    CVE-2018-12456 (GCVE-0-2018-12456)

    Vulnerability from cvelistv5 – Published: 2018-10-10 21:00 – Updated: 2024-08-05 08:38
    VLAI
    Summary
    Intelbras NPLUG 1.0.0.14 wireless repeater devices have no CSRF token protection in the web interface, allowing attackers to perform actions such as changing the wireless SSID, rebooting the device, editing access control lists, or activating remote access.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    URL Tags
    http://seclists.org/fulldisclosure/2018/Oct/18 mailing-listx_refsource_FULLDISC
    Date Public
    2018-10-08 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T08:38:05.688Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "20181008 Multiple vulnerabilities in NPLUG wireless repeater",
                "tags": [
                  "mailing-list",
                  "x_refsource_FULLDISC",
                  "x_transferred"
                ],
                "url": "http://seclists.org/fulldisclosure/2018/Oct/18"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2018-10-08T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Intelbras NPLUG 1.0.0.14 wireless repeater devices have no CSRF token protection in the web interface, allowing attackers to perform actions such as changing the wireless SSID, rebooting the device, editing access control lists, or activating remote access."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-10-10T20:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "name": "20181008 Multiple vulnerabilities in NPLUG wireless repeater",
              "tags": [
                "mailing-list",
                "x_refsource_FULLDISC"
              ],
              "url": "http://seclists.org/fulldisclosure/2018/Oct/18"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-12456",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Intelbras NPLUG 1.0.0.14 wireless repeater devices have no CSRF token protection in the web interface, allowing attackers to perform actions such as changing the wireless SSID, rebooting the device, editing access control lists, or activating remote access."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "20181008 Multiple vulnerabilities in NPLUG wireless repeater",
                  "refsource": "FULLDISC",
                  "url": "http://seclists.org/fulldisclosure/2018/Oct/18"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-12456",
        "datePublished": "2018-10-10T21:00:00.000Z",
        "dateReserved": "2018-06-15T00:00:00.000Z",
        "dateUpdated": "2024-08-05T08:38:05.688Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-17337 (GCVE-0-2018-17337)

    Vulnerability from cvelistv5 – Published: 2018-10-10 21:00 – Updated: 2024-08-05 10:47
    VLAI
    Summary
    Intelbras NPLUG 1.0.0.14 devices have XSS via a crafted SSID that is received via a network broadcast.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    URL Tags
    http://seclists.org/fulldisclosure/2018/Oct/18 mailing-listx_refsource_FULLDISC
    Date Public
    2018-10-08 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T10:47:04.327Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "20181008 Multiple vulnerabilities in NPLUG wireless repeater",
                "tags": [
                  "mailing-list",
                  "x_refsource_FULLDISC",
                  "x_transferred"
                ],
                "url": "http://seclists.org/fulldisclosure/2018/Oct/18"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2018-10-08T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Intelbras NPLUG 1.0.0.14 devices have XSS via a crafted SSID that is received via a network broadcast."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-10-10T20:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "name": "20181008 Multiple vulnerabilities in NPLUG wireless repeater",
              "tags": [
                "mailing-list",
                "x_refsource_FULLDISC"
              ],
              "url": "http://seclists.org/fulldisclosure/2018/Oct/18"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-17337",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Intelbras NPLUG 1.0.0.14 devices have XSS via a crafted SSID that is received via a network broadcast."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "20181008 Multiple vulnerabilities in NPLUG wireless repeater",
                  "refsource": "FULLDISC",
                  "url": "http://seclists.org/fulldisclosure/2018/Oct/18"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-17337",
        "datePublished": "2018-10-10T21:00:00.000Z",
        "dateReserved": "2018-09-22T00:00:00.000Z",
        "dateUpdated": "2024-08-05T10:47:04.327Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-12455 (GCVE-0-2018-12455)

    Vulnerability from cvelistv5 – Published: 2018-10-10 21:00 – Updated: 2024-08-05 08:38
    VLAI
    Summary
    Intelbras NPLUG 1.0.0.14 wireless repeater devices have a critical vulnerability that allows an attacker to authenticate in the web interface just by using "admin:" as the name of a cookie.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    URL Tags
    http://seclists.org/fulldisclosure/2018/Oct/18 mailing-listx_refsource_FULLDISC
    Date Public
    2018-10-08 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T08:38:05.954Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "20181008 Multiple vulnerabilities in NPLUG wireless repeater",
                "tags": [
                  "mailing-list",
                  "x_refsource_FULLDISC",
                  "x_transferred"
                ],
                "url": "http://seclists.org/fulldisclosure/2018/Oct/18"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2018-10-08T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Intelbras NPLUG 1.0.0.14 wireless repeater devices have a critical vulnerability that allows an attacker to authenticate in the web interface just by using \"admin:\" as the name of a cookie."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-10-10T20:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "name": "20181008 Multiple vulnerabilities in NPLUG wireless repeater",
              "tags": [
                "mailing-list",
                "x_refsource_FULLDISC"
              ],
              "url": "http://seclists.org/fulldisclosure/2018/Oct/18"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-12455",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Intelbras NPLUG 1.0.0.14 wireless repeater devices have a critical vulnerability that allows an attacker to authenticate in the web interface just by using \"admin:\" as the name of a cookie."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "20181008 Multiple vulnerabilities in NPLUG wireless repeater",
                  "refsource": "FULLDISC",
                  "url": "http://seclists.org/fulldisclosure/2018/Oct/18"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-12455",
        "datePublished": "2018-10-10T21:00:00.000Z",
        "dateReserved": "2018-06-15T00:00:00.000Z",
        "dateUpdated": "2024-08-05T08:38:05.954Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-12456 (GCVE-0-2018-12456)

