ESS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3U-16MT/DS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3U-32MT/DS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3U-48MT/DS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3U-64MT/DS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3U-80MT/DS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3U-128MT/DS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3U-16MR/DS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3U-32MR/DS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3U-48MR/DS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3U-64MR/DS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3U-80MR/DS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3U-128MR/DS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3U-16MT/DSS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3U-32MT/DSS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3U-48MT/DSS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3U-64MT/DSS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3U-80MT/DSS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3U-128MT/DSS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3U-32MR/UA1 Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3U-64MR/UA1 Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3U-32MS/ES Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3U-64MS/ES Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3U-16MT/ES-A Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3U-32MT/ES-A Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3U-48MT/ES-A Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3U-64MT/ES-A Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3U-80MT/ES-A Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3U-128MT/ES-A Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3U-16MR/ES-A Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3U-32MR/ES-A Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3U-48MR/ES-A Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3U-64MR/ES-A Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3U-80MR/ES-A Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3U-128MR/ES-A Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3UC-16MT/D Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3UC-32MT/D Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3UC-64MT/D Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3UC-96MT/D Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3UC-16MT/DSS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3UC-32MT/DSS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3UC-64MT/DSS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3UC-96MT/DSS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3UC-16MR/D-T Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3UC-16MR/DS-T Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3UC-32MT-LT Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3UC-32MT-LT-2 Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3UC-16MT/D-P4 Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3UC-16MT/DSS-P4 Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3G-14MT/ES Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3G-24MT/ES Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3G-40MT/ES Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3G-60MT/ES Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3G-14MR/ES Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3G-24MR/ES Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3G-40MR/ES Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3G-60MR/ES Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3G-14MT/ESS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3G-24MT/ESS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3G-40MT/ESS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3G-60MT/ESS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3G-14MT/DS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3G-24MT/DS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3G-40MT/DS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3G-60MT/DS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3G-14MR/DS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3G-24MR/DS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3G-40MR/DS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3G-60MR/DS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3G-14MT/DSS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3G-24MT/DSS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3G-40MT/DSS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3G-60MT/DSS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3G-14MT/ES-A Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3G-24MT/ES-A Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3G-40MT/ES-A Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3G-60MT/ES-A Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3G-14MR/ES-A Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3G-24MR/ES-A Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3G-40MR/ES-A Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3G-60MR/ES-A Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3GC-32MT/D Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3GC-32MT/DSS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3GE-24MT/ES Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3GE-40MT/ES Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3GE-24MR/ES Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3GE-40MR/ES Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3GE-24MT/ESS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3GE-40MT/ESS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3GE-24MT/DS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3GE-40MT/DS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3GE-24MR/DS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3GE-40MR/DS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3GE-24MT/DSS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3GE-40MT/DSS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3GA-24MT-CM Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3GA-40MT-CM Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3GA-60MT-CM Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3GA-24MR-CM Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3GA-40MR-CM Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3GA-60MR-CM Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3S-10MT/ES Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3S-14MT/ES Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3S-20MT/ES Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3S-30MT/ES Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3S-10MR/ES Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3S-14MR/ES Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3S-20MR/ES Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3S-30MR/ES Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3S-10MT/ESS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3S-14MT/ESS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3S-20MT/ESS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3S-30MT/ESS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3S-10MT/DS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3S-14MT/DS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3S-20MT/DS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3S-30MT/DS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3S-10MR/DS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3S-14MR/DS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3S-20MR/DS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3S-30MR/DS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3S-10MT/DSS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3S-14MT/DSS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3S-20MT/DSS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3S-30MT/DSS Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3S-30MT/ES-2AD Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3S-30MR/ES-2AD Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3S-30MT/ESS-2AD Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3SA-10MT-CM Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3SA-14MT-CM Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3SA-20MT-CM Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3SA-30MT-CM Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3SA-10MR-CM Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3SA-14MR-CM Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3SA-20MR-CM Version: all versions
Mitsubishi Electric Corporation MELSEC-F Series FX3SA-30MR-CM Version: all versions
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T07:31:06.356Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-012_en.pdf"
          },
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://jvn.jp/vu/JVNVU90509290/"
          },
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-285-13"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3U-16MT/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3U-32MT/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3U-48MT/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3U-64MT/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3U-80MT/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3U-128MT/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3U-16MR/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3U-32MR/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3U-48MR/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3U-64MR/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3U-80MR/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3U-128MR/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3U-16MT/ESS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3U-32MT/ESS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3U-48MT/ESS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3U-64MT/ESS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3U-80MT/ESS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3U-128MT/ESS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3U-16MT/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3U-32MT/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3U-48MT/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3U-64MT/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3U-80MT/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3U-128MT/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3U-16MR/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3U-32MR/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3U-48MR/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3U-64MR/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3U-80MR/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3U-128MR/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3U-16MT/DSS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3U-32MT/DSS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3U-48MT/DSS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3U-64MT/DSS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3U-80MT/DSS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3U-128MT/DSS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3U-32MR/UA1",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3U-64MR/UA1",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3U-32MS/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3U-64MS/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3U-16MT/ES-A",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3U-32MT/ES-A",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3U-48MT/ES-A",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3U-64MT/ES-A",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3U-80MT/ES-A",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3U-128MT/ES-A",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3U-16MR/ES-A",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3U-32MR/ES-A",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3U-48MR/ES-A",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3U-64MR/ES-A",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3U-80MR/ES-A",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3U-128MR/ES-A",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3UC-16MT/D",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3UC-32MT/D",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3UC-64MT/D",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3UC-96MT/D",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3UC-16MT/DSS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3UC-32MT/DSS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3UC-64MT/DSS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3UC-96MT/DSS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3UC-16MR/D-T",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3UC-16MR/DS-T",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3UC-32MT-LT",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3UC-32MT-LT-2",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3UC-16MT/D-P4",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3UC-16MT/DSS-P4",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3G-14MT/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3G-24MT/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3G-40MT/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3G-60MT/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3G-14MR/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3G-24MR/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3G-40MR/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3G-60MR/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3G-14MT/ESS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3G-24MT/ESS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3G-40MT/ESS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3G-60MT/ESS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3G-14MT/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3G-24MT/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3G-40MT/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3G-60MT/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3G-14MR/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3G-24MR/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3G-40MR/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3G-60MR/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3G-14MT/DSS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3G-24MT/DSS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3G-40MT/DSS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3G-60MT/DSS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3G-14MT/ES-A",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3G-24MT/ES-A",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3G-40MT/ES-A",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3G-60MT/ES-A",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3G-14MR/ES-A",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3G-24MR/ES-A",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3G-40MR/ES-A",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3G-60MR/ES-A",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3GC-32MT/D",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3GC-32MT/DSS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3GE-24MT/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3GE-40MT/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3GE-24MR/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3GE-40MR/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3GE-24MT/ESS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3GE-40MT/ESS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3GE-24MT/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3GE-40MT/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3GE-24MR/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3GE-40MR/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3GE-24MT/DSS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3GE-40MT/DSS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3GA-24MT-CM",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3GA-40MT-CM",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3GA-60MT-CM",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3GA-24MR-CM",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3GA-40MR-CM",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3GA-60MR-CM",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3S-10MT/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3S-14MT/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3S-20MT/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3S-30MT/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3S-10MR/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3S-14MR/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3S-20MR/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3S-30MR/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3S-10MT/ESS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3S-14MT/ESS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3S-20MT/ESS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3S-30MT/ESS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3S-10MT/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3S-14MT/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3S-20MT/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3S-30MT/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3S-10MR/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3S-14MR/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3S-20MR/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3S-30MR/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3S-10MT/DSS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3S-14MT/DSS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3S-20MT/DSS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3S-30MT/DSS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3S-30MT/ES-2AD",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3S-30MR/ES-2AD",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3S-30MT/ESS-2AD",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3SA-10MT-CM",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3SA-14MT-CM",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3SA-20MT-CM",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3SA-30MT-CM",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3SA-10MR-CM",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3SA-14MR-CM",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3SA-20MR-CM",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC-F Series FX3SA-30MR-CM",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Improper Authentication vulnerability in Mitsubishi Electric Corporation MELSEC-F Series main modules allows a remote unauthenticated attacker to obtain sequence programs from the product or write malicious sequence programs or improper data in the product without authentication by sending illegitimate messages.\u003cbr\u003e\n\n\n\n\n\n"
            }
          ],
          "value": "Improper Authentication vulnerability in Mitsubishi Electric Corporation MELSEC-F Series main modules allows a remote unauthenticated attacker to obtain sequence programs from the product or write malicious sequence programs or improper data in the product without authentication by sending illegitimate messages.\n\n\n\n\n\n\n"
        }
      ],
      "impacts": [
        {
          "descriptions": [
            {
              "lang": "en",
              "value": "Information Disclosure, Information Tampering and Authentication Bypass"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "CWE-287 Improper Authentication",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-10-13T01:26:06.018Z",
        "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "shortName": "Mitsubishi"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-012_en.pdf"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://jvn.jp/vu/JVNVU90509290/"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-285-13"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Information Disclosure, Information Tampering and Authentication Bypass Vulnerability in MELSEC-F Series main module",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
    "assignerShortName": "Mitsubishi",
    "cveId": "CVE-2023-4562",
    "datePublished": "2023-10-13T01:26:06.018Z",
    "dateReserved": "2023-08-28T01:49:36.225Z",
    "dateUpdated": "2024-08-02T07:31:06.356Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-20612
Vulnerability from cvelistv5
Published
2022-01-14 19:04
Modified
2024-08-03 17:45
Severity ?
Summary
Lack of administrator control over security vulnerability in MELSEC-F series FX3U-ENET Firmware version 1.14 and prior, FX3U-ENET-L Firmware version 1.14 and prior and FX3U-ENET-P502 Firmware version 1.14 and prior allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition in communication function of the product or other unspecified effects by sending specially crafted packets to an unnecessary opening of TCP port. Control by MELSEC-F series PLC is not affected by this vulnerability, but system reset is required for recovery.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T17:45:44.790Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-023_en.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://jvn.jp/vu/JVNVU93268332/index.html"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-013-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "MELSEC-F series FX3U-ENET; MELSEC-F series FX3U-ENET-L; MELSEC-F series FX3U-ENET-P502",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Firmware version 1.14 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Lack of administrator control over security vulnerability in MELSEC-F series FX3U-ENET Firmware version 1.14 and prior, FX3U-ENET-L Firmware version 1.14 and prior and FX3U-ENET-P502 Firmware version 1.14 and prior allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition in communication function of the product or other unspecified effects by sending specially crafted packets to an unnecessary opening of TCP port. Control by MELSEC-F series PLC is not affected by this vulnerability, but system reset is required for recovery."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Lack of Administrator Control over Security",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-01-14T19:04:45",
        "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "shortName": "Mitsubishi"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-023_en.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://jvn.jp/vu/JVNVU93268332/index.html"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-013-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
          "ID": "CVE-2021-20612",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "MELSEC-F series FX3U-ENET; MELSEC-F series FX3U-ENET-L; MELSEC-F series FX3U-ENET-P502",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Firmware version 1.14 and prior"
                          },
                          {
                            "version_value": "Firmware version 1.14 and prior"
                          },
                          {
                            "version_value": "Firmware version 1.14 and prior"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Lack of administrator control over security vulnerability in MELSEC-F series FX3U-ENET Firmware version 1.14 and prior, FX3U-ENET-L Firmware version 1.14 and prior and FX3U-ENET-P502 Firmware version 1.14 and prior allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition in communication function of the product or other unspecified effects by sending specially crafted packets to an unnecessary opening of TCP port. Control by MELSEC-F series PLC is not affected by this vulnerability, but system reset is required for recovery."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Lack of Administrator Control over Security"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-023_en.pdf",
              "refsource": "MISC",
              "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-023_en.pdf"
            },
            {
              "name": "https://jvn.jp/vu/JVNVU93268332/index.html",
              "refsource": "MISC",
              "url": "https://jvn.jp/vu/JVNVU93268332/index.html"
            },
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-013-01",
              "refsource": "MISC",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-013-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
    "assignerShortName": "Mitsubishi",
    "cveId": "CVE-2021-20612",
    "datePublished": "2022-01-14T19:04:45",
    "dateReserved": "2020-12-17T00:00:00",
    "dateUpdated": "2024-08-03T17:45:44.790Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-20613
Vulnerability from cvelistv5
Published
2022-01-14 19:04
Modified
2024-08-03 17:45
Severity ?
Summary
Improper initialization vulnerability in MELSEC-F series FX3U-ENET Firmware version 1.16 and prior, FX3U-ENET-L Firmware version 1.16 and prior and FX3U-ENET-P502 Firmware version 1.16 and prior allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition in communication function of the product by sending specially crafted packets. Control by MELSEC-F series PLC is not affected by this vulnerability, but system reset is required for recovery.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T17:45:44.677Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://jvn.jp/vu/JVNVU93268332/index.html"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-024_en.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-013-07"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "MELSEC-F series FX3U-ENET; MELSEC-F series FX3U-ENET-L; MELSEC-F series FX3U-ENET-P502",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Firmware version 1.16 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Improper initialization vulnerability in MELSEC-F series FX3U-ENET Firmware version 1.16 and prior, FX3U-ENET-L Firmware version 1.16 and prior and FX3U-ENET-P502 Firmware version 1.16 and prior allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition in communication function of the product by sending specially crafted packets. Control by MELSEC-F series PLC is not affected by this vulnerability, but system reset is required for recovery."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Improper Initialization",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-01-14T19:04:47",
        "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "shortName": "Mitsubishi"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://jvn.jp/vu/JVNVU93268332/index.html"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-024_en.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-013-07"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
          "ID": "CVE-2021-20613",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "MELSEC-F series FX3U-ENET; MELSEC-F series FX3U-ENET-L; MELSEC-F series FX3U-ENET-P502",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Firmware version 1.16 and prior"
                          },
                          {
                            "version_value": "Firmware version 1.16 and prior"
                          },
                          {
                            "version_value": "Firmware version 1.16 and prior"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Improper initialization vulnerability in MELSEC-F series FX3U-ENET Firmware version 1.16 and prior, FX3U-ENET-L Firmware version 1.16 and prior and FX3U-ENET-P502 Firmware version 1.16 and prior allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition in communication function of the product by sending specially crafted packets. Control by MELSEC-F series PLC is not affected by this vulnerability, but system reset is required for recovery."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Improper Initialization"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://jvn.jp/vu/JVNVU93268332/index.html",
              "refsource": "MISC",
              "url": "https://jvn.jp/vu/JVNVU93268332/index.html"
            },
            {
              "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-024_en.pdf",
              "refsource": "MISC",
              "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-024_en.pdf"
            },
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-013-07",
              "refsource": "MISC",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-013-07"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
    "assignerShortName": "Mitsubishi",
    "cveId": "CVE-2021-20613",
    "datePublished": "2022-01-14T19:04:47",
    "dateReserved": "2020-12-17T00:00:00",
    "dateUpdated": "2024-08-03T17:45:44.677Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2020-16226
Vulnerability from cvelistv5
Published
2020-10-05 17:19
Modified
2024-09-17 00:25
Severity ?
Summary
Multiple Mitsubishi Electric products are vulnerable to impersonations of a legitimate device by a malicious actor, which may allow an attacker to remotely execute arbitrary commands.
References
Impacted products
Vendor Product Version
Mitsubishi Electric QJ71WS96 Version: all versions
Mitsubishi Electric Q06CCPU-V Version: all versions
Mitsubishi Electric Q24DHCCPU-V Version: all versions
Mitsubishi Electric Q24DHCCPU-VG Version: all versions
Mitsubishi Electric R12CCPU-V Version: all versions
Mitsubishi Electric RD55UP06-V, Version: all versions
Mitsubishi Electric D55UP12-V Version: all versions
Mitsubishi Electric RJ71GN11-T2 Version: all versions
Mitsubishi Electric RJ71EN71 Version: all versions
Mitsubishi Electric QJ71E71-100 Version: all versions
Mitsubishi Electric LJ71E71-100 Version: all versions
Mitsubishi Electric QJ71MT91 Version: all versions
Mitsubishi Electric RD78Gn(n=4,8,16,32,64) Version: all versions
Mitsubishi Electric RD78GHV Version: all versions
Mitsubishi Electric RD78GHW Version: all versions
Mitsubishi Electric NZ2GACP620-60 Version: all versions
Mitsubishi Electric NZ2GACP620-300 Version: all versions
Mitsubishi Electric NZ2FT-MT Version: all versions
Mitsubishi Electric NZ2FT-EIP Version: all versions
Mitsubishi Electric Q03UDECPU Version: the first 5 digits of serial number 22081 and prior
Mitsubishi Electric QnUDEHCPU(n=04/06/10/13/20/26/50/100) Version: the first 5 digits of serial number 22081 and prior
Mitsubishi Electric QnUDVCPU(n=03/04/06/13/26) Version: the first 5 digits of serial number 22031 and prior
Mitsubishi Electric QnUDPVCPU(n=04/06/13/2) Version: the first 5 digits of serial number 22031 and prior
Mitsubishi Electric LnCPU(-P)(n=02/06/26) Version: the first 5 digits of serial number 22051 and prior
Mitsubishi Electric L26CPU-(P)BT Version: the first 5 digits of serial number 22051 and prior
Mitsubishi Electric RnCPU(n=00/01/02) Version: unspecified   < Version 18 and prior
Mitsubishi Electric RnCPU(n=04/08/16/32/120) Version: unspecified   < Version 50 and prior
Mitsubishi Electric RnENCPU(n=04/08/16/32/120) Version: unspecified   < Version 50 and prior
Mitsubishi Electric RnSFCPU (n=08/16/32/120) Version: all versions
Mitsubishi Electric RnPCPU(n=08/16/32/120) Version: all versions
Mitsubishi Electric RnPSFCPU(n=08/16/32/120) Version: all versions
Mitsubishi Electric FX5U(C)-**M*/** Version: unspecified   < Serial number 17X**** or later: Version 1.210 and prior
Version: unspecified   < Serial number 179**** and prior: Version 1.070 and prior
Mitsubishi Electric FX5UC-32M*/**-TS Version: unspecified   < Version 1.210 and prior
Mitsubishi Electric FX5UJ-**M*/** Version: Version 1.000
Mitsubishi Electric FX5-ENET Version: all versions
Mitsubishi Electric FX5-ENET/IP Version: all versions
Mitsubishi Electric FX3U-ENET-ADP Version: all versions
Mitsubishi Electric FX3GE-**M*/** Version: all versions
Mitsubishi Electric FX3U-ENET Version: all versions
Mitsubishi Electric FX3U-ENET-L Version: all versions
Mitsubishi Electric FX3U-ENET-P502 Version: all versions
Mitsubishi Electric FX5-CCLGN-MS Version: all versions
Mitsubishi Electric IU1-1M20-D Version: all versions
Mitsubishi Electric LE7-40GU-L Version: all versions
Mitsubishi Electric GOT2000 Series GT21 Model Version: all versions
Mitsubishi Electric GS Series Version: all versions
Mitsubishi Electric GOT1000 Series GT14 Model Version: all versions
Mitsubishi Electric GT25-J71GN13-T2 Version: all versions
Mitsubishi Electric FR-A800-E Series Version: all versions
Mitsubishi Electric FR-F800-E Series Version: all versions
Mitsubishi Electric FR-A8NCG Version: Production date August 2020 and prior
Mitsubishi Electric FR-E800-EPA Series Version: Production date July 2020 and prior
Mitsubishi Electric FR-E800-EPB Series Version: Production date July 2020 and prior
Mitsubishi Electric Conveyor Tracking Application Version: APR-nTR3FH all versions
Version: APR-nTR6FH all versions
Version: APR-nTR12FH all versions
Version: APR-nTR20FH(n=1,2) all versions
Mitsubishi Electric MR-JE-C Version: all versions
Mitsubishi Electric MR-J4-TM Version: all versions
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T13:37:54.189Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-245-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "QJ71MES96",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "QJ71WS96",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "Q06CCPU-V",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "Q24DHCCPU-V",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "Q24DHCCPU-VG",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "R12CCPU-V",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "RD55UP06-V,",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "D55UP12-V",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "RJ71GN11-T2",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "RJ71EN71",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "QJ71E71-100",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "LJ71E71-100",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "QJ71MT91",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "RD78Gn(n=4,8,16,32,64)",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "RD78GHV",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "RD78GHW",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "NZ2GACP620-60",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "NZ2GACP620-300",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "NZ2FT-MT",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "NZ2FT-EIP",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "Q03UDECPU",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "the first 5 digits of serial number 22081 and prior"
            }
          ]
        },
        {
          "product": "QnUDEHCPU(n=04/06/10/13/20/26/50/100)",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "the first 5 digits of serial number 22081 and prior"
            }
          ]
        },
        {
          "product": "QnUDVCPU(n=03/04/06/13/26)",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "the first 5 digits of serial number 22031 and prior"
            }
          ]
        },
        {
          "product": "QnUDPVCPU(n=04/06/13/2)",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "the first 5 digits of serial number 22031 and prior"
            }
          ]
        },
        {
          "product": "LnCPU(-P)(n=02/06/26)",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "the first 5 digits of serial number 22051 and prior"
            }
          ]
        },
        {
          "product": "L26CPU-(P)BT",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "the first 5 digits of serial number 22051 and prior"
            }
          ]
        },
        {
          "product": "RnCPU(n=00/01/02)",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThan": "Version 18 and prior",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "RnCPU(n=04/08/16/32/120)",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThan": "Version 50 and prior",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "RnENCPU(n=04/08/16/32/120)",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThan": "Version 50 and prior",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "RnSFCPU (n=08/16/32/120)",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "RnPCPU(n=08/16/32/120)",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "RnPSFCPU(n=08/16/32/120)",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "FX5U(C)-**M*/**",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThan": "Serial number 17X**** or later: Version 1.210 and prior",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            },
            {
              "lessThan": "Serial number 179**** and prior: Version 1.070 and prior",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "FX5UC-32M*/**-TS",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThan": "Version 1.210 and prior",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "FX5UJ-**M*/**",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Version 1.000"
            }
          ]
        },
        {
          "product": "FX5-ENET",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "FX5-ENET/IP",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "FX3U-ENET-ADP",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "FX3GE-**M*/**",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "FX3U-ENET",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "FX3U-ENET-L",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "FX3U-ENET-P502",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "FX5-CCLGN-MS",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "IU1-1M20-D",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "LE7-40GU-L",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "GOT2000 Series GT21 Model",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "GS Series",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "GOT1000 Series GT14 Model",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "GT25-J71GN13-T2",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "FR-A800-E Series",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "FR-F800-E Series",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "FR-A8NCG",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Production date August 2020 and prior"
            }
          ]
        },
        {
          "product": "FR-E800-EPA Series",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Production date July 2020 and prior"
            }
          ]
        },
        {
          "product": "FR-E800-EPB Series",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Production date July 2020 and prior"
            }
          ]
        },
        {
          "product": "Conveyor Tracking Application",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "APR-nTR3FH all versions"
            },
            {
              "status": "affected",
              "version": "APR-nTR6FH all versions"
            },
            {
              "status": "affected",
              "version": "APR-nTR12FH all versions"
            },
            {
              "status": "affected",
              "version": "APR-nTR20FH(n=1,2) all versions"
            }
          ]
        },
        {
          "product": "MR-JE-C",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "product": "MR-J4-TM",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        }
      ],
      "datePublic": "2020-09-01T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Multiple Mitsubishi Electric products are vulnerable to impersonations of a legitimate device by a malicious actor, which may allow an attacker to remotely execute arbitrary commands."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-342",
              "description": "PREDICTABLE EXACT VALUE FROM PREVIOUS VALUES CWE-342",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-10-05T17:19:17",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-245-01"
        }
      ],
      "source": {
        "advisory": "ICSA-20-245-01",
        "discovery": "UNKNOWN"
      },
      "title": "Mitsubishi Electric Multiple Products",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2020-09-01T16:00:00.000Z",
          "ID": "CVE-2020-16226",
          "STATE": "PUBLIC",
          "TITLE": "Mitsubishi Electric Multiple Products"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "QJ71MES96",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "QJ71WS96",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Q06CCPU-V",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Q24DHCCPU-V",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Q24DHCCPU-VG",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "R12CCPU-V",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "RD55UP06-V,",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "D55UP12-V",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "RJ71GN11-T2",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "RJ71EN71",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "QJ71E71-100",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "LJ71E71-100",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "QJ71MT91",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "RD78Gn(n=4,8,16,32,64)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "RD78GHV",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "RD78GHW",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "NZ2GACP620-60",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "NZ2GACP620-300",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "NZ2FT-MT",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "NZ2FT-EIP",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Q03UDECPU",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "the first 5 digits of serial number 22081 and prior"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "QnUDEHCPU(n=04/06/10/13/20/26/50/100)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "the first 5 digits of serial number 22081 and prior"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "QnUDVCPU(n=03/04/06/13/26)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "the first 5 digits of serial number 22031 and prior"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "QnUDPVCPU(n=04/06/13/2)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "the first 5 digits of serial number 22031 and prior"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "LnCPU(-P)(n=02/06/26)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "the first 5 digits of serial number 22051 and prior"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "L26CPU-(P)BT",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "the first 5 digits of serial number 22051 and prior"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "RnCPU(n=00/01/02)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "Version 18 and prior"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "RnCPU(n=04/08/16/32/120)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "Version 50 and prior"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "RnENCPU(n=04/08/16/32/120)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "Version 50 and prior"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "RnSFCPU (n=08/16/32/120)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "RnPCPU(n=08/16/32/120)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "RnPSFCPU(n=08/16/32/120)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "FX5U(C)-**M*/**",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "Serial number 17X**** or later: Version 1.210 and prior"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_value": "Serial number 179**** and prior: Version 1.070 and prior"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "FX5UC-32M*/**-TS",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "Version 1.210 and prior"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "FX5UJ-**M*/**",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "Version 1.000"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "FX5-ENET",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "FX5-ENET/IP",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "FX3U-ENET-ADP",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "FX3GE-**M*/**",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "FX3U-ENET",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "FX3U-ENET-L",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "FX3U-ENET-P502",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "FX5-CCLGN-MS",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "IU1-1M20-D",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "LE7-40GU-L",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "GOT2000 Series GT21 Model",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "GS Series",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "GOT1000 Series GT14 Model",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "GT25-J71GN13-T2",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "FR-A800-E Series",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "FR-F800-E Series",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "FR-A8NCG",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "Production date August 2020 and prior"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "FR-E800-EPA Series",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "Production date July 2020 and prior"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "FR-E800-EPB Series",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "Production date July 2020 and prior"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Conveyor Tracking Application",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_name": "APR-nTR3FH",
                            "version_value": "all versions"
                          },
                          {
                            "version_affected": "=",
                            "version_name": "APR-nTR6FH",
                            "version_value": "all versions"
                          },
                          {
                            "version_affected": "=",
                            "version_name": "APR-nTR12FH",
                            "version_value": "all versions"
                          },
                          {
                            "version_affected": "=",
                            "version_name": "APR-nTR20FH(n=1,2)",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "MR-JE-C",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "MR-J4-TM",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all versions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Mitsubishi Electric"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Multiple Mitsubishi Electric products are vulnerable to impersonations of a legitimate device by a malicious actor, which may allow an attacker to remotely execute arbitrary commands."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "PREDICTABLE EXACT VALUE FROM PREVIOUS VALUES CWE-342"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-245-01",
              "refsource": "MISC",
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-245-01"
            }
          ]
        },
        "source": {
          "advisory": "ICSA-20-245-01",
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2020-16226",
    "datePublished": "2020-10-05T17:19:17.358565Z",
    "dateReserved": "2020-07-31T00:00:00",
    "dateUpdated": "2024-09-17T00:25:38.551Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Vulnerability from fkie_nvd
Published
2020-10-05 18:15
Modified
2024-11-21 05:06
Severity ?
