All the vulnerabilites related to siemens - ie\/pb-link
Vulnerability from fkie_nvd
Published
2017-05-11 10:29
Modified
2024-11-21 03:23
Summary
Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected.
Impacted products
Vendor Product Version
siemens simatic_cp_343-1_std_firmware *
siemens simatic_cp_343-1_std -
siemens simatic_cp_343-1_lean_firmware *
siemens simatic_cp_343-1_lean -
siemens simatic_cp_343-1_adv_firmware *
siemens simatic_cp_343-1_adv -
siemens simatic_cp_443-1_std_firmware *
siemens simatic_cp_443-1_std -
siemens simatic_cp_443-1_adv_firmware *
siemens simatic_cp_443-1_adv -
siemens simatic_cp_443-1_opc-ua_firmware *
siemens simatic_cp_443-1_opc-ua -
siemens simatic_cp_1243-1_firmware *
siemens simatic_cp_1243-1 -
siemens simatic_cm_1542-1_firmware *
siemens simatic_cm_1542-1 -
siemens simatic_cp_1543sp-1_firmware *
siemens simatic_cp_1542sp-1 -
siemens simatic_cp_1542sp-1_irc_firmware *
siemens simatic_cp_1542sp-1_irc -
siemens simatic_cp_1543sp-1_firmware *
siemens simatic_cp_1543sp-1 -
siemens simatic_cp_1543-1_firmware *
siemens simatic_cp_1543-1 -
siemens simatic_rf650r_firmware *
siemens simatic_rf650r -
siemens simatic_rf680r_firmware *
siemens simatic_rf680r -
siemens simatic_rf685r_firmware *
siemens simatic_rf685r -
siemens simatic_cp_1616_firmware *
siemens simatic_cp_1616 -
siemens simatic_cp_1604_firmware *
siemens simatic_cp_1604 -
siemens simatic_dk-16xx_pn_io_firmware *
siemens simatic_dk-16xx_pn_io -
siemens scalance_x200_firmware *
siemens scalance_x200 -
siemens scalance_x200_irt_firmware *
siemens scalance_x200_irt -
siemens scalance_x300_firmware *
siemens scalance_x300 -
siemens scalance_x408_firmware *
siemens scalance_x408 -
siemens scalance_x414_firmware *
siemens scalance_x414 -
siemens scalance_xm400_firmware *
siemens scalance_xm400 -
siemens scalance_xr500_firmware *
siemens scalance_xr500 -
siemens scalance_w700_firmware *
siemens scalance_w700 -
siemens scalance_m-800_firmware *
siemens scalance_m-800 -
siemens scalance_s615_firmware *
siemens scalance_s615 -
siemens softnet_profinet_io_firmware *
siemens softnet_profinet_io_firmware 14
siemens softnet_profinet_io -
siemens ie\/pb-link_firmware *
siemens ie\/pb-link -
siemens ie\/as-i_link_pn_io_firmware *
siemens ie\/as-i_link_pn_io -
siemens simatic_teleservice_adapter_standard_modem_firmware *
siemens simatic_teleservice_adapter_standard_modem -
siemens simatic_teleservice_adapter_ie_basic_modem_firmware *
siemens simatic_teleservice_adapter_ie_basic_modem -
siemens simatic_teleservice_adapter_ie_advanced_modem_firmware *
siemens simatic_teleservice_adapter_ie_advanced_modem -
siemens sitop_psu8600_firmware *
siemens sitop_psu8600 -
siemens ups1600_profinet_firmware *
siemens ups1600_profinet -
siemens simatic_et_200al_firmware *
siemens simatic_et_200al -
siemens simatic_et_200ecopn_firmware *
siemens simatic_et_200ecopn -
siemens simatic_et_200m_firmware *
siemens simatic_et_200m -
siemens simatic_et_200mp_firmware *
siemens simatic_et_200mp -
siemens simatic_et_200pro_firmware *
siemens simatic_et_200pro -
siemens simatic_et_200s_firmware *
siemens simatic_et_200s -
siemens simatic_et_200sp_firmware *
siemens simatic_et_200sp -
siemens pn\/pn_coupler_firmware *
siemens pn\/pn_coupler -
siemens dk_standard_ethernet_controller_firmware *
siemens dk_standard_ethernet_controller_firmware 4.1.1
siemens dk_standard_ethernet_controller -
siemens ek-ertec_200p_pn_io_firmware *
siemens ek-ertec_200p_pn_io_firmware 4.4.0
siemens ek-ertec_200p_pn_io -
siemens ek-ertec_200_pn_io_firmware *
siemens ek-ertec_200_pn_io_firmware 4.2.1
siemens ek-ertec_200_pn_io -
siemens simatic_s7-200_smart_firmware *
siemens simatic_s7-200_smart -
siemens simatic_s7-300_firmware *
siemens simatic_s7-300 -
siemens simatic_s7-400_firmware *
siemens simatic_s7-400 -
siemens simatic_s7-1200_firmware *
siemens simatic_s7-1200 -
siemens simatic_s7-1500_firmware *
siemens simatic_s7-1500 -
siemens simatic_winac_rtx_firmware *
siemens simatic_winac_rtx_firmware 2010
siemens simatic_winac_rtx -
siemens sirius_act_3su1_firmware *
siemens sirius_act_3su1 -
siemens sirius_soft_starter_3rw44_pn_firmware *
siemens sirius_soft_starter_3rw44_pn -
siemens sirius_motor_starter_m200d_profinet_firmware *
siemens sirius_motor_starter_m200d_profinet -
siemens simocode_pro_v_profinet_firmware *
siemens simocode_pro_v_profinet -
siemens sinamics_dcm_firmware *
siemens sinamics_dcm_firmware 1.4
siemens sinamics_dcm -
siemens sinamics_dcp_firmware *
siemens sinamics_dcp_firmware 1.2
siemens sinamics_dcp -
siemens sinamics_g110m_firmware *
siemens sinamics_g110m_firmware 4.7
siemens sinamics_g110m -
siemens sinamics_g120\(c\/p\/d\)_pn_firmware *
siemens sinamics_g120\(c\/p\/d\)_pn -
siemens sinamics_g130_firmware *
siemens sinamics_g130_firmware 4.7
siemens sinamics_g130 -
siemens sinamics_g150_firmware *
siemens sinamics_g150_firmware 4.7
siemens sinamics_g150 -
siemens sinamics_s110_pn_firmware *
siemens sinamics_s110_pn_firmware 4.4
siemens sinamics_s110_pn -
siemens sinamics_s120_firmware *
siemens sinamics_s120_firmware 4.7
siemens sinamics_s120 -
siemens sinamics_s150_firmware *
siemens sinamics_s150_firmware 4.7
siemens sinamics_s150 -
siemens sinamics_v90_pn_firmware *
siemens sinamics_v90_pn -
siemens simotion_firmware *
siemens simotion_firmware 4.5
siemens simotion -
siemens sinumerik_828d_firmware *
siemens sinumerik_828d_firmware 4.5
siemens sinumerik_828d -
siemens sinumerik_840d_sl_firmware *
siemens sinumerik_840d_sl_firmware 4.5
siemens sinumerik_840d_sl -
siemens simatic_hmi_comfort_panels *
siemens simatic_hmi_comfort_panels -
siemens simatic_hmi_multi_panels *
siemens simatic_hmi_multi_panels -
siemens simatic_hmi_mobile_panels *
siemens simatic_hmi_mobile_panels -
siemens simatic_cp_1243-1_irc_firmware *
siemens simatic_cp_1243-1_irc -
siemens simatic_cp_1243-1_iec_firmware *
siemens simatic_cp_1243-1_iec -
siemens simatic_cp_1243-1_dnp3_firmware *
siemens simatic_cp_1243-1_dnp3 -
siemens simatic_cm_1542sp-1_firmware *
siemens simatic_cm_1542sp-1 -
siemens simatic_s7-1500_software_controller *
siemens sinumerik_828d_firmware *
siemens sinumerik_828d_firmware 4.7
siemens sinumerik_828d -
siemens sinumerik_840d_sl_firmware *
siemens sinumerik_840d_sl_firmware 4.7
siemens sinumerik_840d_sl -
siemens simatic_tdc_cpu555_firmware *
siemens simatic_tdc_cpu555 -
siemens simatic_tdc_cp51m1_firmware *
siemens simatic_tdc_cp51m1 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_343-1_std_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CFF143FA-311E-4081-805F-BBDB72003556",
              "versionEndExcluding": "3.1.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_343-1_std:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9C351559-6D8D-4EA8-87D6-83003844BD97",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_343-1_lean_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "47A5C59B-DAB3-4B05-B9FA-B75685F4AE2A",
              "versionEndExcluding": "3.1.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_343-1_lean:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE2A18E2-F88F-4DC1-81E9-AC836C85A248",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_343-1_adv_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7E0622A2-C918-4062-938A-8736469F8286",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_343-1_adv:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "438184C5-3A2C-4DEE-8FF2-0EFBAA1BA37A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_443-1_std_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BB8BECDB-D55A-4B74-ADEC-CDDBAC4E3481",
              "versionEndExcluding": "3.2.17",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_443-1_std:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BB8C873A-25EB-4787-9F25-DC5852337093",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_443-1_adv_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "58E4035F-02AB-4B6D-A9AF-556DBE021C30",
              "versionEndExcluding": "3.2.17",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_443-1_adv:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "75013961-5B00-42E9-9061-CF2E9A4FC090",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_443-1_opc-ua_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "32DC8BB2-9BC6-4CC2-9CF0-28DF8AEC595A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_443-1_opc-ua:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "977E97C8-959F-4146-8BFD-0FCF014B1534",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EBE1A019-4BC4-4352-BA16-05629A20F89F",
              "versionEndExcluding": "2.1.82",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA9BB25C-D5E3-43DE-8C73-06BDC43CA960",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cm_1542-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6BE0A3E5-0069-4AD5-B287-88BE5D0291F1",
              "versionEndExcluding": "2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cm_1542-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FCB3A00F-252F-4E41-8254-6E8BBD40C4FD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1543sp-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA3E3782-7F36-4BC3-8D00-E1961E3105E3",
              "versionEndExcluding": "1.0.15",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1542sp-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C868560-8BAE-462D-AED0-3C52EA9B6DB8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1542sp-1_irc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A6AF0B55-84D1-46FA-B3A1-81EB2E2FED18",
              "versionEndExcluding": "1.0.15",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1542sp-1_irc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E362CEA5-F47B-4294-8F2D-A0A7AC6FF390",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1543sp-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "496E9B17-BD29-4DE9-96B3-B23E3599C766",
              "versionEndExcluding": "2.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1543sp-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "843A8686-5172-4782-BB97-B5D3C6FB27A3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1543-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "12F7A42E-4D63-4A2A-ABF6-CA08BB6C6234",
              "versionEndExcluding": "1.0.15",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1543-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3FDE92FB-38C7-46E8-9208-BBD7872219D5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf650r_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "37B4E3A9-FE27-4A31-A213-92B461A5C846",
              "versionEndExcluding": "3.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf650r:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C82C2C69-D983-4317-968B-D1855DF8AE43",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf680r_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "177A6E55-8D64-4CB8-B366-AE272E715932",
              "versionEndExcluding": "3.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf680r:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "450DE127-DFED-4799-B8EA-0F95028E4BC3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf685r_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "72D14DB5-6132-4442-8AB2-3ECE89B1D47C",
              "versionEndExcluding": "3.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf685r:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "63F70060-0090-4BD7-8BF6-769989879ACD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1616_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4FDC53A8-3F99-481E-9B0A-F5AF296B5BD6",
              "versionEndExcluding": "2.7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1616:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA074FBE-1C3E-4441-8C51-52B555B85D9F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1604_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0424AECD-68D5-45F1-9F55-B72CB4DFE39C",
              "versionEndExcluding": "2.7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1604:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6304FA24-F194-4EE2-95F5-35D086F82C01",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_dk-16xx_pn_io_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "26113F2F-8C5E-471B-9E12-AA3B3860B5CF",
              "versionEndExcluding": "2.7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_dk-16xx_pn_io:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA0D867D-737F-4CEC-BAEA-9ADE0BA2303E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x200_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "45008AE8-8386-4CBA-8C38-10C1A60150C2",
              "versionEndExcluding": "5.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A59C91EA-5D1B-4970-8C36-BD76BA420B12",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x200_irt_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F61995A-2018-4DAA-9529-BADC145B267F",
              "versionEndExcluding": "5.4.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x200_irt:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CAF3DA7A-6B80-4F20-835F-BF071197D1B0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x300_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC97A506-7E63-43A3-ACB0-DDAF3C5369C3",
              "versionEndExcluding": "4.1.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x300:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E3F6299B-D7E3-4750-B016-7DCBC83C2287",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x408_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B8A4CF89-9DDA-4974-A886-CC0A912017F7",
              "versionEndExcluding": "4.1.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x408:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "47F713E4-4B75-476E-BC21-92CA10198AE9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x414_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2CA7C987-779A-4B64-BFAC-73D54618AF04",
              "versionEndExcluding": "3.10.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x414:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7E4C1BEF-D6B4-4260-9AC5-6F903EF6F4B1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xm400_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F6EB11E9-4036-4A93-91DC-4D987B5FE2BA",
              "versionEndExcluding": "6.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xm400:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9FC408A8-903F-43A2-9D05-65AD4482FDBB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr500_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B9AF696-211F-4CAD-8A0E-402487E8DC50",
              "versionEndExcluding": "6.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr500:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "080E722F-FCD4-4967-86EE-151ADC5702E7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w700_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D8763BB9-5DDA-4817-BDA6-63983CD4BC67",
              "versionEndExcluding": "6.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w700:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D3033B1E-57A6-4AE3-A861-7047CF8EAD79",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_m-800_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B74BBB98-0146-467E-B77B-E2FA1ABF2ED5",
              "versionEndExcluding": "4.03",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_m-800:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFB9921A-5204-40A3-88AB-B7755F5C6875",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_s615_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B2345F75-2CD1-4014-8F90-36A4FB4CC3BE",
              "versionEndExcluding": "4.03",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E917CBBB-EF41-4113-B0CA-EB91889235E7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:softnet_profinet_io_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9831567D-6528-4ACA-99F9-1EC42CB4A90D",
              "versionEndExcluding": "14",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:softnet_profinet_io_firmware:14:-:*:*:*:*:*:*",
              "matchCriteriaId": "27BC04E4-8C6F-4A66-86C4-A8F793A10BDD",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:softnet_profinet_io:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E348069A-B809-4DF6-81E9-DC52C6E2C268",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:ie\\/pb-link_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8ED91175-0AF3-424A-8C49-43587BB95EAB",
              "versionEndExcluding": "3.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:ie\\/pb-link:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8D43C16C-0719-4648-903F-6CC0FFF1835A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:ie\\/as-i_link_pn_io_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7E909C1E-9329-4459-ACE3-AD906CD4A968",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:ie\\/as-i_link_pn_io:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "317863B6-0B71-4D03-83FE-FC59EBB5307C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_teleservice_adapter_standard_modem_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A9F37323-B072-470B-B770-9735B84CACFE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_teleservice_adapter_standard_modem:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "610DF0CA-D0FA-4CBE-8383-6F038E7AC4C3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_teleservice_adapter_ie_basic_modem_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B366E4A-4223-4A42-9A05-52EB23BCF209",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_teleservice_adapter_ie_basic_modem:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "98FB86B6-DB8A-42EF-BA60-68D96B6FE8B6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_teleservice_adapter_ie_advanced_modem_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7CD7CAEE-9C1A-4520-8F85-FD9BFB0A57D9",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_teleservice_adapter_ie_advanced_modem:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BF513598-C3FA-4555-8133-A7276DDAFAC8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sitop_psu8600_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5468C9FA-ADD9-4FD3-89FE-C3621F5CB0EC",
              "versionEndExcluding": "1.2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sitop_psu8600:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "55058209-8AE5-42AF-80D4-5A7A44307266",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:ups1600_profinet_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "54B85DBA-24CA-4F95-89A5-D53D5AC69B0E",
              "versionEndExcluding": "2.2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:ups1600_profinet:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "ECC84D6F-F5E0-47CF-B11E-1C43F866D972",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200al_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C9D0595-53CD-48C0-82E3-DB0B2EC17721",
              "versionEndExcluding": "1.0.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200al:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "34C17B00-34B5-4A15-9333-252BE2975F37",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200ecopn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3EE0B998-E408-408F-8F78-5E90F74E9C9B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200ecopn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0259EAE9-0CA0-49A5-A573-8339604A181B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200m_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "14E56570-5C20-40BD-BF0B-F6ED06AFC8F7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200m:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7037E46B-4FE5-4693-B6A6-B5AF7B652C4F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200mp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "55BE63B0-F44E-4FCD-B00C-77595BACC62E",
              "versionEndExcluding": "4.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200mp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "49DA8715-D671-4D8F-A870-E61960A5AFA4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200pro_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D054139B-BE36-4B34-88AE-BC487DCB1DCB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200pro:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F0CE2EC-9A73-4576-A389-A19893D47B0F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200s_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BB063929-AAB0-4FF8-BCA3-71BA80517B1A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200s:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A1EC40E7-F004-446C-B5C9-0AB9911105E0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200sp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3237684A-3BEA-462F-A91D-ABC94C90D15A",
              "versionEndExcluding": "4.2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200sp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "691CA334-4394-4ED6-B417-F67FC92228AE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:pn\\/pn_coupler_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "32BD232D-A6BB-4D7B-BD00-1085D08D8A77",
              "versionEndExcluding": "4.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:pn\\/pn_coupler:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB2846BD-9DAB-44A2-87C9-39E3ACFE03FA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0FE40195-DE5A-4B9C-9455-FAF92FF090D0",
              "versionEndExcluding": "4.1.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:4.1.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "9B339839-3D74-4E13-9EB6-24CA46F991A5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:dk_standard_ethernet_controller:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "53DF35F1-94FF-4D0B-9FA2-E8B0AFAEA5FF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:ek-ertec_200p_pn_io_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E9329BF4-D00A-4138-AA4C-93022002C0B9",
              "versionEndExcluding": "4.4.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:ek-ertec_200p_pn_io_firmware:4.4.0:-:*:*:*:*:*:*",
              "matchCriteriaId": "7863DDDC-D5CE-44FE-89C4-0E8A702A91A8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:ek-ertec_200p_pn_io:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E62802E3-AFA3-4023-9671-95C220397956",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:ek-ertec_200_pn_io_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8C46E084-9732-4920-86C2-3A91830CBCE3",
              "versionEndExcluding": "4.2.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:ek-ertec_200_pn_io_firmware:4.2.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "18C8B2FB-87C3-4DBB-9960-53FA545F26CB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:ek-ertec_200_pn_io:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "42D3FAF4-9B78-4EEF-8D80-17E9B98228D2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-200_smart_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "251EE4B2-F1C7-4ACF-B90D-4C0FE3D181E5",
              "versionEndExcluding": "2.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-200_smart:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "598EEFC9-5240-4011-9017-A9557585AA19",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-300_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9461CADE-1624-4D1B-8CF2-CF65F75071C0",
              "versionEndExcluding": "3.3.17",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-300:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7EFD4E99-5C66-443F-8B6F-FA01C895DE78",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-400_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2570E321-C28E-46FA-8693-1230B3B5FD1B",
              "versionEndExcluding": "6.0.6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-400:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8F97B67B-4516-4AD9-B33C-7F480EE0DB4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "582B49BD-4565-4D19-BBE6-A193BDFCE8B0",
              "versionEndExcluding": "4.2.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EC545350-FD53-4B2E-886F-E20F12260C9B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D24953B-B3DF-4150-810C-64A94A55E829",
              "versionEndExcluding": "2.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "30DDEA9B-E1BF-4572-8E12-D13C54603E77",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_winac_rtx_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "80BDBB38-20D2-48C3-8B58-62C2D8CC00B8",
              "versionEndExcluding": "2010",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_winac_rtx_firmware:2010:-:*:*:*:*:*:*",
              "matchCriteriaId": "EA59D713-F342-4CDA-BDC8-108352D385DA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_winac_rtx:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA5ADAB0-3985-4933-8CDD-D1546D8271CC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sirius_act_3su1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4E36412A-1AAB-42D1-B0B4-7A7BBF3CB317",
              "versionEndExcluding": "1.1.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sirius_act_3su1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8582A3E8-C05E-4D0B-851D-8C3181ED61CC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sirius_soft_starter_3rw44_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F84A65E6-4672-4B62-826E-6FAAE0B4A89D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sirius_soft_starter_3rw44_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CBB058FA-3E70-4489-AAB1-0CB7EF16A2E7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sirius_motor_starter_m200d_profinet_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3D42184E-8998-4C40-9612-5C9DE193CC06",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sirius_motor_starter_m200d_profinet:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BA5CB62E-04B7-4DD3-AA06-EB4A4FA58E54",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simocode_pro_v_profinet_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "98FDB53A-8F5D-46AA-9366-F6480B12D744",
              "versionEndExcluding": "2.0.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simocode_pro_v_profinet:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "352651A0-F7CE-4689-8597-15F3764707A9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_dcm_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FD2943F3-C46C-462E-9062-EE7B3E56CF72",
              "versionEndExcluding": "1.4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_dcm_firmware:1.4:-:*:*:*:*:*:*",
              "matchCriteriaId": "975EFBBB-33E1-4D04-9E06-93553D45539C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_dcm:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A1A43D34-ECA3-4330-B85F-02BDD1D22149",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_dcp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5D7A7140-62A2-434F-AB79-1D47C918F1FE",
              "versionEndExcluding": "1.2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_dcp_firmware:1.2:-:*:*:*:*:*:*",
              "matchCriteriaId": "A2B61A79-C2B0-4C3D-A63C-B20FF78B2981",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_dcp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B75F50CA-7371-4BC7-8D8A-13F8BC69E4EB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_g110m_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "775C90BB-C026-435C-889A-517EF85656C5",
              "versionEndExcluding": "4.7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_g110m_firmware:4.7:-:*:*:*:*:*:*",
              "matchCriteriaId": "CAA92AC6-7DA0-418D-A13F-69268DFD7966",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_g110m:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D61D3E9C-1346-4354-BCD9-B02F67500C41",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_g120\\(c\\/p\\/d\\)_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "21ED7835-5D9B-4AF0-8E71-A4E7377FAD9F",