    Vulnerability from nvd – Published: 2018-10-10 21:00 – Updated: 2024-08-05 08:38
    VLAI
    Summary
    Intelbras NPLUG 1.0.0.14 wireless repeater devices have no CSRF token protection in the web interface, allowing attackers to perform actions such as changing the wireless SSID, rebooting the device, editing access control lists, or activating remote access.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    URL Tags
    http://seclists.org/fulldisclosure/2018/Oct/18 mailing-listx_refsource_FULLDISC
    Date Public
    2018-10-08 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T08:38:05.688Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "20181008 Multiple vulnerabilities in NPLUG wireless repeater",
                "tags": [
                  "mailing-list",
                  "x_refsource_FULLDISC",
                  "x_transferred"
                ],
                "url": "http://seclists.org/fulldisclosure/2018/Oct/18"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2018-10-08T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Intelbras NPLUG 1.0.0.14 wireless repeater devices have no CSRF token protection in the web interface, allowing attackers to perform actions such as changing the wireless SSID, rebooting the device, editing access control lists, or activating remote access."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-10-10T20:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "name": "20181008 Multiple vulnerabilities in NPLUG wireless repeater",
              "tags": [
                "mailing-list",
                "x_refsource_FULLDISC"
              ],
              "url": "http://seclists.org/fulldisclosure/2018/Oct/18"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-12456",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Intelbras NPLUG 1.0.0.14 wireless repeater devices have no CSRF token protection in the web interface, allowing attackers to perform actions such as changing the wireless SSID, rebooting the device, editing access control lists, or activating remote access."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "20181008 Multiple vulnerabilities in NPLUG wireless repeater",
                  "refsource": "FULLDISC",
                  "url": "http://seclists.org/fulldisclosure/2018/Oct/18"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-12456",
        "datePublished": "2018-10-10T21:00:00.000Z",
        "dateReserved": "2018-06-15T00:00:00.000Z",
        "dateUpdated": "2024-08-05T08:38:05.688Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-17337 (GCVE-0-2018-17337)

    Vulnerability from nvd – Published: 2018-10-10 21:00 – Updated: 2024-08-05 10:47
    VLAI
    Summary
    Intelbras NPLUG 1.0.0.14 devices have XSS via a crafted SSID that is received via a network broadcast.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    URL Tags
    http://seclists.org/fulldisclosure/2018/Oct/18 mailing-listx_refsource_FULLDISC
    Date Public
    2018-10-08 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T10:47:04.327Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "20181008 Multiple vulnerabilities in NPLUG wireless repeater",
                "tags": [
                  "mailing-list",
                  "x_refsource_FULLDISC",
                  "x_transferred"
                ],
                "url": "http://seclists.org/fulldisclosure/2018/Oct/18"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2018-10-08T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Intelbras NPLUG 1.0.0.14 devices have XSS via a crafted SSID that is received via a network broadcast."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-10-10T20:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "name": "20181008 Multiple vulnerabilities in NPLUG wireless repeater",
              "tags": [
                "mailing-list",
                "x_refsource_FULLDISC"
              ],
              "url": "http://seclists.org/fulldisclosure/2018/Oct/18"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-17337",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Intelbras NPLUG 1.0.0.14 devices have XSS via a crafted SSID that is received via a network broadcast."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "20181008 Multiple vulnerabilities in NPLUG wireless repeater",
                  "refsource": "FULLDISC",
                  "url": "http://seclists.org/fulldisclosure/2018/Oct/18"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-17337",
        "datePublished": "2018-10-10T21:00:00.000Z",
        "dateReserved": "2018-09-22T00:00:00.000Z",
        "dateUpdated": "2024-08-05T10:47:04.327Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-12455 (GCVE-0-2018-12455)

    Vulnerability from nvd – Published: 2018-10-10 21:00 – Updated: 2024-08-05 08:38
    VLAI
    Summary
    Intelbras NPLUG 1.0.0.14 wireless repeater devices have a critical vulnerability that allows an attacker to authenticate in the web interface just by using "admin:" as the name of a cookie.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    URL Tags
    http://seclists.org/fulldisclosure/2018/Oct/18 mailing-listx_refsource_FULLDISC
    Date Public
    2018-10-08 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T08:38:05.954Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "20181008 Multiple vulnerabilities in NPLUG wireless repeater",
                "tags": [
                  "mailing-list",
                  "x_refsource_FULLDISC",
                  "x_transferred"
                ],
                "url": "http://seclists.org/fulldisclosure/2018/Oct/18"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2018-10-08T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Intelbras NPLUG 1.0.0.14 wireless repeater devices have a critical vulnerability that allows an attacker to authenticate in the web interface just by using \"admin:\" as the name of a cookie."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-10-10T20:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "name": "20181008 Multiple vulnerabilities in NPLUG wireless repeater",
              "tags": [
                "mailing-list",
                "x_refsource_FULLDISC"
              ],
              "url": "http://seclists.org/fulldisclosure/2018/Oct/18"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-12455",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Intelbras NPLUG 1.0.0.14 wireless repeater devices have a critical vulnerability that allows an attacker to authenticate in the web interface just by using \"admin:\" as the name of a cookie."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "20181008 Multiple vulnerabilities in NPLUG wireless repeater",
                  "refsource": "FULLDISC",
                  "url": "http://seclists.org/fulldisclosure/2018/Oct/18"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-12455",
        "datePublished": "2018-10-10T21:00:00.000Z",
        "dateReserved": "2018-06-15T00:00:00.000Z",
        "dateUpdated": "2024-08-05T08:38:05.954Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }