Search criteria
45 vulnerabilities found for go-rt-ac750_firmware by dlink
FKIE_CVE-2024-27683
Vulnerability from fkie_nvd - Published: 2024-04-11 01:25 - Updated: 2025-06-17 20:55
Severity ?
Summary
D-Link Go-RT-AC750 GORTAC750_A1_FW_v101b03 contains a stack-based buffer overflow via the function hnap_main. An attacker can send a POST request to trigger the vulnerablilify.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| dlink | go-rt-ac750_firmware | 101b03 | |
| dlink | go-rt-ac750 | a1 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:dlink:go-rt-ac750_firmware:101b03:*:*:*:*:*:*:*",
"matchCriteriaId": "11857770-E809-483A-993F-1C827428B334",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:dlink:go-rt-ac750:a1:*:*:*:*:*:*:*",
"matchCriteriaId": "FD359363-0BD0-49DF-99B3-1F6A2CED8378",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "D-Link Go-RT-AC750 GORTAC750_A1_FW_v101b03 contains a stack-based buffer overflow via the function hnap_main. An attacker can send a POST request to trigger the vulnerablilify."
},
{
"lang": "es",
"value": "D-Link Go-RT-AC750 GORTAC750_A1_FW_v101b03 contiene un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria a trav\u00e9s de la funci\u00f3n hnap_main. Un atacante puede enviar una solicitud POST para activar la vulnerabilidad."
}
],
"id": "CVE-2024-27683",
"lastModified": "2025-06-17T20:55:49.377",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2024-04-11T01:25:05.340",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Permissions Required"
],
"url": "https://drive.google.com/file/d/18RhbBnaD_kH16Y6C-7TpSSPUmYKKyU_k/view"
},
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
],
"url": "https://gist.github.com/sunwithmoon/428c3871482a600382fec0a1994a518b"
},
{
"source": "cve@mitre.org",
"tags": [
"Product"
],
"url": "https://www.dlink.com/en/security-bulletin/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Permissions Required"
],
"url": "https://drive.google.com/file/d/18RhbBnaD_kH16Y6C-7TpSSPUmYKKyU_k/view"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://gist.github.com/sunwithmoon/428c3871482a600382fec0a1994a518b"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Product"
],
"url": "https://www.dlink.com/en/security-bulletin/"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-121"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2024-27684
Vulnerability from fkie_nvd - Published: 2024-03-04 14:15 - Updated: 2025-05-02 19:32
Severity ?
Summary
A Cross-site scripting (XSS) vulnerability in dlapn.cgi, dldongle.cgi, dlcfg.cgi, fwup.cgi and seama.cgi in D-Link GORTAC750_A1_FW_v101b03 allows remote attackers to inject arbitrary web script or HTML via the url parameter.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| dlink | go-rt-ac750_firmware | 101b03 | |
| dlink | go-rt-ac750 | a1 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:dlink:go-rt-ac750_firmware:101b03:*:*:*:*:*:*:*",
"matchCriteriaId": "11857770-E809-483A-993F-1C827428B334",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:dlink:go-rt-ac750:a1:*:*:*:*:*:*:*",
"matchCriteriaId": "FD359363-0BD0-49DF-99B3-1F6A2CED8378",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A Cross-site scripting (XSS) vulnerability in dlapn.cgi, dldongle.cgi, dlcfg.cgi, fwup.cgi and seama.cgi in D-Link GORTAC750_A1_FW_v101b03 allows remote attackers to inject arbitrary web script or HTML via the url parameter."
},
{
"lang": "es",
"value": "Una vulnerabilidad de Cross-Site Scripting (XSS) en dlapn.cgi, dldongle.cgi, dlcfg.cgi, fwup.cgi y seama.cgi en D-Link GORTAC750_A1_FW_v101b03 permite a atacantes remotos inyectar script web o HTML arbitrarios a trav\u00e9s del par\u00e1metro url."
}
],
"id": "CVE-2024-27684",
"lastModified": "2025-05-02T19:32:50.587",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 2.7,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2024-03-04T14:15:41.587",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Permissions Required"
],
"url": "https://drive.google.com/file/d/1qu4iBQGeAwolTXjVOTXsAAusSHo2ie-Y/view"
},
{
"source": "cve@mitre.org",
"tags": [
"Product"
],
"url": "https://www.dlink.com/en/security-bulletin/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Permissions Required"
],
"url": "https://drive.google.com/file/d/1qu4iBQGeAwolTXjVOTXsAAusSHo2ie-Y/view"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Product"
],
"url": "https://www.dlink.com/en/security-bulletin/"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2024-22853
Vulnerability from fkie_nvd - Published: 2024-02-06 02:15 - Updated: 2025-06-20 21:15
Severity ?
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
D-LINK Go-RT-AC750 GORTAC750_A1_FW_v101b03 has a hardcoded password for the Alphanetworks account, which allows remote attackers to obtain root access via a telnet session.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://github.com/Beckaf/vunl/blob/main/D-Link/AC750/2/2.md | Exploit, Third Party Advisory | |
| cve@mitre.org | https://www.dlink.com/en/security-bulletin/ | Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://github.com/Beckaf/vunl/blob/main/D-Link/AC750/2/2.md | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.dlink.com/en/security-bulletin/ | Vendor Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| dlink | go-rt-ac750_firmware | 101b03 | |
| dlink | go-rt-ac750 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:dlink:go-rt-ac750_firmware:101b03:*:*:*:*:*:*:*",
"matchCriteriaId": "11857770-E809-483A-993F-1C827428B334",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:dlink:go-rt-ac750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EE067003-B0B5-4419-8BB3-A31C015276D0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "D-LINK Go-RT-AC750 GORTAC750_A1_FW_v101b03 has a hardcoded password for the Alphanetworks account, which allows remote attackers to obtain root access via a telnet session."
},
{
"lang": "es",
"value": "D-LINK Go-RT-AC750 GORTAC750_A1_FW_v101b03 tiene una contrase\u00f1a codificada para la cuenta Alphanetworks, que permite a atacantes remotos obtener acceso root a trav\u00e9s de una sesi\u00f3n de telnet."
}
],
"id": "CVE-2024-22853",
"lastModified": "2025-06-20T21:15:21.023",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2024-02-06T02:15:08.757",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://github.com/Beckaf/vunl/blob/main/D-Link/AC750/2/2.md"
},
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://www.dlink.com/en/security-bulletin/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://github.com/Beckaf/vunl/blob/main/D-Link/AC750/2/2.md"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.dlink.com/en/security-bulletin/"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-798"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-798"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2024-22852
Vulnerability from fkie_nvd - Published: 2024-02-06 02:15 - Updated: 2025-05-15 20:15
Severity ?
