All the vulnerabilites related to mitsubishielectric - gx_works3
cve-2020-14521
Vulnerability from cvelistv5
Published
2022-02-11 17:40
Modified
2024-09-16 23:45
Summary
Multiple Mitsubishi Electric Factory Automation engineering software products have a malicious code execution vulnerability. A malicious attacker could use this vulnerability to obtain information, modify information, and cause a denial-of-service condition.
Impacted products
Vendor Product Version
Mitsubishi Electric CC-Link IE Control Network Data Collector Version: Version 1.00A
Mitsubishi Electric CC-Link IE Field Network Data Collector Version: Version 1.00A
Mitsubishi Electric CC-Link IE TSN Data Collector Version: Version 1.00A
Mitsubishi Electric CPU Module Logging Configuration Tool Version: unspecified   <
Mitsubishi Electric CW Configurator Version: unspecified   <
Mitsubishi Electric Data Transfer Version: unspecified   <
Mitsubishi Electric EZSocket Version: unspecified   <
Mitsubishi Electric FR Configurator SW3 Version: All Versions
Mitsubishi Electric FR Configurator2 Version: unspecified   <
Mitsubishi Electric GT Designer2 Classic Version: All Versions
Mitsubishi Electric GT Designer3 Version1 (GOT1000) Version: unspecified   <
Mitsubishi Electric GT Designer3 Version1 (GOT2000) Version: unspecified   <
Mitsubishi Electric GT SoftGOT1000 Version3 Version: unspecified   <
Mitsubishi Electric GT SoftGOT2000 Version1 Version: unspecified   <
Mitsubishi Electric GX Developer Version: unspecified   <
Mitsubishi Electric GX LogViewer Version: unspecified   <
Mitsubishi Electric GX Works2 Version: unspecified   <
Mitsubishi Electric GX Works3 Version: unspecified   <
Mitsubishi Electric M_CommDTM-IO-Link Version: unspecified   <
Mitsubishi Electric MELFA-Works Version: unspecified   <
Mitsubishi Electric MELSEC WinCPU Setting Utility Version: All Versions
Mitsubishi Electric MELSOFT Complete Clean Up Tool Version: unspecified   <
Mitsubishi Electric MELSOFT EM Software Development Kit Version: unspecified   <
Mitsubishi Electric MELSOFT iQ AppPortal Version: unspecified   <
Mitsubishi Electric MELSOFT Navigator Version: unspecified   <
Mitsubishi Electric MI Configurator Version: unspecified   <
Mitsubishi Electric Motion Control Setting Version: unspecified   <
Mitsubishi Electric Motorizer Version: unspecified   <
Mitsubishi Electric MR Configurator2 Version: unspecified   <
Mitsubishi Electric MT Works2 Version: unspecified   <
Mitsubishi Electric MTConnect Data Collector Version: unspecified   <
Mitsubishi Electric MX Component Version: unspecified   <
Mitsubishi Electric MX MESInterface Version: unspecified   <
Mitsubishi Electric MX MESInterface-R Version: unspecified   <
Mitsubishi Electric MX Sheet Version: unspecified   <
Mitsubishi Electric Network Interface Board CC IE Control Utility Version: unspecified   <
Mitsubishi Electric Network Interface Board CC IE Field Utility Version: unspecified   <
Mitsubishi Electric Network Interface Board CC-Link Ver.2 Utility Version: unspecified   <
Mitsubishi Electric Network Interface Board MNETH Utility Version: unspecified   <
Mitsubishi Electric Position Board utility 2 Version: unspecified   <
Mitsubishi Electric PX Developer Version: unspecified   <
Mitsubishi Electric RT ToolBox2 Version: unspecified   <
Mitsubishi Electric RT ToolBox3 Version: unspecified   <
Mitsubishi Electric Setting/Monitoring tools for the C Controller module Version: unspecified   <
Version: unspecified   <
Mitsubishi Electric SLMP Data Collector Version: unspecified   <
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T12:46:34.835Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-04"
          },
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-007_en.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "C Controller Interface Module Utility",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Version 2.00",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CC-Link IE Control Network Data Collector",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Version 1.00A"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CC-Link IE Field Network Data Collector",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Version 1.00A"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CC-Link IE TSN Data Collector",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Version 1.00A"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CPU Module Logging Configuration Tool",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Version 1.100E",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CW Configurator",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Version 1.010L",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Data Transfer",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Version 3.42U",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EZSocket",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Version 5.1",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "FR Configurator SW3",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "FR Configurator2",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Version 1.26C",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GT Designer2 Classic",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GT Designer3 Version1 (GOT1000)",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Version 1.241B",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GT Designer3 Version1 (GOT2000)",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Version 1.241B",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GT SoftGOT1000 Version3",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Version 3.200J",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GT SoftGOT2000 Version1",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Version 1.241B",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GX Developer",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Version 8.504A",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GX LogViewer",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Version 1.100E",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GX Works2",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Version 1.601B",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GX Works3",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Version 1.063R",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "M_CommDTM-IO-Link",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Version 1.03D",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELFA-Works",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Version 4.4",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC WinCPU Setting Utility",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSOFT Complete Clean Up Tool",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Version 1.06G",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSOFT EM Software Development Kit",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Version 1.015R",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSOFT iQ AppPortal",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Version 1.17T",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSOFT Navigator",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Version 2.74C",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MI Configurator",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Version 1.004E",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Motion Control Setting",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Version 1.005F",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Motorizer",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Version 1.005F",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MR Configurator2",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Version 1.125F",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MT Works2",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Version 1.167Z",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MTConnect Data Collector",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Version 1.1.4.0",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MX Component",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Version 4.20W",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MX MESInterface",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Version 1.21X",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MX MESInterface-R",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Version 1.12N",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MX Sheet",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Version 2.15R",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Network Interface Board CC IE Control Utility",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Version 1.29F",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Network Interface Board CC IE Field Utility",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Versions 1.16S",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Network Interface Board CC-Link Ver.2 Utility",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Version 1.23Z",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Network Interface Board MNETH Utility",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Version 34L",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Position Board utility 2",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Version 3.20",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "PX Developer",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Version 1.53F",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "RT ToolBox2",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Version 3.73B",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "RT ToolBox3",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Version 1.82L",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Setting/Monitoring tools for the C Controller module",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "SW3PVC-CCPU Version 3.13P",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "SW4PVC-CCPU Version 4.12N",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "SLMP Data Collector",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Version 1.04E",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Mashav Sapir of Claroty reported this vulnerability to CISA"
        }
      ],
      "datePublic": "2020-07-30T06:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Multiple Mitsubishi Electric Factory Automation engineering software products have a malicious code execution vulnerability. A malicious attacker could use this vulnerability to obtain information, modify information, and cause a denial-of-service condition.\n\n\u003cp\u003e\u003c/p\u003e"
            }
          ],
          "value": "Multiple Mitsubishi Electric Factory Automation engineering software products have a malicious code execution vulnerability. A malicious attacker could use this vulnerability to obtain information, modify information, and cause a denial-of-service condition."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-428",
              "description": "CWE-428 Unquoted Search Path or Element",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-03-07T21:29:25.280Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-04"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-007_en.pdf"
        }
      ],
      "source": {
        "advisory": "ICSA-20-212-04",
        "discovery": "UNKNOWN"
      },
      "title": "Mitsubishi Electric Factory Automation Engineering Products Unquoted Search Path or Element",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2020-07-30T16:50:00.000Z",
          "ID": "CVE-2020-14521",
          "STATE": "PUBLIC",
          "TITLE": "Mitsubishi Electric Factory Automation Engineering Products Unquoted Search Path or Element"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "C Controller Interface Module Utility",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "All Versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "C Controller Module Setting and Monitoring Tool",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "All Versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CC-Link IE Control Network Data Collector",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "Version 1.00A"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CC-Link IE Field Network Data Collector",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "Version 1.00A"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CC-Link IE TSN Data Collector",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "Version 1.00A"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CPU Module Logging Configuration Tool",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "Version 1.100E"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CW Configurator",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "Version 1.010L"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Data Transfer",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "Version 3.42U and prior"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "EZSocket",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "Version 5.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "FR Configurator SW3",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "All Versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "FR Configurator2",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "All Versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "GT Designer2 Classic",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "All Versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "GT Designer3 Version1 (GOT1000)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "Version 1.241B"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "GT Designer3 Version1 (GOT2000)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "Version 1.241B"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "GT SoftGOT1000 Version3",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "Version 3.200J"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "GT SoftGOT2000 Version1",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "Version 1.241B"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "GX Developer",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "Version 8.504A"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "GX LogViewer",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "Version 1.100E"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "GX Works2",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "Version 1.601B"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "GX Works3",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "Version 1.063R"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "M_CommDTM-IO-Link",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "All Versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "MELFA-Works",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "Version 4.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "MELSEC WinCPU Setting Utility",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "All Versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "MELSOFT Complete Clean Up Tool",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "Version 1.06G"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "MELSOFT EM Software Development Kit",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "All Versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "MELSOFT iQ AppPortal",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "Version 1.17T"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "MELSOFT Navigator",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "Version 2.74C"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "MI Configurator",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "All Versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Motion Control Setting",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "Version 1.005F"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Motorizer",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "Version 1.005F"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "MR Configurator2",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "Version 1.125F"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "MT Works2",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "Version 1.167Z"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "MTConnect Data Collector",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "Version 1.1.4.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "MX Component",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "Version 4.20W"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "MX MESInterface",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "Version 1.21X"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "MX MESInterface-R",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "Version 1.12N"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "MX Sheet",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "Version 2.15R"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Network Interface Board CC IE Control Utility",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "All Versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Network Interface Board CC IE Field Utility",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "All Versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Network Interface Board CC-Link Ver.2 Utility",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "All Versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Network Interface Board MNETH Utility",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "All Versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Position Board utility 2",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "All Versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "PX Developer",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "version 1.53F"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "RT ToolBox2",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "Version 3.73B"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "RT ToolBox3",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "Version 1.82L"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Setting/monitoring tools for the C Controller module",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "All Versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SLMP Data Collector",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "Version 1.04E"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Mitsubishi Electric"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Mashav Sapir of Claroty reported this vulnerability to CISA"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Multiple Mitsubishi Electric Factory Automation engineering software products have a malicious code execution vulnerability. A malicious attacker could use this vulnerability to obtain information, modify information, and cause a denial-of-service condition."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-428 Unquoted Search Path or Element"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-04",
              "refsource": "MISC",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-04"
            },
            {
              "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-007_en.pdf",
              "refsource": "MISC",
              "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-007_en.pdf"
            }
          ]
        },
        "solution": [
          {
            "lang": "en"
          }
        ],
        "source": {
          "advisory": "ICSA-20-212-04",
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2020-14521",
    "datePublished": "2022-02-11T17:40:28.403703Z",
    "dateReserved": "2020-06-19T00:00:00",
    "dateUpdated": "2024-09-16T23:45:38.115Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-29825
Vulnerability from cvelistv5
Published
2022-11-24 23:21
Modified
2024-08-03 06:33
Summary
Use of Hard-coded Password vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.090U and GT Designer3 Version1 (GOT2000) versions from 1.122C to 1.290C allows an unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users may view programs and project files or execute programs illegally.
Impacted products
Vendor Product Version
Mitsubishi Electric Corporation GT Designer3 Version1 (GOT2000) Version: from 1.122C to 1.290C
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T06:33:42.627Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
          },
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://jvn.jp/vu/JVNVU97244961/index.html"
          },
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "GX Works3",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "from 1.000A to 1.090U"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GT Designer3 Version1 (GOT2000)",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "from 1.122C to 1.290C"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Use of Hard-coded Password vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.090U and GT Designer3 Version1 (GOT2000) versions from 1.122C to 1.290C allows an unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users may view programs and project files or execute programs illegally."
            }
          ],
          "value": "Use of Hard-coded Password vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.090U and GT Designer3 Version1 (GOT2000) versions from 1.122C to 1.290C allows an unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users may view programs and project files or execute programs illegally."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 5.6,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-259",
              "description": "CWE-259 Use of Hard-coded Password",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-31T08:39:05.292Z",
        "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "shortName": "Mitsubishi"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://jvn.jp/vu/JVNVU97244961/index.html"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
    "assignerShortName": "Mitsubishi",
    "cveId": "CVE-2022-29825",
    "datePublished": "2022-11-24T23:21:54.776Z",
    "dateReserved": "2022-04-27T20:47:43.441Z",
    "dateUpdated": "2024-08-03T06:33:42.627Z",
    "requesterUserId": "520cc88b-a1c8-44f6-9154-21a4d74c769f",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2020-5603
Vulnerability from cvelistv5
Published
2020-06-30 10:20
Modified
2024-08-04 08:30
Severity ?
Summary
Uncontrolled resource consumption vulnerability in Mitsubishi Electoric FA Engineering Software (CPU Module Logging Configuration Tool Ver. 1.94Y and earlier, CW Configurator Ver. 1.010L and earlier, EM Software Development Kit (EM Configurator) Ver. 1.010L and earlier, GT Designer3 (GOT2000) Ver. 1.221F and earlier, GX LogViewer Ver. 1.96A and earlier, GX Works2 Ver. 1.586L and earlier, GX Works3 Ver. 1.058L and earlier, M_CommDTM-HART Ver. 1.00A, M_CommDTM-IO-Link Ver. 1.02C and earlier, MELFA-Works Ver. 4.3 and earlier, MELSEC-L Flexible High-Speed I/O Control Module Configuration Tool Ver.1.004E and earlier, MELSOFT FieldDeviceConfigurator Ver. 1.03D and earlier, MELSOFT iQ AppPortal Ver. 1.11M and earlier, MELSOFT Navigator Ver. 2.58L and earlier, MI Configurator Ver. 1.003D and earlier, Motion Control Setting Ver. 1.005F and earlier, MR Configurator2 Ver. 1.72A and earlier, MT Works2 Ver. 1.156N and earlier, RT ToolBox2 Ver. 3.72A and earlier, and RT ToolBox3 Ver. 1.50C and earlier) allows an attacker to cause a denial of service (DoS) condition attacks via unspecified vectors.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T08:30:24.586Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-004_en.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://jvn.jp/en/vu/JVNVU90307594/index.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Mitsubishi Electoric FA Engineering Software",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "CPU Module Logging Configuration Tool Ver. 1.94Y and earlier, CW Configurator Ver. 1.010L and earlier, EM Software Development Kit (EM Configurator) Ver. 1.010L and earlier, GT Designer3 (GOT2000) Ver. 1.221F and earlier, GX LogViewer Ver. 1.96A and earlier, GX Works2 Ver. 1.586L and earlier, GX Works3 Ver. 1.058L and earlier, M_CommDTM-HART Ver. 1.00A, M_CommDTM-IO-Link Ver. 1.02C and earlier, MELFA-Works Ver. 4.3 and earlier, MELSEC-L Flexible High-Speed I/O Control Module Configuration Tool Ver.1.004E and earlier, MELSOFT FieldDeviceConfigurator Ver. 1.03D and earlier, MELSOFT iQ AppPortal Ver. 1.11M and earlier, MELSOFT Navigator Ver. 2.58L and earlier, MI Configurator Ver. 1.003D and earlier, Motion Control Setting Ver. 1.005F and earlier, MR Configurator2 Ver. 1.72A and earlier, MT Works2 Ver. 1.156N and earlier, RT ToolBox2 Ver. 3.72A and earlier, and RT ToolBox3 Ver. 1.50C and earlier"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Uncontrolled resource consumption vulnerability in Mitsubishi Electoric FA Engineering Software (CPU Module Logging Configuration Tool Ver. 1.94Y and earlier, CW Configurator Ver. 1.010L and earlier, EM Software Development Kit (EM Configurator) Ver. 1.010L and earlier, GT Designer3 (GOT2000) Ver. 1.221F and earlier, GX LogViewer Ver. 1.96A and earlier, GX Works2 Ver. 1.586L and earlier, GX Works3 Ver. 1.058L and earlier, M_CommDTM-HART Ver. 1.00A, M_CommDTM-IO-Link Ver. 1.02C and earlier, MELFA-Works Ver. 4.3 and earlier, MELSEC-L Flexible High-Speed I/O Control Module Configuration Tool Ver.1.004E and earlier, MELSOFT FieldDeviceConfigurator Ver. 1.03D and earlier, MELSOFT iQ AppPortal Ver. 1.11M and earlier, MELSOFT Navigator Ver. 2.58L and earlier, MI Configurator Ver. 1.003D and earlier, Motion Control Setting Ver. 1.005F and earlier, MR Configurator2 Ver. 1.72A and earlier, MT Works2 Ver. 1.156N and earlier, RT ToolBox2 Ver. 3.72A and earlier, and RT ToolBox3 Ver. 1.50C and earlier) allows an attacker to cause a denial of service (DoS) condition attacks via unspecified vectors."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Uncontrolled Resource Consumption",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-06-30T10:20:45",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-004_en.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://jvn.jp/en/vu/JVNVU90307594/index.html"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "vultures@jpcert.or.jp",
          "ID": "CVE-2020-5603",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Mitsubishi Electoric FA Engineering Software",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "CPU Module Logging Configuration Tool Ver. 1.94Y and earlier, CW Configurator Ver. 1.010L and earlier, EM Software Development Kit (EM Configurator) Ver. 1.010L and earlier, GT Designer3 (GOT2000) Ver. 1.221F and earlier, GX LogViewer Ver. 1.96A and earlier, GX Works2 Ver. 1.586L and earlier, GX Works3 Ver. 1.058L and earlier, M_CommDTM-HART Ver. 1.00A, M_CommDTM-IO-Link Ver. 1.02C and earlier, MELFA-Works Ver. 4.3 and earlier, MELSEC-L Flexible High-Speed I/O Control Module Configuration Tool Ver.1.004E and earlier, MELSOFT FieldDeviceConfigurator Ver. 1.03D and earlier, MELSOFT iQ AppPortal Ver. 1.11M and earlier, MELSOFT Navigator Ver. 2.58L and earlier, MI Configurator Ver. 1.003D and earlier, Motion Control Setting Ver. 1.005F and earlier, MR Configurator2 Ver. 1.72A and earlier, MT Works2 Ver. 1.156N and earlier, RT ToolBox2 Ver. 3.72A and earlier, and RT ToolBox3 Ver. 1.50C and earlier"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Mitsubishi Electric Corporation"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Uncontrolled resource consumption vulnerability in Mitsubishi Electoric FA Engineering Software (CPU Module Logging Configuration Tool Ver. 1.94Y and earlier, CW Configurator Ver. 1.010L and earlier, EM Software Development Kit (EM Configurator) Ver. 1.010L and earlier, GT Designer3 (GOT2000) Ver. 1.221F and earlier, GX LogViewer Ver. 1.96A and earlier, GX Works2 Ver. 1.586L and earlier, GX Works3 Ver. 1.058L and earlier, M_CommDTM-HART Ver. 1.00A, M_CommDTM-IO-Link Ver. 1.02C and earlier, MELFA-Works Ver. 4.3 and earlier, MELSEC-L Flexible High-Speed I/O Control Module Configuration Tool Ver.1.004E and earlier, MELSOFT FieldDeviceConfigurator Ver. 1.03D and earlier, MELSOFT iQ AppPortal Ver. 1.11M and earlier, MELSOFT Navigator Ver. 2.58L and earlier, MI Configurator Ver. 1.003D and earlier, Motion Control Setting Ver. 1.005F and earlier, MR Configurator2 Ver. 1.72A and earlier, MT Works2 Ver. 1.156N and earlier, RT ToolBox2 Ver. 3.72A and earlier, and RT ToolBox3 Ver. 1.50C and earlier) allows an attacker to cause a denial of service (DoS) condition attacks via unspecified vectors."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Uncontrolled Resource Consumption"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-004_en.pdf",
              "refsource": "MISC",
              "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-004_en.pdf"
            },
            {
              "name": "https://jvn.jp/en/vu/JVNVU90307594/index.html",
              "refsource": "MISC",
              "url": "https://jvn.jp/en/vu/JVNVU90307594/index.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2020-5603",
    "datePublished": "2020-06-30T10:20:45",
    "dateReserved": "2020-01-06T00:00:00",
    "dateUpdated": "2024-08-04T08:30:24.586Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-29831
Vulnerability from cvelistv5
Published
2022-11-24 23:36
Modified
2024-08-03 06:33
Summary
Use of Hard-coded Password vulnerability in Mitsubishi Electric Corporation GX Works3 versions from 1.015R to 1.095Z allows a remote unauthenticated attacker to obtain information about the project file for MELSEC safety CPU modules.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T06:33:42.702Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
          },
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://jvn.jp/vu/JVNVU97244961"
          },
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "GX Works3",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "from 1.015R to 1.095Z"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Use of Hard-coded Password vulnerability in Mitsubishi Electric Corporation GX Works3 versions from 1.015R to 1.095Z allows a remote unauthenticated attacker to obtain information about the project file for MELSEC safety CPU modules."
            }
          ],
          "value": "Use of Hard-coded Password vulnerability in Mitsubishi Electric Corporation GX Works3 versions from 1.015R to 1.095Z allows a remote unauthenticated attacker to obtain information about the project file for MELSEC safety CPU modules."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-259",
              "description": "CWE-259 Use of Hard-coded Password",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-06-29T04:02:40.073Z",
        "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "shortName": "Mitsubishi"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://jvn.jp/vu/JVNVU97244961"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
    "assignerShortName": "Mitsubishi",
    "cveId": "CVE-2022-29831",
    "datePublished": "2022-11-24T23:36:18.688Z",
    "dateReserved": "2022-04-27T20:47:43.444Z",
    "dateUpdated": "2024-08-03T06:33:42.702Z",
    "requesterUserId": "520cc88b-a1c8-44f6-9154-21a4d74c769f",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-25164
Vulnerability from cvelistv5
Published
2022-11-24 23:21
Modified
2024-08-03 04:36
Summary
Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Mitsubishi Electric MX OPC UA Module Configurator-R versions 1.08J and prior allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers can gain unauthorized access to the MELSEC CPU module and the MELSEC OPC UA server module.
Impacted products
Vendor Product Version
Mitsubishi Electric Corporation MX OPC UA Module Configurator-R Version: 1.08J and prior
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:36:05.086Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
          },
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://jvn.jp/vu/JVNVU97244961/index.html"
          },
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "GX Works3",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "from 1.000A to 1.095Z"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MX OPC UA Module Configurator-R",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "1.08J and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Mitsubishi Electric MX OPC UA Module Configurator-R versions 1.08J and prior allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers can gain unauthorized access to the MELSEC CPU module and the MELSEC OPC UA server module."
            }
          ],
          "value": "Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Mitsubishi Electric MX OPC UA Module Configurator-R versions 1.08J and prior allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers can gain unauthorized access to the MELSEC CPU module and the MELSEC OPC UA server module."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 8.6,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "CWE-312 Cleartext Storage of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-06-29T07:41:03.163Z",
        "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "shortName": "Mitsubishi"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://jvn.jp/vu/JVNVU97244961/index.html"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
    "assignerShortName": "Mitsubishi",
    "cveId": "CVE-2022-25164",
    "datePublished": "2022-11-24T23:21:25.536Z",
    "dateReserved": "2022-02-14T22:38:29.671Z",
    "dateUpdated": "2024-08-03T04:36:05.086Z",
    "requesterUserId": "520cc88b-a1c8-44f6-9154-21a4d74c769f",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-29833
Vulnerability from cvelistv5
Published
2022-11-24 23:38
Modified
2024-08-03 06:33
Summary
Insufficiently Protected Credentials vulnerability in Mitsubishi Electric Corporation GX Works3 versions 1.015R and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users could access to MELSEC safety CPU modules illgally.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T06:33:42.773Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
          },
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://jvn.jp/vu/JVNVU97244961"
          },
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "GX Works3",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "1.015R and later"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Insufficiently Protected Credentials vulnerability in Mitsubishi Electric Corporation GX Works3 versions 1.015R and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users could access to MELSEC safety CPU modules illgally."
            }
          ],
          "value": "Insufficiently Protected Credentials vulnerability in Mitsubishi Electric Corporation GX Works3 versions 1.015R and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users could access to MELSEC safety CPU modules illgally."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:N/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-522",
              "description": "CWE-522 Insufficiently Protected Credentials",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-31T06:41:53.985Z",
        "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "shortName": "Mitsubishi"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://jvn.jp/vu/JVNVU97244961"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
    "assignerShortName": "Mitsubishi",
    "cveId": "CVE-2022-29833",
    "datePublished": "2022-11-24T23:38:06.033Z",
    "dateReserved": "2022-04-27T20:47:43.445Z",
    "dateUpdated": "2024-08-03T06:33:42.773Z",
    "requesterUserId": "520cc88b-a1c8-44f6-9154-21a4d74c769f",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-6942
Vulnerability from cvelistv5
Published
2024-01-30 09:06
Modified
2024-11-01 08:35
Summary
Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 and later, GT Designer3 Version1(GOT1000) all versions, GT Designer3 Version1(GOT2000) all versions, GX Works2 versions 1.11M and later, GX Works3 versions 1.106L and prior, MELSOFT Navigator versions 1.04E and later, MT Works2 all versions, MX Component versions 4.00A and later and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to bypass authentication by sending specially crafted packets and connect to the products illegally.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T08:42:08.534Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-020_en.pdf"
          },
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://jvn.jp/vu/JVNVU95103362"
          },
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-030-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "EZSocket",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "3.0 and later"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GT Designer3 Version1(GOT1000)",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GT Designer3 Version1(GOT2000)",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GX Works2",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "1.11M and later"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GX Works3",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "1.106L and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSOFT Navigator",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "1.04E and later"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MT Works2",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MX Component",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "4.00A and later"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MX OPC Server DA/UA",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 and later, GT Designer3 Version1(GOT1000) all versions, GT Designer3 Version1(GOT2000) all versions, GX Works2 versions 1.11M and later, GX Works3 versions 1.106L and prior, MELSOFT Navigator versions 1.04E and later, MT Works2 all versions, MX Component versions 4.00A and later and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to bypass authentication by sending specially crafted packets and connect to the products illegally."
            }
          ],
          "value": "Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 and later, GT Designer3 Version1(GOT1000) all versions, GT Designer3 Version1(GOT2000) all versions, GX Works2 versions 1.11M and later, GX Works3 versions 1.106L and prior, MELSOFT Navigator versions 1.04E and later, MT Works2 all versions, MX Component versions 4.00A and later and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to bypass authentication by sending specially crafted packets and connect to the products illegally."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-115",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-115 Authentication Bypass"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306 Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-01T08:35:48.579Z",
        "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "shortName": "Mitsubishi"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-020_en.pdf"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://jvn.jp/vu/JVNVU95103362"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-030-02"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
    "assignerShortName": "Mitsubishi",
    "cveId": "CVE-2023-6942",
    "datePublished": "2024-01-30T09:06:27.941Z",
    "dateReserved": "2023-12-19T08:00:02.751Z",
    "dateUpdated": "2024-11-01T08:35:48.579Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-25086
Vulnerability from cvelistv5
Published
2024-07-02 00:00
Modified
2024-08-01 23:36
Summary
Improper privilege management in Jungo WinDriver before 12.2.0 allows local attackers to escalate privileges and execute arbitrary code.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:jungo:windriver:12.2.0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "windriver",
            "vendor": "jungo",
            "versions": [
              {
                "lessThan": "12.2.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-25086",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-03T14:39:42.792039Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-94",
                "description": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          },
          {
            "descriptions": [
              {
                "cweId": "CWE-269",
                "description": "CWE-269 Improper Privilege Management",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-03T14:45:40.596Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T23:36:21.814Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://jungo.com/windriver/versions/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-001_en.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-04"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Improper privilege management in Jungo WinDriver before 12.2.0 allows local attackers to escalate privileges and execute arbitrary code."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-02T15:46:35.142278",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://jungo.com/windriver/versions/"
        },
        {
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-001_en.pdf"
        },
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-04"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-25086",
    "datePublished": "2024-07-02T00:00:00",
    "dateReserved": "2024-02-04T00:00:00",
    "dateUpdated": "2024-08-01T23:36:21.814Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-29827
Vulnerability from cvelistv5
Published
2022-11-24 23:22
Modified
2024-08-03 06:33
Summary
Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers may view programs and project files or execute programs illegally.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T06:33:42.827Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
          },
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://jvn.jp/vu/JVNVU97244961/index.html"
          },
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "GX Works3",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "from 1.000A and later"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers may view programs and project files or execute programs illegally."
            }
          ],
          "value": "Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers may view programs and project files or execute programs illegally."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-321",
              "description": "CWE-321 Use of Hard-coded Cryptographic Key",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-06-29T07:41:34.706Z",
        "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "shortName": "Mitsubishi"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://jvn.jp/vu/JVNVU97244961/index.html"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
    "assignerShortName": "Mitsubishi",
    "cveId": "CVE-2022-29827",
    "datePublished": "2022-11-24T23:22:43.489Z",
    "dateReserved": "2022-04-27T20:47:43.443Z",
    "dateUpdated": "2024-08-03T06:33:42.827Z",
    "requesterUserId": "520cc88b-a1c8-44f6-9154-21a4d74c769f",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-25087
Vulnerability from cvelistv5
Published
2024-07-02 00:00
Modified
2024-10-30 14:18
Severity ?
Summary
Denial of Service (DoS) vulnerability in Jungo WinDriver before 12.7.0 allows local attackers to cause a Windows blue screen error.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-25087",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-02T19:41:50.366484Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-404",
                "description": "CWE-404 Improper Resource Shutdown or Release",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-30T14:18:21.106Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T23:36:21.598Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://jungo.com/windriver/versions/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-001_en.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-04"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Denial of Service (DoS) vulnerability in Jungo WinDriver before 12.7.0 allows local attackers to cause a Windows blue screen error."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-02T15:47:33.372813",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://jungo.com/windriver/versions/"
        },
        {
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-001_en.pdf"
        },
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-04"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-25087",
    "datePublished": "2024-07-02T00:00:00",
    "dateReserved": "2024-02-04T00:00:00",
    "dateUpdated": "2024-10-30T14:18:21.106Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-29828
Vulnerability from cvelistv5
Published
2022-11-24 23:23
Modified
2024-08-03 06:33
Summary
Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers may view programs and project file or execute programs illegally.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T06:33:42.843Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
          },
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://jvn.jp/vu/JVNVU97244961/index.html"
          },
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "GX Works3",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "from 1.000A and later"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers may view programs and project file or execute programs illegally."
            }
          ],
          "value": "Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers may view programs and project file or execute programs illegally."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-321",
              "description": "CWE-321 Use of Hard-coded Cryptographic Key",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-06-29T07:42:00.661Z",
        "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "shortName": "Mitsubishi"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://jvn.jp/vu/JVNVU97244961/index.html"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
    "assignerShortName": "Mitsubishi",
    "cveId": "CVE-2022-29828",
    "datePublished": "2022-11-24T23:23:04.141Z",
    "dateReserved": "2022-04-27T20:47:43.443Z",
    "dateUpdated": "2024-08-03T06:33:42.843Z",
    "requesterUserId": "520cc88b-a1c8-44f6-9154-21a4d74c769f",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-5247
Vulnerability from cvelistv5
Published
2023-11-30 03:57
Modified
2024-12-02 19:02
Summary
Malicious Code Execution Vulnerability due to External Control of File Name or Path in multiple Mitsubishi Electric FA Engineering Software Products allows a malicious attacker to execute a malicious code by having legitimate users open a specially crafted project file, which could result in information disclosure, tampering and deletion, or a denial-of-service (DoS) condition.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T07:52:08.538Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-016_en.pdf"
          },
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://jvn.jp/vu/JVNVU93383160/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-5247",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-12-02T19:02:13.903376Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-12-02T19:02:32.708Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "GX Works3",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSOFT iQ AppPortal",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSOFT Navigator",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Motion Control Setting",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Malicious Code Execution Vulnerability due to External Control of File Name or Path in multiple Mitsubishi Electric FA Engineering Software Products allows a malicious attacker to execute a malicious code by having legitimate users open a specially crafted project file, which could result in information disclosure, tampering and deletion, or a denial-of-service (DoS) condition."
            }
          ],
          "value": "Malicious Code Execution Vulnerability due to External Control of File Name or Path in multiple Mitsubishi Electric FA Engineering Software Products allows a malicious attacker to execute a malicious code by having legitimate users open a specially crafted project file, which could result in information disclosure, tampering and deletion, or a denial-of-service (DoS) condition."
        }
      ],
      "impacts": [
        {
          "descriptions": [
            {
              "lang": "en",
              "value": "Malicious Code Execution"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-73",
              "description": "CWE-73  External Control of File Name or Path",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-11-30T03:57:30.083Z",
        "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "shortName": "Mitsubishi"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-016_en.pdf"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://jvn.jp/vu/JVNVU93383160/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
    "assignerShortName": "Mitsubishi",
    "cveId": "CVE-2023-5247",
    "datePublished": "2023-11-30T03:57:30.083Z",
    "dateReserved": "2023-09-28T07:26:44.445Z",
    "dateUpdated": "2024-12-02T19:02:32.708Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2020-5602
Vulnerability from cvelistv5
Published
2020-06-30 10:20
Modified
2024-08-04 08:30
Severity ?
