Vulnerabilites related to hp - integrated_lights-out_4
Vulnerability from fkie_nvd
Published
2017-05-11 14:29
Modified
2024-11-21 02:33
Summary
A potential security vulnerability has been identified with HP Integrated Lights-Out 4 (iLO 4) firmware version 2.11 and later, but prior to version 2.30. The vulnerability could be exploited remotely resulting in Denial of Service (DoS). Note this was originally published in 2015 however the CVE entry was added in 2020.
Impacted products



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "652B9F99-3C89-42F7-A194-E1AC82B57CCF",
              "versionEndExcluding": "2.30",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:integrated_lights-out_4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "47EEB8DA-1CDD-428C-988C-249E2816F18C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A potential security vulnerability has been identified with HP Integrated Lights-Out 4 (iLO 4) firmware version 2.11 and later, but prior to version 2.30. The vulnerability could be exploited remotely resulting in Denial of Service (DoS). Note this was originally published in 2015 however the CVE entry was added in 2020."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una posible vulnerabilidad de seguridad con el firmware HP Integrated Lights-Out 4 (iLO 4) versi\u00f3n 2.11 y posterior, pero anterior a la versi\u00f3n 2.30. La vulnerabilidad podr\u00eda explotarse a distancia, lo que dar\u00eda lugar a una denegaci\u00f3n de servicio (DoS). Note que esto fue publicado originalmente en 2015, sin embargo la entrada CVE fue a\u00f1adida en 2020"
    }
  ],
  "id": "CVE-2015-5436",
  "lastModified": "2024-11-21T02:33:00.383",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 7.8,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2017-05-11T14:29:46.997",
  "references": [
    {
      "source": "hp-security-alert@hp.com",
      "url": "https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-c04806165"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-c04806165"
    }
  ],
  "sourceIdentifier": "hp-security-alert@hp.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-05-25 15:15
Modified
2024-11-21 06:00
Summary
A remote dom xss, crlf injection vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_4:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4E25CDBB-3C9D-4AAB-BA21-0346546AA369",
              "versionEndExcluding": "2.78",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F05331F2-DF6B-4CD3-9BA4-B97A34746509",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_5:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD145EB4-A7F3-4A6D-A782-080507068D45",
              "versionEndExcluding": "2.44",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:proliant_bl460c_gen10_server_blade:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "03E00679-A2A7-4A51-9764-462BF479F423",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl120_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B553E44A-A209-49CA-A914-CC1FE51D90D8",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl160_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "666AAAE5-83AB-4018-891D-2FC69AE6AD65",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl180_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5DD32E61-4FFE-4ECF-9582-B96D1513C706",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl20_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3BDF28CD-B01A-4C31-B62A-0472AD96D255",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl325_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB5F7BC4-EAA0-47EB-A66A-B5BC60620E1F",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl325_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "58196CA6-BA67-4361-8056-B52B1A323E5D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl360_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F5FC76C8-44FC-4BCC-95C1-0717126BBE2A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl380_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BFD8AB8C-D5BA-4312-9E7A-48ECB09F3C16",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl385_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CBF5E039-BBBF-42A4-8F57-CB2B7E65D763",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl385_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "306B6EC0-C471-48B6-858C-93A4A6CB976D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl560_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6A16D30B-D064-4EEC-9628-7B64B63CE2CA",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl580_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A367F8FE-8500-4512-831A-408BB0772586",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml110_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "358CD445-B506-4EE9-A282-76A790EA4583",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml30_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D857745-3DBE-4B0A-ACE3-0159EB3D0121",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml350_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9DB2958-DDCD-4ACA-B9C1-F7914622E36B",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl170r_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F8A0F022-C271-4DB6-A12E-1A2357C0BFE9",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl190r_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "29DEE638-BD6B-4B70-ABEE-AFD8FDA99F45",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl230k_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C7B1F484-2258-4326-AEFA-725BD8EFE6CD",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl270d_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "00D87480-CB71-4BB0-A034-41B3AA9F10A4",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl450_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "81B8CA7A-F115-4932-A932-F61180E79A72",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_2600:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2A13A066-1BC1-43D3-BBCC-499F1C1C864A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_325:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE4D8959-5623-4211-BE1B-80E6557D61F2",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFA60F7D-DD77-4DED-B13B-C59025FCF3A2",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10_g:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C077CA8B-F758-4D35-BFBA-9350586BBB91",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10_h:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D2DAFA4-2B9B-455D-9ABD-28D3E36859F0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A remote dom xss, crlf injection vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
    },
    {
      "lang": "es",
      "value": "Se detect\u00f3 una vulnerabilidad de un xss dom y una inyecci\u00f3n remota de crlf en HPE Integrated Lights-Out 4 (iLO 4);\u0026#xa0;HPE SimpliVity 380 Gen9;\u0026#xa0;HPE Integrated Lights-Out 5 (iLO 5) para servidores HPE Gen10;\u0026#xa0;HPE SimpliVity 380 Gen10;\u0026#xa0;HPE SimpliVity 2600;\u0026#xa0;HPE SimpliVity 380 Gen10 G;\u0026#xa0;HPE SimpliVity 325;\u0026#xa0;Versiones de HPE SimpliVity 380 Gen10 H: anterior a versi\u00f3n 2.78"
    }
  ],
  "id": "CVE-2021-29209",
  "lastModified": "2024-11-21T06:00:49.823",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "LOW",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "NONE",
          "baseScore": 3.5,
          "confidentialityImpact": "NONE",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 6.8,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 4.8,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "HIGH",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.7,
        "impactScore": 2.7,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-05-25T15:15:07.443",
  "references": [
    {
      "source": "security-alert@hpe.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
    }
  ],
  "sourceIdentifier": "security-alert@hpe.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-74"
        },
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-01-05 15:15
Modified
2024-11-21 05:36
Summary
A potential security vulnerability has been identified in HPE Integrated Lights-Out 5 (iLO 5) and Integrated Lights-Out 4 (iLO 4) firmware. The vulnerability could be remotely exploited to disclose the serial number and other information.
Impacted products
Vendor Product Version
hp integrated_lights-out_4 *
hp apollo_4200_gen9_server -
hp convergedsystem_cs700 -
hp convergedsystem_cs700x -
hp proliant_bl420c_gen8_server -
hp proliant_bl460c_gen8_server_blade -
hp proliant_bl460c_gen9_server_blade -
hp proliant_bl465c_gen8_server_blade -
hp proliant_bl660c_gen8_server_blade -
hp proliant_bl660c_gen9_server -
hp proliant_dl120_gen9_server -
hp proliant_dl160_gen8_server -
hp proliant_dl160_gen9_server -
hp proliant_dl180_gen9_server -
hp proliant_dl320e_gen8_server -
hp proliant_dl320e_gen8_v2_server -
hp proliant_dl360_gen9_server -
hp proliant_dl360e_gen8_server -
hp proliant_dl360p_gen8_server -
hp proliant_dl380_gen9_server -
hp proliant_dl380e_gen8_server -
hp proliant_dl380p_gen8_server -
hp proliant_dl385p_gen8_\(amd\) -
hp proliant_dl560_gen8_server -
hp proliant_dl560_gen9_server -
hp proliant_dl580_gen8_server -
hp proliant_dl580_gen9_server -
hp proliant_dl60_gen9_server -
hp proliant_dl80_gen9_server -
hp proliant_microserver_gen8 -
hp proliant_ml110_gen9_server -
hp proliant_ml30_gen9_server -
hp proliant_ml310e_gen8_server -
hp proliant_ml310e_gen8_v2_server -
hp proliant_ml350_gen9_server -
hp proliant_ml350e_gen8_server -
hp proliant_ml350e_gen8_v2_server -
hp proliant_ml350p_gen8_server -
hp proliant_sl210t_gen8_server -
hp proliant_sl230s_gen8_server -
hp proliant_sl250s_gen8_server -
hp proliant_sl270s_gen8_se_server -
hp proliant_sl270s_gen8_server -
hp proliant_sl4540_gen8_3_node_server -
hp proliant_ws460c_gen8_graphics_server_blade -
hp proliant_ws460c_gen9_graphics_server_blade -
hp proliant_xl170r_gen9_server -
hp proliant_xl190r_gen9_server -
hp proliant_xl220a_gen8_v2_server -
hp proliant_xl230a_gen9_server -
hp proliant_xl250a_gen9_server -
hp proliant_xl450_gen9_server -
hp proliant_xl730f_gen9_server -
hp proliant_xl740f_gen9_server -
hp proliant_xl750f_gen9_server -
hp synergy_480_gen9_compute_module -
hp integrated_lights-out_5 *
hp apollo_4200_gen10_server -
hp apollo_4510_system -
hp apollo_r2000_chassis -
hp convergedsystem_cs700 -
hp convergedsystem_cs700x -
hp proliant_bl460c_gen10_server_blade -
hp proliant_dl120_gen10_server -
hp proliant_dl160_gen10_server -
hp proliant_dl180_gen10_server -
hp proliant_dl20_gen10_server -
hp proliant_dl325_gen10_plus_server -
hp proliant_dl325_gen10_server -
hp proliant_dl360_gen10_server -
hp proliant_dl380_gen10_server -
hp proliant_dl385_gen10_plus_server -
hp proliant_dl385_gen10_server -
hp proliant_dl560_gen10_server -
hp proliant_dl580_gen10_server -
hp proliant_ml110_gen10_server -
hp proliant_ml30_gen10_server -
hp proliant_ml350_gen10_server -
hp proliant_xl170r_gen10_server -
hp proliant_xl190r_gen10_server -
hp proliant_xl230k_gen10_server -
hp proliant_xl270d_gen10_server -
hp proliant_xl450_gen10_server -
hp synergy_480_gen10_compute_module -
hp synergy_660_gen10_compute_module -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_4:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "728B6275-69A0-4235-B877-A80EAA5AE662",
              "versionEndExcluding": "2.76",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:apollo_4200_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8C145C31-ED51-48CA-AC14-53A46F3DA0B9",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:convergedsystem_cs700:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "07452929-D568-4D48-9480-6F03AD39EBC8",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:convergedsystem_cs700x:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "72DE103E-83D9-4A9C-BB91-F876448443CA",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_bl420c_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE085EBF-9338-4F4D-BA6D-DF71EB55809D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_bl460c_gen8_server_blade:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F7C5EE27-AC35-490B-AF26-FDA261AA03B5",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_bl460c_gen9_server_blade:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0BB98203-AFC1-489F-BA7D-F66E3275774A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_bl465c_gen8_server_blade:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E16A3168-F12A-47D9-B80B-11815DDAA24E",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_bl660c_gen8_server_blade:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D5E3FC67-8EBC-4EE9-B518-561602DD617F",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_bl660c_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "66EB270B-9289-4D3D-91A8-751CF2C62BD5",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl120_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2483ED79-0132-4484-808B-8DA9F2F9CE1E",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl160_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "35D7105B-54F9-480D-95B6-9BFACD405450",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl160_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AFADFAB1-F9C7-4613-AB00-6088A54B2984",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl180_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CFBF3AAB-5A41-498D-8934-5069086AF0A4",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl320e_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A10ED119-2AFB-4A19-8EC9-11DD00C771C3",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl320e_gen8_v2_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2CB4D64F-C78D-4A5A-8213-85607DD5DC3D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl360_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5562E797-E2BA-49A7-A7FD-F345F3B3EDC1",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl360e_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE32C218-B3DC-4915-A170-D41EA356B37F",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl360p_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "971D98CB-488B-475E-834F-D7F2C2D15618",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl380_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B4176A85-6BA7-4A49-95A6-759655FCE437",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl380e_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A2B60FD7-710F-4596-AC1E-C92BE1F73185",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl380p_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "089A9561-E2E3-4E6C-8E2A-3E0559306B9C",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl385p_gen8_\\(amd\\):-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0DF8D7D0-50A7-45CE-8C57-2BF809D6D467",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl560_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1B0B6A0E-982B-49F8-9CD8-675599E801DA",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl560_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7C250444-6DCB-492C-9C09-BCB4D8F9522E",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl580_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DD283162-B57B-4041-A36D-70C15C5CAD2B",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl580_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0E11FBED-28C9-4D77-BCE4-847115EC5A56",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl60_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "03D1BA51-A089-4CB6-8B7A-44B29BE38D65",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl80_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "501CE644-836D-45D7-A525-00443E496279",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_microserver_gen8:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F2D4A053-A170-41E8-85A6-6D7C71942130",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml110_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6C226593-97C5-49C4-9906-88430D35A1A9",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml30_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B479287E-D58C-432F-9B76-A6C75C4C1539",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml310e_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "72BD3DC2-1148-47E8-956B-379214CB0847",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml310e_gen8_v2_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "34846E13-5492-4B43-BFF7-DD68DC044DF2",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml350_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "22E0FE3B-24DB-416D-93FF-98CD64538A99",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml350e_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "16078B36-0484-43E1-91EB-507403E469FB",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml350e_gen8_v2_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "27B69F59-24E1-40E7-AD2A-D5C6A4E9D75C",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml350p_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A3DAD01F-2D0C-4055-9B68-73100C02A63E",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_sl210t_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4976BD59-4074-4EB5-97EC-FA3E50C83245",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_sl230s_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "88C7E69C-68FC-4BB5-845E-AC78AE6213E9",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_sl250s_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "07646416-DC91-44C2-AEC3-2F979C9C89B5",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_sl270s_gen8_se_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6FEF9B53-21AA-43F8-82B6-476F04D0498D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_sl270s_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8F77695B-AE96-4A78-B818-451408BFED3A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_sl4540_gen8_3_node_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2A191A1E-ED89-4E71-A113-CAB3148D9771",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ws460c_gen8_graphics_server_blade:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "61A6ED7F-9F9C-47E1-B947-36175C7864E3",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ws460c_gen9_graphics_server_blade:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B60147E9-D2AA-4B5C-9975-F27921BCF547",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl170r_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9F3A643B-F7DA-4239-BF5D-CCB2ECD4AB46",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl190r_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6C3E0225-79B8-47EE-AA0F-F35D69FA2905",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl220a_gen8_v2_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B33E1DFC-4274-4488-9D64-E37D0CC4B055",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl230a_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A8FC258B-754A-4372-ADF1-1F2BBDA8CE54",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl250a_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D871D279-38D4-48EE-8966-C2B686390E1A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl450_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A165E3C1-14E8-421E-807A-3888B204E105",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl730f_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EC8A90D2-7C7F-42FA-9F35-34C2D9612C03",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl740f_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B29CFA7E-6485-4FA0-816B-0CCA98BB77BE",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl750f_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AB222D02-E0CD-4BD2-BFED-50FC0EB8BA48",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:synergy_480_gen9_compute_module:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9F9CD561-6392-4F85-9D81-7A39BA8E518B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_5:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "53905D4D-26A8-49B2-9AB5-C8E04B2B7712",
              "versionEndExcluding": "2.31",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:apollo_4200_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F7E4EA1D-8ACB-4C6C-AB96-80BC8FD71FB3",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:apollo_4510_system:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D87366D-D719-46A8-AE28-455155C8D359",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:apollo_r2000_chassis:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9311154A-E0EF-46B3-B8D0-6ED540029684",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:convergedsystem_cs700:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "07452929-D568-4D48-9480-6F03AD39EBC8",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:convergedsystem_cs700x:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "72DE103E-83D9-4A9C-BB91-F876448443CA",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_bl460c_gen10_server_blade:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "03E00679-A2A7-4A51-9764-462BF479F423",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl120_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B553E44A-A209-49CA-A914-CC1FE51D90D8",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl160_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "666AAAE5-83AB-4018-891D-2FC69AE6AD65",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl180_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5DD32E61-4FFE-4ECF-9582-B96D1513C706",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl20_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3BDF28CD-B01A-4C31-B62A-0472AD96D255",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl325_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB5F7BC4-EAA0-47EB-A66A-B5BC60620E1F",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl325_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "58196CA6-BA67-4361-8056-B52B1A323E5D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl360_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F5FC76C8-44FC-4BCC-95C1-0717126BBE2A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl380_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BFD8AB8C-D5BA-4312-9E7A-48ECB09F3C16",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl385_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CBF5E039-BBBF-42A4-8F57-CB2B7E65D763",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl385_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "306B6EC0-C471-48B6-858C-93A4A6CB976D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl560_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6A16D30B-D064-4EEC-9628-7B64B63CE2CA",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl580_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A367F8FE-8500-4512-831A-408BB0772586",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml110_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "358CD445-B506-4EE9-A282-76A790EA4583",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml30_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D857745-3DBE-4B0A-ACE3-0159EB3D0121",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml350_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9DB2958-DDCD-4ACA-B9C1-F7914622E36B",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl170r_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F8A0F022-C271-4DB6-A12E-1A2357C0BFE9",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl190r_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "29DEE638-BD6B-4B70-ABEE-AFD8FDA99F45",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl230k_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C7B1F484-2258-4326-AEFA-725BD8EFE6CD",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl270d_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "00D87480-CB71-4BB0-A034-41B3AA9F10A4",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl450_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "81B8CA7A-F115-4932-A932-F61180E79A72",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:synergy_480_gen10_compute_module:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0BD2C870-A12D-470A-94A7-DD31C4E8AB0B",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:synergy_660_gen10_compute_module:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "44B8A537-DF37-4D7C-8290-5254A788D087",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A potential security vulnerability has been identified in HPE Integrated Lights-Out 5 (iLO 5) and Integrated Lights-Out 4 (iLO 4) firmware. The vulnerability could be remotely exploited to disclose the serial number and other information."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad de seguridad potencial en el firmware HPE Integrated Lights-Out versi\u00f3n 5 (iLO 5) e Integrated Lights-Out versi\u00f3n 4 (iLO 4).\u0026#xa0;La vulnerabilidad podr\u00eda ser explotada remotamente para divulgar el n\u00famero de serie y otra informaci\u00f3n"
    }
  ],
  "id": "CVE-2020-7202",
  "lastModified": "2024-11-21T05:36:49.233",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 5.0,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 5.3,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 1.4,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-01-05T15:15:14.077",
  "references": [
    {
      "source": "security-alert@hpe.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04069en_us"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04069en_us"
    }
  ],
  "sourceIdentifier": "security-alert@hpe.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2013-11-18 03:55
Modified
2024-11-21 01:56
Severity ?