              "versionEndExcluding": "4.7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_g120\\(c\\/p\\/d\\)_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "64E77B7F-3E48-4C2C-9E2E-4AAEA6BCA71A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_g130_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B3B0706-47CD-43FB-8E3A-7EEEF020AFBA",
              "versionEndExcluding": "4.7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_g130_firmware:4.7:-:*:*:*:*:*:*",
              "matchCriteriaId": "1D36CF8D-6DA4-49ED-9EF1-F96292F671EE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_g130:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "373DBE44-AC28-4D04-93BB-35CD8C60E899",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_g150_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AC731378-CB83-4C15-BC6A-5A86DF9B62F1",
              "versionEndExcluding": "4.7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_g150_firmware:4.7:-:*:*:*:*:*:*",
              "matchCriteriaId": "51A78A0B-5D75-418A-98AC-6EBF50D89A8A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_g150:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2296CA65-0E89-4BCB-8003-E7212BF1F585",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_s110_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "35B36BC1-EE75-48D5-B511-C79891DA0F86",
              "versionEndExcluding": "4.4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_s110_pn_firmware:4.4:-:*:*:*:*:*:*",
              "matchCriteriaId": "8C21EF20-693C-425F-A370-E84722856212",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_s110_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A4D7197E-C921-42CA-BE43-C96A4223F443",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "77A0BE57-1A9A-4564-9C53-CF47DEEF7991",
              "versionEndExcluding": "4.7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:4.7:-:*:*:*:*:*:*",
              "matchCriteriaId": "376556D0-1AE2-4F80-B3CE-C0251E35C326",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E5A824BD-935F-4E53-8313-C5544B0489C7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_s150_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "772FF972-2193-4639-B454-F92762E49C39",
              "versionEndExcluding": "4.7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_s150_firmware:4.7:-:*:*:*:*:*:*",
              "matchCriteriaId": "EE2B31F0-D45F-4B42-95D2-540C68C5F3DE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_s150:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0D48682C-A39D-4A09-B904-50FA64A9D2A5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_v90_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8EE54303-4FDA-42C7-B33B-BA884CD31339",
              "versionEndExcluding": "1.01",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_v90_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D870F289-F2BC-4105-A8F0-30E47CDE9FEF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simotion_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "92A7198A-D6C5-4FBF-8860-5C8EA864718B",
              "versionEndExcluding": "4.5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simotion_firmware:4.5:-:*:*:*:*:*:*",
              "matchCriteriaId": "B5DA6BF7-ECB8-47F1-A791-E65CFF89A608",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simotion:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "879CF09E-4735-4A73-8E7B-215F2701F7E0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinumerik_828d_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "71CD07D8-ECED-47EF-B2BC-0585F9BB00C1",
              "versionEndExcluding": "4.5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinumerik_828d_firmware:4.5:-:*:*:*:*:*:*",
              "matchCriteriaId": "AEB948AA-7BD7-4A0F-B86E-38ECD722C086",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinumerik_828d:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7D97047C-9772-4AEB-B993-131EBBAE33BA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinumerik_840d_sl_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "28E3AB24-86B4-485D-8D3A-131E5C7F0108",
              "versionEndExcluding": "4.5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinumerik_840d_sl_firmware:4.5:-:*:*:*:*:*:*",
              "matchCriteriaId": "40AC387B-B799-4A34-8C9E-73D05B86801D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinumerik_840d_sl:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "765286DF-07EC-4C7A-AB8C-09559CD977EA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CE53BC8E-CDA7-476A-87CA-532F365C79A7",
              "versionEndExcluding": "15.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3BCFE761-35C9-43EF-85BC-E8083B9F75CB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_multi_panels:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A1150AED-CDBE-492C-95FF-3E02B3B447F1",
              "versionEndExcluding": "15.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_multi_panels:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1AAE6A83-737B-47A9-86BB-652C7F6A8013",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_mobile_panels:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "42E8D21B-9CF4-4C2E-B33C-212BA29C7124",
              "versionEndExcluding": "15.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_mobile_panels:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "55E03180-BE77-4A22-A6C1-FE90B9760570",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-1_irc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "02610368-4B97-4B3F-8592-64CF8F65D8AD",
              "versionEndExcluding": "2.1.82",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-1_irc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "61E7964A-E7A4-4CDE-B376-5BBEC5F00A73",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-1_iec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BE5003DA-5488-47C1-B442-9137E849FDD5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-1_iec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFE96226-A2DF-4A9E-8CBB-8D7CF328E404",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-1_dnp3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FCF9D803-FF47-4400-B2C4-1F4EE28E5AA8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-1_dnp3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FFBFB96-1A35-4724-831B-68E3A9C32921",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cm_1542sp-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8BF91884-7532-4E15-A754-EBC430FD0E9D",
              "versionEndExcluding": "1.0.15",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cm_1542sp-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "921D7568-9FE9-4491-B099-A922984351DC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_s7-1500_software_controller:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "64D5B21D-0DC1-479B-810B-21E78F34A80A",
              "versionEndExcluding": "2.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinumerik_828d_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "45B42950-8BD9-4933-9615-27FCC67C03A1",
              "versionEndExcluding": "4.7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinumerik_828d_firmware:4.7:-:*:*:*:*:*:*",
              "matchCriteriaId": "86ADBE36-CC1F-4F3C-81CA-ABA0F40AC212",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinumerik_828d:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7D97047C-9772-4AEB-B993-131EBBAE33BA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinumerik_840d_sl_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6377EA6B-8EE3-4208-8FB0-175684A77B3F",
              "versionEndExcluding": "4.7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinumerik_840d_sl_firmware:4.7:-:*:*:*:*:*:*",
              "matchCriteriaId": "D5AE6E9A-02B9-4A69-ACC4-EFBE1767E51E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinumerik_840d_sl:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "765286DF-07EC-4C7A-AB8C-09559CD977EA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_tdc_cpu555_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D87643C3-6525-4CBD-BC0C-6B4DC30C8642",
              "versionEndExcluding": "1.1.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_tdc_cpu555:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AE6AB995-D67B-43E5-B8FF-97C38D20CB10",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_tdc_cp51m1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5C936A7A-1AF9-44E4-9CEC-0694A424616B",
              "versionEndExcluding": "1.1.8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_tdc_cp51m1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8DA1E7C4-6352-41A4-8A94-C24DDB456572",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected."
    },
    {
      "lang": "es",
      "value": "Los paquetes PROFINET DCP especialmente dise\u00f1ados que se env\u00edan en un segmento Ethernet local (capa 2) a un producto afectado podr\u00edan causar una condici\u00f3n de denegaci\u00f3n de servicio de ese producto. Se requiere la interacci\u00f3n humana para recuperar el sistema. Las interfaces PROFIBUS no est\u00e1n afectadas. Esta vulnerabilidad s\u00f3lo afecta a los SIMATIC HMI Multi Panels y HMI Mobile Panels, y a los dispositivos S7-300/S7-400"
    }
  ],
  "id": "CVE-2017-2681",
  "lastModified": "2024-11-21T03:23:57.917",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "ADJACENT_NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 6.1,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 6.5,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "productcert@siemens.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "ADJACENT",
          "automatable": "NOT_DEFINED",
          "availabilityRequirements": "NOT_DEFINED",
          "baseScore": 7.1,
          "baseSeverity": "HIGH",
          "confidentialityRequirements": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirements": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubsequentSystemAvailability": "NOT_DEFINED",
          "modifiedSubsequentSystemConfidentiality": "NOT_DEFINED",
          "modifiedSubsequentSystemIntegrity": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnerableSystemAvailability": "NOT_DEFINED",
          "modifiedVulnerableSystemConfidentiality": "NOT_DEFINED",
          "modifiedVulnerableSystemIntegrity": "NOT_DEFINED",
          "privilegesRequired": "NONE",
          "providerUrgency": "NOT_DEFINED",
          "recovery": "NOT_DEFINED",
          "safety": "NOT_DEFINED",
          "subsequentSystemAvailability": "NONE",
          "subsequentSystemConfidentiality": "NONE",
          "subsequentSystemIntegrity": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnerabilityResponseEffort": "NOT_DEFINED",
          "vulnerableSystemAvailability": "HIGH",
          "vulnerableSystemConfidentiality": "NONE",
          "vulnerableSystemIntegrity": "NONE"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2017-05-11T10:29:00.180",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/98369"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securitytracker.com/id/1038463"
    },
    {
      "source": "productcert@siemens.com",
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Broken Link"
      ],
      "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/98369"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securitytracker.com/id/1038463"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Broken Link"
      ],
      "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-400"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-400"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2017-05-11 01:29
Modified
2024-11-21 03:23
Summary
Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected.
References
productcert@siemens.comhttp://www.securityfocus.com/bid/98369Third Party Advisory, VDB Entry
productcert@siemens.comhttp://www.securitytracker.com/id/1038463Third Party Advisory, VDB Entry
productcert@siemens.comhttps://cert-portal.siemens.com/productcert/html/ssa-284673.html
productcert@siemens.comhttps://cert-portal.siemens.com/productcert/html/ssa-293562.html
productcert@siemens.comhttps://cert-portal.siemens.com/productcert/html/ssa-546832.html
productcert@siemens.comhttps://cert-portal.siemens.com/productcert/pdf/ssa-284673.pdfVendor Advisory
productcert@siemens.comhttps://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdfVendor Advisory
productcert@siemens.comhttps://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdfVendor Advisory
productcert@siemens.comhttps://ics-cert.us-cert.gov/advisories/ICSA-18-023-02Third Party Advisory, US Government Resource
productcert@siemens.comhttps://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdfBroken Link
af854a3a-2127-422b-91ae-364da2661108http://www.securityfocus.com/bid/98369Third Party Advisory, VDB Entry
af854a3a-2127-422b-91ae-364da2661108http://www.securitytracker.com/id/1038463Third Party Advisory, VDB Entry
af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/html/ssa-284673.html
af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/html/ssa-293562.html
af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/html/ssa-546832.html
af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/pdf/ssa-284673.pdfVendor Advisory
af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdfVendor Advisory
af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdfVendor Advisory
af854a3a-2127-422b-91ae-364da2661108https://ics-cert.us-cert.gov/advisories/ICSA-18-023-02Third Party Advisory, US Government Resource
af854a3a-2127-422b-91ae-364da2661108https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdfBroken Link
Impacted products
Vendor Product Version
siemens simatic_cp_343-1_std_firmware *
siemens simatic_cp_343-1_std -
siemens simatic_cp_343-1_lean_firmware *
siemens simatic_cp_343-1_lean -
siemens simatic_cp_343-1_adv_firmware *
siemens simatic_cp_343-1_adv -
siemens simatic_cp_443-1_std_firmware *
siemens simatic_cp_443-1_std -
siemens simatic_cp_443-1_adv_firmware *
siemens simatic_cp_443-1_adv -
siemens simatic_cp_443-1_opc-ua_firmware *
siemens simatic_cp_443-1_opc-ua -
siemens simatic_cp_1243-1_firmware *
siemens simatic_cp_1243-1 -
siemens simatic_cm_1542-1_firmware *
siemens simatic_cm_1542-1 -
siemens simatic_cp_1542sp-1_firmware *
siemens simatic_cp_1542sp-1 -
siemens simatic_cp_1542sp-1_irc_firmware *
siemens simatic_cp_1542sp-1_irc -
siemens simatic_cp_1543sp-1_firmware *
siemens simatic_cp_1543sp-1 -
siemens simatic_cp_1543-1_firmware *
siemens simatic_cp_1543-1 -
siemens simatic_rf650r_firmware *
siemens simatic_rf650r -
siemens simatic_rf680r_firmware *
siemens simatic_rf680r -
siemens simatic_rf685r_firmware *
siemens simatic_rf685r -
siemens simatic_cp_1616_firmware *
siemens simatic_cp_1616 -
siemens simatic_cp_1604_firmware *
siemens simatic_cp_1604 -
siemens simatic_dk-1616_pn_io_firmware *
siemens simatic_dk-1616_pn_io -
siemens scalance_x200_firmware *
siemens scalance_x200 -
siemens scalance_x200_irt_firmware *
siemens scalance_x200_irt -
siemens scalance_x300_firmware *
siemens scalance_x300 -
siemens scalance_x408_firmware *
siemens scalance_x408 -
siemens scalance_x414_firmware *
siemens scalance_x414 -
siemens scalance_xm400_firmware *
siemens scalance_xm400 -
siemens scalance_xr500_firmware *
siemens scalance_xr500 -
siemens scalance_w700_firmware *
siemens scalance_w700 -
siemens scalance_m-800_firmware *
siemens scalance_m-800 -
siemens scalance_s615_firmware *
siemens scalance_s615 -
siemens softnet_profinet_io_firmware *
siemens softnet_profinet_io_firmware 14
siemens softnet_profinet_io -
siemens ie\/pb-link_firmware *
siemens ie\/pb-link -
siemens ie\/as-i_link_pn_io_firmware *
siemens ie\/as-i_link_pn_io -
siemens simatic_teleservice_adapter_ie_standard_firmware *
siemens simatic_teleservice_adapter_ie_standard -
siemens simatic_teleservice_adapter_ie_basic_firmware *
siemens simatic_teleservice_adapter_ie_basic -
siemens simatic_teleservice_adapter_ie_advanced_firmware *
siemens simatic_teleservice_adapter_ie_advanced_modem -
siemens sitop_psu8600_firmware *
siemens sitop_psu8600 -
siemens ups1600_profinet_firmware *
siemens ups1600_profinet -
siemens simatic_et_200al_firmware *
siemens simatic_et_200al -
siemens simatic_et_200ecopn_firmware *
siemens simatic_et_200ecopn -
siemens simatic_et_200m_firmware *
siemens simatic_et_200m -
siemens simatic_et_200mp_firmware *
siemens simatic_et_200mp -
siemens simatic_et_200pro_firmware *
siemens simatic_et_200pro -
siemens simatic_et_200s_firmware *
siemens simatic_et_200s -
siemens simatic_et_200sp_firmware *
siemens simatic_et_200sp -
siemens pn\/pn_coupler_firmware *
siemens pn\/pn_coupler -
siemens dk_standard_ethernet_controller_firmware *
siemens dk_standard_ethernet_controller_firmware 4.1.1
siemens dk_standard_ethernet_controller -
siemens ek-ertec_200p_pn_io_firmware *
siemens ek-ertec_200p_pn_io_firmware 4.4.0
siemens ek-ertec_200p_pn_io -
siemens ek-ertec_200_pn_io_firmware *
siemens ek-ertec_200_pn_io_firmware 4.2.1
siemens ek-ertec_200_pn_io -
siemens simatic_s7-200_smart_firmware *
siemens simatic_s7-200_smart -
siemens simatic_s7-300_firmware -
siemens simatic_s7-300 -
siemens simatic_s7-400_firmware *
siemens simatic_s7-400 -
siemens simatic_s7-1200_firmware *
siemens simatic_s7-1200 -
siemens simatic_s7-1500_firmware *
siemens simatic_s7-1500 -
siemens simatic_s7-1500_software_controller_firmware *
siemens simatic_s7-1500_software_controller -
siemens simatic_winac_rtx_firmware *
siemens simatic_winac_rtx_firmware 2010
siemens simatic_winac_rtx -
siemens sirius_act_3su1_firmware *
siemens sirius_act_3su1 -
siemens sirius_soft_starter_3rw44_pn_firmware *
siemens sirius_soft_starter_3rw44_pn -
siemens sirius_motor_starter_m200d_profinet_firmware *
siemens sirius_motor_starter_m200d_profinet -
siemens simocode_pro_v_profinet_firmware *
siemens simocode_pro_v_profinet -
siemens sinamics_dcm_firmware *
siemens sinamics_dcm_firmware 1.4
siemens sinamics_dcm_firmware 1.4
siemens sinamics_dcm -
siemens sinamics_dcp_firmware *
siemens sinamics_dcp_firmware 1.2
siemens sinamics_dcp -
siemens sinamics_g110m_firmware *
siemens sinamics_g110m_firmware 4.7
siemens sinamics_g110m -
siemens sinamics_g120\(c\/p\/d\)_w._pn_firmware *
siemens sinamics_g120\(c\/p\/d\)_w._pn_firmware 4.7
siemens sinamics_g120\(c\/p\/d\)_w._pn -
siemens sinamics_g130_firmware *
siemens sinamics_g130_firmware 4.7
siemens sinamics_g130 -
siemens sinamics_g150_firmware *
siemens sinamics_g150_firmware 4.7
siemens sinamics_g150 -
siemens sinamics__s110_pn_firmware *
siemens sinamics__s110_pn_firmware 4.4
siemens _s110_pn -
siemens sinamics_s120_firmware *
siemens sinamics_s120_firmware 4.7
siemens sinamics_s120 -
siemens sinamics_s150_firmware *
siemens sinamics_s150_firmware 4.7
siemens sinamics_s150 -
siemens sinamics_v90_pn_firmware *
siemens sinamics_v90_pn -
siemens simotion_firmware *
siemens simotion_firmware 4.5
siemens simotion -
siemens sinumerik_828d_firmware *
siemens sinumerik_828d_firmware 4.5
siemens sinumerik_828d -
siemens sinumerik_840d_sl_firmware *
siemens sinumerik_840d_sl_firmware 4.5
siemens sinumerik_840d_sl -
siemens simatic_hmi_comfort_panels *
siemens simatic_hmi_comfort_panels -
siemens simatic_hmi_multi_panels *
siemens simatic_hmi_multi_panels -
siemens simatic_hmi_mobile_panels *
siemens simatic_hmi_mobile_panels -
siemens simatic_cp_1243-1_irc_firmware *
siemens simatic_cp_1243-1_irc -
siemens simatic_cp_1243-1_iec_firmware *
siemens simatic_cp_1243-1_iec -
siemens simatic_cp_1243-1_dnp3_firmware *
siemens simatic_cp_1243-1_dnp3 -
siemens simatic_dk-1604_pn_io_firmware *
siemens simatic_dk-1604_pn_io -
siemens simatic_tdc_cpu555_firmware *
siemens simatic_tdc_cpu555 -
siemens simatic_tdc_cp51m1_firmware *
siemens simatic_tdc_cp51m1 -
siemens sinamics_gh150_firmware *
siemens sinamics_gh150_firmware 4.7
siemens sinamics_gh150 -
siemens sinamics_gl150_firmware *
siemens sinamics_gl150_firmware 4.8
siemens sinamics_gl150 -
siemens sinamics_gm150_firmware *
siemens sinamics_gm150_firmware 4.7
siemens sinamics_gm150 -
siemens sinamics_sl150_firmware *
siemens sinamics_sl150_firmware 4.8
siemens sinamics_sl150 -
siemens sinamics_sm120_firmware *
siemens sinamics_sm120_firmware 4.8
siemens sinamics_sm120 -
siemens extension_unit_12_profinet_firmware *
siemens extension_unit_12_profinet -
siemens extension_unit_15_profinet_firmware *
siemens extension_unit_15_profinet -
siemens extension_unit_19_profinet_firmware *
siemens extension_unit_19_profinet -
siemens extension_unit_22_profinet_firmware *
siemens extension_unit_22_profinet -
siemens simatic_cp_1242-7_gprs_firmware *
siemens simatic_cp_1242-7_gprs -
siemens simatic_cp_1243-7_lte\/us_firmware *
siemens simatic_cp_1243-7_lte\/us -
siemens simatic_cp_1243-8_firmware *
siemens simatic_cp_1243-8 -
siemens simatic_cp_1626_firmware *
siemens simatic_cp_1626 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_343-1_std_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CFF143FA-311E-4081-805F-BBDB72003556",
              "versionEndExcluding": "3.1.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_343-1_std:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9C351559-6D8D-4EA8-87D6-83003844BD97",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_343-1_lean_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "47A5C59B-DAB3-4B05-B9FA-B75685F4AE2A",
              "versionEndExcluding": "3.1.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_343-1_lean:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE2A18E2-F88F-4DC1-81E9-AC836C85A248",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_343-1_adv_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7E0622A2-C918-4062-938A-8736469F8286",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_343-1_adv:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "438184C5-3A2C-4DEE-8FF2-0EFBAA1BA37A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_443-1_std_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BB8BECDB-D55A-4B74-ADEC-CDDBAC4E3481",
              "versionEndExcluding": "3.2.17",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_443-1_std:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BB8C873A-25EB-4787-9F25-DC5852337093",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_443-1_adv_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "58E4035F-02AB-4B6D-A9AF-556DBE021C30",
              "versionEndExcluding": "3.2.17",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_443-1_adv:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "75013961-5B00-42E9-9061-CF2E9A4FC090",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_443-1_opc-ua_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "32DC8BB2-9BC6-4CC2-9CF0-28DF8AEC595A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_443-1_opc-ua:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "977E97C8-959F-4146-8BFD-0FCF014B1534",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EBE1A019-4BC4-4352-BA16-05629A20F89F",
              "versionEndExcluding": "2.1.82",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA9BB25C-D5E3-43DE-8C73-06BDC43CA960",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cm_1542-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6BE0A3E5-0069-4AD5-B287-88BE5D0291F1",
              "versionEndExcluding": "2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cm_1542-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FCB3A00F-252F-4E41-8254-6E8BBD40C4FD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1542sp-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "18B597C8-0401-458F-8DF9-062B5E833115",
              "versionEndExcluding": "1.0.15",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1542sp-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C868560-8BAE-462D-AED0-3C52EA9B6DB8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1542sp-1_irc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A6AF0B55-84D1-46FA-B3A1-81EB2E2FED18",
              "versionEndExcluding": "1.0.15",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1542sp-1_irc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E362CEA5-F47B-4294-8F2D-A0A7AC6FF390",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1543sp-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA3E3782-7F36-4BC3-8D00-E1961E3105E3",
              "versionEndExcluding": "1.0.15",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1543sp-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "843A8686-5172-4782-BB97-B5D3C6FB27A3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1543-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "807D97E1-7680-4B8F-85AD-F56F039669D1",
              "versionEndExcluding": "2.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1543-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3FDE92FB-38C7-46E8-9208-BBD7872219D5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf650r_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "37B4E3A9-FE27-4A31-A213-92B461A5C846",
              "versionEndExcluding": "3.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf650r:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C82C2C69-D983-4317-968B-D1855DF8AE43",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf680r_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "177A6E55-8D64-4CB8-B366-AE272E715932",
              "versionEndExcluding": "3.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf680r:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "450DE127-DFED-4799-B8EA-0F95028E4BC3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf685r_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "72D14DB5-6132-4442-8AB2-3ECE89B1D47C",
              "versionEndExcluding": "3.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf685r:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "63F70060-0090-4BD7-8BF6-769989879ACD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1616_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4FDC53A8-3F99-481E-9B0A-F5AF296B5BD6",
              "versionEndExcluding": "2.7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1616:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA074FBE-1C3E-4441-8C51-52B555B85D9F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1604_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0424AECD-68D5-45F1-9F55-B72CB4DFE39C",
              "versionEndExcluding": "2.7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1604:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6304FA24-F194-4EE2-95F5-35D086F82C01",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_dk-1616_pn_io_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "39663B8F-F349-49B3-A0CB-004F11D01E34",
              "versionEndExcluding": "2.7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_dk-1616_pn_io:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C8F515DF-36AC-49C1-B013-E87529775AB3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x200_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "45008AE8-8386-4CBA-8C38-10C1A60150C2",
              "versionEndExcluding": "5.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A59C91EA-5D1B-4970-8C36-BD76BA420B12",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x200_irt_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F61995A-2018-4DAA-9529-BADC145B267F",
              "versionEndExcluding": "5.4.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x200_irt:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CAF3DA7A-6B80-4F20-835F-BF071197D1B0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x300_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC97A506-7E63-43A3-ACB0-DDAF3C5369C3",
              "versionEndExcluding": "4.1.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x300:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E3F6299B-D7E3-4750-B016-7DCBC83C2287",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x408_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B8A4CF89-9DDA-4974-A886-CC0A912017F7",
              "versionEndExcluding": "4.1.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x408:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "47F713E4-4B75-476E-BC21-92CA10198AE9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_x414_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2CA7C987-779A-4B64-BFAC-73D54618AF04",
              "versionEndExcluding": "3.10.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x414:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7E4C1BEF-D6B4-4260-9AC5-6F903EF6F4B1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xm400_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F6EB11E9-4036-4A93-91DC-4D987B5FE2BA",
              "versionEndExcluding": "6.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xm400:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9FC408A8-903F-43A2-9D05-65AD4482FDBB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr500_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B9AF696-211F-4CAD-8A0E-402487E8DC50",
              "versionEndExcluding": "6.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr500:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "080E722F-FCD4-4967-86EE-151ADC5702E7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w700_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D8763BB9-5DDA-4817-BDA6-63983CD4BC67",
              "versionEndExcluding": "6.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w700:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D3033B1E-57A6-4AE3-A861-7047CF8EAD79",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_m-800_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B74BBB98-0146-467E-B77B-E2FA1ABF2ED5",
              "versionEndExcluding": "4.03",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_m-800:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFB9921A-5204-40A3-88AB-B7755F5C6875",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_s615_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B2345F75-2CD1-4014-8F90-36A4FB4CC3BE",
              "versionEndExcluding": "4.03",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E917CBBB-EF41-4113-B0CA-EB91889235E7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:softnet_profinet_io_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9831567D-6528-4ACA-99F9-1EC42CB4A90D",
              "versionEndExcluding": "14",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:softnet_profinet_io_firmware:14:-:*:*:*:*:*:*",
              "matchCriteriaId": "27BC04E4-8C6F-4A66-86C4-A8F793A10BDD",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:softnet_profinet_io:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E348069A-B809-4DF6-81E9-DC52C6E2C268",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:ie\\/pb-link_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8ED91175-0AF3-424A-8C49-43587BB95EAB",
              "versionEndExcluding": "3.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:ie\\/pb-link:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8D43C16C-0719-4648-903F-6CC0FFF1835A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:ie\\/as-i_link_pn_io_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7E909C1E-9329-4459-ACE3-AD906CD4A968",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:ie\\/as-i_link_pn_io:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "317863B6-0B71-4D03-83FE-FC59EBB5307C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_teleservice_adapter_ie_standard_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5C887573-8BE8-42CF-B35A-22F9311AC627",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_teleservice_adapter_ie_standard:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3A5A3F7E-D039-430F-89B0-6AB4FD2428D4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_teleservice_adapter_ie_basic_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "80D166A8-1EEC-42F4-8EAB-1747247A7A05",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_teleservice_adapter_ie_basic:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FFA520B6-5177-43E4-87C0-C215F79FE9B4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_teleservice_adapter_ie_advanced_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C8E76BDE-C7E9-4D6B-B5D9-A456516CD016",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_teleservice_adapter_ie_advanced_modem:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BF513598-C3FA-4555-8133-A7276DDAFAC8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sitop_psu8600_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5468C9FA-ADD9-4FD3-89FE-C3621F5CB0EC",
              "versionEndExcluding": "1.2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sitop_psu8600:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "55058209-8AE5-42AF-80D4-5A7A44307266",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:ups1600_profinet_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "54B85DBA-24CA-4F95-89A5-D53D5AC69B0E",
              "versionEndExcluding": "2.2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:ups1600_profinet:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "ECC84D6F-F5E0-47CF-B11E-1C43F866D972",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200al_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C9D0595-53CD-48C0-82E3-DB0B2EC17721",
              "versionEndExcluding": "1.0.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200al:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "34C17B00-34B5-4A15-9333-252BE2975F37",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200ecopn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3EE0B998-E408-408F-8F78-5E90F74E9C9B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200ecopn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0259EAE9-0CA0-49A5-A573-8339604A181B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200m_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "14E56570-5C20-40BD-BF0B-F6ED06AFC8F7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200m:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7037E46B-4FE5-4693-B6A6-B5AF7B652C4F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200mp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "55BE63B0-F44E-4FCD-B00C-77595BACC62E",
              "versionEndExcluding": "4.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200mp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "49DA8715-D671-4D8F-A870-E61960A5AFA4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200pro_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D054139B-BE36-4B34-88AE-BC487DCB1DCB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200pro:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F0CE2EC-9A73-4576-A389-A19893D47B0F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200s_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BB063929-AAB0-4FF8-BCA3-71BA80517B1A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200s:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A1EC40E7-F004-446C-B5C9-0AB9911105E0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200sp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E6BACBC9-7C60-4A41-B8C6-A5E46B568029",
              "versionEndExcluding": "4.1.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200sp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "691CA334-4394-4ED6-B417-F67FC92228AE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:pn\\/pn_coupler_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "32BD232D-A6BB-4D7B-BD00-1085D08D8A77",
              "versionEndExcluding": "4.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:pn\\/pn_coupler:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB2846BD-9DAB-44A2-87C9-39E3ACFE03FA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0FE40195-DE5A-4B9C-9455-FAF92FF090D0",
              "versionEndExcluding": "4.1.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:4.1.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "9B339839-3D74-4E13-9EB6-24CA46F991A5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:dk_standard_ethernet_controller:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "53DF35F1-94FF-4D0B-9FA2-E8B0AFAEA5FF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:ek-ertec_200p_pn_io_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E9329BF4-D00A-4138-AA4C-93022002C0B9",
              "versionEndExcluding": "4.4.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:ek-ertec_200p_pn_io_firmware:4.4.0:-:*:*:*:*:*:*",
              "matchCriteriaId": "7863DDDC-D5CE-44FE-89C4-0E8A702A91A8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:ek-ertec_200p_pn_io:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E62802E3-AFA3-4023-9671-95C220397956",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:ek-ertec_200_pn_io_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8C46E084-9732-4920-86C2-3A91830CBCE3",
              "versionEndExcluding": "4.2.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:ek-ertec_200_pn_io_firmware:4.2.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "18C8B2FB-87C3-4DBB-9960-53FA545F26CB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:ek-ertec_200_pn_io:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "42D3FAF4-9B78-4EEF-8D80-17E9B98228D2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-200_smart_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "251EE4B2-F1C7-4ACF-B90D-4C0FE3D181E5",
              "versionEndExcluding": "2.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-200_smart:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "598EEFC9-5240-4011-9017-A9557585AA19",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-300_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4C096137-C1E3-4D19-87A9-BEB7A081DD1E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-300:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7EFD4E99-5C66-443F-8B6F-FA01C895DE78",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-400_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2570E321-C28E-46FA-8693-1230B3B5FD1B",
              "versionEndExcluding": "6.0.6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-400:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8F97B67B-4516-4AD9-B33C-7F480EE0DB4D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "582B49BD-4565-4D19-BBE6-A193BDFCE8B0",
              "versionEndExcluding": "4.2.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EC545350-FD53-4B2E-886F-E20F12260C9B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D24953B-B3DF-4150-810C-64A94A55E829",
              "versionEndExcluding": "2.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "30DDEA9B-E1BF-4572-8E12-D13C54603E77",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_software_controller_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E696D071-8601-40AA-BAF5-1452940E1D6E",
              "versionEndExcluding": "2.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_software_controller:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE4D4D21-9868-4FA3-89A8-1EEC473383EF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_winac_rtx_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "80BDBB38-20D2-48C3-8B58-62C2D8CC00B8",
              "versionEndExcluding": "2010",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_winac_rtx_firmware:2010:-:*:*:*:*:*:*",
              "matchCriteriaId": "EA59D713-F342-4CDA-BDC8-108352D385DA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_winac_rtx:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA5ADAB0-3985-4933-8CDD-D1546D8271CC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sirius_act_3su1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4E36412A-1AAB-42D1-B0B4-7A7BBF3CB317",
              "versionEndExcluding": "1.1.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sirius_act_3su1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8582A3E8-C05E-4D0B-851D-8C3181ED61CC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sirius_soft_starter_3rw44_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F84A65E6-4672-4B62-826E-6FAAE0B4A89D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sirius_soft_starter_3rw44_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CBB058FA-3E70-4489-AAB1-0CB7EF16A2E7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sirius_motor_starter_m200d_profinet_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3D42184E-8998-4C40-9612-5C9DE193CC06",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sirius_motor_starter_m200d_profinet:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BA5CB62E-04B7-4DD3-AA06-EB4A4FA58E54",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simocode_pro_v_profinet_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "98FDB53A-8F5D-46AA-9366-F6480B12D744",
              "versionEndExcluding": "2.0.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simocode_pro_v_profinet:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "352651A0-F7CE-4689-8597-15F3764707A9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_dcm_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FD2943F3-C46C-462E-9062-EE7B3E56CF72",
              "versionEndExcluding": "1.4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_dcm_firmware:1.4:-:*:*:*:*:*:*",
              "matchCriteriaId": "975EFBBB-33E1-4D04-9E06-93553D45539C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_dcm_firmware:1.4:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "99A0D811-2751-420E-AD85-B6EC777C8CAE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_dcm:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A1A43D34-ECA3-4330-B85F-02BDD1D22149",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_dcp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5D7A7140-62A2-434F-AB79-1D47C918F1FE",
              "versionEndExcluding": "1.2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_dcp_firmware:1.2:-:*:*:*:*:*:*",
              "matchCriteriaId": "A2B61A79-C2B0-4C3D-A63C-B20FF78B2981",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_dcp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B75F50CA-7371-4BC7-8D8A-13F8BC69E4EB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_g110m_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "775C90BB-C026-435C-889A-517EF85656C5",
              "versionEndExcluding": "4.7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_g110m_firmware:4.7:-:*:*:*:*:*:*",
              "matchCriteriaId": "CAA92AC6-7DA0-418D-A13F-69268DFD7966",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_g110m:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D61D3E9C-1346-4354-BCD9-B02F67500C41",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_g120\\(c\\/p\\/d\\)_w._pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "413AA7BE-CFE1-49DB-965F-1BD50D61F82F",
              "versionEndExcluding": "4.7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_g120\\(c\\/p\\/d\\)_w._pn_firmware:4.7:-:*:*:*:*:*:*",
              "matchCriteriaId": "82B4BE4B-3AE5-4039-B18D-A5DE3F1DDEF8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_g120\\(c\\/p\\/d\\)_w._pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0EE820D5-16B2-4565-9D83-AF018C08B5E5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_g130_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B3B0706-47CD-43FB-8E3A-7EEEF020AFBA",
              "versionEndExcluding": "4.7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_g130_firmware:4.7:-:*:*:*:*:*:*",
              "matchCriteriaId": "1D36CF8D-6DA4-49ED-9EF1-F96292F671EE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_g130:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "373DBE44-AC28-4D04-93BB-35CD8C60E899",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_g150_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AC731378-CB83-4C15-BC6A-5A86DF9B62F1",
              "versionEndExcluding": "4.7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_g150_firmware:4.7:-:*:*:*:*:*:*",
              "matchCriteriaId": "51A78A0B-5D75-418A-98AC-6EBF50D89A8A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_g150:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2296CA65-0E89-4BCB-8003-E7212BF1F585",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics__s110_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7143613F-4627-4F62-8F1B-E64CCB20F3D1",
              "versionEndExcluding": "4.4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics__s110_pn_firmware:4.4:-:*:*:*:*:*:*",
              "matchCriteriaId": "B428560B-2CAC-4A63-B677-724D95E12023",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:_s110_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "23B97849-01A7-4A8F-84DD-D25CF84D010B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "77A0BE57-1A9A-4564-9C53-CF47DEEF7991",
              "versionEndExcluding": "4.7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:4.7:-:*:*:*:*:*:*",
              "matchCriteriaId": "376556D0-1AE2-4F80-B3CE-C0251E35C326",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E5A824BD-935F-4E53-8313-C5544B0489C7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_s150_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "772FF972-2193-4639-B454-F92762E49C39",
              "versionEndExcluding": "4.7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_s150_firmware:4.7:-:*:*:*:*:*:*",
              "matchCriteriaId": "EE2B31F0-D45F-4B42-95D2-540C68C5F3DE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_s150:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0D48682C-A39D-4A09-B904-50FA64A9D2A5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_v90_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8EE54303-4FDA-42C7-B33B-BA884CD31339",
              "versionEndExcluding": "1.01",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_v90_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D870F289-F2BC-4105-A8F0-30E47CDE9FEF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simotion_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "92A7198A-D6C5-4FBF-8860-5C8EA864718B",
              "versionEndExcluding": "4.5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simotion_firmware:4.5:-:*:*:*:*:*:*",
              "matchCriteriaId": "B5DA6BF7-ECB8-47F1-A791-E65CFF89A608",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simotion:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "879CF09E-4735-4A73-8E7B-215F2701F7E0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinumerik_828d_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "71CD07D8-ECED-47EF-B2BC-0585F9BB00C1",
              "versionEndExcluding": "4.5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinumerik_828d_firmware:4.5:-:*:*:*:*:*:*",
              "matchCriteriaId": "AEB948AA-7BD7-4A0F-B86E-38ECD722C086",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinumerik_828d:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7D97047C-9772-4AEB-B993-131EBBAE33BA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinumerik_840d_sl_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "28E3AB24-86B4-485D-8D3A-131E5C7F0108",
              "versionEndExcluding": "4.5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinumerik_840d_sl_firmware:4.5:-:*:*:*:*:*:*",
              "matchCriteriaId": "40AC387B-B799-4A34-8C9E-73D05B86801D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinumerik_840d_sl:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "765286DF-07EC-4C7A-AB8C-09559CD977EA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CE53BC8E-CDA7-476A-87CA-532F365C79A7",
              "versionEndExcluding": "15.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3BCFE761-35C9-43EF-85BC-E8083B9F75CB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_multi_panels:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A1150AED-CDBE-492C-95FF-3E02B3B447F1",
              "versionEndExcluding": "15.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_multi_panels:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1AAE6A83-737B-47A9-86BB-652C7F6A8013",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_mobile_panels:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "42E8D21B-9CF4-4C2E-B33C-212BA29C7124",
              "versionEndExcluding": "15.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_mobile_panels:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "55E03180-BE77-4A22-A6C1-FE90B9760570",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-1_irc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "02610368-4B97-4B3F-8592-64CF8F65D8AD",
              "versionEndExcluding": "2.1.82",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-1_irc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "61E7964A-E7A4-4CDE-B376-5BBEC5F00A73",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-1_iec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BE5003DA-5488-47C1-B442-9137E849FDD5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-1_iec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFE96226-A2DF-4A9E-8CBB-8D7CF328E404",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-1_dnp3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FCF9D803-FF47-4400-B2C4-1F4EE28E5AA8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-1_dnp3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FFBFB96-1A35-4724-831B-68E3A9C32921",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_dk-1604_pn_io_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "65EDC583-1BCE-4787-820F-39DBD280DADF",
              "versionEndExcluding": "2.7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_dk-1604_pn_io:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "568ED124-AEE8-4BDC-BB89-0F8F83BA7537",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_tdc_cpu555_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D87643C3-6525-4CBD-BC0C-6B4DC30C8642",
              "versionEndExcluding": "1.1.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_tdc_cpu555:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AE6AB995-D67B-43E5-B8FF-97C38D20CB10",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_tdc_cp51m1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5C936A7A-1AF9-44E4-9CEC-0694A424616B",
              "versionEndExcluding": "1.1.8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_tdc_cp51m1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8DA1E7C4-6352-41A4-8A94-C24DDB456572",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_gh150_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D3F052D2-B537-4BF9-AF05-60107FDE0BEA",
              "versionEndExcluding": "4.7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_gh150_firmware:4.7:-:*:*:*:*:*:*",
              "matchCriteriaId": "96C7E194-617D-4593-B544-10AEFF59CCA5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BF977545-395A-4C34-BB22-A1047B5B6E85",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_gl150_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3653DA37-DB23-41E0-8CE8-838E384AA40A",
              "versionEndExcluding": "4.8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_gl150_firmware:4.8:-:*:*:*:*:*:*",
              "matchCriteriaId": "0F86A334-10F9-4DFB-A421-CBCAFD86C8C2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DED7F33B-D475-4232-8683-48554A6729F7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_gm150_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1BF93390-E65B-434E-9891-271DF7D11F47",
              "versionEndExcluding": "4.7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_gm150_firmware:4.7:-:*:*:*:*:*:*",
              "matchCriteriaId": "55F6B737-7237-4D38-A0F0-9EFCE76DC9C4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DD76CFB0-B5D7-40DC-8D14-FC9C9BACF3CD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_sl150_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FD67D30A-8681-41AE-B248-7E50BA1B9FC8",
              "versionEndExcluding": "4.8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_sl150_firmware:4.8:-:*:*:*:*:*:*",
              "matchCriteriaId": "FCC0EE8B-1088-46B6-992A-B8E12A7B7DC2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C6619B0F-7CDC-40A6-89B2-C6067AF45214",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_sm120_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "31393A1B-4DBC-476D-875E-463B4B887E1B",
              "versionEndExcluding": "4.8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_sm120_firmware:4.8:-:*:*:*:*:*:*",
              "matchCriteriaId": "0206F9F2-27C7-4D2F-817B-13F8FA31E547",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "444DD77F-DB65-4766-A89D-7A679B4CA1E1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:extension_unit_12_profinet_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E789146F-1FA4-42E4-B867-FD0F5A7316CA",
              "versionEndExcluding": "01.01.01",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:extension_unit_12_profinet:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1E0B32CC-8268-4B38-BBC7-51154882EC82",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:extension_unit_15_profinet_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "05B55989-A3E9-4AA1-A619-C75FEAA0B5DA",
              "versionEndExcluding": "01.01.01",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:extension_unit_15_profinet:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DA05435D-9A52-4D43-BE74-7D4C6C156AC6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:extension_unit_19_profinet_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "52156691-1368-4C77-98A7-EA63089091C5",
              "versionEndExcluding": "01.01.01",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:extension_unit_19_profinet:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5EE8B9B8-3C49-4296-9BC0-7E030878D479",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:extension_unit_22_profinet_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EC052323-2E00-415D-847A-66F77AD5C3FD",
              "versionEndExcluding": "01.01.01",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:extension_unit_22_profinet:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8F884CAF-D152-4318-B49B-0D68936D2BD9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1242-7_gprs_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F4E035CB-0F76-47C0-B2C7-93AFA8A7B38B",
              "versionEndExcluding": "2.1.82",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1242-7_gprs:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C6AEC7D6-7E5E-4CFF-99C8-7FBADA2479D5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-7_lte\\/us_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E4CEE93A-9641-424B-AF55-2C550CA568F2",
              "versionEndExcluding": "2.1.82",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-7_lte\\/us:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "00DDA679-D761-4986-A0A0-4C00178DF0B5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-8_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7D21A891-321B-42A3-8173-8E0743AEDD65",
              "versionEndExcluding": "2.1.82",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-8:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE0116F3-67FA-4129-B1FF-023774D179AF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1626_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "71BAF32C-35EA-4704-B75D-9EED01F8264B",
              "versionEndExcluding": "1.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1626:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "581EA284-EDD6-4EA5-96B2-67904D1D9DC7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected."