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
D-Link Go-RT-AC750 GORTAC750_A1_FW_v101b03 contains a stack-based buffer overflow via the function genacgi_main. This vulnerability allows attackers to enable telnet service via a specially crafted payload.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://github.com/Beckaf/vunl/blob/main/D-Link/AC750/1/1.md | Exploit, Third Party Advisory | |
| cve@mitre.org | https://www.dlink.com/en/security-bulletin/ | Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://github.com/Beckaf/vunl/blob/main/D-Link/AC750/1/1.md | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.dlink.com/en/security-bulletin/ | Vendor Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| dlink | go-rt-ac750_firmware | 101b03 | |
| dlink | go-rt-ac750 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:dlink:go-rt-ac750_firmware:101b03:*:*:*:*:*:*:*",
"matchCriteriaId": "11857770-E809-483A-993F-1C827428B334",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:dlink:go-rt-ac750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EE067003-B0B5-4419-8BB3-A31C015276D0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "D-Link Go-RT-AC750 GORTAC750_A1_FW_v101b03 contains a stack-based buffer overflow via the function genacgi_main. This vulnerability allows attackers to enable telnet service via a specially crafted payload."
},
{
"lang": "es",
"value": "D-Link Go-RT-AC750 GORTAC750_A1_FW_v101b03 contiene un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria a trav\u00e9s de la funci\u00f3n genacgi_main. Esta vulnerabilidad permite a los atacantes habilitar el servicio telnet a trav\u00e9s de un payload especialmente manipulado."
}
],
"id": "CVE-2024-22852",
"lastModified": "2025-05-15T20:15:43.533",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2024-02-06T02:15:08.663",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://github.com/Beckaf/vunl/blob/main/D-Link/AC750/1/1.md"
},
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://www.dlink.com/en/security-bulletin/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://github.com/Beckaf/vunl/blob/main/D-Link/AC750/1/1.md"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.dlink.com/en/security-bulletin/"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2024-22916
Vulnerability from fkie_nvd - Published: 2024-01-16 22:15 - Updated: 2024-11-21 08:56
Severity ?
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
In D-LINK Go-RT-AC750 v101b03, the sprintf function in the sub_40E700 function within the cgibin is susceptible to stack overflow.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://kee02p.github.io/2024/01/13/CVE-2024-22916/ | Exploit, Third Party Advisory | |
| cve@mitre.org | https://www.dlink.com/en/security-bulletin/ | Product | |
| af854a3a-2127-422b-91ae-364da2661108 | https://kee02p.github.io/2024/01/13/CVE-2024-22916/ | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.dlink.com/en/security-bulletin/ | Product |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| dlink | go-rt-ac750_firmware | 101b03 | |
| dlink | go-rt-ac750 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:dlink:go-rt-ac750_firmware:101b03:*:*:*:*:*:*:*",
"matchCriteriaId": "11857770-E809-483A-993F-1C827428B334",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:dlink:go-rt-ac750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EE067003-B0B5-4419-8BB3-A31C015276D0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "In D-LINK Go-RT-AC750 v101b03, the sprintf function in the sub_40E700 function within the cgibin is susceptible to stack overflow."
},
{
"lang": "es",
"value": "En D-LINK Go-RT-AC750 v101b03, la funci\u00f3n sprintf en la funci\u00f3n sub_40E700 dentro de cgibin es susceptible al desbordamiento de pila."
}
],
"id": "CVE-2024-22916",
"lastModified": "2024-11-21T08:56:47.923",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2024-01-16T22:15:46.613",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://kee02p.github.io/2024/01/13/CVE-2024-22916/"
},
{
"source": "cve@mitre.org",
"tags": [
"Product"
],
"url": "https://www.dlink.com/en/security-bulletin/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://kee02p.github.io/2024/01/13/CVE-2024-22916/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Product"
],
"url": "https://www.dlink.com/en/security-bulletin/"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2023-48842
Vulnerability from fkie_nvd - Published: 2023-12-01 16:15 - Updated: 2025-06-03 03:15
Severity ?
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
D-Link Go-RT-AC750 revA_v101b03 was discovered to contain a command injection vulnerability via the service parameter at hedwig.cgi.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| dlink | go-rt-ac750_firmware | 101b03 | |
| dlink | go-rt-ac750 | revision_a |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:dlink:go-rt-ac750_firmware:101b03:*:*:*:*:*:*:*",
"matchCriteriaId": "11857770-E809-483A-993F-1C827428B334",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:dlink:go-rt-ac750:revision_a:*:*:*:*:*:*:*",
"matchCriteriaId": "426BE281-6336-4A4E-892B-CE8BBCA8ABF7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "D-Link Go-RT-AC750 revA_v101b03 was discovered to contain a command injection vulnerability via the service parameter at hedwig.cgi."
},
{
"lang": "es",
"value": "Se descubri\u00f3 que D-Link Go-RT-AC750 revA_v101b03 conten\u00eda una vulnerabilidad de inyecci\u00f3n de comandos a trav\u00e9s del par\u00e1metro de servicio en hedwig.cgi."
}
],
"id": "CVE-2023-48842",
"lastModified": "2025-06-03T03:15:25.490",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2023-12-01T16:15:07.550",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit"
],
"url": "https://drive.google.com/file/d/1y5om__f2SAhNmcPqDxC_SRTvJVAWwPcH/view?usp=drive_link"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit"
],
"url": "https://drive.google.com/file/d/1y5om__f2SAhNmcPqDxC_SRTvJVAWwPcH/view?usp=drive_link"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-77"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-78"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2023-34800
Vulnerability from fkie_nvd - Published: 2023-06-15 21:15 - Updated: 2024-12-16 20:15
Severity ?
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
D-Link Go-RT-AC750 revA_v101b03 was discovered to contain a command injection vulnerability via the service parameter at genacgi_main.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://github.com/Tyaoo/IoT-Vuls/blob/main/dlink/Go-RT-AC750/vul.md | Exploit, Third Party Advisory | |
| cve@mitre.org | https://www.dlink.com/en/security-bulletin/ | Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://github.com/Tyaoo/IoT-Vuls/blob/main/dlink/Go-RT-AC750/vul.md | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.dlink.com/en/security-bulletin/ | Vendor Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| dlink | go-rt-ac750_firmware | reva_1.01b03 | |
| dlink | go-rt-ac750 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:dlink:go-rt-ac750_firmware:reva_1.01b03:*:*:*:*:*:*:*",
"matchCriteriaId": "1B975BD2-5567-4B7A-BC8D-633B5D446556",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:dlink:go-rt-ac750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EE067003-B0B5-4419-8BB3-A31C015276D0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "D-Link Go-RT-AC750 revA_v101b03 was discovered to contain a command injection vulnerability via the service parameter at genacgi_main."
},
{
"lang": "es",
"value": "Se descubri\u00f3 que D-Link Go-RT-AC750 revA_v101b03 contiene una vulnerabilidad de inyecci\u00f3n de comandos a trav\u00e9s del par\u00e1metro service en genacgi_main."
}
],
"id": "CVE-2023-34800",
"lastModified": "2024-12-16T20:15:07.120",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2023-06-15T21:15:09.677",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://github.com/Tyaoo/IoT-Vuls/blob/main/dlink/Go-RT-AC750/vul.md"
},
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://www.dlink.com/en/security-bulletin/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://github.com/Tyaoo/IoT-Vuls/blob/main/dlink/Go-RT-AC750/vul.md"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.dlink.com/en/security-bulletin/"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-78"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-78"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2023-26822
Vulnerability from fkie_nvd - Published: 2023-04-01 23:15 - Updated: 2025-02-11 18:15
Severity ?
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
D-Link Go-RT-AC750 revA_v101b03 was discovered to contain a command injection vulnerability via the service parameter at soapcgi.main.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://github.com/yzskyt/Vuln/blob/main/Go-RT-AC750/Go-RT-AC750.md | Exploit, Third Party Advisory | |
| cve@mitre.org | https://www.dlink.com/en/security-bulletin/ | Not Applicable | |
| af854a3a-2127-422b-91ae-364da2661108 | https://github.com/yzskyt/Vuln/blob/main/Go-RT-AC750/Go-RT-AC750.md | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.dlink.com/en/security-bulletin/ | Not Applicable |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| dlink | go-rt-ac750_firmware | reva_v101b03 | |
| dlink | go-rt-ac750 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:dlink:go-rt-ac750_firmware:reva_v101b03:*:*:*:*:*:*:*",
"matchCriteriaId": "BF67C4BB-000A-4657-9BA0-8DC944AC20B3",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:dlink:go-rt-ac750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EE067003-B0B5-4419-8BB3-A31C015276D0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "D-Link Go-RT-AC750 revA_v101b03 was discovered to contain a command injection vulnerability via the service parameter at soapcgi.main."
}
],
"id": "CVE-2023-26822",
"lastModified": "2025-02-11T18:15:24.467",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2023-04-01T23:15:07.060",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://github.com/yzskyt/Vuln/blob/main/Go-RT-AC750/Go-RT-AC750.md"
},
{
"source": "cve@mitre.org",
"tags": [
"Not Applicable"
],
"url": "https://www.dlink.com/en/security-bulletin/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://github.com/yzskyt/Vuln/blob/main/Go-RT-AC750/Go-RT-AC750.md"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Not Applicable"
],
"url": "https://www.dlink.com/en/security-bulletin/"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-77"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-77"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2022-37056
Vulnerability from fkie_nvd - Published: 2022-08-28 17:15 - Updated: 2025-12-09 19:15
Severity ?
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
D-Link GO-RT-AC750 GORTAC750_revA_v101b03 and GO-RT-AC750_revB_FWv200b02 is vulnerable to Command Injection via /cgibin, hnap_main,
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://drive.google.com/file/d/127tqMUvAxQ4OlycoSNtcP0x2282Y75GJ/view?usp=sharing | Exploit, Patch, Third Party Advisory | |
| cve@mitre.org | https://supportannouncement.us.dlink.com/security/publication.aspx?name=SAP10308 | Vendor Advisory | |
| cve@mitre.org | https://www.dlink.com/en/security-bulletin/ | Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://drive.google.com/file/d/127tqMUvAxQ4OlycoSNtcP0x2282Y75GJ/view?usp=sharing | Exploit, Patch, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.dlink.com/en/security-bulletin/ | Vendor Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| dlink | go-rt-ac750_firmware | 2.00b02 | |
| dlink | go-rt-ac750 | revision_b | |
| dlink | go-rt-ac750_firmware | 1.01b03 | |
| dlink | go-rt-ac750 | revision_a |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:dlink:go-rt-ac750_firmware:2.00b02:*:*:*:*:*:*:*",
"matchCriteriaId": "2E9270A7-6413-46E8-840E-EE019B13BB2C",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:dlink:go-rt-ac750:revision_b:*:*:*:*:*:*:*",
"matchCriteriaId": "5F4EF05A-EF25-4E60-8A08-9C0CDD9244EF",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:dlink:go-rt-ac750_firmware:1.01b03:*:*:*:*:*:*:*",
"matchCriteriaId": "E3E08E3B-C349-4653-80BE-0E4D4B453A34",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:dlink:go-rt-ac750:revision_a:*:*:*:*:*:*:*",
"matchCriteriaId": "426BE281-6336-4A4E-892B-CE8BBCA8ABF7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "D-Link GO-RT-AC750 GORTAC750_revA_v101b03 and GO-RT-AC750_revB_FWv200b02 is vulnerable to Command Injection via /cgibin, hnap_main,"
},
{
"lang": "es",
"value": "D-Link GO-RT-AC750 versiones GORTAC750_revA_v101b03 y GO-RT-AC750_revB_FWv200b02, son vulnerables a una inyecci\u00f3n de comandos por medio de /cgibin, hnap_main,"
}
],
"id": "CVE-2022-37056",
"lastModified": "2025-12-09T19:15:26.943",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2022-08-28T17:15:08.413",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Patch",
"Third Party Advisory"
],
"url": "https://drive.google.com/file/d/127tqMUvAxQ4OlycoSNtcP0x2282Y75GJ/view?usp=sharing"
},
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://supportannouncement.us.dlink.com/security/publication.aspx?name=SAP10308"
},
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://www.dlink.com/en/security-bulletin/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Patch",
"Third Party Advisory"
],
"url": "https://drive.google.com/file/d/127tqMUvAxQ4OlycoSNtcP0x2282Y75GJ/view?usp=sharing"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.dlink.com/en/security-bulletin/"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-78"
}
],
"source": "cve@mitre.org",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-78"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2022-37055
Vulnerability from fkie_nvd - Published: 2022-08-28 17:15 - Updated: 2025-12-09 19:15
Severity ?
