Search criteria

4 vulnerabilities found for iDSecure by Control iD

CVE-2023-6329 (GCVE-0-2023-6329)

Vulnerability from cvelistv5 – Published: 2023-11-27 16:34 – Updated: 2024-08-02 08:28
VLAI?
Summary
An authentication bypass vulnerability exists in Control iD iDSecure v4.7.32.0. The login routine used by iDS-Core.dll contains a "passwordCustom" option that allows an unauthenticated attacker to compute valid credentials that can be used to bypass authentication and act as an administrative user.
CWE
  • CWE-287 - Improper Authentication
Assigner
Impacted products
Vendor Product Version
Control iD iDSecure Affected: 4.7.32.0
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T08:28:21.191Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://tenable.com/security/research/tra-2023-36"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "iDSecure",
          "vendor": "Control iD",
          "versions": [
            {
              "status": "affected",
              "version": "4.7.32.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An authentication bypass vulnerability exists in Control iD iDSecure v4.7.32.0. The login routine used by iDS-Core.dll contains a \"passwordCustom\" option that allows an unauthenticated attacker to compute valid credentials that can be used to bypass authentication and act as an administrative user."
            }
          ],
          "value": "An authentication bypass vulnerability exists in Control iD iDSecure v4.7.32.0. The login routine used by iDS-Core.dll contains a \"passwordCustom\" option that allows an unauthenticated attacker to compute valid credentials that can be used to bypass authentication and act as an administrative user."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-115",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-115 Authentication Bypass"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "CWE-287 Improper Authentication",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-11-28T15:47:13.770Z",
        "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "shortName": "tenable"
      },
      "references": [
        {
          "url": "https://tenable.com/security/research/tra-2023-36"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Control iD iDSecure passwordCustom Authentication Bypass",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
    "assignerShortName": "tenable",
    "cveId": "CVE-2023-6329",
    "datePublished": "2023-11-27T16:34:50.656Z",
    "dateReserved": "2023-11-27T16:18:25.451Z",
    "dateUpdated": "2024-08-02T08:28:21.191Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-2044 (GCVE-0-2023-2044)

Vulnerability from cvelistv5 – Published: 2023-04-14 10:00 – Updated: 2024-08-02 06:12
VLAI?
Summary
A vulnerability has been found in Control iD iDSecure 4.7.29.1 and classified as problematic. This vulnerability affects unknown code of the component Dispositivos Page. The manipulation of the argument IP-DNS leads to cross site scripting. The attack can be initiated remotely. VDB-225922 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CWE
  • CWE-79 - Cross Site Scripting
Assigner
References
https://vuldb.com/?id.225922 vdb-entrytechnical-description
https://vuldb.com/?ctiid.225922 signature
Impacted products
Vendor Product Version
Control iD iDSecure Affected: 4.7.29.1
Create a notification for this product.
Credits
Stux (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T06:12:19.935Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.225922"
          },
          {
            "tags": [
              "signature",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.225922"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "Dispositivos Page"
          ],
          "product": "iDSecure",
          "vendor": "Control iD",
          "versions": [
            {
              "status": "affected",
              "version": "4.7.29.1"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "analyst",
          "value": "Stux (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been found in Control iD iDSecure 4.7.29.1 and classified as problematic. This vulnerability affects unknown code of the component Dispositivos Page. The manipulation of the argument IP-DNS leads to cross site scripting. The attack can be initiated remotely. VDB-225922 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "In Control iD iDSecure 4.7.29.1 wurde eine problematische Schwachstelle gefunden. Betroffen ist eine unbekannte Verarbeitung der Komponente Dispositivos Page. Durch Manipulation des Arguments IP-DNS mit unbekannten Daten kann eine cross site scripting-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 3.5,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:N/I:L/A:N",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 3.5,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:U/C:N/I:L/A:N",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 4,
            "vectorString": "AV:N/AC:L/Au:S/C:N/I:P/A:N",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Cross Site Scripting",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-10-22T09:51:19.858Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.225922"
        },
        {
          "tags": [
            "signature"
          ],
          "url": "https://vuldb.com/?ctiid.225922"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2023-04-14T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2023-04-14T00:00:00.000Z",
          "value": "CVE reserved"
        },
        {
          "lang": "en",
          "time": "2023-04-14T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2023-04-30T16:31:01.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Control iD iDSecure Dispositivos Page cross site scripting"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2023-2044",
    "datePublished": "2023-04-14T10:00:05.920Z",
    "dateReserved": "2023-04-14T06:55:48.287Z",
    "dateUpdated": "2024-08-02T06:12:19.935Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-6329 (GCVE-0-2023-6329)