    },
    {
      "lang": "es",
      "value": "Los paquetes de difusi\u00f3n PROFINET DCP especialmente elaborados podr\u00edan causar una condici\u00f3n de denegaci\u00f3n de servicio de los productos afectados en un segmento Ethernet local (capa 2). Se requiere la interacci\u00f3n humana para recuperar los sistemas. Las interfaces PROFIBUS no est\u00e1n afectadas"
    }
  ],
  "id": "CVE-2017-2680",
  "lastModified": "2024-11-21T03:23:57.563",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "ADJACENT_NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 6.1,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 6.5,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "productcert@siemens.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "ADJACENT",
          "automatable": "NOT_DEFINED",
          "availabilityRequirements": "NOT_DEFINED",
          "baseScore": 7.1,
          "baseSeverity": "HIGH",
          "confidentialityRequirements": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirements": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubsequentSystemAvailability": "NOT_DEFINED",
          "modifiedSubsequentSystemConfidentiality": "NOT_DEFINED",
          "modifiedSubsequentSystemIntegrity": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnerableSystemAvailability": "NOT_DEFINED",
          "modifiedVulnerableSystemConfidentiality": "NOT_DEFINED",
          "modifiedVulnerableSystemIntegrity": "NOT_DEFINED",
          "privilegesRequired": "NONE",
          "providerUrgency": "NOT_DEFINED",
          "recovery": "NOT_DEFINED",
          "safety": "NOT_DEFINED",
          "subsequentSystemAvailability": "NONE",
          "subsequentSystemConfidentiality": "NONE",
          "subsequentSystemIntegrity": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnerabilityResponseEffort": "NOT_DEFINED",
          "vulnerableSystemAvailability": "HIGH",
          "vulnerableSystemConfidentiality": "NONE",
          "vulnerableSystemIntegrity": "NONE"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2017-05-11T01:29:05.400",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/98369"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securitytracker.com/id/1038463"
    },
    {
      "source": "productcert@siemens.com",
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-284673.html"
    },
    {
      "source": "productcert@siemens.com",
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html"
    },
    {
      "source": "productcert@siemens.com",
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-546832.html"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-284673.pdf"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-023-02"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Broken Link"
      ],
      "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/98369"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securitytracker.com/id/1038463"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-284673.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-546832.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-284673.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-023-02"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Broken Link"
      ],
      "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-400"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-400"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

cve-2017-2680
Vulnerability from cvelistv5
Published
2017-05-11 01:00
Modified
2024-09-10 09:33
Summary
Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected.
Impacted products
Vendor Product Version
Siemens Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 Version: All versions < V4.2.1 Patch03
Siemens Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P Version: All versions < V4.4.0 Patch01
Siemens Extension Unit 12" PROFINET Version: All versions < V01.01.01
Siemens Extension Unit 15" PROFINET Version: All versions < V01.01.01
Siemens Extension Unit 19" PROFINET Version: All versions < V01.01.01
Siemens Extension Unit 22" PROFINET Version: All versions < V01.01.01
Siemens IE/AS-i Link PN IO Version: All versions
Siemens IE/PB-Link (incl. SIPLUS NET variants) Version: All versions < V3.0
Siemens SCALANCE M-800 family (incl. S615, MUM-800 and RM1224) Version: All versions < V4.03
Siemens SCALANCE W-700 IEEE 802.11n family Version: All versions < V6.1
Siemens SCALANCE X-200 family (incl. SIPLUS NET variants) Version: All versions < V5.2.2
Siemens SCALANCE X-200IRT family (incl. SIPLUS NET variants) Version: All versions < V5.4.0
Siemens SCALANCE X-300 family (incl. X408 and SIPLUS NET variants) Version: All versions < V4.1.0
Siemens SCALANCE X408 family Version: All versions < V4.1.0
Siemens SCALANCE X414 Version: All versions < V3.10.2
Siemens SCALANCE XM-400 family Version: All versions < V6.1
Siemens SCALANCE XR-500 family Version: All versions < V6.1
Siemens SIMATIC CM 1542-1 Version: All versions < V2.0
Siemens SIMATIC CM 1542SP-1 Version: All versions < V1.0.15
Siemens SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) Version: All versions < V2.1.82
Siemens SIMATIC CP 1243-1 (incl. SIPLUS variants) Version: All versions < V2.1.82
Siemens SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) Version: 0   < *
Siemens SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) Version: All versions
Siemens SIMATIC CP 1243-7 LTE US Version: All versions < V2.1.82
Siemens SIMATIC CP 1243-8 IRC Version: All versions < V2.1.82
Siemens SIMATIC CP 1243-8 IRC Version: All versions < V2.1.82
Siemens SIMATIC CP 1542SP-1 IRC (incl. SIPLUS variants) Version: All versions < V1.0.15
Siemens SIMATIC CP 1543-1 (incl. SIPLUS variants) Version: All versions < V2.1
Siemens SIMATIC CP 1543SP-1 (incl. SIPLUS variants) Version: All versions < V1.0.15
Siemens SIMATIC CP 1604 Version: All versions < V2.7
Siemens SIMATIC CP 1616 Version: All versions < V2.7
Siemens SIMATIC CP 1626 Version: All versions < V1.1
Siemens SIMATIC CP 343-1 (incl. SIPLUS variants) Version: All versions < V3.1.3
Siemens SIMATIC CP 343-1 Advanced (incl. SIPLUS variants) Version: All versions
Siemens SIMATIC CP 343-1 Lean (incl. SIPLUS variants) Version: All versions < V3.1.3
Siemens SIMATIC CP 443-1 (incl. SIPLUS variants) Version: All versions < V3.2.17
Siemens SIMATIC CP 443-1 Advanced (incl. SIPLUS variants) Version: All versions < V3.2.17
Siemens SIMATIC CP 443-1 OPC UA Version: All versions
Siemens SIMATIC DK-16xx PN IO Version: All versions < V2.7
Siemens SIMATIC ET 200AL IM 157-1 PN Version: 0   < V1.0.2
Siemens SIMATIC ET 200M (incl. SIPLUS variants) Version: All versions
Siemens SIMATIC ET 200MP IM 155-5 PN BA Version: 0   < V4.0.1
Siemens SIMATIC ET 200MP IM 155-5 PN HF Version: 0   < V4.2.0
Siemens SIMATIC ET 200MP IM 155-5 PN ST Version: 0   < V4.1.0
Siemens SIMATIC ET 200pro IM 154-3 PN HF Version: 0   < *
Siemens SIMATIC ET 200pro IM 154-4 PN HF Version: 0   < *
Siemens SIMATIC ET 200SP IM 155-6 PN BA Version: 0   < *
Siemens SIMATIC ET 200SP IM 155-6 PN HF Version: 0   < V4.2.0
Siemens SIMATIC ET 200SP IM 155-6 PN HS Version: 0   < V4.0.1
Siemens SIMATIC ET 200SP IM 155-6 PN ST Version: 0   < V4.1.0
Siemens SIMATIC ET 200SP IM 155-6 PN ST BA Version: 0   < V4.1.0
Siemens SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12 Version: All versions
Siemens SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12 Version: All versions
Siemens SIMATIC ET200ecoPN, 4AO U/I 4xM12 Version: All versions
Siemens SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12 Version: All versions
Siemens SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12 Version: All versions
Siemens SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12 Version: All versions
Siemens SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12 Version: All versions
Siemens SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12 Version: All versions
Siemens SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12 Version: All versions
Siemens SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12 Version: All versions
Siemens SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12 Version: All versions
Siemens SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12 Version: All versions
Siemens SIMATIC ET200ecoPN: IO-Link Master Version: All versions
Siemens SIMATIC ET200S (incl. SIPLUS variants) Version: All versions
Siemens SIMATIC HMI Comfort Panels, HMI Multi Panels, HMI Mobile Panels (incl. SIPLUS variants) Version: All versions < V15.1
Siemens SIMATIC MV420 SR-B Version: 0   < V7.0.6
Siemens SIMATIC MV420 SR-B Body Version: 0   < V7.0.6
Siemens SIMATIC MV420 SR-P Version: 0   < V7.0.6
Siemens SIMATIC MV420 SR-P Body Version: 0   < V7.0.6
Siemens SIMATIC MV440 HR Version: 0   < V7.0.6
Siemens SIMATIC MV440 SR Version: 0   < V7.0.6
Siemens SIMATIC MV440 UR Version: 0   < V7.0.6
Siemens SIMATIC PN/PN Coupler (incl. SIPLUS NET variants) Version: All versions < V4.0
Siemens SIMATIC RF650R Version: All versions < V3.0
Siemens SIMATIC RF680R Version: All versions < V3.0
Siemens SIMATIC RF685R Version: All versions < V3.0
Siemens SIMATIC S7-1200 CPU family (incl. SIPLUS variants) Version: All versions < V4.2.1
Siemens SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) Version: All versions < V2.1
Siemens SIMATIC S7-1500 Software Controller Version: All versions < V2.1
Siemens SIMATIC S7-200 SMART Version: All versions < V2.3
Siemens SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) Version: 0   < V3.X.14
Siemens SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) Version: 0   < V6.0.7
Siemens SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants) Version: 0   < V6.0.6
Siemens SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) Version: 0   < V7.0.2
Siemens SIMATIC S7-410 CPU family (incl. SIPLUS variants) Version: All versions < V8.2
Siemens SIMATIC TDC CP51M1 Version: 0   < V1.1.8
Siemens SIMATIC TDC CPU555 Version: 0   < V1.1.1
Siemens SIMATIC Teleservice Adapter IE Advanced Version: All versions
Siemens SIMATIC Teleservice Adapter IE Basic Version: All versions
Siemens SIMATIC Teleservice Adapter IE Standard Version: All versions
Siemens SIMATIC WinAC RTX 2010 Version: All versions < V2010 SP3
Siemens SIMATIC WinAC RTX F 2010 Version: All versions < V2010 SP3
Siemens SIMOCODE pro V PROFINET (incl. SIPLUS variants) Version: All versions < V2.0.0
Siemens SIMOTION Version: All versions < V4.5 HF1
Siemens SIMOTION D4xx V4.4 for SINAMICS SM150i-2 w. PROFINET (incl. SIPLUS variants) Version: All versions < V4.4 HF26
Siemens SINAMICS DCM w. PN Version: All versions < V1.4 SP1 HF5
Siemens SINAMICS DCP w. PN Version: All versions < V1.2 HF1
Siemens SINAMICS G110M w. PN Version: All versions < V4.7 SP6 HF3
Siemens SINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants) Version: All versions < V4.7 SP6 HF3
Siemens SINAMICS G130 V4.7 w. PN Version: All versions < V4.7 HF27
Siemens SINAMICS G130 V4.8 w. PN Version: All versions < V4.8 HF4
Siemens SINAMICS G150 V4.7 w. PN Version: V4.7: All versions < V4.7 HF27
Siemens SINAMICS G150 V4.8 w. PN Version: All versions < V4.8 HF4
Siemens SINAMICS GH150 V4.7 w. PROFINET Version: All versions < V4.7 SP5 HF7
Siemens SINAMICS GL150 V4.7 w. PROFINET Version: All versions < V4.8 SP2
Siemens SINAMICS GM150 V4.7 w. PROFINET Version: All versions < V4.7 HF31
Siemens SINAMICS S110 w. PN Version: All versions < V4.4 SP3 HF5
Siemens SINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants) Version: All versions < V4.7
Siemens SINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants) Version: All versions
Siemens SINAMICS S120 V4.7 w. PN (incl. SIPLUS variants) Version: All versions < V4.7 HF27
Siemens SINAMICS S120 V4.8 w. PN (incl. SIPLUS variants) Version: All versions < V4.8 HF4
Siemens SINAMICS S150 V4.7 w. PN Version: All versions < V4.7 HF27
Siemens SINAMICS S150 V4.8 w. PN Version: All versions < V4.8 HF4
Siemens SINAMICS SL150 V4.7.0 w. PROFINET Version: All versions < V4.7 HF30
Siemens SINAMICS SL150 V4.7.4 w. PROFINET Version: All versions < V4.8 SP2
Siemens SINAMICS SL150 V4.7.5 w. PROFINET Version: All versions < V4.8 SP2
Siemens SINAMICS SM120 V4.7 w. PROFINET Version: All versions < V4.8 SP2
Siemens SINAMICS V90 w. PN Version: All versions < V1.01
Siemens SINUMERIK 828D V4.5 and prior Version: All versions < V4.5 SP6 HF2
Siemens SINUMERIK 828D V4.7 Version: All versions < V4.7 SP4 HF1
Siemens SINUMERIK 840D sl V4.5 and prior Version: All versions < V4.5 SP6 HF2
Siemens SINUMERIK 840D sl V4.7 Version: All versions < V4.7 SP4 HF1
Siemens SIPLUS ET 200MP IM 155-5 PN HF Version: 0   < V4.2.0
Siemens SIPLUS ET 200MP IM 155-5 PN HF Version: 0   < V4.2.0
Siemens SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL Version: 0   < V4.2.0
Siemens SIPLUS ET 200MP IM 155-5 PN ST Version: 0   < V4.1.0
Siemens SIPLUS ET 200MP IM 155-5 PN ST TX RAIL Version: 0   < V4.1.0
Siemens SIPLUS ET 200SP IM 155-6 PN HF Version: 0   < V4.2.0
Siemens SIPLUS ET 200SP IM 155-6 PN HF Version: 0   < V4.2.0
Siemens SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL Version: 0   < V4.2.0
Siemens SIPLUS ET 200SP IM 155-6 PN ST Version: 0   < V4.1.0
Siemens SIPLUS ET 200SP IM 155-6 PN ST BA Version: 0   < V4.1.0
Siemens SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL Version: 0   < V4.1.0
Siemens SIPLUS ET 200SP IM 155-6 PN ST TX RAIL Version: 0   < V4.1.0
Siemens SIRIUS ACT 3SU1 interface module PROFINET Version: All versions < V1.1.0
Siemens SIRIUS Motor Starter M200D PROFINET Version: All versions
Siemens SIRIUS Soft Starter 3RW44 PN Version: All versions
Siemens SITOP PSU8600 PROFINET Version: All versions < V1.2.0
Siemens SITOP UPS1600 PROFINET (incl. SIPLUS variants) Version: All versions < V2.2.0
Siemens Softnet PROFINET IO for PC-based Windows systems Version: All versions < V14 SP1
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2017-2680",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-09T13:26:04.237652Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-09T13:26:15.327Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T14:02:07.270Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "1038463",
            "tags": [
              "vdb-entry",
              "x_refsource_SECTRACK",
              "x_transferred"
            ],
            "url": "http://www.securitytracker.com/id/1038463"
          },
          {
            "name": "98369",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/98369"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-023-02"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-284673.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-284673.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-546832.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.1 Patch04"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.2.1 Patch03"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4.0 Patch01"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Extension Unit 12\" PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V01.01.01"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Extension Unit 15\" PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V01.01.01"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Extension Unit 19\" PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V01.01.01"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Extension Unit 22\" PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V01.01.01"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IE/AS-i Link PN IO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IE/PB-Link (incl. SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M-800 family (incl. S615, MUM-800 and RM1224)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.03"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W-700 IEEE 802.11n family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X-200 family (incl. SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X-200IRT family (incl. SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.4.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X-300 family (incl. X408 and SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X408 family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X414",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.10.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM-400 family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR-500 family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CM 1542-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CM 1542SP-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.0.15"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1242-7 V2 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1.82"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1.82"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-7 LTE US",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1.82"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-8 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1.82"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-8 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1.82"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1542SP-1 IRC (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.0.15"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1543-1 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1543SP-1 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.0.15"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1604",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1616",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1626",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 343-1 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.1.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 343-1 Advanced (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 343-1 Lean (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.1.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1 Advanced (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1 OPC UA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC DK-16xx PN IO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200AL IM 157-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V1.0.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200M (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200MP IM 155-5 PN BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.0.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200MP IM 155-5 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200MP IM 155-5 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM 154-3 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM 154-4 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN HS",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.0.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN ST BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 4AO U/I 4xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN: IO-Link Master",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200S (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC HMI Comfort Panels, HMI Multi Panels, HMI Mobile Panels (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV420 SR-B",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV420 SR-B Body",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV420 SR-P",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV420 SR-P Body",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV440 HR",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV440 SR",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV440 UR",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PN/PN Coupler (incl. SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC RF650R",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC RF680R",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC RF685R",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 Software Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-200 SMART",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.X.14",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0.7",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-410 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC TDC CP51M1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V1.1.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC TDC CPU555",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V1.1.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Teleservice Adapter IE Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Teleservice Adapter IE Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Teleservice Adapter IE Standard",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinAC RTX 2010",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2010 SP3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinAC RTX F 2010",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2010 SP3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOCODE pro V PROFINET (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTION",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.5 HF1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTION D4xx V4.4 for SINAMICS SM150i-2 w. PROFINET (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4 HF26"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS DCM w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.4 SP1 HF5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS DCP w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.2 HF1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G110M w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 SP6 HF3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 SP6 HF3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G130 V4.7 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 HF27"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G130 V4.8 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 HF4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G150 V4.7 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "V4.7: All versions \u003c V4.7 HF27"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G150 V4.8 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 HF4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS GH150 V4.7 w. PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 SP5 HF7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS GL150 V4.7 w. PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 SP2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS GM150 V4.7 w. PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 HF31"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S110 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4 SP3 HF5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 V4.7 w. PN (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 HF27"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 V4.8 w. PN (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 HF4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S150 V4.7 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 HF27"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S150 V4.8 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 HF4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS SL150 V4.7.0 w. PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 HF30"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS SL150 V4.7.4 w. PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 SP2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS SL150 V4.7.5 w. PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 SP2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS SM120 V4.7 w. PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 SP2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS V90 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.01"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINUMERIK 828D V4.5 and prior",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.5 SP6 HF2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINUMERIK 828D V4.7",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 SP4 HF1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINUMERIK 840D sl V4.5 and prior",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.5 SP6 HF2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINUMERIK 840D sl V4.7",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 SP4 HF1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN ST TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIRIUS ACT 3SU1 interface module PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.1.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIRIUS Motor Starter M200D PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIRIUS Soft Starter 3RW44 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SITOP PSU8600 PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SITOP UPS1600 PROFINET (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Softnet PROFINET IO for PC-based Windows systems",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14 SP1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-400",
              "description": "CWE-400: Uncontrolled Resource Consumption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-10T09:33:18.492Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "name": "1038463",
          "tags": [
            "vdb-entry",
            "x_refsource_SECTRACK"
          ],
          "url": "http://www.securitytracker.com/id/1038463"
        },
        {
          "name": "98369",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/98369"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-023-02"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-284673.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-284673.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-546832.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2017-2680",
    "datePublished": "2017-05-11T01:00:00",
    "dateReserved": "2016-12-01T00:00:00",
    "dateUpdated": "2024-09-10T09:33:18.492Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2017-2681
Vulnerability from cvelistv5
Published
2017-05-11 10:00
Modified
2024-09-10 09:33
Summary
Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected.
