3 vulnerabilities found for gv-gf192x_firmware by geovision
FKIE_CVE-2020-3930
Vulnerability from fkie_nvd - Published: 2020-06-12 09:15 - Updated: 2024-11-21 05:31
Severity ?
4.0 (Medium) - CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
3.3 (Low) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N
3.3 (Low) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N
Summary
GeoVision Door Access Control device family improperly stores and controls access to system logs, any users can read these logs.
References
| URL | Tags | ||
|---|---|---|---|
| twcert@cert.org.tw | https://www.twcert.org.tw/tw/cp-132-3697-780d0-1.html | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.twcert.org.tw/tw/cp-132-3697-780d0-1.html | Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| geovision | gv-gf192x_firmware | 1.10 | |
| geovision | gv-gf192x | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:geovision:gv-gf192x_firmware:1.10:*:*:*:*:*:*:*",
"matchCriteriaId": "B7D364DC-35A5-48F0-A937-F65CC3A94B69",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:geovision:gv-gf192x:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D961B456-5537-404D-9335-BAAAD17BDC45",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "GeoVision Door Access Control device family improperly stores and controls access to system logs, any users can read these logs."
},
{
"lang": "es",
"value": "La familia de dispositivos GeoVision Door Access Control almacena y controla inapropiadamente el acceso a los registros del sistema, cualquier usuario puede leer estos registros"
}
],
"id": "CVE-2020-3930",
"lastModified": "2024-11-21T05:31:58.870",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "LOW",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 2.1,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 3.9,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 4.0,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.5,
"impactScore": 1.4,
"source": "twcert@cert.org.tw",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 3.3,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 1.4,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-06-12T09:15:10.460",
"references": [
{
"source": "twcert@cert.org.tw",
"tags": [
"Third Party Advisory"
],
"url": "https://www.twcert.org.tw/tw/cp-132-3697-780d0-1.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://www.twcert.org.tw/tw/cp-132-3697-780d0-1.html"
}
],
"sourceIdentifier": "twcert@cert.org.tw",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-532"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
CVE-2020-3930 (GCVE-0-2020-3930)
Vulnerability from cvelistv5 – Published: 2020-06-12 08:25 – Updated: 2024-09-16 16:57
VLAI?
Title
GeoVision Door Access Control Device - Information disclosure vulnerability
Summary
GeoVision Door Access Control device family improperly stores and controls access to system logs, any users can read these logs.
Severity ?
4 (Medium)
CWE
- Information disclosure vulnerability
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| GeoVision | Door Access Control Device |
Affected:
GV-GF192x , ≤ 1.10
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T07:52:20.429Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.twcert.org.tw/tw/cp-132-3697-780d0-1.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Door Access Control Device",
"vendor": "GeoVision",
"versions": [
{
"lessThanOrEqual": "1.10",
"status": "affected",
"version": "GV-GF192x",
"versionType": "custom"
}
]
}
],
"datePublic": "2020-06-12T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "GeoVision Door Access Control device family improperly stores and controls access to system logs, any users can read these logs."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Information disclosure vulnerability",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-06-12T08:25:23",
"orgId": "cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e",
"shortName": "twcert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.twcert.org.tw/tw/cp-132-3697-780d0-1.html"
}
],
"solutions": [
{
"lang": "en",
"value": "Update to version 1.22 in GV-GF192x"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "GeoVision Door Access Control Device - Information disclosure vulnerability",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"AKA": "TWCERT/CC",
"ASSIGNER": "cve@cert.org.tw",
"DATE_PUBLIC": "2020-06-12T08:00:00.000Z",
"ID": "CVE-2020-3930",
"STATE": "PUBLIC",
"TITLE": "GeoVision Door Access Control Device - Information disclosure vulnerability"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Door Access Control Device",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "GV-GF192x",
"version_value": "1.10"
}
]
}
}
]
},
"vendor_name": "GeoVision"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "GeoVision Door Access Control device family improperly stores and controls access to system logs, any users can read these logs."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Information disclosure vulnerability"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.twcert.org.tw/tw/cp-132-3697-780d0-1.html",
"refsource": "MISC",
"url": "https://www.twcert.org.tw/tw/cp-132-3697-780d0-1.html"
}
]
},
"solution": [
{
"lang": "en",
"value": "Update to version 1.22 in GV-GF192x"
}
],
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e",
"assignerShortName": "twcert",
"cveId": "CVE-2020-3930",
"datePublished": "2020-06-12T08:25:23.937925Z",
"dateReserved": "2019-12-20T00:00:00",
"dateUpdated": "2024-09-16T16:57:40.077Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-3930 (GCVE-0-2020-3930)
Vulnerability from nvd – Published: 2020-06-12 08:25 – Updated: 2024-09-16 16:57
VLAI?
Title
GeoVision Door Access Control Device - Information disclosure vulnerability
Summary
GeoVision Door Access Control device family improperly stores and controls access to system logs, any users can read these logs.
Severity ?
4 (Medium)
CWE
- Information disclosure vulnerability
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| GeoVision | Door Access Control Device |
Affected:
GV-GF192x , ≤ 1.10
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T07:52:20.429Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.twcert.org.tw/tw/cp-132-3697-780d0-1.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Door Access Control Device",
"vendor": "GeoVision",
"versions": [
{
"lessThanOrEqual": "1.10",
"status": "affected",
"version": "GV-GF192x",
"versionType": "custom"
}
]
}
],
"datePublic": "2020-06-12T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "GeoVision Door Access Control device family improperly stores and controls access to system logs, any users can read these logs."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Information disclosure vulnerability",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-06-12T08:25:23",
"orgId": "cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e",
"shortName": "twcert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.twcert.org.tw/tw/cp-132-3697-780d0-1.html"
}
],
"solutions": [
{
"lang": "en",
"value": "Update to version 1.22 in GV-GF192x"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "GeoVision Door Access Control Device - Information disclosure vulnerability",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"AKA": "TWCERT/CC",
"ASSIGNER": "cve@cert.org.tw",
"DATE_PUBLIC": "2020-06-12T08:00:00.000Z",
"ID": "CVE-2020-3930",
"STATE": "PUBLIC",
"TITLE": "GeoVision Door Access Control Device - Information disclosure vulnerability"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Door Access Control Device",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "GV-GF192x",
"version_value": "1.10"
}
]
}
}
]
},
"vendor_name": "GeoVision"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "GeoVision Door Access Control device family improperly stores and controls access to system logs, any users can read these logs."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Information disclosure vulnerability"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.twcert.org.tw/tw/cp-132-3697-780d0-1.html",
"refsource": "MISC",
"url": "https://www.twcert.org.tw/tw/cp-132-3697-780d0-1.html"
}
]
},
"solution": [
{
"lang": "en",
"value": "Update to version 1.22 in GV-GF192x"
}
],
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e",
"assignerShortName": "twcert",
"cveId": "CVE-2020-3930",
"datePublished": "2020-06-12T08:25:23.937925Z",
"dateReserved": "2019-12-20T00:00:00",
"dateUpdated": "2024-09-16T16:57:40.077Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}