Summary
Unspecified vulnerability in HP Integrated Lights-Out 4 (iLO4) with firmware before 1.32 allows remote authenticated users to obtain sensitive information via unknown vectors.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "17EDFBC8-40D5-405F-9E53-45D39AFD06AF",
              "versionEndIncluding": "1.27a",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_firmware:1.10:*:*:*:*:*:*:*",
              "matchCriteriaId": "F3B75737-F8DF-4467-87E6-B3D7D296AF69",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_firmware:1.15:*:*:*:*:*:*:*",
              "matchCriteriaId": "FDE41EB1-8AAE-40F8-A7C0-703283020F0F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_firmware:1.15a:*:*:*:*:*:*:*",
              "matchCriteriaId": "223798D1-6965-4EBF-B731-0AADBC853752",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_firmware:1.16a:*:*:*:*:*:*:*",
              "matchCriteriaId": "03B3C027-295A-4E8D-AC99-89B1DBC9937E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_firmware:1.20a:*:*:*:*:*:*:*",
              "matchCriteriaId": "859702BA-314B-4BC4-8CA6-1432E8831B89",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_firmware:1.26a:*:*:*:*:*:*:*",
              "matchCriteriaId": "58207045-31FF-4B78-832D-A47F49743529",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:integrated_lights-out_4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "47EEB8DA-1CDD-428C-988C-249E2816F18C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Unspecified vulnerability in HP Integrated Lights-Out 4 (iLO4) with firmware before 1.32 allows remote authenticated users to obtain sensitive information via unknown vectors."
    },
    {
      "lang": "es",
      "value": "Vulnerabilidad no especificada en HP Integrated Lights-Out 4 (iLO4) con el firmware anterior a 1.32 que permite a  usuarios autenticados remotos obtener informaci\u00f3n sensible a trav\u00e9s de vectores desconocidos."
    }
  ],
  "id": "CVE-2013-4843",
  "lastModified": "2024-11-21T01:56:31.127",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "NONE",
          "baseScore": 6.8,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:S/C:C/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 8.0,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ]
  },
  "published": "2013-11-18T03:55:05.913",
  "references": [
    {
      "source": "hp-security-alert@hp.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay?docId=emr_na-c03996804"
    },
    {
      "source": "hp-security-alert@hp.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay?docId=emr_na-c03996804"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay?docId=emr_na-c03996804"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay?docId=emr_na-c03996804"
    }
  ],
  "sourceIdentifier": "hp-security-alert@hp.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2013-11-18 03:55
Modified
2024-11-21 01:56
Severity ?
Summary
Cross-site scripting (XSS) vulnerability in HP Integrated Lights-Out 4 (iLO4) with firmware before 1.32 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "17EDFBC8-40D5-405F-9E53-45D39AFD06AF",
              "versionEndIncluding": "1.27a",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_firmware:1.10:*:*:*:*:*:*:*",
              "matchCriteriaId": "F3B75737-F8DF-4467-87E6-B3D7D296AF69",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_firmware:1.15:*:*:*:*:*:*:*",
              "matchCriteriaId": "FDE41EB1-8AAE-40F8-A7C0-703283020F0F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_firmware:1.15a:*:*:*:*:*:*:*",
              "matchCriteriaId": "223798D1-6965-4EBF-B731-0AADBC853752",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_firmware:1.16a:*:*:*:*:*:*:*",
              "matchCriteriaId": "03B3C027-295A-4E8D-AC99-89B1DBC9937E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_firmware:1.20a:*:*:*:*:*:*:*",
              "matchCriteriaId": "859702BA-314B-4BC4-8CA6-1432E8831B89",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_firmware:1.26a:*:*:*:*:*:*:*",
              "matchCriteriaId": "58207045-31FF-4B78-832D-A47F49743529",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:integrated_lights-out_4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "47EEB8DA-1CDD-428C-988C-249E2816F18C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Cross-site scripting (XSS) vulnerability in HP Integrated Lights-Out 4 (iLO4) with firmware before 1.32 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors."
    },
    {
      "lang": "es",
      "value": "Vulnerabilidad de XSS en HP Integrated Lights-Out 4 (iLO4) con firmware anterior a la versi\u00f3n 1.32 permite a atacantes remotos inyectar script web arbitrario o HTML a trav\u00e9s de vectores sin especificar."
    }
  ],
  "id": "CVE-2013-4842",
  "lastModified": "2024-11-21T01:56:31.017",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 4.3,
          "confidentialityImpact": "NONE",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ]
  },
  "published": "2013-11-18T03:55:05.883",
  "references": [
    {
      "source": "hp-security-alert@hp.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay?docId=emr_na-c03996804"
    },
    {
      "source": "hp-security-alert@hp.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay?docId=emr_na-c03996804"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay?docId=emr_na-c03996804"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay?docId=emr_na-c03996804"
    }
  ],
  "sourceIdentifier": "hp-security-alert@hp.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-05-25 15:15
Modified
2024-11-21 06:00
Summary
A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_4:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4E25CDBB-3C9D-4AAB-BA21-0346546AA369",
              "versionEndExcluding": "2.78",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F05331F2-DF6B-4CD3-9BA4-B97A34746509",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_5:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD145EB4-A7F3-4A6D-A782-080507068D45",
              "versionEndExcluding": "2.44",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:proliant_bl460c_gen10_server_blade:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "03E00679-A2A7-4A51-9764-462BF479F423",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl120_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B553E44A-A209-49CA-A914-CC1FE51D90D8",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl160_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "666AAAE5-83AB-4018-891D-2FC69AE6AD65",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl180_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5DD32E61-4FFE-4ECF-9582-B96D1513C706",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl20_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3BDF28CD-B01A-4C31-B62A-0472AD96D255",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl325_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB5F7BC4-EAA0-47EB-A66A-B5BC60620E1F",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl325_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "58196CA6-BA67-4361-8056-B52B1A323E5D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl360_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F5FC76C8-44FC-4BCC-95C1-0717126BBE2A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl380_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BFD8AB8C-D5BA-4312-9E7A-48ECB09F3C16",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl385_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CBF5E039-BBBF-42A4-8F57-CB2B7E65D763",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl385_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "306B6EC0-C471-48B6-858C-93A4A6CB976D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl560_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6A16D30B-D064-4EEC-9628-7B64B63CE2CA",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl580_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A367F8FE-8500-4512-831A-408BB0772586",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml110_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "358CD445-B506-4EE9-A282-76A790EA4583",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml30_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D857745-3DBE-4B0A-ACE3-0159EB3D0121",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml350_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9DB2958-DDCD-4ACA-B9C1-F7914622E36B",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl170r_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F8A0F022-C271-4DB6-A12E-1A2357C0BFE9",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl190r_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "29DEE638-BD6B-4B70-ABEE-AFD8FDA99F45",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl230k_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C7B1F484-2258-4326-AEFA-725BD8EFE6CD",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl270d_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "00D87480-CB71-4BB0-A034-41B3AA9F10A4",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl450_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "81B8CA7A-F115-4932-A932-F61180E79A72",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_2600:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2A13A066-1BC1-43D3-BBCC-499F1C1C864A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_325:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE4D8959-5623-4211-BE1B-80E6557D61F2",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFA60F7D-DD77-4DED-B13B-C59025FCF3A2",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10_g:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C077CA8B-F758-4D35-BFBA-9350586BBB91",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10_h:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D2DAFA4-2B9B-455D-9ABD-28D3E36859F0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
    },
    {
      "lang": "es",
      "value": "Se detect\u00f3 una vulnerabilidad  de tipo xss remota en HPE Integrated Lights-Out 4 (iLO 4);\u0026#xa0;HPE SimpliVity 380 Gen9;\u0026#xa0;HPE Integrated Lights-Out 5 (iLO 5) para servidores HPE Gen10;\u0026#xa0;HPE SimpliVity 380 Gen10;\u0026#xa0;HPE SimpliVity 2600;\u0026#xa0;HPE SimpliVity 380 Gen10 G;\u0026#xa0;HPE SimpliVity 325;\u0026#xa0;Versiones de HPE SimpliVity 380 Gen10 H: anterior a versi\u00f3n 2.78"
    }
  ],
  "id": "CVE-2021-29211",
  "lastModified": "2024-11-21T06:00:50.067",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "LOW",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "NONE",
          "baseScore": 3.5,
          "confidentialityImpact": "NONE",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 6.8,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 4.8,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "HIGH",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.7,
        "impactScore": 2.7,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-05-25T15:15:07.497",
  "references": [
    {
      "source": "security-alert@hpe.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
    }
  ],
  "sourceIdentifier": "security-alert@hpe.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2023-03-22 06:15
Modified
2024-11-21 07:54
Summary
A remote Cross-site Scripting vulnerability was discovered in HPE Integrated Lights-Out 6 (iLO 6), Integrated Lights-Out 5 (iLO 5) and Integrated Lights-Out 4 (iLO 4). HPE has provided software updates to resolve this vulnerability in HPE Integrated Lights-Out.
Impacted products
Vendor Product Version
hp integrated_lights-out_4 *
hpe apollo_4200_gen9_server -
hpe apollo_r2000_chassis -
hpe proliant_bl420c_gen8_server -
hpe proliant_bl460c_gen8_server_blade -
hpe proliant_bl460c_gen9_server_blade -
hpe proliant_bl465c_gen8_server_blade -
hpe proliant_bl660c_gen8_server_blade -
hpe proliant_bl660c_gen9_server -
hpe proliant_dl120_gen9_server -
hpe proliant_dl160_gen8_server -
hpe proliant_dl160_gen9_server -
hpe proliant_dl180_gen9_server -
hpe proliant_dl20_gen9_server -
hpe proliant_dl320e_gen8_server -
hpe proliant_dl320e_gen8_v2_server -
hpe proliant_dl360_gen9_server -
hpe proliant_dl360e_gen8_server -
hpe proliant_dl360p_gen8_server -
hpe proliant_dl380_gen9_server -
hpe proliant_dl380e_gen8_server -
hpe proliant_dl380p_gen8_server -
hpe proliant_dl385p_gen8_\(amd\) -
hpe proliant_dl560_gen8_server -
hpe proliant_dl560_gen9_server -
hpe proliant_dl580_gen8_server -
hpe proliant_dl580_gen9_server -
hpe proliant_dl60_gen9_server -
hpe proliant_dl80_gen9_server -
hpe proliant_microserver_gen8 -
hpe proliant_ml110_gen9_server -
hpe proliant_ml30_gen9_server -
hpe proliant_ml310e_gen8_server -
hpe proliant_ml310e_gen8_v2_server -
hpe proliant_ml350_gen9_server -
hpe proliant_ml350e_gen8_server -
hpe proliant_ml350e_gen8_v2_server -
hpe proliant_ml350p_gen8_server -
hpe proliant_sl210t_gen8_server -
hpe proliant_sl230s_gen8_server -
hpe proliant_sl250s_gen8_server -
hpe proliant_sl270s_gen8_se_server -
hpe proliant_sl270s_gen8_server -
hpe proliant_ws460c_gen8_graphics_server_blade -
hpe proliant_ws460c_gen9_graphics_server_blade -
hpe proliant_xl170r_gen9_server -
hpe proliant_xl190r_gen9_server -
hpe proliant_xl220a_gen8_v2_server -
hpe proliant_xl230a_gen9_server -
hpe proliant_xl230b_gen9_server -
hpe proliant_xl250a_gen9_server -
hpe proliant_xl270d_gen9_special_server -
hpe proliant_xl450_gen9_server -
hpe proliant_xl730f_gen9_server -
hpe proliant_xl740f_gen9_server -
hpe proliant_xl750f_gen9_server -
hpe storeeasy_1430_storage -
hpe storeeasy_1440_storage -
hpe storeeasy_1450_storage -
hpe storeeasy_1530_storage -
hpe storeeasy_1540_storage -
hpe storeeasy_1550_storage -
hpe storeeasy_1630_storage -
hpe storeeasy_1640_storage -
hpe storeeasy_1650_expanded_storage -
hpe storeeasy_1650_storage -
hpe storeeasy_1830_storage -
hpe storeeasy_1840_storage -
hpe storeeasy_1850_storage -
hpe storeeasy_3830_gateway_storage -
hpe storeeasy_3830_gateway_storage_blade -
hpe storeeasy_3840_gateway_storage -
hpe storeeasy_3840_gateway_storage_blade -
hpe storeeasy_3850_gateway_single_node_upgrade -
hpe storeeasy_3850_gateway_storage -
hpe storeeasy_3850_gateway_storage_blade -
hpe storevirtual_3000_file_controller -
hpe synergy_480_gen9_compute_module -
hpe synergy_620_gen9_compute_module -
hpe synergy_660_gen9_compute_module -
hpe synergy_680_gen9_compute_module -
hp integrated_lights-out_5 *
hpe apollo_4200_gen10_plus_system -
hpe apollo_4200_gen10_server -
hpe apollo_4510_gen10_system -
hpe apollo_6500_gen10_plus_system -
hpe apollo_6500_gen10_system -
hpe apollo_n2600_gen10_plus -
hpe apollo_n2800_gen10_plus -
hpe apollo_r2200_gen10 -
hpe apollo_r2600_gen10 -
hpe apollo_r2800_gen10 -
hpe edgeline_e920_server_blade -
hpe edgeline_e920d_server_blade -
hpe edgeline_e920t_server_blade -
hpe proliant_bl460c_gen10_server_blade -
hpe proliant_dl120_gen10_server -
hpe proliant_dl160_gen10_server -
hpe proliant_dl180_gen10_server -
hpe proliant_dl20_gen10_plus_server -
hpe proliant_dl20_gen10_server -
hpe proliant_dl325_gen10_plus_server -
hpe proliant_dl325_gen10_server -
hpe proliant_dl345_gen10_plus_server -
hpe proliant_dl360_gen10_plus_server -
hpe proliant_dl360_gen10_server -
hpe proliant_dl365_gen10_plus_server -
hpe proliant_dl380_gen10_plus_server -
hpe proliant_dl380_gen10_server -
hpe proliant_dl385_gen10_plus_server -
hpe proliant_dl385_gen10_plus_v2_server -
hpe proliant_dl385_gen10_server -
hpe proliant_dl560_gen10_server -
hpe proliant_dl580_gen10_server -
hpe proliant_dx170r_gen10_server -
hpe proliant_dx190r_gen10_server -
hpe proliant_dx220n_gen10_plus_server -
hpe proliant_dx325_gen10_plus_v2_server -
hpe proliant_dx360_gen10_plus_server -
hpe proliant_dx360_gen10_server -
hpe proliant_dx380_gen10_plus_server -
hpe proliant_dx380_gen10_server -
hpe proliant_dx385_gen10_plus_server -
hpe proliant_dx385_gen10_plus_v2_server -
hpe proliant_dx4200_gen10_server -
hpe proliant_dx560_gen10_server -
hpe proliant_e910_server_blade -
hpe proliant_e910t_server_blade -
hpe proliant_ml110_gen10_server -
hpe proliant_ml30_gen10_plus_server -
hpe proliant_ml350_gen10_server -
hpe proliant_xl170r_gen10_server -
hpe proliant_xl190r_gen10_server -
hpe proliant_xl220n_gen10_plus_server -
hpe proliant_xl225n_gen10_plus_1u_node -
hpe proliant_xl230k_gen10_server -
hpe proliant_xl270d_gen10_server -
hpe proliant_xl290n_gen10_plus_server -
hpe proliant_xl450_gen10_server -
hpe proliant_xl645d_gen10_plus_server -
hpe proliant_xl675d_gen10_plus_server -
hpe storage_file_controller -
hpe storage_performance_file_controller -
hpe storeeasy_1460_storage -
hpe storeeasy_1560_storage -
hpe storeeasy_1660_expanded_storage -
hpe storeeasy_1660_performance_storage -
hpe storeeasy_1660_storage -
hpe storeeasy_1860_performance_storage -
hpe storeeasy_1860_storage -
hpe synergy_480_gen10_compute_module -
hpe synergy_480_gen10_plus_compute_module -
hpe synergy_660_gen10_compute_module -
hp integrated_lights-out_6 *
hpe proliant_dl320_gen11_server -
hpe proliant_dl325_gen11_server -
hpe proliant_dl345_gen11_server -
hpe proliant_dl360_gen11_server -
hpe proliant_dl365_gen11_server -
hpe proliant_dl380_gen11_server -
hpe proliant_dl385_gen11_server -
hpe proliant_ml350_gen11_server -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_4:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A2AE4806-D70C-4D80-A898-405A3BC7D81C",
              "versionEndExcluding": "2.82",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hpe:apollo_4200_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C20D38E9-B2EA-4ECC-B9EC-D29BB249AC77",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:apollo_r2000_chassis:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F9724EB6-9693-4F0D-B507-B962D64B2E8A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_bl420c_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2E3C760C-2DAF-45CE-972B-B86D963B16BC",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_bl460c_gen8_server_blade:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B110E689-1823-42D6-91E6-81115A2CB048",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_bl460c_gen9_server_blade:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D230E7A-D852-4040-83CF-164AA3233F00",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_bl465c_gen8_server_blade:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1C786E99-CDC8-4265-A05B-931602A4E10B",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_bl660c_gen8_server_blade:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "91276F1E-6475-479D-857C-689E210116B8",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_bl660c_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E2E685C0-E20A-4E95-A76F-8D18AF92C0F4",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl120_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C6B65F98-15A8-48FA-A836-97430AF183EB",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl160_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "346996C3-E131-4BE0-9261-E32D0567F795",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl160_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E1AD90B1-F95C-4A74-AAD5-684C0E0DCBC0",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl180_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B3E4F18F-55E2-4829-A1EF-881D06CC5481",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl20_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "31223B01-2107-479B-AC77-1C31BBE2F96C",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl320e_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "51593FEE-B2A5-4642-8A3B-F0A7D85475AA",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl320e_gen8_v2_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "ED8AE8A0-82CF-47E9-99F7-FFF1EF632C90",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl360_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "34A65EC0-14C7-4838-913D-8EF11144A85B",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl360e_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AFFBB73F-EAF7-47A2-BD06-FC31172E05B6",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl360p_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "47779C63-CDE4-4BE6-96BA-CBD118E027ED",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl380_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "52F6D2D0-482F-4B2F-AF78-82BC56704E8E",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl380e_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D7D81703-DB67-4650-959B-8787ED450AE3",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl380p_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6AE425FF-B87E-40D6-A85F-7740418B3A9F",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl385p_gen8_\\(amd\\):-:*:*:*:*:*:*:*",