Impacted products
Vendor Product Version
Siemens Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 Version: All versions < V4.2.1 Patch03
Siemens Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P Version: All versions < V4.4.0 Patch01
Siemens IE/AS-i Link PN IO Version: All versions
Siemens IE/PB-Link (incl. SIPLUS NET variants) Version: All versions < V3.0
Siemens SCALANCE M-800 family (incl. S615, MUM-800 and RM1224) Version: All versions < V4.03
Siemens SCALANCE W-700 IEEE 802.11n family Version: All versions < V6.1
Siemens SCALANCE X-200 family (incl. SIPLUS NET variants) Version: All versions < V5.2.2
Siemens SCALANCE X-200IRT family (incl. SIPLUS NET variants) Version: All versions < V5.4.0
Siemens SCALANCE X-300 family (incl. X408 and SIPLUS NET variants) Version: All versions < V4.1.0
Siemens SCALANCE X408 family Version: All versions < V4.1.0
Siemens SCALANCE X414 Version: All versions < V3.10.2
Siemens SCALANCE XM-400 family Version: All versions < V6.1
Siemens SCALANCE XR-500 family Version: All versions < V6.1
Siemens SIMATIC CM 1542-1 Version: All versions < V2.0
Siemens SIMATIC CM 1542SP-1 Version: All versions < V1.0.15
Siemens SIMATIC CP 1243-1 (incl. SIPLUS variants) Version: All versions < V2.1.82
Siemens SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) Version: 0   < *
Siemens SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) Version: All versions
Siemens SIMATIC CP 1243-8 IRC Version: All versions < V2.1.82
Siemens SIMATIC CP 1542SP-1 IRC (incl. SIPLUS variants) Version: All versions < V1.0.15
Siemens SIMATIC CP 1543-1 (incl. SIPLUS variants) Version: All versions < V2.1
Siemens SIMATIC CP 1543SP-1 (incl. SIPLUS variants) Version: All versions < V1.0.15
Siemens SIMATIC CP 1604 Version: All versions < V2.7
Siemens SIMATIC CP 1616 Version: All versions < V2.7
Siemens SIMATIC CP 343-1 (incl. SIPLUS variants) Version: All versions < V3.1.3
Siemens SIMATIC CP 343-1 Advanced (incl. SIPLUS variants) Version: All versions
Siemens SIMATIC CP 343-1 Lean (incl. SIPLUS variants) Version: All versions < V3.1.3
Siemens SIMATIC CP 443-1 (incl. SIPLUS variants) Version: All versions < V3.2.17
Siemens SIMATIC CP 443-1 Advanced (incl. SIPLUS variants) Version: All versions < V3.2.17
Siemens SIMATIC CP 443-1 OPC UA Version: All versions
Siemens SIMATIC DK-16xx PN IO Version: All versions < V2.7
Siemens SIMATIC ET 200AL IM 157-1 PN Version: 0   < V1.0.2
Siemens SIMATIC ET 200M (incl. SIPLUS variants) Version: All versions
Siemens SIMATIC ET 200MP IM 155-5 PN BA Version: 0   < V4.0.1
Siemens SIMATIC ET 200MP IM 155-5 PN HF Version: 0   < V4.2.0
Siemens SIMATIC ET 200MP IM 155-5 PN ST Version: 0   < V4.1.0
Siemens SIMATIC ET 200pro IM 154-3 PN HF Version: 0   < *
Siemens SIMATIC ET 200pro IM 154-4 PN HF Version: 0   < *
Siemens SIMATIC ET 200SP IM 155-6 PN BA Version: 0   < *
Siemens SIMATIC ET 200SP IM 155-6 PN HF Version: 0   < V4.2.0
Siemens SIMATIC ET 200SP IM 155-6 PN HS Version: 0   < V4.0.1
Siemens SIMATIC ET 200SP IM 155-6 PN ST Version: 0   < V4.1.0
Siemens SIMATIC ET 200SP IM 155-6 PN ST BA Version: 0   < V4.1.0
Siemens SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12 Version: All versions
Siemens SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12 Version: All versions
Siemens SIMATIC ET200ecoPN, 4AO U/I 4xM12 Version: All versions
Siemens SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12 Version: All versions
Siemens SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12 Version: All versions
Siemens SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12 Version: All versions
Siemens SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12 Version: All versions
Siemens SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12 Version: All versions
Siemens SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12 Version: All versions
Siemens SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12 Version: All versions
Siemens SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12 Version: All versions
Siemens SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12 Version: All versions
Siemens SIMATIC ET200ecoPN: IO-Link Master Version: All versions
Siemens SIMATIC ET200S (incl. SIPLUS variants) Version: All versions
Siemens SIMATIC HMI Comfort Panels, HMI Multi Panels, HMI Mobile Panels (incl. SIPLUS variants) Version: All versions < V15.1
Siemens SIMATIC MV420 SR-B Version: 0   < V7.0.6
Siemens SIMATIC MV420 SR-B Body Version: 0   < V7.0.6
Siemens SIMATIC MV420 SR-P Version: 0   < V7.0.6
Siemens SIMATIC MV420 SR-P Body Version: 0   < V7.0.6
Siemens SIMATIC MV440 HR Version: 0   < V7.0.6
Siemens SIMATIC MV440 SR Version: 0   < V7.0.6
Siemens SIMATIC MV440 UR Version: 0   < V7.0.6
Siemens SIMATIC PN/PN Coupler (incl. SIPLUS NET variants) Version: All versions < V4.0
Siemens SIMATIC RF650R Version: All versions < V3.0
Siemens SIMATIC RF680R Version: All versions < V3.0
Siemens SIMATIC RF685R Version: All versions < V3.0
Siemens SIMATIC S7-1200 CPU family (incl. SIPLUS variants) Version: All versions < V4.2.1
Siemens SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) Version: All versions < V2.1
Siemens SIMATIC S7-1500 Software Controller Version: All versions < V2.1
Siemens SIMATIC S7-200 SMART Version: All versions < V2.3
Siemens SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) Version: 0   < V3.X.14
Siemens SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) Version: 0   < V6.0.7
Siemens SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants) Version: 0   < V6.0.6
Siemens SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) Version: 0   < V7.0.2
Siemens SIMATIC S7-410 CPU family (incl. SIPLUS variants) Version: All versions < V8.2
Siemens SIMATIC TDC CP51M1 Version: 0   < V1.1.8
Siemens SIMATIC TDC CPU555 Version: 0   < V1.1.1
Siemens SIMATIC Teleservice Adapter IE Advanced Version: All versions
Siemens SIMATIC Teleservice Adapter IE Basic Version: All versions
Siemens SIMATIC Teleservice Adapter IE Standard Version: All versions
Siemens SIMATIC WinAC RTX 2010 Version: All versions < V2010 SP3
Siemens SIMATIC WinAC RTX F 2010 Version: All versions < V2010 SP3
Siemens SIMOCODE pro V PROFINET (incl. SIPLUS variants) Version: All versions < V2.0.0
Siemens SIMOTION Version: All versions < V4.5 HF1
Siemens SINAMICS DCM w. PN Version: All versions < V1.4 SP1 HF5
Siemens SINAMICS DCP w. PN Version: All versions < V1.2 HF1
Siemens SINAMICS G110M w. PN Version: All versions < V4.7 SP6 HF3
Siemens SINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants) Version: All versions < V4.7 SP6 HF3
Siemens SINAMICS G130 V4.7 w. PN Version: All versions < V4.7 HF27
Siemens SINAMICS G130 V4.8 w. PN Version: All versions < V4.8 HF4
Siemens SINAMICS G150 V4.7 w. PN Version: V4.7: All versions < V4.7 HF27
Siemens SINAMICS G150 V4.8 w. PN Version: All versions < V4.8 HF4
Siemens SINAMICS S110 w. PN Version: All versions < V4.4 SP3 HF5
Siemens SINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants) Version: All versions < V4.7
Siemens SINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants) Version: All versions
Siemens SINAMICS S120 V4.7 w. PN (incl. SIPLUS variants) Version: All versions < V4.7 HF27
Siemens SINAMICS S120 V4.8 w. PN (incl. SIPLUS variants) Version: All versions < V4.8 HF4
Siemens SINAMICS S150 V4.7 w. PN Version: All versions < V4.7 HF27
Siemens SINAMICS S150 V4.8 w. PN Version: All versions < V4.8 HF4
Siemens SINAMICS V90 w. PN Version: All versions < V1.01
Siemens SINUMERIK 828D V4.5 and prior Version: All versions < V4.5 SP6 HF2
Siemens SINUMERIK 828D V4.7 Version: All versions < V4.7 SP4 HF1
Siemens SINUMERIK 840D sl V4.5 and prior Version: All versions < V4.5 SP6 HF2
Siemens SINUMERIK 840D sl V4.7 Version: All versions < V4.7 SP4 HF1
Siemens SIPLUS ET 200MP IM 155-5 PN HF Version: 0   < V4.2.0
Siemens SIPLUS ET 200MP IM 155-5 PN HF Version: 0   < V4.2.0
Siemens SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL Version: 0   < V4.2.0
Siemens SIPLUS ET 200MP IM 155-5 PN ST Version: 0   < V4.1.0
Siemens SIPLUS ET 200MP IM 155-5 PN ST TX RAIL Version: 0   < V4.1.0
Siemens SIPLUS ET 200SP IM 155-6 PN HF Version: 0   < V4.2.0
Siemens SIPLUS ET 200SP IM 155-6 PN HF Version: 0   < V4.2.0
Siemens SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL Version: 0   < V4.2.0
Siemens SIPLUS ET 200SP IM 155-6 PN ST Version: 0   < V4.1.0
Siemens SIPLUS ET 200SP IM 155-6 PN ST BA Version: 0   < V4.1.0
Siemens SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL Version: 0   < V4.1.0
Siemens SIPLUS ET 200SP IM 155-6 PN ST TX RAIL Version: 0   < V4.1.0
Siemens SIRIUS ACT 3SU1 interface module PROFINET Version: All versions < V1.1.0
Siemens SIRIUS Motor Starter M200D PROFINET Version: All versions
Siemens SIRIUS Soft Starter 3RW44 PN Version: All versions
Siemens SITOP PSU8600 PROFINET Version: All versions < V1.2.0
Siemens SITOP UPS1600 PROFINET (incl. SIPLUS variants) Version: All versions < V2.2.0
Siemens Softnet PROFINET IO for PC-based Windows systems Version: All versions < V14 SP1
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2017-2681",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-23T20:22:19.045364Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-23T20:22:26.181Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T14:02:07.386Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "1038463",
            "tags": [
              "vdb-entry",
              "x_refsource_SECTRACK",
              "x_transferred"
            ],
            "url": "http://www.securitytracker.com/id/1038463"
          },
          {
            "name": "98369",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/98369"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.1 Patch04"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.2.1 Patch03"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4.0 Patch01"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IE/AS-i Link PN IO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IE/PB-Link (incl. SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M-800 family (incl. S615, MUM-800 and RM1224)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.03"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W-700 IEEE 802.11n family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X-200 family (incl. SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X-200IRT family (incl. SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.4.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X-300 family (incl. X408 and SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X408 family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X414",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.10.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM-400 family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR-500 family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CM 1542-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CM 1542SP-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.0.15"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1.82"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-8 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1.82"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1542SP-1 IRC (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.0.15"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1543-1 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1543SP-1 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.0.15"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1604",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1616",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 343-1 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.1.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 343-1 Advanced (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 343-1 Lean (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.1.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1 Advanced (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1 OPC UA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC DK-16xx PN IO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200AL IM 157-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V1.0.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200M (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200MP IM 155-5 PN BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.0.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200MP IM 155-5 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200MP IM 155-5 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM 154-3 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM 154-4 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN HS",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.0.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN ST BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 4AO U/I 4xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN: IO-Link Master",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200S (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC HMI Comfort Panels, HMI Multi Panels, HMI Mobile Panels (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV420 SR-B",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV420 SR-B Body",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV420 SR-P",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV420 SR-P Body",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV440 HR",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV440 SR",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV440 UR",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PN/PN Coupler (incl. SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC RF650R",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC RF680R",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC RF685R",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 Software Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-200 SMART",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.X.14",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0.7",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-410 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC TDC CP51M1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V1.1.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC TDC CPU555",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V1.1.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Teleservice Adapter IE Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Teleservice Adapter IE Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Teleservice Adapter IE Standard",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinAC RTX 2010",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2010 SP3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinAC RTX F 2010",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2010 SP3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOCODE pro V PROFINET (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTION",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.5 HF1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS DCM w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.4 SP1 HF5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS DCP w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.2 HF1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G110M w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 SP6 HF3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 SP6 HF3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G130 V4.7 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 HF27"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G130 V4.8 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 HF4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G150 V4.7 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "V4.7: All versions \u003c V4.7 HF27"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G150 V4.8 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 HF4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S110 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4 SP3 HF5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 V4.7 w. PN (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 HF27"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 V4.8 w. PN (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 HF4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S150 V4.7 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 HF27"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S150 V4.8 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 HF4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS V90 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.01"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINUMERIK 828D V4.5 and prior",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.5 SP6 HF2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINUMERIK 828D V4.7",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 SP4 HF1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINUMERIK 840D sl V4.5 and prior",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.5 SP6 HF2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINUMERIK 840D sl V4.7",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 SP4 HF1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN ST TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIRIUS ACT 3SU1 interface module PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.1.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIRIUS Motor Starter M200D PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIRIUS Soft Starter 3RW44 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SITOP PSU8600 PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SITOP UPS1600 PROFINET (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Softnet PROFINET IO for PC-based Windows systems",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14 SP1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-400",
              "description": "CWE-400: Uncontrolled Resource Consumption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-10T09:33:20.658Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "name": "1038463",
          "tags": [
            "vdb-entry",
            "x_refsource_SECTRACK"
          ],
          "url": "http://www.securitytracker.com/id/1038463"
        },
        {
          "name": "98369",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/98369"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2017-2681",
    "datePublished": "2017-05-11T10:00:00",
    "dateReserved": "2016-12-01T00:00:00",
    "dateUpdated": "2024-09-10T09:33:20.658Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

var-201705-3221
Vulnerability from variot

Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected. This vulnerability affects only SIMATIC HMI Multi Panels and HMI Mobile Panels, and S7-300/S7-400 devices. SIMATIC HMI is an industrial device from Siemens AG, Germany. The SIMATIC HMI panels are used for operator control and monitoring of machines and equipment. Multiple Siemens Products is prone to multiple denial-of-service vulnerabilities. Attackers can exploit these issues to cause a denial-of-service condition. Manual restart of the server is required to resume normal operation. A vulnerability has been identified in SIMATIC CP 343-1 Std (All versions), SIMATIC CP 343-1 Lean (All versions), SIMATIC CP 343-1 Adv (All versions), SIMATIC CP 443-1 Std (All versions < V3.2.17), SIMATIC CP 443-1 Adv (All versions < V3.2.17), SIMATIC CP 443-1 OPC-UA (All versions), SIMATIC CP 1243-1 (All versions < V2.1.82), SIMATIC CP 1243-1 IRC (All versions < V2.1.82), SIMATIC CP 1243-1 IEC (All versions), SIMATIC CP 1243-1 DNP3 (All versions), SIMATIC CM 1542-1 (All versions < V2.0), SIMATIC CM 1542SP-1 (All versions < V1.0.15), SIMATIC CP 1542SP-1 IRC (All versions < V1.0.15), SIMATIC CP 1543SP-1 (All versions < V1.0.15), SIMATIC CP 1543-1 (All versions < V2.1), SIMATIC RF650R (All versions < V3.0), SIMATIC RF680R (All versions < V3.0), SIMATIC RF685R (All versions < V3.0), SIMATIC CP 1616 (All versions < V2.7), SIMATIC CP 1604 (All versions < V2.7), SIMATIC DK-16xx PN IO (All versions < V2.7), SCALANCE X-200 (All versions < V5.2.2), SCALANCE X-200 IRT (All versions), SCALANCE X-300/X408 (All versions < V4.1.0), SCALANCE X414 (All versions < V3.10.2), SCALANCE XM400 (All versions < V6.1), SCALANCE XR500 (All versions < V6.1), SCALANCE W700 (All versions < V6.1), SCALANCE M-800, S615 (All versions < V4.03), Softnet PROFINET IO for PC-based Windows systems (All versions < V14 SP1), IE/PB-Link (All versions < V3.0), IE/AS-i Link PN IO (All versions), SIMATIC Teleservice Adapter Standard Modem, IE Basic, IE Advanced (All versions), SITOP PSU8600 PROFINET (All versions < V1.2.0), SITOP UPS1600 PROFINET (All versions < V2.2.0), SIMATIC ET 200AL (All versions < V1.0.2), SIMATIC ET 200ecoPN (All versions), SIMATIC ET 200M (All versions), SIMATIC ET 200MP IM155-5 PN BA (All versions < V4.0.1), SIMATIC ET 200MP IM155-5 PN ST (All versions < V4.1), SIMATIC ET 200MP (except IM155-5 PN BA and IM155-5 PN ST) (All versions), SIMATIC ET 200pro (All versions), SIMATIC ET 200S (All versions), SIMATIC ET 200SP IM155-6 PN ST (All versions < V4.1.0), SIMATIC ET 200SP (except IM155-6 PN ST) (All versions), SIMATIC PN/PN Coupler (All versions < V4.0), Development/Evaluation Kit DK Standard Ethernet Controller (All versions < V4.1.1 Patch04), Development/Evaluation Kit EK-ERTEC 200P (All versions < V4.4.0 Patch01), Development/Evaluation Kit EK-ERTEC 200 (All versions < V4.2.1 Patch03), SIMATIC S7-200 SMART (All versions < V2.3), SIMATIC S7-300 incl. F and T (All versions < V3.X.14), SIMATIC S7-400 PN/DP V6 Incl. F (All versions < V6.0.6), SIMATIC S7-400-H V6 (All versions < V6.0.7), SIMATIC S7-400 PN/DP V7 Incl. F (All versions < V7.0.2), SIMATIC S7-410 (All versions < V8.2), SIMATIC S7-1200 incl. F (All versions < V4.2.1), SIMATIC S7-1500 incl. F, T, and TF (All versions < V2.1), SIMATIC S7-1500 Software Controller incl. F (All versions < V2.1), SIMATIC WinAC RTX 2010 incl. F (All versions), SIRIUS ACT 3SU1 interface module PROFINET (All versions), SIRIUS Soft Starter 3RW44 PN (All versions), SIRIUS Motor Starter M200D PROFINET (All versions), SIMOCODE pro V PROFINET (All versions < V2.0.0), SINAMICS DCM w. PN (All versions < V1.4 SP1 HF5), SINAMICS DCP w. PN (All versions < V1.2 HF 1), SINAMICS G110M w. PN (All versions < V4.7 SP6 HF3), SINAMICS G120(C/P/D) w. PN (All versions < V4.7 SP6 HF3), SINAMICS G130 V4.7 w. PN (All versions < V4.7 HF27), SINAMICS G150 V4.7 w. PN (V4.7: All versions < V4.7 HF27), SINAMICS G130 V4.8 w. PN (All versions < V4.8 HF4), SINAMICS G150 V4.8 w. PN (All versions < V4.8 HF4), SINAMICS S110 w. PN (All versions < V4.4 SP3 HF5), SINAMICS S120 V4.7 w. PN (All versions < V4.7 HF27), and others. Siemens SIMATIC S7-300 F, etc. Siemens SIMATIC S7-300 F is a process controller. SIMATIC HMI Comfort Panels are touch screens

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201705-3221",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "sinumerik 828d",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinumerik 840d sl",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinumerik 828d",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "sinumerik 840d sl",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi mobile panels",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 343-1 adv",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic s7-1500 software controller",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.1"
      },
      {
        "model": "simatic teleservice adapter ie basic modem",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic tdc cp51m1",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.1.8"
      },
      {
        "model": "simatic cp 1543-1",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.0.15"
      },
      {
        "model": "simatic cp 1243-1 irc",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.1.82"
      },
      {
        "model": "sinamics dcm",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.4"
      },
      {
        "model": "sirius act 3su1",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.1.0"
      },
      {
        "model": "simatic rf680r",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.0"
      },
      {
        "model": "simatic cp 1543sp-1",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.0.15"
      },
      {
        "model": "sinamics g120\\ pn",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "simatic et 200al",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.0.2"
      },
      {
        "model": "simatic cp 1543sp-1",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.1"
      },
      {
        "model": "simatic cp 443-1 adv",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.2.17"
      },
      {
        "model": "scalance x414",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.10.2"
      },
      {
        "model": "sinumerik 828d",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "sinumerik 840d sl",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "softnet profinet io",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "14"
      },
      {
        "model": "simatic et 200pro",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "ek-ertec 200 pn io",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.2.1"
      },
      {
        "model": "simatic cp 1243-1 dnp3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x300",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.0"
      },
      {
        "model": "scalance s615",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.03"
      },
      {
        "model": "sinamics s110 pn",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.4"
      },
      {
        "model": "simatic s7-400",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "6.0.6"
      },
      {
        "model": "simatic et 200m",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "ups1600 profinet",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.2.0"
      },
      {
        "model": "sinamics dcp",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.2"
      },
      {
        "model": "simotion",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "sinamics dcm",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.4"
      },
      {
        "model": "dk standard ethernet controller",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.1"
      },
      {
        "model": "sinamics s120",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics g110m",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics g130",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "scalance xr500",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "6.1"
      },
      {
        "model": "simatic s7-200 smart",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.3"
      },
      {
        "model": "simatic et 200s",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic cp 1243-1",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.1.82"
      },
      {
        "model": "ek-ertec 200p pn io",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.4.0"
      },
      {
        "model": "simatic dk-16xx pn io",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.7"
      },
      {
        "model": "simatic tdc cpu555",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.1.1"
      },
      {
        "model": "simatic cp 1616",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.7"
      },
      {
        "model": "sinamics s120",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "simatic et 200sp",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.2.0"
      },
      {
        "model": "sinamics g150",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "scalance w700",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "6.1"
      },
      {
        "model": "simatic teleservice adapter ie advanced modem",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "sinamics g110m",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sirius motor starter m200d profinet",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "softnet profinet io",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "14"
      },
      {
        "model": "sinamics g130",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinumerik 828d",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinumerik 840d sl",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "scalance xm400",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "6.1"
      },
      {
        "model": "sirius soft starter 3rw44 pn",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic hmi multi panels",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic winac rtx",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2010"
      },
      {
        "model": "simocode pro v profinet",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.0.0"
      },
      {
        "model": "sinamics s110 pn",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.4"
      },
      {
        "model": "simatic hmi mobile panels",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic rf650r",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.0"
      },
      {
        "model": "ek-ertec 200 pn io",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.2.1"
      },
      {
        "model": "sinamics s150",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics g150",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "simatic cp 343-1 lean",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.1.3"
      },
      {
        "model": "ie\\/pb-link",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.0"
      },
      {
        "model": "scalance x200 irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.4.0"
      },
      {
        "model": "pn\\/pn coupler",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.0"
      },
      {
        "model": "simatic cp 1604",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.7"
      },
      {
        "model": "simatic et 200ecopn",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "ek-ertec 200p pn io",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.4.0"
      },
      {
        "model": "ie\\/as-i link pn io",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic rf685r",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.0"
      },
      {
        "model": "sinamics v90 pn",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.01"
      },
      {
        "model": "simatic cp 443-1 std",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.2.17"
      },
      {
        "model": "sinamics s150",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "simatic s7-300",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.3.17"
      },
      {
        "model": "simatic s7-1500",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.1"
      },
      {
        "model": "simatic cp 1243-1 iec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic cm 1542sp-1",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.0.15"
      },
      {
        "model": "scalance x200",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.2"
      },
      {
        "model": "simatic s7-1200",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.2.1"
      },
      {
        "model": "simatic cp 443-1 opc-ua",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "scalance m-800",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.03"
      },
      {
        "model": "simatic cp 343-1 std",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.1.3"
      },
      {
        "model": "simatic teleservice adapter standard modem",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simotion",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "sinamics dcp",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.2"
      },
      {
        "model": "scalance x408",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.0"
      },
      {
        "model": "sitop psu8600",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.2.0"
      },
      {
        "model": "dk standard ethernet controller",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.1"
      },
      {
        "model": "simatic cp 1542sp-1 irc",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.0.15"
      },
      {
        "model": "simatic et 200mp",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.0.1"
      },
      {
        "model": "simatic cm 1542-1",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.0"
      },
      {
        "model": "simatic winac rtx",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2010"
      },
      {
        "model": "dk standard ethernet controller",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "ek-ertec 200 pn io",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "ek-ertec 200p pn io",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "ie/as-i link pn io",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "ie/pb-link",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "pn/pn coupler",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance m-800",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance s615",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w700",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance x200 irt",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance x200",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance x300",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance x408",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance x414",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xm400",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xr500",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cm 1542-1",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 1243-1",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 1542sp-1 irc",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 1542sp-1",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 1543-1",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 1543sp-1",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 1604",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 1616",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 343-1 adv",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 343-1 lean",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 343-1 std",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 443-1 adv",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 443-1 opc-ua",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 443-1 std",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic dk-16xx pn io",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200al",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200ecopn",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200m",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200mp",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200pro",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200s",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200sp",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi multi panels",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic rf650r",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic rf680r",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic rf685r",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-1200",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-1500 software controller",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-1500",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-200 smart",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-300",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-400",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic teleservice adapter ie advanced",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic teleservice adapter ie basic",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic teleservice adapter standard modem",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic winac rtx 2010",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simocode pro v profinet",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simotion",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics dcm",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics dcp",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics g110m",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics g120 w. pn",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics g130",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics g150",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics s110 w. pn",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics s120",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics s150",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics v90 w. pn",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinumerik 828d",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinumerik 840d sl",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sirius act 3su1 interface module profinet",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sirius motor starter m200d profinet",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sirius soft starter 3rw44 pn",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sitop psu8600",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sitop ups1600 profinet",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "softnet profinet io",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "for pc-based windows systems firmware"