Summary
Mitsubishi Electoric FA Engineering Software (CPU Module Logging Configuration Tool Ver. 1.94Y and earlier, CW Configurator Ver. 1.010L and earlier, EM Software Development Kit (EM Configurator) Ver. 1.010L and earlier, GT Designer3 (GOT2000) Ver. 1.221F and earlier, GX LogViewer Ver. 1.96A and earlier, GX Works2 Ver. 1.586L and earlier, GX Works3 Ver. 1.058L and earlier, M_CommDTM-HART Ver. 1.00A, M_CommDTM-IO-Link Ver. 1.02C and earlier, MELFA-Works Ver. 4.3 and earlier, MELSEC-L Flexible High-Speed I/O Control Module Configuration Tool Ver.1.004E and earlier, MELSOFT FieldDeviceConfigurator Ver. 1.03D and earlier, MELSOFT iQ AppPortal Ver. 1.11M and earlier, MELSOFT Navigator Ver. 2.58L and earlier, MI Configurator Ver. 1.003D and earlier, Motion Control Setting Ver. 1.005F and earlier, MR Configurator2 Ver. 1.72A and earlier, MT Works2 Ver. 1.156N and earlier, RT ToolBox2 Ver. 3.72A and earlier, and RT ToolBox3 Ver. 1.50C and earlier) allows an attacker to conduct XML External Entity (XXE) attacks via unspecified vectors.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T08:30:24.529Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-004_en.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://jvn.jp/en/vu/JVNVU90307594/index.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Mitsubishi Electoric FA Engineering Software",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "CPU Module Logging Configuration Tool Ver. 1.94Y and earlier, CW Configurator Ver. 1.010L and earlier, EM Software Development Kit (EM Configurator) Ver. 1.010L and earlier, GT Designer3 (GOT2000) Ver. 1.221F and earlier, GX LogViewer Ver. 1.96A and earlier, GX Works2 Ver. 1.586L and earlier, GX Works3 Ver. 1.058L and earlier, M_CommDTM-HART Ver. 1.00A, M_CommDTM-IO-Link Ver. 1.02C and earlier, MELFA-Works Ver. 4.3 and earlier, MELSEC-L Flexible High-Speed I/O Control Module Configuration Tool Ver.1.004E and earlier, MELSOFT FieldDeviceConfigurator Ver. 1.03D and earlier, MELSOFT iQ AppPortal Ver. 1.11M and earlier, MELSOFT Navigator Ver. 2.58L and earlier, MI Configurator Ver. 1.003D and earlier, Motion Control Setting Ver. 1.005F and earlier, MR Configurator2 Ver. 1.72A and earlier, MT Works2 Ver. 1.156N and earlier, RT ToolBox2 Ver. 3.72A and earlier, and RT ToolBox3 Ver. 1.50C and earlier"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Mitsubishi Electoric FA Engineering Software (CPU Module Logging Configuration Tool Ver. 1.94Y and earlier, CW Configurator Ver. 1.010L and earlier, EM Software Development Kit (EM Configurator) Ver. 1.010L and earlier, GT Designer3 (GOT2000) Ver. 1.221F and earlier, GX LogViewer Ver. 1.96A and earlier, GX Works2 Ver. 1.586L and earlier, GX Works3 Ver. 1.058L and earlier, M_CommDTM-HART Ver. 1.00A, M_CommDTM-IO-Link Ver. 1.02C and earlier, MELFA-Works Ver. 4.3 and earlier, MELSEC-L Flexible High-Speed I/O Control Module Configuration Tool Ver.1.004E and earlier, MELSOFT FieldDeviceConfigurator Ver. 1.03D and earlier, MELSOFT iQ AppPortal Ver. 1.11M and earlier, MELSOFT Navigator Ver. 2.58L and earlier, MI Configurator Ver. 1.003D and earlier, Motion Control Setting Ver. 1.005F and earlier, MR Configurator2 Ver. 1.72A and earlier, MT Works2 Ver. 1.156N and earlier, RT ToolBox2 Ver. 3.72A and earlier, and RT ToolBox3 Ver. 1.50C and earlier) allows an attacker to conduct XML External Entity (XXE) attacks via unspecified vectors."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "XML external entities (XXE)",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-06-30T10:20:45",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-004_en.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://jvn.jp/en/vu/JVNVU90307594/index.html"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "vultures@jpcert.or.jp",
          "ID": "CVE-2020-5602",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Mitsubishi Electoric FA Engineering Software",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "CPU Module Logging Configuration Tool Ver. 1.94Y and earlier, CW Configurator Ver. 1.010L and earlier, EM Software Development Kit (EM Configurator) Ver. 1.010L and earlier, GT Designer3 (GOT2000) Ver. 1.221F and earlier, GX LogViewer Ver. 1.96A and earlier, GX Works2 Ver. 1.586L and earlier, GX Works3 Ver. 1.058L and earlier, M_CommDTM-HART Ver. 1.00A, M_CommDTM-IO-Link Ver. 1.02C and earlier, MELFA-Works Ver. 4.3 and earlier, MELSEC-L Flexible High-Speed I/O Control Module Configuration Tool Ver.1.004E and earlier, MELSOFT FieldDeviceConfigurator Ver. 1.03D and earlier, MELSOFT iQ AppPortal Ver. 1.11M and earlier, MELSOFT Navigator Ver. 2.58L and earlier, MI Configurator Ver. 1.003D and earlier, Motion Control Setting Ver. 1.005F and earlier, MR Configurator2 Ver. 1.72A and earlier, MT Works2 Ver. 1.156N and earlier, RT ToolBox2 Ver. 3.72A and earlier, and RT ToolBox3 Ver. 1.50C and earlier"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Mitsubishi Electric Corporation"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Mitsubishi Electoric FA Engineering Software (CPU Module Logging Configuration Tool Ver. 1.94Y and earlier, CW Configurator Ver. 1.010L and earlier, EM Software Development Kit (EM Configurator) Ver. 1.010L and earlier, GT Designer3 (GOT2000) Ver. 1.221F and earlier, GX LogViewer Ver. 1.96A and earlier, GX Works2 Ver. 1.586L and earlier, GX Works3 Ver. 1.058L and earlier, M_CommDTM-HART Ver. 1.00A, M_CommDTM-IO-Link Ver. 1.02C and earlier, MELFA-Works Ver. 4.3 and earlier, MELSEC-L Flexible High-Speed I/O Control Module Configuration Tool Ver.1.004E and earlier, MELSOFT FieldDeviceConfigurator Ver. 1.03D and earlier, MELSOFT iQ AppPortal Ver. 1.11M and earlier, MELSOFT Navigator Ver. 2.58L and earlier, MI Configurator Ver. 1.003D and earlier, Motion Control Setting Ver. 1.005F and earlier, MR Configurator2 Ver. 1.72A and earlier, MT Works2 Ver. 1.156N and earlier, RT ToolBox2 Ver. 3.72A and earlier, and RT ToolBox3 Ver. 1.50C and earlier) allows an attacker to conduct XML External Entity (XXE) attacks via unspecified vectors."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "XML external entities (XXE)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-004_en.pdf",
              "refsource": "MISC",
              "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-004_en.pdf"
            },
            {
              "name": "https://jvn.jp/en/vu/JVNVU90307594/index.html",
              "refsource": "MISC",
              "url": "https://jvn.jp/en/vu/JVNVU90307594/index.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2020-5602",
    "datePublished": "2020-06-30T10:20:45",
    "dateReserved": "2020-01-06T00:00:00",
    "dateUpdated": "2024-08-04T08:30:24.529Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-51776
Vulnerability from cvelistv5
Published
2024-07-02 00:00
Modified
2024-08-02 22:48
Severity ?
Summary
Improper privilege management in Jungo WinDriver before 12.1.0 allows local attackers to escalate privileges and execute arbitrary code.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-51776",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-08T20:35:51.771087Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-08T20:35:57.576Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T22:48:11.179Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://jungo.com/windriver/versions/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-001_en.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-04"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Improper privilege management in Jungo WinDriver before 12.1.0 allows local attackers to escalate privileges and execute arbitrary code."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-02T15:40:36.672344",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://jungo.com/windriver/versions/"
        },
        {
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-001_en.pdf"
        },
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-04"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-51776",
    "datePublished": "2024-07-02T00:00:00",
    "dateReserved": "2023-12-25T00:00:00",
    "dateUpdated": "2024-08-02T22:48:11.179Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-4088
Vulnerability from cvelistv5
Published
2023-09-20 02:26
Modified
2024-09-24 18:27
Severity ?
Summary
Incorrect Default Permissions vulnerability in Mitsubishi Electric Corporation multiple FA engineering software products allows a malicious local attacker to execute a malicious code, resulting in information disclosure, tampering with and deletion, or a denial-of-service (DoS) condition, if the product is installed in a folder other than the default installation folder.
Impacted products
Vendor Product Version
Mitsubishi Electric Corporation AL-PCS/WIN-E Version: all versions
Mitsubishi Electric Corporation CPU Module Logging Configuration Tool Version: all versions
Mitsubishi Electric Corporation EZSocket Version: all versions
Mitsubishi Electric Corporation FR Configurator2 Version: all versions
Mitsubishi Electric Corporation FX Configurator-EN Version: all versions
Mitsubishi Electric Corporation FX Configurator-EN-L Version: all versions
Mitsubishi Electric Corporation FX Configurator-FP Version: all versions
Mitsubishi Electric Corporation GT Designer3 Version1(GOT1000) Version: all versions
Mitsubishi Electric Corporation GT Designer3 Version1(GOT2000) Version: all versions
Mitsubishi Electric Corporation GT SoftGOT1000 Version3 Version: all versions
Mitsubishi Electric Corporation GT SoftGOT2000 Version1 Version: all versions
Mitsubishi Electric Corporation GX LogViewer Version: all versions
Mitsubishi Electric Corporation GX Works2 Version: all versions
Mitsubishi Electric Corporation MELSOFT FieldDeviceConfigurator Version: all versions
Mitsubishi Electric Corporation MELSOFT iQ AppPortal Version: all versions
Mitsubishi Electric Corporation MELSOFT MaiLab Version: all versions
Mitsubishi Electric Corporation MELSOFT Navigator Version: all versions
Mitsubishi Electric Corporation MELSOFT Update Manager Version: all versions
Mitsubishi Electric Corporation MX Component Version: all versions
Mitsubishi Electric Corporation MX Sheet Version: all versions
Mitsubishi Electric Corporation PX Developer Version: all versions
Mitsubishi Electric Corporation RT ToolBox3 Version: all versions
Mitsubishi Electric Corporation RT VisualBox Version: all versions
Mitsubishi Electric Corporation Data Transfer Version: all versions
Mitsubishi Electric Corporation Data Transfer Classic Version: all versions
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T07:17:12.060Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-010_en.pdf"
          },
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://jvn.jp/vu/JVNVU96447193/index.html"
          },
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-269-03"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-4088",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-24T18:27:00.307770Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-24T18:27:11.655Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "GX Works3",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "AL-PCS/WIN-E",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CPU Module Logging Configuration Tool",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EZSocket",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "FR Configurator2",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "FX Configurator-EN",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "FX Configurator-EN-L",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "FX Configurator-FP",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GT Designer3 Version1(GOT1000)",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GT Designer3 Version1(GOT2000)",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GT SoftGOT1000 Version3",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GT SoftGOT2000 Version1",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GX LogViewer",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GX Works2",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSOFT FieldDeviceConfigurator",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSOFT iQ AppPortal",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSOFT MaiLab",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSOFT Navigator",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSOFT Update Manager",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MX Component",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MX Sheet",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "PX Developer",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "RT ToolBox3",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "RT VisualBox",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Data Transfer",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Data Transfer Classic",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Incorrect Default Permissions vulnerability in Mitsubishi Electric Corporation multiple FA engineering software products allows a malicious local attacker to execute a malicious code, resulting in information disclosure, tampering with and deletion, or a denial-of-service (DoS) condition, if the product is installed in a folder other than the default installation folder."
            }
          ],
          "value": "Incorrect Default Permissions vulnerability in Mitsubishi Electric Corporation multiple FA engineering software products allows a malicious local attacker to execute a malicious code, resulting in information disclosure, tampering with and deletion, or a denial-of-service (DoS) condition, if the product is installed in a folder other than the default installation folder."
        }
      ],
      "impacts": [
        {
          "descriptions": [
            {
              "lang": "en",
              "value": "Malicious Code Execution"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 9.3,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-276",
              "description": "CWE-276 Incorrect Default Permissions",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-04T09:16:28.950Z",
        "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "shortName": "Mitsubishi"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-010_en.pdf"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://jvn.jp/vu/JVNVU96447193/index.html"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-269-03"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Malicious Code Execution Vulnerability in FA Engineering Software Products",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
    "assignerShortName": "Mitsubishi",
    "cveId": "CVE-2023-4088",
    "datePublished": "2023-09-20T02:26:43.901Z",
    "dateReserved": "2023-08-02T04:52:49.923Z",
    "dateUpdated": "2024-09-24T18:27:11.655Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-29832
Vulnerability from cvelistv5
Published
2022-11-24 23:37
Modified
2024-08-03 06:33
Summary
Cleartext Storage of Sensitive Information in Memory vulnerability in Mitsubishi Electric Corporation GX Works3 versions 1.015R and later, GX Works2 all versions and GX Developer versions 8.40S and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users could obtain information about the project file for MELSEC safety CPU modules or project file for MELSEC Q/FX/L series with security setting.
Impacted products
Vendor Product Version
Mitsubishi Electric Corporation GX Works2 Version: all versions
Mitsubishi Electric Corporation GX Developer Version: 8.40S and later
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T06:33:42.792Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
          },
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://jvn.jp/vu/JVNVU97244961"
          },
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "GX Works3",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "1.015R and later"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GX Works2",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GX Developer",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "8.40S and later"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Cleartext Storage of Sensitive Information in Memory vulnerability in Mitsubishi Electric Corporation GX Works3 versions 1.015R and later, GX Works2 all versions and GX Developer versions 8.40S and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users could obtain information about the project file for MELSEC safety CPU modules or project file for MELSEC Q/FX/L series with security setting."
            }
          ],
          "value": "Cleartext Storage of Sensitive Information in Memory vulnerability in Mitsubishi Electric Corporation GX Works3 versions 1.015R and later, GX Works2 all versions and GX Developer versions 8.40S and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users could obtain information about the project file for MELSEC safety CPU modules or project file for MELSEC Q/FX/L series with security setting."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 3.7,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-316",
              "description": "CWE-316 Cleartext Storage of Sensitive Information in Memory",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-31T06:40:22.640Z",
        "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "shortName": "Mitsubishi"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://jvn.jp/vu/JVNVU97244961"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
    "assignerShortName": "Mitsubishi",
    "cveId": "CVE-2022-29832",
    "datePublished": "2022-11-24T23:37:41.044Z",
    "dateReserved": "2022-04-27T20:47:43.445Z",
    "dateUpdated": "2024-08-03T06:33:42.792Z",
    "requesterUserId": "520cc88b-a1c8-44f6-9154-21a4d74c769f",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-22104
Vulnerability from cvelistv5
Published
2024-07-02 00:00
Modified
2024-08-01 22:35
Summary
Out-of-Bounds Write vulnerability in Jungo WinDriver before 12.5.1 allows local attackers to cause a Windows blue screen error and Denial of Service (DoS).
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:jungo:windriver:12.5.1:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "windriver",
            "vendor": "jungo",
            "versions": [
              {
                "lessThan": "12.5.1",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 5.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-22104",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-03T14:47:59.796129Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-400",
                "description": "CWE-400 Uncontrolled Resource Consumption",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-03T14:51:19.389Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T22:35:34.727Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://jungo.com/windriver/versions/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-001_en.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-04"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Out-of-Bounds Write vulnerability in Jungo WinDriver before 12.5.1 allows local attackers to cause a Windows blue screen error and Denial of Service (DoS)."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-02T15:44:29.372340",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://jungo.com/windriver/versions/"
        },
        {
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-001_en.pdf"
        },
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-04"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-22104",
    "datePublished": "2024-07-02T00:00:00",
    "dateReserved": "2024-01-05T00:00:00",
    "dateUpdated": "2024-08-01T22:35:34.727Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-25088
Vulnerability from cvelistv5
Published
2024-07-02 00:00
Modified
2024-08-01 23:36
Summary
Improper privilege management in Jungo WinDriver before 12.5.1 allows local attackers to escalate privileges and execute arbitrary code.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:jungo:windriver:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "windriver",
            "vendor": "jungo",
            "versions": [
              {
                "lessThan": "12.5.1",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-25088",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-08T20:13:12.712262Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-269",
                "description": "CWE-269 Improper Privilege Management",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-31T15:40:12.180Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T23:36:21.646Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://jungo.com/windriver/versions/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-001_en.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-04"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Improper privilege management in Jungo WinDriver before 12.5.1 allows local attackers to escalate privileges and execute arbitrary code."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-02T15:48:12.787970",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://jungo.com/windriver/versions/"
        },
        {
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-001_en.pdf"
        },
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-04"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-25088",
    "datePublished": "2024-07-02T00:00:00",
    "dateReserved": "2024-02-04T00:00:00",
    "dateUpdated": "2024-08-01T23:36:21.646Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-22106
Vulnerability from cvelistv5
Published
2024-07-02 00:00
Modified
2024-08-01 22:35
Summary
Improper privilege management in Jungo WinDriver before 12.5.1 allows local attackers to escalate privileges, execute arbitrary code, or cause a Denial of Service (DoS).
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:jungo:windriver:12.5.1:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "windriver",
            "vendor": "jungo",
            "versions": [
              {
                "lessThan": "12.5.1",
                "status": "affected",
                "version": "0",
                "versionType": "semver"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "CHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-22106",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-02T21:21:41.420629Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-269",
                "description": "CWE-269 Improper Privilege Management",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-02T21:24:36.463Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T22:35:34.826Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://jungo.com/windriver/versions/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-001_en.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-04"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Improper privilege management in Jungo WinDriver before 12.5.1 allows local attackers to escalate privileges, execute arbitrary code, or cause a Denial of Service (DoS)."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-02T15:45:42.511740",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://jungo.com/windriver/versions/"
        },
        {
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-001_en.pdf"
        },
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-04"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-22106",
    "datePublished": "2024-07-02T00:00:00",
    "dateReserved": "2024-01-05T00:00:00",
    "dateUpdated": "2024-08-01T22:35:34.826Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-29829
Vulnerability from cvelistv5
Published
2022-11-24 23:23
Modified
2024-08-03 06:33
Summary
Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.090U, GT Designer3 Version1 (GOT2000) versions from 1.122C to 1.290C and Motion Control Setting(GX Works3 related software) versions from 1.035M to 1.042U allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users may view programs and project files or execute programs illegally.
Impacted products
Vendor Product Version
Mitsubishi Electric Corporation GT Designer3 Version1 (GOT2000) Version: from 1.122C to 1.290C
Mitsubishi Electric Corporation Motion Control Setting(GX Works3 related software) Version: from 1.035M to 1.042U
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T06:33:42.868Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
          },
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://jvn.jp/vu/JVNVU97244961/index.html"
          },
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "GX Works3",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "from 1.000A to 1.090U"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GT Designer3 Version1 (GOT2000)",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "from 1.122C to 1.290C"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Motion Control Setting(GX Works3 related software)",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "from 1.035M to 1.042U"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.090U, GT Designer3 Version1 (GOT2000) versions from 1.122C to 1.290C and Motion Control Setting(GX Works3 related software) versions from 1.035M to 1.042U allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users may view programs and project files or execute programs illegally."
            }
          ],
          "value": "Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.090U, GT Designer3 Version1 (GOT2000) versions from 1.122C to 1.290C and Motion Control Setting(GX Works3 related software) versions from 1.035M to 1.042U allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users may view programs and project files or execute programs illegally."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-321",
              "description": "CWE-321 Use of Hard-coded Cryptographic Key",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-31T08:41:10.662Z",
        "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "shortName": "Mitsubishi"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://jvn.jp/vu/JVNVU97244961/index.html"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
    "assignerShortName": "Mitsubishi",
    "cveId": "CVE-2022-29829",
    "datePublished": "2022-11-24T23:23:31.959Z",
    "dateReserved": "2022-04-27T20:47:43.443Z",
    "dateUpdated": "2024-08-03T06:33:42.868Z",
    "requesterUserId": "520cc88b-a1c8-44f6-9154-21a4d74c769f",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-26314
Vulnerability from cvelistv5
Published
2024-07-02 00:00
Modified
2024-08-02 00:07
Severity ?
Summary
Improper privilege management in Jungo WinDriver 6.0.0 through 16.1.0 allows local attackers to escalate privileges and execute arbitrary code.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:mitsubishielectric:cpu_module_logging_configuration_tool:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "cpu_module_logging_configuration_tool",
            "vendor": "mitsubishielectric",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:mitsubishielectric:gx_works2:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "gx_works2",
            "vendor": "mitsubishielectric",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:mitsubishielectric:cw_configurator:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "cw_configurator",
            "vendor": "mitsubishielectric",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:mitsubishielectric:data_transfer:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "data_transfer",
            "vendor": "mitsubishielectric",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:mitsubishielectric:ezsocket:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ezsocket",
            "vendor": "mitsubishielectric",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:mitsubishielectric:fr_configurator_sw3:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "fr_configurator_sw3",
            "vendor": "mitsubishielectric",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:mitsubishielectric:fr_configurator2:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "fr_configurator2",
            "vendor": "mitsubishielectric",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:iconics:genesis64:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "genesis64",
            "vendor": "iconics",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:mitsubishielectric:gt_designer3:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "gt_designer3",
            "vendor": "mitsubishielectric",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:mitsubishielectric:gt_softgot1000:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "gt_softgot1000",
            "vendor": "mitsubishielectric",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:mitsubishielectric:gt_softgot2000:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "gt_softgot2000",
            "vendor": "mitsubishielectric",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:mitsubishielectric:gx_developer:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "gx_developer",
            "vendor": "mitsubishielectric",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:mitsubishielectric:gx_logviewer:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "gx_logviewer",
            "vendor": "mitsubishielectric",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:mitsubishielectric:gx_works2:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "gx_works2",
            "vendor": "mitsubishielectric",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:mitsubishielectric:gx_works3:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "gx_works3",
            "vendor": "mitsubishielectric",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:mitsubishielectric:melsoft_navigator:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "melsoft_navigator",
            "vendor": "mitsubishielectric",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:mitsubishielectric:mi_configurator:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "mi_configurator",
            "vendor": "mitsubishielectric",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:mitsubishielectric:fcsb1224:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "fcsb1224",
            "vendor": "mitsubishielectric",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:mitsubishielectric:mr_configurator2:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "mr_configurator2",
            "vendor": "mitsubishielectric",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:mitsubishielectric:mrzjw3-mc2-utl:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "mrzjw3-mc2-utl",
            "vendor": "mitsubishielectric",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:mitsubishielectric:mx_component:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "mx_component",
            "vendor": "mitsubishielectric",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:mitsubishielectric:mx_opc_server_da\\/ua:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "mx_opc_server_da\\/ua",
            "vendor": "mitsubishielectric",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:mitsubishielectric:px_developer:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "px_developer",
            "vendor": "mitsubishielectric",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:mitsubishielectric:rt_toolbox3:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "rt_toolbox3",
            "vendor": "mitsubishielectric",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:mitsubishielectric:rt_visualbox:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "rt_visualbox",
            "vendor": "mitsubishielectric",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:mitsubishielectric:c_controller_module_setting_and_monitoring_tool:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "c_controller_module_setting_and_monitoring_tool",
            "vendor": "mitsubishielectric",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:mitsubishielectric:sw0dnc-mneth-b:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sw0dnc-mneth-b",
            "vendor": "mitsubishielectric",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:mitsubishielectric:sw1dnc-ccbd2-b:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sw1dnc-ccbd2-b",
            "vendor": "mitsubishielectric",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:mitsubishielectric:sw1dnc-ccief-j:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sw1dnc-ccief-j",
            "vendor": "mitsubishielectric",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:mitsubishielectric:sw1dnc-ccief-b:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sw1dnc-ccief-b",
            "vendor": "mitsubishielectric",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:mitsubishielectric:sw1dnc-mnetg-b:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sw1dnc-mnetg-b",
            "vendor": "mitsubishielectric",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:mitsubishielectric:sw1dnc-qsccf-b:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sw1dnc-qsccf-b",
            "vendor": "mitsubishielectric",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:mitsubishielectric:sw1dnd-emsdk-b:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sw1dnd-emsdk-b",
            "vendor": "mitsubishielectric",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-26314",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-09T16:03:22.624752Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-09T17:46:04.803Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T00:07:19.173Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://jungo.com/windriver/versions/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-001_en.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-04"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Improper privilege management in Jungo WinDriver 6.0.0 through 16.1.0 allows local attackers to escalate privileges and execute arbitrary code."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-02T15:39:18.038388",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://jungo.com/windriver/versions/"
        },
        {
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-001_en.pdf"
        },
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-04"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-26314",
    "datePublished": "2024-07-02T00:00:00",
    "dateReserved": "2024-02-19T00:00:00",
    "dateUpdated": "2024-08-02T00:07:19.173Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-51777
Vulnerability from cvelistv5
Published
2024-07-02 00:00
Modified
2024-10-28 01:36
Summary
Denial of Service (DoS) vulnerability in Jungo WinDriver before 12.1.0 allows local attackers to cause a Windows blue screen error.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 5.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2023-51777",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-05T15:21:05.227409Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "description": "CWE-noinfo Not enough information",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-28T01:36:09.405Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T22:48:11.361Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://jungo.com/windriver/versions/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-001_en.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-04"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Denial of Service (DoS) vulnerability in Jungo WinDriver before 12.1.0 allows local attackers to cause a Windows blue screen error."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-02T15:41:24.936205",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://jungo.com/windriver/versions/"
        },
        {
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-001_en.pdf"
        },
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-04"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-51777",
    "datePublished": "2024-07-02T00:00:00",
    "dateReserved": "2023-12-25T00:00:00",
    "dateUpdated": "2024-10-28T01:36:09.405Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-6943
Vulnerability from cvelistv5
Published
2024-01-30 09:09
Modified
2024-11-01 08:36
Severity ?
Summary
Use of Externally-Controlled Input to Select Classes or Code ('Unsafe Reflection') vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 and later, GT Designer3 Version1(GOT1000) all versions, GT Designer3 Version1(GOT2000) all versions, GX Works2 versions 1.11M and later, GX Works3 versions 1.106L and prior, MELSOFT Navigator versions 1.04E and later, MT Works2 all versions, MX Component versions 4.00A and later and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to execute a malicious code by RPC with a path to a malicious library while connected to the products.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T08:42:08.552Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-020_en.pdf"
          },
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://jvn.jp/vu/JVNVU95103362"
          },
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-030-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "EZSocket",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "3.0 and later"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GT Designer3 Version1(GOT1000)",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GT Designer3 Version1(GOT2000)",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GX Works2",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "1.11M and later"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GX Works3",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "1.106L and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSOFT Navigator",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "1.04E and later"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MT Works2",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MX Component",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "4.00A and later"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MX OPC Server DA/UA",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Use of Externally-Controlled Input to Select Classes or Code (\u0027Unsafe Reflection\u0027) vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 and later, GT Designer3 Version1(GOT1000) all versions, GT Designer3 Version1(GOT2000) all versions, GX Works2 versions 1.11M and later, GX Works3 versions 1.106L and prior, MELSOFT Navigator versions 1.04E and later, MT Works2 all versions, MX Component versions 4.00A and later and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to execute a malicious code by RPC with a path to a malicious library while connected to the products."
            }
          ],
          "value": "Use of Externally-Controlled Input to Select Classes or Code (\u0027Unsafe Reflection\u0027) vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 and later, GT Designer3 Version1(GOT1000) all versions, GT Designer3 Version1(GOT2000) all versions, GX Works2 versions 1.11M and later, GX Works3 versions 1.106L and prior, MELSOFT Navigator versions 1.04E and later, MT Works2 all versions, MX Component versions 4.00A and later and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to execute a malicious code by RPC with a path to a malicious library while connected to the products."
        }
      ],
      "impacts": [
        {
          "descriptions": [
            {
              "lang": "en",
              "value": "Remote Code Execution"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-470",
              "description": "CWE-470 Use of Externally-Controlled Input to Select Classes or Code (\u0027Unsafe Reflection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-01T08:36:32.008Z",
        "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "shortName": "Mitsubishi"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-020_en.pdf"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://jvn.jp/vu/JVNVU95103362"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-030-02"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
    "assignerShortName": "Mitsubishi",
    "cveId": "CVE-2023-6943",
    "datePublished": "2024-01-30T09:09:29.248Z",
    "dateReserved": "2023-12-19T08:00:07.140Z",
    "dateUpdated": "2024-11-01T08:36:32.008Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2020-14496
Vulnerability from cvelistv5
Published
2022-05-19 17:24
Modified
2024-08-04 12:46
Summary
Successful exploitation of this vulnerability for multiple Mitsubishi Electric Factory Automation Engineering Software Products of various versions could allow an attacker to escalate privilege and execute malicious programs, which could cause a denial-of-service condition, and allow information to be disclosed, tampered with, and/or destroyed.
References
Impacted products
Vendor Product Version
Mitsubishi Electric CW Configurator Version: All   <
Mitsubishi Electric Data Transfer Version: All   <
Mitsubishi Electric EZSocket Version: All   <
Mitsubishi Electric FR Configurator2 Version: All   <
Mitsubishi Electric GT Designer3 Version1 (GOT2000) Version: All   <
Mitsubishi Electric GT SoftGOT1000 Version3 Version: All   <
Mitsubishi Electric GT SoftGOT1000 Version3 Version: All
Mitsubishi Electric GT SoftGOT2000 Version1 Version: All   <
Mitsubishi Electric GX LogViewer Version: All   <
Mitsubishi Electric GX Works2 Version: All   <
Mitsubishi Electric GX Works3 Version: All   <
Mitsubishi Electric M_CommDTM-HART Version: All 1.00A
Mitsubishi Electric M_CommDTM-IO-Link Version: All
Mitsubishi Electric MELFA-Works Version: All   <
Mitsubishi Electric MELSEC WinCPU Setting Utility Version: All
Mitsubishi Electric MELSOFT EM Software Development Kit (EM Configurator) Version: All   <
Mitsubishi Electric MELSOFT FieldDeviceConfigurator Version: All   <
Mitsubishi Electric MELSOFT Navigator Version: All   <
Mitsubishi Electric MH11 SettingTool Version2 Version: All   <
Mitsubishi Electric MI Configurator Version: All
Mitsubishi Electric Motorizer Version: All   <
Mitsubishi Electric MR Configurator2 Version: All   <
Mitsubishi Electric MT Works2 Version: All   <
Mitsubishi Electric MX Component Version: All   <
Mitsubishi Electric Network Interface Board CC IE Control utility Version: All
Mitsubishi Electric Network Interface Board CC IE Field Utility Version: All
Mitsubishi Electric Network Interface Board CC-Link Ver.2 Utility Version: All
Mitsubishi Electric Network Interface Board MNETH utility Version: All
Mitsubishi Electric PX Developer Version: All   <
Mitsubishi Electric RT ToolBox2 Version: All   <
Mitsubishi Electric RT ToolBox3 Version: All   <
Mitsubishi Electric Setting/monitoring tools for the C Controller module Version: All
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T12:46:34.676Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "CPU Module Logging Configuration Tool",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "1.100E",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CW Configurator",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "1.010L",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Data Transfer",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "3.40S",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "EZSocket",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "4.5",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "FR Configurator2",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "1.22Y",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "GT Designer3 Version1 (GOT2000)",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "1.235V",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "GT SoftGOT1000 Version3",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "3.200J",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "GT SoftGOT1000 Version3",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "All"
            }
          ]
        },
        {
          "product": "GT SoftGOT2000 Version1",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "1.235V",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "GX LogViewer",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "1.100E",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "GX Works2",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "1.592S",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "GX Works3",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "1.063R",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "M_CommDTM-HART",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "All 1.00A"
            }
          ]
        },
        {
          "product": "M_CommDTM-IO-Link",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "All"
            }
          ]
        },
        {
          "product": "MELFA-Works",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "4.3",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "MELSEC WinCPU Setting Utility",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "All"
            }
          ]
        },
        {
          "product": "MELSOFT EM Software Development Kit (EM Configurator)",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "1.010L",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "MELSOFT FieldDeviceConfigurator",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "1.03D",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "MELSOFT Navigator",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "2.62Q",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "MH11 SettingTool Version2",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "2.002C",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "MI Configurator",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "All"
            }
          ]
        },
        {
          "product": "Motorizer",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "1.005F",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "MR Configurator2",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "1.105K",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "MT Works2",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "1.156N",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "MX Component",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "4.19V",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Network Interface Board CC IE Control utility",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "All"
            }
          ]
        },
        {
          "product": "Network Interface Board CC IE Field Utility",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "All"
            }
          ]
        },
        {
          "product": "Network Interface Board CC-Link Ver.2 Utility",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "All"
            }
          ]
        },
        {
          "product": "Network Interface Board MNETH utility",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "All"
            }
          ]
        },
        {
          "product": "PX Developer",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "1.52E",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "RT ToolBox2",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "3.72A",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "RT ToolBox3",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "1.70Y",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Setting/monitoring tools for the C Controller module",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "All"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Successful exploitation of this vulnerability for multiple Mitsubishi Electric Factory Automation Engineering Software Products of various versions could allow an attacker to escalate privilege and execute malicious programs, which could cause a denial-of-service condition, and allow information to be disclosed, tampered with, and/or destroyed."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-275",
              "description": "CWE-275 Permission Issues",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-05-19T17:24:43",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-02"
        }
      ],
      "source": {
        "advisory": "ICSA-20-212-02",
        "discovery": "UNKNOWN"
      },
      "title": "Mitsubishi Electric Multiple Factory Automation Engineering Software Products (Update A) - Permission Issues",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2020-14496",
          "STATE": "PUBLIC",
          "TITLE": "Mitsubishi Electric Multiple Factory Automation Engineering Software Products (Update A) - Permission Issues"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "CPU Module Logging Configuration Tool",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "All",
                            "version_value": "1.100E"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CW Configurator",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "All",
                            "version_value": "1.010L"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Data Transfer",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "All",
                            "version_value": "3.40S"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "EZSocket",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "All",
                            "version_value": "4.5"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "FR Configurator2",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "All",
                            "version_value": "1.22Y"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "GT Designer3 Version1 (GOT2000)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "All",
                            "version_value": "1.235V"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "GT SoftGOT1000 Version3",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "All",
                            "version_value": "3.200J"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "GT SoftGOT1000 Version3",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_name": "All",
                            "version_value": "All"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "GT SoftGOT2000 Version1",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "All",
                            "version_value": "1.235V"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "GX LogViewer",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "All",
                            "version_value": "1.100E"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "GX Works2",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "All",
                            "version_value": "1.592S"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "GX Works3",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "All",
                            "version_value": "1.063R"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "M_CommDTM-HART",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_name": "All",
                            "version_value": "1.00A"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "M_CommDTM-IO-Link",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_name": "All",
                            "version_value": "All"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "MELFA-Works",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "All",
                            "version_value": "4.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "MELSEC WinCPU Setting Utility",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_name": "All",
                            "version_value": "All"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "MELSOFT EM Software Development Kit (EM Configurator)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "All",
                            "version_value": "1.010L"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "MELSOFT FieldDeviceConfigurator",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "All",
                            "version_value": "1.03D"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "MELSOFT Navigator",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "All",
                            "version_value": "2.62Q"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "MH11 SettingTool Version2",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "All",
                            "version_value": "2.002C"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "MI Configurator",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_name": "All",
                            "version_value": "All"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Motorizer",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "All",
                            "version_value": "1.005F"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "MR Configurator2",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "All",
                            "version_value": "1.105K"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "MT Works2",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "All",
                            "version_value": "1.156N"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "MX Component",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "All",
                            "version_value": "4.19V"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Network Interface Board CC IE Control utility",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_name": "All",
                            "version_value": "All"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Network Interface Board CC IE Field Utility",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_name": "All",
                            "version_value": "All"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Network Interface Board CC-Link Ver.2 Utility",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_name": "All",
                            "version_value": "All"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Network Interface Board MNETH utility",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_name": "All",
                            "version_value": "All"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "PX Developer",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "All",
                            "version_value": "1.52E"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "RT ToolBox2",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "All",
                            "version_value": "3.72A"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "RT ToolBox3",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "All",
                            "version_value": "1.70Y"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Setting/monitoring tools for the C Controller module",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_name": "All",
                            "version_value": "All"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Mitsubishi Electric"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Successful exploitation of this vulnerability for multiple Mitsubishi Electric Factory Automation Engineering Software Products of various versions could allow an attacker to escalate privilege and execute malicious programs, which could cause a denial-of-service condition, and allow information to be disclosed, tampered with, and/or destroyed."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-275 Permission Issues"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-02",
              "refsource": "MISC",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-02"
            }
          ]
        },
        "source": {
          "advisory": "ICSA-20-212-02",
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2020-14496",
    "datePublished": "2022-05-19T17:24:43",
    "dateReserved": "2020-06-19T00:00:00",
    "dateUpdated": "2024-08-04T12:46:34.676Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-20588
Vulnerability from cvelistv5
Published
2021-02-19 19:58
Modified
2024-08-03 17:45
Severity ?
Summary
Improper handling of length parameter inconsistency vulnerability in Mitsubishi Electric FA Engineering Software(CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT SoftGOT1000 Version3 versions 3.245F and prior, GT SoftGOT2000 Version1 versions 1.250L and prior, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer versions 8.506C and prior, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer versions 1.115U and prior, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, iQ Monozukuri ANDON (Data Transfer) all versions, iQ Monozukuri Process Remote Monitoring (Data Transfer) all versions, M_CommDTM-HART all versions, M_CommDTM-IO-Link versions 1.03D and prior, MELFA-Works versions 4.4 and prior, MELSEC WinCPU Setting Utility all versions, MELSOFT EM Software Development Kit (EM Configurator) versions 1.015R and prior, MELSOFT Navigator versions 2.74C and prior, MH11 SettingTool Version2 versions 2.004E and prior, MI Configurator versions 1.004E and prior, MT Works2 versions 1.167Z and prior, MX Component versions 5.001B and prior, Network Interface Board CC IE Control utility versions 1.29F and prior, Network Interface Board CC IE Field Utility versions 1.16S and prior, Network Interface Board CC-Link Ver.2 Utility versions 1.23Z and prior, Network Interface Board MNETH utility versions 34L and prior, PX Developer versions 1.53F and prior, RT ToolBox2 versions 3.73B and prior, RT ToolBox3 versions 1.82L and prior, Setting/monitoring tools for the C Controller module (SW4PVC-CCPU) versions 4.12N and prior and SLMP Data Collector versions 1.04E and prior) allows a remote unauthenticated attacker to cause a DoS condition of the software products, and possibly to execute a malicious program on the personal computer running the software products although it has not been reproduced, by spoofing MELSEC, GOT or FREQROL and returning crafted reply packets.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T17:45:44.696Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-021_en.pdf"
          },
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://jvn.jp/vu/JVNVU92330101/index.html"
          },
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-049-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "FA Engineering Software",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "CPU Module Logging Configuration Tool versions 1.112R and prior"
            },
            {
              "status": "affected",
              "version": "CW Configurator versions 1.011M and prior"
            },
            {
              "status": "affected",
              "version": "Data Transfer versions 3.44W and prior"
            },
            {
              "status": "affected",
              "version": "EZSocket versions 5.4 and prior"
            },
            {
              "status": "affected",
              "version": "FR Configurator all versions"
            },
            {
              "status": "affected",
              "version": "FR Configurator SW3 all versions"
            },
            {
              "status": "affected",
              "version": "FR Configurator2 versions 1.24A and prior"
            },
            {
              "status": "affected",
              "version": "GT Designer3 Version1(GOT1000) versions 1.250L and prior"
            },
            {
              "status": "affected",
              "version": "GT Designer3 Version1(GOT2000) versions 1.250L and prior"
            },
            {
              "status": "affected",
              "version": "GT SoftGOT1000 Version3 versions 3.245F and prior"
            },
            {
              "status": "affected",
              "version": "GT SoftGOT2000 Version1 versions 1.250L and prior"
            },
            {
              "status": "affected",
              "version": "GX Configurator-DP versions 7.14Q and prior"
            },
            {
              "status": "affected",
              "version": "GX Configurator-QP all versions"
            },
            {
              "status": "affected",
              "version": "GX Developer versions 8.506C and prior"
            },
            {
              "status": "affected",
              "version": "GX Explorer all versions"
            },
            {
              "status": "affected",
              "version": "GX IEC Developer all versions"
            },
            {
              "status": "affected",
              "version": "GX LogViewer versions 1.115U and prior"
            },
            {
              "status": "affected",
              "version": "GX RemoteService-I all versions"
            },
            {
              "status": "affected",
              "version": "GX Works2 versions 1.597X and prior"
            },
            {
              "status": "affected",
              "version": "GX Works3 versions 1.070Y and prior"
            },
            {
              "status": "affected",
              "version": "iQ Monozukuri ANDON (Data Transfer) all versions"
            },
            {
              "status": "affected",
              "version": "iQ Monozukuri Process Remote Monitoring (Data Transfer) all versions"
            },
            {
              "status": "affected",
              "version": "M_CommDTM-HART all versions"
            },
            {
              "status": "affected",
              "version": "M_CommDTM-IO-Link versions 1.03D and prior"
            },
            {
              "status": "affected",
              "version": "MELFA-Works versions 4.4 and prior"
            },
            {
              "status": "affected",
              "version": "MELSEC WinCPU Setting Utility all versions"
            },
            {
              "status": "affected",
              "version": "MELSOFT EM Software Development Kit (EM Configurator) versions 1.015R and prior"
            },
            {
              "status": "affected",
              "version": "MELSOFT Navigator versions 2.74C and prior"
            },
            {
              "status": "affected",
              "version": "MH11 SettingTool Version2 versions 2.004E and prior"
            },
            {
              "status": "affected",
              "version": "MI Configurator versions 1.004E and prior"
            },
            {
              "status": "affected",
              "version": "MT Works2 versions 1.167Z and prior"
            },
            {
              "status": "affected",
              "version": "MX Component versions 5.001B and prior"
            },
            {
              "status": "affected",
              "version": "Network Interface Board CC IE Control utility versions 1.29F and prior"
            },
            {
              "status": "affected",
              "version": "Network Interface Board CC IE Field Utility versions 1.16S and prior"
            },
            {
              "status": "affected",
              "version": "Network Interface Board CC-Link Ver.2 Utility versions 1.23Z and prior"
            },
            {
              "status": "affected",
              "version": "Network Interface Board MNETH utility versions 34L and prior"
            },
            {
              "status": "affected",
              "version": "PX Developer versions 1.53F and prior"
            },
            {
              "status": "affected",
              "version": "RT ToolBox2 versions 3.73B and prior"
            },
            {
              "status": "affected",
              "version": "RT ToolBox3 versions 1.82L and prior"
            },
            {
              "status": "affected",
              "version": "Setting/monitoring tools for the C Controller module (SW4PVC-CCPU) versions 4.12N and prior"
            },
            {
              "status": "affected",
              "version": "SLMP Data Collector versions 1.04E and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Improper handling of length parameter inconsistency vulnerability in Mitsubishi Electric FA Engineering Software(CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT SoftGOT1000 Version3 versions 3.245F and prior, GT SoftGOT2000 Version1 versions 1.250L and prior, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer versions 8.506C and prior, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer versions 1.115U and prior, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, iQ Monozukuri ANDON (Data Transfer) all versions, iQ Monozukuri Process Remote Monitoring (Data Transfer) all versions, M_CommDTM-HART all versions, M_CommDTM-IO-Link versions 1.03D and prior, MELFA-Works versions 4.4 and prior, MELSEC WinCPU Setting Utility all versions, MELSOFT EM Software Development Kit (EM Configurator) versions 1.015R and prior, MELSOFT Navigator versions 2.74C and prior, MH11 SettingTool Version2 versions 2.004E and prior, MI Configurator versions 1.004E and prior, MT Works2 versions 1.167Z and prior, MX Component versions 5.001B and prior, Network Interface Board CC IE Control utility versions 1.29F and prior, Network Interface Board CC IE Field Utility versions 1.16S and prior, Network Interface Board CC-Link Ver.2 Utility versions 1.23Z and prior, Network Interface Board MNETH utility versions 34L and prior, PX Developer versions 1.53F and prior, RT ToolBox2 versions 3.73B and prior, RT ToolBox3 versions 1.82L and prior, Setting/monitoring tools for the C Controller module (SW4PVC-CCPU) versions 4.12N and prior and SLMP Data Collector versions 1.04E and prior) allows a remote unauthenticated attacker to cause a DoS condition of the software products, and possibly to execute a malicious program on the personal computer running the software products although it has not been reproduced, by spoofing MELSEC, GOT or FREQROL and returning crafted reply packets."
            }
          ],
          "value": "Improper handling of length parameter inconsistency vulnerability in Mitsubishi Electric FA Engineering Software(CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT SoftGOT1000 Version3 versions 3.245F and prior, GT SoftGOT2000 Version1 versions 1.250L and prior, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer versions 8.506C and prior, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer versions 1.115U and prior, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, iQ Monozukuri ANDON (Data Transfer) all versions, iQ Monozukuri Process Remote Monitoring (Data Transfer) all versions, M_CommDTM-HART all versions, M_CommDTM-IO-Link versions 1.03D and prior, MELFA-Works versions 4.4 and prior, MELSEC WinCPU Setting Utility all versions, MELSOFT EM Software Development Kit (EM Configurator) versions 1.015R and prior, MELSOFT Navigator versions 2.74C and prior, MH11 SettingTool Version2 versions 2.004E and prior, MI Configurator versions 1.004E and prior, MT Works2 versions 1.167Z and prior, MX Component versions 5.001B and prior, Network Interface Board CC IE Control utility versions 1.29F and prior, Network Interface Board CC IE Field Utility versions 1.16S and prior, Network Interface Board CC-Link Ver.2 Utility versions 1.23Z and prior, Network Interface Board MNETH utility versions 34L and prior, PX Developer versions 1.53F and prior, RT ToolBox2 versions 3.73B and prior, RT ToolBox3 versions 1.82L and prior, Setting/monitoring tools for the C Controller module (SW4PVC-CCPU) versions 4.12N and prior and SLMP Data Collector versions 1.04E and prior) allows a remote unauthenticated attacker to cause a DoS condition of the software products, and possibly to execute a malicious program on the personal computer running the software products although it has not been reproduced, by spoofing MELSEC, GOT or FREQROL and returning crafted reply packets."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Improper handling of length parameter inconsistency",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-10-17T23:30:16.586Z",
        "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "shortName": "Mitsubishi"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-021_en.pdf"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://jvn.jp/vu/JVNVU92330101/index.html"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-049-02"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
    "assignerShortName": "Mitsubishi",
    "cveId": "CVE-2021-20588",
    "datePublished": "2021-02-19T19:58:29.101118Z",
    "dateReserved": "2020-12-17T00:00:00",
    "dateUpdated": "2024-08-03T17:45:44.696Z",
    "serial": 1,
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-22105
Vulnerability from cvelistv5
Published
2024-07-02 00:00
Modified
2024-10-30 18:02
Severity ?
Summary
Denial of Service (DoS) vulnerability in Jungo WinDriver before 12.5.1 allows local attackers to cause a Windows blue screen error.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-22105",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-02T19:42:22.254120Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-404",
                "description": "CWE-404 Improper Resource Shutdown or Release",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-30T18:02:22.759Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T22:35:34.819Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://jungo.com/windriver/versions/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-001_en.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-04"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Denial of Service (DoS) vulnerability in Jungo WinDriver before 12.5.1 allows local attackers to cause a Windows blue screen error."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-02T15:45:08.292960",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://jungo.com/windriver/versions/"
        },
        {
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-001_en.pdf"
        },
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-04"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-22105",
    "datePublished": "2024-07-02T00:00:00",
    "dateReserved": "2024-01-05T00:00:00",
    "dateUpdated": "2024-10-30T18:02:22.759Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-29830
Vulnerability from cvelistv5
Published
2022-11-24 23:23
Modified
2024-08-03 06:33
Severity ?
Summary
Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Motion Control Setting(GX Works3 related software) versions from 1.000A and later allows a remote unauthenticated attacker to disclose or tamper with sensitive information. As a result, unauthenticated attackers may obtain information about project files illegally.
Impacted products
Vendor Product Version
Mitsubishi Electric Corporation Motion Control Setting(GX Works3 related software) Version: from 1.000A and later
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T06:33:43.144Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
          },
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://jvn.jp/vu/JVNVU97244961/index.html"
          },
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "GX Works3",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "from 1.000A to 1.095Z"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Motion Control Setting(GX Works3 related software)",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "from 1.000A and later"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Motion Control Setting(GX Works3 related software) versions from 1.000A and later allows a remote unauthenticated attacker to disclose or tamper with sensitive information. As a result, unauthenticated attackers may obtain information about project files illegally."
            }
          ],
          "value": "Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Motion Control Setting(GX Works3 related software) versions from 1.000A and later allows a remote unauthenticated attacker to disclose or tamper with sensitive information. As a result, unauthenticated attackers may obtain information about project files illegally."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-321",
              "description": "CWE-321 Use of Hard-coded Cryptographic Key",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-06-29T07:42:35.363Z",
        "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "shortName": "Mitsubishi"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://jvn.jp/vu/JVNVU97244961/index.html"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
    "assignerShortName": "Mitsubishi",
    "cveId": "CVE-2022-29830",
    "datePublished": "2022-11-24T23:23:51.967Z",
    "dateReserved": "2022-04-27T20:47:43.443Z",
    "dateUpdated": "2024-08-03T06:33:43.144Z",
    "requesterUserId": "520cc88b-a1c8-44f6-9154-21a4d74c769f",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-22102
Vulnerability from cvelistv5
Published
2024-07-02 00:00
Modified
2024-08-01 22:35
Severity ?
Summary
Denial of Service (DoS) vulnerability in Jungo WinDriver before 12.6.0 allows local attackers to cause a Windows blue screen error.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-22102",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-02T15:41:36.140573Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-02T15:41:46.989Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T22:35:34.840Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://jungo.com/windriver/versions/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-001_en.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-04"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Denial of Service (DoS) vulnerability in Jungo WinDriver before 12.6.0 allows local attackers to cause a Windows blue screen error."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-02T15:42:59.370727",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://jungo.com/windriver/versions/"
        },
        {
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-001_en.pdf"
        },
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-04"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-22102",
    "datePublished": "2024-07-02T00:00:00",
    "dateReserved": "2024-01-05T00:00:00",
    "dateUpdated": "2024-08-01T22:35:34.840Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-22103
Vulnerability from cvelistv5
Published
2024-07-02 00:00
Modified
2024-08-01 22:35
Summary
Out-of-Bounds Write vulnerability in Jungo WinDriver before 12.6.0 allows local attackers to cause a Windows blue screen error and Denial of Service (DoS).
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:jungo:windriver:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "windriver",
            "vendor": "jungo",
            "versions": [
              {
                "lessThan": "12.6.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "HIGH",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 4.4,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:N/I:N/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-22103",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-02T18:49:22.001562Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-787",
                "description": "CWE-787 Out-of-bounds Write",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-02T18:54:12.081Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T22:35:34.690Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://jungo.com/windriver/versions/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-001_en.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-04"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Out-of-Bounds Write vulnerability in Jungo WinDriver before 12.6.0 allows local attackers to cause a Windows blue screen error and Denial of Service (DoS)."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-02T15:43:45.109251",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://jungo.com/windriver/versions/"
        },
        {
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-001_en.pdf"
        },
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-04"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-22103",
    "datePublished": "2024-07-02T00:00:00",
    "dateReserved": "2024-01-05T00:00:00",
    "dateUpdated": "2024-08-01T22:35:34.690Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-51778
Vulnerability from cvelistv5
Published
2024-07-02 00:00
Modified
2024-08-02 22:48
Severity ?
Summary
Out-of-Bounds Write vulnerability in Jungo WinDriver before 12.1.0 allows local attackers to cause a Windows blue screen error and Denial of Service (DoS).
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-51778",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-23T15:40:06.299349Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-23T15:40:15.966Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T22:48:11.361Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://jungo.com/windriver/versions/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-001_en.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-04"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Out-of-Bounds Write vulnerability in Jungo WinDriver before 12.1.0 allows local attackers to cause a Windows blue screen error and Denial of Service (DoS)."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-02T15:42:00.481680",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://jungo.com/windriver/versions/"
        },
        {
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-001_en.pdf"
        },
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-04"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-51778",
    "datePublished": "2024-07-02T00:00:00",
    "dateReserved": "2023-12-25T00:00:00",
    "dateUpdated": "2024-08-02T22:48:11.361Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-29826
Vulnerability from cvelistv5
Published
2022-11-24 23:22
Modified
2024-08-03 06:33
Summary
Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.087R and Motion Control Setting(GX Works3 related software) versions from 1.000A to 1.042U allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users may view programs and project files or execute programs illegally.
Impacted products
Vendor Product Version
Mitsubishi Electric Corporation Motion Control Setting(GX Works3 related software) Version: from 1.000A to 1.042U
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T06:33:42.804Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
          },
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://jvn.jp/vu/JVNVU97244961/index.html"
          },
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "GX Works3",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "from 1.000A to 1.087R"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Motion Control Setting(GX Works3 related software)",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "from 1.000A to 1.042U"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.087R and Motion Control Setting(GX Works3 related software) versions from 1.000A to 1.042U allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users may view programs and project files or execute programs illegally."
            }
          ],
          "value": "Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.087R and Motion Control Setting(GX Works3 related software) versions from 1.000A to 1.042U allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users may view programs and project files or execute programs illegally."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "CWE-312 Cleartext Storage of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-06-27T05:19:57.479Z",
        "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "shortName": "Mitsubishi"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://jvn.jp/vu/JVNVU97244961/index.html"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
    "assignerShortName": "Mitsubishi",
    "cveId": "CVE-2022-29826",
    "datePublished": "2022-11-24T23:22:21.828Z",
    "dateReserved": "2022-04-27T20:47:43.442Z",
    "dateUpdated": "2024-08-03T06:33:42.804Z",
    "requesterUserId": "520cc88b-a1c8-44f6-9154-21a4d74c769f",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2020-14523
Vulnerability from cvelistv5
Published
2022-02-11 17:40
Modified
2024-09-16 23:36
Summary
Multiple Mitsubishi Electric Factory Automation products have a vulnerability that allows an attacker to execute arbitrary code.
Impacted products
Vendor Product Version
Mitsubishi Electric FR Configurator2 Version: unspecified   <
Mitsubishi Electric GX Works2 Version: unspecified   <
Mitsubishi Electric GX Works3 Version: unspecified   <
Mitsubishi Electric MELSOFT iQ AppPortal Version: unspecified   <
Mitsubishi Electric MELSOFT Navigator Version: unspecified   <
Mitsubishi Electric MI Configurator Version: All Versions
Mitsubishi Electric MR Configurator2 Version: unspecified   <
Mitsubishi Electric MT Works2 Version: unspecified   <
Mitsubishi Electric MX Component Version: unspecified   <
Mitsubishi Electric RT ToolBox3 Version: unspecified   <
Mitsubishi Electric MELSEC iQ-R Series Motion Module Version: unspecified   <
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T12:46:34.640Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://jvn.jp/vu/JVNVU90224831/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "CW Configurator",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Version 1.010L",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "FR Configurator2",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Version 1.22Y",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "GX Works2",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Version 1.595V",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "GX Works3",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Version 1.063R",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "MELSOFT iQ AppPortal",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Version 1.17T",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "MELSOFT Navigator",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Version2.70Y",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "MI Configurator",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions"
            }
          ]
        },
        {
          "product": "MR Configurator2",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Version 1.110Q",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "MT Works2",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Versions 1.156N",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "MX Component",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Version 4.20W",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "RT ToolBox3",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Versions 1.70Y",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "MELSEC iQ-R Series Motion Module",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Versions 10",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Mashav Sapir of Claroty reported this vulnerability to CISA"
        }
      ],
      "datePublic": "2020-07-30T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Multiple Mitsubishi Electric Factory Automation products have a vulnerability that allows an attacker to execute arbitrary code."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-22",
              "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-02-18T23:17:23",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://jvn.jp/vu/JVNVU90224831/"
        }
      ],
      "source": {
        "advisory": "ICSA-20-212-03",
        "discovery": "UNKNOWN"
      },
      "title": "Mitsubishi Electric Factory Automation Products Path Traversal",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2020-07-30T16:50:00.000Z",
          "ID": "CVE-2020-14523",
          "STATE": "PUBLIC",
          "TITLE": "Mitsubishi Electric Factory Automation Products Path Traversal"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "CW Configurator",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "Version 1.010L"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "FR Configurator2",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "Version 1.22Y"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "GX Works2",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "Version 1.595V"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "GX Works3",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "Version 1.063R"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "MELSOFT iQ AppPortal",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "Version 1.17T"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "MELSOFT Navigator",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "Version2.70Y"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "MI Configurator",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "All Versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "MR Configurator2",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "Version 1.110Q"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "MT Works2",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "Versions 1.156N"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "MX Component",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "Version 4.20W"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "RT ToolBox3",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "Versions 1.70Y"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "MELSEC iQ-R Series Motion Module",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "Versions 10"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Mitsubishi Electric"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Mashav Sapir of Claroty reported this vulnerability to CISA"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Multiple Mitsubishi Electric Factory Automation products have a vulnerability that allows an attacker to execute arbitrary code."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03",
              "refsource": "MISC",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03"
            },
            {
              "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf",
              "refsource": "MISC",
              "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf"
            },
            {
              "name": "https://jvn.jp/vu/JVNVU90224831/",
              "refsource": "MISC",
              "url": "https://jvn.jp/vu/JVNVU90224831/"
            }
          ]
        },
        "solution": [
          {
            "lang": "en"
          }
        ],
        "source": {
          "advisory": "ICSA-20-212-03",
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2020-14523",
    "datePublished": "2022-02-11T17:40:29.187685Z",
    "dateReserved": "2020-06-19T00:00:00",
    "dateUpdated": "2024-09-16T23:36:20.299Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-20587
Vulnerability from cvelistv5
Published
2021-02-19 19:55
Modified
2024-08-03 17:45
Severity ?
Summary
Heap-based buffer overflow vulnerability in Mitsubishi Electric FA Engineering Software (CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT SoftGOT1000 Version3 versions 3.245F and prior, GT SoftGOT2000 Version1 versions 1.250L and prior, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer versions 8.506C and prior, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer versions 1.115U and prior, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, iQ Monozukuri ANDON (Data Transfer) all versions, iQ Monozukuri Process Remote Monitoring (Data Transfer) all versions, M_CommDTM-HART all versions, M_CommDTM-IO-Link versions 1.03D and prior, MELFA-Works versions 4.4 and prior, MELSEC WinCPU Setting Utility all versions, MELSOFT EM Software Development Kit (EM Configurator) versions 1.015R and prior, MELSOFT Navigator versions 2.74C and prior, MH11 SettingTool Version2 versions 2.004E and prior, MI Configurator versions 1.004E and prior, MT Works2 versions 1.167Z and prior, MX Component versions 5.001B and prior, Network Interface Board CC IE Control utility versions 1.29F and prior, Network Interface Board CC IE Field Utility versions 1.16S and prior, Network Interface Board CC-Link Ver.2 Utility versions 1.23Z and prior, Network Interface Board MNETH utility versions 34L and prior, PX Developer versions 1.53F and prior, RT ToolBox2 versions 3.73B and prior, RT ToolBox3 versions 1.82L and prior, Setting/monitoring tools for the C Controller module (SW4PVC-CCPU) versions 4.12N and prior and SLMP Data Collector versions 1.04E and prior) allows a remote unauthenticated attacker to cause a DoS condition of the software products, and possibly to execute a malicious program on the personal computer running the software products although it has not been reproduced, by spoofing MELSEC, GOT or FREQROL and returning crafted reply packets.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T17:45:44.677Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-021_en.pdf"
          },
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://jvn.jp/vu/JVNVU92330101/index.html"
          },
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-049-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "FA Engineering Software",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "CPU Module Logging Configuration Tool versions 1.112R and prior"
            },
            {
              "status": "affected",
              "version": "CW Configurator versions 1.011M and prior"
            },
            {
              "status": "affected",
              "version": "Data Transfer versions 3.44W and prior"
            },
            {
              "status": "affected",
              "version": "EZSocket versions 5.4 and prior"
            },
            {
              "status": "affected",
              "version": "FR Configurator all versions"
            },
            {
              "status": "affected",
              "version": "FR Configurator SW3 all versions"
            },
            {
              "status": "affected",
              "version": "FR Configurator2 versions 1.24A and prior"
            },
            {
              "status": "affected",
              "version": "GT Designer3 Version1(GOT1000) versions 1.250L and prior"
            },
            {
              "status": "affected",
              "version": "GT Designer3 Version1(GOT2000) versions 1.250L and prior"
            },
            {
              "status": "affected",
              "version": "GT SoftGOT1000 Version3 versions 3.245F and prior"
            },
            {
              "status": "affected",
              "version": "GT SoftGOT2000 Version1 versions 1.250L and prior"
            },
            {
              "status": "affected",
              "version": "GX Configurator-DP versions 7.14Q and prior"
            },
            {
              "status": "affected",
              "version": "GX Configurator-QP all versions"
            },
            {
              "status": "affected",
              "version": "GX Developer versions 8.506C and prior"
            },
            {
              "status": "affected",
              "version": "GX Explorer all versions"
            },
            {
              "status": "affected",
              "version": "GX IEC Developer all versions"
            },
            {
              "status": "affected",
              "version": "GX LogViewer versions 1.115U and prior"
            },
            {
              "status": "affected",
              "version": "GX RemoteService-I all versions"
            },
            {
              "status": "affected",
              "version": "GX Works2 versions 1.597X and prior"
            },
            {
              "status": "affected",
              "version": "GX Works3 versions 1.070Y and prior"
            },
            {
              "status": "affected",
              "version": "iQ Monozukuri ANDON (Data Transfer) all versions"
            },
            {
              "status": "affected",
              "version": "iQ Monozukuri Process Remote Monitoring (Data Transfer) all versions"
            },
            {
              "status": "affected",
              "version": "M_CommDTM-HART all versions"
            },
            {
              "status": "affected",
              "version": "M_CommDTM-IO-Link versions 1.03D and prior"
            },
            {
              "status": "affected",
              "version": "MELFA-Works versions 4.4 and prior"
            },
            {
              "status": "affected",
              "version": "MELSEC WinCPU Setting Utility all versions"
            },
            {
              "status": "affected",
              "version": "MELSOFT EM Software Development Kit (EM Configurator) versions 1.015R and prior"
            },
            {
              "status": "affected",
              "version": "MELSOFT Navigator versions 2.74C and prior"
            },
            {
              "status": "affected",
              "version": "MH11 SettingTool Version2 versions 2.004E and prior"
            },
            {
              "status": "affected",
              "version": "MI Configurator versions 1.004E and prior"
            },
            {
              "status": "affected",
              "version": "MT Works2 versions 1.167Z and prior"
            },
            {
              "status": "affected",
              "version": "MX Component versions 5.001B and prior"
            },
            {
              "status": "affected",
              "version": "Network Interface Board CC IE Control utility versions 1.29F and prior"
            },
            {
              "status": "affected",
              "version": "Network Interface Board CC IE Field Utility versions 1.16S and prior"
            },
            {
              "status": "affected",
              "version": "Network Interface Board CC-Link Ver.2 Utility versions 1.23Z and prior"
            },
            {
              "status": "affected",
              "version": "Network Interface Board MNETH utility versions 34L and prior"
            },
            {
              "status": "affected",
              "version": "PX Developer versions 1.53F and prior"
            },
            {
              "status": "affected",
              "version": "RT ToolBox2 versions 3.73B and prior"
            },
            {
              "status": "affected",
              "version": "RT ToolBox3 versions 1.82L and prior"
            },
            {
              "status": "affected",
              "version": "Setting/monitoring tools for the C Controller module (SW4PVC-CCPU) versions 4.12N and prior"
            },
            {
              "status": "affected",
              "version": "SLMP Data Collector versions 1.04E and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Heap-based buffer overflow vulnerability in Mitsubishi Electric FA Engineering Software (CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT SoftGOT1000 Version3 versions 3.245F and prior, GT SoftGOT2000 Version1 versions 1.250L and prior, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer versions 8.506C and prior, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer versions 1.115U and prior, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, iQ Monozukuri ANDON (Data Transfer) all versions, iQ Monozukuri Process Remote Monitoring (Data Transfer) all versions, M_CommDTM-HART all versions, M_CommDTM-IO-Link versions 1.03D and prior, MELFA-Works versions 4.4 and prior, MELSEC WinCPU Setting Utility all versions, MELSOFT EM Software Development Kit (EM Configurator) versions 1.015R and prior, MELSOFT Navigator versions 2.74C and prior, MH11 SettingTool Version2 versions 2.004E and prior, MI Configurator versions 1.004E and prior, MT Works2 versions 1.167Z and prior, MX Component versions 5.001B and prior, Network Interface Board CC IE Control utility versions 1.29F and prior, Network Interface Board CC IE Field Utility versions 1.16S and prior, Network Interface Board CC-Link Ver.2 Utility versions 1.23Z and prior, Network Interface Board MNETH utility versions 34L and prior, PX Developer versions 1.53F and prior, RT ToolBox2 versions 3.73B and prior, RT ToolBox3 versions 1.82L and prior, Setting/monitoring tools for the C Controller module (SW4PVC-CCPU) versions 4.12N and prior and SLMP Data Collector versions 1.04E and prior) allows a remote unauthenticated attacker to cause a DoS condition of the software products, and possibly to execute a malicious program on the personal computer running the software products although it has not been reproduced, by spoofing MELSEC, GOT or FREQROL and returning crafted reply packets."
            }
          ],
          "value": "Heap-based buffer overflow vulnerability in Mitsubishi Electric FA Engineering Software (CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT SoftGOT1000 Version3 versions 3.245F and prior, GT SoftGOT2000 Version1 versions 1.250L and prior, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer versions 8.506C and prior, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer versions 1.115U and prior, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, iQ Monozukuri ANDON (Data Transfer) all versions, iQ Monozukuri Process Remote Monitoring (Data Transfer) all versions, M_CommDTM-HART all versions, M_CommDTM-IO-Link versions 1.03D and prior, MELFA-Works versions 4.4 and prior, MELSEC WinCPU Setting Utility all versions, MELSOFT EM Software Development Kit (EM Configurator) versions 1.015R and prior, MELSOFT Navigator versions 2.74C and prior, MH11 SettingTool Version2 versions 2.004E and prior, MI Configurator versions 1.004E and prior, MT Works2 versions 1.167Z and prior, MX Component versions 5.001B and prior, Network Interface Board CC IE Control utility versions 1.29F and prior, Network Interface Board CC IE Field Utility versions 1.16S and prior, Network Interface Board CC-Link Ver.2 Utility versions 1.23Z and prior, Network Interface Board MNETH utility versions 34L and prior, PX Developer versions 1.53F and prior, RT ToolBox2 versions 3.73B and prior, RT ToolBox3 versions 1.82L and prior, Setting/monitoring tools for the C Controller module (SW4PVC-CCPU) versions 4.12N and prior and SLMP Data Collector versions 1.04E and prior) allows a remote unauthenticated attacker to cause a DoS condition of the software products, and possibly to execute a malicious program on the personal computer running the software products although it has not been reproduced, by spoofing MELSEC, GOT or FREQROL and returning crafted reply packets."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Heap-based buffer overflow",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-11-18T04:19:16.037Z",
        "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "shortName": "Mitsubishi"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-021_en.pdf"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://jvn.jp/vu/JVNVU92330101/index.html"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-049-02"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
    "assignerShortName": "Mitsubishi",
    "cveId": "CVE-2021-20587",
    "datePublished": "2021-02-19T19:55:37",
    "dateReserved": "2020-12-17T00:00:00",
    "dateUpdated": "2024-08-03T17:45:44.677Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Vulnerability from fkie_nvd
Published
2022-02-11 18:15
Modified
2024-11-21 05:03
Summary
Multiple Mitsubishi Electric Factory Automation products have a vulnerability that allows an attacker to execute arbitrary code.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:cw_configurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "892E3CDC-AFC4-4EF1-AF46-3F161603DDB1",
              "versionEndIncluding": "1.010l",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:fr_configurator2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "87549502-D224-408D-8C66-41F5E8F7743A",
              "versionEndIncluding": "1.22y",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "015EB163-A5D6-4C55-8038-59823B7FF49F",
              "versionEndIncluding": "1.595v",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AE537EF6-72AE-4091-AF6E-9959C3F45632",
              "versionEndIncluding": "1.063r",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:iu_configuration_tool:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "83B09E17-9CFF-4231-AE28-FB9D99332BCB",
              "versionEndIncluding": "1.04",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:iu_developer2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D449D560-C64A-48B0-B1BB-31800FF3062E",
              "versionEndIncluding": "1.08",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:melsoft_iq_appportal:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8F2EA556-367B-4F32-99D2-C685742CCAEE",
              "versionEndIncluding": "1.17t",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:melsoft_navigator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FF88C6B0-5641-488E-9AE2-6AF479EB10BF",
              "versionEndIncluding": "2.70y",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mi_configurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A661B972-912C-4DAA-9518-CC01E0EB1A81",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mr_configurator2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "50DAB8A0-E2F3-496A-B6B6-22E4243D104C",
              "versionEndIncluding": "1.110q",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mt_works2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "04FF09A2-B1C0-4A65-A420-22A044B7F2CD",
              "versionEndIncluding": "1.156n",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mx_component:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A0C9B5B3-D4F6-4E00-89B4-964516BB989B",
              "versionEndIncluding": "4.20w",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:rt_toolbox3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "463E3740-A618-45A6-9C30-6FBC28077123",
              "versionEndIncluding": "1.70y",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:rd78g4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BEAB1838-A2E2-4D12-A216-68DD9E4624CF",
              "versionEndIncluding": "10",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:rd78g4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B9B1BA74-5B02-400C-AA98-AFB29E848299",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:rd78g8_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E213C893-9C88-42C1-BE32-634D7BB84AD6",
              "versionEndIncluding": "10",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:rd78g8:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8467C47A-2798-43FA-B132-A774B1148FC0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:rd78g16_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "389EBE60-F4CF-4E82-975D-44DCBAC74929",
              "versionEndIncluding": "10",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:rd78g16:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5F671BBC-41EE-41FF-87B1-36DBFA7A4BAD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:rd78g32_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2325BC60-32F9-46CA-8035-7E88360C15A1",
              "versionEndIncluding": "10",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:rd78g32:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "81DD3BFA-9E3A-4FAB-AB7B-6CC365628877",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:rd78g64_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DC759E3E-6D0A-4BA5-AB2E-38947331C5B2",
              "versionEndIncluding": "10",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:rd78g64:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F0A92E26-C302-4285-BED1-7B8637E252DA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:rd78ghv_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D70552B7-C943-43B0-B5BD-ED43A853657E",
              "versionEndIncluding": "10",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:rd78ghv:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "12E5533D-15A8-471B-899B-FE9F9655EE8F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:rd78ghw_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BA2C0DCD-65E6-4B93-B92F-E4FE46CCA58C",
              "versionEndIncluding": "10",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:rd78ghw:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B5C3119-7579-4623-8513-65A281BDF0D1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Multiple Mitsubishi Electric Factory Automation products have a vulnerability that allows an attacker to execute arbitrary code."