Vulnerability from nvd – Published: 2023-11-27 16:34 – Updated: 2024-08-02 08:28
VLAI?
Summary
An authentication bypass vulnerability exists in Control iD iDSecure v4.7.32.0. The login routine used by iDS-Core.dll contains a "passwordCustom" option that allows an unauthenticated attacker to compute valid credentials that can be used to bypass authentication and act as an administrative user.
CWE
  • CWE-287 - Improper Authentication
Assigner
Impacted products
Vendor Product Version
Control iD iDSecure Affected: 4.7.32.0
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T08:28:21.191Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://tenable.com/security/research/tra-2023-36"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "iDSecure",
          "vendor": "Control iD",
          "versions": [
            {
              "status": "affected",
              "version": "4.7.32.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An authentication bypass vulnerability exists in Control iD iDSecure v4.7.32.0. The login routine used by iDS-Core.dll contains a \"passwordCustom\" option that allows an unauthenticated attacker to compute valid credentials that can be used to bypass authentication and act as an administrative user."
            }
          ],
          "value": "An authentication bypass vulnerability exists in Control iD iDSecure v4.7.32.0. The login routine used by iDS-Core.dll contains a \"passwordCustom\" option that allows an unauthenticated attacker to compute valid credentials that can be used to bypass authentication and act as an administrative user."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-115",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-115 Authentication Bypass"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "CWE-287 Improper Authentication",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-11-28T15:47:13.770Z",
        "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "shortName": "tenable"
      },
      "references": [
        {
          "url": "https://tenable.com/security/research/tra-2023-36"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Control iD iDSecure passwordCustom Authentication Bypass",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
    "assignerShortName": "tenable",
    "cveId": "CVE-2023-6329",
    "datePublished": "2023-11-27T16:34:50.656Z",
    "dateReserved": "2023-11-27T16:18:25.451Z",
    "dateUpdated": "2024-08-02T08:28:21.191Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-2044 (GCVE-0-2023-2044)

Vulnerability from nvd – Published: 2023-04-14 10:00 – Updated: 2024-08-02 06:12
VLAI?
Summary
A vulnerability has been found in Control iD iDSecure 4.7.29.1 and classified as problematic. This vulnerability affects unknown code of the component Dispositivos Page. The manipulation of the argument IP-DNS leads to cross site scripting. The attack can be initiated remotely. VDB-225922 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CWE
  • CWE-79 - Cross Site Scripting
Assigner
References
https://vuldb.com/?id.225922 vdb-entrytechnical-description
https://vuldb.com/?ctiid.225922 signature
Impacted products
Vendor Product Version
Control iD iDSecure Affected: 4.7.29.1
Create a notification for this product.
Credits
Stux (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T06:12:19.935Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.225922"
          },
          {
            "tags": [
              "signature",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.225922"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "Dispositivos Page"
          ],
          "product": "iDSecure",
          "vendor": "Control iD",
          "versions": [
            {
              "status": "affected",
              "version": "4.7.29.1"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "analyst",
          "value": "Stux (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been found in Control iD iDSecure 4.7.29.1 and classified as problematic. This vulnerability affects unknown code of the component Dispositivos Page. The manipulation of the argument IP-DNS leads to cross site scripting. The attack can be initiated remotely. VDB-225922 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "In Control iD iDSecure 4.7.29.1 wurde eine problematische Schwachstelle gefunden. Betroffen ist eine unbekannte Verarbeitung der Komponente Dispositivos Page. Durch Manipulation des Arguments IP-DNS mit unbekannten Daten kann eine cross site scripting-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 3.5,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:N/I:L/A:N",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 3.5,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:U/C:N/I:L/A:N",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 4,
            "vectorString": "AV:N/AC:L/Au:S/C:N/I:P/A:N",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Cross Site Scripting",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-10-22T09:51:19.858Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.225922"
        },
        {
          "tags": [
            "signature"
          ],
          "url": "https://vuldb.com/?ctiid.225922"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2023-04-14T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2023-04-14T00:00:00.000Z",
          "value": "CVE reserved"
        },
        {
          "lang": "en",
          "time": "2023-04-14T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2023-04-30T16:31:01.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Control iD iDSecure Dispositivos Page cross site scripting"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2023-2044",
    "datePublished": "2023-04-14T10:00:05.920Z",
    "dateReserved": "2023-04-14T06:55:48.287Z",
    "dateUpdated": "2024-08-02T06:12:19.935Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}