Search criteria
6 vulnerabilities found for hospital_manager_backend_services by vertikalsystems
FKIE_CVE-2025-54459
Vulnerability from fkie_nvd - Published: 2025-10-29 22:15 - Updated: 2025-11-06 19:21
Severity ?
Summary
Prior to September 19, 2025, the Hospital Manager Backend Services exposed the ASP.NET tracing endpoint /trace.axd without authentication, allowing a remote attacker to obtain live request traces and sensitive information such as request metadata, session identifiers, authorization headers, server variables, and internal file paths.
References
| URL | Tags | ||
|---|---|---|---|
| ics-cert@hq.dhs.gov | https://www.cisa.gov/news-events/ics-medical-advisories/icsma-25-301-01 | Mitigation, Third Party Advisory, US Government Resource |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| vertikalsystems | hospital_manager_backend_services | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:vertikalsystems:hospital_manager_backend_services:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F9A856B2-70B6-4025-B853-B04C9080D91D",
"versionEndIncluding": "2025-09-19",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Prior to September 19, 2025, the Hospital Manager Backend Services exposed the ASP.NET tracing endpoint /trace.axd without authentication, allowing a remote attacker to obtain live request traces and sensitive information such as request metadata, session identifiers, authorization headers, server variables, and internal file paths."
}
],
"id": "CVE-2025-54459",
"lastModified": "2025-11-06T19:21:29.023",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
}
]
},
"published": "2025-10-29T22:15:40.200",
"references": [
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Mitigation",
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-25-301-01"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-497"
}
],
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
}
]
}
FKIE_CVE-2025-61959
Vulnerability from fkie_nvd - Published: 2025-10-29 22:15 - Updated: 2025-11-06 19:20
Severity ?
Summary
Prior to September 19, 2025, the Hospital Manager Backend Services returned verbose ASP.NET error pages for invalid WebResource.axd requests, disclosing framework and ASP.NET version information, stack traces, internal paths, and the insecure configuration 'customErrors mode="Off"', which could have facilitated reconnaissance by unauthenticated attackers.
References
| URL | Tags | ||
|---|---|---|---|
| ics-cert@hq.dhs.gov | https://www.cisa.gov/news-events/ics-medical-advisories/icsma-25-301-01 | Mitigation, Third Party Advisory, US Government Resource | |
| ics-cert@hq.dhs.gov | https://www.vertikalsystems.com/en/products/pm/contact.php | Product |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| vertikalsystems | hospital_manager_backend_services | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:vertikalsystems:hospital_manager_backend_services:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F9A856B2-70B6-4025-B853-B04C9080D91D",
"versionEndIncluding": "2025-09-19",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Prior to September 19, 2025, the Hospital Manager Backend Services returned verbose ASP.NET error pages for invalid WebResource.axd requests, disclosing framework and ASP.NET version information, stack traces, internal paths, and the insecure configuration \u0027customErrors mode=\"Off\"\u0027, which could have facilitated reconnaissance by unauthenticated attackers."
}
],
"id": "CVE-2025-61959",
"lastModified": "2025-11-06T19:20:34.117",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 1.4,
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
}
]
},
"published": "2025-10-29T22:15:40.733",
"references": [
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Mitigation",
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-25-301-01"
},
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Product"
],
"url": "https://www.vertikalsystems.com/en/products/pm/contact.php"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-209"
}
],
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
}
]
}
CVE-2025-61959 (GCVE-0-2025-61959)
Vulnerability from cvelistv5 – Published: 2025-10-29 21:54 – Updated: 2025-10-30 20:32
VLAI?
Title
Vertikal Systems Hospital Manager Backend Services Generation of Error Message Containing Sensitive Information
Summary
Prior to September 19, 2025, the Hospital Manager Backend Services returned verbose ASP.NET error pages for invalid WebResource.axd requests, disclosing framework and ASP.NET version information, stack traces, internal paths, and the insecure configuration 'customErrors mode="Off"', which could have facilitated reconnaissance by unauthenticated attackers.
Severity ?
5.3 (Medium)
CWE
- CWE-209 - Generation of Error Message Containing Sensitive Information
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Vertikal Systems | Hospital Manager Backend Services |
Affected:
0 , ≤ September 19, 2025
(custom)
|
Credits
Pundhapat Sichamnong reported these vulnerabilities to CISA.
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-61959",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-30T20:32:04.844198Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-30T20:32:15.522Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Hospital Manager Backend Services",
"vendor": "Vertikal Systems",
"versions": [
{
"lessThanOrEqual": "September 19, 2025",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:vertikal_systems:hospital_manager_backend_services:*:*:*:*:*:*:*:*",
"versionEndIncluding": "september_19,_2025",
"versionStartIncluding": "0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Pundhapat Sichamnong reported these vulnerabilities to CISA."
}
],
"datePublic": "2025-10-28T17:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003ePrior to September 19, 2025, the Hospital Manager Backend Services returned verbose ASP.NET error pages for invalid WebResource.axd requests, disclosing framework and ASP.NET version information, stack traces, internal paths, and the insecure configuration \u0027customErrors mode=\"Off\"\u0027, which could have facilitated reconnaissance by unauthenticated attackers.\u003c/span\u003e\n\n\u003c/span\u003e"
}
],
"value": "Prior to September 19, 2025, the Hospital Manager Backend Services returned verbose ASP.NET error pages for invalid WebResource.axd requests, disclosing framework and ASP.NET version information, stack traces, internal paths, and the insecure configuration \u0027customErrors mode=\"Off\"\u0027, which could have facilitated reconnaissance by unauthenticated attackers."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-209",
"description": "CWE-209 Generation of Error Message Containing Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-29T21:54:51.533Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-25-301-01"
},
{
"url": "https://www.vertikalsystems.com/en/products/pm/contact.php"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eVertikal Systems fixed these vulnerabilities by September 19, 2025. For more information, users should contact \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.vertikalsystems.com/en/products/pm/contact.php\"\u003eVertikal Systems support\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;for assistance.\u003c/span\u003e\n\n\u003cbr\u003e"
}
],
"value": "Vertikal Systems fixed these vulnerabilities by September 19, 2025. For more information, users should contact Vertikal Systems support https://www.vertikalsystems.com/en/products/pm/contact.php \u00a0for assistance."
}
],
"source": {
"advisory": "ICSMA-25-301-01",
"discovery": "EXTERNAL"
},
"title": "Vertikal Systems Hospital Manager Backend Services Generation of Error Message Containing Sensitive Information",
"x_generator": {
"engine": "Vulnogram 0.4.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2025-61959",
"datePublished": "2025-10-29T21:54:51.533Z",
"dateReserved": "2025-10-08T22:13:45.428Z",
"dateUpdated": "2025-10-30T20:32:15.522Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-54459 (GCVE-0-2025-54459)
Vulnerability from cvelistv5 – Published: 2025-10-29 21:51 – Updated: 2025-10-30 20:31
VLAI?
Title
Vertikal Systems Hospital Manager Backend Services Exposure of Sensitive System Information to an Unauthorized Control Sphere
Summary
Prior to September 19, 2025, the Hospital Manager Backend Services exposed the ASP.NET tracing endpoint /trace.axd without authentication, allowing a remote attacker to obtain live request traces and sensitive information such as request metadata, session identifiers, authorization headers, server variables, and internal file paths.
Severity ?
CWE
- CWE-497 - Exposure of Sensitive System Information to an Unauthorized Control Sphere
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Vertikal Systems | Hospital Manager Backend Services |
Affected:
0 , ≤ September 19, 2025
(custom)
|
Credits
Pundhapat Sichamnong reported these vulnerabilities to CISA.
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-54459",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-30T20:31:25.447134Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-30T20:31:36.976Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Hospital Manager Backend Services",
"vendor": "Vertikal Systems",
"versions": [
{
"lessThanOrEqual": "September 19, 2025",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:vertikal_systems:hospital_manager_backend_services:*:*:*:*:*:*:*:*",
"versionEndIncluding": "september_19,_2025",
"versionStartIncluding": "0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Pundhapat Sichamnong reported these vulnerabilities to CISA."
}
],
"datePublic": "2025-10-28T17:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003ePrior to September 19, 2025, the Hospital Manager Backend Services exposed the ASP.NET tracing endpoint /trace.axd without authentication, allowing a remote attacker to obtain live request traces and sensitive information such as request metadata, session identifiers, authorization headers, server variables, and internal file paths.\u003c/span\u003e"
}
],
"value": "Prior to September 19, 2025, the Hospital Manager Backend Services exposed the ASP.NET tracing endpoint /trace.axd without authentication, allowing a remote attacker to obtain live request traces and sensitive information such as request metadata, session identifiers, authorization headers, server variables, and internal file paths."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-497",
"description": "CWE-497 Exposure of Sensitive System Information to an Unauthorized Control Sphere",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-29T21:51:34.082Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-25-301-01"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eVertikal Systems fixed these vulnerabilities by September 19, 2025. For more information, users should contact \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.vertikalsystems.com/en/products/pm/contact.php\"\u003eVertikal Systems support\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;for assistance.\u003c/span\u003e\n\n\u003cbr\u003e"
}
],
"value": "Vertikal Systems fixed these vulnerabilities by September 19, 2025. For more information, users should contact Vertikal Systems support https://www.vertikalsystems.com/en/products/pm/contact.php \u00a0for assistance."
}
],
"source": {
"advisory": "ICSMA-25-301-01",
"discovery": "EXTERNAL"
},
"title": "Vertikal Systems Hospital Manager Backend Services Exposure of Sensitive System Information to an Unauthorized Control Sphere",
"x_generator": {
"engine": "Vulnogram 0.4.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2025-54459",
"datePublished": "2025-10-29T21:51:34.082Z",
"dateReserved": "2025-10-08T22:13:45.410Z",
"dateUpdated": "2025-10-30T20:31:36.976Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-61959 (GCVE-0-2025-61959)
Vulnerability from nvd – Published: 2025-10-29 21:54 – Updated: 2025-10-30 20:32
VLAI?
Title
Vertikal Systems Hospital Manager Backend Services Generation of Error Message Containing Sensitive Information
Summary
Prior to September 19, 2025, the Hospital Manager Backend Services returned verbose ASP.NET error pages for invalid WebResource.axd requests, disclosing framework and ASP.NET version information, stack traces, internal paths, and the insecure configuration 'customErrors mode="Off"', which could have facilitated reconnaissance by unauthenticated attackers.
Severity ?
5.3 (Medium)
CWE
- CWE-209 - Generation of Error Message Containing Sensitive Information
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Vertikal Systems | Hospital Manager Backend Services |
Affected:
0 , ≤ September 19, 2025
(custom)
|
Credits
Pundhapat Sichamnong reported these vulnerabilities to CISA.
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-61959",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-30T20:32:04.844198Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-30T20:32:15.522Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Hospital Manager Backend Services",
"vendor": "Vertikal Systems",
"versions": [
{
"lessThanOrEqual": "September 19, 2025",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:vertikal_systems:hospital_manager_backend_services:*:*:*:*:*:*:*:*",
"versionEndIncluding": "september_19,_2025",
"versionStartIncluding": "0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Pundhapat Sichamnong reported these vulnerabilities to CISA."
}
],
"datePublic": "2025-10-28T17:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003ePrior to September 19, 2025, the Hospital Manager Backend Services returned verbose ASP.NET error pages for invalid WebResource.axd requests, disclosing framework and ASP.NET version information, stack traces, internal paths, and the insecure configuration \u0027customErrors mode=\"Off\"\u0027, which could have facilitated reconnaissance by unauthenticated attackers.\u003c/span\u003e\n\n\u003c/span\u003e"
}
],
"value": "Prior to September 19, 2025, the Hospital Manager Backend Services returned verbose ASP.NET error pages for invalid WebResource.axd requests, disclosing framework and ASP.NET version information, stack traces, internal paths, and the insecure configuration \u0027customErrors mode=\"Off\"\u0027, which could have facilitated reconnaissance by unauthenticated attackers."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-209",
"description": "CWE-209 Generation of Error Message Containing Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-29T21:54:51.533Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-25-301-01"
},
{
"url": "https://www.vertikalsystems.com/en/products/pm/contact.php"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eVertikal Systems fixed these vulnerabilities by September 19, 2025. For more information, users should contact \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.vertikalsystems.com/en/products/pm/contact.php\"\u003eVertikal Systems support\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;for assistance.\u003c/span\u003e\n\n\u003cbr\u003e"
}
],
"value": "Vertikal Systems fixed these vulnerabilities by September 19, 2025. For more information, users should contact Vertikal Systems support https://www.vertikalsystems.com/en/products/pm/contact.php \u00a0for assistance."
