Search criteria
3 vulnerabilities found for intouch_machine_edition_2017 by industrial-software
FKIE_CVE-2018-8840
Vulnerability from fkie_nvd - Published: 2018-04-18 20:29 - Updated: 2024-11-21 04:14
Severity ?
Summary
A remote attacker could send a carefully crafted packet in InduSoft Web Studio v8.1 and prior versions, and/or InTouch Machine Edition 2017 v8.1 and prior versions during a tag, alarm, or event related action such as read and write, which may allow remote code execution.
References
| URL | Tags | ||
|---|---|---|---|
| ics-cert@hq.dhs.gov | http://software.schneider-electric.com/pdf/security-bulletin/lfsec00000125/ | Third Party Advisory | |
| ics-cert@hq.dhs.gov | http://www.securityfocus.com/bid/103949 | Third Party Advisory, VDB Entry | |
| ics-cert@hq.dhs.gov | https://ics-cert.us-cert.gov/advisories/ICSA-18-107-01 | Third Party Advisory, US Government Resource | |
| ics-cert@hq.dhs.gov | https://www.tenable.com/security/research/tra-2018-07 | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | http://software.schneider-electric.com/pdf/security-bulletin/lfsec00000125/ | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/103949 | Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://ics-cert.us-cert.gov/advisories/ICSA-18-107-01 | Third Party Advisory, US Government Resource | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.tenable.com/security/research/tra-2018-07 | Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| indusoft | web_studio | * | |
| industrial-software | intouch_machine_edition_2017 | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:indusoft:web_studio:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A6BF553A-0EC5-4652-B8F7-FB27013DE9E3",
"versionEndIncluding": "8.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:industrial-software:intouch_machine_edition_2017:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2107AE24-C696-462B-8881-5F9E7FC90624",
"versionEndIncluding": "8.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A remote attacker could send a carefully crafted packet in InduSoft Web Studio v8.1 and prior versions, and/or InTouch Machine Edition 2017 v8.1 and prior versions during a tag, alarm, or event related action such as read and write, which may allow remote code execution."
},
{
"lang": "es",
"value": "Un atacante remoto podr\u00eda enviar un paquete cuidadosamente manipulado en InduSoft Web Studio, en versiones 8.1 y anteriores, y/o en InTouch Machine Edition 2017, en versiones 8.1 y anteriores, durante una acci\u00f3n relacionada con una etiqueta, alarma o evento como la lectura o escritura. Esto podr\u00eda permitir la ejecuci\u00f3n remota de c\u00f3digo."
}
],
"id": "CVE-2018-8840",
"lastModified": "2024-11-21T04:14:25.670",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": true,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2018-04-18T20:29:00.920",
"references": [
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Third Party Advisory"
],
"url": "http://software.schneider-electric.com/pdf/security-bulletin/lfsec00000125/"
},
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/103949"
},
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-107-01"
},
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Third Party Advisory"
],
"url": "https://www.tenable.com/security/research/tra-2018-07"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "http://software.schneider-electric.com/pdf/security-bulletin/lfsec00000125/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/103949"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-107-01"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://www.tenable.com/security/research/tra-2018-07"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-121"
}
],
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-119"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
CVE-2018-8840 (GCVE-0-2018-8840)
Vulnerability from cvelistv5 – Published: 2018-04-18 20:00 – Updated: 2024-09-16 17:53
VLAI?
Summary
A remote attacker could send a carefully crafted packet in InduSoft Web Studio v8.1 and prior versions, and/or InTouch Machine Edition 2017 v8.1 and prior versions during a tag, alarm, or event related action such as read and write, which may allow remote code execution.
Severity ?
No CVSS data available.
CWE
- CWE-121 - STACK-BASED BUFFER OVERFLOW CWE-121
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| ICS-CERT | Schneider Electric InduSoft Web Studio and InTouch Machine Edition |
Affected:
InduSoft Web Studio v8.1 and prior versions, and InTouch Machine Edition 2017 v8.1 and prior versions.
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T07:02:26.247Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "103949",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/103949"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://software.schneider-electric.com/pdf/security-bulletin/lfsec00000125/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2018-07"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-107-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Schneider Electric InduSoft Web Studio and InTouch Machine Edition",
"vendor": "ICS-CERT",
"versions": [
{
"status": "affected",
"version": "InduSoft Web Studio v8.1 and prior versions, and InTouch Machine Edition 2017 v8.1 and prior versions."
