Search criteria
10 vulnerabilities found for mofi4500-4gxelte by mofinetwork
VAR-202102-0160
Vulnerability from variot - Updated: 2023-12-18 13:56An issue was discovered on Mofi Network MOFI4500-4GXeLTE 4.1.5-std devices. The authentication function passes untrusted data to the operating system without proper sanitization. A crafted request can be sent to execute arbitrary commands as root. Mofi Network MOFI4500-4GXeLTE is a wireless router of Mofi Network Company. No detailed vulnerability details are currently provided
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202102-0160",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "mofi4500-4gxelte",
"scope": "eq",
"trust": 1.0,
"vendor": "mofinetwork",
"version": "4.1.5-std"
},
{
"model": "network mofi4500-4gxelte 4.1.5-std",
"scope": null,
"trust": 0.6,
"vendor": "mofi",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13964"
},
{
"db": "NVD",
"id": "CVE-2020-15836"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:mofinetwork:mofi4500-4gxelte_firmware:4.1.5-std:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:mofinetwork:mofi4500-4gxelte:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2020-15836"
}
]
},
"cve": "CVE-2020-15836",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2021-13964",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULMON",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CVE-2020-15836",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "HIGH",
"trust": 0.1,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2020-15836",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "CNVD",
"id": "CNVD-2021-13964",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202101-2601",
"trust": 0.6,
"value": "CRITICAL"
},
{
"author": "VULMON",
"id": "CVE-2020-15836",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13964"
},
{
"db": "VULMON",
"id": "CVE-2020-15836"
},
{
"db": "NVD",
"id": "CVE-2020-15836"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2601"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "An issue was discovered on Mofi Network MOFI4500-4GXeLTE 4.1.5-std devices. The authentication function passes untrusted data to the operating system without proper sanitization. A crafted request can be sent to execute arbitrary commands as root. Mofi Network MOFI4500-4GXeLTE is a wireless router of Mofi Network Company. No detailed vulnerability details are currently provided",
"sources": [
{
"db": "NVD",
"id": "CVE-2020-15836"
},
{
"db": "CNVD",
"id": "CNVD-2021-13964"
},
{
"db": "VULMON",
"id": "CVE-2020-15836"
}
],
"trust": 1.53
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2020-15836",
"trust": 2.3
},
{
"db": "CNVD",
"id": "CNVD-2021-13964",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2601",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2020-15836",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13964"
},
{
"db": "VULMON",
"id": "CVE-2020-15836"
},
{
"db": "NVD",
"id": "CVE-2020-15836"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2601"
}
]
},
"id": "VAR-202102-0160",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13964"
}
],
"trust": 1.6
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13964"
}
]
},
"last_update_date": "2023-12-18T13:56:00.700000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Mofi Network MOFI4500-4GXeLTE unauthorized RCE vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/250476"
},
{
"title": "Mofi Network MOFI4500-4GXeLTE Security vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=140633"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13964"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2601"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "NVD-CWE-noinfo",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2020-15836"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.7,
"url": "https://mofinetwork.com/index.php?main_page=page\u0026id=14"
},
{
"trust": 1.7,
"url": "https://www.criticalstart.com/critical-vulnerabilities-discovered-in-mofi-routers/"
},
{
"trust": 1.2,
"url": "https://nvd.nist.gov/vuln/detail/cve-2020-15836"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13964"
},
{
"db": "VULMON",
"id": "CVE-2020-15836"
},
{
"db": "NVD",
"id": "CVE-2020-15836"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2601"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2021-13964"
},
{
"db": "VULMON",
"id": "CVE-2020-15836"
},
{
"db": "NVD",
"id": "CVE-2020-15836"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2601"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-03-03T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-13964"
},
{
"date": "2021-02-01T00:00:00",
"db": "VULMON",
"id": "CVE-2020-15836"
},
{
"date": "2021-02-01T02:15:15.253000",
"db": "NVD",
"id": "CVE-2020-15836"
},
{
"date": "2021-01-31T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202101-2601"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-03-03T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-13964"
},
{
"date": "2021-02-03T00:00:00",
"db": "VULMON",
"id": "CVE-2020-15836"
},
{
"date": "2021-02-03T20:07:08.993000",
"db": "NVD",
"id": "CVE-2020-15836"
},
{
"date": "2021-02-09T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202101-2601"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202101-2601"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Mofi Network MOFI4500-4GXeLTE unauthorized RCE vulnerability",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13964"
}
],
"trust": 0.6
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "other",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202101-2601"
}
],
"trust": 0.6
}
}
VAR-202102-0158
Vulnerability from variot - Updated: 2023-12-18 13:51An issue was discovered on Mofi Network MOFI4500-4GXeLTE 4.1.5-std devices. The wireless network password is exposed in a QR encoded picture that an unauthenticated adversary can download via the web-management interface. Mofi Network MOFI4500-4GXeLTE is a wireless router of Mofi Network Company. Attackers can use this vulnerability to access /wifi.png to obtain the QR code of the Wi-Fi password
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202102-0158",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "mofi4500-4gxelte",
"scope": "eq",
"trust": 1.0,
"vendor": "mofinetwork",
"version": "4.1.5-std"
},
{
"model": "network mofi4500-4gxelte 4.1.5-std",
"scope": null,
"trust": 0.6,
"vendor": "mofi",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13966"
},
{
"db": "NVD",
"id": "CVE-2020-15834"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:mofinetwork:mofi4500-4gxelte_firmware:4.1.5-std:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:mofinetwork:mofi4500-4gxelte:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2020-15834"
}
]
},
"cve": "CVE-2020-15834",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"integrityImpact": "NONE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CNVD-2021-13966",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULMON",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CVE-2020-15834",
"impactScore": 2.9,
"integrityImpact": "NONE",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "MEDIUM",
"trust": 0.1,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2020-15834",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2021-13966",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-202101-2610",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULMON",
"id": "CVE-2020-15834",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13966"
},
{
"db": "VULMON",
"id": "CVE-2020-15834"
},
{
"db": "NVD",
"id": "CVE-2020-15834"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2610"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "An issue was discovered on Mofi Network MOFI4500-4GXeLTE 4.1.5-std devices. The wireless network password is exposed in a QR encoded picture that an unauthenticated adversary can download via the web-management interface. Mofi Network MOFI4500-4GXeLTE is a wireless router of Mofi Network Company. Attackers can use this vulnerability to access /wifi.png to obtain the QR code of the Wi-Fi password",
"sources": [
{
"db": "NVD",
"id": "CVE-2020-15834"
},
{
"db": "CNVD",
"id": "CNVD-2021-13966"
},
{
"db": "VULMON",
"id": "CVE-2020-15834"
}
],
"trust": 1.53
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2020-15834",
"trust": 2.3
},
{
"db": "CNVD",
"id": "CNVD-2021-13966",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2610",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2020-15834",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13966"
},
{
"db": "VULMON",
"id": "CVE-2020-15834"
},
{
"db": "NVD",
"id": "CVE-2020-15834"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2610"
}
]
},
"id": "VAR-202102-0158",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13966"
}
],
"trust": 1.6
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13966"
}
]
},
"last_update_date": "2023-12-18T13:51:37.287000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Mofi Network MOFI4500-4GXeLTE Unauthorized Information Disclosure Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/250466"
},
{
"title": "Mofi Network MOFI4500-4GXeLTE Repair measures for information disclosure vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=140641"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13966"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2610"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-306",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2020-15834"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.7,
"url": "https://mofinetwork.com/index.php?main_page=page\u0026id=14"
},
{
"trust": 1.7,
"url": "https://www.criticalstart.com/critical-vulnerabilities-discovered-in-mofi-routers/"
},
{
"trust": 1.2,
"url": "https://nvd.nist.gov/vuln/detail/cve-2020-15834"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/200.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13966"
},
{
"db": "VULMON",
"id": "CVE-2020-15834"
},
{
"db": "NVD",
"id": "CVE-2020-15834"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2610"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2021-13966"
},
{
"db": "VULMON",
"id": "CVE-2020-15834"
},
{
"db": "NVD",
"id": "CVE-2020-15834"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2610"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-03-03T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-13966"
},
{
"date": "2021-02-01T00:00:00",
"db": "VULMON",
"id": "CVE-2020-15834"
},
{
"date": "2021-02-01T02:15:15.050000",
"db": "NVD",
"id": "CVE-2020-15834"
},
{
"date": "2021-01-31T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202101-2610"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-08-19T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-13966"
},
{
"date": "2021-02-04T00:00:00",
"db": "VULMON",
"id": "CVE-2020-15834"
},
{
"date": "2021-07-21T11:39:23.747000",
"db": "NVD",
"id": "CVE-2020-15834"
},
{
"date": "2021-02-09T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202101-2610"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202101-2610"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Mofi Network MOFI4500-4GXeLTE Unauthorized Information Disclosure Vulnerability",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13966"
}
],
"trust": 0.6
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "information disclosure",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202101-2610"
}
],
"trust": 0.6
}
}
VAR-202102-0098
Vulnerability from variot - Updated: 2023-12-18 13:51An issue was discovered on Mofi Network MOFI4500-4GXeLTE 4.0.8-std devices. Authentication is not required to download the support file that contains sensitive information such as cleartext credentials and password hashes. Mofi Network MOFI4500-4GXeLTE is a wireless router of Mofi Network Company. Attackers can use this leak to gain unauthorized access to /systemlog.tar.gz to obtain information such as /etc/shadow and plaintext Wi-Fi credentials
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202102-0098",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "mofi4500-4gxelte",
"scope": "eq",
"trust": 1.0,
"vendor": "mofinetwork",
"version": "4.0.8-std"
},
{
"model": "network mofi4500-4gxelte 4.0.8-std",
"scope": null,
"trust": 0.6,
"vendor": "mofi",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13973"
},
{
"db": "NVD",
"id": "CVE-2020-13856"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:mofinetwork:mofi4500-4gxelte_firmware:4.0.8-std:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:mofinetwork:mofi4500-4gxelte:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2020-13856"
}
]
},
"cve": "CVE-2020-13856",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"integrityImpact": "NONE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CNVD-2021-13973",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULMON",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CVE-2020-13856",
"impactScore": 2.9,
"integrityImpact": "NONE",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "MEDIUM",
"trust": 0.1,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2020-13856",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2021-13973",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-202101-2602",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULMON",
"id": "CVE-2020-13856",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13973"
},
{
"db": "VULMON",
"id": "CVE-2020-13856"
},
{
"db": "NVD",
"id": "CVE-2020-13856"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2602"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "An issue was discovered on Mofi Network MOFI4500-4GXeLTE 4.0.8-std devices. Authentication is not required to download the support file that contains sensitive information such as cleartext credentials and password hashes. Mofi Network MOFI4500-4GXeLTE is a wireless router of Mofi Network Company. Attackers can use this leak to gain unauthorized access to /systemlog.tar.gz to obtain information such as /etc/shadow and plaintext Wi-Fi credentials",
"sources": [
{
"db": "NVD",
"id": "CVE-2020-13856"
},
{
"db": "CNVD",
"id": "CNVD-2021-13973"
},
{
"db": "VULMON",
"id": "CVE-2020-13856"
}
],
"trust": 1.53
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2020-13856",
"trust": 2.3
},
{
"db": "CNVD",
"id": "CNVD-2021-13973",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2602",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2020-13856",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13973"
},
{
"db": "VULMON",
"id": "CVE-2020-13856"
},
{
"db": "NVD",