              "matchCriteriaId": "07F1E3B5-02FF-4C46-825F-21D6ED76F6AF",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl560_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3CED1122-4927-4665-8D6B-A6C986ED6252",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl560_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F2068295-B73A-4C01-8351-C2D8B957845B",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl580_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "407DB236-65BF-4B41-9C75-4D5BC246A905",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl580_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C3EB6796-FE83-42EB-84FF-F405289EE0B1",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl60_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F4F7E5C6-201B-4268-9CA7-13BBA1E74DF0",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl80_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0CF640F8-B432-40DA-93C8-77D8351CB390",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_microserver_gen8:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0EDDEC65-E89C-47CA-9716-F4EB936ADE9A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_ml110_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD3268D0-1F66-47BA-972C-21E809DC2F2E",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_ml30_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D9E7C549-3A1B-40DE-A1FC-0BC62040E4C8",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_ml310e_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7791C8B1-D949-4AEE-8BC5-40FECA8FBC7A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_ml310e_gen8_v2_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DBA3BC52-96CB-4F52-87BC-3E6DF13BD654",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_ml350_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4BB05A81-BDF5-4D6C-B9E3-1894703F1CC3",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_ml350e_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "92436412-45F8-49EB-B02E-5405F21B42EC",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_ml350e_gen8_v2_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5F3F92AE-CE88-4C38-AC00-6B56198D57F6",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_ml350p_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FB075F0-2825-43F5-BA0A-8348A082580C",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_sl210t_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "74F537C3-16DE-4F0C-9C38-6EE9504F841F",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_sl230s_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B6795F47-30A0-4433-96FD-808AAF536F45",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_sl250s_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "533312DC-3EB0-4F15-B7A6-BFCE5CFABC6C",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_sl270s_gen8_se_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5067AA37-ED79-403B-953E-8EC4807A7067",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_sl270s_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "361590CD-06A8-4BDF-9C24-053F31468A53",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_ws460c_gen8_graphics_server_blade:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AFD07DCA-B8AF-409F-A902-AE66CB450152",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_ws460c_gen9_graphics_server_blade:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "66E10A5D-7C64-460A-9DBE-E5BCBBFDE6C9",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_xl170r_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "58AE85AC-1062-42E2-8142-9BC754D51035",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_xl190r_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "49BA2C97-7AAB-4A55-B487-522715BDC80C",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_xl220a_gen8_v2_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "056D1649-1670-465D-9E48-292B3F451521",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_xl230a_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AA80708D-3219-4D54-B167-105DDEC5B85D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_xl230b_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE433CD5-FE98-4E41-9C18-4521DA23282F",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_xl250a_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3E62FEEB-A62D-42F4-A713-4CEAFF9B158E",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_xl270d_gen9_special_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3D87F1F6-28DA-433A-B43E-D105EE2B5EBB",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_xl450_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1CEE8B85-1F21-418F-B2D3-90151F6423BF",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_xl730f_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3C838C36-FFF2-4C90-8BF1-21984D6C9C88",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_xl740f_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C4EBB97C-4A68-4276-BFF2-93D58F6F1CA2",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_xl750f_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "425FCBD4-A94B-4AE5-B002-258CE1FE97FB",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:storeeasy_1430_storage:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "206854F1-5EBD-4073-9CF3-A54D8877212C",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:storeeasy_1440_storage:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5CC48AAA-59FC-44CD-A8AB-2E0E965559EC",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:storeeasy_1450_storage:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DAFBC1A4-A348-4FE2-B84D-6324DCAF163A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:storeeasy_1530_storage:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BE21ED77-6606-46B3-9326-2C46B7EBD128",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:storeeasy_1540_storage:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "373A69DF-504E-4D4D-B646-E02958C7784F",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:storeeasy_1550_storage:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "62B623A5-3771-405E-9F5C-174C0AC6E893",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:storeeasy_1630_storage:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D8F4AB82-4BDA-4859-A847-FBCFA7A15866",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:storeeasy_1640_storage:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE943A0C-7359-4D61-9A10-4ADA92794BCA",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:storeeasy_1650_expanded_storage:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2EAFDF1D-7EA9-4FFA-B552-97F8EC5581C8",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:storeeasy_1650_storage:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A7F0EE22-6BA9-4ACD-BEE2-9F98C2E41961",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:storeeasy_1830_storage:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5235A8FE-9234-41FF-8CA1-36D3988D2756",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:storeeasy_1840_storage:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "09BA82E3-5911-43F9-82F8-79D3D3C6A1E7",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:storeeasy_1850_storage:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4F85603B-105D-4E25-973C-90A7EDAE6FF0",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:storeeasy_3830_gateway_storage:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "43ED3B2D-74D6-4EB5-85B8-6725FBA3D461",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:storeeasy_3830_gateway_storage_blade:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C86C2B99-9DF0-4982-888C-57C8B3BEAEDA",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:storeeasy_3840_gateway_storage:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "325C2A58-86B6-4F21-B7F2-72DE964AB612",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:storeeasy_3840_gateway_storage_blade:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F939EF20-915C-4ADB-B6F8-62746ED2273D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:storeeasy_3850_gateway_single_node_upgrade:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "170E15DB-9227-4323-891F-A914B6061F49",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:storeeasy_3850_gateway_storage:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D4623E31-E486-4303-9407-DD9680DFF09C",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:storeeasy_3850_gateway_storage_blade:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F10D2BEE-E5CB-45B6-A836-849272070DCC",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:storevirtual_3000_file_controller:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BF7B8B24-E11A-4CC0-A2F3-D467BA58A6E9",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:synergy_480_gen9_compute_module:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "29BE9486-493D-495E-8CFA-1E79FE57457C",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:synergy_620_gen9_compute_module:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "789F7158-51DE-4344-BD8A-1249BFE0158B",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:synergy_660_gen9_compute_module:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0163D6F2-5E24-4741-BEF3-7B671A10CA08",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:synergy_680_gen9_compute_module:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9CBAD3B0-D47D-4E05-96D1-28A989E118CD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_5:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7A9239CA-2FC4-456E-B1FD-5A5B174A1EB5",
              "versionEndExcluding": "2.78",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hpe:apollo_4200_gen10_plus_system:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1BF55930-EC9C-4C0D-8092-3E1091902D4B",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:apollo_4200_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CFB818A6-80D5-4DD7-8E0D-EC25764A0693",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:apollo_4510_gen10_system:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "25418088-0890-401E-837C-611154B2C433",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:apollo_6500_gen10_plus_system:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D1480B92-9A59-4675-B2DF-6DAE385927B2",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:apollo_6500_gen10_system:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC09C72C-0BD3-4DB1-96C6-72F2330D4165",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:apollo_n2600_gen10_plus:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB23B5E3-887B-41C8-B83E-0203BEC9DDB1",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:apollo_n2800_gen10_plus:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "33A5C2F7-66E1-483F-95E7-D51C6D32E7CA",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:apollo_r2200_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F3FF527B-51BF-445B-80D0-42FD50D6F60A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:apollo_r2600_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7A478D98-EE4E-45ED-A257-F154693E6FB2",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:apollo_r2800_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3CAC257C-8594-454D-BA28-5D98F03AF3EC",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:edgeline_e920_server_blade:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4CB4D5F2-2E5C-4191-ACA0-D086E08FFDA4",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:edgeline_e920d_server_blade:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4AC36ED1-D392-4DC6-B3E0-99A821705AA2",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:edgeline_e920t_server_blade:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4D0ACC75-47E9-439A-9338-170478FB326F",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_bl460c_gen10_server_blade:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C25FD273-0E16-4975-985C-8BD96AE0D449",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl120_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5876FB45-B037-4355-BAE9-69157FD0A402",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl160_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F0C77CAF-0A18-4447-93BD-C64595475E37",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl180_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "08D81BA5-E5D8-4D42-8C42-A91063008359",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl20_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EA978EC2-6027-4605-BECC-68B4682DB5E5",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl20_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B15D52EA-CE63-47AF-993D-265163B5B38E",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl325_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B1F98CB6-3933-4425-A7E9-542AB764C8C4",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl325_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "93765BE7-D8C2-48C8-9ADA-A7C36B993D95",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl345_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9BE801CF-95AB-409A-8063-9525FC1A3BF1",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl360_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A540039-4339-44CE-92AD-83B80928FC81",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl360_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FD08B95A-240C-436E-91B5-2D594F6F1F07",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl365_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B7151CE9-BAD2-47B8-9283-5BEB53C93D98",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl380_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E27B2E8E-1F1D-4397-BE33-80755D6BE56C",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl380_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8545248A-2943-4B8D-A295-BE7D43492BC9",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl385_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "00B032E4-9663-4525-ACC4-217B5E266124",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl385_gen10_plus_v2_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "61758FDD-0744-4207-950E-D11717E9E5D1",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl385_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D3845235-CAFC-4FB3-AB26-F0E8A8815F88",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl560_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B8389F7F-7653-4695-91CC-DCFACC870094",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl580_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "419470B4-80EF-46BF-8DB4-6569D3E8435F",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dx170r_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7591DA99-B0CA-4A23-A8C5-C6D9084C2329",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dx190r_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A1642BAB-2EC5-4E89-86DE-7B9BECA4F6CB",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dx220n_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1D176EE5-FDE7-475B-802A-AFD21A9F6E87",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dx325_gen10_plus_v2_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "18B76D60-5493-4959-A85E-91C1D810365F",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dx360_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "40D9CF07-D08E-4B36-B25D-1011AF0463DA",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dx360_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "26D8AA54-634D-4870-AC5E-BD8F70EDB83D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dx380_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8464FB6E-5744-44B7-BD1F-87D8F382A30B",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dx380_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F2C8768C-5E7D-4C11-8C49-182CC1D643B0",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dx385_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "594B767B-41AB-436A-AF2C-10185E1161F4",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dx385_gen10_plus_v2_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "779A6A62-4357-46FF-9BA8-F53E657A4E31",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dx4200_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B00D29DB-B073-4C5A-934D-87A311D57657",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dx560_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5869DE25-F914-48E0-8AFF-72C463E99084",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_e910_server_blade:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "174EF59C-18A6-4490-A23A-76E74C1D2AFA",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_e910t_server_blade:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C755817B-B074-4496-934B-A30C72A4F849",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_ml110_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DB32875E-11E3-443E-809C-12CCAE574570",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_ml30_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5527AD20-7E19-4987-915D-FCFFEBFDA4C6",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_ml350_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C7DE16BA-939E-4C26-B03B-439E60C7C872",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_xl170r_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B224273-2E15-41F2-84D6-D754F6B76B49",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_xl190r_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1ACD7139-05F6-4D60-BB0F-9AA6952720CA",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_xl220n_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "01181BEB-DE0B-49AA-B632-91B40046120F",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_xl225n_gen10_plus_1u_node:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9334B70C-EBBD-4D0F-A0DC-EC84E014701E",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_xl230k_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "50247A44-3EA0-4B4B-9AB6-64D9B470F190",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_xl270d_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1A21F0B8-D613-46CD-BAEC-5CD876FD5352",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_xl290n_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4435D5C3-A7CB-4EA6-87A9-6026DAC8DA47",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_xl450_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DBD81201-ECD9-4E9F-A6F0-7EAEB1DA9891",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_xl645d_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "424298C0-01E2-4770-818D-25F47A801F88",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_xl675d_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1E7408A4-7409-4223-ABA7-C1F35E84D213",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:storage_file_controller:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EBCBE981-8F98-49B2-B09D-B0187D5DF322",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:storage_performance_file_controller:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1A9E7335-3545-4F2D-A915-AB6B34EBB76D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:storeeasy_1460_storage:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BFC69BAD-3243-405F-839E-8BE9E2562205",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:storeeasy_1560_storage:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C386FE40-4223-4F35-A04A-84008B7A1B8E",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:storeeasy_1660_expanded_storage:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A3E86E62-1B51-4934-B8B6-40D920BE6192",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:storeeasy_1660_performance_storage:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F5D34B52-2803-43B0-942A-F974CBE14531",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:storeeasy_1660_storage:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EFC53F93-901B-40A9-BAAD-DD5A8865E824",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:storeeasy_1860_performance_storage:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E3A06978-A8B5-4251-955F-2DF206962605",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:storeeasy_1860_storage:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D82CC8E6-A017-406E-B993-4CFFEB230829",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:synergy_480_gen10_compute_module:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "853AF641-B81C-4FB7-89AB-EACF420F0C62",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:synergy_480_gen10_plus_compute_module:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8F15301B-B695-4DC8-9EE5-517AC2E64778",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:synergy_660_gen10_compute_module:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "19188281-533B-450E-84F1-089F3300D08E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_6:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E81519FB-34FB-4FAC-B068-F821A18E4AA7",
              "versionEndExcluding": "1.20",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl320_gen11_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4D01E2C9-76B7-4C23-A9B4-7BFB90F7F848",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl325_gen11_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B8A4A0C-A33A-48E5-8F53-807A20333DE9",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl345_gen11_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "37DFB5BE-E36B-4D5D-AC60-267799B6AEF9",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl360_gen11_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE19E0B8-B23C-41E0-82DA-BEFBCDC7954A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl365_gen11_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C8E5A73F-96A5-4488-8DAE-3ECBEAD71CE9",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl380_gen11_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "05AF31FE-6C42-4D64-A216-7FD5383D50F5",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl385_gen11_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "36449636-2501-4608-968D-9E73090A4D43",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_ml350_gen11_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7A24D0AE-55B8-438A-B956-3A20F34382F2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A remote Cross-site Scripting vulnerability was discovered in HPE Integrated Lights-Out 6 (iLO 6), Integrated Lights-Out 5 (iLO 5) and Integrated Lights-Out 4 (iLO 4). HPE has provided software updates to resolve this vulnerability in HPE Integrated Lights-Out."