    },
    {
      "lang": "es",
      "value": "diversos productos de Mitsubishi Electric Factory Automation presentan una vulnerabilidad que permite a un atacante ejecutar c\u00f3digo arbitrario"
    }
  ],
  "id": "CVE-2020-14523",
  "lastModified": "2024-11-21T05:03:27.300",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 7.5,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.3,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.6,
        "impactScore": 6.0,
        "source": "ics-cert@hq.dhs.gov",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-02-11T18:15:08.577",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://jvn.jp/vu/JVNVU90224831/"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Patch",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://jvn.jp/vu/JVNVU90224831/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-22"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-22"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-07-02 15:15
Modified
2024-11-21 08:38
Summary
Out-of-Bounds Write vulnerability in Jungo WinDriver before 12.1.0 allows local attackers to cause a Windows blue screen error and Denial of Service (DoS).
Impacted products
Vendor Product Version
jungo windriver *
mitsubishielectric cpu_module_logging_configuration_tool *
mitsubishielectric cw_configurator *
mitsubishielectric data_transfer *
mitsubishielectric data_transfer_classic *
mitsubishielectric ezsocket *
mitsubishielectric fr_configurator_sw3 *
mitsubishielectric fr_configurator2 *
mitsubishielectric genesis64 *
mitsubishielectric gt_got1000 *
mitsubishielectric gt_got2000 *
mitsubishielectric gt_softgot1000 *
mitsubishielectric gt_softgot2000 *
mitsubishielectric gx_developer *
mitsubishielectric gx_logviewer *
mitsubishielectric gx_works2 *
mitsubishielectric gx_works3 *
mitsubishielectric iq_works *
mitsubishielectric mi_configurator *
mitsubishielectric mr_configurator *
mitsubishielectric mr_configurator2 *
mitsubishielectric mx_component *
mitsubishielectric mx_opc_server_da\/ua *
mitsubishielectric numerical_control_device_communication *
mitsubishielectric px_developer\/monitor_tool *
mitsubishielectric rt_toolbox3 *
mitsubishielectric rt_visualbox *
mitsubishielectric mrzjw3-mc2-utl_firmware *
mitsubishielectric mrzjw3-mc2-utl -
mitsubishielectric sw0dnc-mneth-b_firmware *
mitsubishielectric sw0dnc-mneth-b -
mitsubishielectric sw1dnc-ccbd2-b_firmware *
mitsubishielectric sw1dnc-ccbd2-b -
mitsubishielectric sw1dnc-ccief-j_firmware *
mitsubishielectric sw1dnc-ccief-j -
mitsubishielectric sw1dnc-ccief-b_firmware *
mitsubishielectric sw1dnc-ccief-b -
mitsubishielectric sw1dnc-mnetg-b_firmware *
mitsubishielectric sw1dnc-mnetg-b -
mitsubishielectric sw1dnc-qsccf-b_firmware *
mitsubishielectric sw1dnc-qsccf-b -
mitsubishielectric sw1dnd-emsdk-b_firmware *
mitsubishielectric sw1dnd-emsdk-b -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:jungo:windriver:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B3FD78BE-8090-4C8C-B6E3-539B78958FBD",
              "versionEndExcluding": "12.1.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:cpu_module_logging_configuration_tool:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "463EA623-0DC2-4287-A9AC-837CBDECF76C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:cw_configurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E798352C-E09B-4D18-B3A8-CFCDE0AD3675",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:data_transfer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "21CC610A-0561-46A1-9077-D01D5C3F1A8F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:data_transfer_classic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B36ABBC-DB27-44D1-B844-00DFC3BBF043",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:ezsocket:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C6E4BC24-6583-4791-9ED9-D2D675187DCD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:fr_configurator_sw3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D236ABC2-93E4-4428-B949-7E17945E4D98",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:fr_configurator2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CED78B28-BBBF-4869-BC1C-F0789867FB4C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:genesis64:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C79890F-0B41-4855-84EE-78D5896C87A1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_got1000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4400D339-BB12-414A-B891-B6105D7FCA39",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_got2000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6871A74E-8B92-4892-970F-757F404590CB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_softgot1000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "03DE7DE4-DC4B-40F3-BB22-B8E524081942",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_softgot2000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9F8037F0-C124-4EFB-AEA1-89441975D36F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_developer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9C37E74B-DA76-4E59-953E-C50D0D75804A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_logviewer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B0B195E2-6076-487C-899F-A40B886BA556",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6C4E7C31-D08D-487F-B7FF-9502783FFDB9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F4AEDEEE-5070-41E2-B4DC-6DE8456BC028",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:iq_works:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7097AFD0-5A8C-4C62-AAF7-16FB71DE210C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mi_configurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A661B972-912C-4DAA-9518-CC01E0EB1A81",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mr_configurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "76C1D9F0-48A8-4193-A781-B19ACE1B0B4B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mr_configurator2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9FB81A97-4BE8-4570-914F-304F38968613",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mx_component:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CE14782A-4AD2-4633-8A3A-D81D5C434046",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mx_opc_server_da\\/ua:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A1BABCB-EDD7-4B1D-AE49-77DD1A3CCB1C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:numerical_control_device_communication:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4F89B350-B20F-45A8-8809-E9776C319591",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:px_developer\\/monitor_tool:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2B10E09F-84F3-42E3-9B8D-DE309ED4A4B4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:rt_toolbox3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7C12A1AA-66F0-452F-9B75-562F4A979CBD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:rt_visualbox:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "33A13944-145E-453E-A409-BE4A984619AA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:mrzjw3-mc2-utl_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A10A8E35-923F-483B-A924-441B78FFCF6D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:mrzjw3-mc2-utl:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "938DDBFF-A0CC-4311-9F30-08ABDBB67742",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw0dnc-mneth-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB49716D-8E0B-4E4C-B206-104BB64F6301",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw0dnc-mneth-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C8B0237-9A91-4954-AFBE-E661467D842A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-ccbd2-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B3B0B5A-27F2-4E08-8B75-1EAAC4DC840D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-ccbd2-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0B80AF0C-EFED-4CA0-B990-0ADA6F1D0AEE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-ccief-j_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B4348FF-8691-4832-9103-F46282924299",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-ccief-j:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "07737420-567D-49CC-9A9E-555038DFF0AA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-ccief-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5D3A5D57-DB2C-429F-BB3F-8EB7F4767E1D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-ccief-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FD4CA442-BC30-407E-851E-E03037E75E8D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-mnetg-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9826969F-D449-4032-8A0B-050D7CC3B1AE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-mnetg-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "858F9CAA-E6D3-4F1D-923D-ED9E05C3AC54",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-qsccf-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "61A13AD1-22F7-4FFD-BCB7-A4FDAF2BA659",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-qsccf-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "009853DA-ACAE-4928-AE90-090A3739BD39",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnd-emsdk-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "476C7885-89D2-4A6C-94FE-E06B55A23E37",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnd-emsdk-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9DF10CF6-1C1D-4768-A349-1AEFD26F491A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Out-of-Bounds Write vulnerability in Jungo WinDriver before 12.1.0 allows local attackers to cause a Windows blue screen error and Denial of Service (DoS)."
    },
    {
      "lang": "es",
      "value": "La vulnerabilidad de escritura fuera de los l\u00edmites en Jungo WinDriver anterior a 12.1.0 permite a atacantes locales provocar un error de pantalla azul de Windows y denegaci\u00f3n de servicio (DoS)."
    }
  ],
  "id": "CVE-2023-51778",
  "lastModified": "2024-11-21T08:38:47.140",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 5.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-07-02T15:15:10.890",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Release Notes"
      ],
      "url": "https://jungo.com/windriver/versions/"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-04"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-001_en.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Release Notes"
      ],
      "url": "https://jungo.com/windriver/versions/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-04"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-001_en.pdf"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-01-30 09:15
Modified
2024-11-21 08:44
Summary
Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 and later, GT Designer3 Version1(GOT1000) all versions, GT Designer3 Version1(GOT2000) all versions, GX Works2 versions 1.11M and later, GX Works3 versions 1.106L and prior, MELSOFT Navigator versions 1.04E and later, MT Works2 all versions, MX Component versions 4.00A and later and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to bypass authentication by sending specially crafted packets and connect to the products illegally.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:ezsocket:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C6096E48-9ECD-48FF-9F5E-D182E42D41C9",
              "versionStartIncluding": "3.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:fr_configurator2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CED78B28-BBBF-4869-BC1C-F0789867FB4C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:got1000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C31EFBDE-DE71-46F3-97A1-CABC037FC31D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:got2000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5D887323-BBDD-41ED-82B8-66DE412666F5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B73766EB-FF3E-495E-B1C1-5D49A1569696",
              "versionStartIncluding": "1.11m",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F4AEDEEE-5070-41E2-B4DC-6DE8456BC028",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mc_works64:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E5790F2E-5511-46F6-94E5-F3E1A2367662",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:melsoft_navigator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5F3C096D-D510-46F4-B46A-A234CA630227",
              "versionStartIncluding": "1.04e",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mt_works2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0EC0ACF4-C303-4EC0-A755-1F9AE4152DDB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mx_component:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "407781DB-9AF9-4E3A-BF24-1787ADB33F42",
              "versionStartIncluding": "4.00a",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 and later, GT Designer3 Version1(GOT1000) all versions, GT Designer3 Version1(GOT2000) all versions, GX Works2 versions 1.11M and later, GX Works3 versions 1.106L and prior, MELSOFT Navigator versions 1.04E and later, MT Works2 all versions, MX Component versions 4.00A and later and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to bypass authentication by sending specially crafted packets and connect to the products illegally."
    },
    {
      "lang": "es",
      "value": "Autenticaci\u00f3n faltante para vulnerabilidad de funci\u00f3n cr\u00edtica en Mitsubishi Electric Corporation EZSocket versiones 3.0 y posteriores, FR Configurator2 todas las versiones, GT Designer3 Versi\u00f3n1(GOT1000) todas las versiones, GT Designer3 Versi\u00f3n1(GOT2000) todas las versiones, GX Works2 versiones 1.11M y posteriores, GX Works3 todas versiones, MELSOFT Navigator versiones 1.04E y posteriores, MT Works2 todas las versiones, MX Component versiones 4.00A y posteriores y MX OPC Server DA/UA todas las versiones permiten a un atacante remoto no autenticado eludir la autenticaci\u00f3n enviando paquetes especialmente manipulados y conect\u00e1ndose a los productos ilegalmente."
    }
  ],
  "id": "CVE-2023-6942",
  "lastModified": "2024-11-21T08:44:53.183",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-01-30T09:15:47.757",
  "references": [
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://jvn.jp/vu/JVNVU95103362"
    },
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-030-02"
    },
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-020_en.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://jvn.jp/vu/JVNVU95103362"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-030-02"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-020_en.pdf"
    }
  ],
  "sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-306"
        }
      ],
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-11-25 00:15
Modified
2024-11-21 06:59
Summary
Cleartext Storage of Sensitive Information in Memory vulnerability in Mitsubishi Electric Corporation GX Works3 versions 1.015R and later, GX Works2 all versions and GX Developer versions 8.40S and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users could obtain information about the project file for MELSEC safety CPU modules or project file for MELSEC Q/FX/L series with security setting.
Impacted products



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "56BD062B-0D41-42E2-B9EF-B7FBB514CFF9",
              "versionEndIncluding": "1.086q",
              "versionStartIncluding": "1.015r",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C7C6A654-1B83-4743-8DDE-B8C5AA5C4D2A",
              "versionStartIncluding": "1.087r",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Cleartext Storage of Sensitive Information in Memory vulnerability in Mitsubishi Electric Corporation GX Works3 versions 1.015R and later, GX Works2 all versions and GX Developer versions 8.40S and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users could obtain information about the project file for MELSEC safety CPU modules or project file for MELSEC Q/FX/L series with security setting."
    },
    {
      "lang": "es",
      "value": "Vulnerabilidad de almacenamiento de texto sin cifrar de informaci\u00f3n confidencial en memoria en Mitsubishi Electric Corporation GX Works3 versiones 1.015R y posteriores, GX Works2 todas las versiones y GX Developer versiones 8.40S y posteriores permite que un atacante remoto no autenticado revele informaci\u00f3n sensible. Como resultado, los usuarios no autenticados podr\u00edan obtener informaci\u00f3n sobre el archivo de proyecto para los m\u00f3dulos de CPU de seguridad de MELSEC o el archivo de proyecto para la serie MELSEC Q/FX/L con configuraci\u00f3n de seguridad."
    }
  ],
  "id": "CVE-2022-29832",
  "lastModified": "2024-11-21T06:59:46.563",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 3.7,
          "baseSeverity": "LOW",
          "confidentialityImpact": "LOW",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.2,
        "impactScore": 1.4,
        "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-11-25T00:15:10.507",
  "references": [
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://jvn.jp/vu/JVNVU97244961"
    },
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"
    },
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://jvn.jp/vu/JVNVU97244961"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
    }
  ],
  "sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-316"
        }
      ],
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-312"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2020-06-30 11:15
Modified
2024-11-21 05:34
Summary
Uncontrolled resource consumption vulnerability in Mitsubishi Electoric FA Engineering Software (CPU Module Logging Configuration Tool Ver. 1.94Y and earlier, CW Configurator Ver. 1.010L and earlier, EM Software Development Kit (EM Configurator) Ver. 1.010L and earlier, GT Designer3 (GOT2000) Ver. 1.221F and earlier, GX LogViewer Ver. 1.96A and earlier, GX Works2 Ver. 1.586L and earlier, GX Works3 Ver. 1.058L and earlier, M_CommDTM-HART Ver. 1.00A, M_CommDTM-IO-Link Ver. 1.02C and earlier, MELFA-Works Ver. 4.3 and earlier, MELSEC-L Flexible High-Speed I/O Control Module Configuration Tool Ver.1.004E and earlier, MELSOFT FieldDeviceConfigurator Ver. 1.03D and earlier, MELSOFT iQ AppPortal Ver. 1.11M and earlier, MELSOFT Navigator Ver. 2.58L and earlier, MI Configurator Ver. 1.003D and earlier, Motion Control Setting Ver. 1.005F and earlier, MR Configurator2 Ver. 1.72A and earlier, MT Works2 Ver. 1.156N and earlier, RT ToolBox2 Ver. 3.72A and earlier, and RT ToolBox3 Ver. 1.50C and earlier) allows an attacker to cause a denial of service (DoS) condition attacks via unspecified vectors.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:cpu_module_logging_configuration_tool:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5AA4BCF9-CE1B-4A53-BBBD-396FE7D8D410",
              "versionEndIncluding": "1.94y",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:cw_configurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "892E3CDC-AFC4-4EF1-AF46-3F161603DDB1",
              "versionEndIncluding": "1.010l",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:em_configurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD8B6AFD-17BE-4657-9F55-B0CA52E2578A",
              "versionEndIncluding": "1.010l",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_designer3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "567CE406-0FCE-44DC-B210-1E54EDB6FE11",
              "versionEndIncluding": "1.221f",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_logviewer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "591B76E1-665F-4473-8A65-B8549B61807F",
              "versionEndIncluding": "1.100e",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7CCB1E6D-333D-458E-AE2D-974E16195811",
              "versionEndIncluding": "1.590q",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "20F14A8B-E42D-4621-8BCC-A6D28A8A0D7A",
              "versionEndIncluding": "1.060n",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:m_commdtm-hart:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "35D76E9B-394E-47A1-B6F1-4854909A8D59",
              "versionEndIncluding": "1.01b",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:m_commdtm-io-link:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "37B4823F-E257-4CFF-A20B-FAB4A60D49D9",
              "versionEndIncluding": "1.03d",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:melfa-works:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4116C452-19C3-4F48-8A05-864BD884BDD0",
              "versionEndIncluding": "4.4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:melsec-l_flexible_high-speed_i\\/o_control_module_configuration_tool:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BB41FBDD-2785-4012-AB84-2B1F947E9512",
              "versionEndIncluding": "1.005f",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:melsoft_fielddeviceconfigurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6DBBC676-19E1-4780-8D23-6888884E67A4",
              "versionEndIncluding": "1.04e",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:melsoft_iq_appportal:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "56B1A257-F1C6-4213-92A0-7476E3EB6207",
              "versionEndIncluding": "1.14q",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:melsoft_navigator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "76A6CCE9-ACB8-4A24-A4E5-0F8DCBC4475B",
              "versionEndIncluding": "2.62q",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mi_configurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DA012067-3CF9-46E8-9C5D-C64D92C2574D",
              "versionEndIncluding": "1.004e",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:motion_control_setting:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "19CEBFB8-E23E-4ABB-9337-221D6749D456",
              "versionEndIncluding": "1.006g",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mr_configurator2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6998E84B-0EFC-4ACB-BFC6-FFC1A675F1B3",
              "versionEndIncluding": "1.100e",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mt_works2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0303271B-F016-4D0E-A862-313A31B8CD60",
              "versionEndIncluding": "1.160s",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:rt_toolbox2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5BD4EC4A-ACF7-45F2-893D-569B4F8F8909",
              "versionEndIncluding": "3.73b",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:rt_toolbox3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5E66C5F1-23BF-42F9-8A25-FE8A7E66B07D",
              "versionEndIncluding": "1.60n",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Uncontrolled resource consumption vulnerability in Mitsubishi Electoric FA Engineering Software (CPU Module Logging Configuration Tool Ver. 1.94Y and earlier, CW Configurator Ver. 1.010L and earlier, EM Software Development Kit (EM Configurator) Ver. 1.010L and earlier, GT Designer3 (GOT2000) Ver. 1.221F and earlier, GX LogViewer Ver. 1.96A and earlier, GX Works2 Ver. 1.586L and earlier, GX Works3 Ver. 1.058L and earlier, M_CommDTM-HART Ver. 1.00A, M_CommDTM-IO-Link Ver. 1.02C and earlier, MELFA-Works Ver. 4.3 and earlier, MELSEC-L Flexible High-Speed I/O Control Module Configuration Tool Ver.1.004E and earlier, MELSOFT FieldDeviceConfigurator Ver. 1.03D and earlier, MELSOFT iQ AppPortal Ver. 1.11M and earlier, MELSOFT Navigator Ver. 2.58L and earlier, MI Configurator Ver. 1.003D and earlier, Motion Control Setting Ver. 1.005F and earlier, MR Configurator2 Ver. 1.72A and earlier, MT Works2 Ver. 1.156N and earlier, RT ToolBox2 Ver. 3.72A and earlier, and RT ToolBox3 Ver. 1.50C and earlier) allows an attacker to cause a denial of service (DoS) condition attacks via unspecified vectors."
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad de consumo de recursos no controlado en Mitsubishi Electoric FA Engineering Software (CPU Module Logging Configuration Tool Versiones 1.94Y y anteriores, CW Configurator Versiones 1.010L y anteriores, EM Software Development Kit (EM Configurator) Versiones 1.010L y anteriores, GT Designer3 (GOT2000) Versiones 1.221F y anteriores, GX LogViewer Versiones 1.96A y anteriores, GX Works2 Versiones 1.586L y anteriores, GX Works3 Versiones 1.058L y anteriores, M_CommDTM-HART Versiones 1.00A, M_CommDTM-IO-Link Versiones 1.02C y anteriores, MELFA-Works Versiones 4.3 y anteriores, MELSEC-L Flexible High-Speed I/O Control Module Configuration Tool Versiones 1.004E y anteriores, MELSOFT FieldDeviceConfigurator Versiones 1.03D y anteriores, MELSOFT iQ AppPortal Versiones 1.11M y anteriores, MELSOFT Navigator Versiones 2.58L y anteriores, MI Configurator Versiones 1.003D y anteriores, Motion Control Setting Versiones 1.005F y anteriores, MR Configurator2 Versiones 1.72A y anteriores, MT Works2 Versiones 1.156N y anteriores , RT ToolBox2 Versiones 3.72A y anteriores, y RT ToolBox3 Versiones 1.50C y anteriores, permite a un atacante causar ataques de condici\u00f3n de denegaci\u00f3n de servicio (DoS) por medio de vectores no especificados"
    }
  ],
  "id": "CVE-2020-5603",
  "lastModified": "2024-11-21T05:34:20.803",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 5.0,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2020-06-30T11:15:11.397",
  "references": [
    {
      "source": "vultures@jpcert.or.jp",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://jvn.jp/en/vu/JVNVU90307594/index.html"
    },
    {
      "source": "vultures@jpcert.or.jp",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-004_en.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://jvn.jp/en/vu/JVNVU90307594/index.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-004_en.pdf"
    }
  ],
  "sourceIdentifier": "vultures@jpcert.or.jp",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-400"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-11-25 00:15
Modified
2024-11-21 06:59
Summary
Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Motion Control Setting(GX Works3 related software) versions from 1.000A and later allows a remote unauthenticated attacker to disclose or tamper with sensitive information. As a result, unauthenticated attackers may obtain information about project files illegally.
Impacted products



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A868567B-2BAA-45AE-AEC9-3AFEF2361297",
              "versionEndIncluding": "1.011m",
              "versionStartIncluding": "1.000a",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "56BD062B-0D41-42E2-B9EF-B7FBB514CFF9",
              "versionEndIncluding": "1.086q",
              "versionStartIncluding": "1.015r",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C7C6A654-1B83-4743-8DDE-B8C5AA5C4D2A",
              "versionStartIncluding": "1.087r",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Motion Control Setting(GX Works3 related software) versions from 1.000A and later allows a remote unauthenticated attacker to disclose or tamper with sensitive information. As a result, unauthenticated attackers may obtain information about project files illegally."
    },
    {
      "lang": "es",
      "value": "El uso de una vulnerabilidad de clave criptogr\u00e1fica codificada en Mitsubishi Electric GX Works3 en las versiones 1.000A hasta 1.095Z y la configuraci\u00f3n de control de movimiento (software relacionado con GX Works3) de 1.000A y posteriores permite a un atacante remoto no autenticado revelar o alterar informaci\u00f3n sensible. Como resultado, los atacantes no autenticados pueden obtener informaci\u00f3n sobre archivos de proyecto de forma ilegal."
    }
  ],
  "id": "CVE-2022-29830",
  "lastModified": "2024-11-21T06:59:46.313",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 9.1,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.2,
        "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 9.1,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.2,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-11-25T00:15:10.367",
  "references": [
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://jvn.jp/vu/JVNVU97244961/index.html"
    },
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"
    },
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://jvn.jp/vu/JVNVU97244961/index.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
    }
  ],
  "sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-321"
        }
      ],
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-798"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-11-25 00:15
Modified
2024-11-21 06:59
Summary
Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers may view programs and project file or execute programs illegally.
Impacted products



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A868567B-2BAA-45AE-AEC9-3AFEF2361297",
              "versionEndIncluding": "1.011m",
              "versionStartIncluding": "1.000a",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "56BD062B-0D41-42E2-B9EF-B7FBB514CFF9",
              "versionEndIncluding": "1.086q",
              "versionStartIncluding": "1.015r",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C7C6A654-1B83-4743-8DDE-B8C5AA5C4D2A",
              "versionStartIncluding": "1.087r",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers may view programs and project file or execute programs illegally."
    },
    {
      "lang": "es",
      "value": "El uso de una vulnerabilidad de clave criptogr\u00e1fica codificada en las versiones 1.000A y posteriores de Mitsubishi Electric GX Works3 permite que un atacante remoto no autenticado revele informaci\u00f3n sensible. Como resultado, los atacantes no autenticados pueden ver programas y archivos de proyectos o ejecutar programas ilegalmente."
    }
  ],
  "id": "CVE-2022-29828",
  "lastModified": "2024-11-21T06:59:46.053",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 6.8,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.2,
        "impactScore": 4.0,
        "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-11-25T00:15:10.230",
  "references": [
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://jvn.jp/vu/JVNVU97244961/index.html"
    },
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"
    },
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://jvn.jp/vu/JVNVU97244961/index.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
    }
  ],
  "sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-321"
        }
      ],
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-798"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2023-11-30 04:15
Modified
2024-11-21 08:41
Summary
Malicious Code Execution Vulnerability due to External Control of File Name or Path in multiple Mitsubishi Electric FA Engineering Software Products allows a malicious attacker to execute a malicious code by having legitimate users open a specially crafted project file, which could result in information disclosure, tampering and deletion, or a denial-of-service (DoS) condition.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F4AEDEEE-5070-41E2-B4DC-6DE8456BC028",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:melsoft_iq_appportal:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FDE16619-E980-45D1-BF56-C46E920CBD3D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:melsoft_navigator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "89ACB781-BD3B-4BA2-B036-D6D95FB3AC05",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:motion_control_setting:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4FDBCE52-4251-437A-B614-76E6F0B4A2AD",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Malicious Code Execution Vulnerability due to External Control of File Name or Path in multiple Mitsubishi Electric FA Engineering Software Products allows a malicious attacker to execute a malicious code by having legitimate users open a specially crafted project file, which could result in information disclosure, tampering and deletion, or a denial-of-service (DoS) condition."
    },
    {
      "lang": "es",
      "value": "La vulnerabilidad de ejecuci\u00f3n de c\u00f3digo malicioso debido al control externo del nombre o ruta del archivo en m\u00faltiples productos de software de ingenier\u00eda de Mitsubishi Electric FA permite a un atacante malicioso ejecutar un c\u00f3digo malicioso haciendo que usuarios leg\u00edtimos abran un archivo de proyecto especialmente manipulado, lo que podr\u00eda resultar en la divulgaci\u00f3n de informaci\u00f3n, la manipulaci\u00f3n y eliminaci\u00f3n o una condici\u00f3n de Denegaci\u00f3n de Servicio (DoS)."
    }
  ],
  "id": "CVE-2023-5247",
  "lastModified": "2024-11-21T08:41:22.180",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-11-30T04:15:07.867",
  "references": [
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "tags": [
        "Mitigation",
        "Third Party Advisory"
      ],
      "url": "https://jvn.jp/vu/JVNVU93383160/"
    },
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-016_en.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mitigation",
        "Third Party Advisory"
      ],
      "url": "https://jvn.jp/vu/JVNVU93383160/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-016_en.pdf"
    }
  ],
  "sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-73"
        }
      ],
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-610"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-02-19 20:15
Modified
2024-11-21 05:46
Severity ?
Summary
Improper handling of length parameter inconsistency vulnerability in Mitsubishi Electric FA Engineering Software(CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT SoftGOT1000 Version3 versions 3.245F and prior, GT SoftGOT2000 Version1 versions 1.250L and prior, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer versions 8.506C and prior, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer versions 1.115U and prior, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, iQ Monozukuri ANDON (Data Transfer) all versions, iQ Monozukuri Process Remote Monitoring (Data Transfer) all versions, M_CommDTM-HART all versions, M_CommDTM-IO-Link versions 1.03D and prior, MELFA-Works versions 4.4 and prior, MELSEC WinCPU Setting Utility all versions, MELSOFT EM Software Development Kit (EM Configurator) versions 1.015R and prior, MELSOFT Navigator versions 2.74C and prior, MH11 SettingTool Version2 versions 2.004E and prior, MI Configurator versions 1.004E and prior, MT Works2 versions 1.167Z and prior, MX Component versions 5.001B and prior, Network Interface Board CC IE Control utility versions 1.29F and prior, Network Interface Board CC IE Field Utility versions 1.16S and prior, Network Interface Board CC-Link Ver.2 Utility versions 1.23Z and prior, Network Interface Board MNETH utility versions 34L and prior, PX Developer versions 1.53F and prior, RT ToolBox2 versions 3.73B and prior, RT ToolBox3 versions 1.82L and prior, Setting/monitoring tools for the C Controller module (SW4PVC-CCPU) versions 4.12N and prior and SLMP Data Collector versions 1.04E and prior) allows a remote unauthenticated attacker to cause a DoS condition of the software products, and possibly to execute a malicious program on the personal computer running the software products although it has not been reproduced, by spoofing MELSEC, GOT or FREQROL and returning crafted reply packets.
Impacted products
Vendor Product Version
mitsubishielectric c_controller_module_setting_and_monitoring_tool *
mitsubishielectric cpu_module_logging_configuration_tool *
mitsubishielectric cw_configurator *
mitsubishielectric data_transfer *
mitsubishielectric ezsocket *
mitsubishielectric fr_configurator *
mitsubishielectric fr_configurator_sw3 *
mitsubishielectric fr_configurator2 *
mitsubishielectric gt_designer3 *
mitsubishielectric gt_softgot1000 *
mitsubishielectric gt_softgot2000 *
mitsubishielectric gx_configurator-dp *
mitsubishielectric gx_configurator-qp *
mitsubishielectric gx_developer *
mitsubishielectric gx_explorer *
mitsubishielectric gx_iec_developer *
mitsubishielectric gx_logviewer *
mitsubishielectric gx_remoteservice-i *
mitsubishielectric gx_works2 *
mitsubishielectric gx_works3 *
mitsubishielectric iq_monozukuri_andon -
mitsubishielectric iq_monozukuri_process_remote_monitoring -
mitsubishielectric m_commdtm-hart *
mitsubishielectric m_commdtm-io-link *
mitsubishielectric melfa-works *
mitsubishielectric melsec_wincpu_setting_utility *
mitsubishielectric melsoft_em_software_development_kit *
mitsubishielectric melsoft_navigator *
mitsubishielectric mh11_settingtool_version2 *
mitsubishielectric mi_configurator *
mitsubishielectric mt_works2 *
mitsubishielectric mx_component *
mitsubishielectric network_interface_board_cc-link *
mitsubishielectric network_interface_board_cc_ie_control_utility *
mitsubishielectric network_interface_board_cc_ie_field_utility *
mitsubishielectric network_interface_board_mneth_utility *
mitsubishielectric px_developer *
mitsubishielectric rt_toolbox2 *
mitsubishielectric rt_toolbox3 *
mitsubishielectric setting\/monitoring_tools_for_the_c_controller_module *
mitsubishielectric slmp_data_collector *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:c_controller_module_setting_and_monitoring_tool:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4DB4A4DA-DBC0-42A8-B933-933DE45F004D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:cpu_module_logging_configuration_tool:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D83BA6D0-2A25-4DDA-B7BA-DE11FA55D276",
              "versionEndIncluding": "1.112r",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:cw_configurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "91D2BDFB-0A0A-4A1B-8671-8B5D652253DE",
              "versionEndIncluding": "1.011m",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:data_transfer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6AF9A2A7-6F9E-4CA9-8485-3AF83A6411DD",
              "versionEndIncluding": "3.44w",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:ezsocket:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C6E4BC24-6583-4791-9ED9-D2D675187DCD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:fr_configurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1773F87D-7E58-4E00-90B7-92BDDB4AA3BF",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:fr_configurator_sw3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D236ABC2-93E4-4428-B949-7E17945E4D98",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:fr_configurator2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "18E81D47-F88A-481B-98E0-56C52CDF6C8B",
              "versionEndIncluding": "1.24a",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_designer3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "66DEB37E-A837-4A2F-9660-7DE8441004D7",
              "versionEndIncluding": "1.250l",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_softgot1000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B835ECE8-6923-47DF-9BB8-E0AA8D77228D",
              "versionEndIncluding": "3.245f",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_softgot2000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "92C96AF0-1DCE-4769-AAC4-422F8B411A2A",
              "versionEndIncluding": "1.250l",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_configurator-dp:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E767C69A-23D9-4C67-AA66-392D5E70ED7B",
              "versionEndIncluding": "7.14q",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_configurator-qp:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "492299CE-FE94-4CB4-9D62-03F05CBCDE74",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_developer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C4588898-2ABA-4AA3-A33F-551387DC84AC",
              "versionEndIncluding": "8.506c",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_explorer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "18A18533-FF83-4C7C-839D-077A7523DBDC",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_iec_developer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "974700B4-FC0B-4097-8826-CE055E13434F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_logviewer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6FFEE46E-C37D-4E82-BDC5-1225C03BFFFE",
              "versionEndIncluding": "1.115u",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_remoteservice-i:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C4DAEEF5-50CA-4DCD-8B1A-BAE8DEEA23AA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "76E34DC3-5D48-49DB-B1CB-CB5BDDED169D",
              "versionEndIncluding": "1.597x",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "920FC6C1-32FA-4251-81AA-B76D353B216A",
              "versionEndIncluding": "1.070y",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:iq_monozukuri_andon:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "07756207-64DF-4F89-B3A1-19086CCC42BB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:iq_monozukuri_process_remote_monitoring:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "978160CD-B7D4-4494-A5BB-CA0195441985",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:m_commdtm-hart:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EBC92717-C371-42B4-8AA6-73E14B60A87E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:m_commdtm-io-link:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "87B55AB8-B00D-4960-9F31-45E1855B109E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:melfa-works:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4116C452-19C3-4F48-8A05-864BD884BDD0",
              "versionEndIncluding": "4.4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:melsec_wincpu_setting_utility:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C51CF8E-49C1-418C-B410-50B23F9A23D7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:melsoft_em_software_development_kit:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "724C0E0B-5658-4040-A925-A07128EAD323",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:melsoft_navigator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0DC7353B-EFF7-432D-8F88-0D5EBBBBE4C0",
              "versionEndIncluding": "2.74c",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mh11_settingtool_version2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A8D3CBAF-5876-4DCE-908F-CCA8B0DDDB75",
              "versionEndIncluding": "2.004e",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mi_configurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A661B972-912C-4DAA-9518-CC01E0EB1A81",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mt_works2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "57031F64-353E-403C-B7F8-0A145E70CBE7",
              "versionEndIncluding": "1.167z",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mx_component:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3B623A09-688E-49B1-99EF-CFA8DADC79E8",
              "versionEndIncluding": "5.001b",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:network_interface_board_cc-link:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "87A92A26-7148-4A2A-BAFA-5F819468F48E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:network_interface_board_cc_ie_control_utility:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4D02C00E-B8C6-4987-8F25-E3D46FEDB44A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:network_interface_board_cc_ie_field_utility:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "07F71BF3-FC69-4DA3-9989-DA269B557085",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:network_interface_board_mneth_utility:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "171CD9BC-2A02-4ACA-B29C-332094AA3EDA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:px_developer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "445EF081-A7BB-4568-850F-00CF58060D62",
              "versionEndIncluding": "1.53f",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:rt_toolbox2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5BD4EC4A-ACF7-45F2-893D-569B4F8F8909",
              "versionEndIncluding": "3.73b",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:rt_toolbox3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "779B0C13-D3DD-4D27-B18B-C0119B7BC5CB",
              "versionEndIncluding": "1.82l",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:setting\\/monitoring_tools_for_the_c_controller_module:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "85CBC7FE-6EF9-4DA5-8128-849233A8DC72",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:slmp_data_collector:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8814A8BA-AA54-4270-AAB1-679D0881D715",
              "versionEndIncluding": "1.04e",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Improper handling of length parameter inconsistency vulnerability in Mitsubishi Electric FA Engineering Software(CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT SoftGOT1000 Version3 versions 3.245F and prior, GT SoftGOT2000 Version1 versions 1.250L and prior, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer versions 8.506C and prior, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer versions 1.115U and prior, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, iQ Monozukuri ANDON (Data Transfer) all versions, iQ Monozukuri Process Remote Monitoring (Data Transfer) all versions, M_CommDTM-HART all versions, M_CommDTM-IO-Link versions 1.03D and prior, MELFA-Works versions 4.4 and prior, MELSEC WinCPU Setting Utility all versions, MELSOFT EM Software Development Kit (EM Configurator) versions 1.015R and prior, MELSOFT Navigator versions 2.74C and prior, MH11 SettingTool Version2 versions 2.004E and prior, MI Configurator versions 1.004E and prior, MT Works2 versions 1.167Z and prior, MX Component versions 5.001B and prior, Network Interface Board CC IE Control utility versions 1.29F and prior, Network Interface Board CC IE Field Utility versions 1.16S and prior, Network Interface Board CC-Link Ver.2 Utility versions 1.23Z and prior, Network Interface Board MNETH utility versions 34L and prior, PX Developer versions 1.53F and prior, RT ToolBox2 versions 3.73B and prior, RT ToolBox3 versions 1.82L and prior, Setting/monitoring tools for the C Controller module (SW4PVC-CCPU) versions 4.12N and prior and SLMP Data Collector versions 1.04E and prior) allows a remote unauthenticated attacker to cause a DoS condition of the software products, and possibly to execute a malicious program on the personal computer running the software products although it has not been reproduced, by spoofing MELSEC, GOT or FREQROL and returning crafted reply packets."