Summary
Multiple Mitsubishi Electric products are vulnerable to impersonations of a legitimate device by a malicious actor, which may allow an attacker to remotely execute arbitrary commands.
References
Impacted products
Vendor Product Version
mitsubishielectric qj71mes96_firmware *
mitsubishielectric qj71mes96 -
mitsubishielectric qj71ws96_firmware *
mitsubishielectric qj71ws96 -
mitsubishielectric q06ccpu-v_firmware *
mitsubishielectric q06ccpu-v -
mitsubishielectric q24dhccpu-v_firmware *
mitsubishielectric q24dhccpu-v -
mitsubishielectric q24dhccpu-vg_firmware *
mitsubishielectric q24dhccpu-vg -
mitsubishielectric r12ccpu-v_firmware *
mitsubishielectric r12ccpu-v -
mitsubishielectric rd55up06-v_firmware *
mitsubishielectric rd55up06-v -
mitsubishielectric rd55up12-v_firmware *
mitsubishielectric rd55up12-v -
mitsubishielectric rj71gn11-t2_firmware *
mitsubishielectric rj71gn11-t2 -
mitsubishielectric rj71en71_firmware *
mitsubishielectric rj71en71 -
mitsubishielectric qj71e71-100_firmware *
mitsubishielectric qj71e71-100 -
mitsubishielectric lj71e71-100_firmware *
mitsubishielectric lj71e71-100 -
mitsubishielectric qj71mt91_firmware *
mitsubishielectric qj71mt91 -
mitsubishielectric rd78gn\(n\=4\,8\,16\,32\,64\)_firmware *
mitsubishielectric rd78gn\(n\=4\,8\,16\,32\,64\) -
mitsubishielectric rd78ghv_firmware *
mitsubishielectric rd78ghv -
mitsubishielectric rd78ghw_firmware *
mitsubishielectric rd78ghw -
mitsubishielectric nz2gacp620-60_firmware *
mitsubishielectric nz2gacp620-60 -
mitsubishielectric nz2gacp620-300_firmware *
mitsubishielectric nz2gacp620-300 -
mitsubishielectric nz2ft-mt_firmware *
mitsubishielectric nz2ft-mt -
mitsubishielectric nz2ft-eip_firmware *
mitsubishielectric nz2ft-eip -
mitsubishielectric q03udecpu_firmware *
mitsubishielectric q03udecpu -
mitsubishielectric qnudehcpu\(n\=04\/06\/10\/13\/20\/26\/50\/100\)_firmware *
mitsubishielectric qnudehcpu\(n\=04\/06\/10\/13\/20\/26\/50\/100\) -
mitsubishielectric qnudvcpu\(n\=03\/04\/06\/13\/26\)_firmware *
mitsubishielectric qnudvcpu\(n\=03\/04\/06\/13\/26\) -
mitsubishielectric qnudpvcpu\(n\=04\/06\/13\/2\)_firmware *
mitsubishielectric qnudpvcpu\(n\=04\/06\/13\/2\) -
mitsubishielectric lncpu\(-p\)\(n\=02\/06\/26\)_firmware *
mitsubishielectric lncpu\(-p\)\(n\=02\/06\/26\) -
mitsubishielectric l26cpu-\(p\)bt_firmware *
mitsubishielectric l26cpu-\(p\)bt -
mitsubishielectric rncpu\(n\=00\/01\/02\)t_firmware *
mitsubishielectric rncpu\(n\=00\/01\/02\)t -
mitsubishielectric rncpu\(n\=04\/08\/16\/32\/120\)_firmware *
mitsubishielectric rncpu\(n\=04\/08\/16\/32\/120\) -
mitsubishielectric rnencpu\(n\=04\/08\/16\/32\/120\)_firmware *
mitsubishielectric rnencpu\(n\=04\/08\/16\/32\/120\) -
mitsubishielectric rnsfcpu_\(n\=08\/16\/32\/120\)_firmware *
mitsubishielectric rnsfcpu_\(n\=08\/16\/32\/120\) -
mitsubishielectric rnpcpu\(n\=08\/16\/32\/120\)_firmware *
mitsubishielectric rnpcpu\(n\=08\/16\/32\/120\) -
mitsubishielectric rnpsfcpu\(n\=08\/16\/32\/120\)_firmware *
mitsubishielectric rnpsfcpu\(n\=08\/16\/32\/120\) -
mitsubishielectric fx5uc-32mt\/d_firmware 1.210
mitsubishielectric fx5uc-32mt\/d -
mitsubishielectric fx5uc-32mt\/dss_firmware 1.210
mitsubishielectric fx5uc-32mt\/dss -
mitsubishielectric fx5uc-32mt\/ds-ts_firmware 1.210
mitsubishielectric fx5uc-32mt\/ds-ts -
mitsubishielectric fx5uc-32mt\/dss-ts_firmware 1.210
mitsubishielectric fx5uc-32mt\/dss-ts -
mitsubishielectric fx5uj-24mr\/es_firmware 1.000
mitsubishielectric fx5uj-24mr\/es -
mitsubishielectric fx5uc-32mr\/ds-ts_firmware 1.210
mitsubishielectric fx5uc-32mr\/ds-ts -
mitsubishielectric fx5uj-24mt\/es_firmware 1.000
mitsubishielectric fx5uj-24mt\/es -
mitsubishielectric fx5uj-24mt\/ess_firmware 1.000
mitsubishielectric fx5uj-24mt\/ess -
mitsubishielectric fx5uj-40mr\/es_firmware 1.000
mitsubishielectric fx5uj-40mr\/es -
mitsubishielectric fx5uj-40mt\/es_firmware 1.000
mitsubishielectric fx5uj-40mt\/es -
mitsubishielectric fx5uj-40mt\/ess_firmware 1.000
mitsubishielectric fx5uj-40mt\/ess -
mitsubishielectric fx5uj-60mr\/es_firmware 1.000
mitsubishielectric fx5uj-60mr\/es -
mitsubishielectric fx5uj-60mt\/es_firmware 1.000
mitsubishielectric fx5uj-60mt\/es -
mitsubishielectric fx5uj-60mt\/ess_firmware 1.000
mitsubishielectric fx5uj-60mt\/ess -
mitsubishielectric fx5-enet_firmware *
mitsubishielectric fx5-enet -
mitsubishielectric fx5-enet\/ip_firmware *
mitsubishielectric fx5-enet\/ip -
mitsubishielectric fx5-enet-adp_firmware *
mitsubishielectric fx5-enet-adp -
mitsubishielectric fx3g-14mr\/es_firmware *
mitsubishielectric fx3g-14mr\/es -
mitsubishielectric fx3g-14mt\/ess_firmware *
mitsubishielectric fx3g-14mt\/ess -
mitsubishielectric fx3g-14mr\/ds_firmware *
mitsubishielectric fx3g-14mr\/ds -
mitsubishielectric fx3g-14mt\/dss_firmware *
mitsubishielectric fx3g-14mt\/dss -
mitsubishielectric fx3g-24mr\/es_firmware *
mitsubishielectric fx3g-24mr\/es -
mitsubishielectric fx3g-24mt\/ess_firmware *
mitsubishielectric fx3g-24mt\/ess -
mitsubishielectric fx3g-24mr\/ds_firmware *
mitsubishielectric fx3g-24mr\/ds -
mitsubishielectric fx3g-24mt\/dss_firmware *
mitsubishielectric fx3g-24mt\/dss -
mitsubishielectric fx3g-40mr\/es_firmware *
mitsubishielectric fx3g-40mr\/es -
mitsubishielectric fx3g-40mt\/ess_firmware *
mitsubishielectric fx3g-40mt\/ess -
mitsubishielectric fx3g-40mr\/ds_firmware *
mitsubishielectric fx3g-40mr\/ds -
mitsubishielectric fx3g-40mt\/dss_firmware *
mitsubishielectric fx3g-40mt\/dss -
mitsubishielectric fx3g-60mr\/es_firmware *
mitsubishielectric fx3g-60mr\/es -
mitsubishielectric fx3g-60mt\/ess_firmware *
mitsubishielectric fx3g-60mt\/ess -
mitsubishielectric fx3g-60mr\/ds_firmware *
mitsubishielectric fx3g-60mr\/ds -
mitsubishielectric fx3g-60mt\/dss_firmware *
mitsubishielectric fx3g-60mt\/dss -
mitsubishielectric fx3g-24mr\/es_firmware *
mitsubishielectric fx3g-24mr\/es -
mitsubishielectric fx3g-24mt\/ess_firmware *
mitsubishielectric fx3g-24mt\/ess -
mitsubishielectric fx3g-24mr\/ds_firmware *
mitsubishielectric fx3g-24mr\/ds -
mitsubishielectric fx3g-24mt\/dss_firmware *
mitsubishielectric fx3g-24mt\/dss -
mitsubishielectric fx3g-40mr\/es_firmware *
mitsubishielectric fx3g-40mr\/es -
mitsubishielectric fx3g-40mt\/ess_firmware *
mitsubishielectric fx3g-40mt\/ess -
mitsubishielectric fx3g-40mr\/ds_firmware *
mitsubishielectric fx3g-40mr\/ds -
mitsubishielectric fx3g-40mt\/dss_firmware *
mitsubishielectric fx3g-40mt\/dss -
mitsubishielectric fx3g-32_mt\/dss_firmware *
mitsubishielectric fx3g-32_mt\/dss -
mitsubishielectric fx3u-enet_firmware *
mitsubishielectric fx3u-enet -
mitsubishielectric fx3u-enet-l_firmware *
mitsubishielectric fx3u-enet-l -
mitsubishielectric fx3u-enet-p502_firmware *
mitsubishielectric fx3u-enet-p502 -
mitsubishielectric fx5-cclgn-ms_firmware *
mitsubishielectric fx5-cclgn-ms -
mitsubishielectric iu1-1m20-d_firmware *
mitsubishielectric iu1-1m20-d -
mitsubishielectric le7-40gu-l_firmware *
mitsubishielectric le7-40gu-l -
mitsubishielectric got2000_series_gt21_firmware *
mitsubishielectric got2000_series_gt21 -
mitsubishielectric got_simple_series_gs21_firmware *
mitsubishielectric got_simple_series_gs21 -
mitsubishielectric got1000_series_gt14_firmware *
mitsubishielectric got1000_series_gt14 -
mitsubishielectric gt25-j71gn13-t2_firmware *
mitsubishielectric gt25-j71gn13-t2 -
mitsubishielectric fr-a820-e_firmware *
mitsubishielectric fr-a820-e -
mitsubishielectric fr-a840-e_firmware *
mitsubishielectric fr-a840-e -
mitsubishielectric fr-a860-e_firmware *
mitsubishielectric fr-a860-e -
mitsubishielectric fr-a842-e_firmware *
mitsubishielectric fr-a842-e -
mitsubishielectric fr-a862-e_firmware *
mitsubishielectric fr-a862-e -
mitsubishielectric fr-f820-e_firmware *
mitsubishielectric fr-f820-e -
mitsubishielectric fr-f840-e_firmware *
mitsubishielectric fr-f840-e -
mitsubishielectric fr-f860-e_firmware *
mitsubishielectric fr-f860-e -
mitsubishielectric fr-f842-e_firmware *
mitsubishielectric fr-f842-e -
mitsubishielectric fr-f862-e_firmware *
mitsubishielectric fr-f862-e -
mitsubishielectric fr-a8ncge_firmware *
mitsubishielectric fr-a8ncge -
mitsubishielectric fr-e800-epa_firmware *
mitsubishielectric fr-e800-epa -
mitsubishielectric fr-e800-epb_firmware *
mitsubishielectric fr-e800-epb -
mitsubishielectric conveyor_tracking_application_apr-ntr12fh -
mitsubishielectric conveyor_tracking_application_apr-ntr20fh\(n\=1\,2\) -
mitsubishielectric conveyor_tracking_application_apr-ntr3fh *
mitsubishielectric conveyor_tracking_application_apr-ntr6fh -
mitsubishielectric mr-je-c_firmware *
mitsubishielectric mr-je-c -
mitsubishielectric mr-j4-tm_firmware *
mitsubishielectric mr-j4-tm -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:qj71mes96_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D3C7DBDF-F467-4310-8B65-EF611692202F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:qj71mes96:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7E9566C3-CFB4-4658-AFAE-ADD1B9DA9211",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:qj71ws96_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F4AB29EE-605F-4140-A84F-B82E7762D826",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:qj71ws96:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E39BAAFF-FF1F-4279-B501-E0A918CC54CD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:q06ccpu-v_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9ED3CA2D-EE3F-4281-883F-4A7FCB4CEE3B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:q06ccpu-v:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E517BA2F-CF39-49C2-A68E-64A2CE17DBDE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:q24dhccpu-v_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3E848004-A141-4C9F-9A6C-73A3BD7A6082",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:q24dhccpu-v:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "210A2E8A-BF20-43F5-BA07-CB662833DE1D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:q24dhccpu-vg_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0D1FC6B1-F265-4565-95A7-1F3F55634C17",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:q24dhccpu-vg:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D9DF6F77-EEB5-4CB3-B041-7BA43F16E2E3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:r12ccpu-v_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "56BCED50-FEC2-4F26-81AC-0C3C9BD12C4B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:r12ccpu-v:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B938943-DDD5-43DC-98A3-29D0E6AFBF85",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:rd55up06-v_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EF1853A1-8C0D-4EC0-BECC-A89D1CEFDFE5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:rd55up06-v:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F1F5EF13-A273-459E-815B-F21C57D44204",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:rd55up12-v_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8E5CCD36-42A4-4B7C-B5E1-23F6E4BB1DAE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:rd55up12-v:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0ED862A7-87F7-4548-B2AB-2A3DB3ED1482",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:rj71gn11-t2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B3F3EDD1-A50F-4581-96D7-9577F9836574",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:rj71gn11-t2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A7B5FE39-4540-4A95-ABA8-15F8EA545DE1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:rj71en71_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B038D8DD-BE83-4AEB-96DF-FAF9EA630222",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:rj71en71:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8BD2CE10-A6DB-4642-8FA8-DD1AFA726EC7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:qj71e71-100_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4BAF2D41-713E-4EA6-A705-57963DBF1309",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:qj71e71-100:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6FD1EB30-B1FC-49CC-97D7-739AA5E92E86",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:lj71e71-100_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CFBF46E0-7580-48ED-AB04-490204FBBA33",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:lj71e71-100:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DF312DE0-1882-41A2-A2F6-BA4CB71837E2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:qj71mt91_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1BC6EE26-1644-45F7-8489-B6380FC493F4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:qj71mt91:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "58095D28-F44C-4876-9B6F-6D1CFD3D602A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:rd78gn\\(n\\=4\\,8\\,16\\,32\\,64\\)_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D8B55521-A137-4A7F-839E-1B3DBCB7E313",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:rd78gn\\(n\\=4\\,8\\,16\\,32\\,64\\):-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE041A8C-11A7-4FAB-A363-49F429AEF24A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:rd78ghv_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A5DCA431-9DA7-48B5-9107-86CA9DAD360E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:rd78ghv:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "12E5533D-15A8-471B-899B-FE9F9655EE8F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:rd78ghw_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B9722D1-BAB9-4E43-8612-4B6496DD1AF1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:rd78ghw:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B5C3119-7579-4623-8513-65A281BDF0D1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:nz2gacp620-60_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B5A3B553-08E8-4415-BDAF-897181D5B11A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:nz2gacp620-60:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFB0F4E4-F634-4D0C-A693-AC48962C320B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:nz2gacp620-300_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E791C3F4-D449-4B3B-B07D-A683D621B6A9",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:nz2gacp620-300:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "ABDD7EA6-1946-46DB-AD2B-2F778AB11AA3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:nz2ft-mt_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "071EB002-B837-48B0-8276-A8B0AA5D578E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:nz2ft-mt:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "713AE73B-463A-4B2B-8B35-64FB0D53B416",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:nz2ft-eip_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "40F04BC6-17EA-4F6F-BB5B-C87FEE3CB59B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:nz2ft-eip:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D5CF34B6-9CCF-491C-A327-A38D0BAC504D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:q03udecpu_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "37E5D21A-8561-45FE-88E1-725D3488AA22",
              "versionEndIncluding": "22081",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:q03udecpu:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "946DA26E-A6B2-46F6-BA81-A92133124823",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:qnudehcpu\\(n\\=04\\/06\\/10\\/13\\/20\\/26\\/50\\/100\\)_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "503A8334-5C68-440E-B76D-5B834557C999",
              "versionEndIncluding": "22081",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:qnudehcpu\\(n\\=04\\/06\\/10\\/13\\/20\\/26\\/50\\/100\\):-:*:*:*:*:*:*:*",
              "matchCriteriaId": "94A82925-8D77-4914-924A-350CF77857A4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:qnudvcpu\\(n\\=03\\/04\\/06\\/13\\/26\\)_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "57284400-F051-4E3A-B019-B308EF4F4997",
              "versionEndIncluding": "22031",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:qnudvcpu\\(n\\=03\\/04\\/06\\/13\\/26\\):-:*:*:*:*:*:*:*",
              "matchCriteriaId": "745BC528-D8A3-4393-A267-0A4E2FB81603",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:qnudpvcpu\\(n\\=04\\/06\\/13\\/2\\)_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F9EE5B71-EEAB-47E4-BCAB-1E81C40686B5",
              "versionEndIncluding": "22031",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:qnudpvcpu\\(n\\=04\\/06\\/13\\/2\\):-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6136D778-C9AB-49C2-A90C-9281B34308EA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:lncpu\\(-p\\)\\(n\\=02\\/06\\/26\\)_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2ACB71CE-71B7-442C-A44F-B9DF138C45F7",
              "versionEndIncluding": "22051",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:lncpu\\(-p\\)\\(n\\=02\\/06\\/26\\):-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1CC9C7BE-9D93-477D-B560-EAB4367A4844",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:l26cpu-\\(p\\)bt_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9FBAF171-F382-4393-A326-D43D8F8BB55B",
              "versionEndIncluding": "22051",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:l26cpu-\\(p\\)bt:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CE019E69-01F5-4AC8-BE72-48A7B0FD0C56",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:rncpu\\(n\\=00\\/01\\/02\\)t_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0D83880E-6DBE-4D64-B467-744F89C42743",
              "versionEndIncluding": "18",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:rncpu\\(n\\=00\\/01\\/02\\)t:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F8E83D77-A204-406C-AC54-CB97A66090C8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:rncpu\\(n\\=04\\/08\\/16\\/32\\/120\\)_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A4AF8ADC-ED05-43D2-AF6D-868737E4D1A8",
              "versionEndIncluding": "50",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:rncpu\\(n\\=04\\/08\\/16\\/32\\/120\\):-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0B2EE57C-3023-4071-BE28-8B42BD181EA1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:rnencpu\\(n\\=04\\/08\\/16\\/32\\/120\\)_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6937B45E-B23C-4DE1-A926-3529B4154A03",
              "versionEndIncluding": "50",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:rnencpu\\(n\\=04\\/08\\/16\\/32\\/120\\):-:*:*:*:*:*:*:*",
              "matchCriteriaId": "48C947EF-B119-440B-A47A-0B84A0087D30",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:rnsfcpu_\\(n\\=08\\/16\\/32\\/120\\)_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F7ABBACF-10F8-4729-8D3A-A9C5BDB961A5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:rnsfcpu_\\(n\\=08\\/16\\/32\\/120\\):-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C5CDD376-A0AD-4924-89F1-F04EBCA9C020",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:rnpcpu\\(n\\=08\\/16\\/32\\/120\\)_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E575079C-E69B-4A10-86F4-3440F9BAEBCE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:rnpcpu\\(n\\=08\\/16\\/32\\/120\\):-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1A5ABD37-C45D-4D7E-A93B-F9EA2544BA9B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:rnpsfcpu\\(n\\=08\\/16\\/32\\/120\\)_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B4B6D8B2-6E4F-437D-95A4-A24BFBFF7350",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:rnpsfcpu\\(n\\=08\\/16\\/32\\/120\\):-:*:*:*:*:*:*:*",
              "matchCriteriaId": "586B69F2-7276-437F-A69C-30B26ECB6B18",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5uc-32mt\\/d_firmware:1.210:*:*:*:*:*:*:*",
              "matchCriteriaId": "F319764C-436E-4B29-9224-4A9BFAB21A7B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5uc-32mt\\/d:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EBBFA917-5DCF-4B0C-8C32-AC384FB880AC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5uc-32mt\\/dss_firmware:1.210:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F895CD0-E081-49AB-84F9-B5F7C60921A5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5uc-32mt\\/dss:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2CFE160B-32CC-4529-AD35-7467A32B609E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5uc-32mt\\/ds-ts_firmware:1.210:*:*:*:*:*:*:*",
              "matchCriteriaId": "616147FF-B8C0-45DA-B398-B0C15C44BAAE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5uc-32mt\\/ds-ts:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C4B64FFA-59CE-46E9-B240-F083B332BFD1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5uc-32mt\\/dss-ts_firmware:1.210:*:*:*:*:*:*:*",
              "matchCriteriaId": "BD5D4DAB-0262-4D99-8164-1BF5FC36B8B9",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5uc-32mt\\/dss-ts:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2122A970-5A7D-40A6-BB97-622B695713ED",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5uj-24mr\\/es_firmware:1.000:*:*:*:*:*:*:*",
              "matchCriteriaId": "BBE714C4-7121-43BD-894B-274F25F01BF6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5uj-24mr\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F4BA009-4F0A-427C-9D4A-F8A128F5F8C9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5uc-32mr\\/ds-ts_firmware:1.210:*:*:*:*:*:*:*",