      },
      {
        "model": "simatic hmi multi panels",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics g150",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "simatic hmi mobile panels",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics s120",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics s110 w. pn",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.4,
        "vendor": "sinumerik 828d",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.4,
        "vendor": "sinumerik 840d sl",
        "version": "*"
      },
      {
        "model": "ups1600 profinet",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "softnet profinet io",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "sitop psu8600",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "sirius soft starter 3rw44 pn",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "sirius act 3su1",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "sinumerik 840d",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "sinumerik 828d",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "sinamics sm150",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics sm120",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics sl150",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7.5"
      },
      {
        "model": "sinamics sl150",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7.4"
      },
      {
        "model": "sinamics sl150",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics gm150",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics gl150",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics gh150",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simotion",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic winac rtx",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "20100"
      },
      {
        "model": "simatic teleservice adapter standard modem",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic s7-400",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic s7-300",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic s7-200 smart",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic s7-1500",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic rf685r",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic rf680r",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic rf650r",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic et",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "2000"
      },
      {
        "model": "simatic cp",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "443-10"
      },
      {
        "model": "simatic cp",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "343-10"
      },
      {
        "model": "simatic cp",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "16260"
      },
      {
        "model": "simatic cp",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "16160"
      },
      {
        "model": "simatic cp",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "16040"
      },
      {
        "model": "simatic cp",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1543-12.0.28"
      },
      {
        "model": "simatic cp",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1543-10"
      },
      {
        "model": "simatic cp 1542sp-1",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic cp irc",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1243-80"
      },
      {
        "model": "simatic cp lte eu/us",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1243-70"
      },
      {
        "model": "simatic cp",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1243-10"
      },
      {
        "model": "simatic cp gprs",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1242-7v20"
      },
      {
        "model": "scalance xr500",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "scalance xm400",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "x4140"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "x4084.0"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "x4083.0"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "x3000"
      },
      {
        "model": "scalance irt",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "x2000"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "x2000"
      },
      {
        "model": "scalance w700 series",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.4"
      },
      {
        "model": "scalance w700 series",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.5.4"
      },
      {
        "model": "scalance s615",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "scalance m-800",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.02"
      },
      {
        "model": "scalance m-800",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "ie/as-i link pn io",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "extension unit profinet",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "22?0"
      },
      {
        "model": "extension unit profinet",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "19?0"
      },
      {
        "model": "extension unit profinet",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15?0"
      },
      {
        "model": "extension unit profinet",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "12?0"
      },
      {
        "model": "e/pb-link",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "sinumerik 840d sl",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinumerik 828d",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics sm120 sp2",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "sinamics sl150 sp2",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "sinamics gm150 sp2",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "sinamics gl150 sp2",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "sinamics gh150 sp2",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "simatic rf685r",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "3.0"
      },
      {
        "model": "simatic rf680r",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "3.0"
      },
      {
        "model": "simatic cp",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "16162.7"
      },
      {
        "model": "simatic cp 1604d",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "2.7"
      },
      {
        "model": "simatic cp irc",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1243-82.1.82"
      },
      {
        "model": "simatic cp lte eu/us",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1243-72.1.82"
      },
      {
        "model": "simatic cp gprs",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1242-7v22.1.82"
      },
      {
        "model": "simatic rf650r",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "3.0"
      },
      {
        "model": "simatic cp",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "443-13.2.17"
      },
      {
        "model": "simatic cp",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15431.2.1"
      },
      {
        "model": "simatic cm1542",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1.2"
      },
      {
        "model": "scalance w700",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "6.1"
      },
      {
        "model": "extension unit profinet",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "22?1.1.1"
      },
      {
        "model": "extension unit profinet",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "19?1.1.1"
      },
      {
        "model": "extension unit profinet",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15?1.1.1"
      },
      {
        "model": "extension unit profinet",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "12?1.1.1"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp 343 1 std",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp 1542sp 1 irc",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp 1543sp 1",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp 1543 1",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic rf650r",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic rf680r",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic rf685r",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp 1616",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp 1604",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic dk 16xx pn io",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "scalance x200",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp 343 1 lean",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "scalance x200 irt",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "scalance x300",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "scalance x408",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "scalance x414",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "scalance xm400",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "scalance xr500",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "scalance w700",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "scalance m 800",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "scalance s615",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "softnet profinet io",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp 343 1 adv",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "ie pb link",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "ie as i link pn io",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic teleservice adapter standard modem",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic teleservice adapter ie basic modem",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic teleservice adapter ie advanced modem",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sitop psu8600",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "ups1600 profinet",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200al",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200ecopn",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200m",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp 443 1 std",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200mp",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200pro",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200s",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200sp",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "pn pn coupler",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dk standard ethernet controller",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "ek ertec 200p pn io",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "ek ertec 200 pn io",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 200 smart",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 300",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp 443 1 adv",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 400",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 1200",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 1500",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 1500 controller",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic winac rtx 2010",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sirius act 3su1",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sirius soft starter 3rw44 pn",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sirius motor starter m200d profinet",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simocode pro v profinet",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics dcm",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp 443 1 opc ua",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics dcp",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics g110m",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics g120 c p d w pn",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics g130",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics g150",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics s110 w pn",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics s120",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics s150",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics v90 w pn",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simotion",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp 1243 1",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic hmi comfort panels",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic hmi multi panels",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic hmi mobile panels",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cm 1542 1",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp 1542sp 1",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "33467505-7492-4ae1-b978-12f61201709a"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-06153"
      },
      {
        "db": "BID",
        "id": "98369"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-004135"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-2681"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201705-639"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_343-1_std_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "3.1.3",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_343-1_std:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_343-1_lean_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "3.1.3",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_343-1_lean:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_343-1_adv_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_343-1_adv:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_443-1_std_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "3.2.17",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_443-1_std:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_443-1_adv_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "3.2.17",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_443-1_adv:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_443-1_opc-ua_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_443-1_opc-ua:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1243-1_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "2.1.82",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1243-1:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_cm_1542-1_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "2.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_cm_1542-1:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1543sp-1_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "1.0.15",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1542sp-1:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1542sp-1_irc_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "1.0.15",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1542sp-1_irc:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1543sp-1_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "2.1",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1543sp-1:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1543-1_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "1.0.15",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1543-1:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_rf650r_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "3.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_rf650r:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_rf680r_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "3.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_rf680r:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_rf685r_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "3.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_rf685r:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1616_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "2.7",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1616:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1604_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "2.7",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1604:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_dk-16xx_pn_io_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "2.7",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_dk-16xx_pn_io:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x200_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.2",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x200:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x200_irt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.4.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x200_irt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x300_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x300:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x408_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x408:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x414_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "3.10.2",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x414:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xm400_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "6.1",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xm400:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr500_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "6.1",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr500:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_w700_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "6.1",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_w700:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_m-800_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.03",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_m-800:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_s615_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.03",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:softnet_profinet_io_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "14",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:softnet_profinet_io_firmware:14:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:softnet_profinet_io:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:ie\\/pb-link_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "3.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:ie\\/pb-link:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:ie\\/as-i_link_pn_io_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:ie\\/as-i_link_pn_io:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_teleservice_adapter_standard_modem_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_teleservice_adapter_standard_modem:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_teleservice_adapter_ie_basic_modem_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_teleservice_adapter_ie_basic_modem:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_teleservice_adapter_ie_advanced_modem_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_teleservice_adapter_ie_advanced_modem:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sitop_psu8600_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "1.2.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sitop_psu8600:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:ups1600_profinet_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "2.2.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:ups1600_profinet:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200al_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "1.0.2",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200al:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200ecopn_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200ecopn:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200m_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200m:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200mp_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.0.1",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200mp:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200pro_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200pro:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200s_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200s:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200sp_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.2.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200sp:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:pn\\/pn_coupler_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:pn\\/pn_coupler:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.1",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:4.1.1:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:dk_standard_ethernet_controller:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:ek-ertec_200p_pn_io_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.4.0",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:ek-ertec_200p_pn_io_firmware:4.4.0:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:ek-ertec_200p_pn_io:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:ek-ertec_200_pn_io_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.2.1",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:ek-ertec_200_pn_io_firmware:4.2.1:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:ek-ertec_200_pn_io:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-200_smart_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "2.3",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-200_smart:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "3.3.17",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-400_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "6.0.6",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-400:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1200_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.2.1",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1200:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1500_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "2.1",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1500:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_winac_rtx_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "2010",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_winac_rtx_firmware:2010:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_winac_rtx:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sirius_act_3su1_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "1.1.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sirius_act_3su1:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sirius_soft_starter_3rw44_pn_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sirius_soft_starter_3rw44_pn:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sirius_motor_starter_m200d_profinet_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sirius_motor_starter_m200d_profinet:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simocode_pro_v_profinet_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "2.0.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simocode_pro_v_profinet:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_dcm_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "1.4",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_dcm_firmware:1.4:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_dcm:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_dcp_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "1.2",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_dcp_firmware:1.2:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_dcp:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g110m_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.7",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g110m_firmware:4.7:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_g110m:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g120\\(c\\/p\\/d\\)_pn_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.7",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_g120\\(c\\/p\\/d\\)_pn:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g130_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.7",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g130_firmware:4.7:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_g130:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g150_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.7",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g150_firmware:4.7:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_g150:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_s110_pn_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.4",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_s110_pn_firmware:4.4:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_s110_pn:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_s120_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.7",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_s120_firmware:4.7:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_s150_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.7",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_s150_firmware:4.7:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_s150:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_v90_pn_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "1.01",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_v90_pn:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simotion_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.5",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simotion_firmware:4.5:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simotion:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinumerik_828d_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.5",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinumerik_828d_firmware:4.5:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinumerik_828d:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinumerik_840d_sl_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.5",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinumerik_840d_sl_firmware:4.5:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinumerik_840d_sl:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "15.1",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_multi_panels:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "15.1",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_multi_panels:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_mobile_panels:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "15.1",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_mobile_panels:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1243-1_irc_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "2.1.82",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1243-1_irc:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1243-1_iec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1243-1_iec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1243-1_dnp3_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1243-1_dnp3:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_cm_1542sp-1_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "1.0.15",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_cm_1542sp-1:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_s7-1500_software_controller:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "2.1",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinumerik_828d_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.7",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinumerik_828d_firmware:4.7:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinumerik_828d:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinumerik_840d_sl_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.7",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinumerik_840d_sl_firmware:4.7:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinumerik_840d_sl:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_tdc_cpu555_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "1.1.1",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_tdc_cpu555:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_tdc_cp51m1_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "1.1.8",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_tdc_cp51m1:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2017-2681"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Duan JinTong, Ma ShaoShuai, and Cheng Lei from NSFOCUS Security Team.",
    "sources": [
      {
        "db": "BID",
        "id": "98369"
      }
    ],
    "trust": 0.3
  },
  "cve": "CVE-2017-2681",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 6.1,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 6.5,
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "MEDIUM",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Adjacent Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Complete",
            "baseScore": 6.1,
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2017-2681",
            "impactScore": null,
            "integrityImpact": "None",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "Medium",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 6.1,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 6.5,
            "id": "CNVD-2017-06153",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 6.1,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 6.5,
            "id": "33467505-7492-4ae1-b978-12f61201709a",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.2,
            "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 6.1,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 6.5,
            "id": "VHN-110884",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:A/AC:L/AU:N/C:N/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 2.8,
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Adjacent Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 6.5,
            "baseSeverity": "Medium",
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2017-2681",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2017-2681",
            "trust": 1.8,
            "value": "MEDIUM"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2017-06153",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201705-639",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "IVD",
            "id": "33467505-7492-4ae1-b978-12f61201709a",
            "trust": 0.2,
            "value": "MEDIUM"
          },
          {
            "author": "VULHUB",
            "id": "VHN-110884",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "33467505-7492-4ae1-b978-12f61201709a"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-06153"
      },
      {
        "db": "VULHUB",
        "id": "VHN-110884"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-004135"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-2681"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201705-639"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected. This vulnerability affects only SIMATIC HMI Multi Panels and HMI Mobile Panels, and S7-300/S7-400 devices. SIMATIC HMI is an industrial device from Siemens AG, Germany. The SIMATIC HMI panels are used for operator control and monitoring of machines and equipment. Multiple Siemens Products is prone to multiple denial-of-service vulnerabilities. \nAttackers can exploit these issues to cause a denial-of-service condition. Manual restart of the server is required to resume normal operation. A vulnerability has been identified in SIMATIC CP 343-1 Std (All versions), SIMATIC CP 343-1 Lean (All versions), SIMATIC CP 343-1 Adv (All versions), SIMATIC CP 443-1 Std (All versions \u003c V3.2.17), SIMATIC CP 443-1 Adv (All versions \u003c V3.2.17), SIMATIC CP 443-1 OPC-UA (All versions), SIMATIC CP 1243-1 (All versions \u003c V2.1.82), SIMATIC CP 1243-1 IRC (All versions \u003c V2.1.82), SIMATIC CP 1243-1 IEC (All versions), SIMATIC CP 1243-1 DNP3 (All versions), SIMATIC CM 1542-1 (All versions \u003c V2.0), SIMATIC CM 1542SP-1 (All versions \u003c V1.0.15), SIMATIC CP 1542SP-1 IRC (All versions \u003c V1.0.15), SIMATIC CP 1543SP-1 (All versions \u003c V1.0.15), SIMATIC CP 1543-1 (All versions \u003c V2.1), SIMATIC RF650R (All versions \u003c V3.0), SIMATIC RF680R (All versions \u003c V3.0), SIMATIC RF685R (All versions \u003c V3.0), SIMATIC CP 1616 (All versions \u003c V2.7), SIMATIC CP 1604 (All versions \u003c V2.7), SIMATIC DK-16xx PN IO (All versions \u003c V2.7), SCALANCE X-200 (All versions \u003c V5.2.2), SCALANCE X-200 IRT (All versions), SCALANCE X-300/X408 (All versions \u003c V4.1.0), SCALANCE X414 (All versions \u003c V3.10.2), SCALANCE XM400 (All versions \u003c V6.1), SCALANCE XR500 (All versions \u003c V6.1), SCALANCE W700 (All versions \u003c V6.1), SCALANCE M-800, S615 (All versions \u003c V4.03), Softnet PROFINET IO for PC-based Windows systems (All versions \u003c V14 SP1), IE/PB-Link (All versions \u003c V3.0), IE/AS-i Link PN IO (All versions), SIMATIC Teleservice Adapter Standard Modem, IE Basic, IE Advanced (All versions), SITOP PSU8600 PROFINET (All versions \u003c V1.2.0), SITOP UPS1600 PROFINET (All versions \u003c V2.2.0), SIMATIC ET 200AL (All versions \u003c V1.0.2), SIMATIC ET 200ecoPN (All versions), SIMATIC ET 200M (All versions), SIMATIC ET 200MP IM155-5 PN BA (All versions \u003c V4.0.1), SIMATIC ET 200MP IM155-5 PN ST (All versions \u003c V4.1), SIMATIC ET 200MP (except IM155-5 PN BA and IM155-5 PN ST) (All versions), SIMATIC ET 200pro (All versions), SIMATIC ET 200S (All versions), SIMATIC ET 200SP IM155-6 PN ST (All versions \u003c V4.1.0), SIMATIC ET 200SP (except IM155-6 PN ST) (All versions), SIMATIC PN/PN Coupler (All versions \u003c V4.0), Development/Evaluation Kit DK Standard Ethernet Controller (All versions \u003c V4.1.1 Patch04), Development/Evaluation Kit EK-ERTEC 200P (All versions \u003c V4.4.0 Patch01), Development/Evaluation Kit EK-ERTEC 200 (All versions \u003c V4.2.1 Patch03), SIMATIC S7-200 SMART (All versions \u003c V2.3), SIMATIC S7-300 incl. F and T (All versions \u003c V3.X.14), SIMATIC S7-400 PN/DP V6 Incl. F (All versions \u003c V6.0.6), SIMATIC S7-400-H V6 (All versions \u003c V6.0.7), SIMATIC S7-400 PN/DP V7 Incl. F (All versions \u003c V7.0.2), SIMATIC S7-410 (All versions \u003c V8.2), SIMATIC S7-1200 incl. F (All versions \u003c V4.2.1), SIMATIC S7-1500 incl. F, T, and TF (All versions \u003c V2.1), SIMATIC S7-1500 Software Controller incl. F (All versions \u003c V2.1), SIMATIC WinAC RTX 2010 incl. F (All versions), SIRIUS ACT 3SU1 interface module PROFINET (All versions), SIRIUS Soft Starter 3RW44 PN (All versions), SIRIUS Motor Starter M200D PROFINET (All versions), SIMOCODE pro V PROFINET (All versions \u003c V2.0.0), SINAMICS DCM w. PN (All versions \u003c V1.4 SP1 HF5), SINAMICS DCP w. PN (All versions \u003c V1.2 HF 1), SINAMICS G110M w. PN (All versions \u003c V4.7 SP6 HF3), SINAMICS G120(C/P/D) w. PN (All versions \u003c V4.7 SP6 HF3), SINAMICS G130 V4.7 w. PN (All versions \u003c V4.7 HF27), SINAMICS G150 V4.7 w. PN (V4.7: All versions \u003c V4.7 HF27), SINAMICS G130 V4.8 w. PN (All versions \u003c V4.8 HF4), SINAMICS G150 V4.8 w. PN (All versions \u003c V4.8 HF4), SINAMICS S110 w. PN (All versions \u003c V4.4 SP3 HF5), SINAMICS S120 V4.7 w. PN (All versions \u003c V4.7 HF27), and others. Siemens SIMATIC S7-300 F, etc. Siemens SIMATIC S7-300 F is a process controller. SIMATIC HMI Comfort Panels are touch screens",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2017-2681"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-004135"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-06153"
      },
      {
        "db": "BID",
        "id": "98369"
      },
      {
        "db": "IVD",
        "id": "33467505-7492-4ae1-b978-12f61201709a"
      },
      {
        "db": "VULHUB",
        "id": "VHN-110884"
      }
    ],
    "trust": 2.7
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2017-2681",
        "trust": 3.6
      },
      {
        "db": "SIEMENS",
        "id": "SSA-293562",
        "trust": 2.6
      },
      {
        "db": "BID",
        "id": "98369",
        "trust": 2.0
      },
      {
        "db": "SECTRACK",
        "id": "1038463",
        "trust": 1.7
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-17-129-02",
        "trust": 1.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-06153",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201705-639",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-004135",
        "trust": 0.8
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-18-023-02",
        "trust": 0.3
      },
      {
        "db": "SIEMENS",
        "id": "SSA-284673",
        "trust": 0.3
      },
      {