"id": "CVE-2020-13856"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2602"
}
]
},
"id": "VAR-202102-0098",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13973"
}
],
"trust": 1.6
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13973"
}
]
},
"last_update_date": "2023-12-18T13:51:37.386000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Mofi Network MOFI4500-4GXeLTE Unauthorized Information Disclosure Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/250436"
},
{
"title": "Mofi Network MOFI4500-4GXeLTE Security vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=140634"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13973"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2602"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-306",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2020-13856"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.7,
"url": "https://mofinetwork.com/index.php?main_page=page\u0026id=14"
},
{
"trust": 1.7,
"url": "https://www.criticalstart.com/critical-vulnerabilities-discovered-in-mofi-routers/"
},
{
"trust": 1.2,
"url": "https://nvd.nist.gov/vuln/detail/cve-2020-13856"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/522.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13973"
},
{
"db": "VULMON",
"id": "CVE-2020-13856"
},
{
"db": "NVD",
"id": "CVE-2020-13856"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2602"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2021-13973"
},
{
"db": "VULMON",
"id": "CVE-2020-13856"
},
{
"db": "NVD",
"id": "CVE-2020-13856"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2602"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-03-03T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-13973"
},
{
"date": "2021-02-01T00:00:00",
"db": "VULMON",
"id": "CVE-2020-13856"
},
{
"date": "2021-02-01T02:15:12.517000",
"db": "NVD",
"id": "CVE-2020-13856"
},
{
"date": "2021-01-31T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202101-2602"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-08-19T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-13973"
},
{
"date": "2021-02-03T00:00:00",
"db": "VULMON",
"id": "CVE-2020-13856"
},
{
"date": "2021-07-21T11:39:23.747000",
"db": "NVD",
"id": "CVE-2020-13856"
},
{
"date": "2021-02-09T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202101-2602"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202101-2602"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Mofi Network MOFI4500-4GXeLTE Unauthorized Information Disclosure Vulnerability",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13973"
}
],
"trust": 0.6
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "other",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202101-2602"
}
],
"trust": 0.6
}
}
VAR-202102-0159
Vulnerability from variot - Updated: 2023-12-18 13:37An issue was discovered on Mofi Network MOFI4500-4GXeLTE 4.1.5-std devices. The authentication function contains undocumented code that provides the ability to authenticate as root without knowing the actual root password. An adversary with the private key can remotely authenticate to the management interface as root. Mofi Network MOFI4500-4GXeLTE is a wireless router of Mofi Network Company
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202102-0159",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "mofi4500-4gxelte",
"scope": "eq",
"trust": 1.0,
"vendor": "mofinetwork",
"version": "4.1.5-std"
},
{
"model": "network mofi4500-4gxelte 4.1.5-std",
"scope": null,
"trust": 0.6,
"vendor": "mofi",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13965"
},
{
"db": "NVD",
"id": "CVE-2020-15835"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:mofinetwork:mofi4500-4gxelte_firmware:4.1.5-std:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:mofinetwork:mofi4500-4gxelte:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2020-15835"
}
]
},
"cve": "CVE-2020-15835",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2021-13965",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULMON",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CVE-2020-15835",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "HIGH",
"trust": 0.1,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2020-15835",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "CNVD",
"id": "CNVD-2021-13965",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202101-2611",
"trust": 0.6,
"value": "CRITICAL"
},
{
"author": "VULMON",
"id": "CVE-2020-15835",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13965"
},
{
"db": "VULMON",
"id": "CVE-2020-15835"
},
{
"db": "NVD",
"id": "CVE-2020-15835"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2611"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "An issue was discovered on Mofi Network MOFI4500-4GXeLTE 4.1.5-std devices. The authentication function contains undocumented code that provides the ability to authenticate as root without knowing the actual root password. An adversary with the private key can remotely authenticate to the management interface as root. Mofi Network MOFI4500-4GXeLTE is a wireless router of Mofi Network Company",
"sources": [
{
"db": "NVD",
"id": "CVE-2020-15835"
},
{
"db": "CNVD",
"id": "CNVD-2021-13965"
},
{
"db": "VULMON",
"id": "CVE-2020-15835"
}
],
"trust": 1.53
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2020-15835",
"trust": 2.3
},
{
"db": "CNVD",
"id": "CNVD-2021-13965",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2611",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2020-15835",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13965"
},
{
"db": "VULMON",
"id": "CVE-2020-15835"
},
{
"db": "NVD",
"id": "CVE-2020-15835"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2611"
}
]
},
"id": "VAR-202102-0159",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13965"
}
],
"trust": 1.6
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13965"
}
]
},
"last_update_date": "2023-12-18T13:37:34.266000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Mofi Network MOFI4500-4GXeLTE certification bypass vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/250471"
},
{
"title": "Mofi Network MOFI4500-4GXeLTE Remediation measures for authorization problem vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=140642"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13965"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2611"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-287",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2020-15835"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.7,
"url": "https://mofinetwork.com/index.php?main_page=page\u0026id=14"
},
{
"trust": 1.7,
"url": "https://www.criticalstart.com/critical-vulnerabilities-discovered-in-mofi-routers/"
},
{
"trust": 1.2,
"url": "https://nvd.nist.gov/vuln/detail/cve-2020-15835"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/287.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13965"
},
{
"db": "VULMON",
"id": "CVE-2020-15835"
},
{
"db": "NVD",
"id": "CVE-2020-15835"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2611"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2021-13965"
},
{
"db": "VULMON",
"id": "CVE-2020-15835"
},
{
"db": "NVD",