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
D-Link Go-RT-AC750 GORTAC750_revA_v101b03 and GO-RT-AC750_revB_FWv200b02 are vulnerable to Buffer Overflow via cgibin, hnap_main,
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://drive.google.com/file/d/1hmIk0jQoex4QDyjIUg_6yxi-J6ROCh8S/view?usp=sharing | Exploit, Patch, Third Party Advisory | |
| cve@mitre.org | https://supportannouncement.us.dlink.com/security/publication.aspx?name=SAP10308 | Vendor Advisory | |
| cve@mitre.org | https://www.dlink.com/en/security-bulletin/ | Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://drive.google.com/file/d/1hmIk0jQoex4QDyjIUg_6yxi-J6ROCh8S/view?usp=sharing | Exploit, Patch, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.dlink.com/en/security-bulletin/ | Vendor Advisory | |
| 134c704f-9b21-4f2e-91b3-4a467353bcc0 | https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2022-37055 | US Government Resource | |
| 134c704f-9b21-4f2e-91b3-4a467353bcc0 | https://www.fortiguard.com/outbreak-alert/d-link-multiple-devices-attack | Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| dlink | go-rt-ac750_firmware | 2.00b02 | |
| dlink | go-rt-ac750 | revision_b | |
| dlink | go-rt-ac750_firmware | 1.01b03 | |
| dlink | go-rt-ac750 | revision_a |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:dlink:go-rt-ac750_firmware:2.00b02:*:*:*:*:*:*:*",
"matchCriteriaId": "2E9270A7-6413-46E8-840E-EE019B13BB2C",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:dlink:go-rt-ac750:revision_b:*:*:*:*:*:*:*",
"matchCriteriaId": "5F4EF05A-EF25-4E60-8A08-9C0CDD9244EF",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:dlink:go-rt-ac750_firmware:1.01b03:*:*:*:*:*:*:*",
"matchCriteriaId": "E3E08E3B-C349-4653-80BE-0E4D4B453A34",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:dlink:go-rt-ac750:revision_a:*:*:*:*:*:*:*",
"matchCriteriaId": "426BE281-6336-4A4E-892B-CE8BBCA8ABF7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "D-Link Go-RT-AC750 GORTAC750_revA_v101b03 and GO-RT-AC750_revB_FWv200b02 are vulnerable to Buffer Overflow via cgibin, hnap_main,"
},
{
"lang": "es",
"value": "D-Link Go-RT-AC750 versiones GORTAC750_revA_v101b03 y GO-RT-AC750_revB_FWv200b02, son vulnerables al desbordamiento del b\u00fafer por medio de cgibin, hnap_main,"
}
],
"id": "CVE-2022-37055",
"lastModified": "2025-12-09T19:15:22.987",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2022-08-28T17:15:08.363",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Patch",
"Third Party Advisory"
],
"url": "https://drive.google.com/file/d/1hmIk0jQoex4QDyjIUg_6yxi-J6ROCh8S/view?usp=sharing"
},
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://supportannouncement.us.dlink.com/security/publication.aspx?name=SAP10308"
},
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://www.dlink.com/en/security-bulletin/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Patch",
"Third Party Advisory"
],
"url": "https://drive.google.com/file/d/1hmIk0jQoex4QDyjIUg_6yxi-J6ROCh8S/view?usp=sharing"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.dlink.com/en/security-bulletin/"
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"tags": [
"US Government Resource"
],
"url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2022-37055"
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"tags": [
"Third Party Advisory"
],
"url": "https://www.fortiguard.com/outbreak-alert/d-link-multiple-devices-attack"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-120"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-120"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2022-37057
Vulnerability from fkie_nvd - Published: 2022-08-28 16:15 - Updated: 2025-12-09 19:15
Severity ?
Summary
D-Link Go-RT-AC750 GORTAC750_revA_v101b03 and GO-RT-AC750_revB_FWv200b02 are vulnerable to Command Injection via cgibin, ssdpcgi_main.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://drive.google.com/file/d/1_UUpraFTxxB97ujrgVLQZXQ8Q8M58BAF/view?usp=sharing | Exploit, Patch, Third Party Advisory | |
| cve@mitre.org | https://supportannouncement.us.dlink.com/security/publication.aspx?name=SAP10308 | Vendor Advisory | |
| cve@mitre.org | https://www.dlink.com/en/security-bulletin/ | Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://drive.google.com/file/d/1_UUpraFTxxB97ujrgVLQZXQ8Q8M58BAF/view?usp=sharing | Exploit, Patch, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.dlink.com/en/security-bulletin/ | Vendor Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| dlink | go-rt-ac750_firmware | 2.00b02 | |
| dlink | go-rt-ac750 | revision_b | |
| dlink | go-rt-ac750_firmware | 1.01b03 | |
| dlink | go-rt-ac750 | revision_a |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:dlink:go-rt-ac750_firmware:2.00b02:*:*:*:*:*:*:*",
"matchCriteriaId": "2E9270A7-6413-46E8-840E-EE019B13BB2C",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:dlink:go-rt-ac750:revision_b:*:*:*:*:*:*:*",
"matchCriteriaId": "5F4EF05A-EF25-4E60-8A08-9C0CDD9244EF",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:dlink:go-rt-ac750_firmware:1.01b03:*:*:*:*:*:*:*",
"matchCriteriaId": "E3E08E3B-C349-4653-80BE-0E4D4B453A34",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:dlink:go-rt-ac750:revision_a:*:*:*:*:*:*:*",
"matchCriteriaId": "426BE281-6336-4A4E-892B-CE8BBCA8ABF7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "D-Link Go-RT-AC750 GORTAC750_revA_v101b03 and GO-RT-AC750_revB_FWv200b02 are vulnerable to Command Injection via cgibin, ssdpcgi_main."
},
{
"lang": "es",
"value": "D-Link Go-RT-AC750 versiones GORTAC750_revA_v101b03 y GO-RT-AC750_revB_FWv200b02, son vulnerables a una Inyecci\u00f3n de Comandos por medio de cgibin, ssdpcgi_main."
}
],
"id": "CVE-2022-37057",
"lastModified": "2025-12-09T19:15:29.677",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2022-08-28T16:15:09.123",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Patch",
"Third Party Advisory"
],
"url": "https://drive.google.com/file/d/1_UUpraFTxxB97ujrgVLQZXQ8Q8M58BAF/view?usp=sharing"
},
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://supportannouncement.us.dlink.com/security/publication.aspx?name=SAP10308"
},
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://www.dlink.com/en/security-bulletin/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Patch",
"Third Party Advisory"
],
"url": "https://drive.google.com/file/d/1_UUpraFTxxB97ujrgVLQZXQ8Q8M58BAF/view?usp=sharing"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.dlink.com/en/security-bulletin/"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-78"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
CVE-2024-27683 (GCVE-0-2024-27683)
Vulnerability from cvelistv5 – Published: 2024-03-21 00:00 – Updated: 2024-08-14 19:07
VLAI?
Summary
D-Link Go-RT-AC750 GORTAC750_A1_FW_v101b03 contains a stack-based buffer overflow via the function hnap_main. An attacker can send a POST request to trigger the vulnerablilify.
Severity ?
