Search criteria
6 vulnerabilities found for ns_series_system_program_firmware by omron
FKIE_CVE-2014-2369
Vulnerability from fkie_nvd - Published: 2014-07-24 14:55 - Updated: 2025-10-06 18:15
Severity ?
Summary
Cross-site request forgery (CSRF) vulnerability in the web application on Omron NS5, NS8, NS10, NS12, and NS15 HMI terminals 8.1xx through 8.68x allows remote authenticated users to hijack the authentication of unspecified victims via unknown vectors.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| omron | ns_series_system_program_firmware | 8.1 | |
| omron | ns_series_system_program_firmware | 8.68 | |
| omron | ns10_hmi_terminal | - | |
| omron | ns12_hmi_terminal | - | |
| omron | ns15_hmi_terminal | - | |
| omron | ns5_hmi_terminal | - | |
| omron | ns8_hmi_terminal | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:omron:ns_series_system_program_firmware:8.1:*:*:*:*:*:*:*",
"matchCriteriaId": "8246BB5A-986B-4AA0-B3A2-645976E8E7AF",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:omron:ns_series_system_program_firmware:8.68:*:*:*:*:*:*:*",
"matchCriteriaId": "58C930D1-BA9F-4643-8321-B160A018C5D9",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:omron:ns10_hmi_terminal:-:*:*:*:*:*:*:*",
"matchCriteriaId": "31B221BA-8C11-41E2-836A-3007022AB5DE",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:omron:ns12_hmi_terminal:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6E804153-AE32-4FE1-920F-FF648A2B2FE0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:omron:ns15_hmi_terminal:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F78DF368-D063-42D2-ABD4-ABD63BF22842",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:omron:ns5_hmi_terminal:-:*:*:*:*:*:*:*",
"matchCriteriaId": "076C5660-3EBF-4318-B3C6-BF28596EB99E",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:omron:ns8_hmi_terminal:-:*:*:*:*:*:*:*",
"matchCriteriaId": "112E9FC7-96BB-4E5F-8697-8E0E48A80914",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Cross-site request forgery (CSRF) vulnerability in the web application on Omron NS5, NS8, NS10, NS12, and NS15 HMI terminals 8.1xx through 8.68x allows remote authenticated users to hijack the authentication of unspecified victims via unknown vectors."
},
{
"lang": "es",
"value": "Vulnerabilidad de CSRF en la aplicaci\u00f3n web en los terminales HMI Omron NS5, NS8, NS10, NS12 y NS15 8.1xx hasta 8.68x permite a usuarios remotos autenticados secuestrar la autenticaci\u00f3n de victimas no especificadas a trav\u00e9s de vectores desconocidos."
}
],
"id": "CVE-2014-2369",
"lastModified": "2025-10-06T18:15:48.690",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "HIGH",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "PARTIAL",
"baseScore": 4.6,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:H/Au:S/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 3.9,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary",
"userInteractionRequired": true
},
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "PARTIAL",
"baseScore": 6.0,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:S/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 6.8,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
]
},
"published": "2014-07-24T14:55:07.287",
"references": [
{
"source": "ics-cert@hq.dhs.gov",
"url": "https://automation.omron.com/en/us/products/"
},
{
"source": "ics-cert@hq.dhs.gov",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-14-203-01"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-203-01"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-352"
}
],
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-352"
}
],
"source": "nvd@nist.gov",
"type": "Secondary"
}
]
}
FKIE_CVE-2014-2370
Vulnerability from fkie_nvd - Published: 2014-07-24 14:55 - Updated: 2025-10-06 18:15
Severity ?