"id": "CVE-2020-15835"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2611"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-03-03T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-13965"
},
{
"date": "2021-02-01T00:00:00",
"db": "VULMON",
"id": "CVE-2020-15835"
},
{
"date": "2021-02-01T02:15:15.160000",
"db": "NVD",
"id": "CVE-2020-15835"
},
{
"date": "2021-01-31T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202101-2611"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-03-03T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-13965"
},
{
"date": "2021-02-03T00:00:00",
"db": "VULMON",
"id": "CVE-2020-15835"
},
{
"date": "2021-02-03T20:45:42.523000",
"db": "NVD",
"id": "CVE-2020-15835"
},
{
"date": "2021-02-09T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202101-2611"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202101-2611"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Mofi Network MOFI4500-4GXeLTE certification bypass vulnerability",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13965"
}
],
"trust": 0.6
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "authorization issue",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202101-2611"
}
],
"trust": 0.6
}
}
VAR-202102-0101
Vulnerability from variot - Updated: 2023-12-18 13:27An issue was discovered on Mofi Network MOFI4500-4GXeLTE 4.0.8-std devices. A format error in /etc/shadow, coupled with a logic bug in the LuCI - OpenWrt Configuration Interface framework, allows the undocumented system account mofidev to login to the cgi-bin/luci/quick/wizard management interface without a password by abusing a forgotten-password feature. Mofi Network MOFI4500-4GXeLTE is a wireless router of Mofi Network Company. Attackers can use the vulnerabilities to log in to the mofidev user with any password. After logging in, the root user's password can be modified
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202102-0101",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "mofi4500-4gxelte",
"scope": "eq",
"trust": 1.0,
"vendor": "mofinetwork",
"version": "4.0.8-std"
},
{
"model": "network mofi4500-4gxelte 4.0.8-std",
"scope": null,
"trust": 0.6,
"vendor": "mofi",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13970"
},
{
"db": "NVD",
"id": "CVE-2020-13859"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:mofinetwork:mofi4500-4gxelte_firmware:4.0.8-std:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:mofinetwork:mofi4500-4gxelte:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2020-13859"
}
]
},
"cve": "CVE-2020-13859",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"integrityImpact": "NONE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CNVD-2021-13970",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULMON",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CVE-2020-13859",
"impactScore": 2.9,
"integrityImpact": "NONE",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "MEDIUM",
"trust": 0.1,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2020-13859",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "CNVD",
"id": "CNVD-2021-13970",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-202101-2606",
"trust": 0.6,
"value": "CRITICAL"
},
{
"author": "VULMON",
"id": "CVE-2020-13859",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13970"
},
{
"db": "VULMON",
"id": "CVE-2020-13859"
},
{
"db": "NVD",
"id": "CVE-2020-13859"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2606"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "An issue was discovered on Mofi Network MOFI4500-4GXeLTE 4.0.8-std devices. A format error in /etc/shadow, coupled with a logic bug in the LuCI - OpenWrt Configuration Interface framework, allows the undocumented system account mofidev to login to the cgi-bin/luci/quick/wizard management interface without a password by abusing a forgotten-password feature. Mofi Network MOFI4500-4GXeLTE is a wireless router of Mofi Network Company. Attackers can use the vulnerabilities to log in to the mofidev user with any password. After logging in, the root user\u0027s password can be modified",
"sources": [
{
"db": "NVD",
"id": "CVE-2020-13859"
},
{
"db": "CNVD",
"id": "CNVD-2021-13970"
},
{
"db": "VULMON",
"id": "CVE-2020-13859"
}
],
"trust": 1.53
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2020-13859",
"trust": 2.3
},
{
"db": "CNVD",
"id": "CNVD-2021-13970",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2606",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2020-13859",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13970"
},
{
"db": "VULMON",
"id": "CVE-2020-13859"
},
{
"db": "NVD",
"id": "CVE-2020-13859"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2606"
}
]
},
"id": "VAR-202102-0101",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13970"
}
],
"trust": 1.6
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13970"
}
]
},
"last_update_date": "2023-12-18T13:27:50.466000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Mofi Network MOFI-GXeLTE certification bypass vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/250446"
},
{
"title": "Mofi Network MOFI-GXeLTE Security vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=140637"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13970"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2606"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-287",
"trust": 1.0
},
{
"problemtype": "CWE-755",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2020-13859"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.7,
"url": "https://mofinetwork.com/index.php?main_page=page\u0026id=14"
},
{
"trust": 1.7,
"url": "https://www.criticalstart.com/critical-vulnerabilities-discovered-in-mofi-routers/"
},
{
"trust": 1.2,
"url": "https://nvd.nist.gov/vuln/detail/cve-2020-13859"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/522.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13970"
},
{
"db": "VULMON",
"id": "CVE-2020-13859"
},
{
"db": "NVD",
"id": "CVE-2020-13859"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2606"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2021-13970"
},
{
"db": "VULMON",
"id": "CVE-2020-13859"
},
{
"db": "NVD",
"id": "CVE-2020-13859"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2606"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-03-02T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-13970"
},
{
"date": "2021-02-01T00:00:00",
"db": "VULMON",
"id": "CVE-2020-13859"
},
{
"date": "2021-02-01T02:15:14.800000",
"db": "NVD",
"id": "CVE-2020-13859"
},
{
"date": "2021-01-31T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202101-2606"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-03-03T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-13970"
},
{
"date": "2021-02-04T00:00:00",
"db": "VULMON",
"id": "CVE-2020-13859"
},
{
"date": "2021-07-21T11:39:23.747000",
"db": "NVD",
"id": "CVE-2020-13859"
},
{
"date": "2021-02-09T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202101-2606"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202101-2606"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Mofi Network MOFI-GXeLTE certification bypass vulnerability",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13970"
}
],
"trust": 0.6
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "other",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202101-2606"