9.8 (Critical)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T00:34:52.538Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.dlink.com/en/security-bulletin/"
},
{
"tags": [
"x_transferred"
],
"url": "https://drive.google.com/file/d/18RhbBnaD_kH16Y6C-7TpSSPUmYKKyU_k/view"
},
{
"tags": [
"x_transferred"
],
"url": "https://gist.github.com/sunwithmoon/428c3871482a600382fec0a1994a518b"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:dlink:go-rt-ac750_firmware:101b03:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "go-rt-ac750_firmware",
"vendor": "dlink",
"versions": [
{
"status": "affected",
"version": "101b03"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-27683",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-14T19:03:53.243547Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-14T19:07:30.354Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "D-Link Go-RT-AC750 GORTAC750_A1_FW_v101b03 contains a stack-based buffer overflow via the function hnap_main. An attacker can send a POST request to trigger the vulnerablilify."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-21T11:32:39.559169",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.dlink.com/en/security-bulletin/"
},
{
"url": "https://drive.google.com/file/d/18RhbBnaD_kH16Y6C-7TpSSPUmYKKyU_k/view"
},
{
"url": "https://gist.github.com/sunwithmoon/428c3871482a600382fec0a1994a518b"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-27683",
"datePublished": "2024-03-21T00:00:00",
"dateReserved": "2024-02-26T00:00:00",
"dateUpdated": "2024-08-14T19:07:30.354Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-27684 (GCVE-0-2024-27684)
Vulnerability from cvelistv5 – Published: 2024-03-04 00:00 – Updated: 2024-08-16 15:53
VLAI?
Summary
A Cross-site scripting (XSS) vulnerability in dlapn.cgi, dldongle.cgi, dlcfg.cgi, fwup.cgi and seama.cgi in D-Link GORTAC750_A1_FW_v101b03 allows remote attackers to inject arbitrary web script or HTML via the url parameter.
Severity ?
6.1 (Medium)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T00:34:52.524Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.dlink.com/en/security-bulletin/"
},
{
"tags": [
"x_transferred"
],
"url": "https://drive.google.com/file/d/1qu4iBQGeAwolTXjVOTXsAAusSHo2ie-Y/view"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:dlink:gortac750_a1_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "gortac750_a1_firmware",
"vendor": "dlink",
"versions": [
{
"status": "affected",
"version": "101b03"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-27684",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-03-04T16:35:29.279350Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-16T15:53:22.513Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A Cross-site scripting (XSS) vulnerability in dlapn.cgi, dldongle.cgi, dlcfg.cgi, fwup.cgi and seama.cgi in D-Link GORTAC750_A1_FW_v101b03 allows remote attackers to inject arbitrary web script or HTML via the url parameter."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-04T13:47:37.638773",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.dlink.com/en/security-bulletin/"
},
{
"url": "https://drive.google.com/file/d/1qu4iBQGeAwolTXjVOTXsAAusSHo2ie-Y/view"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-27684",
"datePublished": "2024-03-04T00:00:00",
"dateReserved": "2024-02-26T00:00:00",
"dateUpdated": "2024-08-16T15:53:22.513Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-22852 (GCVE-0-2024-22852)
Vulnerability from cvelistv5 – Published: 2024-02-06 00:00 – Updated: 2025-05-15 19:45
VLAI?
Summary
D-Link Go-RT-AC750 GORTAC750_A1_FW_v101b03 contains a stack-based buffer overflow via the function genacgi_main. This vulnerability allows attackers to enable telnet service via a specially crafted payload.
Severity ?
9.8 (Critical)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T22:51:11.136Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.dlink.com/en/security-bulletin/"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/Beckaf/vunl/blob/main/D-Link/AC750/1/1.md"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-22852",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-08T15:58:45.552998Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787 Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-05-15T19:45:54.686Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "D-Link Go-RT-AC750 GORTAC750_A1_FW_v101b03 contains a stack-based buffer overflow via the function genacgi_main. This vulnerability allows attackers to enable telnet service via a specially crafted payload."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-02-06T01:18:42.565Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.dlink.com/en/security-bulletin/"
},
{
"url": "https://github.com/Beckaf/vunl/blob/main/D-Link/AC750/1/1.md"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-22852",
"datePublished": "2024-02-06T00:00:00.000Z",
"dateReserved": "2024-01-11T00:00:00.000Z",
"dateUpdated": "2025-05-15T19:45:54.686Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-22853 (GCVE-0-2024-22853)
Vulnerability from cvelistv5 – Published: 2024-02-06 00:00 – Updated: 2025-06-20 20:13
VLAI?
Summary
D-LINK Go-RT-AC750 GORTAC750_A1_FW_v101b03 has a hardcoded password for the Alphanetworks account, which allows remote attackers to obtain root access via a telnet session.
Severity ?
9.8 (Critical)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T22:51:11.111Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.dlink.com/en/security-bulletin/"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/Beckaf/vunl/blob/main/D-Link/AC750/2/2.md"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-22853",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-02-06T15:37:40.936496Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798 Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-20T20:13:39.786Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "D-LINK Go-RT-AC750 GORTAC750_A1_FW_v101b03 has a hardcoded password for the Alphanetworks account, which allows remote attackers to obtain root access via a telnet session."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-02-06T01:18:48.256Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.dlink.com/en/security-bulletin/"
},
{
"url": "https://github.com/Beckaf/vunl/blob/main/D-Link/AC750/2/2.md"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-22853",
"datePublished": "2024-02-06T00:00:00.000Z",
"dateReserved": "2024-01-11T00:00:00.000Z",
"dateUpdated": "2025-06-20T20:13:39.786Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-22916 (GCVE-0-2024-22916)
Vulnerability from cvelistv5 – Published: 2024-01-16 00:00 – Updated: 2024-08-29 19:53
VLAI?
Summary
In D-LINK Go-RT-AC750 v101b03, the sprintf function in the sub_40E700 function within the cgibin is susceptible to stack overflow.
Severity ?
9.8 (Critical)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T22:51:11.195Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.dlink.com/en/security-bulletin/"
},
{
"tags": [
"x_transferred"
],
"url": "https://kee02p.github.io/2024/01/13/CVE-2024-22916/"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:dlink:go-rt-ac750_firmware:101b03:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "go-rt-ac750_firmware",
"vendor": "dlink",
"versions": [
{
"status": "affected",
"version": "101b03"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-22916",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-29T19:45:54.326640Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787 Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-29T19:53:52.941Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "In D-LINK Go-RT-AC750 v101b03, the sprintf function in the sub_40E700 function within the cgibin is susceptible to stack overflow."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-01-16T22:07:20.612751",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.dlink.com/en/security-bulletin/"
},
{
"url": "https://kee02p.github.io/2024/01/13/CVE-2024-22916/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-22916",
"datePublished": "2024-01-16T00:00:00",
"dateReserved": "2024-01-11T00:00:00",
"dateUpdated": "2024-08-29T19:53:52.941Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-48842 (GCVE-0-2023-48842)
Vulnerability from cvelistv5 – Published: 2023-12-01 00:00 – Updated: 2025-06-03 02:24
VLAI?
Summary
D-Link Go-RT-AC750 revA_v101b03 was discovered to contain a command injection vulnerability via the service parameter at hedwig.cgi.
Severity ?