Summary
Cross-site scripting (XSS) vulnerability in the web application on Omron NS5, NS8, NS10, NS12, and NS15 HMI terminals 8.1xx through 8.68x allows remote authenticated users to inject arbitrary web script or HTML via crafted data.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| omron | ns_series_system_program_firmware | 8.1 | |
| omron | ns_series_system_program_firmware | 8.68 | |
| omron | ns10_hmi_terminal | - | |
| omron | ns12_hmi_terminal | - | |
| omron | ns15_hmi_terminal | - | |
| omron | ns5_hmi_terminal | - | |
| omron | ns8_hmi_terminal | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:omron:ns_series_system_program_firmware:8.1:*:*:*:*:*:*:*",
"matchCriteriaId": "8246BB5A-986B-4AA0-B3A2-645976E8E7AF",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:omron:ns_series_system_program_firmware:8.68:*:*:*:*:*:*:*",
"matchCriteriaId": "58C930D1-BA9F-4643-8321-B160A018C5D9",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:omron:ns10_hmi_terminal:-:*:*:*:*:*:*:*",
"matchCriteriaId": "31B221BA-8C11-41E2-836A-3007022AB5DE",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:omron:ns12_hmi_terminal:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6E804153-AE32-4FE1-920F-FF648A2B2FE0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:omron:ns15_hmi_terminal:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F78DF368-D063-42D2-ABD4-ABD63BF22842",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:omron:ns5_hmi_terminal:-:*:*:*:*:*:*:*",
"matchCriteriaId": "076C5660-3EBF-4318-B3C6-BF28596EB99E",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:omron:ns8_hmi_terminal:-:*:*:*:*:*:*:*",
"matchCriteriaId": "112E9FC7-96BB-4E5F-8697-8E0E48A80914",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Cross-site scripting (XSS) vulnerability in the web application on Omron NS5, NS8, NS10, NS12, and NS15 HMI terminals 8.1xx through 8.68x allows remote authenticated users to inject arbitrary web script or HTML via crafted data."
},
{
"lang": "es",
"value": "Vulnerabilidad de XSS en la aplicaci\u00f3n web en los terminales HMI Omron NS5, NS8, NS10, NS12 y NS15 8.1xx hasta 8.68x permite a usuarios remotos autenticados inyectar secuencias de comandos web o HTML arbitrarios a trav\u00e9s de datos manipulados."
}
],
"id": "CVE-2014-2370",
"lastModified": "2025-10-06T18:15:48.843",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "NONE",
"baseScore": 4.0,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:S/C:N/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary",
"userInteractionRequired": true
},
{
"acInsufInfo": false,
"baseSeverity": "LOW",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "NONE",
"baseScore": 3.5,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 6.8,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
]
},
"published": "2014-07-24T14:55:07.317",
"references": [
{
"source": "ics-cert@hq.dhs.gov",
"url": "https://automation.omron.com/en/us/products/"
},
{
"source": "ics-cert@hq.dhs.gov",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-14-203-01"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-203-01"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "http://www.securityfocus.com/bid/68836"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "nvd@nist.gov",
"type": "Secondary"
}
]
}
CVE-2014-2369 (GCVE-0-2014-2369)
Vulnerability from cvelistv5 – Published: 2014-07-24 14:00 – Updated: 2025-10-06 17:59
VLAI?
Title
Omron NS Series HMI Cross-Site Request Forgery
Summary
Cross-site request forgery (CSRF) vulnerability in the web application on Omron NS5, NS8, NS10, NS12, and NS15 HMI terminals 8.1xx through 8.68x allows remote authenticated users to hijack the authentication of unspecified victims via unknown vectors.
Severity ?
No CVSS data available.