}
],
"trust": 0.6
}
}
VAR-202102-0102
Vulnerability from variot - Updated: 2023-12-18 13:12An issue was discovered on Mofi Network MOFI4500-4GXeLTE 4.0.8-std devices. The one-time password algorithm for the undocumented system account mofidev generates a predictable six-digit password. Mofi Network MOFI4500-4GXeLTE is a wireless router of Mofi Network Company. Attackers can use this vulnerability to know its generation algorithm through firmware reverse engineering, and directly calculate a one-time password based on the PIN code
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202102-0102",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "mofi4500-4gxelte",
"scope": "eq",
"trust": 1.0,
"vendor": "mofinetwork",
"version": "4.0.8-std"
},
{
"model": "network mofi4500-4gxelte 4.0.8-std",
"scope": null,
"trust": 0.6,
"vendor": "mofi",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13969"
},
{
"db": "NVD",
"id": "CVE-2020-13860"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:mofinetwork:mofi4500-4gxelte_firmware:4.0.8-std:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:mofinetwork:mofi4500-4gxelte:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2020-13860"
}
]
},
"cve": "CVE-2020-13860",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"integrityImpact": "NONE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CNVD-2021-13969",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULMON",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CVE-2020-13860",
"impactScore": 2.9,
"integrityImpact": "NONE",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "MEDIUM",
"trust": 0.1,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2020-13860",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2021-13969",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-202101-2607",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULMON",
"id": "CVE-2020-13860",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13969"
},
{
"db": "VULMON",
"id": "CVE-2020-13860"
},
{
"db": "NVD",
"id": "CVE-2020-13860"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2607"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "An issue was discovered on Mofi Network MOFI4500-4GXeLTE 4.0.8-std devices. The one-time password algorithm for the undocumented system account mofidev generates a predictable six-digit password. Mofi Network MOFI4500-4GXeLTE is a wireless router of Mofi Network Company. Attackers can use this vulnerability to know its generation algorithm through firmware reverse engineering, and directly calculate a one-time password based on the PIN code",
"sources": [
{
"db": "NVD",
"id": "CVE-2020-13860"
},
{
"db": "CNVD",
"id": "CNVD-2021-13969"
},
{
"db": "VULMON",
"id": "CVE-2020-13860"
}
],
"trust": 1.53
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2020-13860",
"trust": 2.3
},
{
"db": "CNVD",
"id": "CNVD-2021-13969",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2607",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2020-13860",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13969"
},
{
"db": "VULMON",
"id": "CVE-2020-13860"
},
{
"db": "NVD",
"id": "CVE-2020-13860"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2607"
}
]
},
"id": "VAR-202102-0102",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13969"
}
],
"trust": 1.6
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13969"
}
]
},
"last_update_date": "2023-12-18T13:12:40.343000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Mofi Network MOFI4500-4GXeLTE security feature issue vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/250451"
},
{
"title": "Mofi Network MOFI4500-4GXeLTE Fixing measures for security feature vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=140638"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13969"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2607"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-330",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2020-13860"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.7,
"url": "https://mofinetwork.com/index.php?main_page=page\u0026id=14"
},
{
"trust": 1.7,
"url": "https://www.criticalstart.com/critical-vulnerabilities-discovered-in-mofi-routers/"
},
{
"trust": 1.2,
"url": "https://nvd.nist.gov/vuln/detail/cve-2020-13860"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/330.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13969"
},
{
"db": "VULMON",
"id": "CVE-2020-13860"
},
{
"db": "NVD",
"id": "CVE-2020-13860"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2607"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2021-13969"
},
{
"db": "VULMON",
"id": "CVE-2020-13860"
},
{
"db": "NVD",
"id": "CVE-2020-13860"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2607"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-03-03T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-13969"
},
{
"date": "2021-02-01T00:00:00",
"db": "VULMON",
"id": "CVE-2020-13860"
},
{
"date": "2021-02-01T02:15:14.847000",
"db": "NVD",
"id": "CVE-2020-13860"
},
{
"date": "2021-01-31T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202101-2607"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-03-03T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-13969"
},
{
"date": "2021-02-04T00:00:00",
"db": "VULMON",
"id": "CVE-2020-13860"
},
{
"date": "2021-02-04T15:41:33.337000",
"db": "NVD",
"id": "CVE-2020-13860"
},
{
"date": "2021-02-09T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202101-2607"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202101-2607"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Mofi Network MOFI4500-4GXeLTE security feature issue vulnerability",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13969"
}
],
"trust": 0.6
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "security feature problem",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202101-2607"
}
],
"trust": 0.6
}
}
VAR-202102-0099
Vulnerability from variot - Updated: 2023-12-18 12:42An issue was discovered on Mofi Network MOFI4500-4GXeLTE 3.6.1-std and 4.0.8-std devices. They can be rebooted by sending an unauthenticated poof.cgi HTTP GET request. Mofi Network MOFI4500-4GXeLTE is a wireless router of Mofi Network Company. Attackers can use this vulnerability to access /cgi-bin/poof.cgi to remotely restart the device
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202102-0099",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "mofi4500-4gxelte",
"scope": "eq",
"trust": 1.0,
"vendor": "mofinetwork",
"version": "4.0.8-std"
},
{
"model": "mofi4500-4gxelte",
"scope": "eq",
"trust": 1.0,
"vendor": "mofinetwork",
"version": "4.1.5-std"
},
{
"model": "mofi4500-4gxelte",
"scope": "eq",
"trust": 1.0,
"vendor": "mofinetwork",
"version": "3.6.1-std"
},
{
"model": "network mofi4500-4gxelte 3.6.1-std",
"scope": null,
"trust": 0.6,
"vendor": "mofi",
"version": null
},
{
"model": "network mofi4500-4gxelte 4.0.8-std",
"scope": null,
"trust": 0.6,
"vendor": "mofi",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13972"
},
{
"db": "NVD",