              "matchCriteriaId": "B7A24D5B-FE5C-4263-A313-0EE0A6B13E41",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5uc-32mr\\/ds-ts:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6319D639-CC7B-414E-9DCB-F9D427E8FEF2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5uj-24mt\\/es_firmware:1.000:*:*:*:*:*:*:*",
              "matchCriteriaId": "78F21B67-1550-4575-A6ED-342903CDB8D8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5uj-24mt\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2B284B91-7571-4614-A721-676D1972E2D0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5uj-24mt\\/ess_firmware:1.000:*:*:*:*:*:*:*",
              "matchCriteriaId": "653A0628-9267-4C71-AB2C-D89107171D37",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5uj-24mt\\/ess:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7D8A69D9-DE42-4953-AD81-40EF7A003823",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5uj-40mr\\/es_firmware:1.000:*:*:*:*:*:*:*",
              "matchCriteriaId": "8A5F3391-4B93-442F-857E-2B8717E93360",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5uj-40mr\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3B0AA6C3-68CC-454B-A959-707BB20F4E07",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5uj-40mt\\/es_firmware:1.000:*:*:*:*:*:*:*",
              "matchCriteriaId": "4C0617ED-28FF-4D7A-B246-F23292699021",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5uj-40mt\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8ED5C2F9-C203-40FD-B15C-F91A68FA0DCC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5uj-40mt\\/ess_firmware:1.000:*:*:*:*:*:*:*",
              "matchCriteriaId": "1A895C09-2DD4-451F-85A2-A77AE1CA36EE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5uj-40mt\\/ess:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1A38E527-6290-49AE-885A-21C4FC77EE96",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5uj-60mr\\/es_firmware:1.000:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A4B25D0-D814-42F5-A91A-A7DFF9D6E1ED",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5uj-60mr\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8CAF8ED8-B265-4FC5-91AE-CFA4C282E27F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5uj-60mt\\/es_firmware:1.000:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C56BC76-12CB-4B1C-A3D1-004DD311110B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5uj-60mt\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8F5B2760-4E56-4FAA-A723-BB7CC28FAFD2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5uj-60mt\\/ess_firmware:1.000:*:*:*:*:*:*:*",
              "matchCriteriaId": "B9705681-362F-4F8E-BC42-884A58C3A042",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5uj-60mt\\/ess:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7625B11E-0A91-46D2-8952-AC0BA956D7A8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5-enet_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0B1AC602-30AB-461B-A2BF-5310A33C36F0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5-enet:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1050809B-A058-451E-A62B-2E1707B3887E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5-enet\\/ip_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F30B0C7E-D11C-4BD8-A864-E6614DC79B0C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5-enet\\/ip:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EF5786BC-2E60-45A5-AD11-21CCAAFDDAAB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5-enet-adp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "86E3E631-A5CB-48EF-ACDF-5D936E20E517",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5-enet-adp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A5DA247C-6A4B-4813-BABE-9420919C69EE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-14mr\\/es_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD5F9558-9BE3-4798-8676-0D547240FF8C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-14mr\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7FDA7E6C-BFBF-4D78-8552-B2B3E6D9987B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-14mt\\/ess_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4F009EDE-0541-4E03-964D-8729DFEC2D4B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-14mt\\/ess:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F172545-1962-4611-AF12-C626B0F765FA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-14mr\\/ds_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9CE77F12-BB13-4E48-B047-4725B89544FB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-14mr\\/ds:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5766FC7F-312E-466E-9D1D-2C3D834A2B19",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-14mt\\/dss_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0E250D61-D30E-4902-9A3E-C964E3972998",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-14mt\\/dss:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8BC58D73-605B-4656-A93F-015178A11776",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-24mr\\/es_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E7E0F199-6BF9-469E-8531-F5855F4CAC0B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-24mr\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A13FA80E-2FCE-43EE-A5F9-01847762DE05",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-24mt\\/ess_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "71C5D511-C2FB-48D6-9546-D20C8320098F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-24mt\\/ess:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B6709317-170A-4146-8D34-8A36BB46CAB8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-24mr\\/ds_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C46851F9-1EE9-409A-8651-87B3A37F2C8C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-24mr\\/ds:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FA061AF-EC9E-4490-98B0-4397271B6AFD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-24mt\\/dss_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "79D96213-DF83-4985-BB51-B4ED181B338A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-24mt\\/dss:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E1374CFE-25E0-4357-B880-9C52BEE2219C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-40mr\\/es_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "ED616F78-DAAD-4F67-BEBE-3A14D6002650",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-40mr\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4EEA4C4A-0191-4A2C-B56F-E70475910A03",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-40mt\\/ess_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5940C5A4-254F-4BBC-A65F-A7B07B61B1C1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-40mt\\/ess:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B69421D2-A453-43A8-A8D8-5E0B73F7B24A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-40mr\\/ds_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "19D5F69E-3AB7-434A-9476-11A2D5C4C54C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-40mr\\/ds:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0BBBBCC7-AC22-49C0-B0C0-8D89E633AB74",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-40mt\\/dss_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "506ACCE1-28D0-4983-89F2-DC969D6C5EC8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-40mt\\/dss:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "24E0AE74-DF57-4461-9A91-11F31459EC68",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-60mr\\/es_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C7D2DA26-04D4-41AC-A00B-EE87780235B4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-60mr\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5CBC7773-96DA-433A-ABB8-845B19168EBF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-60mt\\/ess_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "50FCB926-E9C4-49F1-B657-F7E009EEE307",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-60mt\\/ess:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "010DBD73-40FF-4353-9D11-CE81C4D14EDB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-60mr\\/ds_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3E6CECFB-40F8-4B99-AF07-1FE874B7565C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-60mr\\/ds:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DB590D55-DA7F-4543-99AA-1A1979F73E69",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-60mt\\/dss_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8F7A4438-C9CB-46BB-B1ED-FE6069497A52",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-60mt\\/dss:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B69A0E1-E9FA-4C5C-810F-8D3CEC959C20",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-24mr\\/es_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E7E0F199-6BF9-469E-8531-F5855F4CAC0B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-24mr\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A13FA80E-2FCE-43EE-A5F9-01847762DE05",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-24mt\\/ess_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "71C5D511-C2FB-48D6-9546-D20C8320098F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-24mt\\/ess:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B6709317-170A-4146-8D34-8A36BB46CAB8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-24mr\\/ds_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C46851F9-1EE9-409A-8651-87B3A37F2C8C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-24mr\\/ds:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FA061AF-EC9E-4490-98B0-4397271B6AFD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-24mt\\/dss_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "79D96213-DF83-4985-BB51-B4ED181B338A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-24mt\\/dss:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E1374CFE-25E0-4357-B880-9C52BEE2219C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-40mr\\/es_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "ED616F78-DAAD-4F67-BEBE-3A14D6002650",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-40mr\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4EEA4C4A-0191-4A2C-B56F-E70475910A03",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-40mt\\/ess_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5940C5A4-254F-4BBC-A65F-A7B07B61B1C1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-40mt\\/ess:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B69421D2-A453-43A8-A8D8-5E0B73F7B24A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-40mr\\/ds_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "19D5F69E-3AB7-434A-9476-11A2D5C4C54C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-40mr\\/ds:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0BBBBCC7-AC22-49C0-B0C0-8D89E633AB74",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-40mt\\/dss_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "506ACCE1-28D0-4983-89F2-DC969D6C5EC8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-40mt\\/dss:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "24E0AE74-DF57-4461-9A91-11F31459EC68",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-32_mt\\/dss_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "43F233A3-B233-4112-93AA-6EA6638CBB77",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-32_mt\\/dss:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "16193E36-7987-45EB-AFBE-AFB360043E67",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-enet_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "686B0F97-14C8-48A6-A25F-DF3BC6A0DA07",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-enet:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5D1644E1-F748-46A3-8E09-FF5D53FD046F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-enet-l_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6A00A164-30D7-45BF-8CB4-00F18569F488",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-enet-l:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C8ACC832-E1EC-46DA-A2D1-CF1A3791A885",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-enet-p502_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0044A99C-4DAD-4593-B329-C3FFE706F8A8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-enet-p502:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "69BA96DC-C462-4286-AE0E-32D141017E7F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx5-cclgn-ms_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "671454B2-0474-479F-9F1E-EFCFAC01882E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx5-cclgn-ms:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0EE1B348-9F41-40EC-B1FC-D5919F332815",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:iu1-1m20-d_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "714615F1-05A9-4D62-8671-F76CD1380C5A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:iu1-1m20-d:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "680B7B83-9F76-4C1F-B87A-F7049A0C46E4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:le7-40gu-l_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0E4FD707-55B1-4A9C-9528-694C1008316B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:le7-40gu-l:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "41477864-1A55-4547-936A-29D6504F0D3A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:got2000_series_gt21_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "16EAF851-CD95-4DD7-9BA0-FBBE90F7339E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:got2000_series_gt21:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0873DFF7-9627-482D-A4A9-72F8E26ACBB0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:got_simple_series_gs21_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1F5BF7B0-75CE-481B-88E3-248D47CC19F2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:got_simple_series_gs21:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4D30700D-F1DC-46B1-8785-7E24721264D5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:got1000_series_gt14_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6D68C2E9-3D0A-466B-9476-BE8110EC27E4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:got1000_series_gt14:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D3BD1AB4-3A3D-46CD-B613-3E3613AAA273",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:gt25-j71gn13-t2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "44078605-B592-48CC-9F91-F1B745212D78",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:gt25-j71gn13-t2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BDCE2B83-0CBA-447A-8616-780301853AC0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fr-a820-e_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A70F1DC9-4930-4A99-BAC7-20F391693641",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fr-a820-e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "64F6D4E4-CFC1-4CD4-92B9-738A062612D5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fr-a840-e_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "689C466A-5CA6-4413-8BD6-CCFDBABC006A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fr-a840-e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CD00D598-4BEA-4E9B-9558-E80E22683C2C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fr-a860-e_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8AC34BC7-C4E4-4D3B-BAD8-8A77F44AF205",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fr-a860-e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "75275274-2442-4372-B0DD-8AB50ABF08D0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fr-a842-e_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D3F579C-C934-4589-90C2-FA1132104726",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fr-a842-e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1615F6C9-3C1E-47F0-9B61-607DCBAE7B50",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fr-a862-e_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AE896C56-DBD2-4050-9AB0-757F52FE0DBA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fr-a862-e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "08BBF6C1-F3DC-4E07-91A8-82D99BCE7E68",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fr-f820-e_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3B923961-A068-4BE4-9C4C-D4F05A8E4A76",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fr-f820-e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "ECD15A99-5F0A-49B7-82E4-59B1F8ADD94F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fr-f840-e_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B451C55F-DCCC-4C26-BB79-CDBFB9261B9A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fr-f840-e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0CB7232B-97CB-4820-A418-2CFEF95CED04",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fr-f860-e_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2735CEBA-9D80-4068-80D4-C5E2B46EB20E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fr-f860-e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2DDDBB50-1EAF-47E1-9DF0-9BA9433F3D47",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fr-f842-e_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0FDBDB8D-4019-462E-9D5D-FE5BB57B2F13",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fr-f842-e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BAE513C7-3A83-4B34-A986-016F0AD5216C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fr-f862-e_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CFE7D90D-4E2D-4E62-83ED-CEEC9BC58378",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fr-f862-e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "287546A0-141B-4A76-9B04-6914FF31B1A5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fr-a8ncge_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F6DD95FF-BA97-45E9-86E5-A1ED73395759",
              "versionEndIncluding": "2020-08",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fr-a8ncge:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "99159924-7D0D-4E0D-A212-1B997A58B791",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fr-e800-epa_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DD834CCD-0D6A-4BA7-8CF1-CE3F358D80DD",
              "versionEndIncluding": "2020-07",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fr-e800-epa:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A3D9C957-5A2F-46EC-B82C-6C0A36EB4A3F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fr-e800-epb_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "753A00F4-4E1C-400D-969C-CB187DE76467",
              "versionEndIncluding": "2020-07",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fr-e800-epb:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A448590A-35B3-4DB5-AEE6-5EBAE325920F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:conveyor_tracking_application_apr-ntr12fh:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1A6D0905-EEF6-4386-BE37-C138A722D04E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:conveyor_tracking_application_apr-ntr20fh\\(n\\=1\\,2\\):-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F0AF6F96-A8F3-4F1C-8BF6-BFADE4ECC872",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:conveyor_tracking_application_apr-ntr3fh:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D72D7D59-109B-4DD5-A59F-2D93D97FD69A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:conveyor_tracking_application_apr-ntr6fh:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EF939B93-2A02-4879-943E-29FB45173F1A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:mr-je-c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "449AF664-6DF7-46D5-8508-CA59D7BD9661",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:mr-je-c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2C350628-57BA-4E37-A15D-0B19FBE423AC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:mr-j4-tm_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6C702434-90C9-47B2-B9EF-F9AFD847D8D2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:mr-j4-tm:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "98B10997-62CF-4512-ABB2-A679E77245AD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Multiple Mitsubishi Electric products are vulnerable to impersonations of a legitimate device by a malicious actor, which may allow an attacker to remotely execute arbitrary commands."
    },
    {
      "lang": "es",
      "value": "M\u00faltiples productos de Mitsubishi Electric, son vulnerables a suplantaciones de un dispositivo leg\u00edtimo por parte de un actor malicioso, lo que puede permitir a un atacante ejecutar comandos arbitrarios remotamente"
    }
  ],
  "id": "CVE-2020-16226",
  "lastModified": "2024-11-21T05:06:58.517",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 7.5,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2020-10-05T18:15:13.133",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-245-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-245-01"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-342"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2023-10-13 02:15
Modified
2024-11-21 08:35
Summary
Improper Authentication vulnerability in Mitsubishi Electric Corporation MELSEC-F Series main modules allows a remote unauthenticated attacker to obtain sequence programs from the product or write malicious sequence programs or improper data in the product without authentication by sending illegitimate messages.