9.8 (Critical)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T21:46:28.238Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://drive.google.com/file/d/1y5om__f2SAhNmcPqDxC_SRTvJVAWwPcH/view?usp=drive_link"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2023-48842",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-03T02:23:28.359315Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-03T02:24:53.955Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "D-Link Go-RT-AC750 revA_v101b03 was discovered to contain a command injection vulnerability via the service parameter at hedwig.cgi."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-01T15:16:04.709Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://drive.google.com/file/d/1y5om__f2SAhNmcPqDxC_SRTvJVAWwPcH/view?usp=drive_link"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-48842",
"datePublished": "2023-12-01T00:00:00.000Z",
"dateReserved": "2023-11-20T00:00:00.000Z",
"dateUpdated": "2025-06-03T02:24:53.955Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-34800 (GCVE-0-2023-34800)
Vulnerability from cvelistv5 – Published: 2023-06-15 00:00 – Updated: 2024-12-16 19:45
VLAI?
Summary
D-Link Go-RT-AC750 revA_v101b03 was discovered to contain a command injection vulnerability via the service parameter at genacgi_main.
Severity ?
9.8 (Critical)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T16:17:04.339Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.dlink.com/en/security-bulletin/"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/Tyaoo/IoT-Vuls/blob/main/dlink/Go-RT-AC750/vul.md"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2023-34800",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-12-16T19:42:04.175887Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-12-16T19:45:16.331Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "D-Link Go-RT-AC750 revA_v101b03 was discovered to contain a command injection vulnerability via the service parameter at genacgi_main."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-06-15T00:00:00",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.dlink.com/en/security-bulletin/"
},
{
"url": "https://github.com/Tyaoo/IoT-Vuls/blob/main/dlink/Go-RT-AC750/vul.md"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-34800",
"datePublished": "2023-06-15T00:00:00",
"dateReserved": "2023-06-07T00:00:00",
"dateUpdated": "2024-12-16T19:45:16.331Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-26822 (GCVE-0-2023-26822)
Vulnerability from cvelistv5 – Published: 2023-04-01 00:00 – Updated: 2025-02-11 17:12
VLAI?
Summary
D-Link Go-RT-AC750 revA_v101b03 was discovered to contain a command injection vulnerability via the service parameter at soapcgi.main.
Severity ?
9.8 (Critical)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T11:53:54.522Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.dlink.com/en/security-bulletin/"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/yzskyt/Vuln/blob/main/Go-RT-AC750/Go-RT-AC750.md"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2023-26822",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-11T17:12:22.889168Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-11T17:12:28.548Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "D-Link Go-RT-AC750 revA_v101b03 was discovered to contain a command injection vulnerability via the service parameter at soapcgi.main."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-04-01T00:00:00.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.dlink.com/en/security-bulletin/"
},
{
"url": "https://github.com/yzskyt/Vuln/blob/main/Go-RT-AC750/Go-RT-AC750.md"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-26822",
"datePublished": "2023-04-01T00:00:00.000Z",
"dateReserved": "2023-02-27T00:00:00.000Z",
"dateUpdated": "2025-02-11T17:12:28.548Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-37055 (GCVE-0-2022-37055)
Vulnerability from cvelistv5 – Published: 2022-08-28 16:05 – Updated: 2025-12-09 04:55
VLAI?
Summary
D-Link Go-RT-AC750 GORTAC750_revA_v101b03 and GO-RT-AC750_revB_FWv200b02 are vulnerable to Buffer Overflow via cgibin, hnap_main,
Severity ?
9.8 (Critical)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T10:21:32.589Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.dlink.com/en/security-bulletin/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://drive.google.com/file/d/1hmIk0jQoex4QDyjIUg_6yxi-J6ROCh8S/view?usp=sharing"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-37055",
"options": [
{
"Exploitation": "active"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-12-08T00:00:00+00:00",
"version": "2.0.3"
},
"type": "ssvc"
}
},
{
"other": {
"content": {
"dateAdded": "2025-12-08",
"reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2022-37055"
},
"type": "kev"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-12-09T04:55:55.687Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://www.fortiguard.com/outbreak-alert/d-link-multiple-devices-attack"
},
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2022-37055"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-12-08T00:00:00+00:00",
"value": "CVE-2022-37055 added to CISA KEV"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "D-Link Go-RT-AC750 GORTAC750_revA_v101b03 and GO-RT-AC750_revB_FWv200b02 are vulnerable to Buffer Overflow via cgibin, hnap_main,"
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-06T14:51:10.345Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.dlink.com/en/security-bulletin/"
},
{
"url": "https://drive.google.com/file/d/1hmIk0jQoex4QDyjIUg_6yxi-J6ROCh8S/view?usp=sharing"
},
{
"url": "https://supportannouncement.us.dlink.com/security/publication.aspx?name=SAP10308"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2022-37055",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "D-Link Go-RT-AC750 GORTAC750_revA_v101b03 and GO-RT-AC750_revB_FWv200b02 are vulnerable to Buffer Overflow via cgibin, hnap_main,"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.dlink.com/en/security-bulletin/",
"refsource": "MISC",
"url": "https://www.dlink.com/en/security-bulletin/"
},
{
"name": "https://drive.google.com/file/d/1hmIk0jQoex4QDyjIUg_6yxi-J6ROCh8S/view?usp=sharing",
"refsource": "MISC",
"url": "https://drive.google.com/file/d/1hmIk0jQoex4QDyjIUg_6yxi-J6ROCh8S/view?usp=sharing"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2022-37055",
"datePublished": "2022-08-28T16:05:21.000Z",
"dateReserved": "2022-08-01T00:00:00.000Z",
"dateUpdated": "2025-12-09T04:55:55.687Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2022-37056 (GCVE-0-2022-37056)
Vulnerability from cvelistv5 – Published: 2022-08-28 16:03 – Updated: 2025-01-09 17:38
VLAI?
Summary
D-Link GO-RT-AC750 GORTAC750_revA_v101b03 and GO-RT-AC750_revB_FWv200b02 is vulnerable to Command Injection via /cgibin, hnap_main,
Severity ?
9.8 (Critical)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T10:21:32.734Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.dlink.com/en/security-bulletin/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://drive.google.com/file/d/127tqMUvAxQ4OlycoSNtcP0x2282Y75GJ/view?usp=sharing"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-37056",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-09T15:56:42.079801Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-09T17:38:08.414Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "D-Link GO-RT-AC750 GORTAC750_revA_v101b03 and GO-RT-AC750_revB_FWv200b02 is vulnerable to Command Injection via /cgibin, hnap_main,"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-06T14:32:07.758Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.dlink.com/en/security-bulletin/"
},
{
"url": "https://drive.google.com/file/d/127tqMUvAxQ4OlycoSNtcP0x2282Y75GJ/view?usp=sharing"
},
{
"url": "https://supportannouncement.us.dlink.com/security/publication.aspx?name=SAP10308"
}
],
"x_generator": {
"engine": "enrichogram 0.0.1"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2022-37056",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "D-Link GO-RT-AC750 GORTAC750_revA_v101b03 and GO-RT-AC750_revB_FWv200b02 is vulnerable to Command Injection via /cgibin, hnap_main,"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.dlink.com/en/security-bulletin/",
"refsource": "MISC",
"url": "https://www.dlink.com/en/security-bulletin/"
},
{
"name": "https://drive.google.com/file/d/127tqMUvAxQ4OlycoSNtcP0x2282Y75GJ/view?usp=sharing",
"refsource": "MISC",
"url": "https://drive.google.com/file/d/127tqMUvAxQ4OlycoSNtcP0x2282Y75GJ/view?usp=sharing"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2022-37056",
"datePublished": "2022-08-28T16:03:48",
"dateReserved": "2022-08-01T00:00:00",
"dateUpdated": "2025-01-09T17:38:08.414Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-27683 (GCVE-0-2024-27683)
Vulnerability from nvd – Published: 2024-03-21 00:00 – Updated: 2024-08-14 19:07
VLAI?