"id": "CVE-2020-13857"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:mofinetwork:mofi4500-4gxelte_firmware:3.6.1-std:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:mofinetwork:mofi4500-4gxelte_firmware:4.0.8-std:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:mofinetwork:mofi4500-4gxelte_firmware:4.1.5-std:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:mofinetwork:mofi4500-4gxelte:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2020-13857"
}
]
},
"cve": "CVE-2020-13857",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"impactScore": 6.9,
"integrityImpact": "NONE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2021-13972",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULMON",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CVE-2020-13857",
"impactScore": 6.9,
"integrityImpact": "NONE",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "HIGH",
"trust": 0.1,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2020-13857",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2021-13972",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202101-2604",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULMON",
"id": "CVE-2020-13857",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13972"
},
{
"db": "VULMON",
"id": "CVE-2020-13857"
},
{
"db": "NVD",
"id": "CVE-2020-13857"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2604"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "An issue was discovered on Mofi Network MOFI4500-4GXeLTE 3.6.1-std and 4.0.8-std devices. They can be rebooted by sending an unauthenticated poof.cgi HTTP GET request. Mofi Network MOFI4500-4GXeLTE is a wireless router of Mofi Network Company. Attackers can use this vulnerability to access /cgi-bin/poof.cgi to remotely restart the device",
"sources": [
{
"db": "NVD",
"id": "CVE-2020-13857"
},
{
"db": "CNVD",
"id": "CNVD-2021-13972"
},
{
"db": "VULMON",
"id": "CVE-2020-13857"
}
],
"trust": 1.53
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2020-13857",
"trust": 2.3
},
{
"db": "CNVD",
"id": "CNVD-2021-13972",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2604",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2020-13857",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13972"
},
{
"db": "VULMON",
"id": "CVE-2020-13857"
},
{
"db": "NVD",
"id": "CVE-2020-13857"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2604"
}
]
},
"id": "VAR-202102-0099",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13972"
}
],
"trust": 1.6
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13972"
}
]
},
"last_update_date": "2023-12-18T12:42:36.758000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Mofi Network MOFI4500-4GXeLTE Unauthorized remote restart patch",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/250441"
},
{
"title": "Mofi Network MOFI4500-4GXeLTE Security vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=140635"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13972"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2604"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "NVD-CWE-noinfo",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2020-13857"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.7,
"url": "https://mofinetwork.com/index.php?main_page=page\u0026id=14"
},
{
"trust": 1.7,
"url": "https://www.criticalstart.com/critical-vulnerabilities-discovered-in-mofi-routers/"
},
{
"trust": 1.2,
"url": "https://nvd.nist.gov/vuln/detail/cve-2020-13857"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13972"
},
{
"db": "VULMON",
"id": "CVE-2020-13857"
},
{
"db": "NVD",
"id": "CVE-2020-13857"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2604"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2021-13972"
},
{
"db": "VULMON",
"id": "CVE-2020-13857"
},
{
"db": "NVD",
"id": "CVE-2020-13857"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2604"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-03-03T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-13972"
},
{
"date": "2021-02-01T00:00:00",
"db": "VULMON",
"id": "CVE-2020-13857"
},
{
"date": "2021-02-01T02:15:13.707000",
"db": "NVD",
"id": "CVE-2020-13857"
},
{
"date": "2021-01-31T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202101-2604"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-04-06T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-13972"
},
{
"date": "2021-02-04T00:00:00",
"db": "VULMON",
"id": "CVE-2020-13857"
},
{
"date": "2021-02-04T15:42:21.200000",
"db": "NVD",
"id": "CVE-2020-13857"
},
{
"date": "2021-02-09T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202101-2604"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202101-2604"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Mofi Network MOFI4500-4GXeLTE Unauthorized Remote Restart Vulnerability",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13972"
}
],
"trust": 0.6
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "other",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202101-2604"
}
],
"trust": 0.6
}
}
VAR-202102-0157
Vulnerability from variot - Updated: 2023-12-18 12:35An issue was discovered on Mofi Network MOFI4500-4GXeLTE 4.1.5-std devices. The Dropbear SSH daemon has been modified to accept an alternate hard-coded path to a public key that allows root access. This key is stored in a /rom location that cannot be modified by the device owner. Mofi Network MOFI4500-4GXeLTE is a wireless router of Mofi Network Company
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202102-0157",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "mofi4500-4gxelte",
"scope": "eq",
"trust": 1.0,
"vendor": "mofinetwork",
"version": "4.1.5-std"
},
{
"model": "network mofi4500-4gxelte 4.1.5-std",
"scope": null,
"trust": 0.6,
"vendor": "mofi",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13967"
},
{
"db": "NVD",
"id": "CVE-2020-15833"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:mofinetwork:mofi4500-4gxelte_firmware:4.1.5-std:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:mofinetwork:mofi4500-4gxelte:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2020-15833"
}
]
},
"cve": "CVE-2020-15833",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2021-13967",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULMON",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CVE-2020-15833",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "HIGH",
"trust": 0.1,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2020-15833",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "CNVD",
"id": "CNVD-2021-13967",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202101-2609",
"trust": 0.6,
"value": "CRITICAL"
},
{
"author": "VULMON",
"id": "CVE-2020-15833",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13967"
},
{
"db": "VULMON",
"id": "CVE-2020-15833"
},
{
"db": "NVD",
"id": "CVE-2020-15833"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2609"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "An issue was discovered on Mofi Network MOFI4500-4GXeLTE 4.1.5-std devices. The Dropbear SSH daemon has been modified to accept an alternate hard-coded path to a public key that allows root access. This key is stored in a /rom location that cannot be modified by the device owner. Mofi Network MOFI4500-4GXeLTE is a wireless router of Mofi Network Company",
"sources": [
{
"db": "NVD",
"id": "CVE-2020-15833"
},
{
"db": "CNVD",
"id": "CNVD-2021-13967"
},
{
"db": "VULMON",
"id": "CVE-2020-15833"
}
],
"trust": 1.53
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2020-15833",