Impacted products
Vendor Product Version
mitsubishielectric fx3g-14_mr\/ds_firmware -
mitsubishielectric fx3g-14_mr\/ds -
mitsubishielectric fx3g-14_mr\/es_firmware -
mitsubishielectric fx3g-14_mr\/es -
mitsubishielectric fx3g-14_mt\/ds_firmware -
mitsubishielectric fx3g-14_mt\/ds -
mitsubishielectric fx3g-14_mt\/dss_firmware -
mitsubishielectric fx3g-14_mt\/dss -
mitsubishielectric fx3g-14_mt\/es_firmware -
mitsubishielectric fx3g-14_mt\/es -
mitsubishielectric fx3g-14_mt\/ess_firmware -
mitsubishielectric fx3g-14_mt\/ess -
mitsubishielectric fx3g-14mr\/ds_firmware -
mitsubishielectric fx3g-14mr\/ds -
mitsubishielectric fx3g-14mr\/es_firmware -
mitsubishielectric fx3g-14mr\/es -
mitsubishielectric fx3g-14mr\/es-a_firmware -
mitsubishielectric fx3g-14mr\/es-a -
mitsubishielectric fx3g-14mt\/ds_firmware -
mitsubishielectric fx3g-14mt\/ds -
mitsubishielectric fx3g-14mt\/dss_firmware -
mitsubishielectric fx3g-14mt\/dss -
mitsubishielectric fx3g-14mt\/es_firmware -
mitsubishielectric fx3g-14mt\/es -
mitsubishielectric fx3g-14mt\/es-a_firmware -
mitsubishielectric fx3g-14mt\/es-a -
mitsubishielectric fx3g-14mt\/ess_firmware -
mitsubishielectric fx3g-14mt\/ess -
mitsubishielectric fx3g-232adp\(-mb\)_firmware -
mitsubishielectric fx3g-232adp\(-mb\) -
mitsubishielectric fx3g-24_mr\/ds_firmware -
mitsubishielectric fx3g-24_mr\/ds -
mitsubishielectric fx3g-24_mr\/es_firmware -
mitsubishielectric fx3g-24_mr\/es -
mitsubishielectric fx3g-24_mt\/ds_firmware -
mitsubishielectric fx3g-24_mt\/ds -
mitsubishielectric fx3g-24_mt\/dss_firmware -
mitsubishielectric fx3g-24_mt\/dss -
mitsubishielectric fx3g-24_mt\/es_firmware -
mitsubishielectric fx3g-24_mt\/es -
mitsubishielectric fx3g-24_mt\/ess_firmware -
mitsubishielectric fx3g-24_mt\/ess -
mitsubishielectric fx3g-24mr\/ds_firmware -
mitsubishielectric fx3g-24mr\/ds -
mitsubishielectric fx3g-24mr\/es_firmware -
mitsubishielectric fx3g-24mr\/es -
mitsubishielectric fx3g-24mr\/es-a_firmware -
mitsubishielectric fx3g-24mr\/es-a -
mitsubishielectric fx3g-24mt\/ds_firmware -
mitsubishielectric fx3g-24mt\/ds -
mitsubishielectric fx3g-24mt\/dss_firmware -
mitsubishielectric fx3g-24mt\/dss -
mitsubishielectric fx3g-24mt\/es_firmware -
mitsubishielectric fx3g-24mt\/es -
mitsubishielectric fx3g-24mt\/es-a_firmware -
mitsubishielectric fx3g-24mt\/es-a -
mitsubishielectric fx3g-24mt\/ess_firmware -
mitsubishielectric fx3g-24mt\/ess -
mitsubishielectric fx3g-32_mt\/dss_firmware -
mitsubishielectric fx3g-32_mt\/dss -
mitsubishielectric fx3g-3a-adp_firmware -
mitsubishielectric fx3g-3a-adp -
mitsubishielectric fx3g-40_mr\/ds_firmware -
mitsubishielectric fx3g-40_mr\/ds -
mitsubishielectric fx3g-40_mr\/es_firmware -
mitsubishielectric fx3g-40_mr\/es -
mitsubishielectric fx3g-40_mt\/ds_firmware -
mitsubishielectric fx3g-40_mt\/ds -
mitsubishielectric fx3g-40_mt\/dss_firmware -
mitsubishielectric fx3g-40_mt\/dss -
mitsubishielectric fx3g-40_mt\/es_firmware -
mitsubishielectric fx3g-40_mt\/es -
mitsubishielectric fx3g-40_mt\/ess_firmware -
mitsubishielectric fx3g-40_mt\/ess -
mitsubishielectric fx3g-40mr\/ds_firmware -
mitsubishielectric fx3g-40mr\/ds -
mitsubishielectric fx3g-40mr\/es_firmware -
mitsubishielectric fx3g-40mr\/es -
mitsubishielectric fx3g-40mr\/es-a_firmware -
mitsubishielectric fx3g-40mr\/es-a -
mitsubishielectric fx3g-40mt\/ds_firmware -
mitsubishielectric fx3g-40mt\/ds -
mitsubishielectric fx3g-40mt\/dss_firmware -
mitsubishielectric fx3g-40mt\/dss -
mitsubishielectric fx3g-40mt\/es_firmware -
mitsubishielectric fx3g-40mt\/es -
mitsubishielectric fx3g-40mt\/es-a_firmware -
mitsubishielectric fx3g-40mt\/es-a -
mitsubishielectric fx3g-40mt\/ess_firmware -
mitsubishielectric fx3g-40mt\/ess -
mitsubishielectric fx3g-485adp\(-mb\)_firmware -
mitsubishielectric fx3g-485adp\(-mb\) -
mitsubishielectric fx3g-4ad-adp_firmware -
mitsubishielectric fx3g-4ad-adp -
mitsubishielectric fx3g-4ad-pt-adp_firmware -
mitsubishielectric fx3g-4ad-pt-adp -
mitsubishielectric fx3g-4ad-ptw-adp_firmware -
mitsubishielectric fx3g-4ad-ptw-adp -
mitsubishielectric fx3g-4ad-tc-adp_firmware -
mitsubishielectric fx3g-4ad-tc-adp -
mitsubishielectric fx3g-4da-adp_firmware -
mitsubishielectric fx3g-4da-adp -
mitsubishielectric fx3g-4da-pnk-adp_firmware -
mitsubishielectric fx3g-4da-pnk-adp -
mitsubishielectric fx3g-60_mr\/ds_firmware -
mitsubishielectric fx3g-60_mr\/ds -
mitsubishielectric fx3g-60_mr\/es_firmware -
mitsubishielectric fx3g-60_mr\/es -
mitsubishielectric fx3g-60_mt\/ds_firmware -
mitsubishielectric fx3g-60_mt\/ds -
mitsubishielectric fx3g-60_mt\/dss_firmware -
mitsubishielectric fx3g-60_mt\/dss -
mitsubishielectric fx3g-60_mt\/es_firmware -
mitsubishielectric fx3g-60_mt\/es -
mitsubishielectric fx3g-60_mt\/ess_firmware -
mitsubishielectric fx3g-60_mt\/ess -
mitsubishielectric fx3g-60mr\/ds_firmware -
mitsubishielectric fx3g-60mr\/ds -
mitsubishielectric fx3g-60mr\/es_firmware -
mitsubishielectric fx3g-60mr\/es -
mitsubishielectric fx3g-60mr\/es-a_firmware -
mitsubishielectric fx3g-60mr\/es-a -
mitsubishielectric fx3g-60mt\/ds_firmware -
mitsubishielectric fx3g-60mt\/ds -
mitsubishielectric fx3g-60mt\/dss_firmware -
mitsubishielectric fx3g-60mt\/dss -
mitsubishielectric fx3g-60mt\/es_firmware -
mitsubishielectric fx3g-60mt\/es -
mitsubishielectric fx3g-60mt\/es-a_firmware -
mitsubishielectric fx3g-60mt\/es-a -
mitsubishielectric fx3g-60mt\/ess_firmware -
mitsubishielectric fx3g-60mt\/ess -
mitsubishielectric fx3g-cnv-adp_firmware -
mitsubishielectric fx3g-cnv-adp -
mitsubishielectric fx3ga-24mr-cm_firmware -
mitsubishielectric fx3ga-24mr-cm -
mitsubishielectric fx3ga-24mt-cm_firmware -
mitsubishielectric fx3ga-24mt-cm -
mitsubishielectric fx3ga-40mr-cm_firmware -
mitsubishielectric fx3ga-40mr-cm -
mitsubishielectric fx3ga-40mt-cm_firmware -
mitsubishielectric fx3ga-40mt-cm -
mitsubishielectric fx3ga-60mr-cm_firmware -
mitsubishielectric fx3ga-60mr-cm -
mitsubishielectric fx3ga-60mt-cm_firmware -
mitsubishielectric fx3ga-60mt-cm -
mitsubishielectric fx3gc_firmware -
mitsubishielectric fx3gc -
mitsubishielectric fx3gc-32mt\/d_firmware -
mitsubishielectric fx3gc-32mt\/d -
mitsubishielectric fx3gc-32mt\/dss_firmware -
mitsubishielectric fx3gc-32mt\/dss -
mitsubishielectric fx3ge-24mr\/ds_firmware -
mitsubishielectric fx3ge-24mr\/ds -
mitsubishielectric fx3ge-24mr\/es_firmware -
mitsubishielectric fx3ge-24mr\/es -
mitsubishielectric fx3ge-24mt\/ds_firmware -
mitsubishielectric fx3ge-24mt\/ds -
mitsubishielectric fx3ge-24mt\/dss_firmware -
mitsubishielectric fx3ge-24mt\/dss -
mitsubishielectric fx3ge-24mt\/es_firmware -
mitsubishielectric fx3ge-24mt\/es -
mitsubishielectric fx3ge-24mt\/ess_firmware -
mitsubishielectric fx3ge-24mt\/ess -
mitsubishielectric fx3ge-40mr\/ds_firmware -
mitsubishielectric fx3ge-40mr\/ds -
mitsubishielectric fx3ge-40mr\/es_firmware -
mitsubishielectric fx3ge-40mr\/es -
mitsubishielectric fx3ge-40mt\/ds_firmware -
mitsubishielectric fx3ge-40mt\/ds -
mitsubishielectric fx3ge-40mt\/dss_firmware -
mitsubishielectric fx3ge-40mt\/dss -
mitsubishielectric fx3ge-40mt\/es_firmware -
mitsubishielectric fx3ge-40mt\/es -
mitsubishielectric fx3ge-40mt\/ess_firmware -
mitsubishielectric fx3ge-40mt\/ess -
mitsubishielectric fx3s-10mr\/ds_firmware -
mitsubishielectric fx3s-10mr\/ds -
mitsubishielectric fx3s-10mr\/es_firmware -
mitsubishielectric fx3s-10mr\/es -
mitsubishielectric fx3s-10mt\/ds_firmware -
mitsubishielectric fx3s-10mt\/ds -
mitsubishielectric fx3s-10mt\/dss_firmware -
mitsubishielectric fx3s-10mt\/dss -
mitsubishielectric fx3s-10mt\/es_firmware -
mitsubishielectric fx3s-10mt\/es -
mitsubishielectric fx3s-10mt\/ess_firmware -
mitsubishielectric fx3s-10mt\/ess -
mitsubishielectric fx3s-14mr\/ds_firmware -
mitsubishielectric fx3s-14mr\/ds -
mitsubishielectric fx3s-14mr\/es_firmware -
mitsubishielectric fx3s-14mr\/es -
mitsubishielectric fx3s-14mt\/ds_firmware -
mitsubishielectric fx3s-14mt\/ds -
mitsubishielectric fx3s-14mt\/dss_firmware -
mitsubishielectric fx3s-14mt\/dss -
mitsubishielectric fx3s-14mt\/es_firmware -
mitsubishielectric fx3s-14mt\/es -
mitsubishielectric fx3s-14mt\/ess_firmware -
mitsubishielectric fx3s-14mt\/ess -
mitsubishielectric fx3s-20mr\/ds_firmware -
mitsubishielectric fx3s-20mr\/ds -
mitsubishielectric fx3s-20mr\/es_firmware -
mitsubishielectric fx3s-20mr\/es -
mitsubishielectric fx3s-20mt\/ds_firmware -
mitsubishielectric fx3s-20mt\/ds -
mitsubishielectric fx3s-20mt\/dss_firmware -
mitsubishielectric fx3s-20mt\/dss -
mitsubishielectric fx3s-20mt\/es_firmware -
mitsubishielectric fx3s-20mt\/es -
mitsubishielectric fx3s-20mt\/ess_firmware -
mitsubishielectric fx3s-20mt\/ess -
mitsubishielectric fx3s-30mr\/ds_firmware -
mitsubishielectric fx3s-30mr\/ds -
mitsubishielectric fx3s-30mr\/es_firmware -
mitsubishielectric fx3s-30mr\/es -
mitsubishielectric fx3s-30mr\/es-2ad_firmware -
mitsubishielectric fx3s-30mr\/es-2ad -
mitsubishielectric fx3s-30mt\/ds_firmware -
mitsubishielectric fx3s-30mt\/ds -
mitsubishielectric fx3s-30mt\/dss_firmware -
mitsubishielectric fx3s-30mt\/dss -
mitsubishielectric fx3s-30mt\/es_firmware -
mitsubishielectric fx3s-30mt\/es -
mitsubishielectric fx3s-30mt\/es-2ad_firmware -
mitsubishielectric fx3s-30mt\/es-2ad -
mitsubishielectric fx3s-30mt\/ess_firmware -
mitsubishielectric fx3s-30mt\/ess -
mitsubishielectric fx3s-30mt\/ess-2ad_firmware -
mitsubishielectric fx3s-30mt\/ess-2ad -
mitsubishielectric fx3sa-10mr-cm_firmware -
mitsubishielectric fx3sa-10mr-cm -
mitsubishielectric fx3sa-10mt-cm_firmware -
mitsubishielectric fx3sa-10mt-cm -
mitsubishielectric fx3sa-14mr-cm_firmware -
mitsubishielectric fx3sa-14mr-cm -
mitsubishielectric fx3sa-14mt-cm_firmware -
mitsubishielectric fx3sa-14mt-cm -
mitsubishielectric fx3sa-20mr-cm_firmware -
mitsubishielectric fx3sa-20mr-cm -
mitsubishielectric fx3sa-20mt-cm_firmware -
mitsubishielectric fx3sa-20mt-cm -
mitsubishielectric fx3sa-30mr-cm_firmware -
mitsubishielectric fx3sa-30mr-cm -
mitsubishielectric fx3sa-30mt-cm_firmware -
mitsubishielectric fx3sa-30mt-cm -
mitsubishielectric fx3u-128mr\/es_firmware -
mitsubishielectric fx3u-128mr\/es -
mitsubishielectric fx3u-128mr\/es-a_firmware -
mitsubishielectric fx3u-128mr\/es-a -
mitsubishielectric fx3u-128mt\/es_firmware -
mitsubishielectric fx3u-128mt\/es -
mitsubishielectric fx3u-128mt\/es-a_firmware -
mitsubishielectric fx3u-128mt\/es-a -
mitsubishielectric fx3u-128mt\/ess_firmware -
mitsubishielectric fx3u-128mt\/ess -
mitsubishielectric fx3u-16mr\/ds_firmware -
mitsubishielectric fx3u-16mr\/ds -
mitsubishielectric fx3u-16mr\/es_firmware -
mitsubishielectric fx3u-16mr\/es -
mitsubishielectric fx3u-16mr\/es-a_firmware -
mitsubishielectric fx3u-16mr\/es-a -
mitsubishielectric fx3u-16mt\/ds_firmware -
mitsubishielectric fx3u-16mt\/ds -
mitsubishielectric fx3u-16mt\/dss_firmware -
mitsubishielectric fx3u-16mt\/dss -
mitsubishielectric fx3u-16mt\/es_firmware -
mitsubishielectric fx3u-16mt\/es -
mitsubishielectric fx3u-16mt\/es-a_firmware -
mitsubishielectric fx3u-16mt\/es-a -
mitsubishielectric fx3u-16mt\/ess_firmware -
mitsubishielectric fx3u-16mt\/ess -
mitsubishielectric fx3u-32mr\/ds_firmware -
mitsubishielectric fx3u-32mr\/ds -
mitsubishielectric fx3u-32mr\/es_firmware -
mitsubishielectric fx3u-32mr\/es -
mitsubishielectric fx3u-32mr\/es-a_firmware -
mitsubishielectric fx3u-32mr\/es-a -
mitsubishielectric fx3u-32mr\/ua1_firmware -
mitsubishielectric fx3u-32mr\/ua1 -
mitsubishielectric fx3u-32ms\/es_firmware -
mitsubishielectric fx3u-32ms\/es -
mitsubishielectric fx3u-32mt\/ds_firmware -
mitsubishielectric fx3u-32mt\/ds -
mitsubishielectric fx3u-32mt\/dss_firmware -
mitsubishielectric fx3u-32mt\/dss -
mitsubishielectric fx3u-32mt\/es_firmware -
mitsubishielectric fx3u-32mt\/es -
mitsubishielectric fx3u-32mt\/es-a_firmware -
mitsubishielectric fx3u-32mt\/es-a -
mitsubishielectric fx3u-32mt\/ess_firmware -
mitsubishielectric fx3u-32mt\/ess -
mitsubishielectric fx3u-48mr\/ds_firmware -
mitsubishielectric fx3u-48mr\/ds -
mitsubishielectric fx3u-48mr\/es_firmware -
mitsubishielectric fx3u-48mr\/es -
mitsubishielectric fx3u-48mr\/es-a_firmware -
mitsubishielectric fx3u-48mr\/es-a -
mitsubishielectric fx3u-48mt\/ds_firmware -
mitsubishielectric fx3u-48mt\/ds -
mitsubishielectric fx3u-48mt\/dss_firmware -
mitsubishielectric fx3u-48mt\/dss -
mitsubishielectric fx3u-48mt\/es_firmware -
mitsubishielectric fx3u-48mt\/es -
mitsubishielectric fx3u-48mt\/es-a_firmware -
mitsubishielectric fx3u-48mt\/es-a -
mitsubishielectric fx3u-48mt\/ess_firmware -
mitsubishielectric fx3u-48mt\/ess -
mitsubishielectric fx3u-64mr\/ds_firmware -
mitsubishielectric fx3u-64mr\/ds -
mitsubishielectric fx3u-64mr\/es_firmware -
mitsubishielectric fx3u-64mr\/es -
mitsubishielectric fx3u-64mr\/es-a_firmware -
mitsubishielectric fx3u-64mr\/es-a -
mitsubishielectric fx3u-64mr\/ua1_firmware -
mitsubishielectric fx3u-64mr\/ua1 -
mitsubishielectric fx3u-64ms\/es_firmware -
mitsubishielectric fx3u-64ms\/es -
mitsubishielectric fx3u-64mt\/ds_firmware -
mitsubishielectric fx3u-64mt\/ds -
mitsubishielectric fx3u-64mt\/dss_firmware -
mitsubishielectric fx3u-64mt\/dss -
mitsubishielectric fx3u-64mt\/es_firmware -
mitsubishielectric fx3u-64mt\/es -
mitsubishielectric fx3u-64mt\/es-a_firmware -
mitsubishielectric fx3u-64mt\/es-a -
mitsubishielectric fx3u-64mt\/ess_firmware -
mitsubishielectric fx3u-64mt\/ess -
mitsubishielectric fx3u-80mr\/ds_firmware -
mitsubishielectric fx3u-80mr\/ds -
mitsubishielectric fx3u-80mr\/es_firmware -
mitsubishielectric fx3u-80mr\/es -
mitsubishielectric fx3u-80mr\/es-a_firmware -
mitsubishielectric fx3u-80mr\/es-a -
mitsubishielectric fx3u-80mt\/ds_firmware -
mitsubishielectric fx3u-80mt\/ds -
mitsubishielectric fx3u-80mt\/dss_firmware -
mitsubishielectric fx3u-80mt\/dss -
mitsubishielectric fx3u-80mt\/es_firmware -
mitsubishielectric fx3u-80mt\/es -
mitsubishielectric fx3u-80mt\/es-a_firmware -
mitsubishielectric fx3u-80mt\/es-a -
mitsubishielectric fx3u-80mt\/ess_firmware -
mitsubishielectric fx3u-80mt\/ess -
mitsubishielectric fx3u-enet_firmware -
mitsubishielectric fx3u-enet -
mitsubishielectric fx3u-enet-l_firmware -
mitsubishielectric fx3u-enet-l -
mitsubishielectric fx3u-enet-p502_firmware -
mitsubishielectric fx3u-enet-p502 -
mitsubishielectric fx3uc_firmware -
mitsubishielectric fx3uc -
mitsubishielectric fx3uc-16mr\/d-t_firmware -
mitsubishielectric fx3uc-16mr\/d-t -
mitsubishielectric fx3uc-16mr\/ds-t_firmware -
mitsubishielectric fx3uc-16mr\/ds-t -
mitsubishielectric fx3uc-16mt\/d_firmware -
mitsubishielectric fx3uc-16mt\/d -
mitsubishielectric fx3uc-16mt\/d-p4_firmware -
mitsubishielectric fx3uc-16mt\/d-p4 -
mitsubishielectric fx3uc-16mt\/dss_firmware -
mitsubishielectric fx3uc-16mt\/dss -
mitsubishielectric fx3uc-16mt\/dss-p4_firmware -
mitsubishielectric fx3uc-16mt\/dss-p4 -
mitsubishielectric fx3uc-32mt-lt_firmware -
mitsubishielectric fx3uc-32mt-lt -
mitsubishielectric fx3uc-32mt-lt-2_firmware -
mitsubishielectric fx3uc-32mt-lt-2 -
mitsubishielectric fx3uc-32mt\/d_firmware -
mitsubishielectric fx3uc-32mt\/d -
mitsubishielectric fx3uc-32mt\/dss_firmware -
mitsubishielectric fx3uc-32mt\/dss -
mitsubishielectric fx3uc-64mt\/d_firmware -
mitsubishielectric fx3uc-64mt\/d -
mitsubishielectric fx3uc-64mt\/dss_firmware -
mitsubishielectric fx3uc-64mt\/dss -
mitsubishielectric fx3uc-96mt\/d_firmware -
mitsubishielectric fx3uc-96mt\/d -
mitsubishielectric fx3uc-96mt\/dss_firmware -
mitsubishielectric fx3uc-96mt\/dss -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-14_mr\\/ds_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E444A570-C7FD-4CCE-B2F3-CA83BF5164B9",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-14_mr\\/ds:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FEDEE8B5-CC21-4546-9773-D4F34B3951BF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-14_mr\\/es_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6795EA4E-191E-4A45-9675-4B2B8AC00785",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-14_mr\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "960F3E05-93CB-4785-9123-F9DC55CD167B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-14_mt\\/ds_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4981D649-6D01-4DD6-8601-6A7A3BDF4F8B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-14_mt\\/ds:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "782A7A4A-48C0-4E3D-AFAB-C9912B08CECD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-14_mt\\/dss_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9B0F45E5-0499-4078-9125-04B3144AE3D1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-14_mt\\/dss:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6148A382-A3D3-4EBE-AD6F-DBFAB54C23DD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-14_mt\\/es_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "38A9DCF8-929A-47FF-8169-6120C542B400",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-14_mt\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9AE272E8-5180-4C2C-A6FB-9813C7BA8786",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-14_mt\\/ess_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1B903CAE-464B-458F-AD63-2BC5708770DA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-14_mt\\/ess:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "813A7D21-ADE5-4E97-8FA7-DA4F1F18042F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-14mr\\/ds_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0AE0608D-908F-4702-9464-F3443D318E21",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-14mr\\/ds:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5766FC7F-312E-466E-9D1D-2C3D834A2B19",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-14mr\\/es_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A5F3736B-F4C5-48A7-B27B-6816E9413D19",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-14mr\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7FDA7E6C-BFBF-4D78-8552-B2B3E6D9987B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-14mr\\/es-a_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "80F706EE-51DC-47C4-9C47-BD3AED1169D8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-14mr\\/es-a:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "776C81B4-89BE-4E59-8EE4-4172F1C819EE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-14mt\\/ds_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B836C49-4CE0-47B9-90B8-46B37EB1C5CD",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-14mt\\/ds:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3EC7A6F2-0FAA-4D9C-8E32-4B630B6E0C1D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-14mt\\/dss_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0B1D9F99-9273-4990-9C5A-345B6D960894",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-14mt\\/dss:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8BC58D73-605B-4656-A93F-015178A11776",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-14mt\\/es_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A06675A-29C2-436C-ADD0-647523CAA2E3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-14mt\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "82C8038B-BA5E-4C3C-A9FA-7F4DF5FB4B90",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-14mt\\/es-a_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D6A2CA9-D8F4-47ED-9AC2-CEEB6F43A5A4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-14mt\\/es-a:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2F9B5AD3-9E2E-4CF8-BCC1-1DC1B9AFA84C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-14mt\\/ess_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6BA42524-07CF-4F84-8038-7AA68BF61A8C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-14mt\\/ess:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F172545-1962-4611-AF12-C626B0F765FA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-232adp\\(-mb\\)_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "87D2DF99-A998-469B-819E-C578FE5A0C0F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-232adp\\(-mb\\):-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3D16BD14-31FC-4BA9-9DC0-3ECC5A01879A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-24_mr\\/ds_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3D22F668-5706-4A0B-9063-588C8D278780",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-24_mr\\/ds:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7E65AF48-87D6-4633-80CE-E06D841731E2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-24_mr\\/es_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3AAE1DA0-127A-40A8-A59A-CC8753055315",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-24_mr\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F7B2E5E6-B5AE-4EEC-98CD-C09C2B3C1CEC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-24_mt\\/ds_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C16C6E43-DC7F-4C83-A0DB-89C21D326D2E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-24_mt\\/ds:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DAC68881-7BD4-4CCA-86EF-048119EDF2A1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-24_mt\\/dss_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F5BC763B-ACC9-4BB5-939A-876F8DC93F38",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-24_mt\\/dss:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1A7A0502-E034-4647-97F8-4BDD1FEA74B5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-24_mt\\/es_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B7A25EA8-0298-4408-B186-B52964885AFC",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-24_mt\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3BF48B94-B38E-44F8-8AD8-2813A2DA1E27",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-24_mt\\/ess_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "774CE6D5-730B-428D-822E-4ECAE3DF8D15",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-24_mt\\/ess:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "ED18005B-3ED7-457E-BD81-48BE04D22059",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-24mr\\/ds_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E186D9C7-0015-4F10-AF4A-5E2B0D808E92",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-24mr\\/ds:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FA061AF-EC9E-4490-98B0-4397271B6AFD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-24mr\\/es_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BD9EF0CD-CF20-44B4-AF85-36BB46B5C17A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-24mr\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A13FA80E-2FCE-43EE-A5F9-01847762DE05",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-24mr\\/es-a_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "907346DB-7343-472E-8F99-EABDFA5F7717",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-24mr\\/es-a:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7DEC5C39-9751-4AD0-A030-AA283DA25FE4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-24mt\\/ds_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D66F4099-33B9-4FB4-8FDB-2FCFCD029C41",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-24mt\\/ds:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "905E3D20-2E81-40CB-8BC5-0F2E99DB4F2C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-24mt\\/dss_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2A826B7E-7CED-4767-9CF1-3EF0B60064DE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-24mt\\/dss:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E1374CFE-25E0-4357-B880-9C52BEE2219C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-24mt\\/es_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E3EDF1CF-9726-42FD-A44D-3AAECC0CC739",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-24mt\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E02660FF-B5B1-47F7-8566-45EA3C86783F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-24mt\\/es-a_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B6C39385-5311-4CBB-A5A4-46CE5176989F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-24mt\\/es-a:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CF7530C6-5244-4591-8037-5EFD35F8AC34",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-24mt\\/ess_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8DEC4E0C-7D80-4BC2-A88E-00E35090FFB4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-24mt\\/ess:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B6709317-170A-4146-8D34-8A36BB46CAB8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-32_mt\\/dss_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8D757DCC-29ED-4E09-B309-5DD003952CFB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-32_mt\\/dss:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "16193E36-7987-45EB-AFBE-AFB360043E67",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-3a-adp_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "722B9083-7B72-4161-92BA-52849B189C91",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-3a-adp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EDA013EF-1BCA-4C3E-A15A-B7094A010F80",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-40_mr\\/ds_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F8641082-790F-4FCF-9051-E575C0EF706C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-40_mr\\/ds:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2C179D4C-9B03-4526-9F21-2581ECA017DB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-40_mr\\/es_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CFFF6B18-30CC-499E-8BCA-3D0CD10D433B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-40_mr\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "55A8C97A-8668-4BBA-8923-6004ECD19759",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-40_mt\\/ds_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E370BF36-CFA9-436B-9BF4-EF9E61599023",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-40_mt\\/ds:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7EF08660-73EE-4550-997D-F386F7F8441A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-40_mt\\/dss_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "89740455-D496-42A8-B06C-20F33B209C32",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-40_mt\\/dss:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AB07DCBB-3403-4496-9307-7826D918BB81",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-40_mt\\/es_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5ACAD1E7-AE78-479C-97AF-08F4C47C257D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-40_mt\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A4213FC4-861A-4214-A16B-E79E99B88E72",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-40_mt\\/ess_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A81E62D6-2902-4814-A1C0-C0262C56156E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-40_mt\\/ess:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9C15FE21-A180-4187-AF50-6B664A33CDE8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-40mr\\/ds_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "20A0297C-B80E-4B20-8D2D-EA76978E88D6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-40mr\\/ds:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0BBBBCC7-AC22-49C0-B0C0-8D89E633AB74",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-40mr\\/es_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "61DD79AB-6E10-451B-BAE2-120728459EF4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-40mr\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4EEA4C4A-0191-4A2C-B56F-E70475910A03",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-40mr\\/es-a_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A28CD4CC-7705-48F3-B160-FF240BDB7665",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-40mr\\/es-a:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F1C5D73F-A319-4922-B472-BCF5BBDC560D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-40mt\\/ds_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "89B3D140-E93A-49FD-8BDD-81DCA23062D5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-40mt\\/ds:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B0520F3B-FE0F-483C-9201-D916D333AC34",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-40mt\\/dss_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0F532869-CCD3-49CA-9CD8-11C389FD610E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-40mt\\/dss:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "24E0AE74-DF57-4461-9A91-11F31459EC68",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-40mt\\/es_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B2146C1E-2DC4-4839-AAF7-20EC5DAA72CC",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-40mt\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "90A1CA11-AC74-42B4-980B-ADFA6792F85B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-40mt\\/es-a_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "585E560C-B4DD-4355-BC98-2990897C7492",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-40mt\\/es-a:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DE85CAB9-A799-417C-B6C5-B1D2E0291194",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-40mt\\/ess_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "06574AD8-8F05-4140-BDD9-4DBD0155A8C3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-40mt\\/ess:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B69421D2-A453-43A8-A8D8-5E0B73F7B24A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-485adp\\(-mb\\)_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A49FA21A-A111-4B95-8383-42E9330015BA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-485adp\\(-mb\\):-:*:*:*:*:*:*:*",