CWE
Assigner
References
Impacted products
Credits
Joel Sevilleja Febrer of S2 Grupo
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T10:14:25.244Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-203-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "NS15",
"vendor": "Omron",
"versions": [
{
"lessThan": "8.68x",
"status": "affected",
"version": "8.1xx",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "NS12",
"vendor": "Omron",
"versions": [
{
"lessThan": "8.68x",
"status": "affected",
"version": "8.1xx",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "NS10",
"vendor": "Omron",
"versions": [
{
"lessThan": "8.68x",
"status": "affected",
"version": "8.1xx",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "NS8",
"vendor": "Omron",
"versions": [
{
"lessThan": "8.68x",
"status": "affected",
"version": "8.1xx",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "NS5",
"vendor": "Omron",
"versions": [
{
"lessThan": "8.68x",
"status": "affected",
"version": "8.1xx",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Joel Sevilleja Febrer of S2 Grupo"
}
],
"datePublic": "2014-07-22T06:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eCross-site request forgery (CSRF) vulnerability in the web application on Omron NS5, NS8, NS10, NS12, and NS15 HMI terminals 8.1xx through 8.68x allows remote authenticated users to hijack the authentication of unspecified victims via unknown vectors.\u003c/p\u003e"
}
],
"value": "Cross-site request forgery (CSRF) vulnerability in the web application on Omron NS5, NS8, NS10, NS12, and NS15 HMI terminals 8.1xx through 8.68x allows remote authenticated users to hijack the authentication of unspecified victims via unknown vectors."
}
],
"metrics": [
{
"cvssV2_0": {
"accessComplexity": "HIGH",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "PARTIAL",
"baseScore": 4.6,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:H/Au:S/C:P/I:P/A:P",
"version": "2.0"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-352",
"description": "CWE-352",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-06T17:59:20.171Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-14-203-01"
},
{
"url": "https://automation.omron.com/en/us/products/"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eOmron Corporation has produced update, Version 8.69x for Japan and \nVersion 8.7x for other countries, that mitigates the identified \nvulnerabilities. The updates for the NS series of HMI terminals can be \ndownloaded at the following locations:\u003c/p\u003e\n\u003cp\u003eNS15 Software Update Version 8.7:\u003c/p\u003e\n\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns15/default.html\"\u003ehttp://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns15/default.html\u003c/a\u003e\u003c/p\u003e\u003cp\u003eNS12 Software Update Version 8.7:\u003c/p\u003e\n\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns12/default.html\"\u003ehttp://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns12/default.html\u003c/a\u003e\u003c/p\u003e\u003cp\u003eNS10 Software Update Version 8.7:\u003c/p\u003e\n\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns10/default.html\"\u003ehttp://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns10/default.html\u003c/a\u003e\u003c/p\u003e\u003cp\u003eNS8 Software Update Version 8.7:\u003c/p\u003e\n\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns8/default.html\"\u003ehttp://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns8/default.html\u003c/a\u003e\u003c/p\u003e\u003cp\u003eNS5 Software Update Version 8.7:\u003c/p\u003e\n\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns5/default.html\"\u003ehttp://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns5/default.html\u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e"
}
],
"value": "Omron Corporation has produced update, Version 8.69x for Japan and \nVersion 8.7x for other countries, that mitigates the identified \nvulnerabilities. The updates for the NS series of HMI terminals can be \ndownloaded at the following locations:\n\n\nNS15 Software Update Version 8.7:\n\n\n http://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns15/default.html \n\nNS12 Software Update Version 8.7:\n\n\n http://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns12/default.html \n\nNS10 Software Update Version 8.7:\n\n\n http://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns10/default.html \n\nNS8 Software Update Version 8.7:\n\n\n http://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns8/default.html \n\nNS5 Software Update Version 8.7:\n\n\n http://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns5/default.html"
}
],
"source": {
"advisory": "ICSA-14-203-01",
"discovery": "UNKNOWN"
},
"title": "Omron NS Series HMI Cross-Site Request Forgery",
"x_generator": {
"engine": "Vulnogram 0.2.0"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2014-2369",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Cross-site request forgery (CSRF) vulnerability in the web application on Omron NS5, NS8, NS10, NS12, and NS15 HMI terminals 8.1xx through 8.68x allows remote authenticated users to hijack the authentication of unspecified victims via unknown vectors."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://ics-cert.us-cert.gov/advisories/ICSA-14-203-01",
"refsource": "MISC",
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-203-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2014-2369",
"datePublished": "2014-07-24T14:00:00",
"dateReserved": "2014-03-13T00:00:00",
"dateUpdated": "2025-10-06T17:59:20.171Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2014-2370 (GCVE-0-2014-2370)
Vulnerability from cvelistv5 – Published: 2014-07-24 14:00 – Updated: 2025-10-06 18:01
VLAI?
Title
Omron NS Series HMI Improper Neutralization of Input During Web Page Generation
Summary
Cross-site scripting (XSS) vulnerability in the web application on Omron NS5, NS8, NS10, NS12, and NS15 HMI terminals 8.1xx through 8.68x allows remote authenticated users to inject arbitrary web script or HTML via crafted data.
Severity ?
No CVSS data available.
CWE
Assigner
References
Impacted products
Credits
Joel Sevilleja Febrer of S2 Grupo
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T10:14:25.880Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-203-01"
},
{
"name": "68836",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/68836"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "NS15",
"vendor": "Omron",
"versions": [
{
"lessThan": "8.68x",
"status": "affected",
"version": "8.1xx",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "NS12",
"vendor": "Omron",
"versions": [
{
"lessThan": "8.68x",
"status": "affected",
"version": "8.1xx",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "NS10",
"vendor": "Omron",
"versions": [
{
"lessThan": "8.68x",
"status": "affected",
"version": "8.1xx",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "NS8",
"vendor": "Omron",
"versions": [
{
"lessThan": "8.68x",
"status": "affected",
"version": "8.1xx",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "NS5",
"vendor": "Omron",
"versions": [
{
"lessThan": "8.68x",
"status": "affected",
"version": "8.1xx",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Joel Sevilleja Febrer of S2 Grupo"
}
],
"datePublic": "2014-07-22T06:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003e\nCross-site scripting (XSS) vulnerability in the web application on Omron NS5, NS8, NS10, NS12, and NS15 HMI terminals 8.1xx through 8.68x allows remote authenticated users to inject arbitrary web script or HTML via crafted data.\n\n\u003c/p\u003e"
}
],
"value": "Cross-site scripting (XSS) vulnerability in the web application on Omron NS5, NS8, NS10, NS12, and NS15 HMI terminals 8.1xx through 8.68x allows remote authenticated users to inject arbitrary web script or HTML via crafted data."
}
],
"metrics": [
{
"cvssV2_0": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "NONE",
"baseScore": 4,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:S/C:N/I:P/A:N",
"version": "2.0"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-06T18:01:21.608Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-14-203-01"
},
{
"url": "https://automation.omron.com/en/us/products/"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eOmron Corporation has produced update, Version 8.69x for Japan and \nVersion 8.7x for other countries, that mitigates the identified \nvulnerabilities. The updates for the NS series of HMI terminals can be \ndownloaded at the following locations:\u003c/p\u003e\n\u003cp\u003eNS15 Software Update Version 8.7:\u003c/p\u003e\n\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns15/default.html\"\u003ehttp://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns15/default.html\u003c/a\u003e\u003c/p\u003e\u003cp\u003eNS12 Software Update Version 8.7:\u003c/p\u003e\n\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns12/default.html\"\u003ehttp://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns12/default.html\u003c/a\u003e\u003c/p\u003e\u003cp\u003eNS10 Software Update Version 8.7:\u003c/p\u003e\n\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns10/default.html\"\u003ehttp://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns10/default.html\u003c/a\u003e\u003c/p\u003e\u003cp\u003eNS8 Software Update Version 8.7:\u003c/p\u003e\n\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns8/default.html\"\u003ehttp://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns8/default.html\u003c/a\u003e\u003c/p\u003e\u003cp\u003eNS5 Software Update Version 8.7:\u003c/p\u003e\n\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns5/default.html\"\u003ehttp://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns5/default.html\u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e"