    }
  ],
  "id": "CVE-2023-28083",
  "lastModified": "2024-11-21T07:54:22.000",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "LOW",
          "baseScore": 8.3,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:L",
          "version": "3.1"
        },
        "exploitabilityScore": 1.7,
        "impactScore": 6.0,
        "source": "security-alert@hpe.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 5.4,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "LOW",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.3,
        "impactScore": 2.7,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-03-22T06:15:10.950",
  "references": [
    {
      "source": "security-alert@hpe.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US\u0026docId=hpesbhf04456en_us"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US\u0026docId=hpesbhf04456en_us"
    }
  ],
  "sourceIdentifier": "security-alert@hpe.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ],
      "source": "security-alert@hpe.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-05-25 15:15
Modified
2024-11-21 06:00
Summary
A remote dom xss, crlf injection vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_4:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4E25CDBB-3C9D-4AAB-BA21-0346546AA369",
              "versionEndExcluding": "2.78",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F05331F2-DF6B-4CD3-9BA4-B97A34746509",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_5:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD145EB4-A7F3-4A6D-A782-080507068D45",
              "versionEndExcluding": "2.44",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:proliant_bl460c_gen10_server_blade:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "03E00679-A2A7-4A51-9764-462BF479F423",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl120_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B553E44A-A209-49CA-A914-CC1FE51D90D8",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl160_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "666AAAE5-83AB-4018-891D-2FC69AE6AD65",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl180_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5DD32E61-4FFE-4ECF-9582-B96D1513C706",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl20_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3BDF28CD-B01A-4C31-B62A-0472AD96D255",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl325_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB5F7BC4-EAA0-47EB-A66A-B5BC60620E1F",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl325_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "58196CA6-BA67-4361-8056-B52B1A323E5D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl360_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F5FC76C8-44FC-4BCC-95C1-0717126BBE2A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl380_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BFD8AB8C-D5BA-4312-9E7A-48ECB09F3C16",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl385_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CBF5E039-BBBF-42A4-8F57-CB2B7E65D763",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl385_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "306B6EC0-C471-48B6-858C-93A4A6CB976D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl560_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6A16D30B-D064-4EEC-9628-7B64B63CE2CA",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl580_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A367F8FE-8500-4512-831A-408BB0772586",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml110_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "358CD445-B506-4EE9-A282-76A790EA4583",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml30_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D857745-3DBE-4B0A-ACE3-0159EB3D0121",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml350_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9DB2958-DDCD-4ACA-B9C1-F7914622E36B",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl170r_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F8A0F022-C271-4DB6-A12E-1A2357C0BFE9",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl190r_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "29DEE638-BD6B-4B70-ABEE-AFD8FDA99F45",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl230k_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C7B1F484-2258-4326-AEFA-725BD8EFE6CD",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl270d_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "00D87480-CB71-4BB0-A034-41B3AA9F10A4",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl450_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "81B8CA7A-F115-4932-A932-F61180E79A72",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_2600:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2A13A066-1BC1-43D3-BBCC-499F1C1C864A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_325:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE4D8959-5623-4211-BE1B-80E6557D61F2",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFA60F7D-DD77-4DED-B13B-C59025FCF3A2",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10_g:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C077CA8B-F758-4D35-BFBA-9350586BBB91",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10_h:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D2DAFA4-2B9B-455D-9ABD-28D3E36859F0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A remote dom xss, crlf injection vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
    },
    {
      "lang": "es",
      "value": "Se detect\u00f3 una vulnerabilidad de un xss dom y una inyecci\u00f3n remota de crlf en HPE Integrated Lights-Out 4 (iLO 4);\u0026#xa0;HPE SimpliVity 380 Gen9;\u0026#xa0;HPE Integrated Lights-Out 5 (iLO 5) para servidores HPE Gen10;\u0026#xa0;HPE SimpliVity 380 Gen10;\u0026#xa0;HPE SimpliVity 2600;\u0026#xa0;HPE SimpliVity 380 Gen10 G;\u0026#xa0;HPE SimpliVity 325;\u0026#xa0;Versiones de HPE SimpliVity 380 Gen10 H: anterior a versi\u00f3n 2.78"
    }
  ],
  "id": "CVE-2021-29210",
  "lastModified": "2024-11-21T06:00:49.947",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "LOW",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "NONE",
          "baseScore": 3.5,
          "confidentialityImpact": "NONE",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 6.8,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 4.8,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "HIGH",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.7,
        "impactScore": 2.7,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-05-25T15:15:07.470",
  "references": [
    {
      "source": "security-alert@hpe.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
    }
  ],
  "sourceIdentifier": "security-alert@hpe.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-74"
        },
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-05-25 15:15
Modified
2024-11-21 06:00
Summary
A remote dom xss, crlf injection vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_4:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4E25CDBB-3C9D-4AAB-BA21-0346546AA369",
              "versionEndExcluding": "2.78",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F05331F2-DF6B-4CD3-9BA4-B97A34746509",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_5:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD145EB4-A7F3-4A6D-A782-080507068D45",
              "versionEndExcluding": "2.44",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:proliant_bl460c_gen10_server_blade:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "03E00679-A2A7-4A51-9764-462BF479F423",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl120_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B553E44A-A209-49CA-A914-CC1FE51D90D8",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl160_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "666AAAE5-83AB-4018-891D-2FC69AE6AD65",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl180_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5DD32E61-4FFE-4ECF-9582-B96D1513C706",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl20_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3BDF28CD-B01A-4C31-B62A-0472AD96D255",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl325_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB5F7BC4-EAA0-47EB-A66A-B5BC60620E1F",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl325_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "58196CA6-BA67-4361-8056-B52B1A323E5D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl360_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F5FC76C8-44FC-4BCC-95C1-0717126BBE2A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl380_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BFD8AB8C-D5BA-4312-9E7A-48ECB09F3C16",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl385_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CBF5E039-BBBF-42A4-8F57-CB2B7E65D763",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl385_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "306B6EC0-C471-48B6-858C-93A4A6CB976D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl560_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6A16D30B-D064-4EEC-9628-7B64B63CE2CA",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl580_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A367F8FE-8500-4512-831A-408BB0772586",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml110_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "358CD445-B506-4EE9-A282-76A790EA4583",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml30_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D857745-3DBE-4B0A-ACE3-0159EB3D0121",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml350_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9DB2958-DDCD-4ACA-B9C1-F7914622E36B",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl170r_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F8A0F022-C271-4DB6-A12E-1A2357C0BFE9",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl190r_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "29DEE638-BD6B-4B70-ABEE-AFD8FDA99F45",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl230k_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C7B1F484-2258-4326-AEFA-725BD8EFE6CD",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl270d_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "00D87480-CB71-4BB0-A034-41B3AA9F10A4",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl450_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "81B8CA7A-F115-4932-A932-F61180E79A72",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_2600:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2A13A066-1BC1-43D3-BBCC-499F1C1C864A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_325:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE4D8959-5623-4211-BE1B-80E6557D61F2",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFA60F7D-DD77-4DED-B13B-C59025FCF3A2",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10_g:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C077CA8B-F758-4D35-BFBA-9350586BBB91",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10_h:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D2DAFA4-2B9B-455D-9ABD-28D3E36859F0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A remote dom xss, crlf injection vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
    },
    {
      "lang": "es",
      "value": "Se detect\u00f3 una vulnerabilidad de un xss dom y una inyecci\u00f3n remota de crlf en HPE Integrated Lights-Out 4 (iLO 4);\u0026#xa0;HPE SimpliVity 380 Gen9;\u0026#xa0;HPE Integrated Lights-Out 5 (iLO 5) para servidores HPE Gen10;\u0026#xa0;HPE SimpliVity 380 Gen10;\u0026#xa0;HPE SimpliVity 2600;\u0026#xa0;HPE SimpliVity 380 Gen10 G;\u0026#xa0;HPE SimpliVity 325;\u0026#xa0;Versiones de HPE SimpliVity 380 Gen10 H: anterior a versi\u00f3n 2.78"
    }
  ],
  "id": "CVE-2021-29208",
  "lastModified": "2024-11-21T06:00:49.683",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "LOW",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "NONE",
          "baseScore": 3.5,
          "confidentialityImpact": "NONE",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 6.8,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 4.8,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "HIGH",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.7,
        "impactScore": 2.7,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-05-25T15:15:07.417",
  "references": [
    {
      "source": "security-alert@hpe.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
    }
  ],
  "sourceIdentifier": "security-alert@hpe.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-74"
        },
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-05-25 14:15
Modified
2024-11-21 06:00
Summary
A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_4:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4E25CDBB-3C9D-4AAB-BA21-0346546AA369",
              "versionEndExcluding": "2.78",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F05331F2-DF6B-4CD3-9BA4-B97A34746509",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_5:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD145EB4-A7F3-4A6D-A782-080507068D45",
              "versionEndExcluding": "2.44",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:proliant_bl460c_gen10_server_blade:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "03E00679-A2A7-4A51-9764-462BF479F423",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl120_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B553E44A-A209-49CA-A914-CC1FE51D90D8",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl160_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "666AAAE5-83AB-4018-891D-2FC69AE6AD65",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl180_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5DD32E61-4FFE-4ECF-9582-B96D1513C706",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl20_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3BDF28CD-B01A-4C31-B62A-0472AD96D255",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl325_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB5F7BC4-EAA0-47EB-A66A-B5BC60620E1F",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl325_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "58196CA6-BA67-4361-8056-B52B1A323E5D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl360_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F5FC76C8-44FC-4BCC-95C1-0717126BBE2A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl380_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BFD8AB8C-D5BA-4312-9E7A-48ECB09F3C16",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl385_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CBF5E039-BBBF-42A4-8F57-CB2B7E65D763",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl385_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "306B6EC0-C471-48B6-858C-93A4A6CB976D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl560_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6A16D30B-D064-4EEC-9628-7B64B63CE2CA",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl580_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A367F8FE-8500-4512-831A-408BB0772586",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml110_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "358CD445-B506-4EE9-A282-76A790EA4583",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml30_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D857745-3DBE-4B0A-ACE3-0159EB3D0121",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml350_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9DB2958-DDCD-4ACA-B9C1-F7914622E36B",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl170r_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F8A0F022-C271-4DB6-A12E-1A2357C0BFE9",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl190r_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "29DEE638-BD6B-4B70-ABEE-AFD8FDA99F45",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl230k_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C7B1F484-2258-4326-AEFA-725BD8EFE6CD",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl270d_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "00D87480-CB71-4BB0-A034-41B3AA9F10A4",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl450_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "81B8CA7A-F115-4932-A932-F61180E79A72",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_2600:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2A13A066-1BC1-43D3-BBCC-499F1C1C864A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_325:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE4D8959-5623-4211-BE1B-80E6557D61F2",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFA60F7D-DD77-4DED-B13B-C59025FCF3A2",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10_g:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C077CA8B-F758-4D35-BFBA-9350586BBB91",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10_h:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D2DAFA4-2B9B-455D-9ABD-28D3E36859F0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
    },
    {
      "lang": "es",
      "value": "Se detect\u00f3 una vulnerabilidad  de tipo XSS remota en HPE Integrated Lights-Out 4 (iLO 4);\u0026#xa0;HPE SimpliVity 380 Gen9;\u0026#xa0;HPE Integrated Lights-Out 5 (iLO 5) para servidores HPE Gen10;\u0026#xa0;HPE SimpliVity 380 Gen10;\u0026#xa0;HPE SimpliVity 2600;\u0026#xa0;HPE SimpliVity 380 Gen10 G;\u0026#xa0;HPE SimpliVity 325;\u0026#xa0;Versiones de HPE SimpliVity 380 Gen10 H: anterior a versi\u00f3n 2.78"
    }
  ],
  "id": "CVE-2021-29207",
  "lastModified": "2024-11-21T06:00:49.557",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "LOW",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "NONE",
          "baseScore": 3.5,
          "confidentialityImpact": "NONE",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 6.8,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 4.8,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "HIGH",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.7,
        "impactScore": 2.7,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-05-25T14:15:07.730",
  "references": [
    {
      "source": "security-alert@hpe.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
    }
  ],
  "sourceIdentifier": "security-alert@hpe.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-05-09 21:15
Modified
2024-11-21 06:49
Summary
A potential security vulnerability has been identified in Integrated Lights-Out 4 (iLO 4). The vulnerability could allow remote Denial of Service. The vulnerability is resolved in Integrated Lights-Out 4 (iLO 4) 2.80 and later.
Impacted products
Vendor Product Version
hp integrated_lights-out_4 *
hpe apollo_4200_gen9_server -
hpe proliant_bl420c_gen8_server -
hpe proliant_bl460c_gen8_server_blade -
hpe proliant_bl460c_gen9_server_blade -
hpe proliant_bl465c_gen8_server_blade -
hpe proliant_bl660c_gen8_server_blade -
hpe proliant_bl660c_gen9_server -
hpe proliant_dl120_gen9_server -
hpe proliant_dl160_gen8_server -
hpe proliant_dl160_gen9_server -
hpe proliant_dl180_gen9_server -
hpe proliant_dl20_gen9_server -
hpe proliant_dl320e_gen8_server -
hpe proliant_dl320e_gen8_v2_server -
hpe proliant_dl360_gen9_server -
hpe proliant_dl360e_gen8_server -
hpe proliant_dl360p_gen8_server -
hpe proliant_dl380_gen9_server -
hpe proliant_dl380e_gen8_server -
hpe proliant_dl380p_gen8_server -
hpe proliant_dl385p_gen8 -
hpe proliant_dl560_gen8_server -
hpe proliant_dl560_gen9_server -
hpe proliant_dl580_gen8_server -
hpe proliant_dl580_gen9_server -
hpe proliant_dl60_gen9_server -
hpe proliant_dl80_gen9_server -
hpe proliant_ec200a_server -
hpe proliant_microserver_gen8 -
hpe proliant_ml110_gen9_server -
hpe proliant_ml150_gen9_server -
hpe proliant_ml30_gen9_server -
hpe proliant_ml310e_gen8_server -
hpe proliant_ml310e_gen8_v2_server -
hpe proliant_ml350_gen9_server -
hpe proliant_ml350e_gen8_v2_server -
hpe proliant_ml350p_gen8_server -
hpe proliant_sl210t_gen8_server -
hpe proliant_sl230s_gen8_server -
hpe proliant_sl250s_gen8_server -
hpe proliant_sl270s_gen8_se_server -
hpe proliant_sl270s_gen8_server -
hpe proliant_sl4540_gen8_1_node_server -
hpe proliant_ws460c_gen8_graphics_server_blade -
hpe proliant_ws460c_gen9_graphics_server_blade -
hpe proliant_xl170r_gen9_server -
hpe proliant_xl190r_gen9_server -
hpe proliant_xl220a_gen8_v2_server -
hpe proliant_xl230a_gen9_server -
hpe proliant_xl250a_gen9_server -
hpe proliant_xl450_gen9_server -
hpe proliant_xl730f_gen9_server -
hpe proliant_xl740f_gen9_server -
hpe proliant_xl750f_gen9_server -
hpe synergy_480_gen9_compute_module -
hpe synergy_620_gen9_compute_module -
hpe synergy_660_gen9_compute_module -
hpe synergy_680_gen9_compute_module -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_4:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DB97149F-4E5A-4E25-9FEC-5E1610E714A1",
              "versionEndExcluding": "2.80",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hpe:apollo_4200_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C20D38E9-B2EA-4ECC-B9EC-D29BB249AC77",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_bl420c_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2E3C760C-2DAF-45CE-972B-B86D963B16BC",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_bl460c_gen8_server_blade:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B110E689-1823-42D6-91E6-81115A2CB048",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_bl460c_gen9_server_blade:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D230E7A-D852-4040-83CF-164AA3233F00",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_bl465c_gen8_server_blade:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1C786E99-CDC8-4265-A05B-931602A4E10B",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_bl660c_gen8_server_blade:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "91276F1E-6475-479D-857C-689E210116B8",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_bl660c_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E2E685C0-E20A-4E95-A76F-8D18AF92C0F4",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl120_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C6B65F98-15A8-48FA-A836-97430AF183EB",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl160_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "346996C3-E131-4BE0-9261-E32D0567F795",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl160_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E1AD90B1-F95C-4A74-AAD5-684C0E0DCBC0",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl180_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B3E4F18F-55E2-4829-A1EF-881D06CC5481",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl20_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "31223B01-2107-479B-AC77-1C31BBE2F96C",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl320e_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "51593FEE-B2A5-4642-8A3B-F0A7D85475AA",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl320e_gen8_v2_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "ED8AE8A0-82CF-47E9-99F7-FFF1EF632C90",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl360_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "34A65EC0-14C7-4838-913D-8EF11144A85B",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl360e_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AFFBB73F-EAF7-47A2-BD06-FC31172E05B6",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl360p_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "47779C63-CDE4-4BE6-96BA-CBD118E027ED",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl380_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "52F6D2D0-482F-4B2F-AF78-82BC56704E8E",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl380e_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D7D81703-DB67-4650-959B-8787ED450AE3",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl380p_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6AE425FF-B87E-40D6-A85F-7740418B3A9F",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl385p_gen8:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DD391773-8FB9-429A-84B3-7DC084AFFD8B",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl560_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3CED1122-4927-4665-8D6B-A6C986ED6252",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl560_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F2068295-B73A-4C01-8351-C2D8B957845B",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl580_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "407DB236-65BF-4B41-9C75-4D5BC246A905",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl580_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C3EB6796-FE83-42EB-84FF-F405289EE0B1",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl60_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F4F7E5C6-201B-4268-9CA7-13BBA1E74DF0",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_dl80_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0CF640F8-B432-40DA-93C8-77D8351CB390",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_ec200a_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7A450C2D-76BE-4192-A913-0B46EC7EA51D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_microserver_gen8:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0EDDEC65-E89C-47CA-9716-F4EB936ADE9A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_ml110_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD3268D0-1F66-47BA-972C-21E809DC2F2E",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_ml150_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2703B986-0709-4D89-8CAF-7C3FB63D7D3F",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_ml30_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D9E7C549-3A1B-40DE-A1FC-0BC62040E4C8",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_ml310e_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7791C8B1-D949-4AEE-8BC5-40FECA8FBC7A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_ml310e_gen8_v2_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DBA3BC52-96CB-4F52-87BC-3E6DF13BD654",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_ml350_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4BB05A81-BDF5-4D6C-B9E3-1894703F1CC3",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_ml350e_gen8_v2_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5F3F92AE-CE88-4C38-AC00-6B56198D57F6",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_ml350p_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FB075F0-2825-43F5-BA0A-8348A082580C",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_sl210t_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "74F537C3-16DE-4F0C-9C38-6EE9504F841F",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_sl230s_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B6795F47-30A0-4433-96FD-808AAF536F45",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_sl250s_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "533312DC-3EB0-4F15-B7A6-BFCE5CFABC6C",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_sl270s_gen8_se_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5067AA37-ED79-403B-953E-8EC4807A7067",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_sl270s_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "361590CD-06A8-4BDF-9C24-053F31468A53",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_sl4540_gen8_1_node_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B8687283-2061-4D3C-99E5-CB920347413A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_ws460c_gen8_graphics_server_blade:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AFD07DCA-B8AF-409F-A902-AE66CB450152",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_ws460c_gen9_graphics_server_blade:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "66E10A5D-7C64-460A-9DBE-E5BCBBFDE6C9",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_xl170r_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "58AE85AC-1062-42E2-8142-9BC754D51035",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_xl190r_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "49BA2C97-7AAB-4A55-B487-522715BDC80C",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_xl220a_gen8_v2_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "056D1649-1670-465D-9E48-292B3F451521",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_xl230a_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AA80708D-3219-4D54-B167-105DDEC5B85D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_xl250a_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3E62FEEB-A62D-42F4-A713-4CEAFF9B158E",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_xl450_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1CEE8B85-1F21-418F-B2D3-90151F6423BF",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_xl730f_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3C838C36-FFF2-4C90-8BF1-21984D6C9C88",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_xl740f_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C4EBB97C-4A68-4276-BFF2-93D58F6F1CA2",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:proliant_xl750f_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "425FCBD4-A94B-4AE5-B002-258CE1FE97FB",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:synergy_480_gen9_compute_module:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "29BE9486-493D-495E-8CFA-1E79FE57457C",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:synergy_620_gen9_compute_module:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "789F7158-51DE-4344-BD8A-1249BFE0158B",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:synergy_660_gen9_compute_module:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0163D6F2-5E24-4741-BEF3-7B671A10CA08",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hpe:synergy_680_gen9_compute_module:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9CBAD3B0-D47D-4E05-96D1-28A989E118CD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A potential security vulnerability has been identified in Integrated Lights-Out 4 (iLO 4). The vulnerability could allow remote Denial of Service. The vulnerability is resolved in Integrated Lights-Out 4 (iLO 4) 2.80 and later."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una posible vulnerabilidad de seguridad en Integrated Lights-Out 4 (iLO 4). La vulnerabilidad podr\u00eda permitir una Denegaci\u00f3n de Servicio remota. La vulnerabilidad ha sido resuelta en Integrated Lights-Out 4 (iLO 4) versiones 2.80 y posteriores"
    }
  ],
  "id": "CVE-2022-23704",
  "lastModified": "2024-11-21T06:49:08.550",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 5.0,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-05-09T21:15:08.047",
  "references": [
    {
      "source": "security-alert@hpe.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04240en_us"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04240en_us"
    }
  ],
  "sourceIdentifier": "security-alert@hpe.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2018-02-15 22:29
Modified
2024-11-21 03:09
Severity ?
Summary
A authentication bypass and execution of code vulnerability in HPE Integrated Lights-out 4 (iLO 4) version prior to 2.53 was found.
Impacted products



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B004A3E9-7318-4AD3-B808-0F0E3BE12799",
              "versionEndExcluding": "2.53",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:integrated_lights-out_4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "47EEB8DA-1CDD-428C-988C-249E2816F18C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A authentication bypass and execution of code vulnerability in HPE Integrated Lights-out 4 (iLO 4) version prior to 2.53 was found."
    },
    {
      "lang": "es",
      "value": "Se ha encontrado una vulnerabilidad de omisi\u00f3n de autenticaci\u00f3n y ejecuci\u00f3n de c\u00f3digo en HPE Integrated Lights-out 4 (iLO 4) en versiones anteriores a la 2.53."
    }
  ],
  "id": "CVE-2017-12542",
  "lastModified": "2024-11-21T03:09:43.333",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 10.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 10.0,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 6.0,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2018-02-15T22:29:04.263",
  "references": [
    {
      "source": "security-alert@hpe.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/100467"
    },
    {
      "source": "security-alert@hpe.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securitytracker.com/id/1039222"
    },
    {
      "source": "security-alert@hpe.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-hpesbhf03769en_us"
    },
    {
      "source": "security-alert@hpe.com",
      "tags": [
        "Exploit",
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.exploit-db.com/exploits/44005/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/100467"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securitytracker.com/id/1039222"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-hpesbhf03769en_us"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.exploit-db.com/exploits/44005/"
    }
  ],
  "sourceIdentifier": "security-alert@hpe.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-05-25 14:15
Modified
2024-11-21 06:00
Summary
A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_4:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4E25CDBB-3C9D-4AAB-BA21-0346546AA369",
              "versionEndExcluding": "2.78",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F05331F2-DF6B-4CD3-9BA4-B97A34746509",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_5:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD145EB4-A7F3-4A6D-A782-080507068D45",
              "versionEndExcluding": "2.44",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:proliant_bl460c_gen10_server_blade:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "03E00679-A2A7-4A51-9764-462BF479F423",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl120_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B553E44A-A209-49CA-A914-CC1FE51D90D8",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl160_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "666AAAE5-83AB-4018-891D-2FC69AE6AD65",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl180_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5DD32E61-4FFE-4ECF-9582-B96D1513C706",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl20_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3BDF28CD-B01A-4C31-B62A-0472AD96D255",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl325_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB5F7BC4-EAA0-47EB-A66A-B5BC60620E1F",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl325_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "58196CA6-BA67-4361-8056-B52B1A323E5D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl360_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F5FC76C8-44FC-4BCC-95C1-0717126BBE2A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl380_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BFD8AB8C-D5BA-4312-9E7A-48ECB09F3C16",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl385_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CBF5E039-BBBF-42A4-8F57-CB2B7E65D763",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl385_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "306B6EC0-C471-48B6-858C-93A4A6CB976D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl560_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6A16D30B-D064-4EEC-9628-7B64B63CE2CA",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl580_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A367F8FE-8500-4512-831A-408BB0772586",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml110_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "358CD445-B506-4EE9-A282-76A790EA4583",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml30_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D857745-3DBE-4B0A-ACE3-0159EB3D0121",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml350_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9DB2958-DDCD-4ACA-B9C1-F7914622E36B",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl170r_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F8A0F022-C271-4DB6-A12E-1A2357C0BFE9",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl190r_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "29DEE638-BD6B-4B70-ABEE-AFD8FDA99F45",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl230k_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C7B1F484-2258-4326-AEFA-725BD8EFE6CD",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl270d_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "00D87480-CB71-4BB0-A034-41B3AA9F10A4",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl450_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "81B8CA7A-F115-4932-A932-F61180E79A72",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_2600:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2A13A066-1BC1-43D3-BBCC-499F1C1C864A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_325:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE4D8959-5623-4211-BE1B-80E6557D61F2",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFA60F7D-DD77-4DED-B13B-C59025FCF3A2",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10_g:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C077CA8B-F758-4D35-BFBA-9350586BBB91",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10_h:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D2DAFA4-2B9B-455D-9ABD-28D3E36859F0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
    },
    {
      "lang": "es",
      "value": "Se detect\u00f3 una vulnerabilidad  de tipo XSS remota en HPE Integrated Lights-Out 4 (iLO 4);\u0026#xa0;HPE SimpliVity 380 Gen9;\u0026#xa0;HPE Integrated Lights-Out 5 (iLO 5) para servidores HPE Gen10;\u0026#xa0;HPE SimpliVity 380 Gen10;\u0026#xa0;HPE SimpliVity 2600;\u0026#xa0;HPE SimpliVity 380 Gen10 G;\u0026#xa0;HPE SimpliVity 325;\u0026#xa0;Versiones de HPE SimpliVity 380 Gen10 H: anterior a versi\u00f3n 2.78"
    }
  ],
  "id": "CVE-2021-29204",
  "lastModified": "2024-11-21T06:00:49.170",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "LOW",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "NONE",
          "baseScore": 3.5,
          "confidentialityImpact": "NONE",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 6.8,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 4.8,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "HIGH",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.7,
        "impactScore": 2.7,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-05-25T14:15:07.637",
  "references": [
    {
      "source": "security-alert@hpe.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
    }
  ],
  "sourceIdentifier": "security-alert@hpe.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-05-25 14:15
Modified
2024-11-21 06:00
Summary
A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_4:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4E25CDBB-3C9D-4AAB-BA21-0346546AA369",
              "versionEndExcluding": "2.78",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F05331F2-DF6B-4CD3-9BA4-B97A34746509",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_5:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD145EB4-A7F3-4A6D-A782-080507068D45",
              "versionEndExcluding": "2.44",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:proliant_bl460c_gen10_server_blade:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "03E00679-A2A7-4A51-9764-462BF479F423",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl120_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B553E44A-A209-49CA-A914-CC1FE51D90D8",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl160_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "666AAAE5-83AB-4018-891D-2FC69AE6AD65",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl180_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5DD32E61-4FFE-4ECF-9582-B96D1513C706",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl20_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3BDF28CD-B01A-4C31-B62A-0472AD96D255",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl325_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB5F7BC4-EAA0-47EB-A66A-B5BC60620E1F",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl325_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "58196CA6-BA67-4361-8056-B52B1A323E5D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl360_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F5FC76C8-44FC-4BCC-95C1-0717126BBE2A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl380_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BFD8AB8C-D5BA-4312-9E7A-48ECB09F3C16",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl385_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CBF5E039-BBBF-42A4-8F57-CB2B7E65D763",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl385_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "306B6EC0-C471-48B6-858C-93A4A6CB976D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl560_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6A16D30B-D064-4EEC-9628-7B64B63CE2CA",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl580_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A367F8FE-8500-4512-831A-408BB0772586",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml110_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "358CD445-B506-4EE9-A282-76A790EA4583",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml30_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D857745-3DBE-4B0A-ACE3-0159EB3D0121",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml350_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9DB2958-DDCD-4ACA-B9C1-F7914622E36B",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl170r_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F8A0F022-C271-4DB6-A12E-1A2357C0BFE9",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl190r_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "29DEE638-BD6B-4B70-ABEE-AFD8FDA99F45",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl230k_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C7B1F484-2258-4326-AEFA-725BD8EFE6CD",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl270d_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "00D87480-CB71-4BB0-A034-41B3AA9F10A4",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl450_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "81B8CA7A-F115-4932-A932-F61180E79A72",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_2600:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2A13A066-1BC1-43D3-BBCC-499F1C1C864A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_325:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE4D8959-5623-4211-BE1B-80E6557D61F2",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFA60F7D-DD77-4DED-B13B-C59025FCF3A2",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10_g:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C077CA8B-F758-4D35-BFBA-9350586BBB91",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10_h:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D2DAFA4-2B9B-455D-9ABD-28D3E36859F0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
    },
    {
      "lang": "es",
      "value": "Se detect\u00f3 una vulnerabilidad  de tipo xss remota en HPE Integrated Lights-Out 4 (iLO 4);\u0026#xa0;HPE SimpliVity 380 Gen9;\u0026#xa0;HPE Integrated Lights-Out 5 (iLO 5) para servidores HPE Gen10;\u0026#xa0;HPE SimpliVity 380 Gen10;\u0026#xa0;HPE SimpliVity 2600;\u0026#xa0;HPE SimpliVity 380 Gen10 G;\u0026#xa0;HPE SimpliVity 325;\u0026#xa0;Versiones de HPE SimpliVity 380 Gen10 H: anterior a versi\u00f3n 2.78"
    }
  ],
  "id": "CVE-2021-29206",
  "lastModified": "2024-11-21T06:00:49.417",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "LOW",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "NONE",
          "baseScore": 3.5,
          "confidentialityImpact": "NONE",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 6.8,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 4.8,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "HIGH",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.7,
        "impactScore": 2.7,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-05-25T14:15:07.693",
  "references": [
    {
      "source": "security-alert@hpe.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
    }
  ],
  "sourceIdentifier": "security-alert@hpe.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-05-25 14:15
Modified
2024-11-21 06:00
Summary
A local buffer overflow vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_4:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4E25CDBB-3C9D-4AAB-BA21-0346546AA369",
              "versionEndExcluding": "2.78",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F05331F2-DF6B-4CD3-9BA4-B97A34746509",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_5:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD145EB4-A7F3-4A6D-A782-080507068D45",
              "versionEndExcluding": "2.44",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:proliant_bl460c_gen10_server_blade:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "03E00679-A2A7-4A51-9764-462BF479F423",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl120_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B553E44A-A209-49CA-A914-CC1FE51D90D8",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl160_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "666AAAE5-83AB-4018-891D-2FC69AE6AD65",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl180_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5DD32E61-4FFE-4ECF-9582-B96D1513C706",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl20_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3BDF28CD-B01A-4C31-B62A-0472AD96D255",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl325_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB5F7BC4-EAA0-47EB-A66A-B5BC60620E1F",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl325_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "58196CA6-BA67-4361-8056-B52B1A323E5D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl360_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F5FC76C8-44FC-4BCC-95C1-0717126BBE2A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl380_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BFD8AB8C-D5BA-4312-9E7A-48ECB09F3C16",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl385_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CBF5E039-BBBF-42A4-8F57-CB2B7E65D763",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl385_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "306B6EC0-C471-48B6-858C-93A4A6CB976D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl560_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6A16D30B-D064-4EEC-9628-7B64B63CE2CA",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl580_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A367F8FE-8500-4512-831A-408BB0772586",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml110_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "358CD445-B506-4EE9-A282-76A790EA4583",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml30_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D857745-3DBE-4B0A-ACE3-0159EB3D0121",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml350_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9DB2958-DDCD-4ACA-B9C1-F7914622E36B",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl170r_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F8A0F022-C271-4DB6-A12E-1A2357C0BFE9",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl190r_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "29DEE638-BD6B-4B70-ABEE-AFD8FDA99F45",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl230k_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C7B1F484-2258-4326-AEFA-725BD8EFE6CD",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl270d_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "00D87480-CB71-4BB0-A034-41B3AA9F10A4",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl450_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "81B8CA7A-F115-4932-A932-F61180E79A72",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_2600:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2A13A066-1BC1-43D3-BBCC-499F1C1C864A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_325:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE4D8959-5623-4211-BE1B-80E6557D61F2",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFA60F7D-DD77-4DED-B13B-C59025FCF3A2",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10_g:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C077CA8B-F758-4D35-BFBA-9350586BBB91",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10_h:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D2DAFA4-2B9B-455D-9ABD-28D3E36859F0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A local buffer overflow vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
    },
    {
      "lang": "es",
      "value": "Se detect\u00f3 una vulnerabilidad de desbordamiento del b\u00fafer local en HPE Integrated Lights-Out 4 (iLO 4);\u0026#xa0;HPE SimpliVity 380 Gen9;\u0026#xa0;HPE Integrated Lights-Out 5 (iLO 5) para servidores HPE Gen10;\u0026#xa0;HPE SimpliVity 380 Gen10;\u0026#xa0;HPE SimpliVity 2600;\u0026#xa0;HPE SimpliVity 380 Gen10 G;\u0026#xa0;HPE SimpliVity 325;\u0026#xa0;Versiones de HPE SimpliVity 380 Gen10 H: anterior a versi\u00f3n 2.78"
    }
  ],
  "id": "CVE-2021-29202",
  "lastModified": "2024-11-21T06:00:48.930",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "LOCAL",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 4.6,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 6.7,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 0.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-05-25T14:15:07.607",
  "references": [
    {
      "source": "security-alert@hpe.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
    }
  ],
  "sourceIdentifier": "security-alert@hpe.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-120"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2016-09-08 16:59
Modified
2024-11-21 02:51
Severity ?