              "matchCriteriaId": "434CCB2F-403A-4C40-8B3F-FFE47B6CE050",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-4ad-adp_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EF08287D-2952-4B2A-A31D-AEFB8D1580AF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-4ad-adp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3A0B94DF-17B6-443A-9BE4-0B72A474C794",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-4ad-pt-adp_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B3C42A0A-99D4-42CB-B576-CD535F4FE5F8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-4ad-pt-adp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3FAB2696-16C3-431A-B54A-0D879E363AD9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-4ad-ptw-adp_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FCD10930-4507-440B-8B08-E0A9819B396F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-4ad-ptw-adp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "278BEDD2-2F91-43FA-A9D7-3501C87F24E9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-4ad-tc-adp_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7352D643-90BE-42BD-94C8-5EAD014F1BDE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-4ad-tc-adp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7E87C1FA-F824-4F69-AE46-3B0273E887B4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-4da-adp_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B77879D7-664B-4098-98C4-9705EE5A443F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-4da-adp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D380C6B6-2B87-4279-9B8B-1BB6B64AD895",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-4da-pnk-adp_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8A740855-A401-4541-B292-984396CC73E3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-4da-pnk-adp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D1DA2A08-CFC5-4943-9C35-03A3E5C5AFFF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-60_mr\\/ds_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "78D13195-CE64-4165-B350-9E60426F8A81",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-60_mr\\/ds:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "21BE74EA-5D64-4DA5-B909-02BAF7545C5A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-60_mr\\/es_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "329149AD-0905-4335-AFB3-39B4A310F29B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-60_mr\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4D8B3758-2261-4CE4-BDDB-7B6C22F4D3D7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-60_mt\\/ds_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DEFC3E81-0F90-438E-8DB1-1D411BC42CD1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-60_mt\\/ds:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EAC9D3C4-8646-4B14-9984-D6BDF2F3BA16",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-60_mt\\/dss_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2CF15966-0F09-4029-8893-0B2B8D1A60C8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-60_mt\\/dss:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "30692B61-A4F7-4639-BE11-5D70593371DE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-60_mt\\/es_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6F3DFBC7-6842-401B-96BD-E82C626FEC52",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-60_mt\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FCC92E43-E9F9-4B85-A598-7A14F5443918",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-60_mt\\/ess_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2E5D547B-DAA8-4797-AA35-17E510F4AF57",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-60_mt\\/ess:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C3E249B8-0FA5-414E-ADA1-2A9322274FF5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-60mr\\/ds_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A3600241-6D05-4C63-8E3D-A56A5A702C9E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-60mr\\/ds:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DB590D55-DA7F-4543-99AA-1A1979F73E69",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-60mr\\/es_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "522706E5-D5D3-494D-9290-F9D025ABEBFB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-60mr\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5CBC7773-96DA-433A-ABB8-845B19168EBF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-60mr\\/es-a_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "97DACA77-5FC4-42F1-8D50-0B7A6E3042E1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-60mr\\/es-a:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B9EBFAEF-FCB8-4691-8CC8-DCA2AB1453B7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-60mt\\/ds_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE9EDD50-E7D6-437E-BBD3-3523CB0D87CB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-60mt\\/ds:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D05F5287-23A1-4EC3-8524-82A215E881D2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-60mt\\/dss_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7D0A5DBB-65E7-48AB-9C3C-6EF1CE2026C9",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-60mt\\/dss:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B69A0E1-E9FA-4C5C-810F-8D3CEC959C20",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-60mt\\/es_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8CEBA70C-C30D-43D1-AB88-09B2DE143C33",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-60mt\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "91E087A7-A9EA-4A10-AF7D-6B86D070C323",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-60mt\\/es-a_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "768117D2-E73E-4B88-8998-EDF7F3800433",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-60mt\\/es-a:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CEDE33F5-A390-4444-AA04-E419D6B7FCFE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-60mt\\/ess_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AE193F5C-0081-4A6E-856E-DB1DD47C6F73",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-60mt\\/ess:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "010DBD73-40FF-4353-9D11-CE81C4D14EDB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3g-cnv-adp_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E09E76A2-8B2F-4C86-8BAE-515B3DE7D4D8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3g-cnv-adp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "487E84CA-646E-483E-9582-34BFFD44F49E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3ga-24mr-cm_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BDE0E13F-028A-4D2C-A7BE-E90FBA8DFBD4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3ga-24mr-cm:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "02F36D61-366C-40F2-ABD1-A5ADB1D5758E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3ga-24mt-cm_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5B5D74EA-798D-4D5D-A431-098DD529EE99",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3ga-24mt-cm:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D6B2BF6D-50FC-45BA-8A75-B0207172F192",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3ga-40mr-cm_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DD82E0E9-E8E2-4F3A-AABE-A458971E8D57",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3ga-40mr-cm:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DAC7368C-4339-423E-ADFF-9C4AB902EA19",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3ga-40mt-cm_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4F50D3EE-F42F-48BF-B35F-E8E7FB810D93",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3ga-40mt-cm:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "825DFC3C-B1A8-460C-9A59-FDB2671C7152",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3ga-60mr-cm_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1C79E9FA-A5BF-4A5E-8202-388023D4C09B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3ga-60mr-cm:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "866AEC77-EEE5-45C8-9CB3-DA8B7773ED54",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3ga-60mt-cm_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7758736E-CC6F-4F6D-9888-A40C91AE47E1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3ga-60mt-cm:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7E9E9B4F-E217-455D-98F1-9EFEA12963AC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3gc_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6BF49EC6-DA86-475E-B67A-50E55F4849B2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3gc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D319713C-7222-429B-87E3-3C4BFCD23E85",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3gc-32mt\\/d_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FC2F8BAB-834B-43E1-8C53-9E9B75C5136A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3gc-32mt\\/d:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "49CAB744-E889-4860-9A9E-01FF265CE813",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3gc-32mt\\/dss_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9822843-FB60-4508-907D-D7BA28C078E2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3gc-32mt\\/dss:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6DEFD48F-EBB6-4B3F-AA8C-7F77073D6B27",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3ge-24mr\\/ds_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5D149F56-652A-4E69-AE2E-54C013C7E735",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3ge-24mr\\/ds:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "95F939C6-1FBC-4D2A-A0E0-A5C74170D71E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3ge-24mr\\/es_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "51C499F3-EF03-4F65-8B0B-87741CA3D055",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3ge-24mr\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D8C4F7E5-1871-4FBD-9AA5-3A13B76290C0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3ge-24mt\\/ds_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C97799B7-00AE-4EF2-9420-9FA2256523D5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3ge-24mt\\/ds:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D6FDF6C3-5995-4330-BFC8-D3F8DB807892",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3ge-24mt\\/dss_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "31ACE8B7-3C79-4BE8-850D-670EE389F26C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3ge-24mt\\/dss:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CF598729-B5F5-4808-BEF5-08CCD52D3BFD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3ge-24mt\\/es_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B504285D-C4B3-498D-A4CB-17D8DE142AD0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3ge-24mt\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E6F9F6E8-4673-442F-BCAF-7C77538ED742",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3ge-24mt\\/ess_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D6555546-9CB4-432B-85D2-A8EACFF3F4D7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3ge-24mt\\/ess:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "91263BE3-3F55-4D92-BF7B-FA3A9BC04752",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3ge-40mr\\/ds_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "56170D2E-7130-4210-8702-8699DC4C6D84",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3ge-40mr\\/ds:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB61263F-0E41-4A89-ACA0-174825775B75",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3ge-40mr\\/es_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "99C5E7CD-FC17-4501-88B6-8BD53507F836",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3ge-40mr\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "85C83082-0E9D-48E5-BD38-59A7EAAB463D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3ge-40mt\\/ds_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "357F433E-F2C1-4A95-88EC-0B9801FB8A5F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3ge-40mt\\/ds:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3041CDDC-2200-403C-9F4D-8BE9A0532774",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3ge-40mt\\/dss_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6D9F0592-94C2-41F9-A326-D8F3803F3771",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3ge-40mt\\/dss:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "90B5169A-9D3E-452D-85DB-204438181D6A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3ge-40mt\\/es_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9A8EB7A2-2159-4DDE-A8BD-BD3C4815EB2E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3ge-40mt\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "143C2ED9-FC12-45FF-9559-6E932AE9537D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3ge-40mt\\/ess_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7ED15018-C6D7-413A-91D5-66BCA22AF9D1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3ge-40mt\\/ess:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "079675D1-8C10-46C8-8723-E0B66717E8DD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3s-10mr\\/ds_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EB3B4C24-BE31-4358-9F60-045EF88CE1A6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3s-10mr\\/ds:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0A69B8D0-51D4-4EAD-B030-25AD01B25F71",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3s-10mr\\/es_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "61CCB838-A5DD-45CA-8422-F586A6C6AB3B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3s-10mr\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DE0DF245-3A50-4DC8-97F3-D60D79051999",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3s-10mt\\/ds_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "394AD4FC-2D14-46DE-AD36-B2721B54D08B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3s-10mt\\/ds:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "87A14A96-143B-48AE-9760-4330DF19738C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3s-10mt\\/dss_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8EABCC91-5A76-4E06-A036-9FF6B0E95029",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3s-10mt\\/dss:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9830EB7C-5F96-4DA8-A3D8-4140E8CD239E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3s-10mt\\/es_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AC113AB1-02CB-4B60-A21A-B58350705524",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3s-10mt\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "658E556E-CF4B-4FD9-9B85-03AD34410100",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3s-10mt\\/ess_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C05CCA0A-DF0C-4D68-A1B1-94B1EF756747",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3s-10mt\\/ess:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7BAA8E79-DE23-4906-A923-5A41124ED4B4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3s-14mr\\/ds_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0D86B991-7C59-4D50-B6AC-FEA10B740278",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3s-14mr\\/ds:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5248CFDC-7822-4A8F-8034-25A938984B20",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3s-14mr\\/es_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7B66842E-A440-4010-888F-F2E8787114AD",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3s-14mr\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E90528E5-FD72-4532-B42E-7242209F1DB3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3s-14mt\\/ds_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "577A1638-11DE-405B-8E66-41ED293A73CB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3s-14mt\\/ds:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "65EAF73D-36B6-436B-A68D-79EE187611DE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3s-14mt\\/dss_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "89EE194D-AD58-470F-A6D8-37F523399222",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3s-14mt\\/dss:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "46CE128F-21E8-4306-AE3F-9E30F1161E69",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3s-14mt\\/es_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D8383936-27DA-4393-905E-D5E220038650",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3s-14mt\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "92C0A39F-EC73-4A85-A443-2AD3B23B2369",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3s-14mt\\/ess_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "298E9588-BE31-4278-B016-EC5C8AABC954",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3s-14mt\\/ess:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "ABEA8FBE-EDA3-4A69-8E78-DC9E0BC12763",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3s-20mr\\/ds_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "15D09642-AF76-4ABE-AA3B-CFF9CD815372",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3s-20mr\\/ds:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F55E3A12-EBA0-4D7E-A679-0E0634E8F34A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3s-20mr\\/es_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B51E1D8D-E663-4037-8CF2-14CD2A1224E2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3s-20mr\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CE98DCF0-7956-47D7-AC69-2C5BF6FA8086",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3s-20mt\\/ds_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA430C19-0BB0-4698-996B-DBB27798DEDE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3s-20mt\\/ds:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "71918F77-D72F-4FC6-9428-ABC50B784264",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3s-20mt\\/dss_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1F69E6B2-BDF2-436D-B66F-E752F33E9CBF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3s-20mt\\/dss:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9BEC0A27-4672-49FC-9837-68A631FA1C7C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3s-20mt\\/es_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B19D1167-EB5B-448C-9EDF-F72888FE38DF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3s-20mt\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "35F61BD7-F0C2-46CD-8B18-FA65CDD4C56B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3s-20mt\\/ess_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D8A26A7-AD07-4D68-B761-44FC98F1EBC8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3s-20mt\\/ess:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "87AA0A29-E8FE-4742-B2C5-A30B07E8F2CF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3s-30mr\\/ds_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "12721492-592C-40C8-8E9E-359497D663B1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3s-30mr\\/ds:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "005999C7-8D89-48DA-9310-63840225655B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3s-30mr\\/es_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AFB98DC2-DA6C-4338-AFA2-5A9717052AFF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3s-30mr\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B8B29F71-8CDB-43E2-AC1F-F8789399E1B8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3s-30mr\\/es-2ad_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "18E97BA8-9B11-4E42-AC8D-D281533A75EF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3s-30mr\\/es-2ad:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "67FF96CF-4C97-4427-93FD-C896CE229413",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3s-30mt\\/ds_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "18F0B8C0-A283-4209-82E9-1481969F79D3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3s-30mt\\/ds:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "303C9B51-4DFB-49E4-A47C-56B500FAC873",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3s-30mt\\/dss_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1AF8636C-5FDF-4B40-B246-669903AF9237",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3s-30mt\\/dss:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0B21F82B-3B1D-4435-9EDA-B3375CF9DC9D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3s-30mt\\/es_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "964183F2-6F83-4350-9761-55F13E4F96BA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3s-30mt\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "90D58142-FD09-415B-B9F6-20E26B4EBBC0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3s-30mt\\/es-2ad_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5654863A-5D44-4563-B88C-1EA988C6103E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3s-30mt\\/es-2ad:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BCBAC3A8-AA45-47FF-AE92-A809D2492A67",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3s-30mt\\/ess_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "12D8451C-7F17-4A0A-A63A-E85BC50341EF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3s-30mt\\/ess:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DC29835F-4E7F-43A0-A2D0-6D322B2BFB88",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3s-30mt\\/ess-2ad_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0F6F3191-D86A-4A61-A04B-584CFEC6D082",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3s-30mt\\/ess-2ad:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3BF62084-562B-45F0-91EB-12CDD2304861",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3sa-10mr-cm_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1CF253F1-C89B-4F7A-9ED5-AB6E45384E3B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3sa-10mr-cm:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2039FFC8-2158-4104-BB6C-1F5B4223D362",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3sa-10mt-cm_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B84915B7-988C-4E9B-BA98-DDE669BCB747",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3sa-10mt-cm:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "027D7B3C-4D57-4B51-A097-4DB949AF5AA5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3sa-14mr-cm_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0174E0AF-D4AF-4D48-AD73-13D9E3601506",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3sa-14mr-cm:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DB752455-EB9F-4DDA-8096-F58461AA12CC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3sa-14mt-cm_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E70A4A8E-2C6A-4F69-8165-7D4D4D322479",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3sa-14mt-cm:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A24DD068-5721-4BCF-960F-630E70F3D54B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3sa-20mr-cm_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C1A1C66C-7895-4E4F-BB23-8517B37B66EB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3sa-20mr-cm:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F69DA3AB-EE88-4B75-B151-48E283B34B5D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3sa-20mt-cm_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D95886BA-4CE3-4933-9084-38650D0CE22A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3sa-20mt-cm:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "383C3ED4-3A11-4574-AD11-15E123705A8F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3sa-30mr-cm_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "039A1D95-EC4B-428B-B9A7-88AA89A08667",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3sa-30mr-cm:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B4D84A6F-0353-4534-B7E2-7F0DDE247EF4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3sa-30mt-cm_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "545F5DD4-EA85-408E-8756-99FE700EBD05",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3sa-30mt-cm:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8DD33CC9-DE0D-404B-9AD3-E9361F203AF8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-128mr\\/es_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7C30FB7E-3BCB-4A20-AD13-A36A051FC5D1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-128mr\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA7595AC-9CBD-4785-9005-5E0FAEC27D2C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-128mr\\/es-a_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BAEF478A-5D48-47C1-9B32-945DE0281DC6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-128mr\\/es-a:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "07B641ED-17C0-4383-9D45-6C63A38FB3E5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-128mt\\/es_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "138B4032-E9D4-4E85-8863-C334383A457E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-128mt\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "19DE07A9-7494-4C42-A452-57CF0573A3B3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-128mt\\/es-a_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "42CD66FA-074E-4567-A31C-C3243247C361",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-128mt\\/es-a:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E915604A-1C8A-409C-BFD8-A6414C1582E4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-128mt\\/ess_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7D6BBB82-E022-462F-BBCB-D36C2CC91FC6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-128mt\\/ess:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A60E2A0E-D686-470D-82E0-8C28F50E8CD0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-16mr\\/ds_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "04C64F82-7D74-4E36-95E0-4EF0077424F8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-16mr\\/ds:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2E9E219D-83B8-4C29-801E-9E3AA9BB87A1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-16mr\\/es_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "10D56C7D-7430-4E27-9AEC-7FE53ECEEAEB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-16mr\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F2A8CAFC-6AF5-4044-9E77-F9B8A0CF36BA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-16mr\\/es-a_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5E0C5307-FB3B-4639-B412-DDA54746B068",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-16mr\\/es-a:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6EC7B0BA-52F1-468E