}
],
"value": "Omron Corporation has produced update, Version 8.69x for Japan and \nVersion 8.7x for other countries, that mitigates the identified \nvulnerabilities. The updates for the NS series of HMI terminals can be \ndownloaded at the following locations:\n\n\nNS15 Software Update Version 8.7:\n\n\n http://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns15/default.html \n\nNS12 Software Update Version 8.7:\n\n\n http://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns12/default.html \n\nNS10 Software Update Version 8.7:\n\n\n http://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns10/default.html \n\nNS8 Software Update Version 8.7:\n\n\n http://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns8/default.html \n\nNS5 Software Update Version 8.7:\n\n\n http://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns5/default.html"
}
],
"source": {
"advisory": "ICSA-14-203-01",
"discovery": "EXTERNAL"
},
"title": "Omron NS Series HMI Improper Neutralization of Input During Web Page Generation",
"x_generator": {
"engine": "Vulnogram 0.2.0"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2014-2369",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Cross-site request forgery (CSRF) vulnerability in the web application on Omron NS5, NS8, NS10, NS12, and NS15 HMI terminals 8.1xx through 8.68x allows remote authenticated users to hijack the authentication of unspecified victims via unknown vectors."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://ics-cert.us-cert.gov/advisories/ICSA-14-203-01",
"refsource": "MISC",
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-203-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2014-2370",
"datePublished": "2014-07-24T14:00:00",
"dateReserved": "2014-03-13T00:00:00",
"dateUpdated": "2025-10-06T18:01:21.608Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2014-2369 (GCVE-0-2014-2369)
Vulnerability from nvd – Published: 2014-07-24 14:00 – Updated: 2025-10-06 17:59
VLAI?
Title
Omron NS Series HMI Cross-Site Request Forgery
Summary
Cross-site request forgery (CSRF) vulnerability in the web application on Omron NS5, NS8, NS10, NS12, and NS15 HMI terminals 8.1xx through 8.68x allows remote authenticated users to hijack the authentication of unspecified victims via unknown vectors.
Severity ?
No CVSS data available.
CWE
Assigner
References
Impacted products
Credits
Joel Sevilleja Febrer of S2 Grupo
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T10:14:25.244Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-203-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "NS15",
"vendor": "Omron",
"versions": [
{
"lessThan": "8.68x",
"status": "affected",
"version": "8.1xx",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "NS12",
"vendor": "Omron",
"versions": [
{
"lessThan": "8.68x",
"status": "affected",
"version": "8.1xx",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "NS10",
"vendor": "Omron",
"versions": [
{
"lessThan": "8.68x",
"status": "affected",
"version": "8.1xx",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "NS8",
"vendor": "Omron",
"versions": [
{
"lessThan": "8.68x",
"status": "affected",
"version": "8.1xx",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "NS5",
"vendor": "Omron",
"versions": [
{
"lessThan": "8.68x",
"status": "affected",
"version": "8.1xx",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Joel Sevilleja Febrer of S2 Grupo"
}
],
"datePublic": "2014-07-22T06:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eCross-site request forgery (CSRF) vulnerability in the web application on Omron NS5, NS8, NS10, NS12, and NS15 HMI terminals 8.1xx through 8.68x allows remote authenticated users to hijack the authentication of unspecified victims via unknown vectors.\u003c/p\u003e"
}
],
"value": "Cross-site request forgery (CSRF) vulnerability in the web application on Omron NS5, NS8, NS10, NS12, and NS15 HMI terminals 8.1xx through 8.68x allows remote authenticated users to hijack the authentication of unspecified victims via unknown vectors."