Summary
Multiple unspecified vulnerabilities in HPE Integrated Lights-Out 3 (aka iLO 3) firmware before 1.88, Integrated Lights-Out 4 (aka iLO 4) firmware before 2.44, and Integrated Lights-Out 4 (aka iLO 4) mRCA firmware before 2.32 allow remote attackers to obtain sensitive information, modify data, or cause a denial of service via unknown vectors.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_3_firmware:1.87:*:*:*:*:*:*:*",
              "matchCriteriaId": "1E74314B-307A-4F3B-A517-F02B74B32B79",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_4_firmware:2.43:*:*:*:*:*:*:*",
              "matchCriteriaId": "0FF64F5C-BA91-4D78-927C-5359F2A5D049",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_4_mrca_firmware:2.31:*:*:*:*:*:*:*",
              "matchCriteriaId": "9B85C14E-6658-48F2-AAB7-EFA610CF2C14",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:integrated_lights-out_3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A637F287-5A65-497B-8A28-647E774CF678",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:integrated_lights-out_4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "47EEB8DA-1CDD-428C-988C-249E2816F18C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Multiple unspecified vulnerabilities in HPE Integrated Lights-Out 3 (aka iLO 3) firmware before 1.88, Integrated Lights-Out 4 (aka iLO 4) firmware before 2.44, and Integrated Lights-Out 4 (aka iLO 4) mRCA firmware before 2.32 allow remote attackers to obtain sensitive information, modify data, or cause a denial of service via unknown vectors."
    },
    {
      "lang": "es",
      "value": "M\u00faltiples vulnerabilidades no especificadas en firmware HPE Integrated Lights-Out 3 (tambi\u00e9n conocido como iLO 3) en versiones anteriores a 1.88, firmware Integrated Lights-Out 4 (tambi\u00e9n conocido como iLO 4) en versiones anteriores a 2.44 y firmware mRCA Integrated Lights-Out 4 (tambi\u00e9n conocido como iLO 4) en versiones anteriores a 2.32 permite a atacantes remotos obtener informaci\u00f3n sensible, modificar datos o provocar una denegaci\u00f3n de servicio a trav\u00e9s de vectores desconocidos."
    }
  ],
  "id": "CVE-2016-4375",
  "lastModified": "2024-11-21T02:51:58.800",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": true,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 7.5,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2016-09-08T16:59:00.143",
  "references": [
    {
      "source": "cve@mitre.org",
      "url": "http://www.securityfocus.com/bid/92484"
    },
    {
      "source": "cve@mitre.org",
      "url": "http://www.securitytracker.com/id/1036629"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://h20566.www2.hpe.com/portal/site/hpsc/public/kb/docDisplay?docId=emr_na-c05236950"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://www.securityfocus.com/bid/92484"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://www.securitytracker.com/id/1036629"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://h20566.www2.hpe.com/portal/site/hpsc/public/kb/docDisplay?docId=emr_na-c05236950"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-05-25 14:15
Modified
2024-11-21 06:00
Summary
A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_4:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4E25CDBB-3C9D-4AAB-BA21-0346546AA369",
              "versionEndExcluding": "2.78",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F05331F2-DF6B-4CD3-9BA4-B97A34746509",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_5:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD145EB4-A7F3-4A6D-A782-080507068D45",
              "versionEndExcluding": "2.44",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:proliant_bl460c_gen10_server_blade:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "03E00679-A2A7-4A51-9764-462BF479F423",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl120_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B553E44A-A209-49CA-A914-CC1FE51D90D8",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl160_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "666AAAE5-83AB-4018-891D-2FC69AE6AD65",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl180_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5DD32E61-4FFE-4ECF-9582-B96D1513C706",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl20_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3BDF28CD-B01A-4C31-B62A-0472AD96D255",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl325_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB5F7BC4-EAA0-47EB-A66A-B5BC60620E1F",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl325_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "58196CA6-BA67-4361-8056-B52B1A323E5D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl360_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F5FC76C8-44FC-4BCC-95C1-0717126BBE2A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl380_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BFD8AB8C-D5BA-4312-9E7A-48ECB09F3C16",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl385_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CBF5E039-BBBF-42A4-8F57-CB2B7E65D763",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl385_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "306B6EC0-C471-48B6-858C-93A4A6CB976D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl560_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6A16D30B-D064-4EEC-9628-7B64B63CE2CA",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl580_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A367F8FE-8500-4512-831A-408BB0772586",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml110_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "358CD445-B506-4EE9-A282-76A790EA4583",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml30_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D857745-3DBE-4B0A-ACE3-0159EB3D0121",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml350_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9DB2958-DDCD-4ACA-B9C1-F7914622E36B",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl170r_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F8A0F022-C271-4DB6-A12E-1A2357C0BFE9",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl190r_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "29DEE638-BD6B-4B70-ABEE-AFD8FDA99F45",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl230k_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C7B1F484-2258-4326-AEFA-725BD8EFE6CD",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl270d_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "00D87480-CB71-4BB0-A034-41B3AA9F10A4",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl450_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "81B8CA7A-F115-4932-A932-F61180E79A72",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_2600:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2A13A066-1BC1-43D3-BBCC-499F1C1C864A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_325:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE4D8959-5623-4211-BE1B-80E6557D61F2",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFA60F7D-DD77-4DED-B13B-C59025FCF3A2",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10_g:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C077CA8B-F758-4D35-BFBA-9350586BBB91",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10_h:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D2DAFA4-2B9B-455D-9ABD-28D3E36859F0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
    },
    {
      "lang": "es",
      "value": "Se detect\u00f3 una vulnerabilidad  de tipo XSS remota en HPE Integrated Lights-Out 4 (iLO 4);\u0026#xa0;HPE SimpliVity 380 Gen9;\u0026#xa0;HPE Integrated Lights-Out 5 (iLO 5) para servidores HPE Gen10;\u0026#xa0;HPE SimpliVity 380 Gen10;\u0026#xa0;HPE SimpliVity 2600;\u0026#xa0;HPE SimpliVity 380 Gen10 G;\u0026#xa0;HPE SimpliVity 325;\u0026#xa0;Versiones de HPE SimpliVity 380 Gen10 H: anterior a versi\u00f3n 2.78"
    }
  ],
  "id": "CVE-2021-29205",
  "lastModified": "2024-11-21T06:00:49.293",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "LOW",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "NONE",
          "baseScore": 3.5,
          "confidentialityImpact": "NONE",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 6.8,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 4.8,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "HIGH",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.7,
        "impactScore": 2.7,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-05-25T14:15:07.663",
  "references": [
    {
      "source": "security-alert@hpe.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
    }
  ],
  "sourceIdentifier": "security-alert@hpe.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-05-25 14:15
Modified
2024-11-21 06:00
Summary
A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_4:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4E25CDBB-3C9D-4AAB-BA21-0346546AA369",
              "versionEndExcluding": "2.78",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F05331F2-DF6B-4CD3-9BA4-B97A34746509",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_5:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD145EB4-A7F3-4A6D-A782-080507068D45",
              "versionEndExcluding": "2.44",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:proliant_bl460c_gen10_server_blade:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "03E00679-A2A7-4A51-9764-462BF479F423",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl120_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B553E44A-A209-49CA-A914-CC1FE51D90D8",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl160_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "666AAAE5-83AB-4018-891D-2FC69AE6AD65",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl180_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5DD32E61-4FFE-4ECF-9582-B96D1513C706",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl20_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3BDF28CD-B01A-4C31-B62A-0472AD96D255",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl325_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB5F7BC4-EAA0-47EB-A66A-B5BC60620E1F",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl325_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "58196CA6-BA67-4361-8056-B52B1A323E5D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl360_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F5FC76C8-44FC-4BCC-95C1-0717126BBE2A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl380_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BFD8AB8C-D5BA-4312-9E7A-48ECB09F3C16",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl385_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CBF5E039-BBBF-42A4-8F57-CB2B7E65D763",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl385_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "306B6EC0-C471-48B6-858C-93A4A6CB976D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl560_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6A16D30B-D064-4EEC-9628-7B64B63CE2CA",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl580_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A367F8FE-8500-4512-831A-408BB0772586",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml110_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "358CD445-B506-4EE9-A282-76A790EA4583",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml30_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D857745-3DBE-4B0A-ACE3-0159EB3D0121",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml350_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9DB2958-DDCD-4ACA-B9C1-F7914622E36B",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl170r_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F8A0F022-C271-4DB6-A12E-1A2357C0BFE9",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl190r_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "29DEE638-BD6B-4B70-ABEE-AFD8FDA99F45",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl230k_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C7B1F484-2258-4326-AEFA-725BD8EFE6CD",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl270d_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "00D87480-CB71-4BB0-A034-41B3AA9F10A4",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl450_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "81B8CA7A-F115-4932-A932-F61180E79A72",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_2600:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2A13A066-1BC1-43D3-BBCC-499F1C1C864A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_325:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE4D8959-5623-4211-BE1B-80E6557D61F2",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFA60F7D-DD77-4DED-B13B-C59025FCF3A2",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10_g:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C077CA8B-F758-4D35-BFBA-9350586BBB91",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10_h:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D2DAFA4-2B9B-455D-9ABD-28D3E36859F0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
    },
    {
      "lang": "es",
      "value": "Se detect\u00f3 una vulnerabilidad de tipo xss remota en HPE Integrated Lights-Out 4 (iLO 4);\u0026#xa0;HPE SimpliVity 380 Gen9;\u0026#xa0;HPE Integrated Lights-Out 5 (iLO 5) para servidores HPE Gen10;\u0026#xa0;HPE SimpliVity 380 Gen10;\u0026#xa0;HPE SimpliVity 2600;\u0026#xa0;HPE SimpliVity 380 Gen10 G;\u0026#xa0;HPE SimpliVity 325;\u0026#xa0;Versiones de HPE SimpliVity 380 Gen10 H: anterior a versi\u00f3n 2.78"
    }
  ],
  "id": "CVE-2021-29201",
  "lastModified": "2024-11-21T06:00:48.803",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "LOW",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "NONE",
          "baseScore": 3.5,
          "confidentialityImpact": "NONE",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 6.8,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 4.8,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "HIGH",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.7,
        "impactScore": 2.7,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-05-25T14:15:07.570",
  "references": [
    {
      "source": "security-alert@hpe.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
    }
  ],
  "sourceIdentifier": "security-alert@hpe.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

cve-2022-23704
Vulnerability from cvelistv5
Published
2022-05-09 20:17
Modified
2024-08-03 03:51
Severity ?
Summary
A potential security vulnerability has been identified in Integrated Lights-Out 4 (iLO 4). The vulnerability could allow remote Denial of Service. The vulnerability is resolved in Integrated Lights-Out 4 (iLO 4) 2.80 and later.
Impacted products
Vendor Product Version
n/a HPE Integrated Lights-Out 4 (iLO 4) Version: Prior to iLO 4 version 2.80
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T03:51:45.936Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04240en_us"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "HPE Integrated Lights-Out 4 (iLO 4)",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Prior to iLO 4 version 2.80"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A potential security vulnerability has been identified in Integrated Lights-Out 4 (iLO 4). The vulnerability could allow remote Denial of Service. The vulnerability is resolved in Integrated Lights-Out 4 (iLO 4) 2.80 and later."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "remote denial of service (DoS)",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-05-09T20:17:34",
        "orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
        "shortName": "hpe"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04240en_us"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security-alert@hpe.com",
          "ID": "CVE-2022-23704",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "HPE Integrated Lights-Out 4 (iLO 4)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Prior to iLO 4 version 2.80"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A potential security vulnerability has been identified in Integrated Lights-Out 4 (iLO 4). The vulnerability could allow remote Denial of Service. The vulnerability is resolved in Integrated Lights-Out 4 (iLO 4) 2.80 and later."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "remote denial of service (DoS)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04240en_us",
              "refsource": "MISC",
              "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04240en_us"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
    "assignerShortName": "hpe",
    "cveId": "CVE-2022-23704",
    "datePublished": "2022-05-09T20:17:34",
    "dateReserved": "2022-01-19T00:00:00",
    "dateUpdated": "2024-08-03T03:51:45.936Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2013-4843
Vulnerability from cvelistv5
Published
2013-11-16 02:00
Modified
2024-09-16 21:08
Severity ?
Summary
Unspecified vulnerability in HP Integrated Lights-Out 4 (iLO4) with firmware before 1.32 allows remote authenticated users to obtain sensitive information via unknown vectors.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T16:59:40.745Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "HPSBHF02939",
            "tags": [
              "vendor-advisory",
              "x_refsource_HP",
              "x_transferred"
            ],
            "url": "https://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay?docId=emr_na-c03996804"
          },
          {
            "name": "SSRT101326",
            "tags": [
              "vendor-advisory",
              "x_refsource_HP",
              "x_transferred"
            ],
            "url": "https://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay?docId=emr_na-c03996804"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Unspecified vulnerability in HP Integrated Lights-Out 4 (iLO4) with firmware before 1.32 allows remote authenticated users to obtain sensitive information via unknown vectors."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2013-11-16T02:00:00Z",
        "orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
        "shortName": "hp"
      },
      "references": [
        {
          "name": "HPSBHF02939",
          "tags": [
            "vendor-advisory",
            "x_refsource_HP"
          ],
          "url": "https://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay?docId=emr_na-c03996804"
        },
        {
          "name": "SSRT101326",
          "tags": [
            "vendor-advisory",
            "x_refsource_HP"
          ],
          "url": "https://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay?docId=emr_na-c03996804"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "hp-security-alert@hp.com",
          "ID": "CVE-2013-4843",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Unspecified vulnerability in HP Integrated Lights-Out 4 (iLO4) with firmware before 1.32 allows remote authenticated users to obtain sensitive information via unknown vectors."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "HPSBHF02939",
              "refsource": "HP",
              "url": "https://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay?docId=emr_na-c03996804"
            },
            {
              "name": "SSRT101326",
              "refsource": "HP",
              "url": "https://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay?docId=emr_na-c03996804"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
    "assignerShortName": "hp",
    "cveId": "CVE-2013-4843",
    "datePublished": "2013-11-16T02:00:00Z",
    "dateReserved": "2013-07-12T00:00:00Z",
    "dateUpdated": "2024-09-16T21:08:14.897Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-29204
Vulnerability from cvelistv5
Published
2021-05-25 13:37
Modified
2024-08-03 22:02
Severity ?