Summary
D-Link Go-RT-AC750 GORTAC750_A1_FW_v101b03 contains a stack-based buffer overflow via the function hnap_main. An attacker can send a POST request to trigger the vulnerablilify.
Severity ?
9.8 (Critical)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T00:34:52.538Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.dlink.com/en/security-bulletin/"
},
{
"tags": [
"x_transferred"
],
"url": "https://drive.google.com/file/d/18RhbBnaD_kH16Y6C-7TpSSPUmYKKyU_k/view"
},
{
"tags": [
"x_transferred"
],
"url": "https://gist.github.com/sunwithmoon/428c3871482a600382fec0a1994a518b"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:dlink:go-rt-ac750_firmware:101b03:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "go-rt-ac750_firmware",
"vendor": "dlink",
"versions": [
{
"status": "affected",
"version": "101b03"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-27683",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-14T19:03:53.243547Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-14T19:07:30.354Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "D-Link Go-RT-AC750 GORTAC750_A1_FW_v101b03 contains a stack-based buffer overflow via the function hnap_main. An attacker can send a POST request to trigger the vulnerablilify."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-21T11:32:39.559169",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.dlink.com/en/security-bulletin/"
},
{
"url": "https://drive.google.com/file/d/18RhbBnaD_kH16Y6C-7TpSSPUmYKKyU_k/view"
},
{
"url": "https://gist.github.com/sunwithmoon/428c3871482a600382fec0a1994a518b"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-27683",
"datePublished": "2024-03-21T00:00:00",
"dateReserved": "2024-02-26T00:00:00",
"dateUpdated": "2024-08-14T19:07:30.354Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-27684 (GCVE-0-2024-27684)
Vulnerability from nvd – Published: 2024-03-04 00:00 – Updated: 2024-08-16 15:53
VLAI?
Summary
A Cross-site scripting (XSS) vulnerability in dlapn.cgi, dldongle.cgi, dlcfg.cgi, fwup.cgi and seama.cgi in D-Link GORTAC750_A1_FW_v101b03 allows remote attackers to inject arbitrary web script or HTML via the url parameter.
Severity ?
6.1 (Medium)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T00:34:52.524Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.dlink.com/en/security-bulletin/"
},
{
"tags": [
"x_transferred"
],
"url": "https://drive.google.com/file/d/1qu4iBQGeAwolTXjVOTXsAAusSHo2ie-Y/view"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:dlink:gortac750_a1_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "gortac750_a1_firmware",
"vendor": "dlink",
"versions": [
{
"status": "affected",
"version": "101b03"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-27684",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-03-04T16:35:29.279350Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-16T15:53:22.513Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A Cross-site scripting (XSS) vulnerability in dlapn.cgi, dldongle.cgi, dlcfg.cgi, fwup.cgi and seama.cgi in D-Link GORTAC750_A1_FW_v101b03 allows remote attackers to inject arbitrary web script or HTML via the url parameter."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-04T13:47:37.638773",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.dlink.com/en/security-bulletin/"
},
{
"url": "https://drive.google.com/file/d/1qu4iBQGeAwolTXjVOTXsAAusSHo2ie-Y/view"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-27684",
"datePublished": "2024-03-04T00:00:00",
"dateReserved": "2024-02-26T00:00:00",
"dateUpdated": "2024-08-16T15:53:22.513Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-22852 (GCVE-0-2024-22852)
Vulnerability from nvd – Published: 2024-02-06 00:00 – Updated: 2025-05-15 19:45
VLAI?
Summary
D-Link Go-RT-AC750 GORTAC750_A1_FW_v101b03 contains a stack-based buffer overflow via the function genacgi_main. This vulnerability allows attackers to enable telnet service via a specially crafted payload.
Severity ?
9.8 (Critical)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T22:51:11.136Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.dlink.com/en/security-bulletin/"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/Beckaf/vunl/blob/main/D-Link/AC750/1/1.md"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-22852",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-08T15:58:45.552998Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787 Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-05-15T19:45:54.686Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "D-Link Go-RT-AC750 GORTAC750_A1_FW_v101b03 contains a stack-based buffer overflow via the function genacgi_main. This vulnerability allows attackers to enable telnet service via a specially crafted payload."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-02-06T01:18:42.565Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.dlink.com/en/security-bulletin/"
},
{
"url": "https://github.com/Beckaf/vunl/blob/main/D-Link/AC750/1/1.md"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-22852",
"datePublished": "2024-02-06T00:00:00.000Z",
"dateReserved": "2024-01-11T00:00:00.000Z",
"dateUpdated": "2025-05-15T19:45:54.686Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-22853 (GCVE-0-2024-22853)
Vulnerability from nvd – Published: 2024-02-06 00:00 – Updated: 2025-06-20 20:13
VLAI?
Summary
D-LINK Go-RT-AC750 GORTAC750_A1_FW_v101b03 has a hardcoded password for the Alphanetworks account, which allows remote attackers to obtain root access via a telnet session.
Severity ?
9.8 (Critical)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T22:51:11.111Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.dlink.com/en/security-bulletin/"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/Beckaf/vunl/blob/main/D-Link/AC750/2/2.md"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-22853",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-02-06T15:37:40.936496Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798 Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-20T20:13:39.786Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "D-LINK Go-RT-AC750 GORTAC750_A1_FW_v101b03 has a hardcoded password for the Alphanetworks account, which allows remote attackers to obtain root access via a telnet session."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-02-06T01:18:48.256Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.dlink.com/en/security-bulletin/"
},
{
"url": "https://github.com/Beckaf/vunl/blob/main/D-Link/AC750/2/2.md"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-22853",
"datePublished": "2024-02-06T00:00:00.000Z",
"dateReserved": "2024-01-11T00:00:00.000Z",
"dateUpdated": "2025-06-20T20:13:39.786Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-22916 (GCVE-0-2024-22916)
Vulnerability from nvd – Published: 2024-01-16 00:00 – Updated: 2024-08-29 19:53
VLAI?
Summary
In D-LINK Go-RT-AC750 v101b03, the sprintf function in the sub_40E700 function within the cgibin is susceptible to stack overflow.
Severity ?