        "db": "IVD",
        "id": "33467505-7492-4AE1-B978-12F61201709A",
        "trust": 0.2
      },
      {
        "db": "VULHUB",
        "id": "VHN-110884",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "33467505-7492-4ae1-b978-12f61201709a"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-06153"
      },
      {
        "db": "VULHUB",
        "id": "VHN-110884"
      },
      {
        "db": "BID",
        "id": "98369"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-004135"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-2681"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201705-639"
      }
    ]
  },
  "id": "VAR-201705-3221",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "33467505-7492-4ae1-b978-12f61201709a"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-06153"
      },
      {
        "db": "VULHUB",
        "id": "VHN-110884"
      }
    ],
    "trust": 1.4971765550000002
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "33467505-7492-4ae1-b978-12f61201709a"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-06153"
      }
    ]
  },
  "last_update_date": "2023-12-18T12:51:14.181000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-293562",
        "trust": 0.8,
        "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf"
      },
      {
        "title": "Patch for Siemens SIMATIC HMI Denial of Service Vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchinfo/show/93365"
      },
      {
        "title": "Multiple Siemens Product security vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=70109"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-06153"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-004135"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201705-639"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-400",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-20",
        "trust": 0.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-110884"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-004135"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-2681"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.6,
        "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf"
      },
      {
        "trust": 1.7,
        "url": "http://www.securityfocus.com/bid/98369"
      },
      {
        "trust": 1.7,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf"
      },
      {
        "trust": 1.7,
        "url": "http://www.securitytracker.com/id/1038463"
      },
      {
        "trust": 1.1,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-17-129-02"
      },
      {
        "trust": 0.8,
        "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-2681"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2017-2681"
      },
      {
        "trust": 0.6,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-17-129-02"
      },
      {
        "trust": 0.3,
        "url": "http://subscriber.communications.siemens.com/"
      },
      {
        "trust": 0.3,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-18-023-02"
      },
      {
        "trust": 0.3,
        "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdf"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-06153"
      },
      {
        "db": "VULHUB",
        "id": "VHN-110884"
      },
      {
        "db": "BID",
        "id": "98369"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-004135"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-2681"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201705-639"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "33467505-7492-4ae1-b978-12f61201709a"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-06153"
      },
      {
        "db": "VULHUB",
        "id": "VHN-110884"
      },
      {
        "db": "BID",
        "id": "98369"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-004135"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-2681"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201705-639"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2017-05-09T00:00:00",
        "db": "IVD",
        "id": "33467505-7492-4ae1-b978-12f61201709a"
      },
      {
        "date": "2017-05-09T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2017-06153"
      },
      {
        "date": "2017-05-11T00:00:00",
        "db": "VULHUB",
        "id": "VHN-110884"
      },
      {
        "date": "2017-05-08T00:00:00",
        "db": "BID",
        "id": "98369"
      },
      {
        "date": "2017-06-16T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2017-004135"
      },
      {
        "date": "2017-05-11T10:29:00.180000",
        "db": "NVD",
        "id": "CVE-2017-2681"
      },
      {
        "date": "2017-05-12T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201705-639"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2017-05-09T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2017-06153"
      },
      {
        "date": "2020-09-29T00:00:00",
        "db": "VULHUB",
        "id": "VHN-110884"
      },
      {
        "date": "2018-05-09T14:00:00",
        "db": "BID",
        "id": "98369"
      },
      {
        "date": "2017-09-11T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2017-004135"
      },
      {
        "date": "2022-04-12T18:29:19.557000",
        "db": "NVD",
        "id": "CVE-2017-2681"
      },
      {
        "date": "2022-03-10T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201705-639"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote or local",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201705-639"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Siemens SIMATIC HMI Denial of service vulnerability",
    "sources": [
      {
        "db": "IVD",
        "id": "33467505-7492-4ae1-b978-12f61201709a"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-06153"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "resource management error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201705-639"
      }
    ],
    "trust": 0.6
  }
}

var-201705-3220
Vulnerability from variot

Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected. SIMATIC CP, SIMATIC RF600, SCALANCE W700, etc. are all industrial automation products from Siemens AG. A denial of service vulnerability exists in several industrial devices from Siemens. Multiple Siemens Products is prone to multiple denial-of-service vulnerabilities. Attackers can exploit these issues to cause a denial-of-service condition. Manual restart of the server is required to resume normal operation. SIEMENS SIMATIC CP 343-1 Std, CP 343-1 Lean (All versions), SIMATIC CP 343-1 Adv (All versions), SIMATIC CP 443-1 Std, CP 443-1 Adv (All versions before V3.2.17), SIMATIC CP 443-1 OPC-UA (All versions), SIMATIC CP 1243-1 (All versions before V2.1.82), SIMATIC CP 1243-1 IRC (All versions before V2.1.82), SIMATIC CP 1243-1 IEC (All versions), SIMATIC CP 1243-1 DNP3 (All versions), SIMATIC CM 1542-1 (All versions before V2.0), SIMATIC CP 1542SP-1, CP 1542SP-1 IRC, and CP 1543SP-1 (All versions before to V1.0.15), SIMATIC CP 1543-1 (All versions before V2.1), SIMATIC RF650R, RF680R, RF685R (All versions before V3.0), SIMATIC CP 1616, CP 1604, DK-16xx PN IO (All versions before V2.7), SCALANCE X-200 (All versions before V5.2.2), SCALANCE X200 IRT (All versions before V5.4.0), SCALANCE X-300/X408 (All versions before V4.1.0), SCALANCE X414 (All versions before V3.10.2), SCALANCE XM400, XR500 (All versions before V6.1), SCALANCE W700 (All versions before V6.1), SCALANCE M-800, S615 (All versions before V04.03), Softnet PROFINET IO for PC-based Windows systems (All versions before V14 SP1), IE/PB-Link (All versions before V3.0), IE/AS-i Link PN IO (All versions), SIMATIC Teleservice Adapter Standard Modem, IE Basic, IE Advanced (All versions), SITOP PSU8600 PROFINET (All versions before V1.2.0), SITOP UPS1600 PROFINET (All versions before V2.2.0), SIMATIC ET 200AL (All versions before V1.0.2), SIMATIC ET 200ecoPN (All versions), SIMATIC ET 200M (All versions), SIMATIC ET 200MP (All versions before V4.0.1), SIMATIC ET 200pro (All versions), SIMATIC ET 200S (All versions), SIMATIC ET 200SP (All versions before V4.1.0), SIMATIC PN/PN Coupler (All versions before V4.0), DK Standard Ethernet Controller (All versions before V4.1.1 Patch04), EK-ERTEC 200P PN IO (All versions before V4.4.0 Patch01), EK-ERTEC 200 PN IO (All versions before V4.2.1 Patch03), SIMATIC S7-200 SMART (All versions before V2.3), SIMATIC S7-300 incl. F and T (All versions before V3.X.14), SIMATIC S7-400 PN/DP V6 Incl. F (All versions before V6.0.6), SIMATIC S7-400-H V6 (All versions before V6.0.7), SIMATIC S7-400 PN/DP V7 incl. F (All versions), SIMATIC S7-CPU 410 (All versions before V8.2), SIMATIC S7-1200 incl. F (All versions before V4.2.1), SIMATIC S7-1500 incl. F, T, and TF (All versions before V2.1), SIMATIC S7-1500 Software Controller incl. F (All versions before V2.1), SIMATIC WinAC RTX 2010 incl. F (All versions), SIRIUS ACT 3SU1 interface module PROFINET (All versions), SIRIUS Soft starter 3RW44 PN (All versions), SIRIUS Motor starter M200D PROFINET (All versions), SIMOCODE pro V PROFINET (All versions), SINAMICS DCM (All versions before V1.4 SP1 HF5), SINAMICS DCP (All versions), SINAMICS G110M / G120(C/P/D) w. PN (All versions before V4.7 SP6 HF3), SINAMICS G130 and G150 (All versions before V4.7 HF27 and V4.8 before HF4), SINAMICS S110 w. PN (All versions before V4.4 SP1 HF5), SINAMICS S120 (All versions before V4.7 HF27 and V4.8 before HF4), SINAMICS S150 (All versions before V4.7 HF27 and V4.8 before HF4), SINAMICS V90 w. PN (All versions before V1.1), SIMOTION (All versions before V4.5 HF1), SINUMERIK 828D (All versions before V4.5 SP6 HF2 and V4.7 before SP6 HF8), SINUMERIK 840D sl (All versions before V4.5 SP6 HF8 and V4.7 before SP4 HF1), SIMATIC HMI Comfort Panels, HMI Multi Panels, HMI Mobile Panels (All versions) could be affected by a Denial-of-Service condition induced by a specially crafted PROFINET DCP broadcast (Layer 2 - Ethernet) packet. Siemens SIMATIC S7-200 Smart, etc. Siemens SIMATIC S7-200 Smart is a programmable logic controller (PLC) used in small and medium-sized automation systems. Siemens SIMATIC CP 343-1 Advanced is an Ethernet communication module used to support PROFINET (a new generation of automation bus standard based on industrial Ethernet technology). SIRIUS Motor starter M200D PROFINET is a motor starter. The following products and versions are affected: Siemens Extension Unit 12\" PROFINET prior to V01.01.01; Extension Unit 15\" PROFINET prior to V01.01.01; Extension Unit 19\" PROFINET prior to V01.01.01; Extension Unit 22\" PROFINET SIMATIC CP 1242-7 GPRS V2 prior to V2.1.82; SIMATIC CP 1243-7 LTE/US prior to V2.1.82; SIMATIC CP 1243-8 prior to V2.1.82; SIMATIC CP 1626 V1.1 previous version

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201705-3220",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "simatic dk-16xx pn io",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic rf685r",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic rf650r",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic rf680r",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 1543sp-1",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 1542sp-1 irc",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 1542sp-1",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xr500",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance s615",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance m-800",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xm400",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance w700",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics gm150",
        "scope": "eq",
        "trust": 1.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics gh150",
        "scope": "eq",
        "trust": 1.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "simatic dk-1604 pn io",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.7"
      },
      {
        "model": "simatic cp 343-1 adv",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic tdc cp51m1",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.1.8"
      },
      {
        "model": "simatic cp 1243-1 irc",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.1.82"
      },
      {
        "model": "sinamics dcm",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.4"
      },
      {
        "model": "sinamics g120\\ w. pn",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "simatic cp 1543-1",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.1"
      },
      {
        "model": "sirius act 3su1",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.1.0"
      },
      {
        "model": "simatic rf680r",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.0"
      },
      {
        "model": "simatic cp 1543sp-1",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.0.15"
      },
      {
        "model": "simatic et 200al",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.0.2"
      },
      {
        "model": "simatic cp 443-1 adv",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.2.17"
      },
      {
        "model": "scalance x414",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.10.2"
      },
      {
        "model": "sinumerik 828d",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "sinumerik 840d sl",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "sinamics gl150",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "softnet profinet io",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "14"
      },
      {
        "model": "simatic et 200pro",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "ek-ertec 200 pn io",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.2.1"
      },
      {
        "model": "simatic cp 1243-1 dnp3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x300",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.0"
      },
      {
        "model": "scalance s615",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.03"
      },
      {
        "model": "sinamics s110 pn",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.4"
      },
      {
        "model": "simatic s7-400",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "6.0.6"
      },
      {
        "model": "simatic et 200m",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "ups1600 profinet",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.2.0"
      },
      {
        "model": "sinamics dcp",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.2"
      },
      {
        "model": "simotion",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "sinamics gm150",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics dcm",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.4"
      },
      {
        "model": "dk standard ethernet controller",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.1"
      },
      {
        "model": "sinamics s120",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics sl150",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "sinamics g110m",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "simatic cp 1242-7 gprs",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.1.82"
      },
      {
        "model": "sinamics g130",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "simatic cp 1542sp-1",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.0.15"
      },
      {
        "model": "extension unit 22 profinet",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "01.01.01"
      },
      {
        "model": "scalance xr500",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "6.1"
      },
      {
        "model": "simatic s7-200 smart",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.3"
      },
      {
        "model": "simatic et 200s",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic cp 1243-1",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.1.82"
      },
      {
        "model": "sinamics sm120",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "ek-ertec 200p pn io",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.4.0"
      },
      {
        "model": "simatic tdc cpu555",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.1.1"
      },
      {
        "model": "sinamics s110 pn",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.4"
      },
      {
        "model": "simatic cp 1616",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.7"
      },
      {
        "model": "sinamics s120",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics g150",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "scalance w700",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "6.1"
      },
      {
        "model": "sinamics gl150",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "sinamics g110m",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sirius motor starter m200d profinet",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "softnet profinet io",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "14"
      },
      {
        "model": "sinamics g130",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "simatic cp 1243-7 lte\\/us",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.1.82"
      },
      {
        "model": "simatic et 200sp",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.0"
      },
      {
        "model": "scalance xm400",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "6.1"
      },
      {
        "model": "sirius soft starter 3rw44 pn",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic hmi multi panels",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic winac rtx",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2010"
      },
      {
        "model": "simocode pro v profinet",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.0.0"
      },
      {
        "model": "sinamics gh150",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "simatic hmi mobile panels",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic rf650r",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.0"
      },
      {
        "model": "simatic teleservice adapter ie basic",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "ek-ertec 200 pn io",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.2.1"
      },
      {
        "model": "sinamics s150",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "simatic cp 1243-8",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.1.82"
      },
      {
        "model": "sinamics g150",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics sl150",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "sinamics sm120",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "simatic cp 1626",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.1"
      },
      {
        "model": "simatic cp 343-1 lean",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.1.3"
      },
      {
        "model": "ie\\/pb-link",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.0"
      },
      {
        "model": "scalance x200 irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.4.0"
      },
      {
        "model": "pn\\/pn coupler",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.0"
      },
      {
        "model": "simatic cp 1604",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.7"
      },
      {
        "model": "simatic et 200ecopn",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "ek-ertec 200p pn io",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.4.0"
      },
      {
        "model": "ie\\/as-i link pn io",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic rf685r",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.0"
      },
      {
        "model": "sinumerik 828d",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "sinamics g120\\ w. pn",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics v90 pn",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.01"
      },
      {
        "model": "extension unit 19 profinet",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "01.01.01"
      },
      {
        "model": "simatic cp 443-1 std",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.2.17"
      },
      {
        "model": "simatic teleservice adapter ie standard",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "sinamics s150",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "simatic s7-300",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "extension unit 15 profinet",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "01.01.01"
      },
      {
        "model": "simatic s7-1500",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.1"
      },
      {
        "model": "simatic cp 1243-1 iec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic dk-1616 pn io",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.7"
      },
      {
        "model": "scalance x200",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.2"
      },
      {
        "model": "simatic s7-1200",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.2.1"
      },
      {
        "model": "simatic cp 443-1 opc-ua",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "sinumerik 840d sl",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "scalance m-800",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.03"
      },
      {
        "model": "simatic cp 343-1 std",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.1.3"
      },
      {
        "model": "simotion",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "sinamics dcp",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.2"
      },
      {
        "model": "scalance x408",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.0"
      },
      {
        "model": "extension unit 12 profinet",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "01.01.01"
      },
      {
        "model": "simatic s7-1500 software controller",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.1"
      },
      {
        "model": "sitop psu8600",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.2.0"
      },
      {
        "model": "dk standard ethernet controller",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.1"
      },
      {
        "model": "simatic cp 1542sp-1 irc",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.0.15"
      },
      {
        "model": "simatic et 200mp",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.0.1"
      },
      {
        "model": "simatic teleservice adapter ie advanced",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic cm 1542-1",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.0"
      },
      {
        "model": "simatic winac rtx",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2010"
      },
      {
        "model": "dk standard ethernet controller",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "ek-ertec 200 pn io",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "ek-ertec 200p pn io",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "ie/as-i link pn io",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "ie/pb-link",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "pn/pn coupler",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance x200 irt",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance x200",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance x300",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance x408",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance x414",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cm 1542-1",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 1243-1",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 1543-1",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 1604",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 1616",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 343-1 adv",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 343-1 lean",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 343-1 std",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 443-1 adv",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 443-1 opc-ua",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 443-1 std",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200al",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200ecopn",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200m",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200mp",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200pro",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200s",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200sp",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi mobile panels",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi multi panels",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-1200",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-1500 software controller",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-1500",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-200 smart",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-300",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-400",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic teleservice adapter ie advanced",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic teleservice adapter ie basic",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic teleservice adapter standard modem",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic winac rtx 2010",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simocode pro v profinet",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simotion",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics dcm",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics dcp",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics g110m",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics g120 w. pn",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics g130",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics g150",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics s110 w. pn",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics s120",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics s150",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics v90 w. pn",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinumerik 828d",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinumerik 840d sl",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sirius act 3su1 interface module profinet",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sirius motor starter m200d profinet",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sirius soft starter 3rw44 pn",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sitop psu8600",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sitop ups1600 profinet",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "softnet profinet io",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "for pc-based windows systems firmware"
      },
      {
        "model": "simatic cp",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "1616"
      },
      {
        "model": "simatic cp",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "1604"
      },
      {
        "model": "simatic cp",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "1543-1"
      },
      {
        "model": "simatic cm",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "1542-1"
      },
      {
        "model": "simatic cp",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "1243-1"
      },
      {
        "model": "simatic cp opc-ua",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "443-1"
      },
      {
        "model": "simatic cp adv",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "443-1"
      },
      {
        "model": "simatic cp std",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "443-1"
      },
      {
        "model": "simatic cp std",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "343-1"
      },
      {
        "model": "simatic cp lean",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "343-1"
      },
      {
        "model": "simatic cp adv",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "343-1"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x408"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x414"
      },
      {
        "model": "scalance irt",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x200"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x200"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x300"
      },
      {
        "model": "simatic rf650r",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 443-1 opc-ua",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cm 1542-1",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 1542sp-1 irc",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 443-1 adv",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 343-1 std",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 1543-1",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 1543sp-1",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 1542sp-1",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic rf680r",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.4,
        "vendor": "sinumerik 828d",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.4,
        "vendor": "sinumerik 840d sl",
        "version": "*"
      },
      {
        "model": "ups1600 profinet",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "softnet profinet io",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "sitop psu8600",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "sirius soft starter 3rw44 pn",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "sirius act 3su1",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "sinumerik 840d",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "sinumerik 828d",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "sinamics sm150",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics sm120",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics sl150",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7.5"
      },
      {
        "model": "sinamics sl150",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7.4"
      },
      {
        "model": "sinamics sl150",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics gl150",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simotion",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic winac rtx",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "20100"
      },
      {
        "model": "simatic teleservice adapter standard modem",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic s7-400",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic s7-300",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic s7-200 smart",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic s7-1500",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic rf685r",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic rf680r",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic rf650r",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic et",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "2000"
      },
      {
        "model": "simatic cp",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "443-10"
      },
      {
        "model": "simatic cp",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "343-10"
      },
      {
        "model": "simatic cp",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "16260"
      },
      {
        "model": "simatic cp",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "16160"
      },
      {
        "model": "simatic cp",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "16040"
      },
      {
        "model": "simatic cp",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1543-12.0.28"
      },
      {
        "model": "simatic cp",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1543-10"
      },
      {
        "model": "simatic cp 1542sp-1",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic cp irc",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1243-80"
      },
      {
        "model": "simatic cp lte eu/us",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1243-70"
      },
      {
        "model": "simatic cp",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1243-10"
      },
      {
        "model": "simatic cp gprs",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1242-7v20"
      },
      {
        "model": "scalance xr500",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "scalance xm400",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "x4140"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "x4084.0"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "x4083.0"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "x3000"
      },
      {
        "model": "scalance irt",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "x2000"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "x2000"
      },
      {
        "model": "scalance w700 series",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.4"
      },
      {
        "model": "scalance w700 series",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.5.4"
      },
      {
        "model": "scalance s615",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "scalance m-800",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.02"
      },
      {
        "model": "scalance m-800",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "ie/as-i link pn io",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "extension unit profinet",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "22?0"
      },
      {
        "model": "extension unit profinet",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "19?0"
      },
      {
        "model": "extension unit profinet",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15?0"
      },
      {
        "model": "extension unit profinet",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "12?0"
      },
      {
        "model": "e/pb-link",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "sinumerik 840d sl",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinumerik 828d",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics sm120 sp2",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "sinamics sl150 sp2",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "sinamics gm150 sp2",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "sinamics gl150 sp2",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "sinamics gh150 sp2",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "simatic rf685r",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "3.0"
      },
      {
        "model": "simatic rf680r",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "3.0"
      },
      {
        "model": "simatic cp",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "16162.7"
      },
      {
        "model": "simatic cp 1604d",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "2.7"
      },
      {
        "model": "simatic cp irc",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1243-82.1.82"
      },
      {
        "model": "simatic cp lte eu/us",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1243-72.1.82"
      },
      {
        "model": "simatic cp gprs",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1242-7v22.1.82"
      },
      {
        "model": "simatic rf650r",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "3.0"
      },
      {
        "model": "simatic cp",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "443-13.2.17"
      },
      {
        "model": "simatic cp",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15431.2.1"
      },
      {
        "model": "simatic cm1542",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1.2"
      },
      {
        "model": "scalance w700",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "6.1"
      },
      {
        "model": "extension unit profinet",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "22?1.1.1"
      },
      {
        "model": "extension unit profinet",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "19?1.1.1"
      },
      {
        "model": "extension unit profinet",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15?1.1.1"
      },
      {