-8C79-033E0A46FE16",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-16mt\\/ds_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A46C02E6-FD3C-4E33-93A0-215AFF540AC5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-16mt\\/ds:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3A3CE75E-74E8-404B-9DB7-F0446262017E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-16mt\\/dss_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "66AE4031-A95C-4BCD-BD37-14F350403C8A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-16mt\\/dss:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E450F049-C2FB-494E-86C4-E434E13AAD6C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-16mt\\/es_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1550E8C5-8A19-4B7D-A455-42D073F239FC",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-16mt\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5387C911-2E14-45F6-9F8C-0892F2A5EBDE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-16mt\\/es-a_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6F884FF0-0CC5-4749-9F74-36814A1A9D24",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-16mt\\/es-a:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D7FE742D-0097-44EB-8297-3AA561A8E511",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-16mt\\/ess_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8BE5015A-87F2-4C3F-8794-292A98F75475",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-16mt\\/ess:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "709A855C-DCA6-4D18-84CC-440E14411FA5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-32mr\\/ds_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3749A776-2FA8-43FA-8678-F6B401CB2697",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-32mr\\/ds:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1334D6D4-DBBB-4A58-ACF5-AF77603F49FC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-32mr\\/es_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "796B9C41-112B-4BAC-BDF7-308967D4598F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-32mr\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DF43C36F-8FEB-4B72-AA44-371B54C6E35F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-32mr\\/es-a_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1CD84F16-BBB0-45B2-84E2-A7133C28A3E3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-32mr\\/es-a:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F7F20ED3-3BD1-4BC4-A0DA-0D74925E0C2F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-32mr\\/ua1_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3278D0F4-212B-440F-8952-328098996AC8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-32mr\\/ua1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F724663D-2DA6-42D3-892A-D7AAE8C2C8A6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-32ms\\/es_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "37EC00DB-D8BF-46DA-AF13-CF26F85F77E2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-32ms\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1E8DA5D5-183A-4804-93EB-09BE60093480",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-32mt\\/ds_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D0CE2A49-7C18-4103-AE0A-2C6E02411EAC",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-32mt\\/ds:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "93F07F53-68BC-4FDE-AC5B-8CFD45AEC0DA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-32mt\\/dss_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A8177335-A337-4061-9599-20B6A6BCACB7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-32mt\\/dss:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "742941D7-F375-455E-AEF4-4981D480A5CB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-32mt\\/es_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7DCB3423-E61A-473F-A5F6-2365A119D6F6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-32mt\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F91F9DF6-F1CE-467D-940E-6D8A832F8D1B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-32mt\\/es-a_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "553E29E6-8B15-421E-94FE-6C89C5E4F96D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-32mt\\/es-a:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "811BE72F-4A19-4C9C-8FBB-F102BDD2B5D5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-32mt\\/ess_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E72A8B32-F646-42EF-8CE3-BBD4FF1D8737",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-32mt\\/ess:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B74733B-D6EE-4E42-A600-7CBB42BC1F15",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-48mr\\/ds_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E214FC34-6AD6-4456-941F-476A2D52C0B2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-48mr\\/ds:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "85303A96-57A7-46AF-B794-556C753ED2E6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-48mr\\/es_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8DE00B76-C8BA-46A6-819D-4B0B412758CC",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-48mr\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6E5DE6E8-55AE-42F8-A324-BEEC0FA53A58",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-48mr\\/es-a_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AFBB22D5-7BF7-4F23-9402-013EC5D32F61",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-48mr\\/es-a:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "379C0410-CB4E-4972-9B9E-EC5695492301",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-48mt\\/ds_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F7A0634C-A048-4261-B6EF-B81AB0574B53",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-48mt\\/ds:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "28004AFA-4510-4674-9755-8F8FF16CDFE1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-48mt\\/dss_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "180B8CE9-46EE-4CFC-9513-E01FDBA15C2C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-48mt\\/dss:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D72828CB-EAB4-40CB-9348-3D24848FAC1A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-48mt\\/es_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6F986500-B77C-4699-9294-BFA1BF8DA326",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-48mt\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2DBD4BAA-014E-4277-B336-660809B4D2A4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-48mt\\/es-a_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "57D19440-9B12-4A30-A3C5-35E331339E16",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-48mt\\/es-a:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "72B1401A-5902-420C-843C-42A5D9E11AE9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-48mt\\/ess_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B9E4B675-836C-4360-8749-C08D01CAF0B8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-48mt\\/ess:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E02893B2-7AD4-4CC5-A6BA-757A4C57B31D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-64mr\\/ds_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1B867EF7-30AC-499B-A81E-A7FD3EE00DCE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-64mr\\/ds:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F8F9B997-4A54-451C-B7FA-BF85DCBD93B4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-64mr\\/es_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3E314572-A49C-4CBA-A9C9-F06F888D8530",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-64mr\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB5CFC2E-C936-449D-991C-733CB2FBB994",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-64mr\\/es-a_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1CB5DD71-AC57-48C5-A2A1-F045C9CF7D35",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-64mr\\/es-a:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "13B9AF49-681F-432E-8B31-2D2570B252E1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-64mr\\/ua1_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B3514A08-CBAF-4F10-A7C4-EC5B89D7A28D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-64mr\\/ua1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E0398640-0BBD-48B2-ACC0-3F2480B5FECF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-64ms\\/es_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AA5F6A62-6C15-486C-A8AC-CF14197DFA5F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-64ms\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E5570155-6AAA-4B51-8C8B-8AD8BFDC7181",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-64mt\\/ds_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4D1249B5-4141-4B4E-ACCC-A577F18D80AA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-64mt\\/ds:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "46A45C6D-F039-4A21-BF6E-96AD1AE684A1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-64mt\\/dss_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0F64A86A-69F2-497D-B38D-21D60821E1D1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-64mt\\/dss:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2A1E9620-66D0-4BCF-86D9-50F25F631869",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-64mt\\/es_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0239D43D-8167-4EA7-8580-A98E181D8B7F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-64mt\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1FF26626-6B52-4D5D-8E42-08F137A368F7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-64mt\\/es-a_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8BCB927C-6E5C-421A-A62B-DC2CA0A88224",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-64mt\\/es-a:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AA4118CD-4D88-498E-A63C-3332E8F49166",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-64mt\\/ess_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C685BA9-93C1-4130-BA00-5416252B92CE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-64mt\\/ess:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "288C04E9-CFE7-4877-9FE5-1E63ACBD3D9A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-80mr\\/ds_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DD59F4A3-DDF5-443F-AD0B-755CDA88B4CA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-80mr\\/ds:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "632A39FB-1F15-4B4A-994B-74A370093BE3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-80mr\\/es_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "02E937EB-2069-4415-A26C-1FDFE53AED25",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-80mr\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A56BA52D-A7E2-413D-96BA-4AF2B47ABF67",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-80mr\\/es-a_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1E3073D1-F083-499E-B3C4-CED326C2B1B1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-80mr\\/es-a:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "37C8DAD8-3CFC-46FA-A007-75AB027E5C9C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-80mt\\/ds_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BFC1D50D-F364-4BCF-B1EC-5D203F2C0FE9",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-80mt\\/ds:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "791E6428-8D18-4FA4-B93A-81022F98A2BC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-80mt\\/dss_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E1A3CCA1-B4A5-44C2-85BC-C651ABDE1E2A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-80mt\\/dss:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD52BAA5-66E2-4062-B03A-E391C277EE2D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-80mt\\/es_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "218BED8B-BF2E-43FD-8C50-9C845A512505",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-80mt\\/es:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F1A60072-A39D-47FB-9464-6954EDF90176",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-80mt\\/es-a_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "215557E1-0D0A-482B-B06B-F30BD59C8618",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-80mt\\/es-a:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8F42EF2A-AD06-43A0-9C59-1411F5416AB6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-80mt\\/ess_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "37B57E67-E801-4260-8452-37103A401523",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-80mt\\/ess:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1313D033-3620-406F-A7F3-90192BEFA32E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-enet_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFD943B0-4BD1-447D-9B7C-C5D62C067968",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-enet:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5D1644E1-F748-46A3-8E09-FF5D53FD046F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-enet-l_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F0C7FC7F-5BEF-4308-B237-79929D89595F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-enet-l:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C8ACC832-E1EC-46DA-A2D1-CF1A3791A885",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-enet-p502_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6F5A0639-3008-4ECE-9467-8036F4D6EFFC",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-enet-p502:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "69BA96DC-C462-4286-AE0E-32D141017E7F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3uc_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4C92EBEF-9479-4E84-9DAF-29D1F9784155",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3uc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A879DAAF-F3F5-4800-9C2F-0C6F38EEFC4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3uc-16mr\\/d-t_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2B067EE6-A82D-43FF-8E1C-134FC3E87221",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3uc-16mr\\/d-t:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2632C46A-CB9D-4AB9-8590-9857E15108A7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3uc-16mr\\/ds-t_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8A7B5607-0598-43E6-A59D-31C9E90D3FB2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3uc-16mr\\/ds-t:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "65F9960F-95CF-4C2E-B701-D14C2419B567",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3uc-16mt\\/d_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB3E50BC-0E52-46C3-A900-293431F52B8A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3uc-16mt\\/d:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D1AB8259-4ECC-4689-9870-8EC4ADBDAB83",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3uc-16mt\\/d-p4_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E8F3D044-F5B1-45D4-9DE6-D2883142410D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3uc-16mt\\/d-p4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A024062A-F427-411A-AC6B-73A2DA8C4913",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3uc-16mt\\/dss_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E76F9051-5720-4324-BDC8-269FE399E0E4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3uc-16mt\\/dss:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C5E55868-3A68-45AA-827B-E485A7A6A653",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3uc-16mt\\/dss-p4_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D52E035F-284D-4601-AD13-33DDB324AB32",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3uc-16mt\\/dss-p4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "89110E36-36EA-4DD1-99D1-01B642288F1D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3uc-32mt-lt_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "18D7B4E2-C884-4991-BC5A-68D1C7DB80DE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3uc-32mt-lt:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BF57E8A3-6C69-4D48-B400-49BE4B825398",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3uc-32mt-lt-2_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6724DBF8-D8BB-4FD3-B968-69EB3FF0BEE9",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3uc-32mt-lt-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "478A934A-6037-4F31-8380-94467509FD7A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3uc-32mt\\/d_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C7779FBF-9A59-4DB4-84B2-EDCE67645F78",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3uc-32mt\\/d:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "45BC5123-BBD6-45A0-A466-391A53010091",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3uc-32mt\\/dss_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C8D3E901-A445-456D-A642-73A8A7FA2640",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3uc-32mt\\/dss:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EB95C71D-EBE0-4F39-BC79-D47D266378DC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3uc-64mt\\/d_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F247CCA1-673F-4FCE-A2AD-30AF2C9603C5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3uc-64mt\\/d:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "26D64749-1E12-4744-8A06-E866DE240A35",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3uc-64mt\\/dss_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "895C814A-C07F-420F-A93C-6F2C2A908B5C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3uc-64mt\\/dss:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC74B68C-54E2-4CB3-8E8E-419033F29064",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3uc-96mt\\/d_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7D92D8E6-81A7-479A-9793-2F09204BDEA6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3uc-96mt\\/d:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "26669F78-0CFF-4AF1-9841-037E618CB14E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3uc-96mt\\/dss_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9E743BF6-7957-4DAF-93E0-B365B2CED03F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3uc-96mt\\/dss:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BF0132BB-9968-47D7-A692-135A60478967",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Improper Authentication vulnerability in Mitsubishi Electric Corporation MELSEC-F Series main modules allows a remote unauthenticated attacker to obtain sequence programs from the product or write malicious sequence programs or improper data in the product without authentication by sending illegitimate messages.\n\n\n\n\n\n\n"
    },
    {
      "lang": "es",
      "value": "Vulnerabilidad de autenticaci\u00f3n incorrecta en los m\u00f3dulos principales de la serie MELSEC-F de Mitsubishi Electric Corporation permite que un atacante remoto no autenticado obtenga programas de secuencia del producto o escriba programas de secuencia maliciosos o datos inadecuados en el producto sin autenticaci\u00f3n mediante el env\u00edo de mensajes ileg\u00edtimos."
    }
  ],
  "id": "CVE-2023-4562",
  "lastModified": "2024-11-21T08:35:25.693",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 9.1,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.2,
        "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 9.1,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.2,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-10-13T02:15:09.917",
  "references": [
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://jvn.jp/vu/JVNVU90509290/"
    },
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-285-13"
    },
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-012_en.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://jvn.jp/vu/JVNVU90509290/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-285-13"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-012_en.pdf"
    }
  ],
  "sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-287"
        }
      ],
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-287"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-01-14 20:15
Modified
2024-11-21 05:46
Summary
Lack of administrator control over security vulnerability in MELSEC-F series FX3U-ENET Firmware version 1.14 and prior, FX3U-ENET-L Firmware version 1.14 and prior and FX3U-ENET-P502 Firmware version 1.14 and prior allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition in communication function of the product or other unspecified effects by sending specially crafted packets to an unnecessary opening of TCP port. Control by MELSEC-F series PLC is not affected by this vulnerability, but system reset is required for recovery.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-enet_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BF1D75C8-9E0A-4A2A-A9B6-3A944721DFC4",
              "versionEndIncluding": "1.14",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-enet:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5D1644E1-F748-46A3-8E09-FF5D53FD046F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-enet-l_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C54E1F47-E0A3-4C49-A219-84175C7B8108",
              "versionEndIncluding": "1.14",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-enet-l:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C8ACC832-E1EC-46DA-A2D1-CF1A3791A885",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-enet-p502_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "72D73FF4-10B4-4F70-B603-27775A21B9F1",
              "versionEndIncluding": "1.14",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-enet-p502:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "69BA96DC-C462-4286-AE0E-32D141017E7F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Lack of administrator control over security vulnerability in MELSEC-F series FX3U-ENET Firmware version 1.14 and prior, FX3U-ENET-L Firmware version 1.14 and prior and FX3U-ENET-P502 Firmware version 1.14 and prior allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition in communication function of the product or other unspecified effects by sending specially crafted packets to an unnecessary opening of TCP port. Control by MELSEC-F series PLC is not affected by this vulnerability, but system reset is required for recovery."
    },
    {
      "lang": "es",
      "value": "Una falta de control del administrador sobre la vulnerabilidad de seguridad en la serie MELSEC-F FX3U-ENET Firmware versi\u00f3n 1.14 y anteriores, FX3U-ENET-L Firmware versi\u00f3n 1.14 y anteriores y FX3U-ENET-P502 Firmware versi\u00f3n 1.14 y anteriores permite que un atacante remoto no autenticado cause una condici\u00f3n de denegaci\u00f3n de servicio (DoS) en la funci\u00f3n de comunicaci\u00f3n del producto u otros efectos no especificados mediante el env\u00edo de paquetes especialmente dise\u00f1ados a una apertura no necesaria del puerto TCP. El control por parte del PLC de la serie MELSEC-F no est\u00e1 afectado por esta vulnerabilidad, pero es necesario reiniciar el sistema para recuperarlo"
    }
  ],
  "id": "CVE-2021-20612",
  "lastModified": "2024-11-21T05:46:52.860",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 7.8,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-01-14T20:15:09.850",
  "references": [
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://jvn.jp/vu/JVNVU93268332/index.html"
    },
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-013-01"
    },
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-023_en.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://jvn.jp/vu/JVNVU93268332/index.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-013-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-023_en.pdf"
    }
  ],
  "sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-Other"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-01-14 20:15
Modified
2024-11-21 05:46
Summary
Improper initialization vulnerability in MELSEC-F series FX3U-ENET Firmware version 1.16 and prior, FX3U-ENET-L Firmware version 1.16 and prior and FX3U-ENET-P502 Firmware version 1.16 and prior allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition in communication function of the product by sending specially crafted packets. Control by MELSEC-F series PLC is not affected by this vulnerability, but system reset is required for recovery.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-enet_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D944AA19-7039-45F8-BEAB-FF26B572644B",
              "versionEndIncluding": "1.16",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-enet:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5D1644E1-F748-46A3-8E09-FF5D53FD046F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-enet-l_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F5905695-3181-4693-AE7C-0C3ED9AADD71",
              "versionEndIncluding": "1.16",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-enet-l:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C8ACC832-E1EC-46DA-A2D1-CF1A3791A885",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:fx3u-enet-p502_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2960D0F8-64F3-4533-8FE1-8B76609406F2",
              "versionEndIncluding": "1.16",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:fx3u-enet-p502:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "69BA96DC-C462-4286-AE0E-32D141017E7F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Improper initialization vulnerability in MELSEC-F series FX3U-ENET Firmware version 1.16 and prior, FX3U-ENET-L Firmware version 1.16 and prior and FX3U-ENET-P502 Firmware version 1.16 and prior allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition in communication function of the product by sending specially crafted packets. Control by MELSEC-F series PLC is not affected by this vulnerability, but system reset is required for recovery."
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad de inicializaci\u00f3n inapropiada en FX3U-ENET serie MELSEC-F, versiones de Firmware 1.16 y anteriores, FX3U-ENET-L versiones de Firmware 1.16 y anteriores, y FX3U-ENET-P502 versiones de Firmware 1.16 y anteriores, permite a un atacante remoto no autenticado causar una condici\u00f3n de denegaci\u00f3n de servicio (DoS) en la funci\u00f3n de comunicaci\u00f3n del producto mediante el env\u00edo de paquetes especialmente dise\u00f1ados. El control por parte del PLC de la serie MELSEC-F no est\u00e1 afectado por esta vulnerabilidad, pero es necesario reiniciar el sistema para recuperarlo"
    }
  ],
  "id": "CVE-2021-20613",
  "lastModified": "2024-11-21T05:46:52.977",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 7.8,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-01-14T20:15:09.910",
  "references": [
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://jvn.jp/vu/JVNVU93268332/index.html"
    },
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-013-07"
    },
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-024_en.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://jvn.jp/vu/JVNVU93268332/index.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-013-07"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-024_en.pdf"
    }
  ],
  "sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-665"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

var-202201-1492
Vulnerability from variot

Lack of administrator control over security vulnerability in MELSEC-F series FX3U-ENET Firmware version 1.14 and prior, FX3U-ENET-L Firmware version 1.14 and prior and FX3U-ENET-P502 Firmware version 1.14 and prior allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition in communication function of the product or other unspecified effects by sending specially crafted packets to an unnecessary opening of TCP port. Control by MELSEC-F series PLC is not affected by this vulnerability, but system reset is required for recovery.

