Search criteria
3 vulnerabilities found for micom_s1_studio by schneider-electric
FKIE_CVE-2013-0687
Vulnerability from fkie_nvd - Published: 2013-04-18 02:25 - Updated: 2025-04-11 00:51
Severity ?
Summary
The installer routine in Schneider Electric MiCOM S1 Studio uses world-writable permissions for executable files, which allows local users to modify the service or the configuration files, and consequently gain privileges or trigger incorrect protective-relay operation, via a Trojan horse executable file.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| schneider-electric | micom_s1_studio | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:micom_s1_studio:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EEB9253D-8683-4191-A63F-086828E52374",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "The installer routine in Schneider Electric MiCOM S1 Studio uses world-writable permissions for executable files, which allows local users to modify the service or the configuration files, and consequently gain privileges or trigger incorrect protective-relay operation, via a Trojan horse executable file."
},
{
"lang": "es",
"value": "La rutina de instalaci\u00f3n en Schneider Electric MiCOM S1 Studio utiliza permisos globales de escribir de archivos ejecutables, lo que permite a usuarios locales modificar el servicio o los archivos de configuraci\u00f3n, y por lo tanto obtener privilegios o disparar operaciones incorrectas protectiven-relay, a trav\u00e9s de un archivo ejecutable troyano"
}
],
"id": "CVE-2013-0687",
"lastModified": "2025-04-11T00:51:21.963",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "LOCAL",
"authentication": "SINGLE",
"availabilityImpact": "COMPLETE",
"baseScore": 6.6,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:L/AC:M/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 2.7,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
]
},
"published": "2013-04-18T02:25:37.237",
"references": [
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Vendor Advisory"
],
"url": "http://download.schneider-electric.com/files?p_File_Id=56543584\u0026p_File_Name=SEVD-2013-087-01-MiCOM-S1-Studio-SW.pdf"
},
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"US Government Resource"
],
"url": "http://ics-cert.us-cert.gov/pdf/ICSA-13-100-01.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "http://download.schneider-electric.com/files?p_File_Id=56543584\u0026p_File_Name=SEVD-2013-087-01-MiCOM-S1-Studio-SW.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"US Government Resource"
],
"url": "http://ics-cert.us-cert.gov/pdf/ICSA-13-100-01.pdf"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-264"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
CVE-2013-0687 (GCVE-0-2013-0687)
Vulnerability from cvelistv5 – Published: 2013-04-18 01:00 – Updated: 2024-09-16 18:12
VLAI?
Summary
The installer routine in Schneider Electric MiCOM S1 Studio uses world-writable permissions for executable files, which allows local users to modify the service or the configuration files, and consequently gain privileges or trigger incorrect protective-relay operation, via a Trojan horse executable file.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T14:33:05.591Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://ics-cert.us-cert.gov/pdf/ICSA-13-100-01.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://download.schneider-electric.com/files?p_File_Id=56543584\u0026p_File_Name=SEVD-2013-087-01-MiCOM-S1-Studio-SW.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The installer routine in Schneider Electric MiCOM S1 Studio uses world-writable permissions for executable files, which allows local users to modify the service or the configuration files, and consequently gain privileges or trigger incorrect protective-relay operation, via a Trojan horse executable file."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2013-04-18T01:00:00Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "http://ics-cert.us-cert.gov/pdf/ICSA-13-100-01.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://download.schneider-electric.com/files?p_File_Id=56543584\u0026p_File_Name=SEVD-2013-087-01-MiCOM-S1-Studio-SW.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2013-0687",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The installer routine in Schneider Electric MiCOM S1 Studio uses world-writable permissions for executable files, which allows local users to modify the service or the configuration files, and consequently gain privileges or trigger incorrect protective-relay operation, via a Trojan horse executable file."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://ics-cert.us-cert.gov/pdf/ICSA-13-100-01.pdf",
"refsource": "MISC",
"url": "http://ics-cert.us-cert.gov/pdf/ICSA-13-100-01.pdf"
},
{
"name": "http://download.schneider-electric.com/files?p_File_Id=56543584\u0026p_File_Name=SEVD-2013-087-01-MiCOM-S1-Studio-SW.pdf",
"refsource": "CONFIRM",
"url": "http://download.schneider-electric.com/files?p_File_Id=56543584\u0026p_File_Name=SEVD-2013-087-01-MiCOM-S1-Studio-SW.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2013-0687",
"datePublished": "2013-04-18T01:00:00Z",
"dateReserved": "2012-12-19T00:00:00Z",
"dateUpdated": "2024-09-16T18:12:50.510Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2013-0687 (GCVE-0-2013-0687)
Vulnerability from nvd – Published: 2013-04-18 01:00 – Updated: 2024-09-16 18:12
VLAI?
Summary
The installer routine in Schneider Electric MiCOM S1 Studio uses world-writable permissions for executable files, which allows local users to modify the service or the configuration files, and consequently gain privileges or trigger incorrect protective-relay operation, via a Trojan horse executable file.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T14:33:05.591Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://ics-cert.us-cert.gov/pdf/ICSA-13-100-01.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://download.schneider-electric.com/files?p_File_Id=56543584\u0026p_File_Name=SEVD-2013-087-01-MiCOM-S1-Studio-SW.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The installer routine in Schneider Electric MiCOM S1 Studio uses world-writable permissions for executable files, which allows local users to modify the service or the configuration files, and consequently gain privileges or trigger incorrect protective-relay operation, via a Trojan horse executable file."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2013-04-18T01:00:00Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "http://ics-cert.us-cert.gov/pdf/ICSA-13-100-01.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://download.schneider-electric.com/files?p_File_Id=56543584\u0026p_File_Name=SEVD-2013-087-01-MiCOM-S1-Studio-SW.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2013-0687",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The installer routine in Schneider Electric MiCOM S1 Studio uses world-writable permissions for executable files, which allows local users to modify the service or the configuration files, and consequently gain privileges or trigger incorrect protective-relay operation, via a Trojan horse executable file."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://ics-cert.us-cert.gov/pdf/ICSA-13-100-01.pdf",
"refsource": "MISC",
"url": "http://ics-cert.us-cert.gov/pdf/ICSA-13-100-01.pdf"
},
{
"name": "http://download.schneider-electric.com/files?p_File_Id=56543584\u0026p_File_Name=SEVD-2013-087-01-MiCOM-S1-Studio-SW.pdf",
"refsource": "CONFIRM",
"url": "http://download.schneider-electric.com/files?p_File_Id=56543584\u0026p_File_Name=SEVD-2013-087-01-MiCOM-S1-Studio-SW.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2013-0687",
"datePublished": "2013-04-18T01:00:00Z",
"dateReserved": "2012-12-19T00:00:00Z",
"dateUpdated": "2024-09-16T18:12:50.510Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}