}
]
}
],
"datePublic": "2018-04-06T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A remote attacker could send a carefully crafted packet in InduSoft Web Studio v8.1 and prior versions, and/or InTouch Machine Edition 2017 v8.1 and prior versions during a tag, alarm, or event related action such as read and write, which may allow remote code execution."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "STACK-BASED BUFFER OVERFLOW CWE-121",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-04-24T09:57:01",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"name": "103949",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/103949"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://software.schneider-electric.com/pdf/security-bulletin/lfsec00000125/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2018-07"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-107-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2018-04-06T00:00:00",
"ID": "CVE-2018-8840",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Schneider Electric InduSoft Web Studio and InTouch Machine Edition",
"version": {
"version_data": [
{
"version_value": "InduSoft Web Studio v8.1 and prior versions, and InTouch Machine Edition 2017 v8.1 and prior versions."
}
]
}
}
]
},
"vendor_name": "ICS-CERT"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A remote attacker could send a carefully crafted packet in InduSoft Web Studio v8.1 and prior versions, and/or InTouch Machine Edition 2017 v8.1 and prior versions during a tag, alarm, or event related action such as read and write, which may allow remote code execution."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "STACK-BASED BUFFER OVERFLOW CWE-121"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "103949",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/103949"
},
{
"name": "http://software.schneider-electric.com/pdf/security-bulletin/lfsec00000125/",
"refsource": "MISC",
"url": "http://software.schneider-electric.com/pdf/security-bulletin/lfsec00000125/"
},
{
"name": "https://www.tenable.com/security/research/tra-2018-07",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2018-07"
},
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-107-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-107-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2018-8840",
"datePublished": "2018-04-18T20:00:00Z",
"dateReserved": "2018-03-20T00:00:00",
"dateUpdated": "2024-09-16T17:53:19.851Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-8840 (GCVE-0-2018-8840)
Vulnerability from nvd – Published: 2018-04-18 20:00 – Updated: 2024-09-16 17:53
VLAI?
Summary
A remote attacker could send a carefully crafted packet in InduSoft Web Studio v8.1 and prior versions, and/or InTouch Machine Edition 2017 v8.1 and prior versions during a tag, alarm, or event related action such as read and write, which may allow remote code execution.
Severity ?
No CVSS data available.
CWE
- CWE-121 - STACK-BASED BUFFER OVERFLOW CWE-121
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| ICS-CERT | Schneider Electric InduSoft Web Studio and InTouch Machine Edition |
Affected:
InduSoft Web Studio v8.1 and prior versions, and InTouch Machine Edition 2017 v8.1 and prior versions.
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T07:02:26.247Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "103949",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/103949"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://software.schneider-electric.com/pdf/security-bulletin/lfsec00000125/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2018-07"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-107-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Schneider Electric InduSoft Web Studio and InTouch Machine Edition",
"vendor": "ICS-CERT",
"versions": [
{
"status": "affected",
"version": "InduSoft Web Studio v8.1 and prior versions, and InTouch Machine Edition 2017 v8.1 and prior versions."
}
]
}
],
"datePublic": "2018-04-06T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A remote attacker could send a carefully crafted packet in InduSoft Web Studio v8.1 and prior versions, and/or InTouch Machine Edition 2017 v8.1 and prior versions during a tag, alarm, or event related action such as read and write, which may allow remote code execution."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "STACK-BASED BUFFER OVERFLOW CWE-121",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-04-24T09:57:01",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"name": "103949",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/103949"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://software.schneider-electric.com/pdf/security-bulletin/lfsec00000125/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2018-07"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-107-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2018-04-06T00:00:00",
"ID": "CVE-2018-8840",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Schneider Electric InduSoft Web Studio and InTouch Machine Edition",
"version": {
"version_data": [
{
"version_value": "InduSoft Web Studio v8.1 and prior versions, and InTouch Machine Edition 2017 v8.1 and prior versions."
}
]
}
}
]
},
"vendor_name": "ICS-CERT"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A remote attacker could send a carefully crafted packet in InduSoft Web Studio v8.1 and prior versions, and/or InTouch Machine Edition 2017 v8.1 and prior versions during a tag, alarm, or event related action such as read and write, which may allow remote code execution."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "STACK-BASED BUFFER OVERFLOW CWE-121"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "103949",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/103949"
},
{
"name": "http://software.schneider-electric.com/pdf/security-bulletin/lfsec00000125/",
"refsource": "MISC",
"url": "http://software.schneider-electric.com/pdf/security-bulletin/lfsec00000125/"
},
{
"name": "https://www.tenable.com/security/research/tra-2018-07",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2018-07"
},
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-107-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-107-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2018-8840",
"datePublished": "2018-04-18T20:00:00Z",
"dateReserved": "2018-03-20T00:00:00",
"dateUpdated": "2024-09-16T17:53:19.851Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}