Search criteria
3 vulnerabilities found for gxp2135_firmware by grandstream
FKIE_CVE-2024-32937
Vulnerability from fkie_nvd - Published: 2024-07-03 14:15 - Updated: 2025-11-04 18:16
Severity ?
8.1 (High) - CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
An os command injection vulnerability exists in the CWMP SelfDefinedTimeZone functionality of Grandstream GXP2135 1.0.9.129, 1.0.11.74 and 1.0.11.79. A specially crafted network packet can lead to arbitrary command execution. An attacker can send a sequence of malicious packets to trigger this vulnerability.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| grandstream | gxp2135_firmware | 1.0.9.129 | |
| grandstream | gxp2135_firmware | 1.0.11.74 | |
| grandstream | gxp2135_firmware | 1.0.11.79 | |
| grandstream | gxp2135 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:grandstream:gxp2135_firmware:1.0.9.129:*:*:*:*:*:*:*",
"matchCriteriaId": "8994D143-ED40-4470-8291-2C86B52A448F",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:grandstream:gxp2135_firmware:1.0.11.74:*:*:*:*:*:*:*",
"matchCriteriaId": "E1ACAB82-1736-4703-B337-46339C5A02DA",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:grandstream:gxp2135_firmware:1.0.11.79:*:*:*:*:*:*:*",
"matchCriteriaId": "44ADA86F-F73D-4C22-9C79-BF0DC0D60BAA",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:grandstream:gxp2135:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7FA43CFF-B138-47D7-A030-22CBE4E1F3D2",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An os command injection vulnerability exists in the CWMP SelfDefinedTimeZone functionality of Grandstream GXP2135 1.0.9.129, 1.0.11.74 and 1.0.11.79. A specially crafted network packet can lead to arbitrary command execution. An attacker can send a sequence of malicious packets to trigger this vulnerability."
},
{
"lang": "es",
"value": "Existe una vulnerabilidad de inyecci\u00f3n de comandos del sistema operativo en la funcionalidad CWMP SelfDefinedTimeZone de Grandstream GXP2135 1.0.9.129, 1.0.11.74 y 1.0.11.79. Un paquete de red especialmente manipulado puede provocar la ejecuci\u00f3n de comandos arbitrarios. Un atacante puede enviar una secuencia de paquetes maliciosos para desencadenar esta vulnerabilidad."
}
],
"id": "CVE-2024-32937",
"lastModified": "2025-11-04T18:16:20.503",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.2,
"impactScore": 5.9,
"source": "talos-cna@cisco.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2024-07-03T14:15:05.340",
"references": [
{
"source": "talos-cna@cisco.com",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2024-1978"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2024-1978"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2024-1978"
}
],
"sourceIdentifier": "talos-cna@cisco.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-78"
}
],
"source": "talos-cna@cisco.com",
"type": "Secondary"
}
]
}
CVE-2024-32937 (GCVE-0-2024-32937)
Vulnerability from cvelistv5 – Published: 2024-07-03 14:05 – Updated: 2025-11-04 17:20
VLAI?
Summary
An os command injection vulnerability exists in the CWMP SelfDefinedTimeZone functionality of Grandstream GXP2135 1.0.9.129, 1.0.11.74 and 1.0.11.79. A specially crafted network packet can lead to arbitrary command execution. An attacker can send a sequence of malicious packets to trigger this vulnerability.
Severity ?
8.1 (High)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Grandstream | GXP2135 |
Affected:
1.0.11.74
Affected: 1.0.11.79 Affected: 1.0.9.129 |
Credits
Discovered by Matthew Bernath of Cisco Talos.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:grandstream:gxp2135_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "gxp2135_firmware",
"vendor": "grandstream",
"versions": [
{
"status": "affected",
"version": "1.0.11.74"
},
{
"status": "affected",
"version": "1.0.11.79"
},
{
"status": "affected",
"version": "1.0.9.129"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-32937",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-03T14:16:57.228461Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-03T14:59:05.703Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-04T17:20:20.384Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2024-1978",
"tags": [
"x_transferred"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2024-1978"
},
{
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2024-1978"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "GXP2135",
"vendor": "Grandstream",
"versions": [
{
"status": "affected",
"version": "1.0.11.74"
},
{
"status": "affected",
"version": "1.0.11.79"
},
{
"status": "affected",
"version": "1.0.9.129"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Discovered by Matthew Bernath of Cisco Talos."
}
],
"descriptions": [
{
"lang": "en",
"value": "An os command injection vulnerability exists in the CWMP SelfDefinedTimeZone functionality of Grandstream GXP2135 1.0.9.129, 1.0.11.74 and 1.0.11.79. A specially crafted network packet can lead to arbitrary command execution. An attacker can send a sequence of malicious packets to trigger this vulnerability."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-03T17:00:11.294Z",
"orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"shortName": "talos"
},
"references": [
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2024-1978",
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2024-1978"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"assignerShortName": "talos",
"cveId": "CVE-2024-32937",
"datePublished": "2024-07-03T14:05:35.575Z",
"dateReserved": "2024-04-19T20:26:32.967Z",
"dateUpdated": "2025-11-04T17:20:20.384Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2024-32937 (GCVE-0-2024-32937)
Vulnerability from nvd – Published: 2024-07-03 14:05 – Updated: 2025-11-04 17:20
VLAI?
Summary
An os command injection vulnerability exists in the CWMP SelfDefinedTimeZone functionality of Grandstream GXP2135 1.0.9.129, 1.0.11.74 and 1.0.11.79. A specially crafted network packet can lead to arbitrary command execution. An attacker can send a sequence of malicious packets to trigger this vulnerability.
Severity ?
8.1 (High)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Grandstream | GXP2135 |
Affected:
1.0.11.74
Affected: 1.0.11.79 Affected: 1.0.9.129 |
Credits
Discovered by Matthew Bernath of Cisco Talos.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:grandstream:gxp2135_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "gxp2135_firmware",
"vendor": "grandstream",
"versions": [
{
"status": "affected",
"version": "1.0.11.74"
},
{
"status": "affected",
"version": "1.0.11.79"
},
{
"status": "affected",
"version": "1.0.9.129"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-32937",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-03T14:16:57.228461Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-03T14:59:05.703Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-04T17:20:20.384Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2024-1978",
"tags": [
"x_transferred"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2024-1978"
},
{
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2024-1978"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "GXP2135",
"vendor": "Grandstream",
"versions": [
{
"status": "affected",
"version": "1.0.11.74"
},
{
"status": "affected",
"version": "1.0.11.79"
},
{
"status": "affected",
"version": "1.0.9.129"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Discovered by Matthew Bernath of Cisco Talos."
}
],
"descriptions": [
{
"lang": "en",
"value": "An os command injection vulnerability exists in the CWMP SelfDefinedTimeZone functionality of Grandstream GXP2135 1.0.9.129, 1.0.11.74 and 1.0.11.79. A specially crafted network packet can lead to arbitrary command execution. An attacker can send a sequence of malicious packets to trigger this vulnerability."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-03T17:00:11.294Z",
"orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"shortName": "talos"
},
"references": [
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2024-1978",
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2024-1978"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"assignerShortName": "talos",
"cveId": "CVE-2024-32937",
"datePublished": "2024-07-03T14:05:35.575Z",
"dateReserved": "2024-04-19T20:26:32.967Z",
"dateUpdated": "2025-11-04T17:20:20.384Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}