Summary
A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78.
Impacted products
Vendor Product Version
n/a HPE Integrated Lights-Out 4 (iLO 4) For HPE Gen9 servers; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers Version: Prior to HPE Integrated Lights-Out 4 (iLO 4) version 2.78
Version: Prior to HPE Integrated Lights-Out 5 (iLO 5) version 2.44
Version: unspecified
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T22:02:51.095Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "HPE Integrated Lights-Out 4 (iLO 4) For HPE Gen9 servers; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Prior to HPE Integrated Lights-Out 4 (iLO 4) version 2.78"
            },
            {
              "status": "affected",
              "version": "Prior to HPE Integrated Lights-Out 5 (iLO 5) version 2.44"
            },
            {
              "status": "affected",
              "version": "unspecified"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "remote xss",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-05-25T13:37:40",
        "orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
        "shortName": "hpe"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security-alert@hpe.com",
          "ID": "CVE-2021-29204",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "HPE Integrated Lights-Out 4 (iLO 4) For HPE Gen9 servers; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Prior to HPE Integrated Lights-Out 4 (iLO 4) version 2.78"
                          },
                          {
                            "version_value": "Prior to HPE Integrated Lights-Out 5 (iLO 5) version 2.44"
                          },
                          {
                            "version_value": ""
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "remote xss"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us",
              "refsource": "MISC",
              "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
    "assignerShortName": "hpe",
    "cveId": "CVE-2021-29204",
    "datePublished": "2021-05-25T13:37:40",
    "dateReserved": "2021-03-25T00:00:00",
    "dateUpdated": "2024-08-03T22:02:51.095Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-28083
Vulnerability from cvelistv5
Published
2023-03-20 12:34
Modified
2024-08-02 12:30
Summary
A remote Cross-site Scripting vulnerability was discovered in HPE Integrated Lights-Out 6 (iLO 6), Integrated Lights-Out 5 (iLO 5) and Integrated Lights-Out 4 (iLO 4). HPE has provided software updates to resolve this vulnerability in HPE Integrated Lights-Out.
Impacted products
Vendor Product Version
HPE Integrated Lights-Out Version: Integrated Lights-Out 6 (iLO 6)
Version: Integrated Lights-Out 5 (iLO 5)
Version: Integrated Lights-Out 4 (iLO 4)
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T12:30:23.521Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US\u0026docId=hpesbhf04456en_us"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "Integrated Lights-Out",
          "vendor": "HPE",
          "versions": [
            {
              "lessThan": "1.20",
              "status": "affected",
              "version": "Integrated Lights-Out 6 (iLO 6)",
              "versionType": "1.20"
            },
            {
              "lessThan": "2.78",
              "status": "affected",
              "version": "Integrated Lights-Out 5 (iLO 5) ",
              "versionType": "2.78"
            },
            {
              "lessThan": "2.82",
              "status": "affected",
              "version": "Integrated Lights-Out 4 (iLO 4)",
              "versionType": "2.82"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A remote Cross-site Scripting vulnerability was discovered in HPE Integrated Lights-Out 6 (iLO 6), Integrated Lights-Out 5 (iLO 5) and Integrated Lights-Out 4 (iLO 4). HPE has provided software updates to resolve this vulnerability in HPE Integrated Lights-Out."
            }
          ],
          "value": "A remote Cross-site Scripting vulnerability was discovered in HPE Integrated Lights-Out 6 (iLO 6), Integrated Lights-Out 5 (iLO 5) and Integrated Lights-Out 4 (iLO 4). HPE has provided software updates to resolve this vulnerability in HPE Integrated Lights-Out."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-63",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-63 Cross-Site Scripting (XSS)"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 8.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-03-22T04:39:47.581424Z",
        "orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
        "shortName": "hpe"
      },
      "references": [
        {
          "url": "https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US\u0026docId=hpesbhf04456en_us"
        }
      ],
      "source": {
        "advisory": "HPESBHF04456",
        "discovery": "UNKNOWN"
      },
      "title": "Potential Cross-Site scripting vulnerability in HPE Integrated Lights-Out 6 (iLO 6), Integrated Lights-Out 5 (iLO 5) and Integrated Lights-Out 4 (iLO 4). ",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
    "assignerShortName": "hpe",
    "cveId": "CVE-2023-28083",
    "datePublished": "2023-03-20T12:34:16.606Z",
    "dateReserved": "2023-03-10T14:47:44.211Z",
    "dateUpdated": "2024-08-02T12:30:23.521Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2015-5436
Vulnerability from cvelistv5
Published
2017-05-11 14:01
Modified
2024-08-06 06:50
Severity ?
Summary
A potential security vulnerability has been identified with HP Integrated Lights-Out 4 (iLO 4) firmware version 2.11 and later, but prior to version 2.30. The vulnerability could be exploited remotely resulting in Denial of Service (DoS). Note this was originally published in 2015 however the CVE entry was added in 2020.
Impacted products
Vendor Product Version
n/a HP Integrated Lights-Out 4 (iLO 4) Version: firmware version 2.11 and later, but prior to version 2.30
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T06:50:02.583Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-c04806165"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "HP Integrated Lights-Out 4 (iLO 4) ",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "firmware version 2.11 and later, but prior to version 2.30"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A potential security vulnerability has been identified with HP Integrated Lights-Out 4 (iLO 4) firmware version 2.11 and later, but prior to version 2.30. The vulnerability could be exploited remotely resulting in Denial of Service (DoS). Note this was originally published in 2015 however the CVE entry was added in 2020."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "emote Denial of Service (DoS)",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-11-23T19:23:21",
        "orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
        "shortName": "hp"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-c04806165"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "hp-security-alert@hp.com",
          "ID": "CVE-2015-5436",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "HP Integrated Lights-Out 4 (iLO 4) ",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "firmware version 2.11 and later, but prior to version 2.30"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A potential security vulnerability has been identified with HP Integrated Lights-Out 4 (iLO 4) firmware version 2.11 and later, but prior to version 2.30. The vulnerability could be exploited remotely resulting in Denial of Service (DoS). Note this was originally published in 2015 however the CVE entry was added in 2020."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "emote Denial of Service (DoS)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-c04806165",
              "refsource": "CONFIRM",
              "url": "https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-c04806165"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
    "assignerShortName": "hp",
    "cveId": "CVE-2015-5436",
    "datePublished": "2017-05-11T14:01:00",
    "dateReserved": "2015-07-07T00:00:00",
    "dateUpdated": "2024-08-06T06:50:02.583Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2013-4842
Vulnerability from cvelistv5
Published
2013-11-16 02:00
Modified
2024-09-16 19:25
Severity ?
Summary
Cross-site scripting (XSS) vulnerability in HP Integrated Lights-Out 4 (iLO4) with firmware before 1.32 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T16:59:40.992Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "HPSBHF02939",
            "tags": [
              "vendor-advisory",
              "x_refsource_HP",
              "x_transferred"
            ],
            "url": "https://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay?docId=emr_na-c03996804"
          },
          {
            "name": "SSRT101323",
            "tags": [
              "vendor-advisory",
              "x_refsource_HP",
              "x_transferred"
            ],
            "url": "https://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay?docId=emr_na-c03996804"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Cross-site scripting (XSS) vulnerability in HP Integrated Lights-Out 4 (iLO4) with firmware before 1.32 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2013-11-16T02:00:00Z",
        "orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
        "shortName": "hp"
      },
      "references": [
        {
          "name": "HPSBHF02939",
          "tags": [
            "vendor-advisory",
            "x_refsource_HP"
          ],
          "url": "https://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay?docId=emr_na-c03996804"
        },
        {
          "name": "SSRT101323",
          "tags": [
            "vendor-advisory",
            "x_refsource_HP"
          ],
          "url": "https://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay?docId=emr_na-c03996804"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "hp-security-alert@hp.com",
          "ID": "CVE-2013-4842",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Cross-site scripting (XSS) vulnerability in HP Integrated Lights-Out 4 (iLO4) with firmware before 1.32 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "HPSBHF02939",
              "refsource": "HP",
              "url": "https://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay?docId=emr_na-c03996804"
            },
            {
              "name": "SSRT101323",
              "refsource": "HP",
              "url": "https://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay?docId=emr_na-c03996804"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
    "assignerShortName": "hp",
    "cveId": "CVE-2013-4842",
    "datePublished": "2013-11-16T02:00:00Z",
    "dateReserved": "2013-07-12T00:00:00Z",
    "dateUpdated": "2024-09-16T19:25:11.882Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-29205
Vulnerability from cvelistv5
Published
2021-05-25 13:37
Modified
2024-08-03 22:02
Severity ?
Summary
A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78.
Impacted products
Vendor Product Version
n/a HPE Integrated Lights-Out 4 (iLO 4) For HPE Gen9 servers; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers Version: Prior to HPE Integrated Lights-Out 4 (iLO 4) version 2.78
Version: Prior to HPE Integrated Lights-Out 5 (iLO 5) version 2.44
Version: unspecified
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T22:02:51.271Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "HPE Integrated Lights-Out 4 (iLO 4) For HPE Gen9 servers; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Prior to HPE Integrated Lights-Out 4 (iLO 4) version 2.78"
            },
            {
              "status": "affected",
              "version": "Prior to HPE Integrated Lights-Out 5 (iLO 5) version 2.44"
            },
            {
              "status": "affected",
              "version": "unspecified"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "remote xss",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-05-25T13:37:43",
        "orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
        "shortName": "hpe"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security-alert@hpe.com",
          "ID": "CVE-2021-29205",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "HPE Integrated Lights-Out 4 (iLO 4) For HPE Gen9 servers; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Prior to HPE Integrated Lights-Out 4 (iLO 4) version 2.78"
                          },
                          {
                            "version_value": "Prior to HPE Integrated Lights-Out 5 (iLO 5) version 2.44"
                          },
                          {
                            "version_value": ""
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "remote xss"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us",
              "refsource": "MISC",
              "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
    "assignerShortName": "hpe",
    "cveId": "CVE-2021-29205",
    "datePublished": "2021-05-25T13:37:43",
    "dateReserved": "2021-03-25T00:00:00",
    "dateUpdated": "2024-08-03T22:02:51.271Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2017-12542
Vulnerability from cvelistv5
Published
2018-02-15 22:00
Modified
2024-09-17 01:55
Severity ?
Summary
A authentication bypass and execution of code vulnerability in HPE Integrated Lights-out 4 (iLO 4) version prior to 2.53 was found.
References
Impacted products
Vendor Product Version
Hewlett Packard Enterprise Integrated Lights-out 4 (iLO 4) Version: Prior to 2.53
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T18:43:55.875Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "100467",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/100467"
          },
          {
            "name": "1039222",
            "tags": [
              "vdb-entry",
              "x_refsource_SECTRACK",
              "x_transferred"
            ],
            "url": "http://www.securitytracker.com/id/1039222"
          },
          {
            "name": "44005",
            "tags": [
              "exploit",
              "x_refsource_EXPLOIT-DB",
              "x_transferred"
            ],
            "url": "https://www.exploit-db.com/exploits/44005/"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-hpesbhf03769en_us"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Integrated Lights-out 4 (iLO 4)",
          "vendor": "Hewlett Packard Enterprise",
          "versions": [
            {
              "status": "affected",
              "version": "Prior to 2.53"
            }
          ]
        }
      ],
      "datePublic": "2017-08-24T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A authentication bypass and execution of code vulnerability in HPE Integrated Lights-out 4 (iLO 4) version prior to 2.53 was found."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "authentication bypass and execution of code",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-02-16T15:57:01",
        "orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
        "shortName": "hpe"
      },
      "references": [
        {
          "name": "100467",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/100467"
        },
        {
          "name": "1039222",
          "tags": [
            "vdb-entry",
            "x_refsource_SECTRACK"
          ],
          "url": "http://www.securitytracker.com/id/1039222"
        },
        {
          "name": "44005",
          "tags": [
            "exploit",
            "x_refsource_EXPLOIT-DB"
          ],
          "url": "https://www.exploit-db.com/exploits/44005/"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-hpesbhf03769en_us"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security-alert@hpe.com",
          "DATE_PUBLIC": "2017-08-24T00:00:00",
          "ID": "CVE-2017-12542",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Integrated Lights-out 4 (iLO 4)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Prior to 2.53"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Hewlett Packard Enterprise"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A authentication bypass and execution of code vulnerability in HPE Integrated Lights-out 4 (iLO 4) version prior to 2.53 was found."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "authentication bypass and execution of code"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "100467",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/100467"
            },
            {
              "name": "1039222",
              "refsource": "SECTRACK",
              "url": "http://www.securitytracker.com/id/1039222"
            },
            {
              "name": "44005",
              "refsource": "EXPLOIT-DB",
              "url": "https://www.exploit-db.com/exploits/44005/"
            },
            {
              "name": "https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-hpesbhf03769en_us",
              "refsource": "CONFIRM",
              "url": "https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-hpesbhf03769en_us"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
    "assignerShortName": "hpe",
    "cveId": "CVE-2017-12542",
    "datePublished": "2018-02-15T22:00:00Z",
    "dateReserved": "2017-08-05T00:00:00",
    "dateUpdated": "2024-09-17T01:55:41.333Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2020-7202
Vulnerability from cvelistv5
Published
2021-01-05 14:08
Modified
2024-08-04 09:25
Severity ?
Summary
A potential security vulnerability has been identified in HPE Integrated Lights-Out 5 (iLO 5) and Integrated Lights-Out 4 (iLO 4) firmware. The vulnerability could be remotely exploited to disclose the serial number and other information.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T09:25:48.181Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04069en_us"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "HPE ProLiant Servers, Apollo Products, Converged Systems, and Synergy Compute Modules with Integrated Lights-Out 5 (iLO 5), or Integrated Lights-Out 4 (iLO 4)",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Prior to iLO 5 v2.31"
            },
            {
              "status": "affected",
              "version": "Prior to iLO 4 v2.76"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A potential security vulnerability has been identified in HPE Integrated Lights-Out 5 (iLO 5) and Integrated Lights-Out 4 (iLO 4) firmware. The vulnerability could be remotely exploited to disclose the serial number and other information."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Remote disclosure of information",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-01-05T14:08:28",
        "orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
        "shortName": "hpe"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04069en_us"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security-alert@hpe.com",
          "ID": "CVE-2020-7202",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "HPE ProLiant Servers, Apollo Products, Converged Systems, and Synergy Compute Modules with Integrated Lights-Out 5 (iLO 5), or Integrated Lights-Out 4 (iLO 4)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Prior to iLO 5 v2.31"
                          },
                          {
                            "version_value": "Prior to iLO 4 v2.76"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A potential security vulnerability has been identified in HPE Integrated Lights-Out 5 (iLO 5) and Integrated Lights-Out 4 (iLO 4) firmware. The vulnerability could be remotely exploited to disclose the serial number and other information."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Remote disclosure of information"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04069en_us",
              "refsource": "MISC",
              "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04069en_us"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
    "assignerShortName": "hpe",
    "cveId": "CVE-2020-7202",
    "datePublished": "2021-01-05T14:08:28",
    "dateReserved": "2020-01-16T00:00:00",
    "dateUpdated": "2024-08-04T09:25:48.181Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-29202
Vulnerability from cvelistv5
Published
2021-05-25 13:24
Modified
2024-08-03 22:02
Severity ?
Summary
A local buffer overflow vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78.