}
],
"metrics": [
{
"cvssV2_0": {
"accessComplexity": "HIGH",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "PARTIAL",
"baseScore": 4.6,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:H/Au:S/C:P/I:P/A:P",
"version": "2.0"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-352",
"description": "CWE-352",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-06T17:59:20.171Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-14-203-01"
},
{
"url": "https://automation.omron.com/en/us/products/"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eOmron Corporation has produced update, Version 8.69x for Japan and \nVersion 8.7x for other countries, that mitigates the identified \nvulnerabilities. The updates for the NS series of HMI terminals can be \ndownloaded at the following locations:\u003c/p\u003e\n\u003cp\u003eNS15 Software Update Version 8.7:\u003c/p\u003e\n\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns15/default.html\"\u003ehttp://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns15/default.html\u003c/a\u003e\u003c/p\u003e\u003cp\u003eNS12 Software Update Version 8.7:\u003c/p\u003e\n\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns12/default.html\"\u003ehttp://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns12/default.html\u003c/a\u003e\u003c/p\u003e\u003cp\u003eNS10 Software Update Version 8.7:\u003c/p\u003e\n\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns10/default.html\"\u003ehttp://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns10/default.html\u003c/a\u003e\u003c/p\u003e\u003cp\u003eNS8 Software Update Version 8.7:\u003c/p\u003e\n\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns8/default.html\"\u003ehttp://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns8/default.html\u003c/a\u003e\u003c/p\u003e\u003cp\u003eNS5 Software Update Version 8.7:\u003c/p\u003e\n\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns5/default.html\"\u003ehttp://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns5/default.html\u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e"
}
],
"value": "Omron Corporation has produced update, Version 8.69x for Japan and \nVersion 8.7x for other countries, that mitigates the identified \nvulnerabilities. The updates for the NS series of HMI terminals can be \ndownloaded at the following locations:\n\n\nNS15 Software Update Version 8.7:\n\n\n http://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns15/default.html \n\nNS12 Software Update Version 8.7:\n\n\n http://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns12/default.html \n\nNS10 Software Update Version 8.7:\n\n\n http://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns10/default.html \n\nNS8 Software Update Version 8.7:\n\n\n http://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns8/default.html \n\nNS5 Software Update Version 8.7:\n\n\n http://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns5/default.html"
}
],
"source": {
"advisory": "ICSA-14-203-01",
"discovery": "UNKNOWN"
},
"title": "Omron NS Series HMI Cross-Site Request Forgery",
"x_generator": {
"engine": "Vulnogram 0.2.0"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2014-2369",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Cross-site request forgery (CSRF) vulnerability in the web application on Omron NS5, NS8, NS10, NS12, and NS15 HMI terminals 8.1xx through 8.68x allows remote authenticated users to hijack the authentication of unspecified victims via unknown vectors."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://ics-cert.us-cert.gov/advisories/ICSA-14-203-01",
"refsource": "MISC",
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-203-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2014-2369",
"datePublished": "2014-07-24T14:00:00",
"dateReserved": "2014-03-13T00:00:00",
"dateUpdated": "2025-10-06T17:59:20.171Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2014-2370 (GCVE-0-2014-2370)
Vulnerability from nvd – Published: 2014-07-24 14:00 – Updated: 2025-10-06 18:01
VLAI?
Title
Omron NS Series HMI Improper Neutralization of Input During Web Page Generation
Summary
Cross-site scripting (XSS) vulnerability in the web application on Omron NS5, NS8, NS10, NS12, and NS15 HMI terminals 8.1xx through 8.68x allows remote authenticated users to inject arbitrary web script or HTML via crafted data.
Severity ?
No CVSS data available.