    },
    {
      "lang": "es",
      "value": "Manejo inadecuado de la vulnerabilidad de inconsistencia de par\u00e1metros de longitud en el software de ingenier\u00eda FA de Mitsubishi Electric (Herramienta de configuraci\u00f3n de registro del m\u00f3dulo de la CPU versiones 1.112R y anteriores, Configurador CW versiones 1.011M y anteriores, Transferencia de datos versiones 3.44W y anteriores, EZSocket versiones 5.4 y anteriores, Configurador FR todas las versiones, Configurador FR SW3 todas las versiones, Configurador FR2 versiones 1. 24A y anteriores, GT Designer3 Versi\u00f3n1(GOT1000) versiones 1.250L y anteriores, GT Designer3 Versi\u00f3n1(GOT2000) versiones 1.250L y anteriores, GT SoftGOT1000 Versi\u00f3n3 versiones 3.245F y anteriores, GT SoftGOT2000 Versi\u00f3n1 versiones 1.250L y anteriores, GX Configurator-DP versiones 7.14Q y anteriores, GX Configurator-QP todas las versiones, GX Developer versiones 8.506C y anteriores, GX Explorer todas las versiones, GX IEC Developer todas las versiones, GX LogViewer versiones 1. 115U y anteriores, GX RemoteService-I todas las versiones, GX Works2 versiones 1.597X y anteriores, GX Works3 versiones 1.070Y y anteriores, iQ Monozukuri ANDON (Data Transfer) todas las versiones, iQ Monozukuri Process Remote Monitoring (Data Transfer) todas las versiones, M_CommDTM-HART todas las versiones, M_CommDTM-IO-Link versiones 1. 03D y anteriores, MELFA-Works versiones 4.4 y anteriores, MELSEC WinCPU Setting Utility todas las versiones, MELSOFT EM Software Development Kit (EM Configurator) versiones 1. 015R y anteriores, MELSOFT Navigator versiones 2.74C y anteriores, MH11 SettingTool Version2 versiones 2.004E y anteriores, MI Configurator versiones 1.004E y anteriores, MT Works2 versiones 1.167Z y anteriores, MX Component versiones 5.001B y anteriores, Network Interface Board CC IE Control utility versiones 1.29F y anteriores, Network Interface Board CC IE Field Utility versiones 1.16S y anteriores, Network Interface Board CC-Link Ver.2 1.23Z y anteriores, Network Interface Board MNETH utility versions 34L y anteriores, PX Developer versions 1.53F y anteriores, RT ToolBox2 versions 3.73B y anteriores, RT ToolBox3 versions 1.82L y anteriores, Setting/monitoring tools for the C Controller module (SW4PVC-CCPU) versions 4.12N y anteriores y SLMP Data Collector versions 1. 04E y anteriores) permite que un atacante remoto no autenticado provoque una condici\u00f3n de denegaci\u00f3n de servicio de los productos de software, y posiblemente ejecute un programa malicioso en el ordenador personal que ejecuta los productos de software, aunque no se ha reproducido, mediante la suplantaci\u00f3n de MELSEC, GOT o FREQROL y el retorno de paquetes de respuesta manipulados"
    }
  ],
  "id": "CVE-2021-20588",
  "lastModified": "2024-11-21T05:46:49.790",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 7.5,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-02-19T20:15:13.023",
  "references": [
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://jvn.jp/vu/JVNVU92330101/index.html"
    },
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-049-02"
    },
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-021_en.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://jvn.jp/vu/JVNVU92330101/index.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-049-02"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-021_en.pdf"
    }
  ],
  "sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2023-09-20 03:15
Modified
2024-11-21 08:34
Summary
Incorrect Default Permissions vulnerability in Mitsubishi Electric Corporation multiple FA engineering software products allows a malicious local attacker to execute a malicious code, resulting in information disclosure, tampering with and deletion, or a denial-of-service (DoS) condition, if the product is installed in a folder other than the default installation folder.
Impacted products
Vendor Product Version
mitsubishielectric gx_works3 *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F4AEDEEE-5070-41E2-B4DC-6DE8456BC028",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Incorrect Default Permissions vulnerability in Mitsubishi Electric Corporation multiple FA engineering software products allows a malicious local attacker to execute a malicious code, resulting in information disclosure, tampering with and deletion, or a denial-of-service (DoS) condition, if the product is installed in a folder other than the default installation folder."
    },
    {
      "lang": "es",
      "value": "Vulnerabilidad de Permisos Predeterminados Incorrectos debido a una soluci\u00f3n incompleta para abordar CVE-2020-14496 en los productos de software de ingenier\u00eda de Mitsubishi Electric Corporation FA permite que un atacante local malicioso ejecute un c\u00f3digo malicioso, lo que podr\u00eda resultar en la divulgaci\u00f3n, manipulaci\u00f3n y eliminaci\u00f3n de informaci\u00f3n, o una condici\u00f3n de denegaci\u00f3n fuera de servicio (DoS). Sin embargo, si la versi\u00f3n mitigada descrita en el aviso para CVE-2020-14496 se utiliza y se instala en la carpeta de instalaci\u00f3n predeterminada, esta vulnerabilidad no afecta a los productos."
    }
  ],
  "id": "CVE-2023-4088",
  "lastModified": "2024-11-21T08:34:21.840",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 9.3,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.5,
        "impactScore": 6.0,
        "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-09-20T03:15:13.687",
  "references": [
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "url": "https://jvn.jp/vu/JVNVU96447193/index.html"
    },
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-269-03"
    },
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-010_en.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://jvn.jp/vu/JVNVU96447193/index.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-269-03"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-010_en.pdf"
    }
  ],
  "sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-276"
        }
      ],
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-276"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-07-02 15:15
Modified
2024-11-21 08:55
Summary
Out-of-Bounds Write vulnerability in Jungo WinDriver before 12.6.0 allows local attackers to cause a Windows blue screen error and Denial of Service (DoS).
Impacted products
Vendor Product Version
jungo windriver *
mitsubishielectric cpu_module_logging_configuration_tool *
mitsubishielectric cw_configurator *
mitsubishielectric data_transfer *
mitsubishielectric data_transfer_classic *
mitsubishielectric ezsocket *
mitsubishielectric fr_configurator_sw3 *
mitsubishielectric fr_configurator2 *
mitsubishielectric genesis64 *
mitsubishielectric gt_got1000 *
mitsubishielectric gt_got2000 *
mitsubishielectric gt_softgot1000 *
mitsubishielectric gt_softgot2000 *
mitsubishielectric gx_developer *
mitsubishielectric gx_logviewer *
mitsubishielectric gx_works2 *
mitsubishielectric gx_works3 *
mitsubishielectric iq_works *
mitsubishielectric mi_configurator *
mitsubishielectric mr_configurator *
mitsubishielectric mr_configurator2 *
mitsubishielectric mx_component *
mitsubishielectric mx_opc_server_da\/ua *
mitsubishielectric numerical_control_device_communication *
mitsubishielectric px_developer\/monitor_tool *
mitsubishielectric rt_toolbox3 *
mitsubishielectric rt_visualbox *
mitsubishielectric mrzjw3-mc2-utl_firmware *
mitsubishielectric mrzjw3-mc2-utl -
mitsubishielectric sw0dnc-mneth-b_firmware *
mitsubishielectric sw0dnc-mneth-b -
mitsubishielectric sw1dnc-ccbd2-b_firmware *
mitsubishielectric sw1dnc-ccbd2-b -
mitsubishielectric sw1dnc-ccief-j_firmware *
mitsubishielectric sw1dnc-ccief-j -
mitsubishielectric sw1dnc-ccief-b_firmware *
mitsubishielectric sw1dnc-ccief-b -
mitsubishielectric sw1dnc-mnetg-b_firmware *
mitsubishielectric sw1dnc-mnetg-b -
mitsubishielectric sw1dnc-qsccf-b_firmware *
mitsubishielectric sw1dnc-qsccf-b -
mitsubishielectric sw1dnd-emsdk-b_firmware *
mitsubishielectric sw1dnd-emsdk-b -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:jungo:windriver:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "14DB96B1-125F-4E91-AB5A-A3A32627B0F2",
              "versionEndExcluding": "12.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:cpu_module_logging_configuration_tool:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "463EA623-0DC2-4287-A9AC-837CBDECF76C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:cw_configurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E798352C-E09B-4D18-B3A8-CFCDE0AD3675",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:data_transfer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "21CC610A-0561-46A1-9077-D01D5C3F1A8F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:data_transfer_classic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B36ABBC-DB27-44D1-B844-00DFC3BBF043",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:ezsocket:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C6E4BC24-6583-4791-9ED9-D2D675187DCD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:fr_configurator_sw3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D236ABC2-93E4-4428-B949-7E17945E4D98",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:fr_configurator2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CED78B28-BBBF-4869-BC1C-F0789867FB4C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:genesis64:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C79890F-0B41-4855-84EE-78D5896C87A1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_got1000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4400D339-BB12-414A-B891-B6105D7FCA39",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_got2000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6871A74E-8B92-4892-970F-757F404590CB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_softgot1000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "03DE7DE4-DC4B-40F3-BB22-B8E524081942",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_softgot2000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9F8037F0-C124-4EFB-AEA1-89441975D36F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_developer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9C37E74B-DA76-4E59-953E-C50D0D75804A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_logviewer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B0B195E2-6076-487C-899F-A40B886BA556",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6C4E7C31-D08D-487F-B7FF-9502783FFDB9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F4AEDEEE-5070-41E2-B4DC-6DE8456BC028",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:iq_works:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7097AFD0-5A8C-4C62-AAF7-16FB71DE210C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mi_configurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A661B972-912C-4DAA-9518-CC01E0EB1A81",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mr_configurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "76C1D9F0-48A8-4193-A781-B19ACE1B0B4B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mr_configurator2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9FB81A97-4BE8-4570-914F-304F38968613",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mx_component:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CE14782A-4AD2-4633-8A3A-D81D5C434046",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mx_opc_server_da\\/ua:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A1BABCB-EDD7-4B1D-AE49-77DD1A3CCB1C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:numerical_control_device_communication:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4F89B350-B20F-45A8-8809-E9776C319591",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:px_developer\\/monitor_tool:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2B10E09F-84F3-42E3-9B8D-DE309ED4A4B4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:rt_toolbox3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7C12A1AA-66F0-452F-9B75-562F4A979CBD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:rt_visualbox:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "33A13944-145E-453E-A409-BE4A984619AA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:mrzjw3-mc2-utl_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A10A8E35-923F-483B-A924-441B78FFCF6D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:mrzjw3-mc2-utl:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "938DDBFF-A0CC-4311-9F30-08ABDBB67742",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw0dnc-mneth-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB49716D-8E0B-4E4C-B206-104BB64F6301",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw0dnc-mneth-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C8B0237-9A91-4954-AFBE-E661467D842A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-ccbd2-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B3B0B5A-27F2-4E08-8B75-1EAAC4DC840D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-ccbd2-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0B80AF0C-EFED-4CA0-B990-0ADA6F1D0AEE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-ccief-j_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B4348FF-8691-4832-9103-F46282924299",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-ccief-j:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "07737420-567D-49CC-9A9E-555038DFF0AA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-ccief-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5D3A5D57-DB2C-429F-BB3F-8EB7F4767E1D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-ccief-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FD4CA442-BC30-407E-851E-E03037E75E8D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-mnetg-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9826969F-D449-4032-8A0B-050D7CC3B1AE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-mnetg-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "858F9CAA-E6D3-4F1D-923D-ED9E05C3AC54",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-qsccf-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "61A13AD1-22F7-4FFD-BCB7-A4FDAF2BA659",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-qsccf-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "009853DA-ACAE-4928-AE90-090A3739BD39",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnd-emsdk-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "476C7885-89D2-4A6C-94FE-E06B55A23E37",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnd-emsdk-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9DF10CF6-1C1D-4768-A349-1AEFD26F491A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Out-of-Bounds Write vulnerability in Jungo WinDriver before 12.6.0 allows local attackers to cause a Windows blue screen error and Denial of Service (DoS)."
    },
    {
      "lang": "es",
      "value": "La vulnerabilidad de escritura fuera de los l\u00edmites en Jungo WinDriver anterior a 12.6.0 permite a atacantes locales provocar un error de pantalla azul de Windows y denegaci\u00f3n de servicio (DoS)."
    }
  ],
  "id": "CVE-2024-22103",
  "lastModified": "2024-11-21T08:55:35.383",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 5.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 4.4,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 0.8,
        "impactScore": 3.6,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-07-02T15:15:11.150",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Release Notes"
      ],
      "url": "https://jungo.com/windriver/versions/"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-04"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-001_en.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Release Notes"
      ],
      "url": "https://jungo.com/windriver/versions/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-04"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-001_en.pdf"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-05-19 18:15
Modified
2024-11-21 05:03
Summary
Successful exploitation of this vulnerability for multiple Mitsubishi Electric Factory Automation Engineering Software Products of various versions could allow an attacker to escalate privilege and execute malicious programs, which could cause a denial-of-service condition, and allow information to be disclosed, tampered with, and/or destroyed.
References



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:cpu_module_logging_configuration_tool:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "69A02BE6-633A-4A94-890C-586B3A42E19F",
              "versionEndExcluding": "1.106k",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:cw_configurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "60875630-C0F2-434E-8D11-51B44F62CBA5",
              "versionEndExcluding": "1.011m",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:data_transfer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE83331F-B795-410A-8510-351945025444",
              "versionEndExcluding": "3.41t",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:em_configurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A0A01F0C-0B10-4906-9389-4D53AE3CD7FD",
              "versionEndExcluding": "1.015r",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:ezsocket:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A9FFEA10-20FA-4B73-ACA5-AB7462820123",
              "versionEndExcluding": "4.6",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:fr_configurator2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2877EB49-8A69-426B-B7EB-87DEF3975562",
              "versionEndExcluding": "1.23z",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_designer3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C3393020-A6E6-431A-B572-E28948F6A970",
              "versionEndExcluding": "1.236w",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_softgot1000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3DC963D1-281A-48DE-B822-5254643C98E7",
              "versionEndExcluding": "3.245f",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_softgot2000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "20E2D739-F982-4ED4-ADFB-505777CF9888",
              "versionEndExcluding": "1.236w",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_logviewer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0809A627-EEC8-475E-997F-E3FAE2C39261",
              "versionEndExcluding": "1.106k",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F2B0AC1-1BEC-4D79-9995-527E3A770A66",
              "versionEndExcluding": "1.595v",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "80BF474D-E018-4612-93FD-F3A661C13A6D",
              "versionEndExcluding": "1.065t",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:m_commdtm-hart:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9C9ECB87-B07E-4E52-BF3F-8AD4AA03826B",
              "versionEndExcluding": "1.01b",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:m_commdtm-io-link:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "50FA8FAD-3DF4-453C-A55C-5F622DD76460",
              "versionEndExcluding": "1.04e",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:melfa-works:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "ED888C84-4CD8-464A-A3A0-F623EB0F4920",
              "versionEndExcluding": "4.4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:melsoft_fielddeviceconfigurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE1E2976-38B4-4B1B-AC01-B3D8C26A1BB2",
              "versionEndExcluding": "1.04e",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:melsoft_navigator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "01D32795-831A-43D6-9F90-82A67F5E9081",
              "versionEndExcluding": "2.70y",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mh11_settingtool_version2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7A6DE218-D030-4DDF-B504-B176DFE7662A",
              "versionEndExcluding": "2.003d",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:motorizer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0FD24F8E-869B-413A-9BF1-555CF827F3C9",
              "versionEndExcluding": "1.010l",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mr_configurator2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "470498DC-4A30-4EC2-B9C7-B5348D2F1381",
              "versionEndExcluding": "1.106l",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mt_works2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7926DBE1-335C-40E2-AD74-AE89DC9A0095",
              "versionEndExcluding": "1.160s",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mx_component:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DCBBBA97-3C41-423F-8534-098070E49A97",
              "versionEndExcluding": "4.20w",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:network_interface_board_cc-link_ver.2_utility:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3CFA2E01-1D66-40D6-8575-0E216376CC25",
              "versionEndExcluding": "1.24a",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:network_interface_board_cc_ie_control_utility:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EBC15323-7468-4688-A9C2-01208B4849A4",
              "versionEndExcluding": "1.30g",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:network_interface_board_cc_ie_field_utility:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F605A144-5A10-44C9-94DC-3B0D66E39431",
              "versionEndExcluding": "1.17t",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:network_interface_board_mneth_utility:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "54DBB417-5543-4AEB-9467-6197868C8C18",
              "versionEndExcluding": "35m",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:px_developer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9987641F-1BD4-445A-86E4-778CFFFFEBD2",
              "versionEndExcluding": "1.53f",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:rt_toolbox2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A11F999D-CE97-49B6-9AF3-DD32D0E0779F",
              "versionEndExcluding": "3.73b",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:rt_toolbox3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B03CE992-45F6-48EA-BE86-0041F0CDBEF7",
              "versionEndExcluding": "1.80j",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Successful exploitation of this vulnerability for multiple Mitsubishi Electric Factory Automation Engineering Software Products of various versions could allow an attacker to escalate privilege and execute malicious programs, which could cause a denial-of-service condition, and allow information to be disclosed, tampered with, and/or destroyed."
    },
    {
      "lang": "es",
      "value": "Una explotaci\u00f3n con \u00e9xito de esta vulnerabilidad para m\u00faltiples Productos Mitsubishi Electric Factory Automation Engineering Software de varias versiones podr\u00eda permitir a un atacante escalar privilegios y ejecutar programas maliciosos, lo que podr\u00eda causar una condici\u00f3n de denegaci\u00f3n de servicio, y permitir que la informaci\u00f3n sea divulgada, manipulada y/o destruida"
    }
  ],
  "id": "CVE-2020-14496",
  "lastModified": "2024-11-21T05:03:23.697",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 7.5,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.3,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.6,
        "impactScore": 6.0,
        "source": "ics-cert@hq.dhs.gov",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-05-19T18:15:08.360",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-02"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-02"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-275"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-07-02 16:15
Modified
2024-11-21 08:55
Summary
Improper privilege management in Jungo WinDriver before 12.5.1 allows local attackers to escalate privileges, execute arbitrary code, or cause a Denial of Service (DoS).
Impacted products
Vendor Product Version
jungo windriver *
mitsubishielectric cpu_module_logging_configuration_tool *
mitsubishielectric cw_configurator *
mitsubishielectric data_transfer *
mitsubishielectric data_transfer_classic *
mitsubishielectric ezsocket *
mitsubishielectric fr_configurator_sw3 *
mitsubishielectric fr_configurator2 *
mitsubishielectric genesis64 *
mitsubishielectric gt_got1000 *
mitsubishielectric gt_got2000 *
mitsubishielectric gt_softgot1000 *
mitsubishielectric gt_softgot2000 *
mitsubishielectric gx_developer *
mitsubishielectric gx_logviewer *
mitsubishielectric gx_works2 *
mitsubishielectric gx_works3 *
mitsubishielectric iq_works *
mitsubishielectric mi_configurator *
mitsubishielectric mr_configurator *
mitsubishielectric mr_configurator2 *
mitsubishielectric mx_component *
mitsubishielectric mx_opc_server_da\/ua *
mitsubishielectric numerical_control_device_communication *
mitsubishielectric px_developer\/monitor_tool *
mitsubishielectric rt_toolbox3 *
mitsubishielectric rt_visualbox *
mitsubishielectric mrzjw3-mc2-utl_firmware *
mitsubishielectric mrzjw3-mc2-utl -
mitsubishielectric sw0dnc-mneth-b_firmware *
mitsubishielectric sw0dnc-mneth-b -
mitsubishielectric sw1dnc-ccbd2-b_firmware *
mitsubishielectric sw1dnc-ccbd2-b -
mitsubishielectric sw1dnc-ccief-j_firmware *
mitsubishielectric sw1dnc-ccief-j -
mitsubishielectric sw1dnc-ccief-b_firmware *
mitsubishielectric sw1dnc-ccief-b -
mitsubishielectric sw1dnc-mnetg-b_firmware *
mitsubishielectric sw1dnc-mnetg-b -
mitsubishielectric sw1dnc-qsccf-b_firmware *
mitsubishielectric sw1dnc-qsccf-b -
mitsubishielectric sw1dnd-emsdk-b_firmware *
mitsubishielectric sw1dnd-emsdk-b -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:jungo:windriver:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CD5769FE-170B-4FCC-9A2E-B487C2DAFB16",
              "versionEndExcluding": "12.5.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:cpu_module_logging_configuration_tool:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "463EA623-0DC2-4287-A9AC-837CBDECF76C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:cw_configurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E798352C-E09B-4D18-B3A8-CFCDE0AD3675",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:data_transfer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "21CC610A-0561-46A1-9077-D01D5C3F1A8F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:data_transfer_classic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B36ABBC-DB27-44D1-B844-00DFC3BBF043",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:ezsocket:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C6E4BC24-6583-4791-9ED9-D2D675187DCD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:fr_configurator_sw3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D236ABC2-93E4-4428-B949-7E17945E4D98",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:fr_configurator2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CED78B28-BBBF-4869-BC1C-F0789867FB4C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:genesis64:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C79890F-0B41-4855-84EE-78D5896C87A1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_got1000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4400D339-BB12-414A-B891-B6105D7FCA39",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_got2000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6871A74E-8B92-4892-970F-757F404590CB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_softgot1000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "03DE7DE4-DC4B-40F3-BB22-B8E524081942",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_softgot2000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9F8037F0-C124-4EFB-AEA1-89441975D36F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_developer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9C37E74B-DA76-4E59-953E-C50D0D75804A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_logviewer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B0B195E2-6076-487C-899F-A40B886BA556",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6C4E7C31-D08D-487F-B7FF-9502783FFDB9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F4AEDEEE-5070-41E2-B4DC-6DE8456BC028",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:iq_works:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7097AFD0-5A8C-4C62-AAF7-16FB71DE210C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mi_configurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A661B972-912C-4DAA-9518-CC01E0EB1A81",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mr_configurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "76C1D9F0-48A8-4193-A781-B19ACE1B0B4B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mr_configurator2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9FB81A97-4BE8-4570-914F-304F38968613",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mx_component:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CE14782A-4AD2-4633-8A3A-D81D5C434046",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mx_opc_server_da\\/ua:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A1BABCB-EDD7-4B1D-AE49-77DD1A3CCB1C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:numerical_control_device_communication:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4F89B350-B20F-45A8-8809-E9776C319591",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:px_developer\\/monitor_tool:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2B10E09F-84F3-42E3-9B8D-DE309ED4A4B4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:rt_toolbox3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7C12A1AA-66F0-452F-9B75-562F4A979CBD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:rt_visualbox:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "33A13944-145E-453E-A409-BE4A984619AA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:mrzjw3-mc2-utl_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A10A8E35-923F-483B-A924-441B78FFCF6D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:mrzjw3-mc2-utl:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "938DDBFF-A0CC-4311-9F30-08ABDBB67742",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw0dnc-mneth-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB49716D-8E0B-4E4C-B206-104BB64F6301",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw0dnc-mneth-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C8B0237-9A91-4954-AFBE-E661467D842A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-ccbd2-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B3B0B5A-27F2-4E08-8B75-1EAAC4DC840D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-ccbd2-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0B80AF0C-EFED-4CA0-B990-0ADA6F1D0AEE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-ccief-j_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B4348FF-8691-4832-9103-F46282924299",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-ccief-j:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "07737420-567D-49CC-9A9E-555038DFF0AA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-ccief-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5D3A5D57-DB2C-429F-BB3F-8EB7F4767E1D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-ccief-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FD4CA442-BC30-407E-851E-E03037E75E8D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-mnetg-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9826969F-D449-4032-8A0B-050D7CC3B1AE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-mnetg-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "858F9CAA-E6D3-4F1D-923D-ED9E05C3AC54",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-qsccf-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "61A13AD1-22F7-4FFD-BCB7-A4FDAF2BA659",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-qsccf-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "009853DA-ACAE-4928-AE90-090A3739BD39",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnd-emsdk-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "476C7885-89D2-4A6C-94FE-E06B55A23E37",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnd-emsdk-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9DF10CF6-1C1D-4768-A349-1AEFD26F491A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Improper privilege management in Jungo WinDriver before 12.5.1 allows local attackers to escalate privileges, execute arbitrary code, or cause a Denial of Service (DoS)."
    },
    {
      "lang": "es",
      "value": "La gesti\u00f3n inadecuada de privilegios en Jungo WinDriver anterior a 12.5.1 permite a atacantes locales escalar privilegios, ejecutar c\u00f3digo arbitrario o provocar una denegaci\u00f3n de servicio (DoS)."
    }
  ],
  "id": "CVE-2024-22106",
  "lastModified": "2024-11-21T08:55:36.177",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.0,
        "impactScore": 6.0,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-07-02T16:15:03.980",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Release Notes"
      ],
      "url": "https://jungo.com/windriver/versions/"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-04"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-001_en.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Release Notes"
      ],
      "url": "https://jungo.com/windriver/versions/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-04"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-001_en.pdf"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-269"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-07-02 16:15
Modified
2024-11-21 09:00
Summary
Denial of Service (DoS) vulnerability in Jungo WinDriver before 12.7.0 allows local attackers to cause a Windows blue screen error.
Impacted products
Vendor Product Version
jungo windriver *
mitsubishielectric cpu_module_logging_configuration_tool *
mitsubishielectric cw_configurator *
mitsubishielectric data_transfer *
mitsubishielectric data_transfer_classic *
mitsubishielectric ezsocket *
mitsubishielectric fr_configurator_sw3 *
mitsubishielectric fr_configurator2 *
mitsubishielectric genesis64 *
mitsubishielectric gt_got1000 *
mitsubishielectric gt_got2000 *
mitsubishielectric gt_softgot1000 *
mitsubishielectric gt_softgot2000 *
mitsubishielectric gx_developer *
mitsubishielectric gx_logviewer *
mitsubishielectric gx_works2 *
mitsubishielectric gx_works3 *
mitsubishielectric iq_works *
mitsubishielectric mi_configurator *
mitsubishielectric mr_configurator *
mitsubishielectric mr_configurator2 *
mitsubishielectric mx_component *
mitsubishielectric mx_opc_server_da\/ua *
mitsubishielectric numerical_control_device_communication *
mitsubishielectric px_developer\/monitor_tool *
mitsubishielectric rt_toolbox3 *
mitsubishielectric rt_visualbox *
mitsubishielectric mrzjw3-mc2-utl_firmware *
mitsubishielectric mrzjw3-mc2-utl -
mitsubishielectric sw0dnc-mneth-b_firmware *
mitsubishielectric sw0dnc-mneth-b -
mitsubishielectric sw1dnc-ccbd2-b_firmware *
mitsubishielectric sw1dnc-ccbd2-b -
mitsubishielectric sw1dnc-ccief-j_firmware *
mitsubishielectric sw1dnc-ccief-j -
mitsubishielectric sw1dnc-ccief-b_firmware *
mitsubishielectric sw1dnc-ccief-b -
mitsubishielectric sw1dnc-mnetg-b_firmware *
mitsubishielectric sw1dnc-mnetg-b -
mitsubishielectric sw1dnc-qsccf-b_firmware *
mitsubishielectric sw1dnc-qsccf-b -
mitsubishielectric sw1dnd-emsdk-b_firmware *
mitsubishielectric sw1dnd-emsdk-b -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:jungo:windriver:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D1AD3035-A0C1-47C1-BBEB-10D8A93E8EC5",
              "versionEndExcluding": "12.7.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:cpu_module_logging_configuration_tool:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "463EA623-0DC2-4287-A9AC-837CBDECF76C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:cw_configurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E798352C-E09B-4D18-B3A8-CFCDE0AD3675",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:data_transfer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "21CC610A-0561-46A1-9077-D01D5C3F1A8F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:data_transfer_classic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B36ABBC-DB27-44D1-B844-00DFC3BBF043",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:ezsocket:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C6E4BC24-6583-4791-9ED9-D2D675187DCD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:fr_configurator_sw3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D236ABC2-93E4-4428-B949-7E17945E4D98",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:fr_configurator2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CED78B28-BBBF-4869-BC1C-F0789867FB4C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:genesis64:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C79890F-0B41-4855-84EE-78D5896C87A1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_got1000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4400D339-BB12-414A-B891-B6105D7FCA39",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_got2000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6871A74E-8B92-4892-970F-757F404590CB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_softgot1000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "03DE7DE4-DC4B-40F3-BB22-B8E524081942",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_softgot2000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9F8037F0-C124-4EFB-AEA1-89441975D36F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_developer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9C37E74B-DA76-4E59-953E-C50D0D75804A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_logviewer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B0B195E2-6076-487C-899F-A40B886BA556",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6C4E7C31-D08D-487F-B7FF-9502783FFDB9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F4AEDEEE-5070-41E2-B4DC-6DE8456BC028",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:iq_works:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7097AFD0-5A8C-4C62-AAF7-16FB71DE210C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mi_configurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A661B972-912C-4DAA-9518-CC01E0EB1A81",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mr_configurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "76C1D9F0-48A8-4193-A781-B19ACE1B0B4B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mr_configurator2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9FB81A97-4BE8-4570-914F-304F38968613",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mx_component:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CE14782A-4AD2-4633-8A3A-D81D5C434046",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mx_opc_server_da\\/ua:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A1BABCB-EDD7-4B1D-AE49-77DD1A3CCB1C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:numerical_control_device_communication:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4F89B350-B20F-45A8-8809-E9776C319591",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:px_developer\\/monitor_tool:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2B10E09F-84F3-42E3-9B8D-DE309ED4A4B4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:rt_toolbox3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7C12A1AA-66F0-452F-9B75-562F4A979CBD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:rt_visualbox:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "33A13944-145E-453E-A409-BE4A984619AA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:mrzjw3-mc2-utl_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A10A8E35-923F-483B-A924-441B78FFCF6D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:mrzjw3-mc2-utl:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "938DDBFF-A0CC-4311-9F30-08ABDBB67742",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw0dnc-mneth-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB49716D-8E0B-4E4C-B206-104BB64F6301",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw0dnc-mneth-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C8B0237-9A91-4954-AFBE-E661467D842A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-ccbd2-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B3B0B5A-27F2-4E08-8B75-1EAAC4DC840D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-ccbd2-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0B80AF0C-EFED-4CA0-B990-0ADA6F1D0AEE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-ccief-j_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B4348FF-8691-4832-9103-F46282924299",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-ccief-j:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "07737420-567D-49CC-9A9E-555038DFF0AA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-ccief-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5D3A5D57-DB2C-429F-BB3F-8EB7F4767E1D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-ccief-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FD4CA442-BC30-407E-851E-E03037E75E8D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-mnetg-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9826969F-D449-4032-8A0B-050D7CC3B1AE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-mnetg-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "858F9CAA-E6D3-4F1D-923D-ED9E05C3AC54",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-qsccf-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "61A13AD1-22F7-4FFD-BCB7-A4FDAF2BA659",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-qsccf-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "009853DA-ACAE-4928-AE90-090A3739BD39",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnd-emsdk-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "476C7885-89D2-4A6C-94FE-E06B55A23E37",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnd-emsdk-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9DF10CF6-1C1D-4768-A349-1AEFD26F491A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Denial of Service (DoS) vulnerability in Jungo WinDriver before 12.7.0 allows local attackers to cause a Windows blue screen error."
    },
    {
      "lang": "es",
      "value": "Vulnerabilidad de denegaci\u00f3n de servicio (DoS) en Jungo WinDriver anterior a 12.7.0 permite a atacantes locales provocar un error de pantalla azul de Windows."
    }
  ],
  "id": "CVE-2024-25087",
  "lastModified": "2024-11-21T09:00:13.447",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 5.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-07-02T16:15:04.157",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Release Notes"
      ],
      "url": "https://jungo.com/windriver/versions/"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-04"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-001_en.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Release Notes"
      ],
      "url": "https://jungo.com/windriver/versions/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-04"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-001_en.pdf"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-404"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-07-02 15:15
Modified
2024-11-21 08:38
Summary
Improper privilege management in Jungo WinDriver before 12.1.0 allows local attackers to escalate privileges and execute arbitrary code.