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202201-1492",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "fx3u-enet",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "1.14"
      },
      {
        "model": "fx3u-enet-l",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "1.14"
      },
      {
        "model": "fx3u-enet-p502",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "1.14"
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-20612"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx3u-enet_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndIncluding": "1.14",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx3u-enet:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx3u-enet_firmware:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndIncluding": "1.14",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx3u-enet:-:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": false
              }
            ],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx3u-enet-l_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndIncluding": "1.14",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx3u-enet-l:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx3u-enet-l_firmware:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndIncluding": "1.14",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx3u-enet-l:-:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": false
              }
            ],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx3u-enet-p502_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndIncluding": "1.14",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx3u-enet-p502:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx3u-enet-p502_firmware:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndIncluding": "1.14",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx3u-enet-p502:-:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": false
              }
            ],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-20612"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Mitsubishi Electric reported this vulnerability to CISA.",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202201-1079"
      }
    ],
    "trust": 0.6
  },
  "cve": "CVE-2021-20612",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2021-20612",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "HIGH",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "id": "CVE-2021-20612",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2021-20612",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202201-1079",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202201-1079"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-20612"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Lack of administrator control over security vulnerability in MELSEC-F series FX3U-ENET Firmware version 1.14 and prior, FX3U-ENET-L Firmware version 1.14 and prior and FX3U-ENET-P502 Firmware version 1.14 and prior allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition in communication function of the product or other unspecified effects by sending specially crafted packets to an unnecessary opening of TCP port. Control by MELSEC-F series PLC is not affected by this vulnerability, but system reset is required for recovery.",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-20612"
      }
    ],
    "trust": 1.0
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "JVN",
        "id": "JVNVU93268332",
        "trust": 1.6
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-22-013-01",
        "trust": 1.6
      },
      {
        "db": "NVD",
        "id": "CVE-2021-20612",
        "trust": 1.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202201-1079",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202201-1079"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-20612"
      }
    ]
  },
  "id": "VAR-202201-1492",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 1.0
  },
  "last_update_date": "2022-05-04T09:08:18.981000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Mitsubishi Electric MELSEC-F Series Security vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=177947"
      }
    ],
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202201-1079"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-798",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-20612"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.6,
        "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-023_en.pdf"
      },
      {
        "trust": 1.6,
        "url": "https://jvn.jp/vu/jvnvu93268332/index.html"
      },
      {
        "trust": 1.6,
        "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-013-01"
      },
      {
        "trust": 0.6,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2021-20612"
      },
      {
        "trust": 0.6,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-013-01"
      }
    ],
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202201-1079"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-20612"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202201-1079"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-20612"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-01-13T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202201-1079"
      },
      {
        "date": "2022-01-14T20:15:00",
        "db": "NVD",
        "id": "CVE-2021-20612"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-02-09T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202201-1079"
      },
      {
        "date": "2022-01-21T18:11:00",
        "db": "NVD",
        "id": "CVE-2021-20612"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202201-1079"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Mitsubishi Electric MELSEC-F Series Trust Management Issue Vulnerability",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202201-1079"
      }
    ],
    "trust": 0.6
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "trust management problem",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202201-1079"
      }
    ],
    "trust": 0.6
  }
}

var-202010-0395
Vulnerability from variot

Multiple Mitsubishi Electric products are vulnerable to impersonations of a legitimate device by a malicious actor, which may allow an attacker to remotely execute arbitrary commands. of multiple Mitsubishi Electric products TCP A vulnerability in session management exists in the protocol stack. This vulnerability information is provided by the developer for the purpose of dissemination to product users. Authentication is not required to exploit this vulnerability.The specific flaw exists within the processing of ACK packets. When generating ACK packets, the application uses a predictable sequence number. An attacker can leverage this vulnerability to execute arbitrary code in the context of the current process. Mitsubishi Electric gt14 model是日本三菱电机(Mitsubishi Electric)公司的一个用于工业生产过程中提供人机交互界面的设备. Mitsubishi Electric 多个产品存在命令执行漏洞,该漏洞允许攻击者冒充合法设备,从而使攻击者能够远程执行任意命令。以下产品和版本受到影响:QJ71MES96 all versions,QJ71WS96 all versions,Q06CCPU-V all versions,Q24DHCCPU-V all versions,Q24DHCCPU-VG all versions,R12CCPU-V Version 13 and prior,RD55UP06-V Version 09 and prior,RD55UP12-V Version 01,RJ71GN11-T2 Version 11 and prior,RJ71EN71 all versions,QJ71E71-100 all versions,LJ71E71-100 all versions,QJ71MT91 all versions,RD78Gn(n=4,8,16,32,64) all versions,RD78GHV all versions,RD78GHW all versions,NZ2GACP620-60 all versions,NZ2GACP620-300 all versions,NZ2FT-MT all versions,NZ2FT-EIP all versions,Q03UDECPU the first 5 digits of serial number 22081 and prior,QnUDEHCPU(n=04/06/10/13/20/26/50/100) the first 5 digits of serial number 22081 and prior,QnUDVCPU(n=03/04/06/13/26) the first 5 digits of serial number 22031 and prior,QnUDPVCPU(n=04/06/13/26) the first 5 digits of serial number 22031 and prior,LnCPU(-P)(n=02/06/26) the first 5 digits of serial number 22051 and prior,L26CPU-(P)BT the first 5 digits of serial number 22051 and prior,RnCPU(n=00/01/02) Version 18 and prior,RnCPU(n=04/08/16/32/120) Version 50 and prior,RnENCPU(n=04/08/16/32/120) Version 50 and prior,RnSFCPU (n=08/16/32/120) Version 22 and prior,RnPCPU(n=08/16/32/120) Version 24 and prior,RnPSFCPU(n=08/16/32/120) Version 05 and prior,FX5U(C)-M*/,FX5UC-32M/-TS Version 1.210 and prior,FX5UJ-M/ Version 1.000,FX5-ENET Version 1.002 and prior,FX5-ENET/IP Version 1.002 and prior,FX3U-ENET-ADP Version 1.22 and prior,FX3GE-M/* the first 3 digits of serial number 20X and prior,FX3U-ENET Version 1.14 and prior,FX3U-ENET-L Version 1.14 and prior,FX3U-ENET-P502 Version 1.14 and prior,FX5-CCLGN-MS Version 1.000,IU1-1M20-D all versions,LE7-40GU-L all versions,GOT2000 Series GT21 Model all versions,GS Series all versions,GOT1000 Series GT14 Model all versions,GT25-J71GN13-T2 all versions,FR-A800-E Series production date December 2020 and prior,FR-F800-E Series production date December 2020 and prior,FR-A8NCG Production date August 2020 and prior,FR-E800-EPA Series Production date July 2020 and prior,FR-E800-EPB Series Production date July 2020 and prior,Conveyor Tracking Application APR-nTR3FH APR-nTR6FH APR-nTR12FH APR-nTR20FH(n=1,2) all versions (Discontinued product),MR-JE-C all versions,MR-J4-TM all versions

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202010-0395",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "rd55up12-v",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fx5uj-60mr\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "1.000"
      },
      {
        "model": "got2000 series gt21",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fx5uc-32mt\\/ds-ts",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "1.210"
      },
      {
        "model": "le7-40gu-l",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fx5uj-60mt\\/ess",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "1.000"
      },
      {
        "model": "qnudpvcpu\\",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "22031"
      },
      {
        "model": "fx3g-40mt\\/dss",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fx5uj-24mt\\/ess",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "1.000"
      },
      {
        "model": "fx3g-60mt\\/ess",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fr-f820-e",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fr-a8ncge",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "2020-08"
      },
      {
        "model": "gt25-j71gn13-t2",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fx3g-40mt\\/ess",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fr-f860-e",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fx5-cclgn-ms",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fx3g-32 mt\\/dss",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fx5uj-40mr\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "1.000"
      },
      {
        "model": "nz2gacp620-60",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fx3g-14mr\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "l26cpu-\\ bt",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "22051"
      },
      {
        "model": "fx5uj-40mt\\/ess",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "1.000"
      },
      {
        "model": "fr-f840-e",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "r12ccpu-v",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "rnpcpu\\",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fx3u-enet-l",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fx3g-40mr\\/ds",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "rncpu\\",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "50"
      },
      {
        "model": "conveyor tracking application apr-ntr6fh",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "iu1-1m20-d",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "rnsfcpu \\",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "rj71gn11-t2",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "rnpsfcpu\\",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fx5-enet\\/ip",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fx3g-24mt\\/ess",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "conveyor tracking application apr-ntr12fh",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "rd78ghw",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "rj71en71",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "qj71e71-100",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fx5uj-40mt\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "1.000"
      },
      {
        "model": "fx3u-enet",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "q24dhccpu-v",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "qj71ws96",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "q24dhccpu-vg",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "got simple series gs21",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "conveyor tracking application apr-ntr20fh\\",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fr-a840-e",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fx3g-14mr\\/ds",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "conveyor tracking application apr-ntr3fh",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fr-a860-e",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "rd78ghv",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "q03udecpu",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "22081"
      },
      {
        "model": "fx5uj-24mt\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "1.000"
      },
      {
        "model": "nz2gacp620-300",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fx3g-24mt\\/dss",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "rd78gn\\",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fr-f862-e",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "rnencpu\\",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "50"
      },
      {
        "model": "mr-je-c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fx5uc-32mt\\/d",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "1.210"
      },
      {
        "model": "fx5uc-32mt\\/dss-ts",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "1.210"
      },
      {
        "model": "fr-a842-e",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fx3g-60mr\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "rd55up06-v",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "got1000 series gt14",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fx5-enet",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "qj71mt91",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fr-a820-e",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "qnudvcpu\\",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "22031"
      },
      {
        "model": "fr-a862-e",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fx5uc-32mr\\/ds-ts",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "1.210"
      },
      {
        "model": "fx5uj-24mr\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "1.000"
      },
      {
        "model": "mr-j4-tm",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fx3u-enet-p502",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "qj71mes96",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "nz2ft-eip",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "lncpu\\ \\",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "22051"
      },
      {
        "model": "fx5uj-60mt\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "1.000"
      },
      {
        "model": "fr-e800-epa",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "2020-07"
      },
      {
        "model": "rncpu\\ t",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "18"
      },
      {
        "model": "fr-f842-e",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fx3g-60mr\\/ds",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fx3g-24mr\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fx3g-14mt\\/dss",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fx5uc-32mt\\/dss",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "1.210"
      },
      {
        "model": "fx5-enet-adp",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "q06ccpu-v",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fx3g-60mt\\/dss",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fr-e800-epb",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "2020-07"
      },
      {
        "model": "lj71e71-100",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "nz2ft-mt",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fx3g-14mt\\/ess",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "fx3g-40mr\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "qnudehcpu\\",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "22081"
      },
      {
        "model": "fx3g-24mr\\/ds",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "*"
      },
      {
        "model": "\uff08\u8907\u6570\u306e\u88fd\u54c1\uff09",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": "(multiple products)"
      },
      {
        "model": "\uff08\u8907\u6570\u306e\u88fd\u54c1\uff09",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": "it was * ac the servo  melservo"
      },
      {
        "model": "\uff08\u8907\u6570\u306e\u88fd\u54c1\uff09",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": "it was * lossnay central ventilation system"
      },
      {
        "model": "\uff08\u8907\u6570\u306e\u88fd\u54c1\uff09",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": "it was * display  got"
      },
      {
        "model": "\uff08\u8907\u6570\u306e\u88fd\u54c1\uff09",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": null
      },
      {
        "model": "\uff08\u8907\u6570\u306e\u88fd\u54c1\uff09",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": "it was * air conditioning control system  / centralized controller"
      },
      {
        "model": "\uff08\u8907\u6570\u306e\u88fd\u54c1\uff09",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": "it was * air conditioning control system  / expansion controller"
      },
      {
        "model": "\uff08\u8907\u6570\u306e\u88fd\u54c1\uff09",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": "it was * energy measurement unit"
      },
      {
        "model": "\uff08\u8907\u6570\u306e\u88fd\u54c1\uff09",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": "affected products    s vary widely. for more information, please check the information provided by the developer."
      },
      {
        "model": "\uff08\u8907\u6570\u306e\u88fd\u54c1\uff09",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": "it was * range hood fan"
      },
      {
        "model": "\uff08\u8907\u6570\u306e\u88fd\u54c1\uff09",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": "it was * data collection analyzer  melqic"
      },
      {
        "model": "\uff08\u8907\u6570\u306e\u88fd\u54c1\uff09",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": "it was * hems compatible adapter, lan adapter"
      },
      {
        "model": "\uff08\u8907\u6570\u306e\u88fd\u54c1\uff09",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": "it was * air conditioning control system  / bm adapter"
      },
      {
        "model": "\uff08\u8907\u6570\u306e\u88fd\u54c1\uff09",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": "it was * room air conditioner"
      },
      {
        "model": "\uff08\u8907\u6570\u306e\u88fd\u54c1\uff09",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": "it was * bath drying/heating/ventilation system"
      },
      {
        "model": "\uff08\u8907\u6570\u306e\u88fd\u54c1\uff09",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": "it was * solar power system color monitor eco guide"
      },
      {
        "model": "\uff08\u8907\u6570\u306e\u88fd\u54c1\uff09",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": "it was * ventilation fan for duct"
      },
      {
        "model": "\uff08\u8907\u6570\u306e\u88fd\u54c1\uff09",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": "it was * tension controller"
      },
      {
        "model": "\uff08\u8907\u6570\u306e\u88fd\u54c1\uff09",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": "it was * inverter  freqrol"
      },
      {
        "model": "\uff08\u8907\u6570\u306e\u88fd\u54c1\uff09",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": "it was * mitsubishi energy saving dem  monitoring server  e-energy"
      },
      {
        "model": "\uff08\u8907\u6570\u306e\u88fd\u54c1\uff09",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": "it was * robot  melfa"
      },
      {
        "model": "melsec iq-f",
        "scope": null,
        "trust": 0.7,
        "vendor": "mitsubishi electric",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-20-1207"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-008251"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-16226"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:qj71mes96_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:qj71mes96:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:qj71ws96_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:qj71ws96:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:q06ccpu-v_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:q06ccpu-v:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:q24dhccpu-v_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:q24dhccpu-v:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:q24dhccpu-vg_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:q24dhccpu-vg:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:r12ccpu-v_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:r12ccpu-v:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:rd55up06-v_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:rd55up06-v:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:rd55up12-v_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:rd55up12-v:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:rj71gn11-t2_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:rj71gn11-t2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:rj71en71_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:rj71en71:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:qj71e71-100_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:qj71e71-100:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:lj71e71-100_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:lj71e71-100:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:qj71mt91_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:qj71mt91:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:rd78gn\\(n\\=4\\,8\\,16\\,32\\,64\\)_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:rd78gn\\(n\\=4\\,8\\,16\\,32\\,64\\):-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:rd78ghv_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:rd78ghv:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:rd78ghw_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:rd78ghw:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:nz2gacp620-60_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:nz2gacp620-60:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:nz2gacp620-300_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:nz2gacp620-300:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:nz2ft-mt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:nz2ft-mt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:nz2ft-eip_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:nz2ft-eip:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:q03udecpu_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndIncluding": "22081",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:q03udecpu:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:qnudehcpu\\(n\\=04\\/06\\/10\\/13\\/20\\/26\\/50\\/100\\)_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndIncluding": "22081",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:qnudehcpu\\(n\\=04\\/06\\/10\\/13\\/20\\/26\\/50\\/100\\):-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:qnudvcpu\\(n\\=03\\/04\\/06\\/13\\/26\\)_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndIncluding": "22031",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:qnudvcpu\\(n\\=03\\/04\\/06\\/13\\/26\\):-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:qnudpvcpu\\(n\\=04\\/06\\/13\\/2\\)_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndIncluding": "22031",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:qnudpvcpu\\(n\\=04\\/06\\/13\\/2\\):-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:lncpu\\(-p\\)\\(n\\=02\\/06\\/26\\)_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndIncluding": "22051",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:lncpu\\(-p\\)\\(n\\=02\\/06\\/26\\):-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:l26cpu-\\(p\\)bt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndIncluding": "22051",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:l26cpu-\\(p\\)bt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:rncpu\\(n\\=00\\/01\\/02\\)t_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndIncluding": "18",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:rncpu\\(n\\=00\\/01\\/02\\)t:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:rncpu\\(n\\=04\\/08\\/16\\/32\\/120\\)_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndIncluding": "50",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:rncpu\\(n\\=04\\/08\\/16\\/32\\/120\\):-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:rnencpu\\(n\\=04\\/08\\/16\\/32\\/120\\)_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndIncluding": "50",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:rnencpu\\(n\\=04\\/08\\/16\\/32\\/120\\):-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:rnsfcpu_\\(n\\=08\\/16\\/32\\/120\\)_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:rnsfcpu_\\(n\\=08\\/16\\/32\\/120\\):-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:rnpcpu\\(n\\=08\\/16\\/32\\/120\\)_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:rnpcpu\\(n\\=08\\/16\\/32\\/120\\):-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:rnpsfcpu\\(n\\=08\\/16\\/32\\/120\\)_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:rnpsfcpu\\(n\\=08\\/16\\/32\\/120\\):-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx5uc-32mt\\/d_firmware:1.210:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx5uc-32mt\\/d:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx5uc-32mt\\/dss_firmware:1.210:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx5uc-32mt\\/dss:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx5uc-32mt\\/ds-ts_firmware:1.210:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx5uc-32mt\\/ds-ts:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx5uc-32mt\\/dss-ts_firmware:1.210:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx5uc-32mt\\/dss-ts:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx5uj-24mr\\/es_firmware:1.000:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx5uj-24mr\\/es:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx5uc-32mr\\/ds-ts_firmware:1.210:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx5uc-32mr\\/ds-ts:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx5uj-24mt\\/es_firmware:1.000:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx5uj-24mt\\/es:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx5uj-24mt\\/ess_firmware:1.000:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx5uj-24mt\\/ess:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx5uj-40mr\\/es_firmware:1.000:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx5uj-40mr\\/es:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx5uj-40mt\\/es_firmware:1.000:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx5uj-40mt\\/es:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx5uj-40mt\\/ess_firmware:1.000:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx5uj-40mt\\/ess:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx5uj-60mr\\/es_firmware:1.000:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx5uj-60mr\\/es:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx5uj-60mt\\/es_firmware:1.000:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx5uj-60mt\\/es:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx5uj-60mt\\/ess_firmware:1.000:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx5uj-60mt\\/ess:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx5-enet_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx5-enet:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx5-enet\\/ip_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx5-enet\\/ip:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx5-enet-adp_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx5-enet-adp:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx3g-14mr\\/es_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx3g-14mr\\/es:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx3g-14mt\\/ess_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx3g-14mt\\/ess:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx3g-14mr\\/ds_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx3g-14mr\\/ds:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx3g-14mt\\/dss_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx3g-14mt\\/dss:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx3g-24mr\\/es_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx3g-24mr\\/es:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx3g-24mt\\/ess_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx3g-24mt\\/ess:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx3g-24mr\\/ds_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx3g-24mr\\/ds:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx3g-24mt\\/dss_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx3g-24mt\\/dss:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx3g-40mr\\/es_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx3g-40mr\\/es:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx3g-40mt\\/ess_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx3g-40mt\\/ess:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx3g-40mr\\/ds_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx3g-40mr\\/ds:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx3g-40mt\\/dss_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx3g-40mt\\/dss:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx3g-60mr\\/es_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx3g-60mr\\/es:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx3g-60mt\\/ess_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx3g-60mt\\/ess:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx3g-60mr\\/ds_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx3g-60mr\\/ds:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx3g-60mt\\/dss_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx3g-60mt\\/dss:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx3g-24mr\\/es_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx3g-24mr\\/es:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx3g-24mt\\/ess_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx3g-24mt\\/ess:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx3g-24mr\\/ds_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx3g-24mr\\/ds:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx3g-24mt\\/dss_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx3g-24mt\\/dss:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx3g-40mr\\/es_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx3g-40mr\\/es:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx3g-40mt\\/ess_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx3g-40mt\\/ess:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx3g-40mr\\/ds_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx3g-40mr\\/ds:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx3g-40mt\\/dss_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx3g-40mt\\/dss:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx3g-32_mt\\/dss_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx3g-32_mt\\/dss:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx3u-enet_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx3u-enet:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx3u-enet-l_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx3u-enet-l:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx3u-enet-p502_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx3u-enet-p502:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx5-cclgn-ms_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx5-cclgn-ms:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:iu1-1m20-d_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:iu1-1m20-d:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:le7-40gu-l_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:le7-40gu-l:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:got2000_series_gt21_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:got2000_series_gt21:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:got_simple_series_gs21_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:got_simple_series_gs21:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:got1000_series_gt14_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:got1000_series_gt14:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:gt25-j71gn13-t2_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:gt25-j71gn13-t2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fr-a820-e_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fr-a820-e:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fr-a840-e_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fr-a840-e:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fr-a860-e_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fr-a860-e:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fr-a842-e_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fr-a842-e:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fr-a862-e_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fr-a862-e:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fr-f820-e_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fr-f820-e:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fr-f840-e_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fr-f840-e:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fr-f860-e_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fr-f860-e:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fr-f842-e_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fr-f842-e:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fr-f862-e_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fr-f862-e:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fr-a8ncge_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndIncluding": "2020-08",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fr-a8ncge:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fr-e800-epa_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndIncluding": "2020-07",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fr-e800-epa:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fr-e800-epb_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndIncluding": "2020-07",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fr-e800-epb:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:mitsubishielectric:conveyor_tracking_application_apr-ntr12fh:-:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:mitsubishielectric:conveyor_tracking_application_apr-ntr20fh\\(n\\=1\\,2\\):-:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:mitsubishielectric:conveyor_tracking_application_apr-ntr3fh:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:mitsubishielectric:conveyor_tracking_application_apr-ntr6fh:-:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              }