CWE
Assigner
References
Impacted products
Credits
Joel Sevilleja Febrer of S2 Grupo
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T10:14:25.880Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-203-01"
},
{
"name": "68836",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/68836"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "NS15",
"vendor": "Omron",
"versions": [
{
"lessThan": "8.68x",
"status": "affected",
"version": "8.1xx",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "NS12",
"vendor": "Omron",
"versions": [
{
"lessThan": "8.68x",
"status": "affected",
"version": "8.1xx",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "NS10",
"vendor": "Omron",
"versions": [
{
"lessThan": "8.68x",
"status": "affected",
"version": "8.1xx",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "NS8",
"vendor": "Omron",
"versions": [
{
"lessThan": "8.68x",
"status": "affected",
"version": "8.1xx",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "NS5",
"vendor": "Omron",
"versions": [
{
"lessThan": "8.68x",
"status": "affected",
"version": "8.1xx",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Joel Sevilleja Febrer of S2 Grupo"
}
],
"datePublic": "2014-07-22T06:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003e\nCross-site scripting (XSS) vulnerability in the web application on Omron NS5, NS8, NS10, NS12, and NS15 HMI terminals 8.1xx through 8.68x allows remote authenticated users to inject arbitrary web script or HTML via crafted data.\n\n\u003c/p\u003e"
}
],
"value": "Cross-site scripting (XSS) vulnerability in the web application on Omron NS5, NS8, NS10, NS12, and NS15 HMI terminals 8.1xx through 8.68x allows remote authenticated users to inject arbitrary web script or HTML via crafted data."
}
],
"metrics": [
{
"cvssV2_0": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "NONE",
"baseScore": 4,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:S/C:N/I:P/A:N",
"version": "2.0"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-06T18:01:21.608Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-14-203-01"
},
{
"url": "https://automation.omron.com/en/us/products/"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eOmron Corporation has produced update, Version 8.69x for Japan and \nVersion 8.7x for other countries, that mitigates the identified \nvulnerabilities. The updates for the NS series of HMI terminals can be \ndownloaded at the following locations:\u003c/p\u003e\n\u003cp\u003eNS15 Software Update Version 8.7:\u003c/p\u003e\n\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns15/default.html\"\u003ehttp://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns15/default.html\u003c/a\u003e\u003c/p\u003e\u003cp\u003eNS12 Software Update Version 8.7:\u003c/p\u003e\n\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns12/default.html\"\u003ehttp://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns12/default.html\u003c/a\u003e\u003c/p\u003e\u003cp\u003eNS10 Software Update Version 8.7:\u003c/p\u003e\n\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns10/default.html\"\u003ehttp://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns10/default.html\u003c/a\u003e\u003c/p\u003e\u003cp\u003eNS8 Software Update Version 8.7:\u003c/p\u003e\n\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns8/default.html\"\u003ehttp://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns8/default.html\u003c/a\u003e\u003c/p\u003e\u003cp\u003eNS5 Software Update Version 8.7:\u003c/p\u003e\n\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns5/default.html\"\u003ehttp://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns5/default.html\u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e"
}
],
"value": "Omron Corporation has produced update, Version 8.69x for Japan and \nVersion 8.7x for other countries, that mitigates the identified \nvulnerabilities. The updates for the NS series of HMI terminals can be \ndownloaded at the following locations:\n\n\nNS15 Software Update Version 8.7:\n\n\n http://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns15/default.html \n\nNS12 Software Update Version 8.7:\n\n\n http://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns12/default.html \n\nNS10 Software Update Version 8.7:\n\n\n http://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns10/default.html \n\nNS8 Software Update Version 8.7:\n\n\n http://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns8/default.html \n\nNS5 Software Update Version 8.7:\n\n\n http://industrial.omron.us/en/products/catalogue/automation_systems/hmi/scalable_hmi/ns5/default.html"
}
],
"source": {
"advisory": "ICSA-14-203-01",
"discovery": "EXTERNAL"
},
"title": "Omron NS Series HMI Improper Neutralization of Input During Web Page Generation",
"x_generator": {
"engine": "Vulnogram 0.2.0"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2014-2369",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Cross-site request forgery (CSRF) vulnerability in the web application on Omron NS5, NS8, NS10, NS12, and NS15 HMI terminals 8.1xx through 8.68x allows remote authenticated users to hijack the authentication of unspecified victims via unknown vectors."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://ics-cert.us-cert.gov/advisories/ICSA-14-203-01",
"refsource": "MISC",
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-203-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2014-2370",
"datePublished": "2014-07-24T14:00:00",
"dateReserved": "2014-03-13T00:00:00",
"dateUpdated": "2025-10-06T18:01:21.608Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}