Impacted products
Vendor Product Version
jungo windriver *
mitsubishielectric cpu_module_logging_configuration_tool *
mitsubishielectric cw_configurator *
mitsubishielectric data_transfer *
mitsubishielectric data_transfer_classic *
mitsubishielectric ezsocket *
mitsubishielectric fr_configurator_sw3 *
mitsubishielectric fr_configurator2 *
mitsubishielectric genesis64 *
mitsubishielectric gt_got1000 *
mitsubishielectric gt_got2000 *
mitsubishielectric gt_softgot1000 *
mitsubishielectric gt_softgot2000 *
mitsubishielectric gx_developer *
mitsubishielectric gx_logviewer *
mitsubishielectric gx_works2 *
mitsubishielectric gx_works3 *
mitsubishielectric iq_works *
mitsubishielectric mi_configurator *
mitsubishielectric mr_configurator *
mitsubishielectric mr_configurator2 *
mitsubishielectric mx_component *
mitsubishielectric mx_opc_server_da\/ua *
mitsubishielectric numerical_control_device_communication *
mitsubishielectric px_developer\/monitor_tool *
mitsubishielectric rt_toolbox3 *
mitsubishielectric rt_visualbox *
mitsubishielectric mrzjw3-mc2-utl_firmware *
mitsubishielectric mrzjw3-mc2-utl -
mitsubishielectric sw0dnc-mneth-b_firmware *
mitsubishielectric sw0dnc-mneth-b -
mitsubishielectric sw1dnc-ccbd2-b_firmware *
mitsubishielectric sw1dnc-ccbd2-b -
mitsubishielectric sw1dnc-ccief-j_firmware *
mitsubishielectric sw1dnc-ccief-j -
mitsubishielectric sw1dnc-ccief-b_firmware *
mitsubishielectric sw1dnc-ccief-b -
mitsubishielectric sw1dnc-mnetg-b_firmware *
mitsubishielectric sw1dnc-mnetg-b -
mitsubishielectric sw1dnc-qsccf-b_firmware *
mitsubishielectric sw1dnc-qsccf-b -
mitsubishielectric sw1dnd-emsdk-b_firmware *
mitsubishielectric sw1dnd-emsdk-b -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:jungo:windriver:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B3FD78BE-8090-4C8C-B6E3-539B78958FBD",
              "versionEndExcluding": "12.1.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:cpu_module_logging_configuration_tool:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "463EA623-0DC2-4287-A9AC-837CBDECF76C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:cw_configurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E798352C-E09B-4D18-B3A8-CFCDE0AD3675",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:data_transfer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "21CC610A-0561-46A1-9077-D01D5C3F1A8F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:data_transfer_classic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B36ABBC-DB27-44D1-B844-00DFC3BBF043",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:ezsocket:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C6E4BC24-6583-4791-9ED9-D2D675187DCD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:fr_configurator_sw3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D236ABC2-93E4-4428-B949-7E17945E4D98",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:fr_configurator2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CED78B28-BBBF-4869-BC1C-F0789867FB4C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:genesis64:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C79890F-0B41-4855-84EE-78D5896C87A1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_got1000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4400D339-BB12-414A-B891-B6105D7FCA39",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_got2000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6871A74E-8B92-4892-970F-757F404590CB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_softgot1000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "03DE7DE4-DC4B-40F3-BB22-B8E524081942",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_softgot2000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9F8037F0-C124-4EFB-AEA1-89441975D36F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_developer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9C37E74B-DA76-4E59-953E-C50D0D75804A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_logviewer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B0B195E2-6076-487C-899F-A40B886BA556",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6C4E7C31-D08D-487F-B7FF-9502783FFDB9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F4AEDEEE-5070-41E2-B4DC-6DE8456BC028",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:iq_works:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7097AFD0-5A8C-4C62-AAF7-16FB71DE210C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mi_configurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A661B972-912C-4DAA-9518-CC01E0EB1A81",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mr_configurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "76C1D9F0-48A8-4193-A781-B19ACE1B0B4B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mr_configurator2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9FB81A97-4BE8-4570-914F-304F38968613",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mx_component:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CE14782A-4AD2-4633-8A3A-D81D5C434046",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mx_opc_server_da\\/ua:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A1BABCB-EDD7-4B1D-AE49-77DD1A3CCB1C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:numerical_control_device_communication:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4F89B350-B20F-45A8-8809-E9776C319591",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:px_developer\\/monitor_tool:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2B10E09F-84F3-42E3-9B8D-DE309ED4A4B4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:rt_toolbox3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7C12A1AA-66F0-452F-9B75-562F4A979CBD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:rt_visualbox:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "33A13944-145E-453E-A409-BE4A984619AA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:mrzjw3-mc2-utl_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A10A8E35-923F-483B-A924-441B78FFCF6D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:mrzjw3-mc2-utl:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "938DDBFF-A0CC-4311-9F30-08ABDBB67742",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw0dnc-mneth-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB49716D-8E0B-4E4C-B206-104BB64F6301",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw0dnc-mneth-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C8B0237-9A91-4954-AFBE-E661467D842A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-ccbd2-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B3B0B5A-27F2-4E08-8B75-1EAAC4DC840D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-ccbd2-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0B80AF0C-EFED-4CA0-B990-0ADA6F1D0AEE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-ccief-j_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B4348FF-8691-4832-9103-F46282924299",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-ccief-j:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "07737420-567D-49CC-9A9E-555038DFF0AA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-ccief-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5D3A5D57-DB2C-429F-BB3F-8EB7F4767E1D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-ccief-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FD4CA442-BC30-407E-851E-E03037E75E8D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-mnetg-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9826969F-D449-4032-8A0B-050D7CC3B1AE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-mnetg-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "858F9CAA-E6D3-4F1D-923D-ED9E05C3AC54",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-qsccf-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "61A13AD1-22F7-4FFD-BCB7-A4FDAF2BA659",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-qsccf-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "009853DA-ACAE-4928-AE90-090A3739BD39",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnd-emsdk-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "476C7885-89D2-4A6C-94FE-E06B55A23E37",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnd-emsdk-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9DF10CF6-1C1D-4768-A349-1AEFD26F491A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Improper privilege management in Jungo WinDriver before 12.1.0 allows local attackers to escalate privileges and execute arbitrary code."
    },
    {
      "lang": "es",
      "value": "La gesti\u00f3n inadecuada de privilegios en Jungo WinDriver anterior a 12.1.0 permite a atacantes locales escalar privilegios y ejecutar c\u00f3digo arbitrario."
    }
  ],
  "id": "CVE-2023-51776",
  "lastModified": "2024-11-21T08:38:46.690",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-07-02T15:15:10.663",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Release Notes"
      ],
      "url": "https://jungo.com/windriver/versions/"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-04"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-001_en.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Release Notes"
      ],
      "url": "https://jungo.com/windriver/versions/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-04"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-001_en.pdf"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-07-02 15:15
Modified
2024-11-21 08:55
Summary
Denial of Service (DoS) vulnerability in Jungo WinDriver before 12.6.0 allows local attackers to cause a Windows blue screen error.
Impacted products
Vendor Product Version
jungo windriver *
mitsubishielectric cpu_module_logging_configuration_tool *
mitsubishielectric cw_configurator *
mitsubishielectric data_transfer *
mitsubishielectric data_transfer_classic *
mitsubishielectric ezsocket *
mitsubishielectric fr_configurator_sw3 *
mitsubishielectric fr_configurator2 *
mitsubishielectric genesis64 *
mitsubishielectric gt_got1000 *
mitsubishielectric gt_got2000 *
mitsubishielectric gt_softgot1000 *
mitsubishielectric gt_softgot2000 *
mitsubishielectric gx_developer *
mitsubishielectric gx_logviewer *
mitsubishielectric gx_works2 *
mitsubishielectric gx_works3 *
mitsubishielectric iq_works *
mitsubishielectric mi_configurator *
mitsubishielectric mr_configurator *
mitsubishielectric mr_configurator2 *
mitsubishielectric mx_component *
mitsubishielectric mx_opc_server_da\/ua *
mitsubishielectric numerical_control_device_communication *
mitsubishielectric px_developer\/monitor_tool *
mitsubishielectric rt_toolbox3 *
mitsubishielectric rt_visualbox *
mitsubishielectric mrzjw3-mc2-utl_firmware *
mitsubishielectric mrzjw3-mc2-utl -
mitsubishielectric sw0dnc-mneth-b_firmware *
mitsubishielectric sw0dnc-mneth-b -
mitsubishielectric sw1dnc-ccbd2-b_firmware *
mitsubishielectric sw1dnc-ccbd2-b -
mitsubishielectric sw1dnc-ccief-j_firmware *
mitsubishielectric sw1dnc-ccief-j -
mitsubishielectric sw1dnc-ccief-b_firmware *
mitsubishielectric sw1dnc-ccief-b -
mitsubishielectric sw1dnc-mnetg-b_firmware *
mitsubishielectric sw1dnc-mnetg-b -
mitsubishielectric sw1dnc-qsccf-b_firmware *
mitsubishielectric sw1dnc-qsccf-b -
mitsubishielectric sw1dnd-emsdk-b_firmware *
mitsubishielectric sw1dnd-emsdk-b -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:jungo:windriver:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "14DB96B1-125F-4E91-AB5A-A3A32627B0F2",
              "versionEndExcluding": "12.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:cpu_module_logging_configuration_tool:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "463EA623-0DC2-4287-A9AC-837CBDECF76C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:cw_configurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E798352C-E09B-4D18-B3A8-CFCDE0AD3675",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:data_transfer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "21CC610A-0561-46A1-9077-D01D5C3F1A8F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:data_transfer_classic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B36ABBC-DB27-44D1-B844-00DFC3BBF043",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:ezsocket:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C6E4BC24-6583-4791-9ED9-D2D675187DCD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:fr_configurator_sw3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D236ABC2-93E4-4428-B949-7E17945E4D98",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:fr_configurator2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CED78B28-BBBF-4869-BC1C-F0789867FB4C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:genesis64:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C79890F-0B41-4855-84EE-78D5896C87A1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_got1000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4400D339-BB12-414A-B891-B6105D7FCA39",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_got2000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6871A74E-8B92-4892-970F-757F404590CB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_softgot1000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "03DE7DE4-DC4B-40F3-BB22-B8E524081942",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_softgot2000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9F8037F0-C124-4EFB-AEA1-89441975D36F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_developer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9C37E74B-DA76-4E59-953E-C50D0D75804A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_logviewer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B0B195E2-6076-487C-899F-A40B886BA556",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6C4E7C31-D08D-487F-B7FF-9502783FFDB9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F4AEDEEE-5070-41E2-B4DC-6DE8456BC028",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:iq_works:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7097AFD0-5A8C-4C62-AAF7-16FB71DE210C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mi_configurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A661B972-912C-4DAA-9518-CC01E0EB1A81",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mr_configurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "76C1D9F0-48A8-4193-A781-B19ACE1B0B4B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mr_configurator2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9FB81A97-4BE8-4570-914F-304F38968613",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mx_component:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CE14782A-4AD2-4633-8A3A-D81D5C434046",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mx_opc_server_da\\/ua:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A1BABCB-EDD7-4B1D-AE49-77DD1A3CCB1C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:numerical_control_device_communication:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4F89B350-B20F-45A8-8809-E9776C319591",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:px_developer\\/monitor_tool:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2B10E09F-84F3-42E3-9B8D-DE309ED4A4B4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:rt_toolbox3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7C12A1AA-66F0-452F-9B75-562F4A979CBD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:rt_visualbox:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "33A13944-145E-453E-A409-BE4A984619AA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:mrzjw3-mc2-utl_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A10A8E35-923F-483B-A924-441B78FFCF6D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:mrzjw3-mc2-utl:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "938DDBFF-A0CC-4311-9F30-08ABDBB67742",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw0dnc-mneth-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB49716D-8E0B-4E4C-B206-104BB64F6301",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw0dnc-mneth-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C8B0237-9A91-4954-AFBE-E661467D842A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-ccbd2-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B3B0B5A-27F2-4E08-8B75-1EAAC4DC840D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-ccbd2-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0B80AF0C-EFED-4CA0-B990-0ADA6F1D0AEE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-ccief-j_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B4348FF-8691-4832-9103-F46282924299",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-ccief-j:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "07737420-567D-49CC-9A9E-555038DFF0AA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-ccief-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5D3A5D57-DB2C-429F-BB3F-8EB7F4767E1D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-ccief-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FD4CA442-BC30-407E-851E-E03037E75E8D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-mnetg-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9826969F-D449-4032-8A0B-050D7CC3B1AE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-mnetg-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "858F9CAA-E6D3-4F1D-923D-ED9E05C3AC54",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-qsccf-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "61A13AD1-22F7-4FFD-BCB7-A4FDAF2BA659",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-qsccf-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "009853DA-ACAE-4928-AE90-090A3739BD39",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnd-emsdk-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "476C7885-89D2-4A6C-94FE-E06B55A23E37",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnd-emsdk-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9DF10CF6-1C1D-4768-A349-1AEFD26F491A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Denial of Service (DoS) vulnerability in Jungo WinDriver before 12.6.0 allows local attackers to cause a Windows blue screen error."
    },
    {
      "lang": "es",
      "value": "Vulnerabilidad de denegaci\u00f3n de servicio (DoS) en Jungo WinDriver anterior a 12.6.0 permite a atacantes locales provocar un error de pantalla azul de Windows."
    }
  ],
  "id": "CVE-2024-22102",
  "lastModified": "2024-11-21T08:55:35.143",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 5.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-07-02T15:15:11.070",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Release Notes"
      ],
      "url": "https://jungo.com/windriver/versions/"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-04"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-001_en.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Release Notes"
      ],
      "url": "https://jungo.com/windriver/versions/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-04"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-001_en.pdf"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-07-02 16:15
Modified
2024-11-21 09:02
Summary
Improper privilege management in Jungo WinDriver 6.0.0 through 16.1.0 allows local attackers to escalate privileges and execute arbitrary code.
Impacted products
Vendor Product Version
jungo windriver *
mitsubishielectric cpu_module_logging_configuration_tool *
mitsubishielectric cw_configurator *
mitsubishielectric data_transfer *
mitsubishielectric data_transfer_classic *
mitsubishielectric ezsocket *
mitsubishielectric fr_configurator_sw3 *
mitsubishielectric fr_configurator2 *
mitsubishielectric genesis64 *
mitsubishielectric gt_got1000 *
mitsubishielectric gt_got2000 *
mitsubishielectric gt_softgot1000 *
mitsubishielectric gt_softgot2000 *
mitsubishielectric gx_developer *
mitsubishielectric gx_logviewer *
mitsubishielectric gx_works2 *
mitsubishielectric gx_works3 *
mitsubishielectric iq_works *
mitsubishielectric mi_configurator *
mitsubishielectric mr_configurator *
mitsubishielectric mr_configurator2 *
mitsubishielectric mx_component *
mitsubishielectric mx_opc_server_da\/ua *
mitsubishielectric numerical_control_device_communication *
mitsubishielectric px_developer\/monitor_tool *
mitsubishielectric rt_toolbox3 *
mitsubishielectric rt_visualbox *
mitsubishielectric mrzjw3-mc2-utl_firmware *
mitsubishielectric mrzjw3-mc2-utl -
mitsubishielectric sw0dnc-mneth-b_firmware *
mitsubishielectric sw0dnc-mneth-b -
mitsubishielectric sw1dnc-ccbd2-b_firmware *
mitsubishielectric sw1dnc-ccbd2-b -
mitsubishielectric sw1dnc-ccief-j_firmware *
mitsubishielectric sw1dnc-ccief-j -
mitsubishielectric sw1dnc-ccief-b_firmware *
mitsubishielectric sw1dnc-ccief-b -
mitsubishielectric sw1dnc-mnetg-b_firmware *
mitsubishielectric sw1dnc-mnetg-b -
mitsubishielectric sw1dnc-qsccf-b_firmware *
mitsubishielectric sw1dnc-qsccf-b -
mitsubishielectric sw1dnd-emsdk-b_firmware *
mitsubishielectric sw1dnd-emsdk-b -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:jungo:windriver:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8F8C8AAC-5EF2-477E-9A84-95BF96FA76CD",
              "versionEndExcluding": "16.2.0",
              "versionStartIncluding": "6.0.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:cpu_module_logging_configuration_tool:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "463EA623-0DC2-4287-A9AC-837CBDECF76C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:cw_configurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E798352C-E09B-4D18-B3A8-CFCDE0AD3675",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:data_transfer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "21CC610A-0561-46A1-9077-D01D5C3F1A8F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:data_transfer_classic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B36ABBC-DB27-44D1-B844-00DFC3BBF043",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:ezsocket:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C6E4BC24-6583-4791-9ED9-D2D675187DCD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:fr_configurator_sw3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D236ABC2-93E4-4428-B949-7E17945E4D98",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:fr_configurator2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CED78B28-BBBF-4869-BC1C-F0789867FB4C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:genesis64:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C79890F-0B41-4855-84EE-78D5896C87A1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_got1000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4400D339-BB12-414A-B891-B6105D7FCA39",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_got2000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6871A74E-8B92-4892-970F-757F404590CB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_softgot1000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "03DE7DE4-DC4B-40F3-BB22-B8E524081942",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_softgot2000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9F8037F0-C124-4EFB-AEA1-89441975D36F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_developer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9C37E74B-DA76-4E59-953E-C50D0D75804A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_logviewer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B0B195E2-6076-487C-899F-A40B886BA556",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6C4E7C31-D08D-487F-B7FF-9502783FFDB9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F4AEDEEE-5070-41E2-B4DC-6DE8456BC028",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:iq_works:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7097AFD0-5A8C-4C62-AAF7-16FB71DE210C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mi_configurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A661B972-912C-4DAA-9518-CC01E0EB1A81",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mr_configurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "76C1D9F0-48A8-4193-A781-B19ACE1B0B4B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mr_configurator2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9FB81A97-4BE8-4570-914F-304F38968613",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mx_component:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CE14782A-4AD2-4633-8A3A-D81D5C434046",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mx_opc_server_da\\/ua:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A1BABCB-EDD7-4B1D-AE49-77DD1A3CCB1C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:numerical_control_device_communication:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4F89B350-B20F-45A8-8809-E9776C319591",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:px_developer\\/monitor_tool:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2B10E09F-84F3-42E3-9B8D-DE309ED4A4B4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:rt_toolbox3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7C12A1AA-66F0-452F-9B75-562F4A979CBD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:rt_visualbox:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "33A13944-145E-453E-A409-BE4A984619AA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:mrzjw3-mc2-utl_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A10A8E35-923F-483B-A924-441B78FFCF6D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:mrzjw3-mc2-utl:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "938DDBFF-A0CC-4311-9F30-08ABDBB67742",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw0dnc-mneth-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB49716D-8E0B-4E4C-B206-104BB64F6301",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw0dnc-mneth-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C8B0237-9A91-4954-AFBE-E661467D842A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-ccbd2-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B3B0B5A-27F2-4E08-8B75-1EAAC4DC840D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-ccbd2-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0B80AF0C-EFED-4CA0-B990-0ADA6F1D0AEE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-ccief-j_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B4348FF-8691-4832-9103-F46282924299",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-ccief-j:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "07737420-567D-49CC-9A9E-555038DFF0AA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-ccief-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5D3A5D57-DB2C-429F-BB3F-8EB7F4767E1D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-ccief-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FD4CA442-BC30-407E-851E-E03037E75E8D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-mnetg-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9826969F-D449-4032-8A0B-050D7CC3B1AE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-mnetg-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "858F9CAA-E6D3-4F1D-923D-ED9E05C3AC54",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-qsccf-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "61A13AD1-22F7-4FFD-BCB7-A4FDAF2BA659",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-qsccf-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "009853DA-ACAE-4928-AE90-090A3739BD39",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnd-emsdk-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "476C7885-89D2-4A6C-94FE-E06B55A23E37",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnd-emsdk-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9DF10CF6-1C1D-4768-A349-1AEFD26F491A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Improper privilege management in Jungo WinDriver 6.0.0 through 16.1.0 allows local attackers to escalate privileges and execute arbitrary code."
    },
    {
      "lang": "es",
      "value": "La gesti\u00f3n inadecuada de privilegios en Jungo WinDriver 6.0.0 a 16.1.0 permite a atacantes locales escalar privilegios y ejecutar c\u00f3digo arbitrario."
    }
  ],
  "id": "CVE-2024-26314",
  "lastModified": "2024-11-21T09:02:21.567",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-07-02T16:15:04.330",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Release Notes"
      ],
      "url": "https://jungo.com/windriver/versions/"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-04"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-001_en.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Release Notes"
      ],
      "url": "https://jungo.com/windriver/versions/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-04"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-001_en.pdf"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-11-25 00:15
Modified
2024-11-21 06:59
Summary
Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.090U, GT Designer3 Version1 (GOT2000) versions from 1.122C to 1.290C and Motion Control Setting(GX Works3 related software) versions from 1.035M to 1.042U allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users may view programs and project files or execute programs illegally.
Impacted products



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A868567B-2BAA-45AE-AEC9-3AFEF2361297",
              "versionEndIncluding": "1.011m",
              "versionStartIncluding": "1.000a",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "56BD062B-0D41-42E2-B9EF-B7FBB514CFF9",
              "versionEndIncluding": "1.086q",
              "versionStartIncluding": "1.015r",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C7C6A654-1B83-4743-8DDE-B8C5AA5C4D2A",
              "versionStartIncluding": "1.087r",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.090U, GT Designer3 Version1 (GOT2000) versions from 1.122C to 1.290C and Motion Control Setting(GX Works3 related software) versions from 1.035M to 1.042U allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users may view programs and project files or execute programs illegally."
    },
    {
      "lang": "es",
      "value": "Uso de vulnerabilidad de clave criptogr\u00e1fica codificada en Mitsubishi Electric GX Works3 las versiones desde 1.000A hasta 1.090U, GT Designer3 Versi\u00f3n1 (GOT2000) desde 1.122C hasta 1.290C y Motion Control Setting (software relacionado con GX Works3) desde 1.035M hasta 1.042U \npermite que un atacante remoto no autenticado revele informaci\u00f3n sensible. Como resultado, los usuarios no autenticados pueden ver programas y archivos de proyectos o ejecutar programas ilegalmente."
    }
  ],
  "id": "CVE-2022-29829",
  "lastModified": "2024-11-21T06:59:46.187",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 6.8,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.2,
        "impactScore": 4.0,
        "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-11-25T00:15:10.297",
  "references": [
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://jvn.jp/vu/JVNVU97244961/index.html"
    },
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"
    },
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://jvn.jp/vu/JVNVU97244961/index.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
    }
  ],
  "sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-321"
        }
      ],
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-798"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-11-25 00:15
Modified
2024-11-21 06:59
Summary
Use of Hard-coded Password vulnerability in Mitsubishi Electric Corporation GX Works3 versions from 1.015R to 1.095Z allows a remote unauthenticated attacker to obtain information about the project file for MELSEC safety CPU modules.
Impacted products



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "56BD062B-0D41-42E2-B9EF-B7FBB514CFF9",
              "versionEndIncluding": "1.086q",
              "versionStartIncluding": "1.015r",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C7C6A654-1B83-4743-8DDE-B8C5AA5C4D2A",
              "versionStartIncluding": "1.087r",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Use of Hard-coded Password vulnerability in Mitsubishi Electric Corporation GX Works3 versions from 1.015R to 1.095Z allows a remote unauthenticated attacker to obtain information about the project file for MELSEC safety CPU modules."
    },
    {
      "lang": "es",
      "value": "El uso de la vulnerabilidad de contrase\u00f1a codificada en Mitsubishi Electric Corporation GX Works3 desde la versi\u00f3n 1.015R hasta 1.095Z permite a un atacante remoto no autenticado obtener informaci\u00f3n sobre el archivo de proyecto para los m\u00f3dulos de CPU de seguridad MELSEC."
    }
  ],
  "id": "CVE-2022-29831",
  "lastModified": "2024-11-21T06:59:46.443",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-11-25T00:15:10.437",
  "references": [
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://jvn.jp/vu/JVNVU97244961"
    },
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"
    },
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://jvn.jp/vu/JVNVU97244961"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
    }
  ],
  "sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-259"
        }
      ],
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-798"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-07-02 15:15
Modified
2024-11-21 08:38
Summary
Denial of Service (DoS) vulnerability in Jungo WinDriver before 12.1.0 allows local attackers to cause a Windows blue screen error.
Impacted products
Vendor Product Version
jungo windriver *
mitsubishielectric cpu_module_logging_configuration_tool *
mitsubishielectric cw_configurator *
mitsubishielectric data_transfer *
mitsubishielectric data_transfer_classic *
mitsubishielectric ezsocket *
mitsubishielectric fr_configurator_sw3 *
mitsubishielectric fr_configurator2 *
mitsubishielectric genesis64 *
mitsubishielectric gt_got1000 *
mitsubishielectric gt_got2000 *
mitsubishielectric gt_softgot1000 *
mitsubishielectric gt_softgot2000 *
mitsubishielectric gx_developer *
mitsubishielectric gx_logviewer *
mitsubishielectric gx_works2 *
mitsubishielectric gx_works3 *
mitsubishielectric iq_works *
mitsubishielectric mi_configurator *
mitsubishielectric mr_configurator *
mitsubishielectric mr_configurator2 *
mitsubishielectric mx_component *
mitsubishielectric mx_opc_server_da\/ua *
mitsubishielectric numerical_control_device_communication *
mitsubishielectric px_developer\/monitor_tool *
mitsubishielectric rt_toolbox3 *
mitsubishielectric rt_visualbox *
mitsubishielectric mrzjw3-mc2-utl_firmware *
mitsubishielectric mrzjw3-mc2-utl -
mitsubishielectric sw0dnc-mneth-b_firmware *
mitsubishielectric sw0dnc-mneth-b -
mitsubishielectric sw1dnc-ccbd2-b_firmware *
mitsubishielectric sw1dnc-ccbd2-b -
mitsubishielectric sw1dnc-ccief-j_firmware *
mitsubishielectric sw1dnc-ccief-j -
mitsubishielectric sw1dnc-ccief-b_firmware *
mitsubishielectric sw1dnc-ccief-b -
mitsubishielectric sw1dnc-mnetg-b_firmware *
mitsubishielectric sw1dnc-mnetg-b -
mitsubishielectric sw1dnc-qsccf-b_firmware *
mitsubishielectric sw1dnc-qsccf-b -
mitsubishielectric sw1dnd-emsdk-b_firmware *
mitsubishielectric sw1dnd-emsdk-b -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:jungo:windriver:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B3FD78BE-8090-4C8C-B6E3-539B78958FBD",
              "versionEndExcluding": "12.1.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:cpu_module_logging_configuration_tool:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "463EA623-0DC2-4287-A9AC-837CBDECF76C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:cw_configurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E798352C-E09B-4D18-B3A8-CFCDE0AD3675",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:data_transfer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "21CC610A-0561-46A1-9077-D01D5C3F1A8F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:data_transfer_classic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B36ABBC-DB27-44D1-B844-00DFC3BBF043",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:ezsocket:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C6E4BC24-6583-4791-9ED9-D2D675187DCD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:fr_configurator_sw3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D236ABC2-93E4-4428-B949-7E17945E4D98",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:fr_configurator2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CED78B28-BBBF-4869-BC1C-F0789867FB4C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:genesis64:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C79890F-0B41-4855-84EE-78D5896C87A1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_got1000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4400D339-BB12-414A-B891-B6105D7FCA39",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_got2000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6871A74E-8B92-4892-970F-757F404590CB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_softgot1000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "03DE7DE4-DC4B-40F3-BB22-B8E524081942",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_softgot2000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9F8037F0-C124-4EFB-AEA1-89441975D36F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_developer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9C37E74B-DA76-4E59-953E-C50D0D75804A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_logviewer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B0B195E2-6076-487C-899F-A40B886BA556",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6C4E7C31-D08D-487F-B7FF-9502783FFDB9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F4AEDEEE-5070-41E2-B4DC-6DE8456BC028",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:iq_works:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7097AFD0-5A8C-4C62-AAF7-16FB71DE210C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mi_configurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A661B972-912C-4DAA-9518-CC01E0EB1A81",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mr_configurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "76C1D9F0-48A8-4193-A781-B19ACE1B0B4B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mr_configurator2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9FB81A97-4BE8-4570-914F-304F38968613",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mx_component:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CE14782A-4AD2-4633-8A3A-D81D5C434046",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mx_opc_server_da\\/ua:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A1BABCB-EDD7-4B1D-AE49-77DD1A3CCB1C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:numerical_control_device_communication:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4F89B350-B20F-45A8-8809-E9776C319591",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:px_developer\\/monitor_tool:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2B10E09F-84F3-42E3-9B8D-DE309ED4A4B4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:rt_toolbox3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7C12A1AA-66F0-452F-9B75-562F4A979CBD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:rt_visualbox:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "33A13944-145E-453E-A409-BE4A984619AA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:mrzjw3-mc2-utl_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A10A8E35-923F-483B-A924-441B78FFCF6D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:mrzjw3-mc2-utl:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "938DDBFF-A0CC-4311-9F30-08ABDBB67742",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw0dnc-mneth-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB49716D-8E0B-4E4C-B206-104BB64F6301",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw0dnc-mneth-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C8B0237-9A91-4954-AFBE-E661467D842A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-ccbd2-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B3B0B5A-27F2-4E08-8B75-1EAAC4DC840D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-ccbd2-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0B80AF0C-EFED-4CA0-B990-0ADA6F1D0AEE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-ccief-j_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B4348FF-8691-4832-9103-F46282924299",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-ccief-j:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "07737420-567D-49CC-9A9E-555038DFF0AA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-ccief-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5D3A5D57-DB2C-429F-BB3F-8EB7F4767E1D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-ccief-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FD4CA442-BC30-407E-851E-E03037E75E8D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-mnetg-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9826969F-D449-4032-8A0B-050D7CC3B1AE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-mnetg-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "858F9CAA-E6D3-4F1D-923D-ED9E05C3AC54",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-qsccf-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "61A13AD1-22F7-4FFD-BCB7-A4FDAF2BA659",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-qsccf-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "009853DA-ACAE-4928-AE90-090A3739BD39",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnd-emsdk-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "476C7885-89D2-4A6C-94FE-E06B55A23E37",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnd-emsdk-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9DF10CF6-1C1D-4768-A349-1AEFD26F491A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Denial of Service (DoS) vulnerability in Jungo WinDriver before 12.1.0 allows local attackers to cause a Windows blue screen error."
    },
    {
      "lang": "es",
      "value": "Vulnerabilidad de denegaci\u00f3n de servicio (DoS) en Jungo WinDriver anterior a 12.1.0 permite a atacantes locales provocar un error de pantalla azul de Windows."
    }
  ],
  "id": "CVE-2023-51777",
  "lastModified": "2024-11-21T08:38:46.883",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 5.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 5.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 3.6,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-07-02T15:15:10.807",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Release Notes"
      ],
      "url": "https://jungo.com/windriver/versions/"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-04"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-001_en.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Release Notes"
      ],
      "url": "https://jungo.com/windriver/versions/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-04"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-001_en.pdf"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-02-19 20:15
Modified
2024-11-21 05:46
Severity ?
Summary
Heap-based buffer overflow vulnerability in Mitsubishi Electric FA Engineering Software (CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT SoftGOT1000 Version3 versions 3.245F and prior, GT SoftGOT2000 Version1 versions 1.250L and prior, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer versions 8.506C and prior, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer versions 1.115U and prior, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, iQ Monozukuri ANDON (Data Transfer) all versions, iQ Monozukuri Process Remote Monitoring (Data Transfer) all versions, M_CommDTM-HART all versions, M_CommDTM-IO-Link versions 1.03D and prior, MELFA-Works versions 4.4 and prior, MELSEC WinCPU Setting Utility all versions, MELSOFT EM Software Development Kit (EM Configurator) versions 1.015R and prior, MELSOFT Navigator versions 2.74C and prior, MH11 SettingTool Version2 versions 2.004E and prior, MI Configurator versions 1.004E and prior, MT Works2 versions 1.167Z and prior, MX Component versions 5.001B and prior, Network Interface Board CC IE Control utility versions 1.29F and prior, Network Interface Board CC IE Field Utility versions 1.16S and prior, Network Interface Board CC-Link Ver.2 Utility versions 1.23Z and prior, Network Interface Board MNETH utility versions 34L and prior, PX Developer versions 1.53F and prior, RT ToolBox2 versions 3.73B and prior, RT ToolBox3 versions 1.82L and prior, Setting/monitoring tools for the C Controller module (SW4PVC-CCPU) versions 4.12N and prior and SLMP Data Collector versions 1.04E and prior) allows a remote unauthenticated attacker to cause a DoS condition of the software products, and possibly to execute a malicious program on the personal computer running the software products although it has not been reproduced, by spoofing MELSEC, GOT or FREQROL and returning crafted reply packets.