        "model": "extension unit profinet",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "12?1.1.1"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp 343 1 std",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp 1542sp 1 irc",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp 1543sp 1",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp 1543 1",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic rf650r",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic rf680r",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic rf685r",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp 1616",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp 1604",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic dk 16xx pn io",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "scalance x200",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp 343 1 lean",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "scalance x200 irt",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "scalance x300",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "scalance x408",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "scalance x414",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "scalance xm400",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "scalance xr500",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "scalance w700",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "scalance m 800",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "scalance s615",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "softnet profinet io",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp 343 1 adv",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "ie pb link",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "ie as i link pn io",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic teleservice adapter standard modem",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic teleservice adapter ie basic modem",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic teleservice adapter ie advanced modem",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sitop psu8600",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "ups1600 profinet",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200al",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200ecopn",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200m",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp 443 1 std",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200mp",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200pro",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200s",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200sp",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "pn pn coupler",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "dk standard ethernet controller",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "ek ertec 200p pn io",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "ek ertec 200 pn io",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 200 smart",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 300",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp 443 1 adv",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 400",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 1200",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 1500",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 1500 controller",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic winac rtx 2010",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sirius act 3su1",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sirius soft starter 3rw44 pn",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sirius motor starter m200d profinet",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simocode pro v profinet",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics dcm",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp 443 1 opc ua",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics dcp",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics g110m",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics g120 c p d w pn",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics g130",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics g150",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics s110 w pn",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics s120",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics s150",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics v90 w pn",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simotion",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp 1243 1",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic hmi comfort panels",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic hmi multi panels",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic hmi mobile panels",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cm 1542 1",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp 1542sp 1",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "296c9514-b30d-4fa5-bcdc-9d8b2e9620c4"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-06151"
      },
      {
        "db": "BID",
        "id": "98369"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-004134"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-2680"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201705-574"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_343-1_std_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "3.1.3",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_343-1_std:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_343-1_lean_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "3.1.3",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_343-1_lean:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_343-1_adv_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_343-1_adv:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_443-1_std_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "3.2.17",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_443-1_std:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_443-1_adv_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "3.2.17",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_443-1_adv:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_443-1_opc-ua_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_443-1_opc-ua:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1243-1_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "2.1.82",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1243-1:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_cm_1542-1_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "2.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_cm_1542-1:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1542sp-1_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "1.0.15",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1542sp-1:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1542sp-1_irc_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "1.0.15",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1542sp-1_irc:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1543sp-1_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "1.0.15",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1543sp-1:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1543-1_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "2.1",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1543-1:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_rf650r_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "3.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_rf650r:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_rf680r_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "3.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_rf680r:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_rf685r_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "3.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_rf685r:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1616_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "2.7",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1616:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1604_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "2.7",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1604:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_dk-1616_pn_io_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "2.7",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_dk-1616_pn_io:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x200_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.2",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x200:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x200_irt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.4.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x200_irt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x300_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x300:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x408_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x408:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x414_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "3.10.2",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x414:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xm400_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "6.1",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xm400:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr500_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "6.1",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr500:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_w700_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "6.1",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_w700:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_m-800_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.03",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_m-800:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_s615_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.03",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:softnet_profinet_io_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "14",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:softnet_profinet_io_firmware:14:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:softnet_profinet_io:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:ie\\/pb-link_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "3.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:ie\\/pb-link:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:ie\\/as-i_link_pn_io_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:ie\\/as-i_link_pn_io:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_teleservice_adapter_ie_standard_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_teleservice_adapter_ie_standard:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_teleservice_adapter_ie_basic_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_teleservice_adapter_ie_basic:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_teleservice_adapter_ie_advanced_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_teleservice_adapter_ie_advanced_modem:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sitop_psu8600_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "1.2.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sitop_psu8600:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:ups1600_profinet_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "2.2.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:ups1600_profinet:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200al_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "1.0.2",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200al:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200ecopn_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200ecopn:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200m_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200m:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200mp_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.0.1",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200mp:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200pro_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200pro:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200s_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200s:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200sp_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200sp:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:pn\\/pn_coupler_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:pn\\/pn_coupler:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.1",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:4.1.1:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:dk_standard_ethernet_controller:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:ek-ertec_200p_pn_io_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.4.0",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:ek-ertec_200p_pn_io_firmware:4.4.0:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:ek-ertec_200p_pn_io:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:ek-ertec_200_pn_io_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.2.1",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:ek-ertec_200_pn_io_firmware:4.2.1:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:ek-ertec_200_pn_io:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-200_smart_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "2.3",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-200_smart:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-400_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "6.0.6",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-400:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1200_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.2.1",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1200:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1500_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "2.1",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1500:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1500_software_controller_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "2.1",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1500_software_controller:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_winac_rtx_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "2010",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_winac_rtx_firmware:2010:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_winac_rtx:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sirius_act_3su1_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "1.1.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sirius_act_3su1:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sirius_soft_starter_3rw44_pn_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sirius_soft_starter_3rw44_pn:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sirius_motor_starter_m200d_profinet_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sirius_motor_starter_m200d_profinet:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simocode_pro_v_profinet_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "2.0.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simocode_pro_v_profinet:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_dcm_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "1.4",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_dcm_firmware:1.4:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_dcm_firmware:1.4:sp1:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_dcm:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_dcp_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "1.2",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_dcp_firmware:1.2:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_dcp:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g110m_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.7",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g110m_firmware:4.7:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_g110m:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g120\\(c\\/p\\/d\\)_w._pn_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.7",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g120\\(c\\/p\\/d\\)_w._pn_firmware:4.7:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_g120\\(c\\/p\\/d\\)_w._pn:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g130_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.7",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g130_firmware:4.7:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_g130:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g150_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.7",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g150_firmware:4.7:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_g150:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics__s110_pn_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.4",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics__s110_pn_firmware:4.4:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:_s110_pn:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_s120_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.7",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_s120_firmware:4.7:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_s150_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.7",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_s150_firmware:4.7:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_s150:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_v90_pn_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "1.01",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_v90_pn:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simotion_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.5",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simotion_firmware:4.5:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simotion:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinumerik_828d_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.5",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinumerik_828d_firmware:4.5:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinumerik_828d:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinumerik_840d_sl_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.5",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinumerik_840d_sl_firmware:4.5:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinumerik_840d_sl:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "15.1",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_multi_panels:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "15.1",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_multi_panels:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_mobile_panels:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "15.1",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_mobile_panels:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1243-1_irc_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "2.1.82",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1243-1_irc:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1243-1_iec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1243-1_iec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1243-1_dnp3_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1243-1_dnp3:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_dk-1604_pn_io_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "2.7",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_dk-1604_pn_io:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_tdc_cpu555_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "1.1.1",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_tdc_cpu555:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_tdc_cp51m1_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "1.1.8",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_tdc_cp51m1:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_gh150_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.7",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_gh150_firmware:4.7:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_gl150_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.8",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_gl150_firmware:4.8:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_gm150_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.7",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_gm150_firmware:4.7:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_sl150_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.8",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_sl150_firmware:4.8:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_sm120_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.8",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_sm120_firmware:4.8:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:extension_unit_12_profinet_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "01.01.01",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:extension_unit_12_profinet:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:extension_unit_15_profinet_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "01.01.01",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:extension_unit_15_profinet:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:extension_unit_19_profinet_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "01.01.01",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:extension_unit_19_profinet:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:extension_unit_22_profinet_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "01.01.01",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:extension_unit_22_profinet:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1242-7_gprs_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "2.1.82",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1242-7_gprs:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1243-7_lte\\/us_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "2.1.82",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1243-7_lte\\/us:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1243-8_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "2.1.82",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1243-8:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1626_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "1.1",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1626:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2017-2680"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Duan JinTong, Ma ShaoShuai, and Cheng Lei from NSFOCUS Security Team.",
    "sources": [
      {
        "db": "BID",
        "id": "98369"
      }
    ],
    "trust": 0.3
  },
  "cve": "CVE-2017-2680",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 6.1,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 6.5,
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "MEDIUM",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Adjacent Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Complete",
            "baseScore": 6.1,
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2017-2680",
            "impactScore": null,
            "integrityImpact": "None",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "Medium",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 6.1,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 6.5,
            "id": "CNVD-2017-06151",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 6.1,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 6.5,
            "id": "296c9514-b30d-4fa5-bcdc-9d8b2e9620c4",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.2,
            "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 6.1,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 6.5,
            "id": "VHN-110883",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:A/AC:L/AU:N/C:N/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 2.8,
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Adjacent Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 6.5,
            "baseSeverity": "Medium",
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2017-2680",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2017-2680",
            "trust": 1.8,
            "value": "MEDIUM"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2017-06151",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201705-574",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "IVD",
            "id": "296c9514-b30d-4fa5-bcdc-9d8b2e9620c4",
            "trust": 0.2,
            "value": "MEDIUM"
          },
          {
            "author": "VULHUB",
            "id": "VHN-110883",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "296c9514-b30d-4fa5-bcdc-9d8b2e9620c4"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-06151"
      },
      {
        "db": "VULHUB",
        "id": "VHN-110883"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-004134"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-2680"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201705-574"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected. SIMATIC CP, SIMATIC RF600, SCALANCE W700, etc. are all industrial automation products from Siemens AG. A denial of service vulnerability exists in several industrial devices from Siemens. Multiple Siemens Products is prone to multiple denial-of-service vulnerabilities. \nAttackers can exploit these issues to cause a denial-of-service condition. Manual restart of the server is required to resume normal operation. SIEMENS SIMATIC CP 343-1 Std, CP 343-1 Lean (All versions), SIMATIC CP 343-1 Adv (All versions), SIMATIC CP 443-1 Std, CP 443-1 Adv (All versions before V3.2.17), SIMATIC CP 443-1 OPC-UA (All versions), SIMATIC CP 1243-1 (All versions before V2.1.82), SIMATIC CP 1243-1 IRC (All versions before V2.1.82), SIMATIC CP 1243-1 IEC (All versions), SIMATIC CP 1243-1 DNP3 (All versions), SIMATIC CM 1542-1 (All versions before V2.0), SIMATIC CP 1542SP-1, CP 1542SP-1 IRC, and CP 1543SP-1 (All versions before to V1.0.15), SIMATIC CP 1543-1 (All versions before V2.1), SIMATIC RF650R, RF680R, RF685R (All versions before V3.0), SIMATIC CP 1616, CP 1604, DK-16xx PN IO (All versions before V2.7), SCALANCE X-200 (All versions before V5.2.2), SCALANCE X200 IRT (All versions before V5.4.0), SCALANCE X-300/X408 (All versions before V4.1.0), SCALANCE X414 (All versions before V3.10.2), SCALANCE XM400, XR500 (All versions before V6.1), SCALANCE W700 (All versions before V6.1), SCALANCE M-800, S615 (All versions before V04.03), Softnet PROFINET IO for PC-based Windows systems (All versions before V14 SP1), IE/PB-Link (All versions before V3.0), IE/AS-i Link PN IO (All versions), SIMATIC Teleservice Adapter Standard Modem, IE Basic, IE Advanced (All versions), SITOP PSU8600 PROFINET (All versions before V1.2.0), SITOP UPS1600 PROFINET (All versions before V2.2.0), SIMATIC ET 200AL (All versions before V1.0.2), SIMATIC ET 200ecoPN (All versions), SIMATIC ET 200M (All versions), SIMATIC ET 200MP (All versions before V4.0.1), SIMATIC ET 200pro (All versions), SIMATIC ET 200S (All versions), SIMATIC ET 200SP (All versions before V4.1.0), SIMATIC PN/PN Coupler (All versions before V4.0), DK Standard Ethernet Controller (All versions before V4.1.1 Patch04), EK-ERTEC 200P PN IO (All versions before V4.4.0 Patch01), EK-ERTEC 200 PN IO (All versions before V4.2.1 Patch03), SIMATIC S7-200 SMART (All versions before V2.3), SIMATIC S7-300 incl. F and T (All versions before V3.X.14), SIMATIC S7-400 PN/DP V6 Incl. F (All versions before V6.0.6), SIMATIC S7-400-H V6 (All versions before V6.0.7), SIMATIC S7-400 PN/DP V7 incl. F (All versions), SIMATIC S7-CPU 410 (All versions before V8.2), SIMATIC S7-1200 incl. F (All versions before V4.2.1), SIMATIC S7-1500 incl. F, T, and TF (All versions before V2.1), SIMATIC S7-1500 Software Controller incl. F (All versions before V2.1), SIMATIC WinAC RTX 2010 incl. F (All versions), SIRIUS ACT 3SU1 interface module PROFINET (All versions), SIRIUS Soft starter 3RW44 PN (All versions), SIRIUS Motor starter M200D PROFINET (All versions), SIMOCODE pro V PROFINET (All versions), SINAMICS DCM (All versions before V1.4 SP1 HF5), SINAMICS DCP (All versions), SINAMICS G110M / G120(C/P/D) w. PN (All versions before V4.7 SP6 HF3), SINAMICS G130 and G150 (All versions before V4.7 HF27 and V4.8 before HF4), SINAMICS S110 w. PN (All versions before V4.4 SP1 HF5), SINAMICS S120 (All versions before V4.7 HF27 and V4.8 before HF4), SINAMICS S150 (All versions before V4.7 HF27 and V4.8 before HF4), SINAMICS V90 w. PN (All versions before V1.1), SIMOTION (All versions before V4.5 HF1), SINUMERIK 828D (All versions before V4.5 SP6 HF2 and V4.7 before SP6 HF8), SINUMERIK 840D sl (All versions before V4.5 SP6 HF8 and V4.7 before SP4 HF1), SIMATIC HMI Comfort Panels, HMI Multi Panels, HMI Mobile Panels (All versions) could be affected by a Denial-of-Service condition induced by a specially crafted PROFINET DCP broadcast (Layer 2 - Ethernet) packet. Siemens SIMATIC S7-200 Smart, etc. Siemens SIMATIC S7-200 Smart is a programmable logic controller (PLC) used in small and medium-sized automation systems. Siemens SIMATIC CP 343-1 Advanced is an Ethernet communication module used to support PROFINET (a new generation of automation bus standard based on industrial Ethernet technology). SIRIUS Motor starter M200D PROFINET is a motor starter. The following products and versions are affected: Siemens Extension Unit 12\\\" PROFINET prior to V01.01.01; Extension Unit 15\\\" PROFINET prior to V01.01.01; Extension Unit 19\\\" PROFINET prior to V01.01.01; Extension Unit 22\\\" PROFINET SIMATIC CP 1242-7 GPRS V2 prior to V2.1.82; SIMATIC CP 1243-7 LTE/US prior to V2.1.82; SIMATIC CP 1243-8 prior to V2.1.82; SIMATIC CP 1626 V1.1 previous version",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2017-2680"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-004134"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-06151"
      },
      {
        "db": "BID",
        "id": "98369"
      },
      {
        "db": "IVD",
        "id": "296c9514-b30d-4fa5-bcdc-9d8b2e9620c4"
      },
      {
        "db": "VULHUB",
        "id": "VHN-110883"
      }
    ],
    "trust": 2.7
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2017-2680",
        "trust": 3.6
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-18-023-02",
        "trust": 2.8
      },
      {
        "db": "SIEMENS",
        "id": "SSA-293562",
        "trust": 2.6
      },
      {
        "db": "SIEMENS",
        "id": "SSA-284673",
        "trust": 2.0
      },
      {
        "db": "BID",
        "id": "98369",
        "trust": 2.0
      },
      {
        "db": "SIEMENS",
        "id": "SSA-546832",
        "trust": 1.7
      },
      {
        "db": "SECTRACK",
        "id": "1038463",
        "trust": 1.7
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-17-129-02",
        "trust": 1.7
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201705-574",
        "trust": 0.9
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-06151",
        "trust": 0.8
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-18-128-01",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-004134",
        "trust": 0.8
      },
      {
        "db": "IVD",
        "id": "296C9514-B30D-4FA5-BCDC-9D8B2E9620C4",
        "trust": 0.2
      },
      {
        "db": "SEEBUG",
        "id": "SSVID-99023",
        "trust": 0.1
      },
      {
        "db": "VULHUB",
        "id": "VHN-110883",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "296c9514-b30d-4fa5-bcdc-9d8b2e9620c4"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-06151"
      },
      {
        "db": "VULHUB",
        "id": "VHN-110883"
      },
      {
        "db": "BID",
        "id": "98369"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-004134"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-2680"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201705-574"
      }
    ]
  },
  "id": "VAR-201705-3220",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "296c9514-b30d-4fa5-bcdc-9d8b2e9620c4"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-06151"
      },
      {
        "db": "VULHUB",
        "id": "VHN-110883"
      }
    ],
    "trust": 1.5351787667924528
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "296c9514-b30d-4fa5-bcdc-9d8b2e9620c4"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-06151"
      }
    ]
  },
  "last_update_date": "2023-12-18T12:51:14.128000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-293562",
        "trust": 0.8,
        "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf"
      },
      {
        "title": "Patch for a number of Siemens products with a denial of service vulnerability (CNVD-2017-06151)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchinfo/show/93364"
      },
      {
        "title": "Multiple Siemens Product security vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=70052"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-06151"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-004134"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201705-574"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-400",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-20",
        "trust": 0.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-110883"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-004134"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-2680"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.8,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-18-023-02"
      },
      {
        "trust": 2.0,
        "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdf"
      },
      {
        "trust": 1.7,
        "url": "http://www.securityfocus.com/bid/98369"
      },
      {
        "trust": 1.7,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf"
      },
      {
        "trust": 1.7,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf"
      },
      {
        "trust": 1.7,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-284673.pdf"
      },
      {
        "trust": 1.7,
        "url": "http://www.securitytracker.com/id/1038463"
      },
      {
        "trust": 1.1,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-17-129-02"
      },
      {
        "trust": 0.9,
        "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf"
      },
      {
        "trust": 0.8,
        "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-2680"
      },
      {
        "trust": 0.8,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-18-128-01"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2017-2680"
      },
      {
        "trust": 0.6,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-17-129-02"
      },
      {
        "trust": 0.3,
        "url": "http://subscriber.communications.siemens.com/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-06151"
      },
      {
        "db": "VULHUB",
        "id": "VHN-110883"
      },
      {
        "db": "BID",
        "id": "98369"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-004134"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-2680"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201705-574"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "296c9514-b30d-4fa5-bcdc-9d8b2e9620c4"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-06151"
      },
      {
        "db": "VULHUB",
        "id": "VHN-110883"
      },
      {
        "db": "BID",
        "id": "98369"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-004134"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-2680"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201705-574"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2017-05-09T00:00:00",
        "db": "IVD",
        "id": "296c9514-b30d-4fa5-bcdc-9d8b2e9620c4"
      },
      {
        "date": "2017-05-09T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2017-06151"
      },
      {
        "date": "2017-05-11T00:00:00",
        "db": "VULHUB",
        "id": "VHN-110883"
      },
      {
        "date": "2017-05-08T00:00:00",
        "db": "BID",
        "id": "98369"
      },
      {
        "date": "2017-06-16T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2017-004134"
      },
      {
        "date": "2017-05-11T01:29:05.400000",
        "db": "NVD",
        "id": "CVE-2017-2680"
      },
      {
        "date": "2017-05-12T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201705-574"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2017-05-09T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2017-06151"
      },
      {
        "date": "2020-09-29T00:00:00",
        "db": "VULHUB",
        "id": "VHN-110883"
      },
      {
        "date": "2018-05-09T14:00:00",
        "db": "BID",
        "id": "98369"
      },
      {
        "date": "2018-05-10T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2017-004134"
      },
      {
        "date": "2022-04-12T18:29:01.937000",
        "db": "NVD",
        "id": "CVE-2017-2680"
      },
      {
        "date": "2022-02-11T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201705-574"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote or local",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201705-574"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Siemens Service disruption in products  (DoS) Vulnerabilities",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-004134"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "resource management error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201705-574"
      }
    ],
    "trust": 0.6
  }
}