9.8 (Critical)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T22:51:11.195Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.dlink.com/en/security-bulletin/"
},
{
"tags": [
"x_transferred"
],
"url": "https://kee02p.github.io/2024/01/13/CVE-2024-22916/"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:dlink:go-rt-ac750_firmware:101b03:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "go-rt-ac750_firmware",
"vendor": "dlink",
"versions": [
{
"status": "affected",
"version": "101b03"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-22916",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-29T19:45:54.326640Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787 Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-29T19:53:52.941Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "In D-LINK Go-RT-AC750 v101b03, the sprintf function in the sub_40E700 function within the cgibin is susceptible to stack overflow."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-01-16T22:07:20.612751",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.dlink.com/en/security-bulletin/"
},
{
"url": "https://kee02p.github.io/2024/01/13/CVE-2024-22916/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-22916",
"datePublished": "2024-01-16T00:00:00",
"dateReserved": "2024-01-11T00:00:00",
"dateUpdated": "2024-08-29T19:53:52.941Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-48842 (GCVE-0-2023-48842)
Vulnerability from nvd – Published: 2023-12-01 00:00 – Updated: 2025-06-03 02:24
VLAI?
Summary
D-Link Go-RT-AC750 revA_v101b03 was discovered to contain a command injection vulnerability via the service parameter at hedwig.cgi.
Severity ?
9.8 (Critical)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T21:46:28.238Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://drive.google.com/file/d/1y5om__f2SAhNmcPqDxC_SRTvJVAWwPcH/view?usp=drive_link"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2023-48842",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-03T02:23:28.359315Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-03T02:24:53.955Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "D-Link Go-RT-AC750 revA_v101b03 was discovered to contain a command injection vulnerability via the service parameter at hedwig.cgi."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-01T15:16:04.709Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://drive.google.com/file/d/1y5om__f2SAhNmcPqDxC_SRTvJVAWwPcH/view?usp=drive_link"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-48842",
"datePublished": "2023-12-01T00:00:00.000Z",
"dateReserved": "2023-11-20T00:00:00.000Z",
"dateUpdated": "2025-06-03T02:24:53.955Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-34800 (GCVE-0-2023-34800)
Vulnerability from nvd – Published: 2023-06-15 00:00 – Updated: 2024-12-16 19:45
VLAI?
Summary
D-Link Go-RT-AC750 revA_v101b03 was discovered to contain a command injection vulnerability via the service parameter at genacgi_main.
Severity ?
9.8 (Critical)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T16:17:04.339Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.dlink.com/en/security-bulletin/"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/Tyaoo/IoT-Vuls/blob/main/dlink/Go-RT-AC750/vul.md"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2023-34800",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-12-16T19:42:04.175887Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-12-16T19:45:16.331Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "D-Link Go-RT-AC750 revA_v101b03 was discovered to contain a command injection vulnerability via the service parameter at genacgi_main."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-06-15T00:00:00",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.dlink.com/en/security-bulletin/"
},
{
"url": "https://github.com/Tyaoo/IoT-Vuls/blob/main/dlink/Go-RT-AC750/vul.md"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-34800",
"datePublished": "2023-06-15T00:00:00",
"dateReserved": "2023-06-07T00:00:00",
"dateUpdated": "2024-12-16T19:45:16.331Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-26822 (GCVE-0-2023-26822)
Vulnerability from nvd – Published: 2023-04-01 00:00 – Updated: 2025-02-11 17:12
VLAI?
Summary
D-Link Go-RT-AC750 revA_v101b03 was discovered to contain a command injection vulnerability via the service parameter at soapcgi.main.
Severity ?
9.8 (Critical)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T11:53:54.522Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.dlink.com/en/security-bulletin/"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/yzskyt/Vuln/blob/main/Go-RT-AC750/Go-RT-AC750.md"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2023-26822",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-11T17:12:22.889168Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-11T17:12:28.548Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "D-Link Go-RT-AC750 revA_v101b03 was discovered to contain a command injection vulnerability via the service parameter at soapcgi.main."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-04-01T00:00:00.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.dlink.com/en/security-bulletin/"
},
{
"url": "https://github.com/yzskyt/Vuln/blob/main/Go-RT-AC750/Go-RT-AC750.md"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-26822",
"datePublished": "2023-04-01T00:00:00.000Z",
"dateReserved": "2023-02-27T00:00:00.000Z",
"dateUpdated": "2025-02-11T17:12:28.548Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-37055 (GCVE-0-2022-37055)
Vulnerability from nvd – Published: 2022-08-28 16:05 – Updated: 2025-12-09 04:55
VLAI?
Summary
D-Link Go-RT-AC750 GORTAC750_revA_v101b03 and GO-RT-AC750_revB_FWv200b02 are vulnerable to Buffer Overflow via cgibin, hnap_main,
Severity ?
9.8 (Critical)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T10:21:32.589Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.dlink.com/en/security-bulletin/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://drive.google.com/file/d/1hmIk0jQoex4QDyjIUg_6yxi-J6ROCh8S/view?usp=sharing"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-37055",
"options": [
{
"Exploitation": "active"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-12-08T00:00:00+00:00",
"version": "2.0.3"
},
"type": "ssvc"
}
},
{
"other": {
"content": {
"dateAdded": "2025-12-08",
"reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2022-37055"
},
"type": "kev"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-12-09T04:55:55.687Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://www.fortiguard.com/outbreak-alert/d-link-multiple-devices-attack"
},
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2022-37055"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-12-08T00:00:00+00:00",
"value": "CVE-2022-37055 added to CISA KEV"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "D-Link Go-RT-AC750 GORTAC750_revA_v101b03 and GO-RT-AC750_revB_FWv200b02 are vulnerable to Buffer Overflow via cgibin, hnap_main,"
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-06T14:51:10.345Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.dlink.com/en/security-bulletin/"
},
{
"url": "https://drive.google.com/file/d/1hmIk0jQoex4QDyjIUg_6yxi-J6ROCh8S/view?usp=sharing"
},
{
"url": "https://supportannouncement.us.dlink.com/security/publication.aspx?name=SAP10308"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2022-37055",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "D-Link Go-RT-AC750 GORTAC750_revA_v101b03 and GO-RT-AC750_revB_FWv200b02 are vulnerable to Buffer Overflow via cgibin, hnap_main,"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.dlink.com/en/security-bulletin/",
"refsource": "MISC",
"url": "https://www.dlink.com/en/security-bulletin/"
},
{
"name": "https://drive.google.com/file/d/1hmIk0jQoex4QDyjIUg_6yxi-J6ROCh8S/view?usp=sharing",
"refsource": "MISC",
"url": "https://drive.google.com/file/d/1hmIk0jQoex4QDyjIUg_6yxi-J6ROCh8S/view?usp=sharing"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2022-37055",
"datePublished": "2022-08-28T16:05:21.000Z",
"dateReserved": "2022-08-01T00:00:00.000Z",
"dateUpdated": "2025-12-09T04:55:55.687Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}