Impacted products
Vendor Product Version
mitsubishielectric c_controller_module_setting_and_monitoring_tool *
mitsubishielectric cpu_module_logging_configuration_tool *
mitsubishielectric cw_configurator *
mitsubishielectric data_transfer *
mitsubishielectric ezsocket *
mitsubishielectric fr_configurator *
mitsubishielectric fr_configurator_sw3 *
mitsubishielectric fr_configurator2 *
mitsubishielectric gt_designer3 *
mitsubishielectric gt_softgot1000 *
mitsubishielectric gt_softgot2000 *
mitsubishielectric gx_configurator-dp *
mitsubishielectric gx_configurator-qp *
mitsubishielectric gx_developer *
mitsubishielectric gx_explorer *
mitsubishielectric gx_iec_developer *
mitsubishielectric gx_logviewer *
mitsubishielectric gx_remoteservice-i *
mitsubishielectric gx_works2 *
mitsubishielectric gx_works3 *
mitsubishielectric iq_monozukuri_andon -
mitsubishielectric iq_monozukuri_process_remote_monitoring -
mitsubishielectric m_commdtm-hart *
mitsubishielectric m_commdtm-io-link *
mitsubishielectric melfa-works *
mitsubishielectric melsec_wincpu_setting_utility *
mitsubishielectric melsoft_em_software_development_kit *
mitsubishielectric melsoft_navigator *
mitsubishielectric mh11_settingtool_version2 *
mitsubishielectric mi_configurator *
mitsubishielectric mt_works2 *
mitsubishielectric mx_component *
mitsubishielectric network_interface_board_cc-link *
mitsubishielectric network_interface_board_cc_ie_control_utility *
mitsubishielectric network_interface_board_cc_ie_field_utility *
mitsubishielectric network_interface_board_mneth_utility *
mitsubishielectric px_developer *
mitsubishielectric rt_toolbox2 *
mitsubishielectric rt_toolbox3 *
mitsubishielectric setting\/monitoring_tools_for_the_c_controller_module *
mitsubishielectric slmp_data_collector *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:c_controller_module_setting_and_monitoring_tool:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4DB4A4DA-DBC0-42A8-B933-933DE45F004D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:cpu_module_logging_configuration_tool:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D83BA6D0-2A25-4DDA-B7BA-DE11FA55D276",
              "versionEndIncluding": "1.112r",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:cw_configurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "91D2BDFB-0A0A-4A1B-8671-8B5D652253DE",
              "versionEndIncluding": "1.011m",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:data_transfer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6AF9A2A7-6F9E-4CA9-8485-3AF83A6411DD",
              "versionEndIncluding": "3.44w",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:ezsocket:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C6E4BC24-6583-4791-9ED9-D2D675187DCD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:fr_configurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1773F87D-7E58-4E00-90B7-92BDDB4AA3BF",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:fr_configurator_sw3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D236ABC2-93E4-4428-B949-7E17945E4D98",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:fr_configurator2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "18E81D47-F88A-481B-98E0-56C52CDF6C8B",
              "versionEndIncluding": "1.24a",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_designer3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "66DEB37E-A837-4A2F-9660-7DE8441004D7",
              "versionEndIncluding": "1.250l",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_softgot1000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B835ECE8-6923-47DF-9BB8-E0AA8D77228D",
              "versionEndIncluding": "3.245f",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_softgot2000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "92C96AF0-1DCE-4769-AAC4-422F8B411A2A",
              "versionEndIncluding": "1.250l",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_configurator-dp:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E767C69A-23D9-4C67-AA66-392D5E70ED7B",
              "versionEndIncluding": "7.14q",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_configurator-qp:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "492299CE-FE94-4CB4-9D62-03F05CBCDE74",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_developer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C4588898-2ABA-4AA3-A33F-551387DC84AC",
              "versionEndIncluding": "8.506c",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_explorer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "18A18533-FF83-4C7C-839D-077A7523DBDC",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_iec_developer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "974700B4-FC0B-4097-8826-CE055E13434F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_logviewer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6FFEE46E-C37D-4E82-BDC5-1225C03BFFFE",
              "versionEndIncluding": "1.115u",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_remoteservice-i:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C4DAEEF5-50CA-4DCD-8B1A-BAE8DEEA23AA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "76E34DC3-5D48-49DB-B1CB-CB5BDDED169D",
              "versionEndIncluding": "1.597x",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "920FC6C1-32FA-4251-81AA-B76D353B216A",
              "versionEndIncluding": "1.070y",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:iq_monozukuri_andon:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "07756207-64DF-4F89-B3A1-19086CCC42BB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:iq_monozukuri_process_remote_monitoring:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "978160CD-B7D4-4494-A5BB-CA0195441985",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:m_commdtm-hart:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EBC92717-C371-42B4-8AA6-73E14B60A87E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:m_commdtm-io-link:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "87B55AB8-B00D-4960-9F31-45E1855B109E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:melfa-works:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4116C452-19C3-4F48-8A05-864BD884BDD0",
              "versionEndIncluding": "4.4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:melsec_wincpu_setting_utility:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C51CF8E-49C1-418C-B410-50B23F9A23D7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:melsoft_em_software_development_kit:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "724C0E0B-5658-4040-A925-A07128EAD323",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:melsoft_navigator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0DC7353B-EFF7-432D-8F88-0D5EBBBBE4C0",
              "versionEndIncluding": "2.74c",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mh11_settingtool_version2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A8D3CBAF-5876-4DCE-908F-CCA8B0DDDB75",
              "versionEndIncluding": "2.004e",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mi_configurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A661B972-912C-4DAA-9518-CC01E0EB1A81",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mt_works2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "57031F64-353E-403C-B7F8-0A145E70CBE7",
              "versionEndIncluding": "1.167z",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mx_component:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3B623A09-688E-49B1-99EF-CFA8DADC79E8",
              "versionEndIncluding": "5.001b",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:network_interface_board_cc-link:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "87A92A26-7148-4A2A-BAFA-5F819468F48E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:network_interface_board_cc_ie_control_utility:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4D02C00E-B8C6-4987-8F25-E3D46FEDB44A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:network_interface_board_cc_ie_field_utility:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "07F71BF3-FC69-4DA3-9989-DA269B557085",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:network_interface_board_mneth_utility:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "171CD9BC-2A02-4ACA-B29C-332094AA3EDA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:px_developer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "445EF081-A7BB-4568-850F-00CF58060D62",
              "versionEndIncluding": "1.53f",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:rt_toolbox2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5BD4EC4A-ACF7-45F2-893D-569B4F8F8909",
              "versionEndIncluding": "3.73b",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:rt_toolbox3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "779B0C13-D3DD-4D27-B18B-C0119B7BC5CB",
              "versionEndIncluding": "1.82l",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:setting\\/monitoring_tools_for_the_c_controller_module:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "85CBC7FE-6EF9-4DA5-8128-849233A8DC72",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:slmp_data_collector:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8814A8BA-AA54-4270-AAB1-679D0881D715",
              "versionEndIncluding": "1.04e",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Heap-based buffer overflow vulnerability in Mitsubishi Electric FA Engineering Software (CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT SoftGOT1000 Version3 versions 3.245F and prior, GT SoftGOT2000 Version1 versions 1.250L and prior, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer versions 8.506C and prior, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer versions 1.115U and prior, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, iQ Monozukuri ANDON (Data Transfer) all versions, iQ Monozukuri Process Remote Monitoring (Data Transfer) all versions, M_CommDTM-HART all versions, M_CommDTM-IO-Link versions 1.03D and prior, MELFA-Works versions 4.4 and prior, MELSEC WinCPU Setting Utility all versions, MELSOFT EM Software Development Kit (EM Configurator) versions 1.015R and prior, MELSOFT Navigator versions 2.74C and prior, MH11 SettingTool Version2 versions 2.004E and prior, MI Configurator versions 1.004E and prior, MT Works2 versions 1.167Z and prior, MX Component versions 5.001B and prior, Network Interface Board CC IE Control utility versions 1.29F and prior, Network Interface Board CC IE Field Utility versions 1.16S and prior, Network Interface Board CC-Link Ver.2 Utility versions 1.23Z and prior, Network Interface Board MNETH utility versions 34L and prior, PX Developer versions 1.53F and prior, RT ToolBox2 versions 3.73B and prior, RT ToolBox3 versions 1.82L and prior, Setting/monitoring tools for the C Controller module (SW4PVC-CCPU) versions 4.12N and prior and SLMP Data Collector versions 1.04E and prior) allows a remote unauthenticated attacker to cause a DoS condition of the software products, and possibly to execute a malicious program on the personal computer running the software products although it has not been reproduced, by spoofing MELSEC, GOT or FREQROL and returning crafted reply packets."
    },
    {
      "lang": "es",
      "value": "Vulnerabilidad de desbordamiento de b\u00fafer basada en Heap en el software de ingenier\u00eda de Mitsubishi Electric FA (CPU Module Logging Configuration Tool versiones 1.112R y anteriores, CW Configurator versiones 1.011M y anteriores, Data Transfer versiones 3.44W y anteriores, EZSocket versiones 5.4 y anteriores, FR Configurator todas las versiones, FR Configurator SW3 todas las versiones, FR Configurator2 versiones 1.24A y anteriores, GT Designer3 Version1(GOT1000) versiones 1. 250L y anteriores, GT Designer3 Version1(GOT2000) versiones 1.250L y anteriores, GT SoftGOT1000 Version3 versiones 3.245F y anteriores, GT SoftGOT2000 Version1 versiones 1.250L y anteriores, GX Configurator-DP versiones 7. 14Q y anteriores, GX Configurator-QP todas las versiones, GX Developer versiones 8.506C y anteriores, GX Explorer todas las versiones, GX IEC Developer todas las versiones, GX LogViewer versiones 1.115U y anteriores, GX RemoteService-I todas las versiones, GX Works2 versiones 1. 597X y anteriores, GX Works3 versiones 1.070Y y anteriores, iQ Monozukuri ANDON (Data Transfer) todas las versiones, iQ Monozukuri Process Remote Monitoring (Data Transfer) todas las versiones, M_CommDTM-HART todas las versiones, M_CommDTM-IO-Link versiones 1.03D y anteriores, MELFA-Works versiones 4.4 y anteriores, MELSEC WinCPU Setting Utility todas las versiones, MELSOFT EM Software Development Kit (EM Configurator) versiones 1. 015R y anteriores, MELSOFT Navigator versiones 2.74C y anteriores, MH11 SettingTool Version2 versiones 2.004E y anteriores, MI Configurator versiones 1.004E y anteriores, MT Works2 versiones 1.167Z y anteriores, MX Component versiones 5.001B y anteriores, Network Interface Board CC IE Control utility versiones 1.29F y anteriores, Network Interface Board CC IE Field Utility versiones 1.16S y anteriores, Network Interface Board CC-Link Ver.2 1.23Z y anteriores, Network Interface Board MNETH utility versions 34L y anteriores, PX Developer versions 1.53F y anteriores, RT ToolBox2 versions 3.73B y anteriores, RT ToolBox3 versions 1.82L y anteriores, Setting/monitoring tools for the C Controller module (SW4PVC-CCPU) versions 4.12N y anteriores y SLMP Data Collector versions 1. 04E y anteriores) permite que un atacante remoto no autenticado provoque una condici\u00f3n de denegaci\u00f3n de servicio de los productos de software, y posiblemente ejecute un programa malicioso en el ordenador personal que ejecuta los productos de software, aunque no se ha reproducido, mediante la suplantaci\u00f3n de MELSEC, GOT o FREQROL y el retorno de paquetes de respuesta manipulados"
    }
  ],
  "id": "CVE-2021-20587",
  "lastModified": "2024-11-21T05:46:49.637",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 7.5,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-02-19T20:15:12.833",
  "references": [
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://jvn.jp/vu/JVNVU92330101/index.html"
    },
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-049-02"
    },
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-021_en.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://jvn.jp/vu/JVNVU92330101/index.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-049-02"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-021_en.pdf"
    }
  ],
  "sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-01-30 09:15
Modified
2024-11-21 08:44
Summary
Use of Externally-Controlled Input to Select Classes or Code ('Unsafe Reflection') vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 and later, GT Designer3 Version1(GOT1000) all versions, GT Designer3 Version1(GOT2000) all versions, GX Works2 versions 1.11M and later, GX Works3 versions 1.106L and prior, MELSOFT Navigator versions 1.04E and later, MT Works2 all versions, MX Component versions 4.00A and later and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to execute a malicious code by RPC with a path to a malicious library while connected to the products.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:ezsocket:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C6096E48-9ECD-48FF-9F5E-D182E42D41C9",
              "versionStartIncluding": "3.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:fr_configurator2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CED78B28-BBBF-4869-BC1C-F0789867FB4C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:got1000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C31EFBDE-DE71-46F3-97A1-CABC037FC31D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:got2000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5D887323-BBDD-41ED-82B8-66DE412666F5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B73766EB-FF3E-495E-B1C1-5D49A1569696",
              "versionStartIncluding": "1.11m",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F4AEDEEE-5070-41E2-B4DC-6DE8456BC028",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mc_works64:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E5790F2E-5511-46F6-94E5-F3E1A2367662",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:melsoft_navigator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5F3C096D-D510-46F4-B46A-A234CA630227",
              "versionStartIncluding": "1.04e",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mt_works2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0EC0ACF4-C303-4EC0-A755-1F9AE4152DDB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mx_component:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "407781DB-9AF9-4E3A-BF24-1787ADB33F42",
              "versionStartIncluding": "4.00a",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Use of Externally-Controlled Input to Select Classes or Code (\u0027Unsafe Reflection\u0027) vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 and later, GT Designer3 Version1(GOT1000) all versions, GT Designer3 Version1(GOT2000) all versions, GX Works2 versions 1.11M and later, GX Works3 versions 1.106L and prior, MELSOFT Navigator versions 1.04E and later, MT Works2 all versions, MX Component versions 4.00A and later and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to execute a malicious code by RPC with a path to a malicious library while connected to the products."
    },
    {
      "lang": "es",
      "value": "Vulnerabilidad de uso de entrada controlada externamente para seleccionar clases o c\u00f3digo (\"Reflexi\u00f3n insegura\") en Mitsubishi Electric Corporation EZSocket versiones 3.0 y posteriores, FR Configurator2 todas las versiones, GT Designer3 Versi\u00f3n1(GOT1000) todas las versiones, GT Designer3 Versi\u00f3n1(GOT2000) todas las versiones , GX Works2 versiones 1.11M y posteriores, GX Works3 todas las versiones, MELSOFT Navigator versiones 1.04E y posteriores, MT Works2 todas las versiones, MX Component versiones 4.00A y posteriores y MX OPC Server DA/UA todas las versiones permiten que un atacante remoto no autenticado ejecute un c\u00f3digo malicioso por RPC con una ruta a una librer\u00eda maliciosa mientras est\u00e1 conectado a los productos."
    }
  ],
  "id": "CVE-2023-6943",
  "lastModified": "2024-11-21T08:44:53.360",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-01-30T09:15:47.960",
  "references": [
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://jvn.jp/vu/JVNVU95103362"
    },
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-030-02"
    },
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-020_en.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://jvn.jp/vu/JVNVU95103362"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-030-02"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-020_en.pdf"
    }
  ],
  "sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-470"
        }
      ],
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-11-25 00:15
Modified
2024-11-21 06:59
Summary
Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.087R and Motion Control Setting(GX Works3 related software) versions from 1.000A to 1.042U allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users may view programs and project files or execute programs illegally.
Impacted products



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A868567B-2BAA-45AE-AEC9-3AFEF2361297",
              "versionEndIncluding": "1.011m",
              "versionStartIncluding": "1.000a",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "56BD062B-0D41-42E2-B9EF-B7FBB514CFF9",
              "versionEndIncluding": "1.086q",
              "versionStartIncluding": "1.015r",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.087R and Motion Control Setting(GX Works3 related software) versions from 1.000A to 1.042U allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users may view programs and project files or execute programs illegally."
    },
    {
      "lang": "es",
      "value": "Vulnerabilidad de almacenamiento de texto sin cifrar de informaci\u00f3n sensible en las versiones de Mitsubishi Electric GX Works3 de 1.000A a 1.087R y de Motion Control Setting (software relacionado con GX Works3) de 1.000A a 1.042U permite que un atacante remoto no autenticado revele informaci\u00f3n confidencial. Como resultado, los usuarios no autenticados pueden ver programas y archivos de proyectos o ejecutar programas ilegalmente."
    }
  ],
  "id": "CVE-2022-29826",
  "lastModified": "2024-11-21T06:59:45.787",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 6.8,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.2,
        "impactScore": 4.0,
        "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-11-25T00:15:10.080",
  "references": [
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://jvn.jp/vu/JVNVU97244961/index.html"
    },
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"
    },
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://jvn.jp/vu/JVNVU97244961/index.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
    }
  ],
  "sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-312"
        }
      ],
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-312"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-07-02 16:15
Modified
2024-11-21 08:55
Summary
Denial of Service (DoS) vulnerability in Jungo WinDriver before 12.5.1 allows local attackers to cause a Windows blue screen error.
Impacted products
Vendor Product Version
jungo windriver *
mitsubishielectric cpu_module_logging_configuration_tool *
mitsubishielectric cw_configurator *
mitsubishielectric data_transfer *
mitsubishielectric data_transfer_classic *
mitsubishielectric ezsocket *
mitsubishielectric fr_configurator_sw3 *
mitsubishielectric fr_configurator2 *
mitsubishielectric genesis64 *
mitsubishielectric gt_got1000 *
mitsubishielectric gt_got2000 *
mitsubishielectric gt_softgot1000 *
mitsubishielectric gt_softgot2000 *
mitsubishielectric gx_developer *
mitsubishielectric gx_logviewer *
mitsubishielectric gx_works2 *
mitsubishielectric gx_works3 *
mitsubishielectric iq_works *
mitsubishielectric mi_configurator *
mitsubishielectric mr_configurator *
mitsubishielectric mr_configurator2 *
mitsubishielectric mx_component *
mitsubishielectric mx_opc_server_da\/ua *
mitsubishielectric numerical_control_device_communication *
mitsubishielectric px_developer\/monitor_tool *
mitsubishielectric rt_toolbox3 *
mitsubishielectric rt_visualbox *
mitsubishielectric mrzjw3-mc2-utl_firmware *
mitsubishielectric mrzjw3-mc2-utl -
mitsubishielectric sw0dnc-mneth-b_firmware *
mitsubishielectric sw0dnc-mneth-b -
mitsubishielectric sw1dnc-ccbd2-b_firmware *
mitsubishielectric sw1dnc-ccbd2-b -
mitsubishielectric sw1dnc-ccief-j_firmware *
mitsubishielectric sw1dnc-ccief-j -
mitsubishielectric sw1dnc-ccief-b_firmware *
mitsubishielectric sw1dnc-ccief-b -
mitsubishielectric sw1dnc-mnetg-b_firmware *
mitsubishielectric sw1dnc-mnetg-b -
mitsubishielectric sw1dnc-qsccf-b_firmware *
mitsubishielectric sw1dnc-qsccf-b -
mitsubishielectric sw1dnd-emsdk-b_firmware *
mitsubishielectric sw1dnd-emsdk-b -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:jungo:windriver:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CD5769FE-170B-4FCC-9A2E-B487C2DAFB16",
              "versionEndExcluding": "12.5.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:cpu_module_logging_configuration_tool:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "463EA623-0DC2-4287-A9AC-837CBDECF76C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:cw_configurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E798352C-E09B-4D18-B3A8-CFCDE0AD3675",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:data_transfer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "21CC610A-0561-46A1-9077-D01D5C3F1A8F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:data_transfer_classic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B36ABBC-DB27-44D1-B844-00DFC3BBF043",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:ezsocket:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C6E4BC24-6583-4791-9ED9-D2D675187DCD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:fr_configurator_sw3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D236ABC2-93E4-4428-B949-7E17945E4D98",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:fr_configurator2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CED78B28-BBBF-4869-BC1C-F0789867FB4C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:genesis64:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C79890F-0B41-4855-84EE-78D5896C87A1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_got1000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4400D339-BB12-414A-B891-B6105D7FCA39",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_got2000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6871A74E-8B92-4892-970F-757F404590CB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_softgot1000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "03DE7DE4-DC4B-40F3-BB22-B8E524081942",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_softgot2000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9F8037F0-C124-4EFB-AEA1-89441975D36F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_developer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9C37E74B-DA76-4E59-953E-C50D0D75804A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_logviewer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B0B195E2-6076-487C-899F-A40B886BA556",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6C4E7C31-D08D-487F-B7FF-9502783FFDB9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F4AEDEEE-5070-41E2-B4DC-6DE8456BC028",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:iq_works:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7097AFD0-5A8C-4C62-AAF7-16FB71DE210C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mi_configurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A661B972-912C-4DAA-9518-CC01E0EB1A81",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mr_configurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "76C1D9F0-48A8-4193-A781-B19ACE1B0B4B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mr_configurator2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9FB81A97-4BE8-4570-914F-304F38968613",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mx_component:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CE14782A-4AD2-4633-8A3A-D81D5C434046",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mx_opc_server_da\\/ua:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A1BABCB-EDD7-4B1D-AE49-77DD1A3CCB1C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:numerical_control_device_communication:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4F89B350-B20F-45A8-8809-E9776C319591",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:px_developer\\/monitor_tool:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2B10E09F-84F3-42E3-9B8D-DE309ED4A4B4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:rt_toolbox3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7C12A1AA-66F0-452F-9B75-562F4A979CBD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:rt_visualbox:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "33A13944-145E-453E-A409-BE4A984619AA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:mrzjw3-mc2-utl_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A10A8E35-923F-483B-A924-441B78FFCF6D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:mrzjw3-mc2-utl:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "938DDBFF-A0CC-4311-9F30-08ABDBB67742",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw0dnc-mneth-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB49716D-8E0B-4E4C-B206-104BB64F6301",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw0dnc-mneth-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C8B0237-9A91-4954-AFBE-E661467D842A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-ccbd2-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B3B0B5A-27F2-4E08-8B75-1EAAC4DC840D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-ccbd2-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0B80AF0C-EFED-4CA0-B990-0ADA6F1D0AEE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-ccief-j_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B4348FF-8691-4832-9103-F46282924299",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-ccief-j:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "07737420-567D-49CC-9A9E-555038DFF0AA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-ccief-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5D3A5D57-DB2C-429F-BB3F-8EB7F4767E1D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-ccief-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FD4CA442-BC30-407E-851E-E03037E75E8D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-mnetg-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9826969F-D449-4032-8A0B-050D7CC3B1AE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-mnetg-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "858F9CAA-E6D3-4F1D-923D-ED9E05C3AC54",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-qsccf-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "61A13AD1-22F7-4FFD-BCB7-A4FDAF2BA659",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-qsccf-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "009853DA-ACAE-4928-AE90-090A3739BD39",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnd-emsdk-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "476C7885-89D2-4A6C-94FE-E06B55A23E37",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnd-emsdk-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9DF10CF6-1C1D-4768-A349-1AEFD26F491A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Denial of Service (DoS) vulnerability in Jungo WinDriver before 12.5.1 allows local attackers to cause a Windows blue screen error."
    },
    {
      "lang": "es",
      "value": "Vulnerabilidad de denegaci\u00f3n de servicio (DoS) en Jungo WinDriver anterior a 12.5.1 permite a atacantes locales provocar un error de pantalla azul de Windows."
    }
  ],
  "id": "CVE-2024-22105",
  "lastModified": "2024-11-21T08:55:35.950",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 5.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-07-02T16:15:03.877",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Release Notes"
      ],
      "url": "https://jungo.com/windriver/versions/"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-04"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-001_en.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Release Notes"
      ],
      "url": "https://jungo.com/windriver/versions/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-04"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-001_en.pdf"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-404"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-07-02 15:15
Modified
2024-11-21 08:55
Summary
Out-of-Bounds Write vulnerability in Jungo WinDriver before 12.5.1 allows local attackers to cause a Windows blue screen error and Denial of Service (DoS).
Impacted products
Vendor Product Version
jungo windriver *
mitsubishielectric cpu_module_logging_configuration_tool *
mitsubishielectric cw_configurator *
mitsubishielectric data_transfer *
mitsubishielectric data_transfer_classic *
mitsubishielectric ezsocket *
mitsubishielectric fr_configurator_sw3 *
mitsubishielectric fr_configurator2 *
mitsubishielectric genesis64 *
mitsubishielectric gt_got1000 *
mitsubishielectric gt_got2000 *
mitsubishielectric gt_softgot1000 *
mitsubishielectric gt_softgot2000 *
mitsubishielectric gx_developer *
mitsubishielectric gx_logviewer *
mitsubishielectric gx_works2 *
mitsubishielectric gx_works3 *
mitsubishielectric iq_works *
mitsubishielectric mi_configurator *
mitsubishielectric mr_configurator *
mitsubishielectric mr_configurator2 *
mitsubishielectric mx_component *
mitsubishielectric mx_opc_server_da\/ua *
mitsubishielectric numerical_control_device_communication *
mitsubishielectric px_developer\/monitor_tool *
mitsubishielectric rt_toolbox3 *
mitsubishielectric rt_visualbox *
mitsubishielectric mrzjw3-mc2-utl_firmware *
mitsubishielectric mrzjw3-mc2-utl -
mitsubishielectric sw0dnc-mneth-b_firmware *
mitsubishielectric sw0dnc-mneth-b -
mitsubishielectric sw1dnc-ccbd2-b_firmware *
mitsubishielectric sw1dnc-ccbd2-b -
mitsubishielectric sw1dnc-ccief-j_firmware *
mitsubishielectric sw1dnc-ccief-j -
mitsubishielectric sw1dnc-ccief-b_firmware *
mitsubishielectric sw1dnc-ccief-b -
mitsubishielectric sw1dnc-mnetg-b_firmware *
mitsubishielectric sw1dnc-mnetg-b -
mitsubishielectric sw1dnc-qsccf-b_firmware *
mitsubishielectric sw1dnc-qsccf-b -
mitsubishielectric sw1dnd-emsdk-b_firmware *
mitsubishielectric sw1dnd-emsdk-b -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:jungo:windriver:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CD5769FE-170B-4FCC-9A2E-B487C2DAFB16",
              "versionEndExcluding": "12.5.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:cpu_module_logging_configuration_tool:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "463EA623-0DC2-4287-A9AC-837CBDECF76C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:cw_configurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E798352C-E09B-4D18-B3A8-CFCDE0AD3675",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:data_transfer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "21CC610A-0561-46A1-9077-D01D5C3F1A8F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:data_transfer_classic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B36ABBC-DB27-44D1-B844-00DFC3BBF043",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:ezsocket:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C6E4BC24-6583-4791-9ED9-D2D675187DCD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:fr_configurator_sw3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D236ABC2-93E4-4428-B949-7E17945E4D98",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:fr_configurator2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CED78B28-BBBF-4869-BC1C-F0789867FB4C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:genesis64:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C79890F-0B41-4855-84EE-78D5896C87A1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_got1000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4400D339-BB12-414A-B891-B6105D7FCA39",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_got2000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6871A74E-8B92-4892-970F-757F404590CB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_softgot1000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "03DE7DE4-DC4B-40F3-BB22-B8E524081942",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_softgot2000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9F8037F0-C124-4EFB-AEA1-89441975D36F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_developer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9C37E74B-DA76-4E59-953E-C50D0D75804A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_logviewer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B0B195E2-6076-487C-899F-A40B886BA556",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6C4E7C31-D08D-487F-B7FF-9502783FFDB9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F4AEDEEE-5070-41E2-B4DC-6DE8456BC028",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:iq_works:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7097AFD0-5A8C-4C62-AAF7-16FB71DE210C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mi_configurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A661B972-912C-4DAA-9518-CC01E0EB1A81",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mr_configurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "76C1D9F0-48A8-4193-A781-B19ACE1B0B4B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mr_configurator2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9FB81A97-4BE8-4570-914F-304F38968613",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mx_component:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CE14782A-4AD2-4633-8A3A-D81D5C434046",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mx_opc_server_da\\/ua:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A1BABCB-EDD7-4B1D-AE49-77DD1A3CCB1C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:numerical_control_device_communication:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4F89B350-B20F-45A8-8809-E9776C319591",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:px_developer\\/monitor_tool:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2B10E09F-84F3-42E3-9B8D-DE309ED4A4B4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:rt_toolbox3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7C12A1AA-66F0-452F-9B75-562F4A979CBD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:rt_visualbox:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "33A13944-145E-453E-A409-BE4A984619AA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:mrzjw3-mc2-utl_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A10A8E35-923F-483B-A924-441B78FFCF6D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:mrzjw3-mc2-utl:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "938DDBFF-A0CC-4311-9F30-08ABDBB67742",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw0dnc-mneth-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB49716D-8E0B-4E4C-B206-104BB64F6301",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw0dnc-mneth-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C8B0237-9A91-4954-AFBE-E661467D842A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-ccbd2-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B3B0B5A-27F2-4E08-8B75-1EAAC4DC840D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-ccbd2-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0B80AF0C-EFED-4CA0-B990-0ADA6F1D0AEE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-ccief-j_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B4348FF-8691-4832-9103-F46282924299",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-ccief-j:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "07737420-567D-49CC-9A9E-555038DFF0AA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-ccief-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5D3A5D57-DB2C-429F-BB3F-8EB7F4767E1D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-ccief-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FD4CA442-BC30-407E-851E-E03037E75E8D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-mnetg-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9826969F-D449-4032-8A0B-050D7CC3B1AE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-mnetg-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "858F9CAA-E6D3-4F1D-923D-ED9E05C3AC54",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-qsccf-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "61A13AD1-22F7-4FFD-BCB7-A4FDAF2BA659",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-qsccf-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "009853DA-ACAE-4928-AE90-090A3739BD39",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnd-emsdk-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "476C7885-89D2-4A6C-94FE-E06B55A23E37",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnd-emsdk-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9DF10CF6-1C1D-4768-A349-1AEFD26F491A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Out-of-Bounds Write vulnerability in Jungo WinDriver before 12.5.1 allows local attackers to cause a Windows blue screen error and Denial of Service (DoS)."
    },
    {
      "lang": "es",
      "value": "La vulnerabilidad de escritura fuera de los l\u00edmites en Jungo WinDriver anterior a 12.5.1 permite a atacantes locales provocar un error de pantalla azul de Windows y denegaci\u00f3n de servicio (DoS)."
    }
  ],
  "id": "CVE-2024-22104",
  "lastModified": "2024-11-21T08:55:35.653",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 5.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 5.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 3.6,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-07-02T15:15:11.227",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Release Notes"
      ],
      "url": "https://jungo.com/windriver/versions/"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-04"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-001_en.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Release Notes"
      ],
      "url": "https://jungo.com/windriver/versions/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-04"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-001_en.pdf"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-400"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-11-25 00:15
Modified
2024-11-21 06:51
Summary
Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Mitsubishi Electric MX OPC UA Module Configurator-R versions 1.08J and prior allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers can gain unauthorized access to the MELSEC CPU module and the MELSEC OPC UA server module.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A868567B-2BAA-45AE-AEC9-3AFEF2361297",
              "versionEndIncluding": "1.011m",
              "versionStartIncluding": "1.000a",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "56BD062B-0D41-42E2-B9EF-B7FBB514CFF9",
              "versionEndIncluding": "1.086q",
              "versionStartIncluding": "1.015r",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C7C6A654-1B83-4743-8DDE-B8C5AA5C4D2A",
              "versionStartIncluding": "1.087r",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mx_opc_ua_module_configurator-r:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "259C29BF-D845-42E4-8289-BD2FDBE77133",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Mitsubishi Electric MX OPC UA Module Configurator-R versions 1.08J and prior allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers can gain unauthorized access to the MELSEC CPU module and the MELSEC OPC UA server module."
    },
    {
      "lang": "es",
      "value": "Vulnerabilidad de almacenamiento de texto sin cifrar de informaci\u00f3n confidencial en Mitsubishi Electric GX Works3 versiones de 1.000A a 1.095Z y Mitsubishi Electric MX OPC UA Module Configurator-R versiones 1.08J y anteriores permite que un atacante remoto no autenticado revele informaci\u00f3n sensible. Como resultado, atacantes no autenticados pueden obtener acceso no autorizado al m\u00f3dulo de CPU de MELSEC y al m\u00f3dulo de servidor OPC UA de MELSEC."
    }
  ],
  "id": "CVE-2022-25164",
  "lastModified": "2024-11-21T06:51:43.907",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 8.6,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 4.0,
        "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-11-25T00:15:09.907",
  "references": [
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://jvn.jp/vu/JVNVU97244961/index.html"
    },
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"
    },
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://jvn.jp/vu/JVNVU97244961/index.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
    }
  ],
  "sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-312"
        }
      ],
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-312"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-02-11 18:15
Modified
2024-11-21 05:03
Summary
Multiple Mitsubishi Electric Factory Automation engineering software products have a malicious code execution vulnerability. A malicious attacker could use this vulnerability to obtain information, modify information, and cause a denial-of-service condition.
Impacted products
Vendor Product Version
mitsubishielectric c_controller_interface_module_utility *
mitsubishielectric c_controller_module_setting_and_monitoring_tool *
mitsubishielectric cc-link_ie_control_network_data_collector 1.00a
mitsubishielectric cc-link_ie_field_network_data_collector 1.00a
mitsubishielectric cc-link_ie_tsn_data_collector 1.00a
mitsubishielectric cpu_module_logging_configuration_tool *
mitsubishielectric cw_configurator *
mitsubishielectric data_transfer *
mitsubishielectric ezsocket *
mitsubishielectric fr_configurator_sw3 *
mitsubishielectric fr_configurator2 *
mitsubishielectric gt_designer2_classic *
mitsubishielectric gt_softgot1000 *
mitsubishielectric gt_softgot2000 *
mitsubishielectric gx_developer *
mitsubishielectric gx_logviewer *
mitsubishielectric gx_works2 *
mitsubishielectric gx_works3 *
mitsubishielectric m_commdtm-io-link *
mitsubishielectric melfa-works *
mitsubishielectric melsec_wincpu_setting_utility *
mitsubishielectric melsoft_complete_clean_up_tool *
mitsubishielectric melsoft_em_software_development_kit *
mitsubishielectric melsoft_iq_appportal *
mitsubishielectric melsoft_navigator *
mitsubishielectric mi_configurator *
mitsubishielectric motion_control_setting *
mitsubishielectric motorizer *
mitsubishielectric mr_configurator2 *
mitsubishielectric mt_works2 *
mitsubishielectric mtconnect_data_collector *
mitsubishielectric mx_component *
mitsubishielectric mx_mesinterface *
mitsubishielectric mx_mesinterface-r *
mitsubishielectric mx_sheet *
mitsubishielectric position_board_utility_2 *
mitsubishielectric px_developer *
mitsubishielectric rt_toolbox2 *
mitsubishielectric rt_toolbox3 *
mitsubishielectric setting\/monitoring_tools_for_the_c_controller_module *
mitsubishielectric slmp_data_collector *
mitsubishielectric gt_designer3 *
mitsubishielectric got1000_series_gt10 -
mitsubishielectric got1000_series_gt11 -
mitsubishielectric got1000_series_gt12 -
mitsubishielectric got1000_series_gt14 -
mitsubishielectric got1000_series_gt15 -
mitsubishielectric got1000_series_gt16 -
mitsubishielectric got1000_series_gt21 -
mitsubishielectric got1000_series_gt23 -
mitsubishielectric got1000_series_gt25 -
mitsubishielectric got1000_series_gt27 -
mitsubishielectric network_interface_board_cc-link_ver.2_utility_firmware *
mitsubishielectric network_interface_board_cc-link_ver.2_utility -
mitsubishielectric network_interface_board_cc_ie_control_utility_firmware *
mitsubishielectric network_interface_board_cc_ie_control_utility -
mitsubishielectric network_interface_board_cc_ie_field_utility_firmware *
mitsubishielectric network_interface_board_cc_ie_field_utility -
mitsubishielectric network_interface_board_mneth_utility_firmware *
mitsubishielectric network_interface_board_mneth_utility -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:c_controller_interface_module_utility:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "23DA824B-6169-477E-ABE6-251673287DBB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:c_controller_module_setting_and_monitoring_tool:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4DB4A4DA-DBC0-42A8-B933-933DE45F004D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:cc-link_ie_control_network_data_collector:1.00a:*:*:*:*:*:*:*",
              "matchCriteriaId": "147760E8-B888-481C-8669-C989B96CD642",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:cc-link_ie_field_network_data_collector:1.00a:*:*:*:*:*:*:*",
              "matchCriteriaId": "DD410E22-1E58-412B-8A03-2BDE25714E89",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:cc-link_ie_tsn_data_collector:1.00a:*:*:*:*:*:*:*",
              "matchCriteriaId": "82B337E7-3656-445B-9EA1-FEFC80C37819",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:cpu_module_logging_configuration_tool:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EFB022B0-D30E-4EA9-BDB3-BD5784144F45",
              "versionEndIncluding": "1.100e",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:cw_configurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "892E3CDC-AFC4-4EF1-AF46-3F161603DDB1",
              "versionEndIncluding": "1.010l",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:data_transfer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "45BCA319-1B52-468E-BB59-A2AA2C491361",
              "versionEndIncluding": "3.42u",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:ezsocket:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C0BF4793-8A65-4CB6-9B62-4388CBD84033",
              "versionEndIncluding": "5.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:fr_configurator_sw3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D236ABC2-93E4-4428-B949-7E17945E4D98",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:fr_configurator2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CED78B28-BBBF-4869-BC1C-F0789867FB4C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_designer2_classic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1B2B348C-0C2E-43A7-A606-102CB0E08B4B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_softgot1000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F21C6BDF-DD7F-4462-9F74-4A91E4BA936C",
              "versionEndIncluding": "3.200j",
              "versionStartIncluding": "3.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_softgot2000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EEF6E106-73A6-403B-A731-0372521E412D",
              "versionEndIncluding": "1.241b",
              "versionStartIncluding": "1.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_developer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5589F3F2-0857-4D95-9F63-EE66452BE566",
              "versionEndIncluding": "8.504a",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_logviewer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "591B76E1-665F-4473-8A65-B8549B61807F",
              "versionEndIncluding": "1.100e",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8E36C451-A531-4EEB-9574-0AC0116D910D",
              "versionEndIncluding": "1.601b",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AE537EF6-72AE-4091-AF6E-9959C3F45632",
              "versionEndIncluding": "1.063r",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:m_commdtm-io-link:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "87B55AB8-B00D-4960-9F31-45E1855B109E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:melfa-works:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4116C452-19C3-4F48-8A05-864BD884BDD0",
              "versionEndIncluding": "4.4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:melsec_wincpu_setting_utility:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C51CF8E-49C1-418C-B410-50B23F9A23D7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:melsoft_complete_clean_up_tool:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A6D30BBF-E50B-4C27-9A33-902D05F987AD",
              "versionEndIncluding": "1.06g",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:melsoft_em_software_development_kit:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "724C0E0B-5658-4040-A925-A07128EAD323",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:melsoft_iq_appportal:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8F2EA556-367B-4F32-99D2-C685742CCAEE",
              "versionEndIncluding": "1.17t",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:melsoft_navigator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0DC7353B-EFF7-432D-8F88-0D5EBBBBE4C0",
              "versionEndIncluding": "2.74c",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mi_configurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A661B972-912C-4DAA-9518-CC01E0EB1A81",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:motion_control_setting:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "12866465-10B2-4D45-B693-AE8C0EF34ADF",
              "versionEndIncluding": "1.005f",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:motorizer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5D82696C-937C-4B49-B748-006A6E836B03",
              "versionEndIncluding": "1.005f",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mr_configurator2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AEDAE974-4101-4B93-8DB5-8E93882AE3C5",
              "versionEndIncluding": "1.125f",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mt_works2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "57031F64-353E-403C-B7F8-0A145E70CBE7",
              "versionEndIncluding": "1.167z",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mtconnect_data_collector:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2561FAAC-19E7-48EE-AC80-8F9965EB2B2A",
              "versionEndIncluding": "1.1.4.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mx_component:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A0C9B5B3-D4F6-4E00-89B4-964516BB989B",
              "versionEndIncluding": "4.20w",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mx_mesinterface:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F84606A-A815-4A4C-9B7A-3A47449044D8",
              "versionEndIncluding": "1.21x",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mx_mesinterface-r:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C3CBAD07-E3E5-45C3-9208-B2F891D879F3",
              "versionEndIncluding": "1.12n",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mx_sheet:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EA891D85-4E28-4AA6-8393-5EC58C4BD923",
              "versionEndIncluding": "2.15r",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:position_board_utility_2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F4AC335D-3FF8-42A6-9567-023248CF7256",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:px_developer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "445EF081-A7BB-4568-850F-00CF58060D62",
              "versionEndIncluding": "1.53f",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:rt_toolbox2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5BD4EC4A-ACF7-45F2-893D-569B4F8F8909",
              "versionEndIncluding": "3.73b",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:rt_toolbox3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "779B0C13-D3DD-4D27-B18B-C0119B7BC5CB",
              "versionEndIncluding": "1.82l",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:setting\\/monitoring_tools_for_the_c_controller_module:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "85CBC7FE-6EF9-4DA5-8128-849233A8DC72",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:slmp_data_collector:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8814A8BA-AA54-4270-AAB1-679D0881D715",
              "versionEndIncluding": "1.04e",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_designer3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "45AFD554-F595-4B11-92DC-5655E8203C76",
              "versionEndIncluding": "1.241b",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:got1000_series_gt10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "70B37C4A-147A-4A7D-8F29-E2C366B54D68",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:got1000_series_gt11:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2AB71211-39CF-4AB7-8D7A-B6FC5C2A9FBC",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:got1000_series_gt12:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8E639243-577F-4787-8724-C1FEC886631D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:got1000_series_gt14:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D3BD1AB4-3A3D-46CD-B613-3E3613AAA273",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:got1000_series_gt15:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "29141984-191A-4A36-996D-9B60830CEA60",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:got1000_series_gt16:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "647842FC-AC89-462E-9856-3BB1E469CB52",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:got1000_series_gt21:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4EFBF467-8492-4CFB-8669-424A71B3CBAF",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:got1000_series_gt23:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1379891B-B1EC-433F-918B-8E9A4FBC0352",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:got1000_series_gt25:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5ADE2CDE-AB27-42DD-B4C0-1F4B2F55FE88",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:got1000_series_gt27:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9AD87755-DECB-4007-970F-A082EE983EB6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:network_interface_board_cc-link_ver.2_utility_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5162D96A-EFDD-4679-B9A1-76CDAF00CA58",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:network_interface_board_cc-link_ver.2_utility:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "43223F6D-B64C-49D7-8A04-DDB09B6D698E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:network_interface_board_cc_ie_control_utility_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0FF03D46-5539-432E-B67B-1D4494D3BBD6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:network_interface_board_cc_ie_control_utility:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D8ABB436-86C7-49BB-B95B-FD61BE60BAD5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:network_interface_board_cc_ie_field_utility_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "95873A25-2480-45F1-8FE3-D190AE9A824B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:network_interface_board_cc_ie_field_utility:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8A756E0D-EB80-4601-B07A-4F5ECD8D424F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:network_interface_board_mneth_utility_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "64CEB2D6-0113-47E9-A238-373472907CE5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:network_interface_board_mneth_utility:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "03EAB2BF-B0EF-4899-BF6D-3C0975462178",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Multiple Mitsubishi Electric Factory Automation engineering software products have a malicious code execution vulnerability. A malicious attacker could use this vulnerability to obtain information, modify information, and cause a denial-of-service condition."
    },
    {
      "lang": "es",
      "value": "diversos productos de software de ingenier\u00eda de Mitsubishi Electric Factory Automation presentan una vulnerabilidad de ejecuci\u00f3n de c\u00f3digo malicioso. Un atacante malicioso podr\u00eda usar esta vulnerabilidad para obtener informaci\u00f3n, modificar informaci\u00f3n y causar una condici\u00f3n de denegaci\u00f3n de servicio"
    }
  ],
  "id": "CVE-2020-14521",
  "lastModified": "2024-11-21T05:03:26.950",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 7.5,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.3,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.6,
        "impactScore": 6.0,
        "source": "ics-cert@hq.dhs.gov",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-02-11T18:15:08.513",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-04"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-007_en.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-04"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-007_en.pdf"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-428"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-276"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-11-25 00:15
Modified
2024-11-21 06:59
Summary
Use of Hard-coded Password vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.090U and GT Designer3 Version1 (GOT2000) versions from 1.122C to 1.290C allows an unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users may view programs and project files or execute programs illegally.
Impacted products



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A868567B-2BAA-45AE-AEC9-3AFEF2361297",
              "versionEndIncluding": "1.011m",
              "versionStartIncluding": "1.000a",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "56BD062B-0D41-42E2-B9EF-B7FBB514CFF9",
              "versionEndIncluding": "1.086q",
              "versionStartIncluding": "1.015r",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C7C6A654-1B83-4743-8DDE-B8C5AA5C4D2A",
              "versionStartIncluding": "1.087r",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Use of Hard-coded Password vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.090U and GT Designer3 Version1 (GOT2000) versions from 1.122C to 1.290C allows an unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users may view programs and project files or execute programs illegally."
    },
    {
      "lang": "es",
      "value": "El uso de la vulnerabilidad de contrase\u00f1a codificada en las versiones Mitsubishi Electric GX Works3 de 1.000A a 1.090U y GT Designer3 Versi\u00f3n1 (GOT2000) de 1.122C a 1.290C permite que un atacante no autenticado revele informaci\u00f3n sensible. Como resultado, los usuarios no autenticados pueden ver programas y archivos de proyectos o ejecutar programas ilegalmente."
    }
  ],
  "id": "CVE-2022-29825",
  "lastModified": "2024-11-21T06:59:45.647",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "LOCAL",
          "availabilityImpact": "NONE",
          "baseScore": 5.6,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.1,
        "impactScore": 4.0,
        "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-11-25T00:15:10.000",
  "references": [
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://jvn.jp/vu/JVNVU97244961/index.html"
    },
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"
    },
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://jvn.jp/vu/JVNVU97244961/index.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
    }
  ],
  "sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-259"
        }
      ],
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-798"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-11-25 00:15
Modified
2024-11-21 06:59
Summary
Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers may view programs and project files or execute programs illegally.
Impacted products



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A868567B-2BAA-45AE-AEC9-3AFEF2361297",
              "versionEndIncluding": "1.011m",
              "versionStartIncluding": "1.000a",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "56BD062B-0D41-42E2-B9EF-B7FBB514CFF9",
              "versionEndIncluding": "1.086q",
              "versionStartIncluding": "1.015r",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C7C6A654-1B83-4743-8DDE-B8C5AA5C4D2A",
              "versionStartIncluding": "1.087r",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers may view programs and project files or execute programs illegally."
    },
    {
      "lang": "es",
      "value": "El uso de una vulnerabilidad de clave criptogr\u00e1fica codificada en las versiones 1.000A y posteriores de Mitsubishi Electric GX Works3 permite que un atacante remoto no autenticado revele informaci\u00f3n sensible. Como resultado, los atacantes no autenticados pueden ver programas y archivos de proyectos o ejecutar programas ilegalmente."
    }
  ],
  "id": "CVE-2022-29827",
  "lastModified": "2024-11-21T06:59:45.917",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 6.8,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.2,
        "impactScore": 4.0,
        "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-11-25T00:15:10.157",
  "references": [
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://jvn.jp/vu/JVNVU97244961/index.html"
    },
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"
    },
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://jvn.jp/vu/JVNVU97244961/index.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
    }
  ],
  "sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-321"
        }
      ],
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-798"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-11-25 00:15
Modified
2024-11-21 06:59
Summary
Insufficiently Protected Credentials vulnerability in Mitsubishi Electric Corporation GX Works3 versions 1.015R and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users could access to MELSEC safety CPU modules illgally.
Impacted products



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "56BD062B-0D41-42E2-B9EF-B7FBB514CFF9",
              "versionEndIncluding": "1.086q",
              "versionStartIncluding": "1.015r",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C7C6A654-1B83-4743-8DDE-B8C5AA5C4D2A",
              "versionStartIncluding": "1.087r",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Insufficiently Protected Credentials vulnerability in Mitsubishi Electric Corporation GX Works3 versions 1.015R and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users could access to MELSEC safety CPU modules illgally."
    },
    {
      "lang": "es",
      "value": "Vulnerabilidad de credenciales insuficientemente protegidas en Mitsubishi Electric Corporation GX Works3 versiones 1.015R y posteriores permite que un atacante remoto no autenticado revele informaci\u00f3n sensible. Como resultado, los usuarios no autenticados podr\u00edan acceder ilegalmente a los m\u00f3dulos de CPU de seguridad de MELSEC."
    }
  ],
  "id": "CVE-2022-29833",
  "lastModified": "2024-11-21T06:59:46.690",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 6.8,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:N/I:H/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.2,
        "impactScore": 4.0,
        "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-11-25T00:15:10.580",
  "references": [
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://jvn.jp/vu/JVNVU97244961"
    },
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"
    },
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://jvn.jp/vu/JVNVU97244961"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
    }
  ],
  "sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-522"
        }
      ],
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-522"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-07-02 16:15
Modified
2024-11-21 09:00
Summary
Improper privilege management in Jungo WinDriver before 12.2.0 allows local attackers to escalate privileges and execute arbitrary code.
Impacted products
Vendor Product Version
jungo windriver *
mitsubishielectric cpu_module_logging_configuration_tool *
mitsubishielectric cw_configurator *
mitsubishielectric data_transfer *
mitsubishielectric data_transfer_classic *
mitsubishielectric ezsocket *
mitsubishielectric fr_configurator_sw3 *
mitsubishielectric fr_configurator2 *
mitsubishielectric genesis64 *
mitsubishielectric gt_got1000 *
mitsubishielectric gt_got2000 *
mitsubishielectric gt_softgot1000 *
mitsubishielectric gt_softgot2000 *
mitsubishielectric gx_developer *
mitsubishielectric gx_logviewer *
mitsubishielectric gx_works2 *
mitsubishielectric gx_works3 *
mitsubishielectric iq_works *
mitsubishielectric mi_configurator *
mitsubishielectric mr_configurator *
mitsubishielectric mr_configurator2 *
mitsubishielectric mx_component *
mitsubishielectric mx_opc_server_da\/ua *
mitsubishielectric numerical_control_device_communication *
mitsubishielectric px_developer\/monitor_tool *
mitsubishielectric rt_toolbox3 *
mitsubishielectric rt_visualbox *
mitsubishielectric mrzjw3-mc2-utl_firmware *
mitsubishielectric mrzjw3-mc2-utl -
mitsubishielectric sw0dnc-mneth-b_firmware *
mitsubishielectric sw0dnc-mneth-b -
mitsubishielectric sw1dnc-ccbd2-b_firmware *
mitsubishielectric sw1dnc-ccbd2-b -
mitsubishielectric sw1dnc-ccief-j_firmware *
mitsubishielectric sw1dnc-ccief-j -
mitsubishielectric sw1dnc-ccief-b_firmware *
mitsubishielectric sw1dnc-ccief-b -
mitsubishielectric sw1dnc-mnetg-b_firmware *
mitsubishielectric sw1dnc-mnetg-b -
mitsubishielectric sw1dnc-qsccf-b_firmware *
mitsubishielectric sw1dnc-qsccf-b -
mitsubishielectric sw1dnd-emsdk-b_firmware *
mitsubishielectric sw1dnd-emsdk-b -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:jungo:windriver:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0B7C4DE4-D93B-4AA6-B98E-738E00DC5024",
              "versionEndExcluding": "12.2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:cpu_module_logging_configuration_tool:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "463EA623-0DC2-4287-A9AC-837CBDECF76C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:cw_configurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E798352C-E09B-4D18-B3A8-CFCDE0AD3675",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:data_transfer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "21CC610A-0561-46A1-9077-D01D5C3F1A8F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:data_transfer_classic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B36ABBC-DB27-44D1-B844-00DFC3BBF043",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:ezsocket:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C6E4BC24-6583-4791-9ED9-D2D675187DCD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:fr_configurator_sw3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D236ABC2-93E4-4428-B949-7E17945E4D98",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:fr_configurator2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CED78B28-BBBF-4869-BC1C-F0789867FB4C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:genesis64:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C79890F-0B41-4855-84EE-78D5896C87A1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_got1000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4400D339-BB12-414A-B891-B6105D7FCA39",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_got2000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6871A74E-8B92-4892-970F-757F404590CB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_softgot1000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "03DE7DE4-DC4B-40F3-BB22-B8E524081942",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_softgot2000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9F8037F0-C124-4EFB-AEA1-89441975D36F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_developer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9C37E74B-DA76-4E59-953E-C50D0D75804A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_logviewer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B0B195E2-6076-487C-899F-A40B886BA556",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6C4E7C31-D08D-487F-B7FF-9502783FFDB9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F4AEDEEE-5070-41E2-B4DC-6DE8456BC028",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:iq_works:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7097AFD0-5A8C-4C62-AAF7-16FB71DE210C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mi_configurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A661B972-912C-4DAA-9518-CC01E0EB1A81",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mr_configurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "76C1D9F0-48A8-4193-A781-B19ACE1B0B4B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mr_configurator2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9FB81A97-4BE8-4570-914F-304F38968613",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mx_component:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CE14782A-4AD2-4633-8A3A-D81D5C434046",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mx_opc_server_da\\/ua:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A1BABCB-EDD7-4B1D-AE49-77DD1A3CCB1C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:numerical_control_device_communication:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4F89B350-B20F-45A8-8809-E9776C319591",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:px_developer\\/monitor_tool:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2B10E09F-84F3-42E3-9B8D-DE309ED4A4B4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:rt_toolbox3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7C12A1AA-66F0-452F-9B75-562F4A979CBD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:rt_visualbox:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "33A13944-145E-453E-A409-BE4A984619AA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:mrzjw3-mc2-utl_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A10A8E35-923F-483B-A924-441B78FFCF6D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:mrzjw3-mc2-utl:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "938DDBFF-A0CC-4311-9F30-08ABDBB67742",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw0dnc-mneth-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB49716D-8E0B-4E4C-B206-104BB64F6301",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw0dnc-mneth-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C8B0237-9A91-4954-AFBE-E661467D842A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-ccbd2-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B3B0B5A-27F2-4E08-8B75-1EAAC4DC840D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-ccbd2-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0B80AF0C-EFED-4CA0-B990-0ADA6F1D0AEE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-ccief-j_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B4348FF-8691-4832-9103-F46282924299",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-ccief-j:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "07737420-567D-49CC-9A9E-555038DFF0AA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-ccief-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5D3A5D57-DB2C-429F-BB3F-8EB7F4767E1D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-ccief-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FD4CA442-BC30-407E-851E-E03037E75E8D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-mnetg-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9826969F-D449-4032-8A0B-050D7CC3B1AE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-mnetg-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "858F9CAA-E6D3-4F1D-923D-ED9E05C3AC54",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-qsccf-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "61A13AD1-22F7-4FFD-BCB7-A4FDAF2BA659",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-qsccf-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "009853DA-ACAE-4928-AE90-090A3739BD39",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnd-emsdk-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "476C7885-89D2-4A6C-94FE-E06B55A23E37",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnd-emsdk-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9DF10CF6-1C1D-4768-A349-1AEFD26F491A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Improper privilege management in Jungo WinDriver before 12.2.0 allows local attackers to escalate privileges and execute arbitrary code."
    },
    {
      "lang": "es",
      "value": "La gesti\u00f3n inadecuada de privilegios en Jungo WinDriver anterior a 12.2.0 permite a atacantes locales escalar privilegios y ejecutar c\u00f3digo arbitrario."
    }
  ],
  "id": "CVE-2024-25086",
  "lastModified": "2024-11-21T09:00:13.183",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-07-02T16:15:04.070",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Release Notes"
      ],
      "url": "https://jungo.com/windriver/versions/"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-04"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-001_en.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Release Notes"
      ],
      "url": "https://jungo.com/windriver/versions/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-04"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-001_en.pdf"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-94"
        },
        {
          "lang": "en",
          "value": "CWE-269"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-07-02 16:15
Modified
2024-11-21 09:00
Summary
Improper privilege management in Jungo WinDriver before 12.5.1 allows local attackers to escalate privileges and execute arbitrary code.
Impacted products
Vendor Product Version
jungo windriver *
mitsubishielectric cpu_module_logging_configuration_tool *
mitsubishielectric cw_configurator *
mitsubishielectric data_transfer *
mitsubishielectric data_transfer_classic *
mitsubishielectric ezsocket *
mitsubishielectric fr_configurator_sw3 *
mitsubishielectric fr_configurator2 *
mitsubishielectric genesis64 *
mitsubishielectric gt_got1000 *
mitsubishielectric gt_got2000 *
mitsubishielectric gt_softgot1000 *
mitsubishielectric gt_softgot2000 *
mitsubishielectric gx_developer *
mitsubishielectric gx_logviewer *
mitsubishielectric gx_works2 *
mitsubishielectric gx_works3 *
mitsubishielectric iq_works *
mitsubishielectric mi_configurator *
mitsubishielectric mr_configurator *
mitsubishielectric mr_configurator2 *
mitsubishielectric mx_component *
mitsubishielectric mx_opc_server_da\/ua *
mitsubishielectric numerical_control_device_communication *
mitsubishielectric px_developer\/monitor_tool *
mitsubishielectric rt_toolbox3 *
mitsubishielectric rt_visualbox *
mitsubishielectric mrzjw3-mc2-utl_firmware *
mitsubishielectric mrzjw3-mc2-utl -
mitsubishielectric sw0dnc-mneth-b_firmware *
mitsubishielectric sw0dnc-mneth-b -
mitsubishielectric sw1dnc-ccbd2-b_firmware *
mitsubishielectric sw1dnc-ccbd2-b -
mitsubishielectric sw1dnc-ccief-j_firmware *
mitsubishielectric sw1dnc-ccief-j -
mitsubishielectric sw1dnc-ccief-b_firmware *
mitsubishielectric sw1dnc-ccief-b -
mitsubishielectric sw1dnc-mnetg-b_firmware *
mitsubishielectric sw1dnc-mnetg-b -
mitsubishielectric sw1dnc-qsccf-b_firmware *
mitsubishielectric sw1dnc-qsccf-b -
mitsubishielectric sw1dnd-emsdk-b_firmware *
mitsubishielectric sw1dnd-emsdk-b -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:jungo:windriver:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CD5769FE-170B-4FCC-9A2E-B487C2DAFB16",
              "versionEndExcluding": "12.5.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:cpu_module_logging_configuration_tool:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "463EA623-0DC2-4287-A9AC-837CBDECF76C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:cw_configurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E798352C-E09B-4D18-B3A8-CFCDE0AD3675",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:data_transfer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "21CC610A-0561-46A1-9077-D01D5C3F1A8F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:data_transfer_classic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B36ABBC-DB27-44D1-B844-00DFC3BBF043",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:ezsocket:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C6E4BC24-6583-4791-9ED9-D2D675187DCD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:fr_configurator_sw3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D236ABC2-93E4-4428-B949-7E17945E4D98",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:fr_configurator2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CED78B28-BBBF-4869-BC1C-F0789867FB4C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:genesis64:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C79890F-0B41-4855-84EE-78D5896C87A1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_got1000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4400D339-BB12-414A-B891-B6105D7FCA39",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_got2000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6871A74E-8B92-4892-970F-757F404590CB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_softgot1000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "03DE7DE4-DC4B-40F3-BB22-B8E524081942",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_softgot2000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9F8037F0-C124-4EFB-AEA1-89441975D36F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_developer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9C37E74B-DA76-4E59-953E-C50D0D75804A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_logviewer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B0B195E2-6076-487C-899F-A40B886BA556",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6C4E7C31-D08D-487F-B7FF-9502783FFDB9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F4AEDEEE-5070-41E2-B4DC-6DE8456BC028",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:iq_works:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7097AFD0-5A8C-4C62-AAF7-16FB71DE210C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mi_configurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A661B972-912C-4DAA-9518-CC01E0EB1A81",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mr_configurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "76C1D9F0-48A8-4193-A781-B19ACE1B0B4B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mr_configurator2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9FB81A97-4BE8-4570-914F-304F38968613",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mx_component:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CE14782A-4AD2-4633-8A3A-D81D5C434046",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mx_opc_server_da\\/ua:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A1BABCB-EDD7-4B1D-AE49-77DD1A3CCB1C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:numerical_control_device_communication:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4F89B350-B20F-45A8-8809-E9776C319591",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:px_developer\\/monitor_tool:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2B10E09F-84F3-42E3-9B8D-DE309ED4A4B4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:rt_toolbox3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7C12A1AA-66F0-452F-9B75-562F4A979CBD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:rt_visualbox:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "33A13944-145E-453E-A409-BE4A984619AA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:mrzjw3-mc2-utl_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A10A8E35-923F-483B-A924-441B78FFCF6D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:mrzjw3-mc2-utl:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "938DDBFF-A0CC-4311-9F30-08ABDBB67742",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw0dnc-mneth-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB49716D-8E0B-4E4C-B206-104BB64F6301",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw0dnc-mneth-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C8B0237-9A91-4954-AFBE-E661467D842A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-ccbd2-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B3B0B5A-27F2-4E08-8B75-1EAAC4DC840D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-ccbd2-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0B80AF0C-EFED-4CA0-B990-0ADA6F1D0AEE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-ccief-j_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B4348FF-8691-4832-9103-F46282924299",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-ccief-j:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "07737420-567D-49CC-9A9E-555038DFF0AA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-ccief-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5D3A5D57-DB2C-429F-BB3F-8EB7F4767E1D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-ccief-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FD4CA442-BC30-407E-851E-E03037E75E8D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-mnetg-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9826969F-D449-4032-8A0B-050D7CC3B1AE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-mnetg-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "858F9CAA-E6D3-4F1D-923D-ED9E05C3AC54",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnc-qsccf-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "61A13AD1-22F7-4FFD-BCB7-A4FDAF2BA659",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnc-qsccf-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "009853DA-ACAE-4928-AE90-090A3739BD39",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mitsubishielectric:sw1dnd-emsdk-b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "476C7885-89D2-4A6C-94FE-E06B55A23E37",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mitsubishielectric:sw1dnd-emsdk-b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9DF10CF6-1C1D-4768-A349-1AEFD26F491A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Improper privilege management in Jungo WinDriver before 12.5.1 allows local attackers to escalate privileges and execute arbitrary code."
    },
    {
      "lang": "es",
      "value": "La gesti\u00f3n inadecuada de privilegios en Jungo WinDriver anterior a 12.5.1 permite a atacantes locales escalar privilegios y ejecutar c\u00f3digo arbitrario."
    }
  ],
  "id": "CVE-2024-25088",
  "lastModified": "2024-11-21T09:00:13.633",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-07-02T16:15:04.250",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Release Notes"
      ],
      "url": "https://jungo.com/windriver/versions/"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-04"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-001_en.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Release Notes"
      ],
      "url": "https://jungo.com/windriver/versions/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-04"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-001_en.pdf"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-269"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2020-06-30 11:15
Modified
2024-11-21 05:34
Summary
Mitsubishi Electoric FA Engineering Software (CPU Module Logging Configuration Tool Ver. 1.94Y and earlier, CW Configurator Ver. 1.010L and earlier, EM Software Development Kit (EM Configurator) Ver. 1.010L and earlier, GT Designer3 (GOT2000) Ver. 1.221F and earlier, GX LogViewer Ver. 1.96A and earlier, GX Works2 Ver. 1.586L and earlier, GX Works3 Ver. 1.058L and earlier, M_CommDTM-HART Ver. 1.00A, M_CommDTM-IO-Link Ver. 1.02C and earlier, MELFA-Works Ver. 4.3 and earlier, MELSEC-L Flexible High-Speed I/O Control Module Configuration Tool Ver.1.004E and earlier, MELSOFT FieldDeviceConfigurator Ver. 1.03D and earlier, MELSOFT iQ AppPortal Ver. 1.11M and earlier, MELSOFT Navigator Ver. 2.58L and earlier, MI Configurator Ver. 1.003D and earlier, Motion Control Setting Ver. 1.005F and earlier, MR Configurator2 Ver. 1.72A and earlier, MT Works2 Ver. 1.156N and earlier, RT ToolBox2 Ver. 3.72A and earlier, and RT ToolBox3 Ver. 1.50C and earlier) allows an attacker to conduct XML External Entity (XXE) attacks via unspecified vectors.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:cpu_module_logging_configuration_tool:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5AA4BCF9-CE1B-4A53-BBBD-396FE7D8D410",
              "versionEndIncluding": "1.94y",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:cw_configurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "892E3CDC-AFC4-4EF1-AF46-3F161603DDB1",
              "versionEndIncluding": "1.010l",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:em_configurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD8B6AFD-17BE-4657-9F55-B0CA52E2578A",
              "versionEndIncluding": "1.010l",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gt_designer3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "567CE406-0FCE-44DC-B210-1E54EDB6FE11",
              "versionEndIncluding": "1.221f",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_logviewer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "591B76E1-665F-4473-8A65-B8549B61807F",
              "versionEndIncluding": "1.100e",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7CCB1E6D-333D-458E-AE2D-974E16195811",
              "versionEndIncluding": "1.590q",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "20F14A8B-E42D-4621-8BCC-A6D28A8A0D7A",
              "versionEndIncluding": "1.060n",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:m_commdtm-hart:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "35D76E9B-394E-47A1-B6F1-4854909A8D59",
              "versionEndIncluding": "1.01b",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:m_commdtm-io-link:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "37B4823F-E257-4CFF-A20B-FAB4A60D49D9",
              "versionEndIncluding": "1.03d",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:melfa-works:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4116C452-19C3-4F48-8A05-864BD884BDD0",
              "versionEndIncluding": "4.4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:melsec-l_flexible_high-speed_i\\/o_control_module_configuration_tool:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BB41FBDD-2785-4012-AB84-2B1F947E9512",
              "versionEndIncluding": "1.005f",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:melsoft_fielddeviceconfigurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6DBBC676-19E1-4780-8D23-6888884E67A4",
              "versionEndIncluding": "1.04e",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:melsoft_iq_appportal:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "56B1A257-F1C6-4213-92A0-7476E3EB6207",
              "versionEndIncluding": "1.14q",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:melsoft_navigator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "76A6CCE9-ACB8-4A24-A4E5-0F8DCBC4475B",
              "versionEndIncluding": "2.62q",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mi_configurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DA012067-3CF9-46E8-9C5D-C64D92C2574D",
              "versionEndIncluding": "1.004e",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:motion_control_setting:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "19CEBFB8-E23E-4ABB-9337-221D6749D456",
              "versionEndIncluding": "1.006g",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mr_configurator2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6998E84B-0EFC-4ACB-BFC6-FFC1A675F1B3",
              "versionEndIncluding": "1.100e",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:mt_works2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0303271B-F016-4D0E-A862-313A31B8CD60",
              "versionEndIncluding": "1.160s",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:rt_toolbox2:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5BD4EC4A-ACF7-45F2-893D-569B4F8F8909",
              "versionEndIncluding": "3.73b",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mitsubishielectric:rt_toolbox3:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5E66C5F1-23BF-42F9-8A25-FE8A7E66B07D",
              "versionEndIncluding": "1.60n",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Mitsubishi Electoric FA Engineering Software (CPU Module Logging Configuration Tool Ver. 1.94Y and earlier, CW Configurator Ver. 1.010L and earlier, EM Software Development Kit (EM Configurator) Ver. 1.010L and earlier, GT Designer3 (GOT2000) Ver. 1.221F and earlier, GX LogViewer Ver. 1.96A and earlier, GX Works2 Ver. 1.586L and earlier, GX Works3 Ver. 1.058L and earlier, M_CommDTM-HART Ver. 1.00A, M_CommDTM-IO-Link Ver. 1.02C and earlier, MELFA-Works Ver. 4.3 and earlier, MELSEC-L Flexible High-Speed I/O Control Module Configuration Tool Ver.1.004E and earlier, MELSOFT FieldDeviceConfigurator Ver. 1.03D and earlier, MELSOFT iQ AppPortal Ver. 1.11M and earlier, MELSOFT Navigator Ver. 2.58L and earlier, MI Configurator Ver. 1.003D and earlier, Motion Control Setting Ver. 1.005F and earlier, MR Configurator2 Ver. 1.72A and earlier, MT Works2 Ver. 1.156N and earlier, RT ToolBox2 Ver. 3.72A and earlier, and RT ToolBox3 Ver. 1.50C and earlier) allows an attacker to conduct XML External Entity (XXE) attacks via unspecified vectors."
    },
    {
      "lang": "es",
      "value": "Mitsubishi Electoric FA Engineering Software (CPU Module Logging Configuration Tool Versiones 1.94Y y anteriores, Configurador CW Versiones 1.010L y anteriores, EM Software Development Kit (Configurador EM) Versiones 1.010L y anteriores, GT Designer3 (GOT2000) Versiones 1.221 F y anteriores, GX LogViewer Versiones 1.96A y anteriores, GX Works2 Versiones 1.586L y anteriores, GX Works3 Versiones 1.058L y anteriores, M_CommDTM-HART Versiones 1.00A, M_CommDTM-IO-Link Versiones 1.02C y anteriores , MELFA-Works Versiones 4.3 y anteriores, MELSEC-L Flexible High-Speed I/O Control Module Configuration Tool Versiones 1.004E y anteriores, MELSOFT FieldDeviceConfigurator Versiones 1.03D y anteriores, MELSOFT iQ AppPortal Versiones 1.11M y anteriores, MELSOFT Navigator Versiones 2.58L y anteriores, MI Configurator Versiones 1.003D y anteriores, Motion Control Setting Versiones 1.005F y anteriores, MR Configurator2 Versiones 1.72A y anteriores, MT Works2 Versiones 1.156N y anteriores, RT ToolBox2 Versiones 3.72A y anteriores, y RT ToolBox3 Versiones 1.50C y anteriores, permite a un atacante conducir ataques de tipo XML External Entity (XXE) por medio de vectores no especificados"
    }
  ],
  "id": "CVE-2020-5602",
  "lastModified": "2024-11-21T05:34:20.697",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 5.0,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2020-06-30T11:15:11.333",
  "references": [
    {
      "source": "vultures@jpcert.or.jp",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://jvn.jp/en/vu/JVNVU90307594/index.html"
    },
    {
      "source": "vultures@jpcert.or.jp",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-004_en.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://jvn.jp/en/vu/JVNVU90307594/index.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-004_en.pdf"
    }
  ],
  "sourceIdentifier": "vultures@jpcert.or.jp",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-611"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}