"trust": 2.3
},
{
"db": "CNVD",
"id": "CNVD-2021-13967",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2609",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2020-15833",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13967"
},
{
"db": "VULMON",
"id": "CVE-2020-15833"
},
{
"db": "NVD",
"id": "CVE-2020-15833"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2609"
}
]
},
"id": "VAR-202102-0157",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13967"
}
],
"trust": 1.6
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13967"
}
]
},
"last_update_date": "2023-12-18T12:35:10.480000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Mofi Network MOFI4500-4GXeLTE backdoor vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/250461"
},
{
"title": "Mofi Network MOFI4500-4GXeLTE Repair measures for trust management problem vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=140640"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13967"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2609"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-798",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2020-15833"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.7,
"url": "https://mofinetwork.com/index.php?main_page=page\u0026id=14"
},
{
"trust": 1.7,
"url": "https://www.criticalstart.com/critical-vulnerabilities-discovered-in-mofi-routers/"
},
{
"trust": 1.2,
"url": "https://nvd.nist.gov/vuln/detail/cve-2020-15833"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/798.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13967"
},
{
"db": "VULMON",
"id": "CVE-2020-15833"
},
{
"db": "NVD",
"id": "CVE-2020-15833"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2609"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2021-13967"
},
{
"db": "VULMON",
"id": "CVE-2020-15833"
},
{
"db": "NVD",
"id": "CVE-2020-15833"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2609"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-03-03T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-13967"
},
{
"date": "2021-02-01T00:00:00",
"db": "VULMON",
"id": "CVE-2020-15833"
},
{
"date": "2021-02-01T02:15:14.987000",
"db": "NVD",
"id": "CVE-2020-15833"
},
{
"date": "2021-01-31T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202101-2609"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-03-03T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-13967"
},
{
"date": "2021-02-04T00:00:00",
"db": "VULMON",
"id": "CVE-2020-15833"
},
{
"date": "2021-02-04T15:23:34.747000",
"db": "NVD",
"id": "CVE-2020-15833"
},
{
"date": "2021-02-09T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202101-2609"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202101-2609"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Mofi Network MOFI4500-4GXeLTE backdoor vulnerability",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13967"
}
],
"trust": 0.6
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "trust management problem",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202101-2609"
}
],
"trust": 0.6
}
}
VAR-202102-0100
Vulnerability from variot - Updated: 2023-12-18 12:16An issue was discovered on Mofi Network MOFI4500-4GXeLTE 3.6.1-std and 4.0.8-std devices. They contain two undocumented administrator accounts. The sftp and mofidev accounts are defined in /etc/passwd and the password is not unique across installations. Mofi Network MOFI4500-4GXeLTE is a wireless router of Mofi Network Company. No detailed vulnerability details are currently provided
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202102-0100",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "mofi4500-4gxelte",
"scope": "eq",
"trust": 1.0,
"vendor": "mofinetwork",
"version": "4.0.8-std"
},
{
"model": "mofi4500-4gxelte",
"scope": "eq",
"trust": 1.0,
"vendor": "mofinetwork",
"version": "3.6.1-std"
},
{
"model": "network mofi4500-4gxelte 3.6.1-std",
"scope": null,
"trust": 0.6,
"vendor": "mofi",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13971"
},
{
"db": "NVD",
"id": "CVE-2020-13858"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:mofinetwork:mofi4500-4gxelte_firmware:3.6.1-std:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:mofinetwork:mofi4500-4gxelte_firmware:4.0.8-std:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:mofinetwork:mofi4500-4gxelte:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2020-13858"
}
]
},
"cve": "CVE-2020-13858",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CNVD-2021-13971",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULMON",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CVE-2020-13858",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "HIGH",
"trust": 0.1,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2020-13858",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "CNVD",
"id": "CNVD-2021-13971",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202101-2605",
"trust": 0.6,
"value": "CRITICAL"
},
{
"author": "VULMON",
"id": "CVE-2020-13858",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13971"
},
{
"db": "VULMON",
"id": "CVE-2020-13858"
},
{
"db": "NVD",
"id": "CVE-2020-13858"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2605"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "An issue was discovered on Mofi Network MOFI4500-4GXeLTE 3.6.1-std and 4.0.8-std devices. They contain two undocumented administrator accounts. The sftp and mofidev accounts are defined in /etc/passwd and the password is not unique across installations. Mofi Network MOFI4500-4GXeLTE is a wireless router of Mofi Network Company. No detailed vulnerability details are currently provided",
"sources": [
{
"db": "NVD",
"id": "CVE-2020-13858"
},
{
"db": "CNVD",
"id": "CNVD-2021-13971"
},
{
"db": "VULMON",
"id": "CVE-2020-13858"
}
],
"trust": 1.53
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2020-13858",
"trust": 2.3
},
{
"db": "CNVD",
"id": "CNVD-2021-13971",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2605",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2020-13858",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13971"
},
{
"db": "VULMON",
"id": "CVE-2020-13858"
},
{
"db": "NVD",
"id": "CVE-2020-13858"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2605"
}
]
},
"id": "VAR-202102-0100",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13971"
}
],
"trust": 1.6
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13971"
}
]
},
"last_update_date": "2023-12-18T12:16:38Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Mofi Network MOFI4500-4GXeLTE has unspecified vulnerabilities",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/250481"
},
{
"title": "Mofi Network MOFI4500-4GXeLTE Repair measures for trust management problem vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=140636"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13971"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2605"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-798",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2020-13858"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.7,
"url": "https://mofinetwork.com/index.php?main_page=page\u0026id=14"
},
{
"trust": 1.7,
"url": "https://www.criticalstart.com/critical-vulnerabilities-discovered-in-mofi-routers/"
},
{
"trust": 1.2,