}
],
"source": {
"advisory": "ICSMA-25-301-01",
"discovery": "EXTERNAL"
},
"title": "Vertikal Systems Hospital Manager Backend Services Generation of Error Message Containing Sensitive Information",
"x_generator": {
"engine": "Vulnogram 0.4.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2025-61959",
"datePublished": "2025-10-29T21:54:51.533Z",
"dateReserved": "2025-10-08T22:13:45.428Z",
"dateUpdated": "2025-10-30T20:32:15.522Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-54459 (GCVE-0-2025-54459)
Vulnerability from nvd – Published: 2025-10-29 21:51 – Updated: 2025-10-30 20:31
VLAI?
Title
Vertikal Systems Hospital Manager Backend Services Exposure of Sensitive System Information to an Unauthorized Control Sphere
Summary
Prior to September 19, 2025, the Hospital Manager Backend Services exposed the ASP.NET tracing endpoint /trace.axd without authentication, allowing a remote attacker to obtain live request traces and sensitive information such as request metadata, session identifiers, authorization headers, server variables, and internal file paths.
Severity ?
CWE
- CWE-497 - Exposure of Sensitive System Information to an Unauthorized Control Sphere
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Vertikal Systems | Hospital Manager Backend Services |
Affected:
0 , ≤ September 19, 2025
(custom)
|
Credits
Pundhapat Sichamnong reported these vulnerabilities to CISA.
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-54459",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-30T20:31:25.447134Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-30T20:31:36.976Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Hospital Manager Backend Services",
"vendor": "Vertikal Systems",
"versions": [
{
"lessThanOrEqual": "September 19, 2025",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:vertikal_systems:hospital_manager_backend_services:*:*:*:*:*:*:*:*",
"versionEndIncluding": "september_19,_2025",
"versionStartIncluding": "0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Pundhapat Sichamnong reported these vulnerabilities to CISA."
}
],
"datePublic": "2025-10-28T17:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003ePrior to September 19, 2025, the Hospital Manager Backend Services exposed the ASP.NET tracing endpoint /trace.axd without authentication, allowing a remote attacker to obtain live request traces and sensitive information such as request metadata, session identifiers, authorization headers, server variables, and internal file paths.\u003c/span\u003e"
}
],
"value": "Prior to September 19, 2025, the Hospital Manager Backend Services exposed the ASP.NET tracing endpoint /trace.axd without authentication, allowing a remote attacker to obtain live request traces and sensitive information such as request metadata, session identifiers, authorization headers, server variables, and internal file paths."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-497",
"description": "CWE-497 Exposure of Sensitive System Information to an Unauthorized Control Sphere",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-29T21:51:34.082Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-25-301-01"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eVertikal Systems fixed these vulnerabilities by September 19, 2025. For more information, users should contact \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.vertikalsystems.com/en/products/pm/contact.php\"\u003eVertikal Systems support\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;for assistance.\u003c/span\u003e\n\n\u003cbr\u003e"
}
],
"value": "Vertikal Systems fixed these vulnerabilities by September 19, 2025. For more information, users should contact Vertikal Systems support https://www.vertikalsystems.com/en/products/pm/contact.php \u00a0for assistance."
}
],
"source": {
"advisory": "ICSMA-25-301-01",
"discovery": "EXTERNAL"
},
"title": "Vertikal Systems Hospital Manager Backend Services Exposure of Sensitive System Information to an Unauthorized Control Sphere",
"x_generator": {
"engine": "Vulnogram 0.4.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2025-54459",
"datePublished": "2025-10-29T21:51:34.082Z",
"dateReserved": "2025-10-08T22:13:45.410Z",
"dateUpdated": "2025-10-30T20:31:36.976Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}