Impacted products
Vendor Product Version
n/a HPE Integrated Lights-Out 4 (iLO 4) For HPE Gen9 servers; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers Version: Prior to HPE Integrated Lights-Out 4 (iLO 4) version 2.78
Version: Prior to HPE Integrated Lights-Out 5 (iLO 5) version 2.44
Version: unspecified
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T22:02:50.533Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "HPE Integrated Lights-Out 4 (iLO 4) For HPE Gen9 servers; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Prior to HPE Integrated Lights-Out 4 (iLO 4) version 2.78"
            },
            {
              "status": "affected",
              "version": "Prior to HPE Integrated Lights-Out 5 (iLO 5) version 2.44"
            },
            {
              "status": "affected",
              "version": "unspecified"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A local buffer overflow vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "local buffer overflow",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-05-25T13:24:19",
        "orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
        "shortName": "hpe"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security-alert@hpe.com",
          "ID": "CVE-2021-29202",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "HPE Integrated Lights-Out 4 (iLO 4) For HPE Gen9 servers; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Prior to HPE Integrated Lights-Out 4 (iLO 4) version 2.78"
                          },
                          {
                            "version_value": "Prior to HPE Integrated Lights-Out 5 (iLO 5) version 2.44"
                          },
                          {
                            "version_value": ""
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A local buffer overflow vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "local buffer overflow"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us",
              "refsource": "MISC",
              "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
    "assignerShortName": "hpe",
    "cveId": "CVE-2021-29202",
    "datePublished": "2021-05-25T13:24:19",
    "dateReserved": "2021-03-25T00:00:00",
    "dateUpdated": "2024-08-03T22:02:50.533Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-29209
Vulnerability from cvelistv5
Published
2021-05-25 14:32
Modified
2024-08-03 22:02
Severity ?
Summary
A remote dom xss, crlf injection vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78.
Impacted products
Vendor Product Version
n/a HPE Integrated Lights-Out 4 (iLO 4) For HPE Gen9 servers; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers Version: Prior to HPE Integrated Lights-Out 4 (iLO 4) version 2.78
Version: Prior to HPE Integrated Lights-Out 5 (iLO 5) version 2.44
Version: unspecified
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T22:02:51.204Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "HPE Integrated Lights-Out 4 (iLO 4) For HPE Gen9 servers; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Prior to HPE Integrated Lights-Out 4 (iLO 4) version 2.78"
            },
            {
              "status": "affected",
              "version": "Prior to HPE Integrated Lights-Out 5 (iLO 5) version 2.44"
            },
            {
              "status": "affected",
              "version": "unspecified"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A remote dom xss, crlf injection vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "remote dom xss, crlf injection",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-05-25T14:32:49",
        "orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
        "shortName": "hpe"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security-alert@hpe.com",
          "ID": "CVE-2021-29209",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "HPE Integrated Lights-Out 4 (iLO 4) For HPE Gen9 servers; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Prior to HPE Integrated Lights-Out 4 (iLO 4) version 2.78"
                          },
                          {
                            "version_value": "Prior to HPE Integrated Lights-Out 5 (iLO 5) version 2.44"
                          },
                          {
                            "version_value": ""
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A remote dom xss, crlf injection vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "remote dom xss, crlf injection"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us",
              "refsource": "MISC",
              "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
    "assignerShortName": "hpe",
    "cveId": "CVE-2021-29209",
    "datePublished": "2021-05-25T14:32:49",
    "dateReserved": "2021-03-25T00:00:00",
    "dateUpdated": "2024-08-03T22:02:51.204Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-29207
Vulnerability from cvelistv5
Published
2021-05-25 13:53
Modified
2024-08-03 22:02
Severity ?
Summary
A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78.
Impacted products
Vendor Product Version
n/a HPE Integrated Lights-Out 4 (iLO 4) For HPE Gen9 servers; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers Version: Prior to HPE Integrated Lights-Out 4 (iLO 4) version 2.78
Version: Prior to HPE Integrated Lights-Out 5 (iLO 5) version 2.44
Version: unspecified
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T22:02:51.367Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "HPE Integrated Lights-Out 4 (iLO 4) For HPE Gen9 servers; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Prior to HPE Integrated Lights-Out 4 (iLO 4) version 2.78"
            },
            {
              "status": "affected",
              "version": "Prior to HPE Integrated Lights-Out 5 (iLO 5) version 2.44"
            },
            {
              "status": "affected",
              "version": "unspecified"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "remote xss",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-05-25T13:53:29",
        "orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
        "shortName": "hpe"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security-alert@hpe.com",
          "ID": "CVE-2021-29207",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "HPE Integrated Lights-Out 4 (iLO 4) For HPE Gen9 servers; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Prior to HPE Integrated Lights-Out 4 (iLO 4) version 2.78"
                          },
                          {
                            "version_value": "Prior to HPE Integrated Lights-Out 5 (iLO 5) version 2.44"
                          },
                          {
                            "version_value": ""
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "remote xss"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us",
              "refsource": "MISC",
              "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
    "assignerShortName": "hpe",
    "cveId": "CVE-2021-29207",
    "datePublished": "2021-05-25T13:53:29",
    "dateReserved": "2021-03-25T00:00:00",
    "dateUpdated": "2024-08-03T22:02:51.367Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-29201
Vulnerability from cvelistv5
Published
2021-05-25 13:24
Modified
2024-08-03 22:02
Severity ?
Summary
A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78.
Impacted products
Vendor Product Version
n/a HPE Integrated Lights-Out 4 (iLO 4) For HPE Gen9 servers; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers Version: Prior to HPE Integrated Lights-Out 4 (iLO 4) version 2.78
Version: Prior to HPE Integrated Lights-Out 5 (iLO 5) version 2.44
Version: unspecified
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T22:02:51.300Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "HPE Integrated Lights-Out 4 (iLO 4) For HPE Gen9 servers; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Prior to HPE Integrated Lights-Out 4 (iLO 4) version 2.78"
            },
            {
              "status": "affected",
              "version": "Prior to HPE Integrated Lights-Out 5 (iLO 5) version 2.44"
            },
            {
              "status": "affected",
              "version": "unspecified"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "remote xss",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-05-25T13:24:14",
        "orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
        "shortName": "hpe"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security-alert@hpe.com",
          "ID": "CVE-2021-29201",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "HPE Integrated Lights-Out 4 (iLO 4) For HPE Gen9 servers; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Prior to HPE Integrated Lights-Out 4 (iLO 4) version 2.78"
                          },
                          {
                            "version_value": "Prior to HPE Integrated Lights-Out 5 (iLO 5) version 2.44"
                          },
                          {
                            "version_value": ""
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "remote xss"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us",
              "refsource": "MISC",
              "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
    "assignerShortName": "hpe",
    "cveId": "CVE-2021-29201",
    "datePublished": "2021-05-25T13:24:14",
    "dateReserved": "2021-03-25T00:00:00",
    "dateUpdated": "2024-08-03T22:02:51.300Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-29208
Vulnerability from cvelistv5
Published
2021-05-25 14:32
Modified
2024-08-03 22:02
Severity ?
Summary
A remote dom xss, crlf injection vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78.
Impacted products
Vendor Product Version
n/a HPE Integrated Lights-Out 4 (iLO 4) For HPE Gen9 servers; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers Version: Prior to HPE Integrated Lights-Out 4 (iLO 4) version 2.78
Version: Prior to HPE Integrated Lights-Out 5 (iLO 5) version 2.44
Version: unspecified
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T22:02:51.221Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "HPE Integrated Lights-Out 4 (iLO 4) For HPE Gen9 servers; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Prior to HPE Integrated Lights-Out 4 (iLO 4) version 2.78"
            },
            {
              "status": "affected",
              "version": "Prior to HPE Integrated Lights-Out 5 (iLO 5) version 2.44"
            },
            {
              "status": "affected",
              "version": "unspecified"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A remote dom xss, crlf injection vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "remote dom xss, crlf injection",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-05-25T14:32:42",
        "orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
        "shortName": "hpe"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security-alert@hpe.com",
          "ID": "CVE-2021-29208",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "HPE Integrated Lights-Out 4 (iLO 4) For HPE Gen9 servers; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Prior to HPE Integrated Lights-Out 4 (iLO 4) version 2.78"
                          },
                          {
                            "version_value": "Prior to HPE Integrated Lights-Out 5 (iLO 5) version 2.44"
                          },
                          {
                            "version_value": ""
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A remote dom xss, crlf injection vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "remote dom xss, crlf injection"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us",
              "refsource": "MISC",
              "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
    "assignerShortName": "hpe",
    "cveId": "CVE-2021-29208",
    "datePublished": "2021-05-25T14:32:42",
    "dateReserved": "2021-03-25T00:00:00",
    "dateUpdated": "2024-08-03T22:02:51.221Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2016-4375
Vulnerability from cvelistv5
Published
2016-09-08 16:00
Modified
2024-08-06 00:25
Severity ?
Summary
Multiple unspecified vulnerabilities in HPE Integrated Lights-Out 3 (aka iLO 3) firmware before 1.88, Integrated Lights-Out 4 (aka iLO 4) firmware before 2.44, and Integrated Lights-Out 4 (aka iLO 4) mRCA firmware before 2.32 allow remote attackers to obtain sensitive information, modify data, or cause a denial of service via unknown vectors.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T00:25:14.571Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "1036629",
            "tags": [
              "vdb-entry",
              "x_refsource_SECTRACK",
              "x_transferred"
            ],
            "url": "http://www.securitytracker.com/id/1036629"
          },
          {
            "name": "92484",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/92484"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://h20566.www2.hpe.com/portal/site/hpsc/public/kb/docDisplay?docId=emr_na-c05236950"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2016-08-12T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Multiple unspecified vulnerabilities in HPE Integrated Lights-Out 3 (aka iLO 3) firmware before 1.88, Integrated Lights-Out 4 (aka iLO 4) firmware before 2.44, and Integrated Lights-Out 4 (aka iLO 4) mRCA firmware before 2.32 allow remote attackers to obtain sensitive information, modify data, or cause a denial of service via unknown vectors."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2016-11-25T20:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "name": "1036629",
          "tags": [
            "vdb-entry",
            "x_refsource_SECTRACK"
          ],
          "url": "http://www.securitytracker.com/id/1036629"
        },
        {
          "name": "92484",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/92484"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://h20566.www2.hpe.com/portal/site/hpsc/public/kb/docDisplay?docId=emr_na-c05236950"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2016-4375",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Multiple unspecified vulnerabilities in HPE Integrated Lights-Out 3 (aka iLO 3) firmware before 1.88, Integrated Lights-Out 4 (aka iLO 4) firmware before 2.44, and Integrated Lights-Out 4 (aka iLO 4) mRCA firmware before 2.32 allow remote attackers to obtain sensitive information, modify data, or cause a denial of service via unknown vectors."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "1036629",
              "refsource": "SECTRACK",
              "url": "http://www.securitytracker.com/id/1036629"
            },
            {
              "name": "92484",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/92484"
            },
            {
              "name": "https://h20566.www2.hpe.com/portal/site/hpsc/public/kb/docDisplay?docId=emr_na-c05236950",
              "refsource": "CONFIRM",
              "url": "https://h20566.www2.hpe.com/portal/site/hpsc/public/kb/docDisplay?docId=emr_na-c05236950"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2016-4375",
    "datePublished": "2016-09-08T16:00:00",
    "dateReserved": "2016-04-29T00:00:00",
    "dateUpdated": "2024-08-06T00:25:14.571Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-29206
Vulnerability from cvelistv5
Published
2021-05-25 13:53
Modified
2024-08-03 22:02
Severity ?
Summary
A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78.
Impacted products
Vendor Product Version
n/a HPE Integrated Lights-Out 4 (iLO 4) For HPE Gen9 servers; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers Version: Prior to HPE Integrated Lights-Out 4 (iLO 4) version 2.78
Version: Prior to HPE Integrated Lights-Out 5 (iLO 5) version 2.44
Version: unspecified
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T22:02:51.072Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "HPE Integrated Lights-Out 4 (iLO 4) For HPE Gen9 servers; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Prior to HPE Integrated Lights-Out 4 (iLO 4) version 2.78"
            },
            {
              "status": "affected",
              "version": "Prior to HPE Integrated Lights-Out 5 (iLO 5) version 2.44"
            },
            {
              "status": "affected",
              "version": "unspecified"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "remote xss",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-05-25T13:53:25",
        "orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
        "shortName": "hpe"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security-alert@hpe.com",
          "ID": "CVE-2021-29206",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "HPE Integrated Lights-Out 4 (iLO 4) For HPE Gen9 servers; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Prior to HPE Integrated Lights-Out 4 (iLO 4) version 2.78"
                          },
                          {
                            "version_value": "Prior to HPE Integrated Lights-Out 5 (iLO 5) version 2.44"
                          },
                          {
                            "version_value": ""
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "remote xss"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us",
              "refsource": "MISC",
              "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
    "assignerShortName": "hpe",
    "cveId": "CVE-2021-29206",
    "datePublished": "2021-05-25T13:53:25",
    "dateReserved": "2021-03-25T00:00:00",
    "dateUpdated": "2024-08-03T22:02:51.072Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-29211
Vulnerability from cvelistv5
Published
2021-05-25 14:11
Modified
2024-08-03 22:02
Severity ?
Summary
A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78.
Impacted products
Vendor Product Version
n/a HPE Integrated Lights-Out 4 (iLO 4) For HPE Gen9 servers; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers Version: Prior to HPE Integrated Lights-Out 4 (iLO 4) version 2.78
Version: Prior to HPE Integrated Lights-Out 5 (iLO 5) version 2.44
Version: unspecified
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T22:02:51.313Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "HPE Integrated Lights-Out 4 (iLO 4) For HPE Gen9 servers; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Prior to HPE Integrated Lights-Out 4 (iLO 4) version 2.78"
            },
            {
              "status": "affected",
              "version": "Prior to HPE Integrated Lights-Out 5 (iLO 5) version 2.44"
            },
            {
              "status": "affected",
              "version": "unspecified"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "remote xss",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-05-25T14:11:09",
        "orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
        "shortName": "hpe"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security-alert@hpe.com",
          "ID": "CVE-2021-29211",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "HPE Integrated Lights-Out 4 (iLO 4) For HPE Gen9 servers; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Prior to HPE Integrated Lights-Out 4 (iLO 4) version 2.78"
                          },
                          {
                            "version_value": "Prior to HPE Integrated Lights-Out 5 (iLO 5) version 2.44"
                          },
                          {
                            "version_value": ""
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "remote xss"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us",
              "refsource": "MISC",
              "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
    "assignerShortName": "hpe",
    "cveId": "CVE-2021-29211",
    "datePublished": "2021-05-25T14:11:09",
    "dateReserved": "2021-03-25T00:00:00",
    "dateUpdated": "2024-08-03T22:02:51.313Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-29210
Vulnerability from cvelistv5
Published
2021-05-25 14:11
Modified
2024-08-03 22:02
Severity ?
Summary
A remote dom xss, crlf injection vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78.
Impacted products
Vendor Product Version
n/a HPE Integrated Lights-Out 4 (iLO 4) For HPE Gen9 servers; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers Version: Prior to HPE Integrated Lights-Out 4 (iLO 4) version 2.78
Version: Prior to HPE Integrated Lights-Out 5 (iLO 5) version 2.44
Version: unspecified
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T22:02:51.297Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "HPE Integrated Lights-Out 4 (iLO 4) For HPE Gen9 servers; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Prior to HPE Integrated Lights-Out 4 (iLO 4) version 2.78"
            },
            {
              "status": "affected",
              "version": "Prior to HPE Integrated Lights-Out 5 (iLO 5) version 2.44"
            },
            {
              "status": "affected",
              "version": "unspecified"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A remote dom xss, crlf injection vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "remote dom xss, crlf injection",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-05-25T14:11:03",
        "orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
        "shortName": "hpe"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security-alert@hpe.com",
          "ID": "CVE-2021-29210",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "HPE Integrated Lights-Out 4 (iLO 4) For HPE Gen9 servers; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Prior to HPE Integrated Lights-Out 4 (iLO 4) version 2.78"
                          },
                          {
                            "version_value": "Prior to HPE Integrated Lights-Out 5 (iLO 5) version 2.44"
                          },
                          {
                            "version_value": ""
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A remote dom xss, crlf injection vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "remote dom xss, crlf injection"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us",
              "refsource": "MISC",
              "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
    "assignerShortName": "hpe",
    "cveId": "CVE-2021-29210",
    "datePublished": "2021-05-25T14:11:03",
    "dateReserved": "2021-03-25T00:00:00",
    "dateUpdated": "2024-08-03T22:02:51.297Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}