"url": "https://nvd.nist.gov/vuln/detail/cve-2020-13858"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/798.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13971"
},
{
"db": "VULMON",
"id": "CVE-2020-13858"
},
{
"db": "NVD",
"id": "CVE-2020-13858"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2605"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2021-13971"
},
{
"db": "VULMON",
"id": "CVE-2020-13858"
},
{
"db": "NVD",
"id": "CVE-2020-13858"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2605"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-03-03T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-13971"
},
{
"date": "2021-02-01T00:00:00",
"db": "VULMON",
"id": "CVE-2020-13858"
},
{
"date": "2021-02-01T02:15:14.707000",
"db": "NVD",
"id": "CVE-2020-13858"
},
{
"date": "2021-01-31T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202101-2605"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-03-03T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-13971"
},
{
"date": "2021-02-03T00:00:00",
"db": "VULMON",
"id": "CVE-2020-13858"
},
{
"date": "2021-02-03T20:40:43.923000",
"db": "NVD",
"id": "CVE-2020-13858"
},
{
"date": "2021-02-09T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202101-2605"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202101-2605"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Mofi Network MOFI4500-4GXeLTE has unspecified vulnerabilities",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13971"
}
],
"trust": 0.6
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "trust management problem",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202101-2605"
}
],
"trust": 0.6
}
}
VAR-202102-0156
Vulnerability from variot - Updated: 2023-12-18 11:57An issue was discovered on Mofi Network MOFI4500-4GXeLTE 4.1.5-std devices. The poof.cgi script contains undocumented code that provides the ability to remotely reboot the device. An adversary with the private key (but not the root password) can remotely reboot the device. Mofi Network MOFI4500-4GXeLTE is a wireless router of Mofi Network Company
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202102-0156",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "mofi4500-4gxelte",
"scope": "eq",
"trust": 1.0,
"vendor": "mofinetwork",
"version": "4.1.5-std"
},
{
"model": "network mofi4500-4gxelte 4.1.5-std",
"scope": null,
"trust": 0.6,
"vendor": "mofi",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13968"
},
{
"db": "NVD",
"id": "CVE-2020-15832"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:mofinetwork:mofi4500-4gxelte_firmware:4.1.5-std:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:mofinetwork:mofi4500-4gxelte:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2020-15832"
}
]
},
"cve": "CVE-2020-15832",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"impactScore": 6.9,
"integrityImpact": "NONE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2021-13968",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULMON",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CVE-2020-15832",
"impactScore": 6.9,
"integrityImpact": "NONE",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "HIGH",
"trust": 0.1,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2020-15832",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2021-13968",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202101-2608",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULMON",
"id": "CVE-2020-15832",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13968"
},
{
"db": "VULMON",
"id": "CVE-2020-15832"
},
{
"db": "NVD",
"id": "CVE-2020-15832"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2608"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "An issue was discovered on Mofi Network MOFI4500-4GXeLTE 4.1.5-std devices. The poof.cgi script contains undocumented code that provides the ability to remotely reboot the device. An adversary with the private key (but not the root password) can remotely reboot the device. Mofi Network MOFI4500-4GXeLTE is a wireless router of Mofi Network Company",
"sources": [
{
"db": "NVD",
"id": "CVE-2020-15832"
},
{
"db": "CNVD",
"id": "CNVD-2021-13968"
},
{
"db": "VULMON",
"id": "CVE-2020-15832"
}
],
"trust": 1.53
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2020-15832",
"trust": 2.3
},
{
"db": "CNVD",
"id": "CNVD-2021-13968",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2608",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2020-15832",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13968"
},
{
"db": "VULMON",
"id": "CVE-2020-15832"
},
{
"db": "NVD",
"id": "CVE-2020-15832"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2608"
}
]
},
"id": "VAR-202102-0156",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13968"
}
],
"trust": 1.6
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13968"
}
]
},
"last_update_date": "2023-12-18T11:57:38.704000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Mofi Network MOFI4500-4GXeLTE remote restart backdoor vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/250456"
},
{
"title": "Mofi Network MOFI4500-4GXeLTE Security vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=140639"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13968"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2608"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "NVD-CWE-noinfo",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2020-15832"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.7,
"url": "https://mofinetwork.com/index.php?main_page=page\u0026id=14"
},
{
"trust": 1.7,
"url": "https://www.criticalstart.com/critical-vulnerabilities-discovered-in-mofi-routers/"
},
{
"trust": 1.2,
"url": "https://nvd.nist.gov/vuln/detail/cve-2020-15832"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13968"
},
{
"db": "VULMON",
"id": "CVE-2020-15832"
},
{
"db": "NVD",
"id": "CVE-2020-15832"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2608"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2021-13968"
},
{
"db": "VULMON",
"id": "CVE-2020-15832"
},
{
"db": "NVD",
"id": "CVE-2020-15832"
},
{
"db": "CNNVD",
"id": "CNNVD-202101-2608"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-03-03T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-13968"
},
{
"date": "2021-02-01T00:00:00",
"db": "VULMON",
"id": "CVE-2020-15832"
},
{
"date": "2021-02-01T02:15:14.927000",
"db": "NVD",
"id": "CVE-2020-15832"
},
{
"date": "2021-01-31T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202101-2608"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-03-03T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-13968"
},
{
"date": "2021-02-04T00:00:00",
"db": "VULMON",
"id": "CVE-2020-15832"
},
{
"date": "2021-02-04T15:36:48.533000",
"db": "NVD",
"id": "CVE-2020-15832"
},
{
"date": "2021-02-09T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202101-2608"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202101-2608"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Mofi Network MOFI4500-4GXeLTE remote restart backdoor vulnerability",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-13968"
}
],
"trust": 0.6
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "other",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202101-2608"
}
],
"trust": 0.6
}
}