            ],
            "operator": "OR"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:mr-je-c_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:mr-je-c:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:mr-j4-tm_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:mr-j4-tm:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-16226"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Ta-Lun Yen of TXOne IoT/ICS Security Research Labs (Trend Micro)",
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-20-1207"
      }
    ],
    "trust": 0.7
  },
  "cve": "CVE-2020-16226",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "HIGH",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULMON",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2020-16226",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "HIGH",
            "trust": 0.1,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "Low",
            "baseScore": 7.3,
            "baseSeverity": "High",
            "confidentialityImpact": "Low",
            "exploitabilityScore": null,
            "id": "CVE-2020-16226",
            "impactScore": null,
            "integrityImpact": "Low",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.0"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "ZDI",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2020-16226",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 0.7,
            "userInteraction": "NONE",
            "vectorString": "AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2020-16226",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2020-16226",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "ZDI",
            "id": "CVE-2020-16226",
            "trust": 0.7,
            "value": "CRITICAL"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202009-074",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "VULMON",
            "id": "CVE-2020-16226",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-20-1207"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-16226"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-008251"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-16226"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202009-074"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Multiple Mitsubishi Electric products are vulnerable to impersonations of a legitimate device by a malicious actor, which may allow an attacker to remotely execute arbitrary commands. of multiple Mitsubishi Electric products TCP A vulnerability in session management exists in the protocol stack. This vulnerability information is provided by the developer for the purpose of dissemination to product users. Authentication is not required to exploit this vulnerability.The specific flaw exists within the processing of ACK packets. When generating ACK packets, the application uses a predictable sequence number. An attacker can leverage this vulnerability to execute arbitrary code in the context of the current process. Mitsubishi Electric gt14 model\u662f\u65e5\u672c\u4e09\u83f1\u7535\u673a\uff08Mitsubishi Electric\uff09\u516c\u53f8\u7684\u4e00\u4e2a\u7528\u4e8e\u5de5\u4e1a\u751f\u4ea7\u8fc7\u7a0b\u4e2d\u63d0\u4f9b\u4eba\u673a\u4ea4\u4e92\u754c\u9762\u7684\u8bbe\u5907. \nMitsubishi Electric \u591a\u4e2a\u4ea7\u54c1\u5b58\u5728\u547d\u4ee4\u6267\u884c\u6f0f\u6d1e\uff0c\u8be5\u6f0f\u6d1e\u5141\u8bb8\u653b\u51fb\u8005\u5192\u5145\u5408\u6cd5\u8bbe\u5907\uff0c\u4ece\u800c\u4f7f\u653b\u51fb\u8005\u80fd\u591f\u8fdc\u7a0b\u6267\u884c\u4efb\u610f\u547d\u4ee4\u3002\u4ee5\u4e0b\u4ea7\u54c1\u548c\u7248\u672c\u53d7\u5230\u5f71\u54cd\uff1aQJ71MES96 all versions\uff0cQJ71WS96 all versions\uff0cQ06CCPU-V all versions\uff0cQ24DHCCPU-V all versions\uff0cQ24DHCCPU-VG all versions\uff0cR12CCPU-V Version 13 and prior\uff0cRD55UP06-V Version 09 and prior\uff0cRD55UP12-V Version 01\uff0cRJ71GN11-T2 Version 11 and prior\uff0cRJ71EN71 all versions\uff0cQJ71E71-100 all versions\uff0cLJ71E71-100 all versions\uff0cQJ71MT91 all versions\uff0cRD78Gn(n=4,8,16,32,64) all versions\uff0cRD78GHV all versions\uff0cRD78GHW all versions\uff0cNZ2GACP620-60 all versions\uff0cNZ2GACP620-300 all versions\uff0cNZ2FT-MT all versions\uff0cNZ2FT-EIP all versions\uff0cQ03UDECPU the first 5 digits of serial number 22081 and prior\uff0cQnUDEHCPU(n=04/06/10/13/20/26/50/100) the first 5 digits of serial number 22081 and prior\uff0cQnUDVCPU(n=03/04/06/13/26) the first 5 digits of serial number 22031 and prior\uff0cQnUDPVCPU(n=04/06/13/26) the first 5 digits of serial number 22031 and prior\uff0cLnCPU(-P)(n=02/06/26) the first 5 digits of serial number 22051 and prior\uff0cL26CPU-(P)BT the first 5 digits of serial number 22051 and prior\uff0cRnCPU(n=00/01/02) Version 18 and prior\uff0cRnCPU(n=04/08/16/32/120) Version 50 and prior\uff0cRnENCPU(n=04/08/16/32/120) Version 50 and prior\uff0cRnSFCPU (n=08/16/32/120) Version 22 and prior\uff0cRnPCPU(n=08/16/32/120) Version 24 and prior\uff0cRnPSFCPU(n=08/16/32/120) Version 05 and prior\uff0cFX5U(C)-**M*/**\uff0cFX5UC-32M*/**-TS Version 1.210 and prior\uff0cFX5UJ-**M*/** Version 1.000\uff0cFX5-ENET Version 1.002 and prior\uff0cFX5-ENET/IP Version 1.002 and prior\uff0cFX3U-ENET-ADP Version 1.22 and prior\uff0cFX3GE-**M*/** the first 3 digits of serial number 20X and prior\uff0cFX3U-ENET Version 1.14 and prior\uff0cFX3U-ENET-L Version 1.14 and prior\uff0cFX3U-ENET-P502 Version 1.14 and prior\uff0cFX5-CCLGN-MS Version 1.000\uff0cIU1-1M20-D all versions\uff0cLE7-40GU-L all versions\uff0cGOT2000 Series GT21 Model all versions\uff0cGS Series all versions\uff0cGOT1000 Series GT14 Model all versions\uff0cGT25-J71GN13-T2 all versions\uff0cFR-A800-E Series production date December 2020 and prior\uff0cFR-F800-E Series production date December 2020 and prior\uff0cFR-A8NCG Production date August 2020 and prior\uff0cFR-E800-EPA Series Production date July 2020 and prior\uff0cFR-E800-EPB Series Production date July 2020 and prior\uff0cConveyor Tracking Application APR-nTR3FH APR-nTR6FH APR-nTR12FH APR-nTR20FH(n=1,2) all versions (Discontinued product)\uff0cMR-JE-C all versions\uff0cMR-J4-TM all versions",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-16226"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-008251"
      },
      {
        "db": "ZDI",
        "id": "ZDI-20-1207"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202009-074"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-16226"
      }
    ],
    "trust": 2.88
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2020-16226",
        "trust": 3.2
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-20-245-01",
        "trust": 2.5
      },
      {
        "db": "JVN",
        "id": "JVNVU93926439",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-008251",
        "trust": 0.8
      },
      {
        "db": "ZDI_CAN",
        "id": "ZDI-CAN-10966",
        "trust": 0.7
      },
      {
        "db": "ZDI",
        "id": "ZDI-20-1207",
        "trust": 0.7
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2020.3041",
        "trust": 0.6
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2022.4767",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202009-074",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-16226",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-20-1207"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-16226"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-008251"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-16226"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202009-074"
      }
    ]
  },
  "id": "VAR-202010-0395",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.41666666
  },
  "last_update_date": "2023-12-18T13:27:59.258000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "of our products TCP Spoofing Vulnerability in Protocol Stack",
        "trust": 0.8,
        "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-009.pdf"
      },
      {
        "title": "Mitsubishi Electric has issued an update to correct this vulnerability.",
        "trust": 0.7,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-245-01"
      },
      {
        "title": "mitsubishielectric Fixes for remote command execution vulnerabilities",
        "trust": 0.6,
        "url": "http://123.124.177.30/web/xxk/bdxqbyid.tag?id=127702"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-20-1207"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-008251"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202009-074"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-342",
        "trust": 1.0
      },
      {
        "problemtype": "Lack of information (CWE-noinfo) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-008251"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-16226"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.8,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-245-01"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu93926439/"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2020.3041/"
      },
      {
        "trust": 0.6,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-16226"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2022.4767"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/342.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      },
      {
        "trust": 0.1,
        "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-245-01"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-20-1207"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-16226"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-008251"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-16226"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202009-074"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "ZDI",
        "id": "ZDI-20-1207"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-16226"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-008251"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-16226"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202009-074"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-09-08T00:00:00",
        "db": "ZDI",
        "id": "ZDI-20-1207"
      },
      {
        "date": "2020-10-05T00:00:00",
        "db": "VULMON",
        "id": "CVE-2020-16226"
      },
      {
        "date": "2020-09-07T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-008251"
      },
      {
        "date": "2020-10-05T18:15:13.133000",
        "db": "NVD",
        "id": "CVE-2020-16226"
      },
      {
        "date": "2020-09-01T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202009-074"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-09-17T00:00:00",
        "db": "ZDI",
        "id": "ZDI-20-1207"
      },
      {
        "date": "2020-10-22T00:00:00",
        "db": "VULMON",
        "id": "CVE-2020-16226"
      },
      {
        "date": "2022-09-26T08:55:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-008251"
      },
      {
        "date": "2020-10-22T18:59:52.350000",
        "db": "NVD",
        "id": "CVE-2020-16226"
      },
      {
        "date": "2022-09-28T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202009-074"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202009-074"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "of multiple Mitsubishi Electric products \u00a0TCP\u00a0 Session management flaw in protocol stack",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-008251"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Command execution",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202009-074"
      }
    ],
    "trust": 0.6
  }
}

var-202201-1491
Vulnerability from variot

Improper initialization vulnerability in MELSEC-F series FX3U-ENET Firmware version 1.16 and prior, FX3U-ENET-L Firmware version 1.16 and prior and FX3U-ENET-P502 Firmware version 1.16 and prior allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition in communication function of the product by sending specially crafted packets. Control by MELSEC-F series PLC is not affected by this vulnerability, but system reset is required for recovery.

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202201-1491",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "fx3u-enet-p502",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "1.16"
      },
      {
        "model": "fx3u-enet",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "1.16"
      },
      {
        "model": "fx3u-enet-l",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "1.16"
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-20613"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx3u-enet_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndIncluding": "1.16",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx3u-enet:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx3u-enet_firmware:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndIncluding": "1.16",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx3u-enet:-:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": false
              }
            ],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx3u-enet-l_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndIncluding": "1.16",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx3u-enet-l:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx3u-enet-l_firmware:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndIncluding": "1.16",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx3u-enet-l:-:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": false
              }
            ],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx3u-enet-p502_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndIncluding": "1.16",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx3u-enet-p502:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx3u-enet-p502_firmware:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndIncluding": "1.16",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:h:mitsubishielectric:fx3u-enet-p502:-:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": false
              }
            ],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-20613"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Mitsubishi Electric reported this vulnerability to CISA.",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202201-1074"
      }
    ],
    "trust": 0.6
  },
  "cve": "CVE-2021-20613",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2021-20613",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "HIGH",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "id": "CVE-2021-20613",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2021-20613",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202201-1074",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202201-1074"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-20613"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Improper initialization vulnerability in MELSEC-F series FX3U-ENET Firmware version 1.16 and prior, FX3U-ENET-L Firmware version 1.16 and prior and FX3U-ENET-P502 Firmware version 1.16 and prior allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition in communication function of the product by sending specially crafted packets. Control by MELSEC-F series PLC is not affected by this vulnerability, but system reset is required for recovery.",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-20613"
      }
    ],
    "trust": 1.0
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "JVN",
        "id": "JVNVU93268332",
        "trust": 1.6
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-22-013-07",
        "trust": 1.6
      },
      {
        "db": "NVD",
        "id": "CVE-2021-20613",
        "trust": 1.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202201-1074",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202201-1074"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-20613"
      }
    ]
  },
  "id": "VAR-202201-1491",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 1.0
  },
  "last_update_date": "2022-05-06T08:33:48.024000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Mitsubishi Electric MELSEC-F Series Security vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=177942"
      }
    ],
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202201-1074"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-665",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-20613"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.6,
        "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-013-07"
      },
      {
        "trust": 1.6,
        "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-024_en.pdf"
      },
      {
        "trust": 1.6,
        "url": "https://jvn.jp/vu/jvnvu93268332/index.html"
      },
      {
        "trust": 0.6,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-013-07"
      },
      {
        "trust": 0.6,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2021-20613"
      }
    ],
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202201-1074"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-20613"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202201-1074"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-20613"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-01-13T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202201-1074"
      },
      {
        "date": "2022-01-14T20:15:00",
        "db": "NVD",
        "id": "CVE-2021-20613"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-03-10T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202201-1074"
      },
      {
        "date": "2022-01-21T18:04:00",
        "db": "NVD",
        "id": "CVE-2021-20613"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202201-1074"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Mitsubishi Electric MELSEC-F Series Security hole",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202201-1074"
      }
    ],
    "trust": 0.6
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "other",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202201-1074"
      }
    ],
    "trust": 0.6
  }
}

var-202107-0288
Vulnerability from variot

NULL Pointer Dereference in MELSEC-F Series FX3U-ENET firmware version 1.14 and prior, FX3U-ENET-L firmware version 1.14 and prior and FX3U-ENET-P502 firmware version 1.14 and prior allows a remote unauthenticated attacker to cause a DoS condition in communication by sending specially crafted packets. Control by MELSEC-F series PLC is not affected and system reset is required for recovery. Made by Mitsubishi Electric MELSEC F series Ethernet Interface blocks NULL Pointer reference (CWE-476 , CVE-2021-20596) A vulnerability exists. This vulnerability information is provided by the developer for the purpose of making it known to product users. JPCERT/CC Report to JPCERT/CC Coordinated with the developers.If the product receives a malicious packet crafted by a remote third party, an error will occur and communication will interfere with service operation. (DoS) It may be in a state. In addition, by resetting the system, service operation is interrupted. (DoS) Recovery from the state is possible. According to the developer MELSEC F It has no effect on the control of the basic units of the series. Pillow is a Python-based image processing library. There is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements. Misubishi Electric Mitsubishi Electric MELSEC-F Series is a basic micro PLC with scalability of analog and communication functions for industrial control equipment of Mitsubishi Electric Corporation. Mitsubishi Electric MELSEC-F Series contains a code issue vulnerability that could cause a denial of service condition for communication with the product

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202107-0288",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "fx3u-enet-l",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "1.14"
      },
      {
        "model": "fx3u-enet",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "1.14"
      },
      {
        "model": "fx3u-enet-p502",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "1.14"
      },
      {
        "model": "fx3u-enet",
        "scope": "lte",
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": "-p502 firmware    1.14  and earlier"
      },
      {
        "model": "fx3u-enet",
        "scope": "lte",
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": "-l firmware    1.14  and earlier"
      },
      {
        "model": "fx3u-enet",
        "scope": "lte",
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": "firmware    1.14  and earlier"
      },
      {
        "model": "fx3u-enet-l",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": null
      },
      {
        "model": "fx3u-enet-p502",
        "scope": "lte",
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": "firmware    1.14  and earlier"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002007"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-20596"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx3u-enet-l_firmware:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndIncluding": "1.14",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx3u-enet-p502_firmware:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndIncluding": "1.14",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:o:mitsubishielectric:fx3u-enet_firmware:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndIncluding": "1.14",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-20596"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Mitsubishi Electric reported this vulnerability to CISA.",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202107-1555"
      }
    ],
    "trust": 0.6
  },
  "cve": "CVE-2021-20596",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "MEDIUM",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "VHN-378272",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "OTHER",
            "availabilityImpact": "High",
            "baseScore": 7.5,
            "baseSeverity": "High",
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "JVNDB-2021-002007",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2021-20596",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "OTHER",
            "id": "JVNDB-2021-002007",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202107-1555",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202104-975",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "VULHUB",
            "id": "VHN-378272",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-378272"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002007"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-20596"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202107-1555"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202104-975"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "NULL Pointer Dereference in MELSEC-F Series FX3U-ENET firmware version 1.14 and prior, FX3U-ENET-L firmware version 1.14 and prior and FX3U-ENET-P502 firmware version 1.14 and prior allows a remote unauthenticated attacker to cause a DoS condition in communication by sending specially crafted packets. Control by MELSEC-F series PLC is not affected and system reset is required for recovery. Made by Mitsubishi Electric MELSEC F series Ethernet Interface blocks NULL Pointer reference (CWE-476 , CVE-2021-20596) A vulnerability exists. This vulnerability information is provided by the developer for the purpose of making it known to product users. JPCERT/CC Report to JPCERT/CC Coordinated with the developers.If the product receives a malicious packet crafted by a remote third party, an error will occur and communication will interfere with service operation. (DoS) It may be in a state. In addition, by resetting the system, service operation is interrupted. (DoS) Recovery from the state is possible. According to the developer MELSEC F It has no effect on the control of the basic units of the series. Pillow is a Python-based image processing library. \nThere is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements. Misubishi Electric Mitsubishi Electric MELSEC-F Series is a basic micro PLC with scalability of analog and communication functions for industrial control equipment of Mitsubishi Electric Corporation. Mitsubishi Electric MELSEC-F Series contains a code issue vulnerability that could cause a denial of service condition for communication with the product",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-20596"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002007"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202104-975"
      },
      {
        "db": "VULHUB",
        "id": "VHN-378272"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-20596"
      }
    ],
    "trust": 2.34
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2021-20596",
        "trust": 2.6
      },
      {
        "db": "JVN",
        "id": "JVNVU94348759",
        "trust": 2.6
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-21-201-01",
        "trust": 2.5
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002007",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202107-1555",
        "trust": 0.7
      },
      {
        "db": "CS-HELP",
        "id": "SB2021072103",
        "trust": 0.6
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2021.2464",
        "trust": 0.6
      },
      {
        "db": "CS-HELP",
        "id": "SB2021041363",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202104-975",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-378272",
        "trust": 0.1
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-20596",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-378272"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-20596"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002007"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-20596"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202107-1555"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202104-975"
      }
    ]
  },
  "id": "VAR-202107-0288",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-378272"
      }
    ],
    "trust": 0.01
  },
  "last_update_date": "2023-12-18T11:30:53.251000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "MELSEC\u00a0F series Ethernet Denial of service in interface block DoS ) Vulnerability",
        "trust": 0.8,
        "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2021-006.pdf"
      },
      {
        "title": "MELSEC-F FX3U-ENET Fixes for code issue vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=157423"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002007"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202107-1555"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-476",
        "trust": 1.1
      },
      {
        "problemtype": "NULL Pointer dereference (CWE-476) [ Other ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-378272"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002007"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-20596"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.5,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-201-01"
      },
      {
        "trust": 1.8,
        "url": "https://jvn.jp/vu/jvnvu94348759/index.html"
      },
      {
        "trust": 1.8,
        "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-006_en.pdf"
      },
      {
        "trust": 0.8,
        "url": "http://jvn.jp/cert/jvnvu94348759"
      },
      {
        "trust": 0.6,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2021-20596"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2021.2464"
      },
      {
        "trust": 0.6,
        "url": "https://www.cybersecurity-help.cz/vdb/sb2021072103"
      },
      {
        "trust": 0.6,
        "url": "https://www.cybersecurity-help.cz/vdb/sb2021041363"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-378272"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-20596"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002007"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-20596"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202107-1555"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202104-975"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULHUB",
        "id": "VHN-378272"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-20596"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002007"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-20596"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202107-1555"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202104-975"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-07-22T00:00:00",
        "db": "VULHUB",
        "id": "VHN-378272"
      },
      {
        "date": "2021-07-22T00:00:00",
        "db": "VULMON",
        "id": "CVE-2021-20596"
      },
      {
        "date": "2021-07-21T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-002007"
      },
      {
        "date": "2021-07-22T12:15:07.787000",
        "db": "NVD",
        "id": "CVE-2021-20596"
      },
      {
        "date": "2021-07-20T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202107-1555"
      },
      {
        "date": "2021-04-13T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202104-975"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-08-02T00:00:00",
        "db": "VULHUB",
        "id": "VHN-378272"
      },
      {
        "date": "2021-07-22T00:00:00",
        "db": "VULMON",
        "id": "CVE-2021-20596"
      },
      {
        "date": "2021-07-26T05:48:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-002007"
      },
      {
        "date": "2021-08-02T14:25:16.287000",
        "db": "NVD",
        "id": "CVE-2021-20596"
      },
      {
        "date": "2021-08-03T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202107-1555"
      },
      {
        "date": "2021-04-14T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202104-975"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202107-1555"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Made by Mitsubishi Electric \u00a0MELSEC\u00a0F\u00a0 series \u00a0Ethernet\u00a0 In the interface block \u00a0NULL\u00a0 Pointer reference vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-002007"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "code problem",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202107-1555"
      }
    ],
    "trust": 0.6
  }
}